VOL 7 OF 14_FACILITY G1_DRAWINGS_CDC_JUL 2026.pdf
PDF 3 MB Posted
- Attached to
- Apache Alert Mission Complex
- Solicitation number
- W912ER26RA016
About this file
This document is a set of architectural and engineering design drawings for the Kuwait Apache Alert Facilities Sunshade (Single Row) at Ali Al Salem Air Base, Kuwait, prepared for the Kuwait Ministry of Defense (KMOD) - Kuwait Air Force. The solicitation number is W912ER26RA016, with an issue date of July 2026. Volume 7 of 14 contains detailed design specifications for Facility G1, a single-row sunshade structure measuring approximately 30,400 millimeters in length and 7,940 millimeters in width, with a gross area of 256 square meters.
The design encompasses structural, architectural, and electrical systems. Structurally, the facility features six concrete column footings (CF1 and CF2 types), rectangular concrete columns (CC1), grade beams (CB1), and a 200-millimeter concrete slab on grade. The roof design uses a 2:12 slope with prefinished insulated metal roof assembly and includes lightning protection air terminals. Load criteria include a basic wind speed of 161 kilometers per hour (Exposure Category C), seismic design category C, and roof dead load of 0.5 kilopascals plus member self-weight. Electrical systems include ground floor lighting (6 fixtures controlled by dusk-dawn timer), power distribution via a stanchion-mounted panel (PPG1) with duplex receptacles, grounding with a 10-ohm or less earth resistance requirement, and lightning protection grounding. The drawings reference standard details, specifications, and comply with UFC 1-200-01, IBC 2021, ASCE 7-16, and AISC standards. Design responsibility for the metal building system is delegated to a qualified specialty structural engineer by the contractor.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US Army Corps of Engineers ®
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
VOLUME - FACILITY
VOLUME OF 14
FACILITY A - ALERT SHELTER
FACILITY C - LOGISTICS READINESS CENTER
FACILITY D - MAINTENANCE SUPPLY WAREHOUSE
FACILITY F - GUARD HOUSE
FACILITY H - PILOT READINESS FACILITY
FACILITY J - POL SHED
FACILITY K - SUBSTATION
FACILITY M - STORAGE SHADE
FACILITY N - WASH RACK SUNSHADE
FACILITY O - FIRE WATER PUMP HOUSE
GENERAL NOTES AND SITE DESIGN
INDEX OF VOLUMES
VOLUME
NUMBER
VOLUME TITLE
FACILITY G1 - SUNSHADES - SINGLE
FACILITY E - ALERT MAGAZINE
FACILITY STD - STANDARD DETAILS14
MIDDLE EAST DISTRICT
X:\REVIT PROJECTS\KUWAIT\2023\KU-509974-2 - APACHE ALERT MISSION FACILITIES\G1 - SUNSHADE - SINGLE ROW\KU-509974-2G1-DM-G-SUNS_RVT25.rvt
7/14/2026 3:02:37 PM
/1
/2
:0 :3
P
M
ALI AL SALEM AB, KUWAIT
KMOD – KUWAIT AIR FORCE
W912ER26RA016
JULY 2026
KU-509974-2
KUWAIT APACHE ALERT FACILITES
GI001
F A
C
IL
IT
Y
C O
V E
R S
H E
E T
A L I A
L S
A L E
M A
B K
U W
A
IT
C O
'B A
N N
O N
C O
'B A
N N
O N
E S
T
IL
L M
A N
J U
L Y
W E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
D R
A C
K M
A L E
S
K U
-5 -2
G -G
I0
S U
N S
H A
D E
S
IN
G
L E
R O
W
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
E
S
G1
C D
C
G1 - SUNSHADE - SINGLE ROW7
of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
X:\REVIT PROJECTS\KUWAIT\2023\KU-509974-2 - APACHE ALERT MISSION FACILITIES\G1 - SUNSHADE - SINGLE ROW\KU-509974-2G1-DM-G-SUNS_RVT25.rvt
7/14/2026 3:02:37 PM
/1
/2
:0 :3
P
M
GI011
IN
D
E X
O F
D R
A W
IN
G
S
A L I A
L S
A L E
M A
B K
U W
A
IT
C O
'B A
N N
O N
C O
'B A
N N
O N
E S
T
IL
L M
A N
J U
L Y
W E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
D R
A C
K M
A L E
S
K U
-5 -2
G -G
I0
S U
N S
H A
D E
S
IN
G
L E
R O
W
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
E
S
G1
C D
C
INDEX OF DRAWINGS
KU-509974-2 - FACILITY G1 - SUNSHADE
SHEET
ID
FILE NAME REV. NO.
AM/COP
NO.
