W912HN-21-B-3002_VOL1C_AMD3_Rev 1.pdf

PDF 15 MB Posted

Attached to
PN88725 MCA2 University Registrar, Force Modernization & Proponency Facility
Solicitation number
W912HN21B3002
Issued by

About this file

This document provides details of a federal contract solicitation. The solicitation number is W912HN21B3002 and is seeking proposals for construction services for the PN88725 MCA2 University Registrar, Force Modernization & Proponency Facility project. The solicitation was posted on December 2nd, 2020 and involves four specification files and nine drawing files. The bid opening date is January 12th, 2021 at 2:00 PM Eastern Time, with bids due at 1:00 PM Eastern Time on that same date. Interested parties can obtain additional information by attending a pre-bid WebEx meeting. The soliciting agency is the Department of the Army Corps of Engineers Engineering District Savannah. The response summarizes the key details regarding the products/services required, response dates, federal agency involved, and other relevant information as requested.

View the file

Other files

File Type Posted
C.04. W912HN21B3002 MCA2 Abstract-s.pdf PDF
W912HN21B3002 Bid Opening Sign In Roster.pdf PDF
W912HN21B30020007 Conformed Copy.pdf PDF
W912HN21B30020007 Amendment.pdf PDF
B.08. W912HN21B3002 0006 Conformed Copy.pdf PDF
B.08. W912HN21B3002 0006 AMD.pdf PDF
B.08. W912HN21B3002 0005 Conformed Copy.pdf PDF
B.08. W912HN21B3002 0005 AMD.pdf PDF
B.08. W912HN21B3002 0005 ProjNet Report.pdf PDF
W912HN-21-B-3002_VOL1B_AMD4_Rev 2.pdf PDF
W912HN-21-B-3002_VOL1F_AMD4 Rev 1.pdf PDF
21B3002vol2 Rev 2.PDF PDF
W912HN-21-B-3002_VOL1C_AMD4 Rev 2.pdf PDF
B.08. W912HN21B3002 0004 AMD.pdf PDF
W912HN-21-B-3002_VOL1L_AMD4 Rev 1.pdf PDF
21B3002vol3 Rev 1.PDF PDF
W912HN-21-B-3002_VOL1K_AMD4 Rev 1.pdf PDF
W912HN-21-B-3002_VOL1E_AMD4 Rev 1.pdf PDF
W912HN-21-B-3002_VOL1D_AMD4 Rev 2.pdf PDF
21B3002vol1 Rev 3.PDF PDF
W912HN-21-B-3002_VOL1H_AMD4 Rev 1.pdf PDF
W912HN-21-B-3002_VOL1J_AMD4 Rev 1.pdf PDF
W912HN-21-B-3002_VOL1D_AMD3_Rev1.pdf PDF
W912HN-21-B-3002_VOL1A_AMD3_Rev 1.pdf PDF
W912HN-21-B-3002_VOL1B_AMD3_Rev 1.pdf PDF
21B3002vol2_Rev 1.PDF PDF
21B3002vol1_Rev 2.PDF PDF
B.08. W912HN21B3002 0003 Amd.pdf PDF
B.08. W912HN21B3002 Site Visit pic 10 P4278456.JPG JPG image
B.08. W912HN21B3002 Site Visit pic 2 IMG_0614.jpg JPG image
B.08. W912HN21B3002 0002 Amendment.pdf PDF
B.08. W912HN21B3002 Site Visit pic 8 P4278411.JPG JPG image
B.08. W912HN21B3002 Site Visit pic 9 P4278455.JPG JPG image
B.08. W912HN21B3002 Site Visit pic 7 P4278410.JPG JPG image
B.08. W912HN21B3002 Site Visit pic 1 IMG_0613.jpg JPG image
B.08. W912HN21B3002 Site Visit pic 5 P4278408.JPG JPG image
B.08. W912HN21B3002 Site Visit pic 6 P4278409.JPG JPG image
B.08. W912HN21B3002 MCA Projects_Google Earth.pdf PDF
B.08. W912HN21B3002 Site Visit pic 4 P4278407.JPG JPG image
B.08. W912HN21B3002 Site Visit pic 3 IMG_0616.jpg JPG image
B.08. W912HN21B3002 0002 Conformed solicitation.pdf PDF
B.08. W912HN21B3002 Site Visit Notes.pdf PDF
B.08. W912HN21B3002 Site Visit Attendee List.pdf PDF
B.08. W912HN21B3002 Site Visit pic 11 P4278457.JPG JPG image
21B3002vol1 rev 1.PDF PDF
B.08. W912HN21B3002 Amd 0001.pdf PDF
21B3002vol4 rev 1.PDF PDF
W912HN-21-B-3002_VOL1G.pdf PDF
W912HN-21-B-3002_VOL1C.pdf PDF
21B3002vol1.PDF PDF
Show 40 more

Latest 50 of 62 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DN

A1

A-319

A5

A-319

D6

A-319

D4

A-319

D7

A-521

SIM

F1

A-319

H J K

FD

MATCHLINE - SEE:A-105D

M A

T C

H L

IN

E

S

E E

:A -1

F

GE

VESTIBULE

STAIR #2

ELEV #1

AI412

A8

X551

S557

METAL DOWNSPOUT AND

SPLASHBLOCK

METAL LADDER

65'-10 1/4" ROOF H.P.

AI431

D3

30' - 0" 30' - 0"

34' - 4" 31' - 0" 31' - 0"

METAL DOWNSPOUT AND

SPLASHBLOCK

EXPANSION JOINT

DAVIT BASE, TYP

TERRA COTTA COPING

ROOF DRAIN, PRIMARY

AND OVERFLOW, TYP

D6 2

D

S

S6 2

METAL DOWNSPOUT AND

SPLASHBLOCK

W A

L K

B O

A R

D S

WALKBOARDS

W A

L K

B O

A R

D S

S6 2

S

A

A

A

A3 0

A

UNDER STAIR

GUARD RAIL

2' - 0"

12' - 4"

15' - 3 3/4" 2' - 0"

2' - 0" 2' - 0"

VESTIBULE

CS-1

PT-1

EXP

REFER TO INTERIOR

FINISH PLANS FOR

FINISH NOTES AND KEY

ROOF PLAN LEGEND AND

GENERAL NOTES

TAPERED ROOF INSULATION

1. UNLESS NOTED OTHERWISE, STRUCTURAL

ROOF DECK SLOPED AT 1/2" / 1' MINIMUM.

REFER STRUCTURAL FOR SLOPE OF ROOF

DECKS.

2. UNLESS NOTED OTHERWISE, TAPERED

INSULATION TO SLOPE AT 1" / 1'.

3. CRICKET AND SADDLE ANGLES TO BE 14

DEGREES.

4. REFER TO A-521 FOR ROOF DETAILS.

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

C A

T E

G O

R Y

C O

D E

C:\rvt\2019\10053876-A-MCA2-Central_jamie.krissoff.rvt

1/6/2021 12:01:10 PM READY TO ADVERTISE (RTA)

A-105E

MCA2

A R

C H

IT

E

C T

U R

A L

R O

O F

P L A

N

A R

E A

E

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

A D

R A

K E

J K

R

IS

S O

F F

D H

O F

M A

N N

H E

Z Z

E D

D

IN

E

N O

V E

M B

E R

W H

N B

-- 1 -3

-0

S C

I M

IS

S

IO

N

C O

M M

A N

D U

N

IV

E R

S

IT

Y R

E G

IS

T

R A

R F

O R

C E

M O

D E

R N

IZ

A

T

IO

N A

N D

P R

O P

O N

E N

C Y

F Y

P

N

1/8" = 1'-0" A1

ROOF PLAN - AREA E

NORTH

KEY PLAN

A

C

D

EF

B

8'4' 16'0

SCALE: 1/8"=1'-0"

8. UNLESS NOTED OTHERWISE, PROVIDE SPRAY-APPLIED

FIREPROOFING AT ALL PRIMARY STRUCTURAL STEEL TO

ACHIEVE REQUIRED FIRE RATING. REFER TO LIFE SAFETY

DRAWINGS. REFER TO STRUCTURAL DRAWINGS FOR

PRIMARY STRUCTURAL ELEMENTS TO BE INTUMESCENT

COATED.

7. REFER TO LIFE SAFETY DRAWINGS FOR ADDITIONAL FIRE /

SMOKE RATING REQUIREMENTS.

6. ALL DOOR FRAMES ARE TO BE INSTALLED 4” AWAY FROM

ADJACENT PERPENDICULAR WALLS, UNLESS NOTED

OTHERWISE.

5. ALL INTERIOR FURRING AT NON-STC RATED COLUMNS ARE

TYPE “A3 0” UNLESS NOTED OTHERWISE. FOR STC RATED

COLUMNS, REFER TO A-110 SERIES - ACOUSTICAL

BOUNDARY PLANS.

4. ALL NON-LOAD BEARING INTERIOR WALLS ARE TYPE “U3 0”

UNLESS NOTED OTHERWISE.

3. UNLESS NOTED OTHERWISE, ALL DIMENSIONS ARE TO: -

COLUMN CENTERLINES: - FACE OF GWB: - FACE OF

MASONRY: - FACE OF CONCRETE.

2. DO NOT SCALE DRAWINGS. IF DIMENSIONAL INFORMATION

IS REQUIRED & NOT FOUND, NOTIFY CONTRACTING

OFFICER IMMEDIATELY FOR CLARIFICATION.

1. DRAWINGS & SPECIFICATIONS ARE COMPLEMENTARY

COMPONENTS OF THE CONTRACT DOCUMENTS. REVIEW

ALL DRAWINGS AND SPECIFICATIONS FOR THE COMPLETE

SCOPE OF WORK. NOTIFY CONTRACTING OFFICER

IMMEDIATELY FOR CLARIFICATION IF INCONSISTENCIES,

CONTRADICTIONS OR OMISSIONS ARE DISCOVERED.

FLOOR PLAN GENERAL NOTES

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/0

/2

1/8/21

TSRQ

M A

T C

H

LI

N E

S

E E

:A C

B

OPEN

OFFICE

STAIR #5

OFFICE

OFFICE

OFFICE

TYP

1' - 0"

8 1/2"

8"

/2

4"

ALIGN

A L

IG

N A

L

IG

N

ALIGN

END CEILING GRID

ON A FULL TILE.

/2

E Q

E Q

ACT-1

2' - 0"

ACT-4

V

IF

2' - 0"

VIF

V

IFACT-6

2' - 0"

ACT-6

REFLECTED CEILING PLAN LEGEND

LINEAR LIGHT FIXTURE

LINEAR PENDANT LIGHT FIXTURE

DOWN LIGHT FIXTURE

EXIT SIGN

SPEAKER

ACOUSTICAL CEILING TILE

SIZE VARIES REFER TO IN DRAWING SERIES

CEILING BAFFLES

SIZE VARIES REFER TO IN DRAWING SERIES

GYPSUM BOARD CEILING

EXPOSED

2 HOUR FIRE-RATED GYPSUM

BOARD SHAFT ENCLOSURE CEILING

FORMED METAL PANEL (FMP-1)

EXPANSION JOINT COVER (EJ-2)

TUBE LIGHT FIXTURE

ADD SUPPLEMENTAL BACKER ABOVE

CEILING. REFER TO SPECIFICATION 09 51 00.

