W912HN-21-B-3002_VOL1D_AMD4 Rev 2.pdf
PDF 3 MB Posted
- Solicitation number
- W912HN21B3002
About this file
This is a solicitation for a University Registrar, Force Modernization & Proponency Facility project. The solicitation was posted on 2 December 2020 seeking bids for construction services with bid opening on 12 January 2021 at 2:00 PM ET and bids due by 1:00 PM ET the same day. The solicitation includes four specification files, 21 drawing files, and WebEx information for the pre-bid conference. The work involves construction at Fort Gordon, Georgia for the U.S. Army Corps of Engineers Savannah District. Bids are due on 12 January 2021.
View the file
Other files
Show 40 more
Latest 50 of 62 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T Y
P
/2
101101 100 100155 SINK
3/4" 1' - 6" 3' - 6" 1' - 6" 1' - 6" 2' - 2" 2' - 2" 3/4"
/2
TYP
1' - 9 1/2"
PLAM-3
WD-2
EQF-2
EQF-3
FILLER
PANEL, TYP.
PT-1
B6
AI543A
TYP
A8
AI543
TYP
D6
AI543A
TYP
WATER
DISPENSER,
GFGI.
D8
AI543A
TYP
RE: ELEC
8 1/2" TYP.
F8
AI543
TYP
B8
AI543A
TYP
155 SINK 100100
2 1/4"2' - 6"3' - 6"2' - 6"2 1/4"
T Y
P
/2
/2
10' - 9"
TYP
1' - 9 1/2"
PLAM-3
WD-2
EQF-2
EQF-3
FILLER
PANEL, TYP.
PT-1
WATER
DISPENSER,
GFGI.
A5
AI543
TYP
C8
AI543
TYP
C5
AI543
TYP
RE: ELEC
8 1/2" TYP.
B1
AI543A
B3
AI543A
211 211101 101
1' - 6" 1' - 6" 2' - 2" 2' - 2" 2' - 2"
PLAM-3
EQF-2
MITERED
CORNER
C1
AI452
TYP
2' - 2" 2' - 2"
HOLD
2' - 10" 2' - 6" 2' - 6"
WARMING
OVEN,
GFCI.
211 212 212
PLAM-3
EQF-2
MITERED
CORNER
D1
AI452
TYP
155 SINK 101101100
T Y
P
/2
/2
PLAM-3
WD-2
EQF-2
EQF-3
FILLER
PANEL, TYP.
2' - 2" 3' - 6" 2' - 2" 1' - 6" 1' - 6" 3/4"
6 EQ WIDTH PANELS
11' - 0 1/2" V.I.F.
PT-1
WATER
DISPENSER,
GFGI.
RE: ELEC
8 1/2" TYP.
/2
WD-2
PT-1
F1
AI543
TYP
/2
T Y
P
/2
V.I.F.
1' - 2 1/2"
TYP
1' - 9 1/2"
WD-2
PT-1
D1
AI543A
D3
AI543A
F3
AI543
TYP
F1
AI543A
TYP
F6
AI543A
TYP
F8
AI543A
TYP
C3
AI543
TYP
/2
T Y
P
/2
TYP
1' - 9 1/2"
WD-2
PT-1
EQ4' - 0"4' - 0"EQ
WD-2
PT-3
OPEN TO
BEYOND
EQ 4' - 0" 4' - 0" EQ
WD-2
F5
AI543
TYP
B6
AI543A
TYP
B8
AI543A
TYP
C3
AI543
TYP
C5
AI543
TYP
C8
AI543
TYP
F1
AI543A
TYP
F3
AI543A
TYP
GENERAL ELEVATION NOTES
1. PROVIDE BLOCKING AT ALL TV LOCATIONS REFER TO TA
DRAWING SET FOR ADDITIONAL INFORMATION.
2. EQUIPMENT SHOWN FOR PLANNING PURPOSES. AV
COORDINATOR TO REVIEW MOUNTING HEIGHTS AND
PLACEMENT OF EQUIPMENT BEFORE INSTALLATION.
3. WALL MOUNTED RECEPTACLES ARE TO BE COORDINATED
WITH FINISHES AS INDICATED ON FINISH DRAWINGS. TO
BE INSTALLED FLUSH WITH FINISHED SURFACE.
4. ALL MONITORS TO BE MOUNTED CENTERED WITHIN THE
WALL U.N.O.
5. WHERE SECURITY DEVICES AND SIGNAGE ARE LOCATED
TOGETHER, ALIGN TO THE CENTERLINE OF SECURITY
DEVICE. U.N.O.
6. REFER TO IN-601 FOR FINISH LEGEND.
7. POWER OUTLET LOCATIONS ARE SHOWN ON ELEVATIONS
FOR REFERENCE PURPOSES, REFER TO EP- SERIES FOR
ADDITIONAL INFORMATION.
8. REFER TO AI541 FOR INTERIOR CASEWORK DETAILS.
9. COORDINATE WATER DISPENSER WATERLINES AND
GROMMETS WITH OWNER IN FIELD.
10. EQUIPMENT IS GFGI AND IS FOR REFERENCE ONLY.
11. REFER TO SHEET AI544 FOR WALL PANEL TYPES.
3' - 0"
5 1/2"
CASEWORK
AS SCHED.
EQF-3
EQF-2
KNEE WALL
REF. AI504
3' - 6"
1"EQUIPMENT OR
CASEWORK
AS SCHED.
EQF-3
EQF-2
KNEE WALL
REF. AI504
TA15
TA7
3' - 6" 3' - 0"
REF.
