AE601 Signage Schedule Stripping and Details.pdf

PDF 1 MB Posted

Attached to
Veterans Affairs, Parking Expansion, Columbia, SC
Solicitation number
W912HP21R4003
Issued by

About this file

This document package includes construction drawings and details for signage, striping, and parking space layout for the Veterans Affairs parking expansion project in Columbia, South Carolina. The drawings specify requirements for parking space and directional striping, signage types and locations by floor level, and details for wall-mounted, hanging, and post-installed signs. Sign content and style must comply with VA guidelines. Proposals are due no later than May 3, 2021 for the solicitation issued by the Department of the Army Corps of Engineers Charleston District for the parking expansion at the Columbia VA facility.

View the file

Other files

File Type Posted
D.03 Award Notice 21C4000 8.30.21.pdf PDF
B.08 Memorandum Amendment 0005 21R4003 5.20.21.pdf PDF
B.08 Amendment 0005 21R4003 5.20.21.pdf PDF
A.02 Amendment 0005 09 54 23 - Linear Metal Ceilings 21R4003 5.20.21.pdf PDF
B.08 Memorandum Amendment Four 21R4003 5.13.21.pdf PDF
07 24 00 - Exterior Insulation and Finish Systems.pdf PDF
00 01 10 - TOC.pdf PDF
2021-04-19 - Structural Revised Sheets.pdf PDF
2021-04-19 - General and Architectural Revised Sheets.pdf PDF
00 01 15 - List of Drawings.pdf PDF
B.08 Amendment Four 21R4003 5.13.21.pdf PDF
07_84_00_-_Firestopping..pdf PDF
Rev 4 SB101 - FOUNDATION PLAN.pdf PDF
Revised Bid Schedule page 5 of 79.pdf PDF
2017.1058.02 - 21.04.23-VA COLUMBIA - GARAGE ADDITION - Revision 2 (002).pdf PDF
Parking Garage Project Device and Conduit Plan.pdf PDF
B.08 Final Amendment Three 21R4003 5.6.21.pdf PDF
B.08 Amendment Two 21R4003 4.29.21.pdf PDF
B.08 Amendment One 21R4003 4.21.21.pdf PDF
A.02 Amendment One Attachement Spec Revision 21R4003 4.21.21.pdf PDF
B.08 Site Visit Sign In Sheet 21R4003 4.21.21.pdf PDF
A.02 UFGS4288 21R4003 4.1.21.xlsx XLSX spreadsheet
A.02 17.1058.02 - RTA SPECIFICATIONS - VOL II 21R4003 4.1.21.pdf PDF
A.02 17.1058.02 - RTA SPECIFICATIONS - VOL I with Div1 Rev 021021 4.1.21.pdf PDF
A.02 UFGS4288 21R4003 4.1.21.txt TXT text file
B.08 VA Columbia Parking Expansion Solicitation 21R4003 4.1.21.pdf PDF
A.02 17.1058.02 - RTA CD DRAWINGS Revised 21R4003 4.1.21.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LENGTH OF SPACE EQUAL EQUAL LENGTH OF SPACE

EQ. EQUAL EQ.

XXX XXX

XXX

EQUAL EQUAL

VEHICULAR SIGN

CENTER OF DRIVE AISLE

STRIPING AND SIGNAGE GENERAL NOTES

SIGNAGE TO BE DESIGNED IN CONJUNCTION WITH THE VA DESIGN GUIDE

"PARKING LOTS AND PARKING STRUCTURES SIGNAGE" AND "MANUAL OF

UNIFORM TRAFFIC CONTROL DEVICES". SEE SIGNAGE SCHEDULE THIS

SHEET FOR ADDITIONAL INFORMATION.

GARAGE SIGNAGE SHALL BE COLOR CODED BY LEVEL. REFER TO COLORS

BELOW FOR SELECTIONS FROM DESIGN GUIDELINES. CONFIRM WITH

CONTRACTING OFFICER REPRESENTATIVE FOR FINAL COLOR SELECTION.

LEVEL 1 = MP10844 "GRAVITY TRACTOR" (RED)

LEVEL 2 = MP13427 "ANOLE GREEN" (GREEN)

LEVEL 3 = MP02160 "SAILBOAT BLUE" (BLUE)

LEVEL 4 = MP01220 "ANTARTICA ORANGE" (ORANGE)

PARKING SPACE STRIPING TO BE 4" WIDE YELLOW STRIPING. "TRAFFIC

YELLOW"

CROSS HATCH STRIPING TO BE 4" WIDE YELLOW STRIPING AT 24" O.C. TO BE

PLACED AT LOCATIONS AS SHOWN ON THE PLANS.