SHEET TITLE
GENERAL
GI001 KU-509974-2G1-GI001 FACILITY COVER SHEET
GI011 KU-509974-2G1-GI011 INDEX OF DRAWINGS
STRUCTURAL
S-001 KU-509974-2-S-001 GENERAL STRUCTURAL NOTES
SB101 KU-509974-2-SB101 FOUNDATION PLAN
SB601 KU-509974-2-SB601 FOOTING SCHEDULES
SF101 KU-509974-2-SF101 FRAMING PLAN - GROUND FLOOR
SF102 KU-509974-2-SF102 FRAMING PLAN - ROOF
ARCHITECTURAL
A-001 KU-509974-2G1-A-001 GENERAL ARCHITECTURAL NOTES
AE101 KU-509974-2G1-AE101 FLOOR AND ROOF PLAN
AE102 KU-509974-2G1-AE102 REFLECTED CEILING PLAN
AE201 KU-509974-2G1-AE201 BUILDING ELEVATIONS
AE301 KU-509974-2G1-AE301 BUILDING SECTION
AE901 KU-509974-2G1-AE901 PERSPECTIVE VIEWS
ELECTRICAL
EL101 KU-509974-2G1-EL101 LIGHTING PLAN - GROUND FLOOR
EP101 KU-509974-2G1-EP101 POWER PLAN - GROUND FLOOR
EP501 KU-509974-2G1-EP501 POWER AND LIGHTING DETAILS
EP601 KU-509974-2G1-EP601 ONE-LINE DIAGRAM
EG101 KU-509974-2G1-EG101 GROUNDING PLAN - GROUND FLOOR
EG111 KU-509974-2G1-EG111 LIGHTNING PROTECTION PLAN - ROOF
C&C WALL WIND PRESSURE (kPa)
ZONE EFFECTIVE
AREA, M²
POSITIVE
PRESSURE
NEGATIVE
PRESSURE
NOTES
4 1.00 -1.10
0.76 -.88
0.70 -.80
-1.40
-1.05
-0.94
-0.80
0.83 -.93
0.93
9.30
18.58
46.45
0.93
46.45
1.00
0.76
0.70
0.839.30
18.58
C&C ROOF WIND PRESSURE (kPa)
ZONE POSITIVE
PRESSURE
NEGATIVE
PRESSURE
NOTES
1 0.77 -1.48
-1.66
-1.63
-1.59
-1.57
-2.10
-2.10
-1.73
EFFECTIVE
AREA, M²
-1.57
0.77
0.77
0.77
0.77
0.77
0.77
0.77
0.77
0.77
0.77
0.77
3'
3'
3'
3'
-2.82
-2.55
-2.19
-1.93
0.77
0.77
0.77
0.77
-1.48
-1.48
-1.48
2' -1.930.93 0.77
2' -1.909.30 0.77
2' -1.8618.58 0.77
2' -1.8446.45 0.77
0.93
9.30
18.58
46.45
0.93
9.30
18.58
46.45
0.93
9.30
18.58
46.45
0.93
9.30
18.58
46.45
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
/8
/2
:3 :3
P
M
S-001
G E
N E
R A
L S
T R
U C
T U
R A
L N
O T
E S
A L I A
L S
A L E
M A
B K
U W
A
IT
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P H
IL
A
D E
L P
H
IA
D
IS
T R
IC
T
A
R C
H S
T R
E E
T P
H
IL
A D
E L P
H
IA
L R
Y A
N
L R
Y A
N
S A
L S
A B
B A
G H
J U
L Y
W
E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
C C
H A
S T
E N K
U -5
-2
-S -0
S U
N S
H A
D E
S
IN
G
L E
R O
W
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
E
S
G1
C D
C
GENERAL NOTES
1. REFERENCE STANDARDS:
UFC 1-200-01 DOD BUILDING CODE WITH CHANGE 3, 26 FEB 2024
UFC 3-301-01 STRUCTURAL ENGINEERING, CHANGE 1, 2 OCTOBER 2023
UFC 3-320-06A CONCRETE FLOOR SLABS ON GRADE SUBJECTED TO HEAVY LOADS, 1 MARCH 2005
IBC 2021 INTERNATIONAL BUILDING CODE, 2021
ASCE 7-16 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
AISC-15TH AMERICAN INSTITUTE OF STEEL CONSTRUCTION - 15TH EDITION
AISC 341-16 SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS
ACI 318-19 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, 2019
TMS 402/602-16 BUILDING CODE REQUIREMENTS AND SPECIFICATION FOR MASONRY STRUCTURES
AWS D1.1 STRUCTURAL WELDING CODE - STEEL, 2015
AWS D1.8 STRUCTURAL WELDING CODE - SEISMIC SUPPLEMENT, 2016
2. DESIGN LOAD CRITERIA:
RISK CATEGORY : II
ROOF DEAD LOAD: 0.5kPa + MEMBER SELF-WEIGHT ROOF LIVE LOAD: 1.0 kPa MINIMUM
SNOW LOAD: N/A
SEISMIC LOAD:
SITE CLASS: C
IMPORTANT FACTOR, Ie: 1.0
SPECTRAL RESPONSE ACCELERATIONS:
SHORT PERIOD, Ss: 0.410g ONE SECOND PERIOD, S1: 0.110g
DESIGN SPECTRAL RESPONSE ACCELERATIONS:
SHORT PERIOD, SDS: 0.355g ONE SECOND PERIOD, SD1: 0.110g
SEISMIC DESIGN CATEGORY: C
SEISMIC ANALYTICAL PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE
LATERAL FORCE RESISTING SYSTEM : STEEL ORDINARY CANTILEVER COLUMN SYSTEM
RESPONSE MODIFICATION FACTOR, R: 1.25
SYSTEM OVERSTRENGTH FACTOR: 1.25
DEFLECTION AMPLIFICATION FACTOR, Cd: 1.25 SEISMIC RESPONSE COEFFICIENT, Cs: 0.284
DESIGN BASESHEAR, V: 0.284W
WIND LOAD:
BASIC WIND SPEED, V: 161 KPH
EXPOSURE CATEGORY: C
IMPORTANT FACTOR, Iw: 1.00 INTERNAL PRESSURE COEFFICIENT, GCpi: +/-0.0 TOPOGRAPHIC FACTOR, Kzt: 1.0 DIRECTIONALITY FACTOR, Kd: 0.85
FOUNDATION DESIGN CRITERIA
FOUNDATION DESIGN IS BASED UPON THE FOLLOWING ASSUMED SOIL PARAMETERS:
NET ALLOWABLE SOIL BEARING PRESSURE:
A. SPREAD FOOTINGS: 168kPa B. CONTINUOUS FOOTINGS: 153kPa
LATERAL EARTH PRESSURE PARAMETERS:
A. SOIL DENSITY (MOIST): 19.6kN/m³ B. COEFFICIENT OF ACTIVE PRESSURE (Ka): 0.31 C. COEFFICIENT OF AT-REST PRESSURE (Ko): 0.47 D. COEFFICIENT OF PASSIVE EARTH PRESSURE (Kp): 3.25
E. ANGLE OF INTERNAL FRICTION (Φ): 32°
F. COEFFICIENT OF FRICTION (μ): 0.40 G. MODULUS OF SUB-GRADE REACTION (Ks) FOR SOG: 54MN/m3
DELEGATED NOTES
1. THE DESIGN RESPONSIBILITY FOR THE FOLLOWING ENGINEERED SYSTEMS AND COMPONENTS IS DELEGATED TO A QUALIFIED SPECIALTY STRUCTURAL ENGINEER BY THE CONTRACTOR. THESE SYSTEMS AND COMPONENTS INCLUDE, BUT ARE NOT LIMITED TO:
A. METAL BUILDING SYSTEM.
NOTES:
1. ALL EXTERIOR WALLS, WINDOWS, DOORS, MECH. LOUVERS, ROOFING COMPONENTS, AND ALL OTHER ASSEMBLIES OR OPENINGS WITHIN THE
BUILDING ENVELOPE SHALL BE DESIGNED FOR THE C&C DESIGN WIND PRESSURES AS SHOWN BY ZONE.