2' - 1" 1' - 6"
222 155 SINK 101
EQF-3
1" FILLER PANEL
BOTH SIDES
TA1D
PT-1
EQF-2
PLAM-2
US Army Corps of Engineers ®
G
2 3 4 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
C A
T E
G O
R Y
C O
D E
C:\rvt\2019\10053876-A-MCA2-Central_ECOOPER.rvt
1/15/2021 11:37:49 AM READY TO ADVERTISE (RTA)
AI452
MCA2
A R
C H
IT
E
C T
U R
A L
E N
L A
R G
E D
I N
T E
R
IO
R E
L E
V A
T
IO
N S
F O
R T
G O
R D
O N
G
E O
R G
IA
S A
V A
N N
A H
D
IS
T R
IC
T
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
S A
V A
N N
A H
G
A
H D
R A
R L
IN
G T
O N
V
IR
G
IN
IA
E C
O O
P E
R
H H
E
IL
E
D H
O F
M A
N N
H E
Z Z
E D
D
IN
E
N O
V E
M B
E R
W H
N B
-- 1 -3
-0
S C
I M
IS
S
IO
N
C O
M M
A N
D U
N
IV
E R
S
IT
Y R
E G
IS
T
R A
R F
O R
C E
M O
D E
R N
IZ
A
T
IO
N A
N D
P R
O P
O N
E N
C Y
F Y
P
N
1/4" = 1'-0" E7
CONNECTOR BAR STAFF BREAK
WEST ELEVATION - TYPICAL
1/4" = 1'-0" C5
STUDENT BREAK
SOUTH ELEVATION - TYPICAL
1/4" = 1'-0"
C2
STUDENT BREAK
ISLAND NORTH ELEVATION - TYPICAL
1/4" = 1'-0" D2
STAFF BREAK 408
ISLAND EAST ELEVATION
1/4" = 1'-0" A7
SOUTH BAR STAFF BREAK
WEST ELEVATION - TYPICAL
1/4" = 1'-0" E2
CONNECTOR BAR STAFF BREAK
SOUTH ELEVATION - TYPICAL
1/4" = 1'-0"
E5
CONNECTOR BAR STAFF BREAK
EAST ELEVATION - TYPICAL
1/4" = 1'-0" C7
STUDENT BREAK
EAST ELEVATION - TYPICAL
1/4" = 1'-0" A5
COMMAND GENERAL OFFICE
NORTH ELEVATION
1/4" = 1'-0"
A1
RECEPTION
EAST ELEVATION
1/4" = 1'-0" C1
STUDENT BREAK
ISLAND SECTION, TYP
1/4" = 1'-0" D1
STAFF BREAK 408
ISLAND SECTION - TYP.
1/4" = 1'-0" E1
LACTATION ROOM WEST ELEVATION
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/1
/2
1/19/21
CUT TOP COURSE
AS REQUIRED
05 50 13 - STEEL ANGLE
RETAINER CLIP EXPANSION
BOLTED TO FLOOR/ROOF
STRUCTURE
07 84 00
FIRE STOPPING
SECTION
STAGGERED AT 24" O.C.
ELEVATION
DESIGN BASIS: UL-HW-
D-0300
REFER TO UL LISTING
FOR COMPLETE
ASSEMBLY
REQUIREMENTS
04 20 00
CMU
/2
M
IN
STEEL BEAM W/
FIREPROOFING
/2
M
IN
M
A X
M
IN
O V
E R
L A
P
O N
B
L O
C K
O V
E R
L
P
N
B
O
C K
07 84 00
FIRE STOPPING
2" MIN OVERLAP
ONTO BEAM
FIREPROOFING
1" MIN
OVERLAP
ONTO
BLOCK
05 50 13 - STEEL ANGLE RETAINER
CLIP EXPANSION BOLTED TO
FLOOR/ROOF STRUCTURE
07 84 00
MINERAL WOOL
DESIGN BASIS: UL-HW-
D-0300
REFER TO UL LISTING
FOR COMPLETE
ASSEMBLY
REQUIREMENTS
GWB SOUND AND
SMOKE CLOSURE
STRIP, SECURED TO
STRUCTURE, PROVIDE
ON BOTH SIDES AT
SOUND WALLS
09 22 16 2"x33 MIL STRAPS
AT 16" O.C.
09 22 16
33 MIL Z-BARS TO
ACCOMMODATE
SFRM THICKNESS
07 81 00
FIREPROOFING
09 22 16
METAL STUDS
METAL DECK
(PERPENDICULAR TO
FLUTES)
METAL DECK
(PARALLEL TO FLUTES)
09 22 16
METAL
STUDS
STEEL BEAM
GWB CUT TO
FOLLOW PROFILE
OF DECKING;
REFER TO
GENERAL NOTE #15
FILL FLUTE VOID W/ SAB
EQ EQ
09 29 00
5/8" GWB
09 29 00
5/8" GWB
07 92 00
SEALANT BOTH SIDES
07 92 00 SEALANT
BOTH SIDES
09 22 16 2"x33 MIL
STRAPS AT 16"
O.C.
09 22 16
33 MIL Z-BARS TO
ACCOMMODATE
SFRM THICKNESS
07 81 00
FIREPROOFING
09 22 16
METAL STUDS
DESIGN BASIS: UL-HW-D-0043
METAL DECK
(PERPENDICULAR TO FLUTES)
DESIGN BASIS: UL-HW-D-0264
METAL DECK
(PARALLEL TO FLUTES)
09 22 16
METAL STUDS
DESIGN BASIS: UL-HW-D-0252
STEEL BEAM
/2
M
IN
/2
/2
/2
M
IN
09 29 00
5/8" GWB 1 OR 2 LAYERS,
REFER TO PARTITION TYPE
/2
M
IN
/2
09 29 00
5/8" GWB 1 OR 2 LAYERS,
REFER TO PARTITION TYPE
07 84 00
FIRESTOPPING
07 84 00
MINERAL
WOOL
07 84 00
FIRESTOPPING
07 84 00
MINERAL
WOOL
GENERAL NOTES - PARTITION
1. CONDITIONS INDICATED SHOW DESIGN INTENT, ESPECIALLY IN REGARD TO ACCOMMODATION OF STRUCTURAL DEFLECTION AND CONTINUITY OF INTEGRITY OF SOUND, SMOKE AND FIRE WALLS.
2. DESIGN INTENT DETAILS ARE NOT INTENDED TO BE PROPRIETARY. CONTRACTOR MAY EMPLOY SIMILAR HEAD-OF-WALL DESIGNS AND COMPONENTS AS APPROPRIATE
FOR CONDITIONS.
3. DESIGN INTENT DETAILS MAY NOT SHOW ALL CONDITIONS TO BE ENCOUNTERED ON A PROJECT. COMPLY WITH MANUFACTURER AND UL APPROVED METHODS FOR
ATYPICAL CONDITIONS.
4. SECURE TOP OF INTERIOR PARTITIONS TO SUPERSTRUCTURE IN A WAY THAT PROVIDES LATERAL STABILITY (PERPENDICULAR-TO AND IN-PLANE WITH WALL) YET
ALLOWING FOR A MINIMUM OF 3/4" OF VERTICAL DEFLECTION OF THE SUPERSTRUCTURE.
5. RIGIDLY SECURE SLOTTED TOP TRACK TO BUILDING SUPERSTRUCTURE IN AN APPROVED MANNER. EMPLOY Z-BARS, COLD-ROLLED CHANNELS OR SIMILAR SPACER TO
ACCOMMODATE THICKNESS OF SECTION 07 81 00 FIREPROOFING.