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

C A

T E

G O

R Y

C O

D E

C:\rvt\2019\10053876-A-MCA2-Central_HHEILE.rvt

1/7/2021 10:10:24 AM READY TO ADVERTISE (RTA)

AC101A

MCA2

A R

C H

IT

E

C T

U R

A L

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

L E

V E

L

A

R E

A A

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

A D

R A

K E

J K

R

IS

S O

F F

D H

O F

M A

N N

H E

Z Z

E D

D

IN

E

N O

V E

M B

E R

W H

N B

-- 1 -3

-0

S C

I M

IS

S

IO

N

C O

M M

A N

D U

N

IV

E R

S

IT

Y R

E G

IS

T

R A

R F

O R

C E

M O

D E

R N

IZ

A

T

IO

N A

N D

P R

O P

O N

E N

C Y

F Y

P

N

NORTH

KEY PLAN

A

C

D

EF

B

8'4' 16'0

SCALE: 1/8"=1'-0"

1/8" = 1'-0" A1

RCP - LEVEL 1 - AREA A

15. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED AND GWB CEILINGS SHALL BE CENTERED AND

EQUALLY SPACED ON EXTENTS UNLESS NOTED

OTHERWISE.

14. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED CEILINGS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

13. FOR ALL ACT CEILINGS THAT MEET AN EXPOSED

STRUCTURAL COLUMN END CEILING 1" FROM THE FACE OF

FLANGES WITH PERIMETER TRIM REFER TO E7/AI521.

12 ALIGN BULKHEADS WITH COLUMN FURRINGS OR EDGES,

UNLESS OTHERWISE NOTED.

11 PROVIDE ROLLER SHADES AT ALL EXTERIOR GLAZING,

EXCEPT AT STAIRS AND GLAZING BETWEEN GRIDS 6 AND 7

ON LEVELS 1 AND 2.

10. FOR ALL SUSPENDED CEILING ELEMENTS THAT DO NOT

TERMINATE AT A WALL PAINT EXPOSED CEILING ABOVE A

MINIMUM OF 3’-0” FROM EACH FACE OF PERIMETER TRIM

WITH PT-5 UNLESS NOTED OTHERWISE.

9. ALL SUSPENDED ACT CEIILNG ELEMENTS THAT DO NOT

TERMINATE AT A WALL REFER TO E8/AI521 PERIMETER TRIM

DETAILS.

8. REFERENCE TYPICAL CEILING DETAILS FOR CEILING

PERIMETER AND CONTROL JOINT DETAILS.

7. REFER TO MILLWORK DRAWINGS AND ELECTRICAL PLANS

FOR INTEGRATED LIGHTING.

6. UNLESS NOTED OTHERWISE, ALL DIMENSIONS TO LIGHT

FIXTURES ARE TO: -FIXTURE CENTERLINES: - COLUMN

CENTERLINES: - FACE OF GWB: - FACE OF MASONRY: - FACE

OF CONCRETE.

5. CENTER CEILNG LIGHTS, SPRINKLER HEADS, AND OTHER

CEILING MOUNTED DEVICES (RECESSED OR SURFACE

MOUNTING) IN CEILING TILE EXTENTS UNLESS NOTED

OTHERWISE.

4. LAY-IN CEILING PANELS SHALL NOT BE SMALLER THAN 6"

WIDE, TYPICAL.

3. CENTER CEILING TILES IN ROOM OR CENTER CEILING GRID

TO THE CENTER OF ROOM, UNLESS NOTED OTHERWISE.

2. REFER TO FINISH PLANS FOR CEILING TYPES AND FINISHES.

1. ALL CEILNG HEIGHTS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

REFLECTED CEILING PLAN

GENERAL NOTES

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/0

/2

L

H K

M N P

STAFF

BREAK

STAIR #4

CONFERENCE

8-10 PN

J.4H.6

MATCHLINE - SEE:AC101C

M A

T C

H

LI

N E

S

E E

:A C

A

RESOURCE

CENTER

OFFICE

OFFICE

OFFICE

TELECOM

ELEC

WORK/COPY

PROCESSING

JAN.

CLO

WORK

RM

AI401

A5

CAVE

170A

ELEV #4

170B

ELEV #5

CORRIDOR

CORRIDOR

OPEN

OFFICE

6' - 4" AFF

8' - 1 1/2" AFF

A1

AI435

9' - 0" AFF

E Q

E Q

BOTTOM OF SHAFT

ENCLOSURE ABOVE

CEILING REFER

TO DETAIL D6/AI504

E Q

E Q

T Y

P

TYP

1' - 0"

TYP

1' - 0"

8"

/2

TYP

1' - 0"

EQ 6' - 0" EQ EQ 6' - 0" EQ

E Q

E Q

EQ EQ

EQ 6' - 5 1/2" EQ

E Q

E Q

EQ 6' - 0" EQ

E Q

E Q

E Q

E Q

3' - 10" 7' - 0"

EQ 7' - 0" EQ

EQ EQ

E Q

E Q

/2

8 1/2"

106B

FEMALE

TOILET

106A

MALE

TOILET

EQ 8' - 0" EQ

ALIGN

CORRIDOR

ALIGN

ALIGN

EQ EQ

EQ EQ

EQ EQ

1' - 6"

E Q

E Q

A L

IG

N

V

IF

2' - 0"

V

IF

ACT-1

ACT-1

ACT-6

2' - 0"

REFLECTED CEILING PLAN LEGEND

LINEAR LIGHT FIXTURE

LINEAR PENDANT LIGHT FIXTURE

DOWN LIGHT FIXTURE

EXIT SIGN

SPEAKER

ACOUSTICAL CEILING TILE

SIZE VARIES REFER TO IN DRAWING SERIES

CEILING BAFFLES

SIZE VARIES REFER TO IN DRAWING SERIES

GYPSUM BOARD CEILING

EXPOSED

2 HOUR FIRE-RATED GYPSUM

BOARD SHAFT ENCLOSURE CEILING

FORMED METAL PANEL (FMP-1)

EXPANSION JOINT COVER (EJ-2)

TUBE LIGHT FIXTURE

ADD SUPPLEMENTAL BACKER ABOVE

CEILING. REFER TO SPECIFICATION 09 51 00.

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

C A

T E

G O

R Y

C O

D E

C:\rvt\2019\10053876-A-MCA2-Central_HHEILE.rvt

1/7/2021 10:10:32 AM READY TO ADVERTISE (RTA)

AC101B

MCA2

A R

C H

IT

E

C T

U R

A L

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

L E

V E

L

A

R E

A B

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

A D

R A

K E

J K

R

IS

S O

F F

D H

O F

M A

N N

H E

Z Z

E D

D

IN

E

N O

V E

M B

E R

W H

N B

-- 1 -3

-0

S C

I M

IS

S

IO

N

C O

M M

A N

D U

N

IV

E R

S

IT

Y R

E G

IS

T

R A

R F

O R

C E

M O

D E

R N

IZ

A

T

IO

N A

N D

P R

O P

O N

E N

C Y

F Y

P

N

NORTH

KEY PLAN

A

C

D

EF

B

8'4' 16'0

SCALE: 1/8"=1'-0"

1/8" = 1'-0" A1

RCP - LEVEL 1 - AREA B

15. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED AND GWB CEILINGS SHALL BE CENTERED AND

EQUALLY SPACED ON EXTENTS UNLESS NOTED

OTHERWISE.

14. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED CEILINGS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

13. FOR ALL ACT CEILINGS THAT MEET AN EXPOSED

STRUCTURAL COLUMN END CEILING 1" FROM THE FACE OF

FLANGES WITH PERIMETER TRIM REFER TO E7/AI521.

12 ALIGN BULKHEADS WITH COLUMN FURRINGS OR EDGES,

UNLESS OTHERWISE NOTED.

11 PROVIDE ROLLER SHADES AT ALL EXTERIOR GLAZING,

EXCEPT AT STAIRS AND GLAZING BETWEEN GRIDS 6 AND 7

ON LEVELS 1 AND 2.

10. FOR ALL SUSPENDED CEILING ELEMENTS THAT DO NOT

TERMINATE AT A WALL PAINT EXPOSED CEILING ABOVE A

MINIMUM OF 3’-0” FROM EACH FACE OF PERIMETER TRIM

WITH PT-5 UNLESS NOTED OTHERWISE.

9. ALL SUSPENDED ACT CEIILNG ELEMENTS THAT DO NOT

TERMINATE AT A WALL REFER TO E8/AI521 PERIMETER TRIM

DETAILS.

8. REFERENCE TYPICAL CEILING DETAILS FOR CEILING

PERIMETER AND CONTROL JOINT DETAILS.

7. REFER TO MILLWORK DRAWINGS AND ELECTRICAL PLANS

FOR INTEGRATED LIGHTING.

6. UNLESS NOTED OTHERWISE, ALL DIMENSIONS TO LIGHT

FIXTURES ARE TO: -FIXTURE CENTERLINES: - COLUMN

CENTERLINES: - FACE OF GWB: - FACE OF MASONRY: - FACE

OF CONCRETE.

5. CENTER CEILNG LIGHTS, SPRINKLER HEADS, AND OTHER

CEILING MOUNTED DEVICES (RECESSED OR SURFACE

MOUNTING) IN CEILING TILE EXTENTS UNLESS NOTED

OTHERWISE.

4. LAY-IN CEILING PANELS SHALL NOT BE SMALLER THAN 6"

WIDE, TYPICAL.

3. CENTER CEILING TILES IN ROOM OR CENTER CEILING GRID

TO THE CENTER OF ROOM, UNLESS NOTED OTHERWISE.

2. REFER TO FINISH PLANS FOR CEILING TYPES AND FINISHES.

1. ALL CEILNG HEIGHTS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

REFLECTED CEILING PLAN

GENERAL NOTES

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/0

/2

H J K

LOBBY

CORRIDOR

STAIR #4

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

STAIR #3

J.4H.6

MATCHLINE - SEE:AC101B

MATCHLINE - SEE:AC101D

PROCESSING

STORAGE

AI441A

A1

C O

R R

ID

O

R

C O

R R

ID

O

R

V E

S T

IB

U

L E

V E

S T

IB

U

L E

9' - 0" AFF

EQ EQ

BOTTOM OF SHAFT

ENCLOSURE REFER

TO DETAIL D6/AI504

EQ 8'-0" 8'-0" 8'-0" EQ

1' - 0" 1' - 0"4"4"

REFLECTED CEILING PLAN LEGEND

LINEAR LIGHT FIXTURE

LINEAR PENDANT LIGHT FIXTURE

DOWN LIGHT FIXTURE

EXIT SIGN

SPEAKER

ACOUSTICAL CEILING TILE

SIZE VARIES REFER TO IN DRAWING SERIES

CEILING BAFFLES

SIZE VARIES REFER TO IN DRAWING SERIES

GYPSUM BOARD CEILING

EXPOSED

2 HOUR FIRE-RATED GYPSUM

BOARD SHAFT ENCLOSURE CEILING

FORMED METAL PANEL (FMP-1)

EXPANSION JOINT COVER (EJ-2)

TUBE LIGHT FIXTURE

ADD SUPPLEMENTAL BACKER ABOVE

CEILING. REFER TO SPECIFICATION 09 51 00.