2. LOCATION OF ZONES IS PROVIDED PER ASCE7-16, FIG. 30.3-1 & 30.3-2B
3. DISTANCE (a) = 1200mm.
4. THE CONTRACTOR SHALL USE COMPONENT AND CLADDING WIND PRESSURE TO DESIGN ALL ELEMENTS ATTACHED TO THE BUILDING.
1 2 3 4 5 6
B
EL.-1500
CF2
EL.-1500
CF2
EL.-1500
CF2
EL.-1500
CF2
EL.-1500
CF1
EL.-1500
CF1
CC1 CC1 CC1 CC1 CC1 CC1
A
6200 6000 6000 6000 6200
30400
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
GENERAL NOTES
/8
/2
:3 :3
P
M
SB101
F O
U N
D A
T
IO
N P
L A
N
A L I A
L S
A L E
M A
B K
U W
A
IT
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P H
IL
A
D E
L P
H
IA
D
IS
T R
IC
T
A
R C
H S
T R
E E
T P
H
IL
A D
E L P
H
IA
L R
Y A
N
L R
Y A
N
S A
L S
A B
B A
G H
J U
L Y
W
E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
C C
H A
S T
E N K
U -5
-2
-S B
S U
N S
H A
D E
S
IN
G
L E
R O
W
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
E
S
G1
C D
C
0 1051 2 3 4
1:100
1. ELEVATION 0.00 EQUATES TO FINISHED FLOOR ELEVATION
ALL ELEVATIONS ARE REFERENCED FROM ELEVATION 0.00.
2. SEE SHEET SB601 FOR FOUNDATION AND PIER SCHEDULES.
3. REFER TO STANDARD DETAIL - SS508, SS511 AND SS601 FOR
CONCRETE AND REINFORCEMENT PROPERTIES AND
SCHEDULES.
1 : 1001
FOUNDATION PLAN
COLUMN REACTIONS
B-1 B-2 B-3
LOAD CATEGORY X Y Z MX MZ X Y Z MX MZ X Y Z MX MZ
Dead Load 2.32kN 35.12kN 0.33kN 0.5kN-m -166.8kN-m -1.22kN 50.60kN -0.04kN 0kN-m -162kN-m -1.11kN 50.08kN 0.00kN 0.0kN-m -162.5kN-m
Live Load 4.31kN 25.16kN 0.02kN 0.0kN-m -169.1kN-m -2.26kN 49.17kN 0.01kN 0kN-m -161kN-m -2.05kN 48.49kN 0.00kN 0.0kN-m -161.2kN-m
Wind Z+ 2.02kN 2.38kN -1.51kN -4.4kN-m -27.9kN-m 0.58kN 6.52kN -2.20kN -5kN-m -24kN-m 0.03kN 6.29kN -2.14kN -5.3kN-m -22.0kN-m
Wind Z- -0.92kN 4.15kN 1.54kN 4.5kN-m -15.8kN-m -1.15kN 6.27kN 2.20kN 5kN-m -17kN-m -0.55kN 6.32kN 2.14kN 5.3kN-m -19.6kN-m
Wind X+ 0.00kN 0.00kN 0.00kN 0.0kN-m 0.0kN-m 0.00kN 0.00kN 0.00kN 0kN-m 0kN-m 0.00kN 0.00kN 0.00kN 0.0kN-m 0.0kN-m
Wind X- -5.30kN -35.80kN -0.02kN 0.0kN-m 211.2kN-m 1.58kN -61.94kN -0.01kN 0kN-m 202kN-m -0.81kN -52.96kN 0.01kN 0.0kN-m 205.4kN-m
EQ Z+ 2.53kN -2.04kN -3.55kN -9.9kN-m -10.4kN-m 1.46kN 0.18kN -4.71kN -12kN-m -6kN-m 0.48kN -0.03kN -4.61kN -11.4kN-m -2.0kN-m
EQ Z- -2.49kN 2.04kN 3.55kN 9.9kN-m 10.4kN-m -1.48kN -0.18kN 4.71kN 12kN-m 6kN-m -0.50kN 0.03kN 4.61kN 11.4kN-m 2.1kN-m
EQ X+ -12.01kN 0.00kN 0.00kN 0.0kN-m 58.1kN-m -12.01kN 0.00kN 0.00kN 0kN-m 58kN-m -12.01kN 0.00kN 0.00kN 0.0kN-m 58.1kN-m
EQ X- 12.01kN 0.00kN 0.00kN 0.0kN-m -58.0kN-m 12.01kN 0.00kN 0.00kN 0kN-m -58kN-m 12.01kN 0.00kN 0.00kN 0.0kN-m -58.0kN-m
EQ Z+ ECC 2.39kN -2.04kN -3.55kN -9.9kN-m -9.9kN-m 1.38kN 0.18kN -4.71kN -12kN-m -6kN-m 0.45kN -0.03kN -4.61kN -11.4kN-m -1.9kN-m
EQ Z- ECC 2.67kN -2.04kN -3.55kN -9.9kN-m -11.0kN-m 1.54kN 0.18kN -4.71kN -12kN-m -6kN-m 0.51kN -0.03kN -4.61kN -11.4kN-m -2.1kN-m
EQ X+ ECC -9.42kN 0.00kN 0.00kN 0.0kN-m 45.6kN-m -10.47kN 0.00kN 0.00kN 0kN-m 51kN-m -11.49kN 0.00kN 0.00kN 0.0kN-m 55.7kN-m
EQ X- ECC -14.60kN 0.00kN 0.00kN 0.0kN-m 70.7kN-m -13.54kN 0.00kN 0.00kN 0kN-m 66kN-m -12.52kN 0.00kN 0.00kN 0.0kN-m 60.6kN-m
EQ Z+ ECC (-) -2.35kN 2.04kN 3.55kN 9.9kN-m 9.8kN-m -1.40kN -0.18kN 4.71kN 12kN-m 6kN-m -0.47kN 0.03kN 4.61kN 11.4kN-m 2.0kN-m
EQ Z- ECC (-) -2.62kN 2.04kN 3.55kN 9.9kN-m 11.0kN-m -1.56kN -0.18kN 4.71kN 12kN-m 6kN-m -0.53kN 0.03kN 4.61kN 11.4kN-m 2.2kN-m
EQ X+ ECC (-) 9.42kN 0.00kN 0.00kN 0.0kN-m -45.5kN-m 10.47kN 0.00kN 0.00kN 0kN-m -51kN-m 11.50kN 0.00kN 0.00kN 0.0kN-m -55.5kN-m
EQ X- ECC (-) 14.60kN 0.00kN 0.00kN 0.0kN-m -70.4kN-m 13.54kN 0.00kN 0.00kN 0kN-m -65kN-m 12.52kN 0.00kN 0.00kN 0.0kN-m -60.4kN-m
B-4 B-5 B-6
LOAD CATEGORY X Y Z MX MZ X Y Z MX MZ X Y Z MX MZ