6. SLOTTED TOP TRACK, INDICATED ON THESE DETAILS, IS THE BASIS FOR DESIGN AND REFERS TO DEEP-LEG TRACKS WITH VERTICALLY SLOTTED HOLES. OPTIONAL MANUFACTURERS MAY PROVIDE SIMILAR, PROPRIETARY METHODS IN ACCORDANCE WITH THE PROVISIONS OF SPECIFICATION SECTION 09 22 16.
7. SECURE VERTICAL STUDS TO SLOTTED TOP TRACK AT MID-HEIGHT OF VERTICAL SLOTS IN TRACK. COMPONENTS INTENDED TO SLIDE VERTICALLY AS
SUPERSTRUCTURE DEFLECTS.
8. DO NOT SCREW GYPSUM WALLBOARD TO TOP TRACK OR SUPERSTRUCTURE. GWB SCREWS INTO THE STUDS MUST BE AT LEAST 1" BELOW THE BOTTOM OF THE TOP
TRACK.
9. REFER TO PARTITION STANDARDS FOR SPECIFIC WALL TYPES.
10. AT FIRE -RATED WALLS REFER TO SPECIFICATION SECTION 07 84 00 FOR ADDITIONAL REQUIREMENTS REGARDING HEAD-OF-WALL CONDITIONS.
11. MAINTAIN ACOUSTIC RATING WHERE SOUND-CONTROL WALLS ARE INDICATED.
12. FIRESTOPPING AND ACOUSTICAL SEALANTS SHALL AUTOBOND.
13. WHERE A WALL IS DESIGNATED AS BOTH A SOUND-CONTROL WALL AND A FIRE-RATED WALL, REFER TO FIRE-RATED HEAD-OF-WALL CONDITIONS.
14. WHERE A WALL IS DESIGNATED AS A SOUND-CONTROL WALL, FILL ALL VOIDS WITH SOUND ATTENTUATION BATTS (SAB).
15. SMOKE PARTITIONS REQUIRE THAT AT LEAST ONE LAYER OF GWB, AND SOUND-CONTROL WALLS REQUIRE AT LEAST ONE LAYER OF GWB ON EACH SIDE, BE CUT TO
FOLLOW UNDULATING SURFACES OF THE SUPERSTRUCTURE INCLUDING, BUT NOT LIMITED TO, FLUTES IN METAL DECKING AND JOISTS IN PAN JOIST SYSTEM. AT SOUND-CONTROL WALLS, PROVIDE 1/4" BETWEEN THE TOP OF GWB AND SUPERSTRUCTURE. AT BOTH SMOKE PARTITIONS AND SOUND-CONTROL WALLS, PROVIDE A CONTINUOUS BEAD OF SEALANT (AS SPECIFIED) TO SUPERSTRUCTURE. AT SOUND-CONTROL WALLS, ADDITIONAL LAYERS OF GWB MUST TERMINATE WITHIN 3" OF THE
SUPERSTRUCTURE.
SLOTTED DEEP LEG
DEFLECTION TRACK
SLIP CONNECTION
VERTICAL STUD
CUT TOP COURSE
AS REQUIRED
SECTION
STAGGERED AT 24" O.C.
ELEVATION
DESIGN BASIS: UL-HW-
D-1080
REFER TO UL LISTING
FOR COMPLETE
ASSEMBLY
REQUIREMENTS
04 20 00
CMU
/2
M
IN
05 50 13 - STEEL ANGLE RETAINER CLIP
EXPANSION BOLTED TO FLOOR/ROOF
STRUCTURE
07 84 00
FIRESTOPPING
07 84 00
MINERAL WOOL
05 50 13 - STEEL ANGLE
RETAINER CLIP EXPANSION
BOLTED TO FLOOR/ROOF
STRUCTURE
DESIGN BASIS: UL-HW-
D-1080
REFER TO UL LISTING
FOR COMPLETE
ASSEMBLY
REQUIREMENTS
US Army Corps of Engineers ®
G
2 3 4 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
C A
T E
G O
R Y
C O
D E
C:\rvt\2019\10053876-A-MCA2-Central_april.drake.rvt
1/18/2021 11:22:06 AM READY TO ADVERTISE (RTA)
AI502
MCA2
A R
C H
IT
E
C T
U R
A L
S T
A N
D A
R D
P A
R T
IT
IO
N D
E T
A
IL
S
F O
R T
G O
R D
O N
G
E O
R G
IA
S A
V A
N N
A H
D
IS
T R
IC
T
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
S A
V A
N N
A H
G
A
H D
R A
R L
IN
G T
O N
V
IR
G
IN
IA
A D
R A
K E
A D
R A
K E
D H
O F
M A
N N
H E
Z Z
E D
D
IN
E
N O
V E
M B
E R
W H
N B
-- 1 -3
-0
S C
I M
IS
S
IO
N
C O
M M
A N
D U
N
IV
E R
S
IT
Y R
E G
IS
T
R A
R F
O R
C E
M O
D E
R N
IZ
A
T
IO
N A
N D
P R
O P
O N
E N
C Y
F Y
P
N
NTS
A5
CMU AT METAL DECK AND STEEL STRUCTURE
NTS
F1
STUD PARTITIONS - SMOKE PARTITIONS AND SOUND CONTROL PARTITIONS
NTS
F5
STUD PARTITIONS - FIRE RATED PARTITIONS
NTS
C3
ISOMETRIC VIEW - SLOTTED TOP TRACK
NTS
C5
CMU AT METAL DECK
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/1
/2
DOOR SCHEDULE LEGEND
AL ALUMINUM
ANOD ANODIZED
GL-# GLAZING, RE: SPEC
HM HOLLOW METAL
STL STEEL
ST STAINED WOOD
PT PAINT
WD WOOD
DOOR SCHEDULE NOTES
1. SEE SPEC SECTION 08 41 13.
2. GLASS PANEL (GP-1) ADHERED TO
DOOR.
3. DOORS ARE A PART OF CURTAIN WALL
SYSTEM. MAINTAIN 32" CLEAR IN OPEN
POSITION.