KEYNOTES - RCP

PROVIDE BRACING AT ALL MONITOR LOCATIONS

ACCORDING TO OWNER SPECIFICATIONS.

1.

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

C A

T E

G O

R Y

C O

D E

C:\rvt\2019\10053876-A-MCA2-Central_HHEILE.rvt

1/7/2021 10:10:39 AM READY TO ADVERTISE (RTA)

AC101C

MCA2

A R

C H

IT

E

C T

U R

A L

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

L E

V E

L

A

R E

A C

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

A D

R A

K E

J K

R

IS

S O

F F

D H

O F

M A

N N

H E

Z Z

E D

D

IN

E

N O

V E

M B

E R

W H

N B

-- 1 -3

-0

S C

I M

IS

S

IO

N

C O

M M

A N

D U

N

IV

E R

S

IT

Y R

E G

IS

T

R A

R F

O R

C E

M O

D E

R N

IZ

A

T

IO

N A

N D

P R

O P

O N

E N

C Y

F Y

P

N

NORTH

KEY PLAN

A

C

D

EF

B

8'4' 16'0

SCALE: 1/8"=1'-0"

1/8" = 1'-0" A1

RCP - LEVEL 1 - AREA C

15. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED AND GWB CEILINGS SHALL BE CENTERED AND

EQUALLY SPACED ON EXTENTS UNLESS NOTED

OTHERWISE.

14. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED CEILINGS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

13. FOR ALL ACT CEILINGS THAT MEET AN EXPOSED

STRUCTURAL COLUMN END CEILING 1" FROM THE FACE OF

FLANGES WITH PERIMETER TRIM REFER TO E7/AI521.

12 ALIGN BULKHEADS WITH COLUMN FURRINGS OR EDGES,

UNLESS OTHERWISE NOTED.

11 PROVIDE ROLLER SHADES AT ALL EXTERIOR GLAZING,

EXCEPT AT STAIRS AND GLAZING BETWEEN GRIDS 6 AND 7

ON LEVELS 1 AND 2.

10. FOR ALL SUSPENDED CEILING ELEMENTS THAT DO NOT

TERMINATE AT A WALL PAINT EXPOSED CEILING ABOVE A

MINIMUM OF 3’-0” FROM EACH FACE OF PERIMETER TRIM

WITH PT-5 UNLESS NOTED OTHERWISE.

9. ALL SUSPENDED ACT CEIILNG ELEMENTS THAT DO NOT

TERMINATE AT A WALL REFER TO E8/AI521 PERIMETER TRIM

DETAILS.

8. REFERENCE TYPICAL CEILING DETAILS FOR CEILING

PERIMETER AND CONTROL JOINT DETAILS.

7. REFER TO MILLWORK DRAWINGS AND ELECTRICAL PLANS

FOR INTEGRATED LIGHTING.

6. UNLESS NOTED OTHERWISE, ALL DIMENSIONS TO LIGHT

FIXTURES ARE TO: -FIXTURE CENTERLINES: - COLUMN

CENTERLINES: - FACE OF GWB: - FACE OF MASONRY: - FACE

OF CONCRETE.

5. CENTER CEILNG LIGHTS, SPRINKLER HEADS, AND OTHER

CEILING MOUNTED DEVICES (RECESSED OR SURFACE

MOUNTING) IN CEILING TILE EXTENTS UNLESS NOTED

OTHERWISE.

4. LAY-IN CEILING PANELS SHALL NOT BE SMALLER THAN 6"

WIDE, TYPICAL.

3. CENTER CEILING TILES IN ROOM OR CENTER CEILING GRID

TO THE CENTER OF ROOM, UNLESS NOTED OTHERWISE.

2. REFER TO FINISH PLANS FOR CEILING TYPES AND FINISHES.

1. ALL CEILNG HEIGHTS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

REFLECTED CEILING PLAN

GENERAL NOTES

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/0

/2

LAB

LAB

LAB

LAB

INSTRUCTOR

MATCHLINE - SEE:AC101C

MATCHLINE - SEE:AC101E

STUDENT

BREAK

JAN.

CLO.

CAVE

ELEC

TELECOM

AI403

D1

STAIR #3

STUDENT

COPY/PRINT

C O

R R

ID

O

R

CORRIDOR

8' - 1 1/2" AFF

A5

AI435

8' - 6" AFF

BOTTOM OF SHAFT

ENCLOSURE REFER

TO DETAIL D6/AI504

C O

R R

ID

O

R

A L

IG

N

E Q

E Q

EQ EQ

EQ 6' - 6" EQ

EQ EQE

Q

E Q

EQ EQ

122B

FEMALE

TOILET

122A

MALE

TOILET

4" 4"

E Q

E Q

1'-0" 4" 1'-0"4"

A L

IG

N120A

ELEV #2

120B

ELEV #3

8' - 0" AFF

BOTTOM OF SHAFT

ENCLOSURE ABOVE

CEILING REFER

TO DETAIL D6/AI504

REFLECTED CEILING PLAN LEGEND

LINEAR LIGHT FIXTURE

LINEAR PENDANT LIGHT FIXTURE

DOWN LIGHT FIXTURE

EXIT SIGN

SPEAKER

ACOUSTICAL CEILING TILE

SIZE VARIES REFER TO IN DRAWING SERIES

CEILING BAFFLES

SIZE VARIES REFER TO IN DRAWING SERIES

GYPSUM BOARD CEILING

EXPOSED

2 HOUR FIRE-RATED GYPSUM

BOARD SHAFT ENCLOSURE CEILING

FORMED METAL PANEL (FMP-1)

EXPANSION JOINT COVER (EJ-2)

TUBE LIGHT FIXTURE

ADD SUPPLEMENTAL BACKER ABOVE

CEILING. REFER TO SPECIFICATION 09 51 00.

KEYNOTES - RCP

PROVIDE BRACING AT ALL MONITOR LOCATIONS

ACCORDING TO OWNER SPECIFICATIONS.

1.

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

C A

T E

G O

R Y

C O

D E

C:\rvt\2019\10053876-A-MCA2-Central_HHEILE.rvt

1/7/2021 10:10:46 AM READY TO ADVERTISE (RTA)

AC101D

MCA2

A R

C H

IT

E

C T

U R

A L

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

L E

V E

L

A

R E

A D

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

A D

R A

K E

J K

R

IS

S O

F F

D H

O F

M A

N N

H E

Z Z

E D

D

IN

E

N O

V E

M B

E R

W H

N B

-- 1 -3

-0

S C

I M

IS

S

IO

N

C O

M M

A N

D U

N

IV

E R

S

IT

Y R

E G

IS

T

R A

R F

O R

C E

M O

D E

R N

IZ

A

T

IO

N A

N D

P R

O P

O N

E N

C Y

F Y

P

N

NORTH

KEY PLAN

A

C

D

EF

B

8'4' 16'0

SCALE: 1/8"=1'-0"

1/8" = 1'-0" A1

RCP - LEVEL 1 - AREA D

15. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED AND GWB CEILINGS SHALL BE CENTERED AND

EQUALLY SPACED ON EXTENTS UNLESS NOTED

OTHERWISE.

14. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED CEILINGS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

13. FOR ALL ACT CEILINGS THAT MEET AN EXPOSED

STRUCTURAL COLUMN END CEILING 1" FROM THE FACE OF

FLANGES WITH PERIMETER TRIM REFER TO E7/AI521.

12 ALIGN BULKHEADS WITH COLUMN FURRINGS OR EDGES,

UNLESS OTHERWISE NOTED.

11 PROVIDE ROLLER SHADES AT ALL EXTERIOR GLAZING,

EXCEPT AT STAIRS AND GLAZING BETWEEN GRIDS 6 AND 7

ON LEVELS 1 AND 2.

10. FOR ALL SUSPENDED CEILING ELEMENTS THAT DO NOT

TERMINATE AT A WALL PAINT EXPOSED CEILING ABOVE A

MINIMUM OF 3’-0” FROM EACH FACE OF PERIMETER TRIM

WITH PT-5 UNLESS NOTED OTHERWISE.

9. ALL SUSPENDED ACT CEIILNG ELEMENTS THAT DO NOT

TERMINATE AT A WALL REFER TO E8/AI521 PERIMETER TRIM

DETAILS.

8. REFERENCE TYPICAL CEILING DETAILS FOR CEILING

PERIMETER AND CONTROL JOINT DETAILS.

7. REFER TO MILLWORK DRAWINGS AND ELECTRICAL PLANS

FOR INTEGRATED LIGHTING.

6. UNLESS NOTED OTHERWISE, ALL DIMENSIONS TO LIGHT

FIXTURES ARE TO: -FIXTURE CENTERLINES: - COLUMN

CENTERLINES: - FACE OF GWB: - FACE OF MASONRY: - FACE

OF CONCRETE.

5. CENTER CEILNG LIGHTS, SPRINKLER HEADS, AND OTHER

CEILING MOUNTED DEVICES (RECESSED OR SURFACE

MOUNTING) IN CEILING TILE EXTENTS UNLESS NOTED

OTHERWISE.

4. LAY-IN CEILING PANELS SHALL NOT BE SMALLER THAN 6"

WIDE, TYPICAL.

3. CENTER CEILING TILES IN ROOM OR CENTER CEILING GRID

TO THE CENTER OF ROOM, UNLESS NOTED OTHERWISE.