Dead Load -1.11kN 50.08kN 0.00kN 0.0kN-m -162.5kN-m -1.22kN 50.60kN 0.04kN 0.1kN-m -162.4kN-m -1.11kN 50.08kN 0.00kN 0.0kN-m -162.5kN-m
Live Load -2.05kN 48.49kN 0.00kN 0.0kN-m -161.2kN-m -2.26kN 49.17kN -0.01kN 0.0kN-m -161.0kN-m -2.05kN 48.49kN 0.00kN 0.0kN-m -161.2kN-m
Wind Z+ -0.55kN 6.32kN -2.14kN -5.3kN-m -19.6kN-m -1.15kN 6.27kN -2.20kN -5.4kN-m -17.2kN-m 0.03kN 6.29kN -2.14kN -5.3kN-m -22.0kN-m
Wind Z- 0.03kN 6.29kN 2.14kN 5.3kN-m -22.0kN-m 0.58kN 6.52kN 2.20kN 5.4kN-m -24.4kN-m -0.55kN 6.32kN 2.14kN 5.3kN-m -19.6kN-m
Wind X+ 0.00kN 0.00kN 0.00kN 0.0kN-m 0.0kN-m 0.00kN 0.00kN 0.00kN 0.0kN-m 0.0kN-m 0.00kN 0.00kN 0.00kN 0.0kN-m 0.0kN-m
Wind X- -0.81kN -52.96kN -0.01kN 0.0kN-m 205.4kN-m 1.58kN -61.94kN 0.01kN 0.0kN-m 202.3kN-m -0.81kN -52.96kN 0.01kN 0.0kN-m 205.4kN-m
EQ Z+ -0.50kN 0.03kN -4.61kN -11.4kN-m 2.1kN-m -1.48kN -0.18kN -4.71kN -11.5kN-m 6.2kN-m 0.48kN -0.03kN -4.61kN -11.4kN-m -2.0kN-m
EQ Z- 0.48kN -0.03kN 4.61kN 11.4kN-m -2.0kN-m 1.46kN 0.18kN 4.71kN 11.5kN-m -6.1kN-m -0.50kN 0.03kN 4.61kN 11.4kN-m 2.1kN-m
EQ X+ -12.01kN 0.00kN 0.00kN 0.0kN-m 58.1kN-m -12.01kN 0.00kN 0.00kN 0.0kN-m 58.1kN-m -12.01kN 0.00kN 0.00kN 0.0kN-m 58.1kN-m
EQ X- 12.01kN 0.00kN 0.00kN 0.0kN-m -58.0kN-m 12.01kN 0.00kN 0.00kN 0.0kN-m -58.0kN-m 12.01kN 0.00kN 0.00kN 0.0kN-m -58.0kN-m
EQ Z+ ECC -0.47kN 0.03kN -4.61kN -11.4kN-m 2.0kN-m -1.40kN -0.18kN -4.71kN -11.5kN-m 5.8kN-m 0.45kN -0.03kN -4.61kN -11.4kN-m -1.9kN-m
EQ Z- ECC -0.53kN 0.03kN -4.61kN -11.4kN-m 2.2kN-m -1.56kN -0.18kN -4.71kN -11.5kN-m 6.5kN-m 0.51kN -0.03kN -4.61kN -11.4kN-m -2.1kN-m
EQ X+ ECC -12.52kN 0.00kN 0.00kN 0.0kN-m 60.6kN-m -13.54kN 0.00kN 0.00kN 0.0kN-m 65.6kN-m -11.49kN 0.00kN 0.00kN 0.0kN-m 55.7kN-m
EQ X- ECC -11.49kN 0.00kN 0.00kN 0.0kN-m 55.7kN-m -10.47kN 0.00kN 0.00kN 0.0kN-m 50.7kN-m -12.52kN 0.00kN 0.00kN 0.0kN-m 60.6kN-m
EQ Z+ ECC (-) 0.45kN -0.03kN 4.61kN 11.4kN-m -1.9kN-m 1.38kN 0.18kN 4.71kN 11.5kN-m -5.8kN-m -0.47kN 0.03kN 4.61kN 11.4kN-m 2.0kN-m
EQ Z- ECC (-) 0.51kN -0.03kN 4.61kN 11.4kN-m -2.1kN-m 1.54kN 0.18kN 4.71kN 11.5kN-m -6.5kN-m -0.53kN 0.03kN 4.61kN 11.4kN-m 2.2kN-m
EQ X+ ECC (-) 12.52kN 0.00kN 0.00kN 0.0kN-m -60.4kN-m 13.54kN 0.00kN 0.00kN 0.0kN-m -65.3kN-m 11.50kN 0.00kN 0.00kN 0.0kN-m -55.5kN-m
EQ X- ECC (-) 11.50kN 0.00kN 0.00kN 0.0kN-m -55.5kN-m 10.47kN 0.00kN 0.00kN 0.0kN-m -50.6kN-m 12.52kN 0.00kN 0.00kN 0.0kN-m -60.4kN-m
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
GENERAL NOTES
/8
/2
:3 :3
P
M
SB601
F O
O T
IN
G
S C
H E
D U
L E
S
A L I A
L S
A L E
M A
B K
U W
A
IT
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P H
IL
A
D E
L P
H
IA
D
IS
T R
IC
T
A
R C
H S
T R
E E
T P
H
IL
A D
E L P
H
IA
L R
Y A
N
L R
Y A
N
S A
L S
A B
B A
G H
J U
L Y
W
E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
C C
H A
S T
E N K
U -5
-2
-S B
S U
N S
H A
D E
S
IN
G
L E
R O
W
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
E
S
G1
C D
C
COLUMN FOOTING SCHEDULE
MARK
DIMENSIONS REINFORCEMENT
REMARKSWidth Length Foundation Thickness
LONGITUDINAL TRANSVERSE
QTY SIZE QTY SIZE
CF1 1750 4850 400 13 D16 23 D16
CF2 1750 4250 400 13 D16 23 D16
GRADE BEAM SCHEDULE
MARK
DIMENSIONS REINFORCEMENT
REMARKSWIDTH DEPTH
TOP BOTTOM
STIRRUPSQUANTITY SIZE QUANTITY SIZE
CB1 625 625 4 D19 4 D19 D13@200
RECTANGULAR CONCRETE COLUMN SCHEDULE
Type Mark
DIMENSIONS REINFORCEMENT
REMARKS
COLUMN
DEPTH
COLUMN
WIDTH
LONGITUDINAL TIES
QUANTITY SIZE SIZE SPACING
CC1 625 625 16 D19 D13 300 PROVIDE ADDITIONAL TIES @ 75MM O/C IN TOP 300MM OF COLUMN
1. COLUMN REACTIONS SHOWN ARE UNFACTORED AND BASED
ON PRELIMINARY DESIGN OF METAL BUILDING SYSTEMS
(MBS). CONTRACTOR SHALL OBTAIN COLUMN REACTION
INFORMATION FROM METAL BUILDING SYSTEM
MANUFACTURER AND VERIFY THAT THE FOUNDATIONS
SHOWN ARE ADEQUATE TO SUPPORT THOSE REACTIONS.