DIRECTIONAL ARROWS TO BE PAINTED YELLOW AT LOCATIONS AS SHOWN

ON THE PLANS.

PAINTED GRAPHICS TO BE PLACED AT LOCATIONS AS SHOWN ON THE

PLANS.

ALL SIGNS LOCATED AT ENTRY/EXIT SHOULD BE CENTERED IN LANES,

TYPICAL.

PARKING SPACE STRIPING DIMENSIONS INDICATED ARE NOMINAL

DIMENSIONS. TOLERANCES ARE AS FOLLOWS:

A. PARKING SPACE LENGTH = INDICATED LIGHT +/- 2".

B. PARKING SPACE WIDTH = INDICATED WIDTH +/- 1".

C. BASE LINE LENGTH = INDICATED LENGTH +/- 1"

D. STRIPE WIDTH = 4" +/- 1/4"

E. TOTAL DIM'S = INDICATED LENGTH +/- 2" PER RUN.

PARKING SPACE DIMENSIONS INDICATED ARE FROM THE FACE OF A WALL

OR COLUMN, UNLESS OTHERWISE INDICATED.

INSTALL SIGNS PLUMB AND LEVEL.

ALL JOINTS BETWEEN STRUCTURAL MEMBERS SHALL BE PROPERLY

PREPARED AND FILLED WITH JOINT SEALANT UNLESS OTHERWISE NOTED.

ALL JOINT EDGES, INCLUDING TOP AND BOTTOM OF HORIZONTAL

SURFACES AND BOTH FACES OF VERTICAL SURFACES, SHALL BE FORMED

OR TOOLED AS REQUIRED. JOINT SEALANT SHALL BE APPLIED ONLY TO TOP

OF HORIZONTAL SURFACES, AND SHALL BE APPLIED TO BOTH FACES OF

VERTICAL SURFACES UNLESS OTHERWISE NOTED.

CONTRACTOR SHALL HAVE WRITTEN APPROVAL FROM COR ON ALL

MARKING LAYOUTS BEFORE ANY APPLICATION.

CONTRACTOR SHALL PROVIDE CAR COUNTING SIGNAGE AT THE ENTRANCE

OF THE GARAGE. SEE EXAMPLE THIS SHEET OF A SIGN BY SIGNAL-TECH.

SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.

A

B

C

D

E

F

G

H

I

J

K

L

M

IN CASE OF FIRE,

USE STAIRS. DO NOT

USE ELEVATORS.

REFER TO VA SIGNAGE

GUIDELINE FOR ADDITION

INFORMATION

Room

XXXX

Name

ROOM NUMBER

REFER TO VA SIGNAGE DESIGN GUIDE

FOR ADDITIONAL INFORMATION

9"

6"

2'-0"

6" 1'-6"

2' -9

3"

L e v e l3'

-0

REFER TO VA SIGNAGE DESIGN GUIDE

FOR ADDITIONAL INFORMATION

SHADE INDICATES

COLOR CODING BY

LEVEL

'TEXT'

4L e v e l

Clearance 8'-4"

10'-0"

6"

REFER TO VA SIGNAGE DESIGN GUIDE FOR ADDITIONAL INFORMATION

'TEXT': BLACK BACKGROUND COLOR: YELLOW (OSHA)

Park

6'-0"

8" 4'-8" 8"

1' -0

3"

REFER TO VA SIGNAGE DESIGN GUIDE FOR ADDITIONAL INFORMATION

'TEXT'

SHADE INDICATES COLOR CODING BY LEVEL

Stairs

10'-0"

8" 8'-8" 8"

Exit1' -0

3"

REFER TO VA SIGNAGE DESIGN GUIDE FOR ADDITIONAL INFORMATION

SHADE INDICATES

COLOR CODING BY

LEVEL

WHITE REFLECTIVE TEXT, TYP

ALL VEHICULAR SIGNS

3'-6"

3 1/2" 2'-11" 3 1/2"

Stairs1' -0

REFER TO VA SIGNAGE DESIGN GUIDE FOR ADDITIONAL INFORMATION

SHADE INDICATES COLOR CODING BY LEVEL

REFER TO VA SIGNAGE

GUIDELINE FOR ADDITIONAL

INFORMATION

Reserved

Motorcycle Parking

1' - 0"