2. REFER TO FINISH PLANS FOR CEILING TYPES AND FINISHES.

1. ALL CEILNG HEIGHTS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

REFLECTED CEILING PLAN

GENERAL NOTES

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/0

/2

FD G

STORAGE

ELEC

LOADING

DOCK

STAIR #2

ELEC

TELECOM

MECH

STORAGE

CAVE

FIRE

PUMP

E

ELEV #1

LAB

LAB

MATCHLINE - SEE:AC101D

M A

T C

H

LI

N E

S

E E

:A C

1F

AI404

A4

163A

TER

BEF

C O

R R

ID

O

R

CORRIDOR

CORRIDOR

8 1/2"

E Q

E

QEQ EQ

E Q

E

Q

EQ 6' - 0" EQ

E Q

E Q

ALIGN ALIGN

A L

IG

N

E Q

E Q

EQ 9' - 0" 9' - 0" 9' - 0" 9' - 0" EQ

E Q

E Q

EQ 10' - 4" 10' - 4" EQ EQ EQ

E Q

E Q

E Q

E Q

E Q

E Q

EQ 11' - 0" 11' - 0" 11' - 0" EQ

EQ 5' - 0" EQ EQ EQ

E Q

E Q

1'-0" 4" 1'-0"

C O

R R

ID

O

R

C O

R R

ID

O

R

ALIGN4

EQ

2' - 6"

EQ

156A

MALE

TOILET

156B

FEMALE

TOILET

ALIGN

B.O.S ENCLOSURE

REFER TO DETAIL

D6/AI504

A8

AI435

4' - 1" 18' - 3"

7' - 3"

165A

INVERTER

E Q

E Q

EQ EQ

4' - 1" 9' - 5" 8' - 10" 4' - 7"

3' - 6"

4"

REFLECTED CEILING PLAN LEGEND

LINEAR LIGHT FIXTURE

LINEAR PENDANT LIGHT FIXTURE

DOWN LIGHT FIXTURE

EXIT SIGN

SPEAKER

ACOUSTICAL CEILING TILE

SIZE VARIES REFER TO IN DRAWING SERIES

CEILING BAFFLES

SIZE VARIES REFER TO IN DRAWING SERIES

GYPSUM BOARD CEILING

EXPOSED

2 HOUR FIRE-RATED GYPSUM

BOARD SHAFT ENCLOSURE CEILING

FORMED METAL PANEL (FMP-1)

EXPANSION JOINT COVER (EJ-2)

TUBE LIGHT FIXTURE

ADD SUPPLEMENTAL BACKER ABOVE

CEILING. REFER TO SPECIFICATION 09 51 00.

KEYNOTES - RCP

PROVIDE BRACING AT ALL MONITOR LOCATIONS

ACCORDING TO OWNER SPECIFICATIONS.

1.

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

C A

T E

G O

R Y

C O

D E

C:\rvt\2019\10053876-A-MCA2-Central_HHEILE.rvt

1/7/2021 10:10:53 AM READY TO ADVERTISE (RTA)

AC101E

MCA2

A R

C H

IT

E

C T

U R

A L

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

L E

V E

L

A

R E

A E

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

A D

R A

K E

J K

R

IS

S O

F F

D H

O F

M A

N N

H E

Z Z

E D

D

IN

E

N O

V E

M B

E R

W H

N B

-- 1 -3

-0

S C

I M

IS

S

IO

N

C O

M M

A N

D U

N

IV

E R

S

IT

Y R

E G

IS

T

R A

R F

O R

C E

M O

D E

R N

IZ

A

T

IO

N A

N D

P R

O P

O N

E N

C Y

F Y

P

N

NORTH

KEY PLAN

A

C

D

EF

B

8'4' 16'0

SCALE: 1/8"=1'-0"

1/8" = 1'-0" A1

RCP - LEVEL 1 - AREA E

15. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED AND GWB CEILINGS SHALL BE CENTERED AND

EQUALLY SPACED ON EXTENTS UNLESS NOTED

OTHERWISE.

14. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED CEILINGS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

13. FOR ALL ACT CEILINGS THAT MEET AN EXPOSED

STRUCTURAL COLUMN END CEILING 1" FROM THE FACE OF

FLANGES WITH PERIMETER TRIM REFER TO E7/AI521.

12 ALIGN BULKHEADS WITH COLUMN FURRINGS OR EDGES,

UNLESS OTHERWISE NOTED.

11 PROVIDE ROLLER SHADES AT ALL EXTERIOR GLAZING,

EXCEPT AT STAIRS AND GLAZING BETWEEN GRIDS 6 AND 7

ON LEVELS 1 AND 2.

10. FOR ALL SUSPENDED CEILING ELEMENTS THAT DO NOT

TERMINATE AT A WALL PAINT EXPOSED CEILING ABOVE A

MINIMUM OF 3’-0” FROM EACH FACE OF PERIMETER TRIM

WITH PT-5 UNLESS NOTED OTHERWISE.

9. ALL SUSPENDED ACT CEIILNG ELEMENTS THAT DO NOT

TERMINATE AT A WALL REFER TO E8/AI521 PERIMETER TRIM

DETAILS.

8. REFERENCE TYPICAL CEILING DETAILS FOR CEILING

PERIMETER AND CONTROL JOINT DETAILS.

7. REFER TO MILLWORK DRAWINGS AND ELECTRICAL PLANS

FOR INTEGRATED LIGHTING.

6. UNLESS NOTED OTHERWISE, ALL DIMENSIONS TO LIGHT

FIXTURES ARE TO: -FIXTURE CENTERLINES: - COLUMN

CENTERLINES: - FACE OF GWB: - FACE OF MASONRY: - FACE

OF CONCRETE.

5. CENTER CEILNG LIGHTS, SPRINKLER HEADS, AND OTHER

CEILING MOUNTED DEVICES (RECESSED OR SURFACE

MOUNTING) IN CEILING TILE EXTENTS UNLESS NOTED

OTHERWISE.

4. LAY-IN CEILING PANELS SHALL NOT BE SMALLER THAN 6"

WIDE, TYPICAL.

3. CENTER CEILING TILES IN ROOM OR CENTER CEILING GRID

TO THE CENTER OF ROOM, UNLESS NOTED OTHERWISE.

2. REFER TO FINISH PLANS FOR CEILING TYPES AND FINISHES.

1. ALL CEILNG HEIGHTS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

REFLECTED CEILING PLAN

GENERAL NOTES

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/0

/2

A

A

B

B

C

C

D

D

LAB

STAIR #1

M A

T C

H

LI

N E

S

E E

:A C

E

LAB

LAB

LAB

INSTRUCTOR

CORRIDOR

C O

R R

ID

O

R

CORRIDOR

17.6

18.3

A.4

16.8

ALIGN

ALIGN

A L

IG

N

E Q

E Q

2' - 3"

STAFF

BREAK

8' - 1 1/2" AFF

4"

END CEILING GRID

ON A FULL TILE.

6' - 4" AFF

REFLECTED CEILING PLAN LEGEND

LINEAR LIGHT FIXTURE

LINEAR PENDANT LIGHT FIXTURE

DOWN LIGHT FIXTURE

EXIT SIGN

SPEAKER

ACOUSTICAL CEILING TILE

SIZE VARIES REFER TO IN DRAWING SERIES

CEILING BAFFLES

SIZE VARIES REFER TO IN DRAWING SERIES

GYPSUM BOARD CEILING

EXPOSED

2 HOUR FIRE-RATED GYPSUM

BOARD SHAFT ENCLOSURE CEILING

FORMED METAL PANEL (FMP-1)

EXPANSION JOINT COVER (EJ-2)

TUBE LIGHT FIXTURE

ADD SUPPLEMENTAL BACKER ABOVE

CEILING. REFER TO SPECIFICATION 09 51 00.

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

C A

T E

G O

R Y

C O

D E

C:\rvt\2019\10053876-A-MCA2-Central_HHEILE.rvt

1/7/2021 10:10:59 AM READY TO ADVERTISE (RTA)

AC101F

MCA2

A R

C H

IT

E

C T

U R

A L

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

L E

V E

L

A

R E

A F

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

A D

R A

K E

J K

R

IS

S O

F F

D H

O F

M A

N N

H E

Z Z

E D

D

IN

E

N O

V E

M B

E R

W H

N B

-- 1 -3

-0

S C

I M

IS

S

IO

N

C O

M M

A N

D U

N

IV

E R

S

IT

Y R

E G

IS

T

R A

R F

O R

C E

M O

D E

R N

IZ

A

T

IO

N A

N D

P R

O P

O N

E N

C Y

F Y

P

N

NORTH

KEY PLAN

A

C

D

EF

B

8'4' 16'0

SCALE: 1/8"=1'-0"

1/8" = 1'-0" A1

RCP - LEVEL 1 - AREA F

15. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED AND GWB CEILINGS SHALL BE CENTERED AND

EQUALLY SPACED ON EXTENTS UNLESS NOTED

OTHERWISE.

14. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED CEILINGS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

13. FOR ALL ACT CEILINGS THAT MEET AN EXPOSED

STRUCTURAL COLUMN END CEILING 1" FROM THE FACE OF

FLANGES WITH PERIMETER TRIM REFER TO E7/AI521.

12 ALIGN BULKHEADS WITH COLUMN FURRINGS OR EDGES,

UNLESS OTHERWISE NOTED.

11 PROVIDE ROLLER SHADES AT ALL EXTERIOR GLAZING,

EXCEPT AT STAIRS AND GLAZING BETWEEN GRIDS 6 AND 7

ON LEVELS 1 AND 2.

10. FOR ALL SUSPENDED CEILING ELEMENTS THAT DO NOT

TERMINATE AT A WALL PAINT EXPOSED CEILING ABOVE A

MINIMUM OF 3’-0” FROM EACH FACE OF PERIMETER TRIM

WITH PT-5 UNLESS NOTED OTHERWISE.

9. ALL SUSPENDED ACT CEIILNG ELEMENTS THAT DO NOT

TERMINATE AT A WALL REFER TO E8/AI521 PERIMETER TRIM

DETAILS.

8. REFERENCE TYPICAL CEILING DETAILS FOR CEILING

PERIMETER AND CONTROL JOINT DETAILS.

7. REFER TO MILLWORK DRAWINGS AND ELECTRICAL PLANS

FOR INTEGRATED LIGHTING.

6. UNLESS NOTED OTHERWISE, ALL DIMENSIONS TO LIGHT

FIXTURES ARE TO: -FIXTURE CENTERLINES: - COLUMN

CENTERLINES: - FACE OF GWB: - FACE OF MASONRY: - FACE

OF CONCRETE.

5. CENTER CEILNG LIGHTS, SPRINKLER HEADS, AND OTHER

CEILING MOUNTED DEVICES (RECESSED OR SURFACE

MOUNTING) IN CEILING TILE EXTENTS UNLESS NOTED

OTHERWISE.

4. LAY-IN CEILING PANELS SHALL NOT BE SMALLER THAN 6"

WIDE, TYPICAL.

3. CENTER CEILING TILES IN ROOM OR CENTER CEILING GRID

TO THE CENTER OF ROOM, UNLESS NOTED OTHERWISE.