CONTRACTOR SHALL INCREASE FOUNDATION DIMENSIONS
AND REINFORCING IF NEEDED, SUBJECT TO REVIEW AND
APPROVAL OF CONTRACTING OFFICER'S
REPRESENTATIVE.
2. TABULATED SEISMIC LOADS DO NOT ACCOUNT FOR CODE
REQUIRED REDUNDANCY FACTORS OR VERTICAL SEISMIC
LOADS. FOUNDATIONS ARE DESIGNED BASED ON STRENGTH
DESIGN AND ALLOWABLE STRESS DESIGN LOAD
COMBINATIONS THAT CONSIDER REDUNDACY FACTORS AND
VERTICAL SEISMIC LOADS IN ACCORDANCE WITH ASCE 7-16.
ASSUMED METAL BUILDING COLUMN BASE
A
200MM CONCRETE SLAB ON GRADE
W/ D13 AT 200 O/C EW T&B
CB1
-200
CB1
-200
CB1
-200
CB1
-200
CB1
-200
6200 6000 6000 6000 6200
30400
315315
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
GENERAL NOTES
/8
/2
:3 :3
P
M
SF101
F R
A M
IN
G
P L
A N
G
R O
U N
D F
L O
O R
A L I A
L S
A L E
M A
B K
U W
A
IT
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P H
IL
A
D E
L P
H
IA
D
IS
T R
IC
T
A
R C
H S
T R
E E
T P
H
IL
A D
E L P
H
IA
L R
Y A
N
L R
Y A
N
S A
L S
A B
B A
G H
J U
L Y
W
E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
C C
H A
S T
E N K
U -5
-2
-S F
S U
N S
H A
D E
S
IN
G
L E
R O
W
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
E
S
G1
C D
C
1 : 1001
FLOOR PLAN - GROUND FLOOR
1. ELEVATION 0.00 EQUATES TO FINISHED FLOOR ELEVATION
ALL ELEVATIONS ARE REFERENCED FROM ELEVATION 0.00.
2. 200MM CONCRETE SLAB ON GRADE W/ D13 AT 200 O/C EW
T&B
3. REFER TO STANDARD DETAIL-SHEET SS502/DETAIL 4 FOR
THE SLAB ON GRADE JOINT FOR WHEELED TRAFFIC.
4. REFER TO STANDARD DETAIL-SHEET SS502/DETAIL 7 FOR
SLAB ON GRADE ISOLATED JOINT AT CONCRETE COLUMNS.
5. REFER TO STANDARD DETAIL-SHEET SS503/DETAIL 4 FOR
THICKENED SLAB EDGE.
6. SEE CIVIL FOR SIZE, LOCATIONS AND INSTALLATION DETAIL
OF WHEEL STOPS.
0 1051 2 3 4
1:100
ROOF FRAMING BY
MBS SUPPLIER
A
6200 6000 6000 6000 6200
30400
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
GENERAL NOTES
/8
/2
:3 :3
P
M
SF102
F R
A M
IN
G
P L
A N
R
O O
F
A L I A
L S
A L E
M A
B K
U W
A
IT
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P H
IL
A
D E
L P
H
IA
D
IS
T R
IC
T
A
R C
H S
T R
E E
T P
H
IL
A D
E L P
H
IA
L R
Y A
N
L R
Y A
N
S A
L S
A B
B A
G H
J U
L Y
W
E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
C C
H A
S T
E N K
U -5
-2
-S F
S U
N S
H A
D E
S
IN
G
L E
R O
W
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
E
S
G1
C D
C
1 : 1001
FRAMING PLAN - ROOF
1. ROOF FRAMING SHALL BE DESIGNED BY MBS SUPPLIER TO
SUPPORT ALL LOADS LISTED IN THE GENERAL NOTES.
REFER TO ARCH FOR ROOFING MATERIALS.
2. REFER TO ARCH FOR TOP OF ROOF ELEVATIONS.
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
GENERAL SHEET NOTES
X:\REVIT PROJECTS\KUWAIT\2023\KU-509974-2 - APACHE ALERT MISSION FACILITIES\G1 - SUNSHADE - SINGLE ROW\KU-509974-2G1-DM-A-SUNS_RVT25.rvt
7/14/2026 7:56:35 AM
/1
/2
:5 :3
A
M
A-001
G E
N E
R A
L A
R C
H
IT
E C
T U
R A
L N
O T
E S
A L I A
L S
A L E
M A
B K
U W
A
IT
D .G
U R
A K
D G
U R
A K
C .G
O R
D O
N
J U
L Y
W E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
A F
R E
E M
A N K
U -5
-2
G -A
-0
S U
N S
H A
D E
S
IN
G
L E
R O
W
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
IE
S
G1
C D
C
1. CONSTRUCTION SHALL BE AS INDICATED IN DRAWINGS IN TANDEM WITH
CONTRACT SPECIFICATIONS
2. CANOPY PLANS AND ELEVATIONS PROVIDED FOR GENERAL PURPOSES ONLY.
THE FULL CANOPY DESIGN AND INSTALLATION SHALL BE PROVIDED BY
CANOPY MANUFACTURER.