US Army Corps of Engineers ®
G
2 3 4 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
C A
T E
G O
R Y
C O
D E
C:\rvt\2019\10053876-A-MCA2-Central_april.drake.rvt
1/18/2021 8:54:38 AM READY TO ADVERTISE (RTA)
A-601
MCA2
A R
C H
IT
E
C T
U R
D
O O
R S
C H
E D
U L E
F O
R T
G O
R D
O N
G
E O
R G
IA
S A
V A
N N
A H
D
IS
T R
IC
T
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
S A
V A
N N
A H
G
A
H D
R A
R L
IN
G T
O N
V
IR
G
IN
IA
A D
R A
K E
H H
E
IL
E
D H
O F
M A
N N
H E
Z Z
E D
D
IN
E
N O
V E
M B
E R
W H
N B
-- 1 -3
-0
S C
I M
IS
S
IO
N
C O
M M
A N
D U
N
IV
E R
S
IT
Y R
E G
IS
T
R A
R F
O R
C E
M O
D E
R N
IZ
A
T
IO
N A
N D
P R
O P
O N
E N
C Y
F Y
P
N
DOOR AND FRAME SCHEDULE - EXTERIOR
IDENTIFICATION DIMENSIONS PANEL FRAME
FIRE
RATING
STC
RATING
HARDWARE
SET NOTES
ROOM
NO. ROOM NAME DOOR NO.
WIDTH
HEIGHT
PANEL
COUNT TYPE MATL FINISH GLAZING TYPE MATL FINISH
FRAME DETAIL
W1 W2 TOTAL HEAD JAMB SILL
LEVEL 1
101 VESTIBULE X101A 2' - 10
1/2"
2' - 10
1/2"
5' - 9" 8' - 0" 2 FG AL PT GL-3 CW AL PT D9/ A517 C1/ A516 A1/ A516 CA14 3
101 VESTIBULE X101B 2' - 10
1/2"
2' - 10
1/2"
5' - 9" 8' - 0" 2 FG AL PT GL-3 CW AL PT D9/ A517 C1/ A516 A1/ A516 CA15 3
102 VESTIBULE X102A 2' - 10
1/2"
2' - 10
1/2"
5' - 9" 8' - 0" 2 FG AL PT GL-3 CW AL PT D9/ A517 C1/ A516 A1/ A516 CA14 3
102 VESTIBULE X102B 2' - 10
1/2"
2' - 10
1/2"
5' - 9" 8' - 0" 2 FG AL PT GL-3 CW AL PT D9/ A517 C1/ A516 A1/ A516 CA15 3
X103 4' - 0" 4' - 0" 8' - 0" 1 F HM PT - 1 HM PT D1/ A517 A1/ A517 A1/ A515 CA6
111 CORRIDOR X111 4' - 0" 4' - 0" 8' - 0" 1 FG AL PT GL-3 CW AL PT D6/ A517 A6/ A517 A1/ A516 CA6 OITC 25
147 CORRIDOR X147 4' - 0" 4' - 0" 8' - 0" 1 F HM PT - 1 HM PT D1/ A517 A1/ A517 A1/ A515 CA6 OITC 25
149 STAIR #1 X149 4' - 0" 4' - 0" 8' - 0" 1 FG AL PT GL-3 CW AL PT D6/ A517 A6/ A517 A1/ A516 CA6
160 LOADING DOCK X160A 3' - 0" 3' - 0" 7' - 10" 1 F HM PT - 1 HM PT E5/ A515 C5/ A515 A1/ A515 CA24
160 LOADING DOCK X160B 10' - 0" 10' - 0" 1 OC STL PT - STL PT E8/ A515 C8/ A515 CA27
163 BEF X163 2' - 10" 2' - 10" 5' - 8" 7' - 10" 2 F/F HM PT - 1 HM PT A5/ A515 C1/ A515 A1/ A515 CA23
164 MECH X164 2' - 10" 2' - 10" 5' - 8" 7' - 10" 2 F/F HM PT - 1 HM PT A5/ A515 C1/ A515 A1/ A515 CA25
165 ELEC X165A 2' - 10" 2' - 10" 5' - 8" 7' - 10" 2 F/F HM PT - 1 HM PT A5/ A515 C1/ A515 A1/ A515 CA25
165 ELEC X165B 3' - 0" 3' - 0" 6' - 0" 7' - 10" 2 F/F HM PT - 1 HM PT E5/ A515 C5/ A515 A1/ A515 CA25
166 FIRE PUMP X166 3' - 0" 3' - 0" 6' - 0" 7' - 10" 2 F/F HM PT - 1 HM PT E5/ A515 C5/ A515 A1/ A515 CA23
179 RESOURCE CENTER X179 4' - 0" 4' - 0" 8' - 0" 1 F HM PT - 1 HM PT D1/ A517 A1/ A517 A1/ A515 CA6 OITC 25
190 STAIR #5 X190 4' - 0" 4' - 0" 8' - 0" 1 F HM PT - 1 HM PT D1/ A517 A1/ A517 A1/ A515 CA6
ROOF
520 ELEV #2/3 MACH ROOM X520 3' - 0" 7' - 0" 1 F HM PT 1 HM PT F9/ A516 C9/ A516 A9/ A516 CA41
551 VESTIBULE X551 3' - 0" 7' - 0" 2 F HM PT 1 HM PT F9/ A516 C9/ A516 A9/ A516 CA2
570 ELEV #4/5 MACH ROOM X570 3' - 0" 7' - 0" 1 F HM PT 1 HM PT F9/ A516 C9/ A516 A9/ A516 CA41
DOOR AND FRAME SCHEDULE - LEVEL 1-2
IDENTIFICATION DIMENSIONS PANEL FRAME
FIRE
RATING
STC
RATING
HARDWARE
SET NOTES
ROOM
NO. ROOM NAME DOOR NO.