2. REFER TO FINISH PLANS FOR CEILING TYPES AND FINISHES.

1. ALL CEILNG HEIGHTS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

REFLECTED CEILING PLAN

GENERAL NOTES

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/0

/2

TSRQ

STAIR #5

CONFERENCE

8-10 PN

DIRECTOR

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

M A

T C

H

LI

N E

S

E E

:A C

B

OPEN

OFFICE TYP

8 1/2"

TYP

1' - 0" 8 1/2"

8"

/2

4"

ALIGN

A L

IG

N A

L

IG

N

ALIGN

/2

TYP

1' - 0"

VIF

V

IF

ACT-3

2' - 0"

ACT-4 4

2' - 0"

ACT-6

V

IFACT-6

2' - 0"

REFLECTED CEILING PLAN LEGEND

LINEAR LIGHT FIXTURE

LINEAR PENDANT LIGHT FIXTURE

DOWN LIGHT FIXTURE

EXIT SIGN

SPEAKER

ACOUSTICAL CEILING TILE

SIZE VARIES REFER TO IN DRAWING SERIES

CEILING BAFFLES

SIZE VARIES REFER TO IN DRAWING SERIES

GYPSUM BOARD CEILING

EXPOSED

2 HOUR FIRE-RATED GYPSUM

BOARD SHAFT ENCLOSURE CEILING

FORMED METAL PANEL (FMP-1)

EXPANSION JOINT COVER (EJ-2)

TUBE LIGHT FIXTURE

ADD SUPPLEMENTAL BACKER ABOVE

CEILING. REFER TO SPECIFICATION 09 51 00.

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

C A

T E

G O

R Y

C O

D E

C:\rvt\2019\10053876-A-MCA2-Central_HHEILE.rvt

1/7/2021 10:11:05 AM READY TO ADVERTISE (RTA)

AC102A

MCA2

A R

C H

IT

E

C T

U R

A L

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

L E

V E

L

A

R E

A A

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

A D

R A

K E

J K

R

IS

S O

F F

D H

O F

M A

N N

H E

Z Z

E D

D

IN

E

N O

V E

M B

E R

W H

N B

-- 1 -3

-0

S C

I M

IS

S

IO

N

C O

M M

A N

D U

N

IV

E R

S

IT

Y R

E G

IS

T

R A

R F

O R

C E

M O

D E

R N

IZ

A

T

IO

N A

N D

P R

O P

O N

E N

C Y

F Y

P

N

NORTH

KEY PLAN

A

C

D

EF

B

8'4' 16'0

SCALE: 1/8"=1'-0"

1/8" = 1'-0" A1

RCP - LEVEL 2 - AREA A

15. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED AND GWB CEILINGS SHALL BE CENTERED AND

EQUALLY SPACED ON EXTENTS UNLESS NOTED

OTHERWISE.

14. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED CEILINGS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

13. FOR ALL ACT CEILINGS THAT MEET AN EXPOSED

STRUCTURAL COLUMN END CEILING 1" FROM THE FACE OF

FLANGES WITH PERIMETER TRIM REFER TO E7/AI521.

12 ALIGN BULKHEADS WITH COLUMN FURRINGS OR EDGES,

UNLESS OTHERWISE NOTED.

11 PROVIDE ROLLER SHADES AT ALL EXTERIOR GLAZING,

EXCEPT AT STAIRS AND GLAZING BETWEEN GRIDS 6 AND 7

ON LEVELS 1 AND 2.

10. FOR ALL SUSPENDED CEILING ELEMENTS THAT DO NOT

TERMINATE AT A WALL PAINT EXPOSED CEILING ABOVE A

MINIMUM OF 3’-0” FROM EACH FACE OF PERIMETER TRIM

WITH PT-5 UNLESS NOTED OTHERWISE.

9. ALL SUSPENDED ACT CEIILNG ELEMENTS THAT DO NOT

TERMINATE AT A WALL REFER TO E8/AI521 PERIMETER TRIM

DETAILS.

8. REFERENCE TYPICAL CEILING DETAILS FOR CEILING

PERIMETER AND CONTROL JOINT DETAILS.

7. REFER TO MILLWORK DRAWINGS AND ELECTRICAL PLANS

FOR INTEGRATED LIGHTING.

6. UNLESS NOTED OTHERWISE, ALL DIMENSIONS TO LIGHT

FIXTURES ARE TO: -FIXTURE CENTERLINES: - COLUMN

CENTERLINES: - FACE OF GWB: - FACE OF MASONRY: - FACE

OF CONCRETE.

5. CENTER CEILNG LIGHTS, SPRINKLER HEADS, AND OTHER

CEILING MOUNTED DEVICES (RECESSED OR SURFACE

MOUNTING) IN CEILING TILE EXTENTS UNLESS NOTED

OTHERWISE.

4. LAY-IN CEILING PANELS SHALL NOT BE SMALLER THAN 6"

WIDE, TYPICAL.

3. CENTER CEILING TILES IN ROOM OR CENTER CEILING GRID

TO THE CENTER OF ROOM, UNLESS NOTED OTHERWISE.

2. REFER TO FINISH PLANS FOR CEILING TYPES AND FINISHES.

1. ALL CEILNG HEIGHTS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

REFLECTED CEILING PLAN

GENERAL NOTES

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/0

/2

H K

M N P

STAIR #4 208

STAFF

BREAK

CAVE

J.4H.6

MATCHLINE - SEE:AC102C

M A

T C

H

LI

N E

S

E E

:A C

A

MECH

JAN.

CLO

CONFERENCE

20-30 PN

WORK/COPY

TELECOM

ELEC

STORAGE

HELP

DESK

AI402

A5

STORAGE

CAVE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OPEN

OFFICE

COLLAB

CORRIDOR

271A

CORRIDOR

270A

ELEV #4

270B

ELEV #5

CORRIDOR

8' - 0" AFF

/2

8"

TYP

1' - 0"

8 1/2"

T Y

P

/2

E Q

E Q

6' - 4" AFF

8' - 1 1/2" AFF

EQ EQ

E Q

E Q

EQ EQ EQ 6' - 4" EQ

8' - 0" 8' - 0" 8' - 0" 8' - 0"

EQ EQ

ALIGN

E Q

E Q

EQ EQ

E Q

E Q

EQ 5' - 6" 5' - 6" EQ

EQ EQE

Q

E Q

E Q

E Q

EQ 7' - 4" EQ

EQ 8' - 0" EQ

E Q

E Q

/2

8 1/2"

206B

FEMALE

TOILET

206A

MALE

TOILET

CORRIDOR

EQ 8' - 0" EQ

" ALIGN ALIGN

ALIGN

ALIGN8"

A L

IG

N

ALIGN

4"

A L

IG

N

A L

IG

N 7"

T Y

P

6"

2' - 0"

V

IF

ACT-4

ACT-3

ACT-7

VIF

V

IF ACT-6

2' - 0"

ACT-1

2' - 0"

REFLECTED CEILING PLAN LEGEND

LINEAR LIGHT FIXTURE

LINEAR PENDANT LIGHT FIXTURE

DOWN LIGHT FIXTURE

EXIT SIGN

SPEAKER

ACOUSTICAL CEILING TILE

SIZE VARIES REFER TO IN DRAWING SERIES

CEILING BAFFLES

SIZE VARIES REFER TO IN DRAWING SERIES

GYPSUM BOARD CEILING

EXPOSED

2 HOUR FIRE-RATED GYPSUM

BOARD SHAFT ENCLOSURE CEILING

FORMED METAL PANEL (FMP-1)

EXPANSION JOINT COVER (EJ-2)

TUBE LIGHT FIXTURE

ADD SUPPLEMENTAL BACKER ABOVE

CEILING. REFER TO SPECIFICATION 09 51 00.

KEYNOTES - RCP

PROVIDE BRACING AT ALL MONITOR LOCATIONS

ACCORDING TO OWNER SPECIFICATIONS.

1.

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

C A

T E

G O

R Y

C O

D E

C:\rvt\2019\10053876-A-MCA2-Central_HHEILE.rvt

1/7/2021 10:11:12 AM READY TO ADVERTISE (RTA)

AC102B

MCA2

A R

C H

IT

E

C T

U R

A L

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

L E

V E

L

A

R E

A B

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

A D

R A

K E

J K

R

IS

S O

F F

D H

O F

M A

N N

H E

Z Z

E D

D

IN

E

N O

V E

M B

E R

W H

N B

-- 1 -3

-0

S C

I M

IS

S

IO

N

C O

M M

A N

D U

N

IV

E R

S

IT

Y R

E G

IS

T

R A

R F

O R

C E

M O

D E

R N

IZ

A

T

IO

N A

N D

P R

O P

O N

E N

C Y

F Y

P

N

NORTH

KEY PLAN

A

C

D

EF

B

8'4' 16'0

SCALE: 1/8"=1'-0"

1/8" = 1'-0" A1

RCP - LEVEL 2 - AREA B

15. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED AND GWB CEILINGS SHALL BE CENTERED AND

EQUALLY SPACED ON EXTENTS UNLESS NOTED

OTHERWISE.

14. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED CEILINGS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

13. FOR ALL ACT CEILINGS THAT MEET AN EXPOSED

STRUCTURAL COLUMN END CEILING 1" FROM THE FACE OF

FLANGES WITH PERIMETER TRIM REFER TO E7/AI521.

12 ALIGN BULKHEADS WITH COLUMN FURRINGS OR EDGES,

UNLESS OTHERWISE NOTED.

11 PROVIDE ROLLER SHADES AT ALL EXTERIOR GLAZING,

EXCEPT AT STAIRS AND GLAZING BETWEEN GRIDS 6 AND 7

ON LEVELS 1 AND 2.

10. FOR ALL SUSPENDED CEILING ELEMENTS THAT DO NOT

TERMINATE AT A WALL PAINT EXPOSED CEILING ABOVE A

MINIMUM OF 3’-0” FROM EACH FACE OF PERIMETER TRIM

WITH PT-5 UNLESS NOTED OTHERWISE.

9. ALL SUSPENDED ACT CEIILNG ELEMENTS THAT DO NOT

TERMINATE AT A WALL REFER TO E8/AI521 PERIMETER TRIM

DETAILS.

8. REFERENCE TYPICAL CEILING DETAILS FOR CEILING

PERIMETER AND CONTROL JOINT DETAILS.

7. REFER TO MILLWORK DRAWINGS AND ELECTRICAL PLANS

FOR INTEGRATED LIGHTING.

6. UNLESS NOTED OTHERWISE, ALL DIMENSIONS TO LIGHT

FIXTURES ARE TO: -FIXTURE CENTERLINES: - COLUMN

CENTERLINES: - FACE OF GWB: - FACE OF MASONRY: - FACE

OF CONCRETE.

5. CENTER CEILNG LIGHTS, SPRINKLER HEADS, AND OTHER

CEILING MOUNTED DEVICES (RECESSED OR SURFACE

MOUNTING) IN CEILING TILE EXTENTS UNLESS NOTED

OTHERWISE.

4. LAY-IN CEILING PANELS SHALL NOT BE SMALLER THAN 6"

WIDE, TYPICAL.

3. CENTER CEILING TILES IN ROOM OR CENTER CEILING GRID

TO THE CENTER OF ROOM, UNLESS NOTED OTHERWISE.