3. REFER TO CIVIL DRAWINGS FOR LOCATION AND TRUE NORTH, GRADE
SLOPES, AND STRIPING MARKS.
A ------------------------------
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL SYSTEM
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH DISABILITIES
ACT
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE
APC ACOUSTICAL PANEL CEILING
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVG AVERAGE
AW ARCHITECTURAL WOODWORK
AWT ACOUSTICAL WALL TREATMENT
B -------------------------------
B LABEL CLASS B DOOR
BALC BALCONY
BB BASEBOARD
BC BOOKCASE
BD BOARD
BDRY BOUNDARY
BFF BELOW FINISH FLOOR
BHMA BUILDER'S HARDWARE
MANUFACTURER'S ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BN BULLNOSE
BO BOTTOM OF
BOS BOTTOM OF STEEL
BOT BOTTOM
BP BUILDING PAPER
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C -------------------------------
C CONC CAST CONCRETE
C LABEL CLASS C DOOR
CAB CABINET
CATW CATWALK
CAV CAVITY
CBB CEMENTITIOUS (BACKER) BOARD
CD CONSTRUCTION DOCUMENTS
CDW CHILLED DRINKING WATER
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR
FURNISHED/CONTRACTOR INSTALLED
CFE CONTRACTOR FURNISHED
EQUIPMENT
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR COLOR
CLRM CLASSROOM
CMU CONCRETE MASONRY UNIT
CNDS CONDENSATE
CDR CARD READER
CO CLEANOUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
CONT CONTINUE
COORD COORDINATE
COR CONTRACTOR OF RECORD
CORR CORRIDOR
CP CONCRETE PIPE
CPT CARPET
CR CONTROL ROOM
CS CAST STONE
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CU FT CUBIC FEET
CW CASEMENT WINDOW
D -------------------------------
D DEPTH
D LABEL CLASS D DOOR
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DOR DESIGNER OF RECORD
DR DOOR
DS DOWNSPOUT
E ------------------------------
E LABEL CLASS E DOOR
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION AND FINISH
SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEV ELEVATOR
ENTR ENTRANCE
EPS EXPANDED POLYSTYRENE BOARD
(INSULATION)
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXP EXPOSED
EXT EXTERIOR
EXT EXTINGUISHER
EXT GR EXTERIOR GRADE
F -------------------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FAS BD FASCIA BOARD
FC BRK FACE BRICK
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FED FEDERAL
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF INSUL FOIL BACKED INSULATION
FGL FIBERGLASS
FH FIRE HOSE
FHP FULL HEIGHT PARTITION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLASH FLASHING
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FM FACTORY MUTUAL
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FRG FIBER REINFORCED GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED
PLASTIC
FRTW FIRE RETARDANT TREATED WOOD
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET
FTG FOOTING
FWC FABRIC WALLCOVERING
G -------------------------------
G NATURAL GAS
GALV GALVANIZED
GB GRAB BAR
GFCI GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
GFGI GOVERNMENT INSTALLED
GOVERNMENT INSTALLED
GFRG GLASS-FIBER-REINFORCED
GYPSUM
GLZ GLAZING
GR FL GROUND FLOOR
GUT GUTTER
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H -------------------------------
HB HOSE BIBB
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE
AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HT HEIGHT
HYDR HYDRAULIC
I -------------------------------
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J -------------------------------
JAN JANITOR
K -------------------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L -------------------------------
LAM LAMINATE
LAV LAVATORY
LBR LUMBER
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LIB LIBRARY
LIN LINEAR
LKR LOCKER
LOC LOCATION
LT LIGHT
LVDR LOUVER DOOR
LVR LOUVER
M -------------------------------
MACH RM MACHINE ROOM
MATL MATERIAL
MAX MAXIMUM
MC MOISTURE CONTENT
MD METAL DECK
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MEMB MEMBRANE
MF MILL FINISH
MFR MANUFACTURER
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MO MASONRY OPENING
MOD MODIFY
MB MOISTURE BARRIER
MTG MOUNTING
MTL METAL
MVBL MOVABLE
MWP MEMBRANE WATERPROOFING
N -------------------------------
N NORTH
NA NOT APPLICABLE
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NP NO PAINT
NRC NOISE REDUCTION
O -------------------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPQ OPAQUE
OWSJ OPEN WEB STEEL JOIST
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P -------------------------------
PA PUBLIC ADDRESS
PAR PARAPET
PAT PATTERN
PB PULL BOX
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PIL PILASTER
PL PROPERTY LINE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLG PILING
PLYWD PLYWOOD
PNL PANEL
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PRKG PARKING
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INC
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER AND
RECEPTACLE
PTN PARTITION
PWR POWER
Q -------------------------------
QT QUARRY TILE
QTY QUANTITY
R -------------------------------