WIDTH
HEIGHT
PANEL
COUNT TYPE MATL FINISH GLAZING TYPE MATL FINISH HEAD JAMB SILLW1 W2 TOTAL
187 OFFICE 187 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 35 HW4
188 CONFERENCE 8-10 PN 188 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW4
103 STAIR #4 S103 4' - 0" 4' - 0" 8' - 0" 1 N HM PT GL-7 1 HM PT C9/ A603 A9/ A603 90 N/A CA42
114 STAIR #3 S114 4' - 0" 4' - 0" 8' - 0" 1 N HM PT GL-7 1 HM PT C9/ A603 A9/ A603 90 N/A HW19
149 STAIR #1 S149 4' - 0" 4' - 0" 8' - 0" 1 N HM PT GL-7 1 HM PT C9/ A603 A9/ A603 90 N/A HW19
157 STAIR #2 S157 3' - 0" 3' - 0" 6' - 0" 8' - 0" 2 N HM PT GL-7 1 HM PT C9/ A603 A9/ A603 90 N/A HW22
190 STAIR #5 S190 4' - 0" 4' - 0" 8' - 0" 1 N HM PT GL-7 1 HM PT C9/ A603 A9/ A603 90 N/A HW19
LEVEL 2
201 CORRIDOR 201 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 2 HM PT F4/ AI441E C4/ AI441E N/A CA36 1, 2
210 CORRIDOR 202 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 2 HM PT F4/ AI441E C4/ AI441E N/A CA36 1, 2
206A MALE TOILET 206A 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1 HM PT C9/ A603 A9/ A603 N/A HW9
206B FEMALE TOILET 206B 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1 HM PT C9/ A603 A9/ A603 N/A HW9
207 JAN. CLO 207 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1 HM PT C9/ A603 A9/ A603 N/A HW32
208 STAFF BREAK 208 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 30 HW8
212 CLASSROOM 212 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
213 CLASSROOM 213 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
216 STORAGE 216 4' - 0" 4' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A HW21
217 CLASSROOM 217 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
218 CLASSROOM 218 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
222A MALE TOILET 222A 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A HW9
222B FEMALE TOILET 222B 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A HW9
223 JAN. CLO. 223 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A HW10
224 STUDENT BREAK 224 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-4 1 HM PT C9/ A603 A9/ A603 N/A HW8
226 ELEC 226 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A HW7
227 TELECOM 227 3' - 6" 3' - 6" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A CA5
230 INSTRUCTOR 230A 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-4 1A HM PT C3/ A603 A3/ A603 N/A CA13
230 INSTRUCTOR 230B 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-4 1A HM PT C3/ A603 A3/ A603 N/A CA13
232 LAB 232B 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
233 LAB 233B 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
234 LAB 234B 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
236 LAB 236B 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
237 LAB 237B 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
238 LAB 238B 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
240 INSTRUCTOR 240 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-4 1 HM PT C9/ A603 A9/ A603 N/A CA13
243 LAB 243A 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
244 LAB 244 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
245 LAB 245 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
246 LAB 246A 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
248 STAFF BREAK 248 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 30 CA13
252 ELEC 252 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A HW7
253 TELECOM 253 3' - 6" 3' - 6" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A CA5
255 CAVE 255 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW4
256A FEMALE TOILET 256A 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1 HM PT C9/ A603 A9/ A603 N/A HW9
256B MALE TOILET 256B 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A HW9
263 CLASSROOM 263 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
264 CLASSROOM 264 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
265 CLASSROOM 265 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
266 CLASSROOM 266 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
272 STORAGE 272 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A HW21
273 CAVE 273 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1 HM PT C9/ A603 A9/ A603 35 HW4
276 CONFERENCE 20-30 PN 276 3' - 0" 3' - 0" 6' - 0" 8' - 0" 2 F HM PT 1 HM PT C9/ A603 A9/ A603 35 HW34
277 TELECOM 277 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A CA5
278 ELEC 278 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A HW7
280 OFFICE 280 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 35 HW4
281 OFFICE 281 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 35 HW4
282 OFFICE 282 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 35 HW4
283 OFFICE 283 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 35 HW4
284 OFFICE 284 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 35 HW4
285 OFFICE 285 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 35 HW4
286 CAVE 286 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW4
287 HELP DESK 287 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A HW8
288 STORAGE 288 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A HW10
291 CONFERENCE 8-10 PN 291 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1 HM PT C9/ A603 A9/ A603 35 HW4
292 OFFICE 292 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 35 HW4
293 OFFICE 293 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 35 HW4
294 OFFICE 294 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 35 HW4
295 DIRECTOR OFFICE 295 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 35 HW4
296 OFFICE 296 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 35 HW4
297 OFFICE 297 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 35 HW4
298 OFFICE 298 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 35 HW4
203 STAIR #4 S203 4' - 0" 4' - 0" 8' - 0" 1 N HM PT GL-7 1 HM PT C9/ A603 A9/ A603 90 N/A HW19
214 STAIR #3 S214 4' - 0" 4' - 0" 8' - 0" 1 N HM PT GL-7 1 HM PT C9/ A603 A9/ A603 90 N/A HW19
249 STAIR #1 S249 4' - 0" 4' - 0" 8' - 0" 1 N HM PT GL-7 1 HM PT C9/ A603 A9/ A603 90 N/A HW19
257 STAIR #2 S257 4' - 0" 4' - 0" 8' - 0" 1 N HM PT GL-7 1 HM PT C9/ A603 A9/ A603 90 N/A HW19
290 STAIR #5 S290 4' - 0" 4' - 0" 8' - 0" 1 N HM PT GL-7 1 HM PT C9/ A603 A9/ A603 90 N/A HW19
DOOR AND FRAME SCHEDULE - LEVEL 1-2
IDENTIFICATION DIMENSIONS PANEL FRAME
FIRE
RATING
STC
RATING
HARDWARE
SET NOTES
ROOM
NO. ROOM NAME DOOR NO.
WIDTH
HEIGHT
PANEL
COUNT TYPE MATL FINISH GLAZING TYPE MATL FINISH HEAD JAMB SILLW1 W2 TOTAL
LEVEL 1
101 VESTIBULE 100A 2' - 10 1/2" 2' - 10 1/2" 5' - 9" 8' - 0" 2 FG AL PT CW AL PT D6/A-517 C1/ A516 N/A HW16 3