2. REFER TO FINISH PLANS FOR CEILING TYPES AND FINISHES.

1. ALL CEILNG HEIGHTS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

REFLECTED CEILING PLAN

GENERAL NOTES

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/0

/2

CLASSROOM

J.4H.6

MATCHLINE - SEE:AC102B

MATCHLINE - SEE:AC102D

CLASSROOM

CLASSROOM

CLASSROOM

C O

R R

ID

O

R

C O

R R

ID

O

R

STORAGE

AI441B

A1

CORRIDOR

C O

R R

ID

O

R

C O

R R

ID

O

R

STAIR #3

EQ 10' - 0" 10' - 0" EQ

E Q

E Q

1' - 0" 1' - 0"4" 4"

REFLECTED CEILING PLAN LEGEND

LINEAR LIGHT FIXTURE

LINEAR PENDANT LIGHT FIXTURE

DOWN LIGHT FIXTURE

EXIT SIGN

SPEAKER

ACOUSTICAL CEILING TILE

SIZE VARIES REFER TO IN DRAWING SERIES

CEILING BAFFLES

SIZE VARIES REFER TO IN DRAWING SERIES

GYPSUM BOARD CEILING

EXPOSED

2 HOUR FIRE-RATED GYPSUM

BOARD SHAFT ENCLOSURE CEILING

FORMED METAL PANEL (FMP-1)

EXPANSION JOINT COVER (EJ-2)

TUBE LIGHT FIXTURE

ADD SUPPLEMENTAL BACKER ABOVE

CEILING. REFER TO SPECIFICATION 09 51 00.

KEYNOTES - RCP

PROVIDE BRACING AT ALL MONITOR LOCATIONS

ACCORDING TO OWNER SPECIFICATIONS.

1.

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

C A

T E

G O

R Y

C O

D E

C:\rvt\2019\10053876-A-MCA2-Central_HHEILE.rvt

1/7/2021 10:11:19 AM READY TO ADVERTISE (RTA)

AC102C

MCA2

A R

C H

IT

E

C T

U R

A L

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

L E

V E

L

A

R E

A C

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

A D

R A

K E

J K

R

IS

S O

F F

D H

O F

M A

N N

H E

Z Z

E D

D

IN

E

N O

V E

M B

E R

W H

N B

-- 1 -3

-0

S C

I M

IS

S

IO

N

C O

M M

A N

D U

N

IV

E R

S

IT

Y R

E G

IS

T

R A

R F

O R

C E

M O

D E

R N

IZ

A

T

IO

N A

N D

P R

O P

O N

E N

C Y

F Y

P

N

NORTH

KEY PLAN

A

C

D

EF

B

8'4' 16'0

SCALE: 1/8"=1'-0"

1/8" = 1'-0" A1

RCP - LEVEL 2 - AREA C

15. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED AND GWB CEILINGS SHALL BE CENTERED AND

EQUALLY SPACED ON EXTENTS UNLESS NOTED

OTHERWISE.

14. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED CEILINGS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

13. FOR ALL ACT CEILINGS THAT MEET AN EXPOSED

STRUCTURAL COLUMN END CEILING 1" FROM THE FACE OF

FLANGES WITH PERIMETER TRIM REFER TO E7/AI521.

12 ALIGN BULKHEADS WITH COLUMN FURRINGS OR EDGES,

UNLESS OTHERWISE NOTED.

11 PROVIDE ROLLER SHADES AT ALL EXTERIOR GLAZING,

EXCEPT AT STAIRS AND GLAZING BETWEEN GRIDS 6 AND 7

ON LEVELS 1 AND 2.

10. FOR ALL SUSPENDED CEILING ELEMENTS THAT DO NOT

TERMINATE AT A WALL PAINT EXPOSED CEILING ABOVE A

MINIMUM OF 3’-0” FROM EACH FACE OF PERIMETER TRIM

WITH PT-5 UNLESS NOTED OTHERWISE.

9. ALL SUSPENDED ACT CEIILNG ELEMENTS THAT DO NOT

TERMINATE AT A WALL REFER TO E8/AI521 PERIMETER TRIM

DETAILS.

8. REFERENCE TYPICAL CEILING DETAILS FOR CEILING

PERIMETER AND CONTROL JOINT DETAILS.

7. REFER TO MILLWORK DRAWINGS AND ELECTRICAL PLANS

FOR INTEGRATED LIGHTING.

6. UNLESS NOTED OTHERWISE, ALL DIMENSIONS TO LIGHT

FIXTURES ARE TO: -FIXTURE CENTERLINES: - COLUMN

CENTERLINES: - FACE OF GWB: - FACE OF MASONRY: - FACE

OF CONCRETE.

5. CENTER CEILNG LIGHTS, SPRINKLER HEADS, AND OTHER

CEILING MOUNTED DEVICES (RECESSED OR SURFACE

MOUNTING) IN CEILING TILE EXTENTS UNLESS NOTED

OTHERWISE.

4. LAY-IN CEILING PANELS SHALL NOT BE SMALLER THAN 6"

WIDE, TYPICAL.

3. CENTER CEILING TILES IN ROOM OR CENTER CEILING GRID

TO THE CENTER OF ROOM, UNLESS NOTED OTHERWISE.

2. REFER TO FINISH PLANS FOR CEILING TYPES AND FINISHES.

1. ALL CEILNG HEIGHTS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

REFLECTED CEILING PLAN

GENERAL NOTES

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/0

/2

INSTRUCTOR

MATCHLINE - SEE:AC102C

MATCHLINE - SEE:AC102E

LAB

LAB

LAB

LAB

STUDENT

BREAK

STUDENT

COPY/PRINT

222B

FEMALE

TOILET

JAN.

CLO.

222A

MALE

TOILET

MECH

ELEC

TELECOM

STAIR #3

CORRIDOR

C O

R R

ID

O

R

C O

R R

ID

O

R

Sim

AI403

D1

8' - 1 1/2" AFF

A L

IG

N

E Q

E Q

EQ 6' - 6" EQEQ EQ

4" 4"

E Q

E Q

1'-0" 1'-0"4"

A L

IG

N220A

ELEV #2

220B

ELEV #3

4"

8' - 0" AFF

REFLECTED CEILING PLAN LEGEND

LINEAR LIGHT FIXTURE

LINEAR PENDANT LIGHT FIXTURE

DOWN LIGHT FIXTURE

EXIT SIGN

SPEAKER

ACOUSTICAL CEILING TILE

SIZE VARIES REFER TO IN DRAWING SERIES

CEILING BAFFLES

SIZE VARIES REFER TO IN DRAWING SERIES

GYPSUM BOARD CEILING

EXPOSED

2 HOUR FIRE-RATED GYPSUM

BOARD SHAFT ENCLOSURE CEILING

FORMED METAL PANEL (FMP-1)

EXPANSION JOINT COVER (EJ-2)

TUBE LIGHT FIXTURE

ADD SUPPLEMENTAL BACKER ABOVE

CEILING. REFER TO SPECIFICATION 09 51 00.

KEYNOTES - RCP

PROVIDE BRACING AT ALL MONITOR LOCATIONS

ACCORDING TO OWNER SPECIFICATIONS.

1.

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

C A

T E

G O

R Y

C O

D E

C:\rvt\2019\10053876-A-MCA2-Central_HHEILE.rvt

1/7/2021 10:11:26 AM READY TO ADVERTISE (RTA)

AC102D

MCA2

A R

C H

IT

E

C T

U R

A L

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

L E

V E

L

A

R E

A D

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

A D

R A

K E

J K

R

IS

S O

F F

D H

O F

M A

N N

H E

Z Z

E D

D

IN

E

N O

V E

M B

E R

W H

N B

-- 1 -3

-0

S C

I M

IS

S

IO

N

C O

M M

A N

D U

N

IV

E R

S

IT

Y R

E G

IS

T

R A

R F

O R

C E

M O

D E

R N

IZ

A

T

IO

N A

N D

P R

O P

O N

E N

C Y

F Y

P

N

NORTH

KEY PLAN

A

C

D

EF

B

8'4' 16'0

SCALE: 1/8"=1'-0"

1/8" = 1'-0" A1

RCP - LEVEL 2 - AREA D

15. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED AND GWB CEILINGS SHALL BE CENTERED AND

EQUALLY SPACED ON EXTENTS UNLESS NOTED

OTHERWISE.

14. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED CEILINGS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

13. FOR ALL ACT CEILINGS THAT MEET AN EXPOSED

STRUCTURAL COLUMN END CEILING 1" FROM THE FACE OF

FLANGES WITH PERIMETER TRIM REFER TO E7/AI521.

12 ALIGN BULKHEADS WITH COLUMN FURRINGS OR EDGES,

UNLESS OTHERWISE NOTED.

11 PROVIDE ROLLER SHADES AT ALL EXTERIOR GLAZING,

EXCEPT AT STAIRS AND GLAZING BETWEEN GRIDS 6 AND 7

ON LEVELS 1 AND 2.

10. FOR ALL SUSPENDED CEILING ELEMENTS THAT DO NOT

TERMINATE AT A WALL PAINT EXPOSED CEILING ABOVE A

MINIMUM OF 3’-0” FROM EACH FACE OF PERIMETER TRIM

WITH PT-5 UNLESS NOTED OTHERWISE.

9. ALL SUSPENDED ACT CEIILNG ELEMENTS THAT DO NOT

TERMINATE AT A WALL REFER TO E8/AI521 PERIMETER TRIM

DETAILS.

8. REFERENCE TYPICAL CEILING DETAILS FOR CEILING

PERIMETER AND CONTROL JOINT DETAILS.

7. REFER TO MILLWORK DRAWINGS AND ELECTRICAL PLANS

FOR INTEGRATED LIGHTING.

6. UNLESS NOTED OTHERWISE, ALL DIMENSIONS TO LIGHT

FIXTURES ARE TO: -FIXTURE CENTERLINES: - COLUMN

CENTERLINES: - FACE OF GWB: - FACE OF MASONRY: - FACE

OF CONCRETE.

5. CENTER CEILNG LIGHTS, SPRINKLER HEADS, AND OTHER

CEILING MOUNTED DEVICES (RECESSED OR SURFACE

MOUNTING) IN CEILING TILE EXTENTS UNLESS NOTED

OTHERWISE.

4. LAY-IN CEILING PANELS SHALL NOT BE SMALLER THAN 6"

WIDE, TYPICAL.

3. CENTER CEILING TILES IN ROOM OR CENTER CEILING GRID

TO THE CENTER OF ROOM, UNLESS NOTED OTHERWISE.