RAF RAISED ACCESS FLOORING
RB RESILIENT BASE
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDG INS RIGID INSULATION, SOLID
REC RECESSED
REC RM RECREATION ROOM
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RL ROOF LEADER
RLG RAILING
RM ROOM
RO ROUGH OPENING
RSD ROLLING STEEL DOOR
RV ROOF VENT
RVL REVEAL
S -------------------------------
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGL SINGLE
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SKLT SKYLIGHT
SLNT SEALANT
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SST STAINLESS STEEL
ST STAIRS
STD STANDARD
STL STEEL
STL JST STEEL JOIST
STL RF DK STEEL ROOF DECK
STOR STORAGE
STR STRINGERS
STRB/HRN STROBE/HORN
SUB FL SUBFLOOR
SV SHEET VINYL
SW SIDEWALK
T -------------------------------
T TREAD
T/S TUB/SHOWER
TC TERRA COTTA
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TFF TOP OF FINISH FLOOR
THK THICKNESS
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TO TOP OF
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TRANS TRANSOM
TRTD TREATED
TV TELEVISION
U -------------------------------
UBC UNIFORM BUILDING CODE
UG UNDERGROUND
UNO UNLESS OTHERWISE NOTED
UPS UNINTERRUPABLE POWER SUPPLY
UTIL UTILITY
V -------------------------------
VB VALVE BOX
VC VERTICAL CURVE
VCT VINYL COMPOSITION TILE
VEH VEHICLE
VEL VELOCITY
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VIN VINYL
VGYP VINYL COATED GYPSUM BOARD
VIP VERY IMPORTANT PERON
VWB VINYL WALL BASE
W -------------------------------
W WEST OR WIDE
WC WATER CLOSET
WD WOOD
WM WIRE MESH PARTITION
WSP WELDED STEEL PIPE
WT WEIGHT
W/O WITHOUT
W/ WITH
WWF WELDED WIRE FABRIC
ARCHITECTURAL ABBREVIATIONS & SYMBOLS
INDEX OF DRAWINGS
NUMBERING SYSTEM:
ANNOTATION CALLOUTS/DRAWING SYMBOLS
XX100
DISCIPLINE:
C - CIVIL
L - LANDSCAPE
A - ARCHITECTURE
M - MECHANICAL
E - ELECTRICAL
P - PLUMBING
S - STRUCTURAL
K - FOOD SERVICE
DISCIPLINE MODIFIER
SHEET NUMBER WITHIN SERIES
REFER TO A/E/C CAD STANDARD FOR
SHEET NUMBERING STANDARDS
INTERIOR ELEVATION
SHEET NUMBER
SECTION
SHEET NUMBER
ENLARGMENT DETAIL
SHEET NUMBER
EXTERIOR ELEVATION
4 2
A204
A201
A301
A401
ELEVATION NUMBER
SHEET NUMBER
REVISION TAG1
PLAN NORTH
NORTH ARROW w/
TRUE NORTH
INDICATION
ROOM TAG
DOOR TAG
WINDOW TAG
PARTITION TYPE
SPOT ELEVATION
LEVEL NAME
SPECIFICATION
NOTE
ROOM
100'
LEVEL 01
100'
XX XX XX.A1
315 6200 6000 6000 6000 6200 315
31025
AE301
AE301
AE201
AE201
AE201
AE301
AE301
261 m²
SUNSHADE
STEEL COLUMN, PAINT
SPLASH BLOCK (TYP)
DOWNSPOUT (TYP)
CONCRETE SLAB, SEE
STRUCTURAL
A
1 2 3 4 5 6
B
AE301
AE301
AE201
AE201
AE201
AE301
AE301
265 6200 6000 6000 6000 6200 265
:1
GUTTER (TYP)
30930
LIGHTNING
PROTECTION AIR
TERMINAL (TYP)
PREFINISHED
INSULATED METAL
ROOF ASSEMBLY
PREFINISHED METAL WALL
PANEL OVER GIRT FRAMING
DOWNSPOUT (TYP)
A
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
GENERAL SHEET NOTES
X:\REVIT PROJECTS\KUWAIT\2023\KU-509974-2 - APACHE ALERT MISSION FACILITIES\G1 - SUNSHADE - SINGLE ROW\KU-509974-2G1-DM-A-SUNS_RVT25.rvt
7/14/2026 7:56:35 AM
/1
/2
:5 :3
A
M
AE101
F L O
O R
A N
D R
O O
F P
L A
N
A L I A
L S
A L E
M A
B K
U W
A
IT
D .G
U R
A K
D G
U R
A K
C .G
O R
D O
N
J U
L Y
W E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
A F
R E
E M
A N K
U -5
-2
G -A
E
S U
N S
H A
D E
S
IN
G
L E
R O
W
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
IE
S
G1
C D
C
1 : 1001
GROUND FLOOR PLAN
0 1051 2 3 4
1:100
GROSS AREA
NAME AREA
SUNSHADE 256 m² 1. CONSTRUCTION SHALL BE AS INDICATED IN DRAWINGS IN TANDEM WITH
CONTRACT SPECIFICATIONS
2. CANOPY PLANS AND ELEVATIONS PROVIDED FOR GENERAL PURPOSES ONLY.
THE FULL CANOPY DESIGN AND INSTALLATION SHALL BE PROVIDED BY
CANOPY MANUFACTURER.
3. REFER TO CIVIL DRAWINGS FOR LOCATION AND TRUE NORTH, GRADE
SLOPES, AND STRIPING MARKS.
1 : 1002
ROOF PLAN
AE301
AE301
AE301
AE301
SUNSHADE
STEEL BEAMS, SEE
STRUCTURAL
PREFINISHED METAL WALL
PANEL OVER GIRT FRAMING
LIGHTING FIXTURE,
SEE ELECTRICAL
6200 6000 6000 6000 6200
30400
STRUCTURAL
FRAMING
LIGHTING FIXTURE,
SEE ELECTRICAL
LIGHTING FIXTURE,
SEE ELECTRICAL
STRUCTURAL COLUMN,
SEE STRUCTURAL
BEAM, SEE
STRUCTURAL
PREFINISHED
METAL WALL PANEL
COLUMN, SEE
STRUCTURAL
BEAM, SEE
STRUCTURAL
A
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
GENERAL SHEET NOTES
X:\REVIT PROJECTS\KUWAIT\2023\KU-509974-2 - APACHE ALERT MISSION FACILITIES\G1 - SUNSHADE - SINGLE ROW\KU-509974-2G1-DM-A-SUNS_RVT25.rvt
7/14/2026 7:56:35 AM
/1
/2
:5 :3
A
M
AE102
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
A L I A
L S
A L E
M A
B K
U W
A
IT
D .G
U R
A K
D G
U R
A K
C .G
O R
D O
N
J U
L Y
W E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
A F
R E
E M
A N K
U -5
-2
G -A
E
S U
N S
H A
D E
S
IN
G
L E
R O
W
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
IE
S
G1
C D
C
1 : 1001
REFLECTED CEILING PLAN
0 1051 2 3 4
1:100
1. REFLECTED CEILING PLAN SHOWN FOR LAYOUT AND COORDINATION
PURPOSES ONLY. COORDINATE MECHANICAL EQUIPMENT, ELECTRICAL
LIGHTING, AND FIRE PROTECTION WITH RESPECTIVE DRAWINGS.