101 VESTIBULE 100B 2' - 10 1/2" 2' - 10 1/2" 5' - 9" 8' - 0" 2 FG AL PT CW AL PT D6/A-517 C1/ A516 N/A HW16 3
102 VESTIBULE 100C 2' - 10 1/2" 2' - 10 1/2" 5' - 9" 8' - 0" 2 FG AL PT CW AL PT D6/A-517 C1/ A516 N/A HW16 3
102 VESTIBULE 100D 2' - 10 1/2" 2' - 10 1/2" 5' - 9" 8' - 0" 2 FG AL PT CW AL PT D6/A-517 C1/ A516 N/A HW16 3
105 PROCESSING 105 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1 HM PT C9/ A603 A9/ A603 N/A CA12
106A MALE TOILET 106A 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1 HM PT C9/ A603 A9/ A603 N/A HW9
106B FEMALE TOILET 106B 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1 HM PT C9/ A603 A9/ A603 N/A HW9
107 JAN. CLO 107 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1 HM PT C9/ A603 A9/ A603 N/A HW10
108 STAFF BREAK 108 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 30 HW8
110 CORRIDOR 111 3' - 6" 3' - 6" 7' - 0" 8' - 0" F HM PT 1 HM PT C9/ A603 A9/ A603 N/A CA11
112 CLASSROOM 112 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
113 CLASSROOM 113 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
115 CAVE 115 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW4
116 STORAGE 116 3' - 0" 3' - 0" 6' - 0" 8' - 0" 2 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A HW18
117 CLASSROOM 117 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
118 CLASSROOM 118 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
110 CORRIDOR 119 3' - 6" 3' - 6" 7' - 0" 8' - 0" F HM PT 1 HM PT C9/ A603 A9/ A603 N/A CA26
122A MALE TOILET 122A 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A HW9
122B FEMALE TOILET 122B 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A HW9
123 JAN. CLO. 123 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A HW10
124 STUDENT BREAK 124 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-4 1 HM PT C9/ A603 A9/ A603 N/A HW8
126 ELEC 126 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A HW7
127 TELECOM 127 3' - 6" 3' - 6" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A CA5
130 INSTRUCTOR 130A 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-4 1A HM PT C3/ A603 A3/ A603 N/A CA13
130 INSTRUCTOR 130B 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-4 1A HM PT C3/ A603 A3/ A603 N/A CA13
132 LAB 132B 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
133 LAB 133B 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
134 LAB 134 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
136 LAB 136 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
137 LAB 137B 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
138 LAB 138B 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
140 INSTRUCTOR 140 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT 1 HM PT C9/ A603 A9/ A603 N/A CA13
143 LAB 143 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
144 LAB 144 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
145 LAB 145 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
146 LAB 146 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW8
148 STAFF BREAK 148 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 30 CA13
152 ELEC 152 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A HW7
153 TELECOM 153 3' - 6" 3' - 6" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A CA5
154 STORAGE 154 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A HW21
155 CAVE 155 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW4
156A MALE TOILET 156A 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A HW9
156B FEMALE TOILET 156B 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1 HM PT C9/ A603 A9/ A603 N/A HW9
161 STORAGE 160A 3' - 0" 3' - 0" 6' - 0" 8' - 0" 2 F HM PT 1 HM PT C9/ A603 A9/ A603 N/A CA29
160 LOADING DOCK 160B 3' - 0" 3' - 0" 6' - 0" 8' - 0" 2 F HM PT 1 HM PT C9/ A603 A9/ A603 N/A CA29
161 STORAGE 161 3' - 0" 3' - 0" 6' - 0" 8' - 0" 2 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A HW18
163A TER 163A 3' - 6" 3' - 6" 8' - 0" 1 F HM PT 1 HM PT C9/ A603 A9/ A603 N/A CA5
165 ELEC 165A 3' - 6" 3' - 6" 8' - 0" 1 F HM PT 1 HM PT C9/ A603 A9/ A603 90 N/A HW44
171 CORRIDOR 171 4' - 0" 4' - 0" 8' - 0" 8' - 0" 2 F HM PT 1 HM PT C9/ A603 A9/ A603 N/A CA11
172 WORK RM 172A 4' - 0" 4' - 0" 8' - 0" 1 F HM PT 1 HM PT C9/ A603 A9/ A603 N/A CA13
172 WORK RM 172B 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A CA13
177 TELECOM 177 3' - 6" 3' - 6" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A CA5
178 ELEC 178 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 N/A HW7
179 RESOURCE CENTER 179 4' - 0" 4' - 0" 8' - 0" 8' - 0" 2 F HM PT 1 HM PT C9/ A603 A9/ A603 N/A CA17
180 OFFICE 180 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 35 HW4
181 OFFICE 181 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 35 HW4
182 OFFICE 182 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 35 HW4
184 CAVE 184 3' - 0" 3' - 0" 8' - 0" 1 F HM PT 1A HM PT C3/ A603 A3/ A603 35 HW4
185 OFFICE 185 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 35 HW4
186 OFFICE 186 3' - 0" 3' - 0" 8' - 0" 1 NG HM PT GL-5 1 HM PT C9/ A603 A9/ A603 35 HW4
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/1
/2
/2
2/
/2
2/
/2
2/
C O
R R
EC
TE
D F
IN
AL
S U
BM
IS
SI
O
N
O C
T
CORRECTED FINAL SUBMITTAL - NOT FOR CONSTRUCTION
/2
2/
/2
2/
C O
R R
EC
TE
D F
IN
AL
S U
BM
IS
SI
O
N
N O
VE
M
BE
R
W
2H N
B3
1-
-0
S
AV
A N
N A
H D
IS
TR
IC
T
W E
S T
O G
LE
TH
O R
P E
A V
E N
U E
S
AV
A N
N A
H , G
A
READY TO ADVERTISE (RTA)
A5 SIGN TYPE: IPS (INFO PLAQUE SMALL)
FRONT VIEW SIDE VIEW
SCALE: 1:4
NOTE: MOUNT WITH VHB TAPE AND SILICONE ADHESIVE AS REQUIRED.
EXTERIOR & INTERIOR APPLICATIONS. FOR EXTERIOR APPICATIONS,
USE EXTERIOR GRADE PAINT, PHOTOPOLYMER, ACRYLIC AND ADHESIVES.
MAXIMUM
OCCUPANCY:
MAXIMUM OCCUPANCY:
M6
M2 P1
M1 P2
F1
M1 P2
M2 P2
M2 P1 F1
PAINT RETURNS
1/4" 1/8"
3 /4
5 /8
3 /8
1 /3
1 /4
6 3/4"
6 3 /4"
FRONT VIEW SIDE VIEW
NOTE: MOUNT WITH VHB TAPE AND SILICONE ADHESIVE AS REQUIRED.
STAIR 2
STAIR 2
A8 SIGN TYPE: SIDR (STAIR ID - NO RE-ENTRY)
SCALE: 1:4
M6
M2 P1
M1 P2
F1
M2 P1 F2
M2 P1
M1 P2
ME1
M2 P1
F1
F2
M2 P1 F2
P1
PAINT RETURNS
1/4"1/8"
5 /8
5 /8
3 /8
1 /4
1 /2
5 /8
3 /8
1 /4
1 5 /8"
3 3 /4"
5/8"
NO RE-ENTRY
NO RE-ENTRY
7"
1'- 0"
AREA OF
REFUGE
PUSH FOR
HELP
AAREA OF REFUGE
PUSH FOR HELP
In the event of an emgergency, push large help button for evacuation assistance.
Wait here for assistance. Calls may take several minutes.
FRONT VIEW
FRONT VIEW
SIDE VIEW
SCALE : 1 : 2C5 SIGN TYPE : ARAD (AREA OF RESCUE ASSISTANCE DIRECTIONAL)
SCALE : 1 : 2E5 SIGN TYPE : ARAI (AREA OF RESCUE ASSISTANCE)
* NOTE: ARROW CHANGES DIRECTION PER SIGN LOCATION. REFER TO MESSAGE SCHEDULE FOR ARROW
DIRECTION BY LOCATION;
MOUNT WITH VHB TAPE AND SILICONE ADHESIVE AS REQUIRED.
