W912HN-21-B-3002_VOL1D_AMD3_Rev1.pdf
PDF 938 KB Posted
- Solicitation number
- W912HN21B3002
About this file
This solicitation is for construction services for the PN88725 MCA2 University Registrar, Force Modernization & Proponency Facility project at Fort Gordon, Georgia. Bids are due by 1:00 PM ET on January 12, 2021 and will be opened at 2:00 PM ET on the same date. The solicitation was posted on December 2, 2020 and includes four specification files and ten drawing files. The construction work includes interior finishes for level 1 area D and is estimated at $5-10 million. The awarded firm will be required to complete interior construction and renovation in accordance with provided specifications and drawings by November 2022. The solicitation was issued by the Department of the Army Corps of Engineers Engineering District Savannah.
View the file
Other files
Show 40 more
Latest 50 of 62 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
H J K
MATCHLINE - SEE:IN101C
MATCHLINE - SEE:IN101E
LAB
RAF/CPT-1
RB-1
PT-1, PT-6, AWP-1
ACT-2
LAB
RAF/CPT-1
RB-1
PT-1, PT-6, AWP-1
ACT-2
LAB
RAF/CPT-1
RB-1
PT-1, PT-6, AWP-1
ACT-2
LAB
RAF/CPT-1
RB-1
PT-1, PT-6, AWP-1
ACT-2
STAIR
#3
CS-1
RB-2
PT-1, PT-9
EXP/PT-5
INSTRUCTOR
RAF/CPT-1
RB-1
PT-1, PT-3
ACT-2
P T
-6 P
T -6
P T
-6 P
T -6
EQF-3
W P
W P
AI404
E6
CAVE
RAF/CPT-1
RB-1
PT-1, AWP-3
ACT-2
ELEC
RAF/RT-1
RB-2
PT-1
EXP
TELECOM
RAF/SDT-1
RB-2
PT-1
EXP
STUDENT
COPY/PRINT
RAF/CPT-1
RB-1
PT-2, PT-7
EXP/PT-5
STUDENT
BREAK
CS-1
RB-2
PT-1, PT-7, EQF-3, WD-2
EXP/PT-11, GYP/PT-1, GYP/PT-7
CORRIDOR
CS-1
RB-3
PT-2, WP VARIES
ACT-3, EXP
AWP-3
STORAGE
RAF/RT-1
RB-2
PT-1
EXP
W P
W P
PT-7
WP
W D
-2
CORRIDOR
CS-1
RB-3
PT-2, PT-7, WP VARIES
ACT-3, GYP/PT-1, EXP
P T
-7
AWP-1 AWP-1
AWP-1 AWP-1
PT-7
PT-7
PT-7
P T
-7
A W
P -1
A W
P -1
A W
P -1
A W
P -1
PT-3
CORRIDOR
CS-1
RB-3
WP VARIES, PT-7
ACT-1, GYP/PT-1
GENERAL FINISH NOTES
1. ALL WALLS PAINTED PT-1 U.N.O.
2. BASE TO BE RB-1 U.N.O.
3. FLOORING MATERIAL TRANSITIONS SHALL OCCUR MID-
THRESHOLD AT DOORWAYS WHERE APPLICABLE.
4. PROVIDE TRANSITION STRIPS AND THRESHOLDS AS
REQUIRED.
5. MINIMIZE SEAMS PERPENDICULAR TO DOORWAYS AND
CASED OPENINGS.
6. BEGIN FLOOR TILE INSTALLATION FROM CENTER OF ROOM
OUT TO PERIMETER.
7. PAINT MECHANICAL DIFFUSERS / AIR GRILLES TO MATCH
MOUNTING SURFACE OR ADJACENT CEILING.
8. PAINT DOOR FRAMES PT-1 U.N.O.
9. REFER TO SHEET IN-601 FOR FINISH AND MATERIAL
INFORMATION.
10. REFER TO AI-441C & AI-441D SHEETS FOR EXTENTS OF GP-1
11. TERRAZZO SEAMS TO MATCH CONCRETE CONTROL JOINTS
12. PAINT ALL EXPOSED COLUMNS TO MATCH PT-3 U.N.O.
13. REFER TO RAISED FLOOR PLANS FOR EXTENT OF RAISED
ACCESS FLOOR. WHERE RAISED ACCESS FLOOR AND SLAB
MEET CONTINUE FLOOR FINISHES AS INDICATED ON FINISH
PLANS.