1'

BACKGROUND COLOR:

NEW VA BLUE

TEXT COLOR: WHITE

WALL MOUNTED

POST MOUNTED3"

3"

6'

0"

6'

0"

WALL POST

Exit

REFER TO VA SIGNAGE GUIDELINE FOR

ADDITION INFORMATION

1" 1/2"

'TEXT'

PAINTED

ALUMINUM

Watch for

3'-3"

1' -6

REFER TO VA SIGNAGE DESIGN GUIDE FOR ADDITIONAL INFORMATION

'TEXT' WHITE

BACKGROUND COLOR: YELLOW (OSHA)

Pedestrians

REFER TO VA SIGNAGE

GUIDELINE FOR ADDITIONAL

INFORMATION

P

1' - 0"

1'

BACKGROUND COLOR:

NEW VA BLUE

TEXT COLOR: WHITE

WALL MOUNTED

POST MOUNTED3"

3"

6'

0"

6'

0"

No Parking

Anytime

WALL POST

VERIFY HEADER OF

ELEVATOR FRAME IS TO

MEET R.O. REQUIREMENTS

12" X 24" CERAMIC WALL

TILE (CT-1) AROUND

ELEVATOR TRIM

PROVIDE STAINLESS STEEL

SCHLUTER STRIP AT ALL

EXPOSED EDGES OF TILE

6' - 0"

8'

BASE BID: PROVIDE TILE OVER

FUTURE ELEVATOR OPENING W/

DETAILS TO MATCH ADJACENT

ELEVATOR OPENING AND EXISTING

LEVELS BELOW.

FOR ADD ALTERNATE D: TILE

INSTALLATION THIS LEVEL AND

EXISTING TILE ON LEVELS BELOW

SHALL BE REQUIRED TO

ACCOMMODATE THE ELEVATOR

OPENING TO MATCH OPENING 401.

THIS INCLUDES ALL DEMOLITION OF

EXISTING MATERIALS AND NEW

WORK REQUIRED. SEE ADD

ALTERNATE D .

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD

A/E:

STAMPCONSULTANT

321 4 5 6 7 8 9 10

Consultant:

C U s e rs

\t s a n d e rs

\D o c u m e n ts

\1 .1

.0

A

V

A C o lu m b ia v ts a n d e rs g u id o n d e s ig n .c o m

.r v t

/2

/2

:2 :0

P

M

AE601

SIGNAGE SCHEDULE, STRIPING &

DETAILSGUIDON DESIGN

1221 N. PENNSYLVANIA ST. SUITE 200

INDIANAPOLIS, IN 46202

317-800-6388

STACEY PAUL

MES GROUP

550 NORTH REO STREET STE. 203

TAMPA, FLORIDA 33609

813-289-4700

LEE HILL

CORRECT PARKING SITE

DEFICIENCIES

COLUMBIA, SC

544-330

03/26/2021 AO TS

CONSTRUCTION

DOCUMENTS

SCALE: 1 1/2" = 1'-0"AE601

12 SIGN LOCATION DETAIL

SCALE: 1" = 1'-0"AE601

6 IN-01.04, WALL MOUNTED

SCALE: 3" = 1'-0"AE601

9 IN-04.02, WALL MOUNTED

SCALE: 1" = 1'-0"AE601

11 PS-03.01, SMALL WALL MOUNTED SIGN

SCALE: 1" = 1'-0"AE601

2 PS-09, CLEARANCE HEIGHT BANG BAR

SCALE: 1" = 1'-0"AE601

7 PS-02.04, WALL/BEAM MOUNTED

SCALE: 1" = 1'-0"AE601

8 PS-02.03, WALL/BEAM MOUNTED

SCALE: 1" = 1'-0"AE601

5 PS-06, WALL MOUNTED

SIGNAGE SCHEDULE

TYPE MARK 'TEXT' VA SIGN TYPE MOUNTING

SIGN

ELEVATION

(ON AS601) COMMENTS

[Clearance 8'-4"] Clearance 8'-4" PS-09: Clearance Height Bang Bar HANGING CRASH BAR 2

[Elevator] Elevator PS-06: Overhead wall-mounted indentification sign WALL MOUNTED 5

[Enter] Enter PS-08 24" Dimensional Letters, Entrance sign WALL MOUNTED 1

[Entrance] Entrance PS-08: 10" Dimensional letters, Entrance/occupancy sign WALL MOUNTED 1