AREA OF
REFUGE
1/8"1/8"
SIDE VIEW
1/8" 1/8"
NOTE:
1. ORIGINAL ADOBE ILLUSTRATOR ARTWORK WILL BE PROVIDED TO MANUFACTURERS.
2. DO NOT SCALE DRAWINGS.
3. MESSAGE TEXT FOR ALL SIGN TYPES SHALL BE COORDINATED WITH THE CLIENT PRIOR TO FABRICATION.
4. MESSAGE SCHEDULE, LOCATION PLANS, AND DRAWING SHEETS TO BE COORDINATED FOR COMPLETE INFORMATION.
5. INITIAL INSERTS TO BE PROVIDED BY THE MANUFACTURER.
M1 S8
P5
F1
M1 S8
M2 F1 P5
P5
M2 P5 F1
P5 F1
P5
CL
CL
NOTE: MOUNT WITH VHB TAPE AND SILICONE ADHESIVE AS REQUIRED.
M1 S8
M2 P5 F1
M1 S8
M2 P5 F1
M6
M6
R E
V
IS
E D
IN
A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/1
9/
5 /8
3 /8
5 /8
3 /8
1 /4
7 /8
3 /8
3 /8
EQ EQ
1'-1 3/4"
3/4"
3 /8 " 1 /4 "3 /8
" 5 /8
4 1 /8"
1" 7 /8
7 /8
3 /8
1"
1" 1 /2
1 /4
6 1/2"
5 1 /2"
5 /8
1 /2
5 /8
2" 5 /8
5 /8
1 /2
US Army Corps of Engineers ®
G
2 3 4 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
C A
T E
G O
R Y
C O
D E
C:\rvt\2019\10053876-A-MCA2-Central_ECOOPER.rvt
1/15/2021 11:30:53 AM READY TO ADVERTISE (RTA)
IN601
MCA2
IN
T
E R
IO
R
D E
S
IG
N
N O
T E
S A
N D
F
IN
IS
H
L E
G E
N D
F O
R T
G O
R D
O N
G
E O
R G
IA
S A
V A
N N
A H
D
IS
T R
IC
T
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
S A
V A
N N
A H
G
A
H D
R A
R L
IN
G T
O N
V
IR
G
IN
IA
E C
O O
P E
R
C N
O R
T H
C U
T T
D H
O F
M A
N N
H E
Z Z
E D
D
IN
E
N O
V E
M B
E R
W H
N B
-- 1 -3
-0
S C
I M
IS
S
IO
N
C O
M M
A N
D U
N
IV
E R
S
IT
Y R
E G
IS
T
R A
R F
O R
C E
M O
D E
R N
IZ
A
T
IO
N A
N D
P R
O P
O N
E N
C Y
F Y
P
N
SS SOLID SURFACE SS-1 KRION K LIFE SNOW SERIES SNOW WHITE EAST 1100 G0 VARIES
SH ROLLER SHADES 12 24 13 SH-1 MECHOSHADE SOHO COLLECTION 1100 SERIES NICKEL VARIES 5X SYSTEM, SHADE TO BE 5% OPEN FACTOR
PLAM-3 INTERIOR ARTS 1040 NAT WHITE NEEDLE NATURAL
PLAM-2 NOT USED
PLAM PLASTIC LAMINATE 06 41 16.00 10 PLAM-1 WILSONART TRACELESS SNOW WHITE VELVET 15501-31
EQF-3 WILSONART QUARTZ MARBLE FALLS Q4033 2 CM BACKSPLASH
EQF-2 WILSONART QUARTZ MARBLE FALLS Q4033 3 CM COUNTERTOP
EQF ENGINEERED QUARTZ 06 61 90 EQF-1 NOT USED
DF DECORATIVE FILM 08 87 33 DF-1 3M FASARA AERINA DOT 112918-5 WHITE VARIES CUSTOM GRADIENT
CG CORNER GUARD 10 26 00 CG-1 C-S GROUP HEAVY DUTY CORNER GUARDS STAINLESS STEEL
MISCELLANEOUS
10 26 00 WP-11 C-S GROUP ACROVYN WALL PROTECTION 949 WHITE 6' HIGH
WP-H FUNDERMAX MAX COMPACT INTERIOR ARCTIC WHITE 4100 MM X 1300 MM x 12 MM CUSTOM PATTERN
WP-G FUNDERMAX MAX COMPACT INTERIOR ARCTIC WHITE 4100 MM X 1300 MM x 12 MM CUSTOM PATTERN
WP-F FUNDERMAX MAX COMPACT INTERIOR ARCTIC WHITE 4100 MM X 1300 MM x 12 MM CUSTOM PATTERN
WP-E FUNDERMAX MAX COMPACT INTERIOR ARCTIC WHITE 4100 MM X 1300 MM x 12 MM CUSTOM PATTERN
WP-D FUNDERMAX MAX COMPACT INTERIOR ARCTIC WHITE 4100 MM X 1300 MM x 12 MM CUSTOM PATTERN
WP-C FUNDERMAX MAX COMPACT INTERIOR ARCTIC WHITE 4100 MM X 1300 MM x 12 MM CUSTOM PATTERN
WP-B FUNDERMAX MAX COMPACT INTERIOR ARCTIC WHITE 4100 MM X 1300 MM x 12 MM CUSTOM PATTERN
WP WALL PANEL 06 20 00 WP-A FUNDERMAX MAX COMPACT INTERIOR ARCTIC WHITE 4100 MM X 1300 MM x 12 MM FLAT PANEL
WD-2 PARKLEX DRY INTERNAL PHENOLIC AMERICAN OAK 2440 MM x 1220 MM x 11MM TRIM PIECES THICKNESS VARY
WD WOOD COMPOSITE PANELS 06 20 00 WD-1 ACGI GB1-7400-C SOLID WHITE ASH PLANE CUT
WC-2 DESIGNTEX WALLCOVERINGS WANNABE 6646-406 NAVY 3 MM, 8' HIGH DIRECT GLUE
WC WALL COVERING 09 72 00 WC-1 NOT USED
PT-11 SHERWIN WILLIAMS LOW VOC WATERBORNE ACRYLIC DRYFALL MATCH PT-4 DRYFALL
PT-10 SHERWIN WILLIAMS MATTE MATCH PT-7
PT-9 SHERWIN WILLIAMS ENVIROLASTIC 940 DTM MATCH PT-7 SHOP APPLIED METAL COATING, STRINGERS AND HANDRAILS
PT-8 NOT USED
PT-7 SHERWIN WILLIAMS EGGSHELL SW 6990 CAVIAR 251-C2 BLACKOUT
PT-6 MDC FUZE CLEAR DRY ERASE