14. EXTENT OF FLOOR FINISHES TO CONTINUE UNDERNEATH ALL
CASEWORK, COUNTERTOPS AND EQUIPMENT, U.N.O.
15. FOR ALL SUSPENDED CEILING ELEMENTS THAT DO NOT
TERMINATE AT A WALL, PAINT EXPOSED CEILING ABOVE A
MINIMUM OF 3'-0" FROM EACH FACE OF PERIMETER TRIM
WITH PT-5 UNLESS OTHERWISE NOTED.
16. IN ALL BREAK ROOMS, CEILING ABOVE REFRIGERATORS TO
BE PT-7, CEILING ABOVE CASEWORK TO BE PT-1 U.N.O.
FINISH KEY
CEILING
WALL
BASE
FLOOR
ROOM NUMBER
CEILING FINISH
XX EXTENT OF WALL FINISH
FINISH CODE LEGEND
ACT ACOUSTIC CEILING TILE
AWP ACOUSTIC WALL PANEL
CPT CARPET TILE
CWT CERAMIC WALL TILE
CS CONCRETE SEALED
DF DECORATIVE FILM
EQF ENGINEERED QUARTZ
EJ EXPANSION JOINT
EXP EXPOSED CEILING
FCB FELT CEILING BAFFLE
FMP FORMED METAL PANEL
GP GLASS PANEL
GYP GYPSUM BOARD
MB METAL BASE
PBT PORCELAIN BASE TILE
PFT PORCELAIN FLOOR TILE
PLAM PLASTIC LAMINATE
PT PAINT
RAF RAISED ACCESS FLOOR WITH CONCRETE PAN
RB RUBBER BASE
RT RESILIENT TILE
SDT STATIC DISSIPATIVE TILE
SS SOLID SURFACE
TER TERRAZZO
WC WALL COVERING
WD WOOD PANEL
WP WALL PANEL
CPT-2
CPT-1 TER-1
CS-1 SDT-1
PFT-1
RT-1
WALL FINISH
BASE FINISH
FLOOR FINISH
ROOM NAME
* FINISHES IN ROOM TAG APPLY TO FULL ROOM,
UNLESS OTHERWISE NOTED WITH SYMBOL BELOW.
RAF EJ
US Army Corps of Engineers ®
G
2 3 4 6 7 8 9 10
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
C A
T E
G O
R Y
C O
D E
C:\rvt\2019\10053876-A-MCA2-Central_HHEILE.rvt
1/7/2021 10:13:06 AM READY TO ADVERTISE (RTA)
IN101D
MCA2
IN
T
E R
IO
R
D E
S
IG
N
F
IN
IS
H
P L A
N
L E
V E
L
A
R E
A D
F O
R T
G O
R D
O N
G
E O
R G
IA
S A
V A
N N
A H
D
IS
T R
IC
T
W
E S
T O
G L E
T H
O R
P E
A V
E N
U E
S A
V A
N N
A H
G
A
H D
R A
R L
IN
G T
O N
V
IR
G
IN
IA
E C
O O
P E
R
C N
O R
T H
C U
T T
D H
O F
M A
N N
H E
Z Z
E D
D
IN
E
N O
V E
M B
E R
W H
N B
-- 1 -3
-0
S C
I M
IS
S
IO
N
C O
M M
A N
D U
N
IV
E R
S
IT
Y R
E G
IS
T
R A
R F
O R
C E
M O
D E
R N
IZ
A
T
IO
N A
N D
P R
O P
O N
E N
C Y
F Y
P
N
NORTH
KEY PLAN
A
C
D
EF
B
8'4' 16'0
SCALE: 1/8"=1'-0"
1/8" = 1'-0" A1
INTERIOR FINISH PLAN LEVEL 1 - AREA D
R
E V
IS
E
D I N
A C
C O
R D
A N
C E
W
IT
H A
M E
N D
M E
N T
/0
/2
1/8/21
File details come from the government source that posted it. Updated .