[Exit, Park] -1 ↑ Exit ← Park PS-02.03: 15" - Long beam-mounted vehicular directional sign WALL MOUNTED 8

[Exit, Park] -2 → Exit → Park PS-02.03: 15" - Long beam-mounted vehicular directional sign WALL MOUNTED 8

[Exit, Park] -3 ← Exit ← Park PS-02.03: 15" - Long beam-mounted vehicular directional sign WALL MOUNTED 8

[Exit, Park] -4 ↑Exit ↑Park PS-02.03: 15" - Long beam-mounted vehicular directional sign WALL MOUNTED 8

[Exit, Park] -5 →Exit →Park PS-02.03: 15" - Long beam-mounted vehicular directional sign WALL MOUNTED 8

[Exit, Park] -6 ←Exit ←Park PS-02.03: 15" - Long beam-mounted vehicular directional sign WALL MOUNTED 8

[Exit] Exit PS-08: 10" Dimensional letters, Entrance/occupancy sign WALL MOUNTED 1

[Exit]-1 Exit PS-08 24" Dimensional Letters, Exit sign WALL MOUNTED 1

[In case of Fire] IN CASE OF FIRE, USE STAIRS. DO NOT USE ELEVATORS. IN-01.04: Wall mounted WALL MOUNTED 6

[Level, Elevator] Level 'X' ← Elevator PS-03.01: Small pedestrian and vehicle oriented sign WALL MOUNTED 11

[Level, Elevator] -2 Level 'X' → Elevator PS-03.01: Small pedestrian and vehicle oriented sign WALL MOUNTED 11

[Level] Level 'X' PS-03.01: Small pedestrian and vehicle oriented sign WALL MOUNTED 11

[Motorcycle Parking] -1 Reserved Motorcycle Parking PS-12.03: Parking Stall Designation WALL MOUNTED; POST MOUNTED WHERE NOT WALL MOUNT NOT POSSIBLE 3

[Motorcycle Parking] -2 Reserved Motorcycle Parking PS-12.03: Parking Stall Designation WALL MOUNTED; POST MOUNTED WHERE NOT WALL MOUNT NOT POSSIBLE 3

[No Parking Anytime] No Parking Anytime PS-12.03: Parking Stall Designation WALL MOUNTED; POST MOUNTED WHERE NOT WALL MOUNT NOT POSSIBLE 4

[Park] -1 ↑ Park PS-02.04: 15" - Short beam-mounted vehicular directional sign WALL MOUNTED 7

[Park] -2 → Park PS-02.04: 15" - Short beam-mounted vehicular directional sign WALL MOUNTED 7

[Room] Room 'X' IN-04.02: Secondary Room Identification (Small) WALL MOUNTED 9

[Stairs, Exit] -1 → Stairs ↑ Exit PS-02.03: 15" - Long beam-mounted vehicular directional sign WALL MOUNTED 8

[Stairs, Park] -1 → Stairs ↑ Park PS-02.03: 15" - Long beam-mounted vehicular directional sign WALL MOUNTED 8

[Stairs] Stairs PS-06: Overhead wall-mounted indentification sign WALL MOUNTED 5

[Stairs] -1 ← Stairs PS-02.04: 15" - Short beam-mounted vehicular directional sign WALL MOUNTED 7

[STOP] STOP Typical Street Traffic Stop Sign POST MOUNTED --

[Watch for Pedestrians] Watch for Pedestrians PS-04: Wall mounted warning sign WALL MOUNTED 10

SCALE: 1" = 1'-0"AE601

3 PS-12.03, WALL OR POST MOUNTED

SCALE: 1" = 1'-0"AE601

1 PS-08, ENTRY/EXIT WALL MOUNTED

SCALE: 1" = 1'-0"AE601

10 PS-04, WALL MOUNTED

SCALE: 1" = 1'-0"AE601

4 PS-12.03, WALL OR POST MOUNTED

SCALE: 12" = 1'-0"AE601

13 EXAMPLE CAR COUNT SIGN

Revisions: Date:

REVISION 3 - CERAMIC TILE 2021/04/27

SCALE: 1/4" = 1'-0"AE601

14 ELEVATOR INTERIOR ELEVATION

Sheets
AE601 - SIGNAGE SCHEDULE, STRIPING & DETAILS

File details come from the government source that posted it. Updated .