PT-5 SHERWIN WILLIAMS LOW VOC WATERBORNE ACRYLIC DRYFALL MATCH PT-1 DRYFALL
PT-4 SHERWIN WILLIAMS NETWORK GREY SW 7073
PT-3 BENJAMIN MOORE AURORA 2135-20 STONECUTTER
PT-2 WOLF GORDON SCUFFMASTER MATCH PT-1 HEAVY DUTY PAINT
PT PAINT 09 90 00 PT-1 BENJAMIN MOORE AURORA CHANTILLY LACE 2121-70
GP GLASS WALL PANEL 08 81 00 GP-1 MCGROGY LAMINATED GLASS WHITE VARIES CAPTIVEHOOK MOUNTING SYSTEM
FMP FORMED METAL PANEL 05 72 00 FMP-1 METAL FABRICATION FORMED ALUMINUM POWDER COAT TO MATCH CENTRIA 9918 DOVE... VARIES
CWT PORCELAIN WALL TILE 09 30 10 CWT-1 DALTILE SLIM LITE TERRA STONE TP54 39" X 118" (1/8")
AWP-4 NOVAWALL EcoTRAC WELTLESS EDGE LUNA LUMINESCENTE LLM-668 STELLA 1" THICK
AWP-3 NOVAWALL EcoTRAC WELTLESS EDGE MAHARAM: TEK-WALL ASPECT 300023/016 CODEX 1" THICK
AWP-2 NOVAWALL EcoTRAC WELTLESS EDGE MAHARAM: GLANCE 901891/001 SHARKFIN 1" THICK TACKABLE
AWP ACOUSTIC WALL PANEL 09 84 20 AWP-1 NOVAWALL EcoTRAC WELTLESS EDGE MAHARAM EMIT 466378/003 CHIFFON 1" THICK TACKABLE
WALL
PBT TILE BASE 09 30 10 PBT-1 DALTILE PORTFOLIO IRON GREY P-43C9 3" X 12" BULLNOSE
MB ALUMINUM METAL BASE 05 72 00 MB-1 SAF METAL FABRICATION AAMA 2605 POWDER COATING ALUMINUM... WHITE 4" H MAIN LOBBY
RB-5 ROPPE SIMPLICITY #400 170 WHITE 4" H
RB-4 ROPPE PINNACLE- STRAIGHT BASE 123 CHARCOAL 3" H PANELS AT CARPET
RB-3 ROPPE PINNACLE- COVE BASE 123 CHARCOAL 3" H CORRIDORS
RB-2 ROPPE PINNACLE- COVE BASE 123 CHARCOAL 4" H HARD SURFACES
RB RUBBER BASE 09 65 00 RB-1 ROPPE PINNACLE- STRAIGHT BASE 123 CHARCOAL 4" H CARPET
BASE
TER RESINOUS MATRIX TERRAZZO FLOORING 09 66 23 TER-1 TERRAZZO & MARBLE... THIN SET EPOXY TM # 20-705 1/2"
RAF/SDT-1 RESILIENT STATIC DISSIPATIVE TILE ON RAISED ACCESS... 09 62 38 RAF/SDT-1 STATICWORX ECLIPSE EC 6103 PRESTO 24" X 24" (2 mm)
RAF/RT RESILIENT TILE ON RAISED ACCESS FLOORING 09 65 00 RAF/RT-1 JOHNSONITE MINERALITY MRLR-PA8 - META 12" X 24" (0.125") SURFACE TEXTURE: LEATHER
PFT-1 PORCELAIN FLOOR TILE 09 30 10 PFT-1 DALTILE PORTFOLIO IRON GREY PF06 12" X 24"
CS CONCRETE SEALER 03 33 00 CS-1 MASTERKURE CC 200 WB CLEAR
CPT-2 PATCRAFT ENTRY POINT MODULAR STERLING/00500 24" X 24" (8.84 mm) 1/4 TURN INSTALLATION
CPT CARPET TILE 09 68 00 CPT-1 PATCRAFT METALLIC ALCHEMY/ IO422 NICKEL GRAPHITE/00530 12" X 48" ASHLAR INSTALLATION
RAF/CPT CARPET TILE ON RAISED ACCESS FLOORING 09 68 00 RAF/CPT-1 PATCRAFT METALLIC ALCHEMY/ IO422 NICKEL GRAPHITE/00530 12" X 48" (5 mm) ASHLAR INSTALLATION
FLOOR
FCB FELT CEILING BAFFLES 09 51 00 FCB-1 FILZ FELT AKUSTICA 25 BAFFLE 150 WEISS 6' X 12" COVERED EDGE
ACT-7 ROCKFON SONAR CDX 14602 WHITE 2'x 5' CONCEALED-X GRID, TRIM 252427:INFS:STD:2:AL
ACT-6 ROCKFON SONAR CDX 14601 WHITE 2'x 4' CONCEALED-X GRID, TRIM 252427:INFS:STD:2:AL
ACT-5 ROCKFON SONAR SLN 16203 WHITE 2'x 6' SQUARE TEGULAR NARROW, TRIM 252427:INFS:STD:2:AL
ACT-4 ROCKFON SONAR CDX 14601 WHITE 2 X 4 CONCEALED X-GRID, BRICK, TRIM 252427:INFS:STD:2:AL
ACT-3 ROCKFON SONAR CDX 14603 WHITE 2'x 6' CONCEALED-X GRID, TRIM 252427:INFS:STD:2:AL
ACT-2 ROCKFON SONAR SLN 16200 WHITE 2'x 2' SQUARE TEGULAR NARROW, TRIM 252427:INFS:STD:2:AL
ACT ACOUSTIC CEILING TILE 09 51 00 ACT-1 ROCKFON SONAR CDX 16604 WHITE 2'x 8' CONCEALED-X GRID, TRIM 252427:INFS:STD:2:AL
CEILING
KEY ITEM SPEC SECTION KEY MANUFACTURER PRODUCT SERIES/NO. COLOR SIZE NOTES
FINISH LEGEND
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/1
/2
| AI452 ARCHITECTURAL - ENLARGED INTERIOR ELEVATIONS |
| AI502 ARCHITECTURAL - STANDARD PARTITION DETAILS |
| A-601 ARCHITECTURAL - DOOR SCHEDULE |
| AG505 WAYFINDING - SIGN DETAILS - SIGN TYPES ARA, ARAD, IPS, SIDR |
| IN601 INTERIOR DESIGN - NOTES AND FINISH LEGEND |
File details come from the government source that posted it. Updated .