2. REFER TO FINISH PLANS FOR CEILING TYPES AND FINISHES.

1. ALL CEILNG HEIGHTS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

REFLECTED CEILING PLAN

GENERAL NOTES

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/0

/2

FD G

ELEC

MECH

CAVE

256B

MALE

TOILET

STAIR #2

256A

FEMALE

TOILET

E

CLASSROOM

CLASSROOM

CLASSROOM

CLASSROOM

LAB

ELEV #1

C O

R R

ID

O

R

C O

R R

ID

O

R

MATCHLINE - SEE:AC102D

M A

T C

H

LI

N E

S

E E

:A C

2F

TELECOM

LAB

CORRIDOR

C O

R R

ID

O

R

C O

R R

ID

O

R

CORRIDOR

Sim

AI404

A4

ALIGN

A L

IG

N

ALIGN

A L

IG

N

4"

EQ EQ

ALIGN

E Q

E Q

E Q

E Q

EQ 6' - 0" EQ

EQ EQ

ALIGN

1'-0" 1'-0"

EQ

2' - 6"

EQ

256B

MALE

TOILET

256A

FEMALE

TOILET

ALIGN

ALIGN

4" 4"

REFLECTED CEILING PLAN LEGEND

LINEAR LIGHT FIXTURE

LINEAR PENDANT LIGHT FIXTURE

DOWN LIGHT FIXTURE

EXIT SIGN

SPEAKER

ACOUSTICAL CEILING TILE

SIZE VARIES REFER TO IN DRAWING SERIES

CEILING BAFFLES

SIZE VARIES REFER TO IN DRAWING SERIES

GYPSUM BOARD CEILING

EXPOSED

2 HOUR FIRE-RATED GYPSUM

BOARD SHAFT ENCLOSURE CEILING

FORMED METAL PANEL (FMP-1)

EXPANSION JOINT COVER (EJ-2)

TUBE LIGHT FIXTURE

ADD SUPPLEMENTAL BACKER ABOVE

CEILING. REFER TO SPECIFICATION 09 51 00.

KEYNOTES - RCP

PROVIDE BRACING AT ALL MONITOR LOCATIONS

ACCORDING TO OWNER SPECIFICATIONS.

1.

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

C A

T E

G O

R Y

C O

D E

C:\rvt\2019\10053876-A-MCA2-Central_HHEILE.rvt

1/7/2021 10:11:32 AM READY TO ADVERTISE (RTA)

AC102E

MCA2

A R

C H

IT

E

C T

U R

A L

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

L E

V E

L

A

R E

A E

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

A D

R A

K E

J K

R

IS

S O

F F

D H

O F

M A

N N

H E

Z Z

E D

D

IN

E

N O

V E

M B

E R

W H

N B

-- 1 -3

-0

S C

I M

IS

S

IO

N

C O

M M

A N

D U

N

IV

E R

S

IT

Y R

E G

IS

T

R A

R F

O R

C E

M O

D E

R N

IZ

A

T

IO

N A

N D

P R

O P

O N

E N

C Y

F Y

P

N

NORTH

KEY PLAN

A

C

D

EF

B

8'4' 16'0

SCALE: 1/8"=1'-0"

1/8" = 1'-0" A1

RCP - LEVEL 2 - AREA E

15. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED AND GWB CEILINGS SHALL BE CENTERED AND

EQUALLY SPACED ON EXTENTS UNLESS NOTED

OTHERWISE.

14. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED CEILINGS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

13. FOR ALL ACT CEILINGS THAT MEET AN EXPOSED

STRUCTURAL COLUMN END CEILING 1" FROM THE FACE OF

FLANGES WITH PERIMETER TRIM REFER TO E7/AI521.

12 ALIGN BULKHEADS WITH COLUMN FURRINGS OR EDGES,

UNLESS OTHERWISE NOTED.

11 PROVIDE ROLLER SHADES AT ALL EXTERIOR GLAZING,

EXCEPT AT STAIRS AND GLAZING BETWEEN GRIDS 6 AND 7

ON LEVELS 1 AND 2.

10. FOR ALL SUSPENDED CEILING ELEMENTS THAT DO NOT

TERMINATE AT A WALL PAINT EXPOSED CEILING ABOVE A

MINIMUM OF 3’-0” FROM EACH FACE OF PERIMETER TRIM

WITH PT-5 UNLESS NOTED OTHERWISE.

9. ALL SUSPENDED ACT CEIILNG ELEMENTS THAT DO NOT

TERMINATE AT A WALL REFER TO E8/AI521 PERIMETER TRIM

DETAILS.

8. REFERENCE TYPICAL CEILING DETAILS FOR CEILING

PERIMETER AND CONTROL JOINT DETAILS.

7. REFER TO MILLWORK DRAWINGS AND ELECTRICAL PLANS

FOR INTEGRATED LIGHTING.

6. UNLESS NOTED OTHERWISE, ALL DIMENSIONS TO LIGHT

FIXTURES ARE TO: -FIXTURE CENTERLINES: - COLUMN

CENTERLINES: - FACE OF GWB: - FACE OF MASONRY: - FACE

OF CONCRETE.

5. CENTER CEILNG LIGHTS, SPRINKLER HEADS, AND OTHER

CEILING MOUNTED DEVICES (RECESSED OR SURFACE

MOUNTING) IN CEILING TILE EXTENTS UNLESS NOTED

OTHERWISE.

4. LAY-IN CEILING PANELS SHALL NOT BE SMALLER THAN 6"

WIDE, TYPICAL.

3. CENTER CEILING TILES IN ROOM OR CENTER CEILING GRID

TO THE CENTER OF ROOM, UNLESS NOTED OTHERWISE.

2. REFER TO FINISH PLANS FOR CEILING TYPES AND FINISHES.

1. ALL CEILNG HEIGHTS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

REFLECTED CEILING PLAN

GENERAL NOTES

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/0

/2

A

B C D

LAB

STAIR #1

M A

T C

H

LI

N E

S

E E

:A C

E

LAB

LAB

LAB

INSTRUCTOR

CORRIDOR

C O

R R

ID

O

R

CORRIDOR

17.6

18.3

A.4

16.8

ALIGN

ALIGN

A L

IG

N

E Q

E Q

6' - 4" AFF

A L

IG

N

STAFF

BREAK

8' - 1 1/2" AFF

4"

END CEILING GRID

ON A FULL TILE.

REFLECTED CEILING PLAN LEGEND

LINEAR LIGHT FIXTURE

LINEAR PENDANT LIGHT FIXTURE

DOWN LIGHT FIXTURE

EXIT SIGN

SPEAKER

ACOUSTICAL CEILING TILE

SIZE VARIES REFER TO IN DRAWING SERIES

CEILING BAFFLES

SIZE VARIES REFER TO IN DRAWING SERIES

GYPSUM BOARD CEILING

EXPOSED

2 HOUR FIRE-RATED GYPSUM

BOARD SHAFT ENCLOSURE CEILING

FORMED METAL PANEL (FMP-1)

EXPANSION JOINT COVER (EJ-2)

TUBE LIGHT FIXTURE

ADD SUPPLEMENTAL BACKER ABOVE

CEILING. REFER TO SPECIFICATION 09 51 00.

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

C A

T E

G O

R Y

C O

D E

C:\rvt\2019\10053876-A-MCA2-Central_HHEILE.rvt

1/7/2021 10:11:39 AM READY TO ADVERTISE (RTA)

AC102F

MCA2

A R

C H

IT

E

C T

U R

A L

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

L E

V E

L

A

R E

A F

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

A D

R A

K E

J K

R

IS

S O

F F

D H

O F

M A

N N

H E

Z Z

E D

D

IN

E

N O

V E

M B

E R

W H

N B

-- 1 -3

-0

S C

I M

IS

S

IO

N

C O

M M

A N

D U

N

IV

E R

S

IT

Y R

E G

IS

T

R A

R F

O R

C E

M O

D E

R N

IZ

A

T

IO

N A

N D

P R

O P

O N

E N

C Y

F Y

P

N

NORTH

KEY PLAN

A

C

D

EF

B

8'4' 16'0

SCALE: 1/8"=1'-0"

1/8" = 1'-0" A1

RCP - LEVEL 2 - AREA F

15. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED AND GWB CEILINGS SHALL BE CENTERED AND

EQUALLY SPACED ON EXTENTS UNLESS NOTED

OTHERWISE.

14. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED CEILINGS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

13. FOR ALL ACT CEILINGS THAT MEET AN EXPOSED

STRUCTURAL COLUMN END CEILING 1" FROM THE FACE OF

FLANGES WITH PERIMETER TRIM REFER TO E7/AI521.

12 ALIGN BULKHEADS WITH COLUMN FURRINGS OR EDGES,

UNLESS OTHERWISE NOTED.

11 PROVIDE ROLLER SHADES AT ALL EXTERIOR GLAZING,

EXCEPT AT STAIRS AND GLAZING BETWEEN GRIDS 6 AND 7

ON LEVELS 1 AND 2.

10. FOR ALL SUSPENDED CEILING ELEMENTS THAT DO NOT

TERMINATE AT A WALL PAINT EXPOSED CEILING ABOVE A

MINIMUM OF 3’-0” FROM EACH FACE OF PERIMETER TRIM

WITH PT-5 UNLESS NOTED OTHERWISE.

9. ALL SUSPENDED ACT CEIILNG ELEMENTS THAT DO NOT

TERMINATE AT A WALL REFER TO E8/AI521 PERIMETER TRIM

DETAILS.

8. REFERENCE TYPICAL CEILING DETAILS FOR CEILING

PERIMETER AND CONTROL JOINT DETAILS.

7. REFER TO MILLWORK DRAWINGS AND ELECTRICAL PLANS

FOR INTEGRATED LIGHTING.

6. UNLESS NOTED OTHERWISE, ALL DIMENSIONS TO LIGHT

FIXTURES ARE TO: -FIXTURE CENTERLINES: - COLUMN

CENTERLINES: - FACE OF GWB: - FACE OF MASONRY: - FACE

OF CONCRETE.

5. CENTER CEILNG LIGHTS, SPRINKLER HEADS, AND OTHER

CEILING MOUNTED DEVICES (RECESSED OR SURFACE

MOUNTING) IN CEILING TILE EXTENTS UNLESS NOTED

OTHERWISE.

4. LAY-IN CEILING PANELS SHALL NOT BE SMALLER THAN 6"

WIDE, TYPICAL.

3. CENTER CEILING TILES IN ROOM OR CENTER CEILING GRID

TO THE CENTER OF ROOM, UNLESS NOTED OTHERWISE.

2. REFER TO FINISH PLANS FOR CEILING TYPES AND FINISHES.

1. ALL CEILNG HEIGHTS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

REFLECTED CEILING PLAN

GENERAL NOTES

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/0

/2

TSRQ

STAIR #5

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

M A

T C

H

LI

N E

S

E E

:A C

B

OFFICE

OFFICE

OPEN

OFFICE

CAVE

STORAGE

/2

8"

TYP

8 1/2"

/2

4"

TYP

1' - 0"

EQ EQ

ALIGN

A L

IG

N A

L

IG

N

ALIGN

E Q

E Q

VIF

V

IF

2' - 0"

V

IF

2' - 0"

ACT-3

ACT-4

ACT-6

2' - 0"

ACT-6

REFLECTED CEILING PLAN LEGEND

LINEAR LIGHT FIXTURE

LINEAR PENDANT LIGHT FIXTURE

DOWN LIGHT FIXTURE

EXIT SIGN

SPEAKER

ACOUSTICAL CEILING TILE

SIZE VARIES REFER TO IN DRAWING SERIES

CEILING BAFFLES

SIZE VARIES REFER TO IN DRAWING SERIES

GYPSUM BOARD CEILING

EXPOSED

2 HOUR FIRE-RATED GYPSUM

BOARD SHAFT ENCLOSURE CEILING

FORMED METAL PANEL (FMP-1)

EXPANSION JOINT COVER (EJ-2)

TUBE LIGHT FIXTURE

ADD SUPPLEMENTAL BACKER ABOVE

CEILING. REFER TO SPECIFICATION 09 51 00.

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

C A

T E

G O

R Y

C O

D E

C:\rvt\2019\10053876-A-MCA2-Central_HHEILE.rvt

1/7/2021 10:11:46 AM READY TO ADVERTISE (RTA)

AC103A

MCA2

A R

C H

IT

E

C T

U R

A L

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

L E

V E

L

A

R E

A A

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

A D

R A

K E

J K

R

IS

S O

F F

D H

O F

M A

N N

H E

Z Z

E D

D

IN

E

N O

V E

M B

E R

W H

N B

-- 1 -3

-0

S C

I M

IS

S

IO

N

C O

M M

A N

D U

N

IV

E R

S

IT

Y R

E G

IS

T

R A

R F

O R

C E

M O

D E

R N

IZ

A

T

IO

N A

N D

P R

O P

O N

E N

C Y

F Y

P

N

NORTH

KEY PLAN

A

C

D

EF

B

8'4' 16'0

SCALE: 1/8"=1'-0"

1/8" = 1'-0" A1

RCP - LEVEL 3 - AREA A

15. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED AND GWB CEILINGS SHALL BE CENTERED AND

EQUALLY SPACED ON EXTENTS UNLESS NOTED

OTHERWISE.

14. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED CEILINGS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

13. FOR ALL ACT CEILINGS THAT MEET AN EXPOSED

STRUCTURAL COLUMN END CEILING 1" FROM THE FACE OF

FLANGES WITH PERIMETER TRIM REFER TO E7/AI521.

12 ALIGN BULKHEADS WITH COLUMN FURRINGS OR EDGES,

UNLESS OTHERWISE NOTED.

11 PROVIDE ROLLER SHADES AT ALL EXTERIOR GLAZING,

EXCEPT AT STAIRS AND GLAZING BETWEEN GRIDS 6 AND 7

ON LEVELS 1 AND 2.

10. FOR ALL SUSPENDED CEILING ELEMENTS THAT DO NOT

TERMINATE AT A WALL PAINT EXPOSED CEILING ABOVE A

MINIMUM OF 3’-0” FROM EACH FACE OF PERIMETER TRIM

WITH PT-5 UNLESS NOTED OTHERWISE.

9. ALL SUSPENDED ACT CEIILNG ELEMENTS THAT DO NOT

TERMINATE AT A WALL REFER TO E8/AI521 PERIMETER TRIM

DETAILS.

8. REFERENCE TYPICAL CEILING DETAILS FOR CEILING

PERIMETER AND CONTROL JOINT DETAILS.

7. REFER TO MILLWORK DRAWINGS AND ELECTRICAL PLANS

FOR INTEGRATED LIGHTING.

6. UNLESS NOTED OTHERWISE, ALL DIMENSIONS TO LIGHT

FIXTURES ARE TO: -FIXTURE CENTERLINES: - COLUMN

CENTERLINES: - FACE OF GWB: - FACE OF MASONRY: - FACE

OF CONCRETE.

5. CENTER CEILNG LIGHTS, SPRINKLER HEADS, AND OTHER

CEILING MOUNTED DEVICES (RECESSED OR SURFACE

MOUNTING) IN CEILING TILE EXTENTS UNLESS NOTED

OTHERWISE.

4. LAY-IN CEILING PANELS SHALL NOT BE SMALLER THAN 6"

WIDE, TYPICAL.

3. CENTER CEILING TILES IN ROOM OR CENTER CEILING GRID

TO THE CENTER OF ROOM, UNLESS NOTED OTHERWISE.

2. REFER TO FINISH PLANS FOR CEILING TYPES AND FINISHES.

1. ALL CEILNG HEIGHTS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

REFLECTED CEILING PLAN

GENERAL NOTES

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

/0

/2

H K

M N P

STAIR #4

CONFERENCE

8-10 PN

STAFF

BREAK

OFFICE

OFFICE

OFFICE

OFFICE

J.4H.6

MATCHLINE - SEE:AC103C

M A

T C

H

LI

N E

S

E E

:A C

A

CAVE

ELEC

TELECOM

WORK/COPY

CAVE 372

LACTATION

CONFERENCE

20-30 PN

JAN.

CLO

MECH

OFFICE

OFFICE

CAVE

CORRIDOR

COLLAB

371A

CORRIDOR

OPEN

OFFICE

370A

ELEV #4

370B

ELEV #5

Sim

AI402

A5

COLLAB

CORRIDOR

ALIGN

/2

7"

TYP

1' - 0"

8 1/2"

T Y

P

/2

/2

T Y

P

TYP

1' - 0"

E Q

E Q

6' - 4" AFF

8' - 1 1/2" AFF

EQ EQ

EQ 6' - 4" EQEQ 6' - 4" EQ

EQ EQ

EQ EQ

E Q

E Q

ALIGN

EQ5' - 6"5' - 6"EQE

Q

E Q

EQ8' - 0"EQ

E Q

E Q

A L

IG

N

A L

IG

N

8 1/2"

A L

IG

N

A L

IG

N

8"

ALIGN

8"

A L

IG

N

4"

ALIGN

306B

FEMALE

TOILET

306A

MALE

TOILET

EQ 8' - 0" EQ

ALIGN 4

" ALIGN 8

CONTROL JOINT

ALIGN TO

ADJACENT WALL

E Q

E Q

EQ 7' - 4" EQ

VIF

V

IF

ACT-3

2' - 0"

ACT-4

2' - 0"

ACT-1

V

IF ACT-6

2' - 0"

ACT-7

REFLECTED CEILING PLAN LEGEND

LINEAR LIGHT FIXTURE

LINEAR PENDANT LIGHT FIXTURE

DOWN LIGHT FIXTURE

EXIT SIGN

SPEAKER

ACOUSTICAL CEILING TILE

SIZE VARIES REFER TO IN DRAWING SERIES

CEILING BAFFLES

SIZE VARIES REFER TO IN DRAWING SERIES

GYPSUM BOARD CEILING

EXPOSED

2 HOUR FIRE-RATED GYPSUM

BOARD SHAFT ENCLOSURE CEILING

FORMED METAL PANEL (FMP-1)

EXPANSION JOINT COVER (EJ-2)

TUBE LIGHT FIXTURE

ADD SUPPLEMENTAL BACKER ABOVE

CEILING. REFER TO SPECIFICATION 09 51 00.

KEYNOTES - RCP

PROVIDE BRACING AT ALL MONITOR LOCATIONS

ACCORDING TO OWNER SPECIFICATIONS.

1.

US Army Corps of Engineers ®

G

2 3 4 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

C A

T E

G O

R Y

C O

D E

C:\rvt\2019\10053876-A-MCA2-Central_HHEILE.rvt

1/7/2021 10:11:52 AM READY TO ADVERTISE (RTA)

AC103B

MCA2

A R

C H

IT

E

C T

U R

A L

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

L E

V E

L

A

R E

A B

F O

R T

G O

R D

O N

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

E S

T O

G L E

T H

O R

P E

A V

E N

U E

S A

V A

N N

A H

G

A

H D

R A

R L

IN

G T

O N

V

IR

G

IN

IA

A D

R A

K E

J K

R

IS

S O

F F

D H

O F

M A

N N

H E

Z Z

E D

D

IN

E

N O

V E

M B

E R

W H

N B

-- 1 -3

-0

S C

I M

IS

S

IO

N

C O

M M

A N

D U

N

IV

E R

S

IT

Y R

E G

IS

T

R A

R F

O R

C E

M O

D E

R N

IZ

A

T

IO

N A

N D

P R

O P

O N

E N

C Y

F Y

P

N

NORTH

KEY PLAN

A

C

D

EF

B

8'4' 16'0

SCALE: 1/8"=1'-0"

1/8" = 1'-0" A1

RCP - LEVEL 3 - AREA B

15. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED AND GWB CEILINGS SHALL BE CENTERED AND

EQUALLY SPACED ON EXTENTS UNLESS NOTED

OTHERWISE.

14. ALL MECHANICAL EQUIPMENT AND LIGHT FIXTURES IN

EXPOSED CEILINGS SHALL BE 10'-0" AFF UNLESS NOTED

OTHERWISE.

13. FOR ALL ACT CEILINGS THAT MEET AN EXPOSED

STRUCTURAL COLUMN END CEILING 1" FROM THE FACE OF

FLANGES WITH PERIMETER TRIM REFER TO E7/AI521.

12 ALIGN BULKHEADS WITH COLUMN FURRINGS OR EDGES,

UNLESS OTHERWISE NOTED.

11 PROVIDE ROLLER SHADES AT ALL EXTERIOR GLAZING,

EXCEPT AT STAIRS AND GLAZING BETWEEN GRIDS 6 AND 7

ON LEVELS 1 AND 2.

10. FOR ALL SUSPENDED CEILING ELEMENTS THAT DO NOT

TERMINATE AT A WALL PAINT EXPOSED CEILING ABOVE A

MINIMUM OF 3’-0” FROM EACH FACE OF PERIMETER TRIM

WITH PT-5 UNLESS NOTED OTHERWISE.

9. ALL SUSPENDED ACT CEIILNG ELEMENTS THAT DO NOT

TERMINATE AT A WALL REFER TO E8/AI521 PERIMETER TRIM

DETAILS.

8. REFERENCE TYPICAL CEILING DETAILS FOR CEILING

PERIMETER AND CONTROL JOINT DETAILS.

7. REFER TO MILLWORK DRAWINGS AND ELECTRICAL PLANS

FOR INTEGRATED LIGHTING.

6. UNLESS NOTED OTHERWISE, ALL DIMENSIONS TO LIGHT

FIXTURES ARE TO: -FIXTURE CENTERLINES: - COLUMN

CENTERLINES: - FACE OF GWB: - FACE OF MASONRY: - FACE

OF CONCRETE.

5. CENTER CEILNG LIGHTS, SPRINKLER HEADS, AND OTHER

CEILING MOUNTED DEVICES (RECESSED OR SURFACE

MOUNTING) IN CEILING TILE EXTENTS UNLESS NOTED

OTHERWISE.

4. LAY-IN CEILING PANELS SHALL NOT BE SMALLER THAN 6"

WIDE, TYPICAL.

3. CENTER CEILING TILES IN ROOM OR CENTER CEILING GRID

TO THE CENTER OF ROOM, UNLESS NOTED OTHERWISE.

2. REFER TO FINISH PLANS FOR CEILING TYPES AND FINISHES.

1. ALL CEILNG HEIGHTS SHALL BE…

This is the start of the file's text. The full file is on GovTribe.