2. FIXTURE LEGENDS- SEE EACH DISCIPLINE DRAWINGS.
3. STRUCTURAL FRAMING COMPONENTS SHALL BE SHOP PRIMED AND FINISHED
PER SPEC.
GROUND FLOOR
BO ROOF
B
AE301
AE301
GUTTER (TYP)
TOR
LIGHTNING PROTECTION
AIR TERMINAL (TYP)
2:12
DOWNSPOUT (TYP)
CONCRETE SLAB, SEE
STRUCTURAL
GRADE, SEE CIVIL
SPLASH BLOCK (TYP)
PREFINISHED METAL
WALL PANEL
STEEL COLUMN, PAINT
PREFINISHED INSULATED
METAL ROOF ASSEMBLY
A
PREFINISHED INSULATED
METAL ROOF ASSEMBLY
GROUND FLOOR
BO ROOF
123456
AE301
AE301
DOWNSPOUT (TYP)
TOR
LIGHTNING PROTECTION
AIR TERMINAL (TYP)
GUTTER (TYP)
PREFINISHED INSULATED
METAL ROOF ASSEMBLY
SPLASH BLOCK (TYP)
GRADE, SEE CIVIL
STEEL COLUMN, PAINT
CONCRETE SLAB, SEE
STRUCTURAL
GROUND FLOOR
BO ROOF
1 2 3 4 5 6
AE301
AE301
TOR
LIGHTNING PROTECTION
AIR TERMINAL (TYP)
PREFINISHED
METAL WALL PANEL
GRADE, SEE CIVIL
STEEL FRAME -PAINT
CONCRETE SLAB,
SEE STRUCTURAL
PREFINISHED INSULATED
METAL ROOF ASSEMBLY
GROUND FLOOR
BO ROOF
B
AE301
AE301
TOR
A
GUTTER (TYP)
DOWNSPOUT (TYP)
GRADE, SEE CIVIL
PREFINISHED METAL
WALL PANEL
STEEL COLUMN, PAINT
PREFINISHED INSULATED
METAL ROOF ASSEMBLY
2:12
SPLASH BLOCK (TYP)
CONCRETE SLAB,
SEE STRUCTURAL
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
GENERAL SHEET NOTES
X:\REVIT PROJECTS\KUWAIT\2023\KU-509974-2 - APACHE ALERT MISSION FACILITIES\G1 - SUNSHADE - SINGLE ROW\KU-509974-2G1-DM-A-SUNS_RVT25.rvt
7/14/2026 7:56:35 AM
/1
/2
:5 :3
A
M
AE201
B U
IL
D
IN
G
E L E
V A
T
IO
N S
A L I A
L S
A L E
M A
B K
U W
A
IT
D .G
U R
A K
D G
U R
A K
C .G
O R
D O
N
J U
L Y
W E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
A F
R E
E M
A N K
U -5
-2
G -A
E
S U
N S
H A
D E
S
IN
G
L E
R O
W
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
IE
S
G1
C D
C
1 : 1003
BUILDING ELEVATION B
1 : 1002
BUILDING ELEVATION A
0 1051 2 3 4
1:100 1 : 1001
BUILDING ELEVATION C
1. REFER TO SA SERIES FOR EXTERIOR FINISHES.
2. REFERENCE ELECTRICAL DRAWINGS FOR DETAIL OF EXTERIOR LIGHTING.
1 : 1004
BUILDING ELEVATION D
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
GENERAL SHEET NOTES
SPECIFICATIONS NOTES
X:\REVIT PROJECTS\KUWAIT\2023\KU-509974-2 - APACHE ALERT MISSION FACILITIES\G1 - SUNSHADE - SINGLE ROW\KU-509974-2G1-DM-A-SUNS_RVT25.rvt
7/14/2026 7:56:35 AM
/1
/2
:5 :3
A
M
AE201
B U
IL
D
IN
G
E L E
V A
T
IO
N S
A L I A
L S
A L E
M A
B K
U W
A
IT
D .G
U R
A K
D G
U R
A K
C .G
O R
D O
N
J U
L Y
W E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
A F
R E
E M
A N K
U -5
-2
G -A
E
S U
N S
H A
D E
S
IN
G
L E
R O
W
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
IE
S
G1
C D
C
GROUND FLOOR
BO ROOF
1 2 3 4 5 6
AE301
AE301
CONCRETE SLAB,
SEE STRUCTURAL
SUNSHADE
STEEL COLUMN,
SEE STRUCTURAL
TOR
LIGHTING
FIXTURES, SEE
ELECTRICAL
FOUNDATION,
SEE STRUCTURAL
CONCRETE BEAM,
SEE STRUCTURAL
6200 6000 6000 6000 6200
PREFINISHED
METAL WALL PANEL
CONCRETE SLAB,
SEE STRUCTURAL
CONCRETE SLAB,
SEE STRUCTURAL
PREFINISHED
INSULATED METAL
ROOF ASSEMBLY
GROUND FLOOR
BO ROOF
B
AE301
AE301
SUNSHADE
STEEL COLUMNS AND
BEAMS, SEE STRUCTURAL
2:12
PREFINISHED INSULATED
METAL ROOF ASSEMBLY
TOR
LIGHTNING PROTECTION,
SEE ELECTRICAL
LIGHTING FIXTURES,
SEE ELECTRICAL
CONCRETE SLAB,
SEE STRUCTURAL
FOUNDATION,
SEE STRUCTURAL
GUTTER (TYP)
PREFINISHED
METAL WALL PANEL DOWNSPOUT (TYP)
A
GRADE, SEE CIVIL
SPLASH BLOCK (TYP)3
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
GENERAL SHEET NOTES
X:\REVIT PROJECTS\KUWAIT\2023\KU-509974-2 - APACHE ALERT MISSION FACILITIES\G1 - SUNSHADE - SINGLE ROW\KU-509974-2G1-DM-A-SUNS_RVT25.rvt
7/14/2026 7:56:35 AM
/1
/2
:5 :3
A
M
AE301
B U
IL
D
IN
G
S E
C T
IO
N
A L I A
L S
A L E
M A
B K
U W
A
IT
D .G
U R
A K
D G
U R
A K
C .G
O R
D O
N
J U
L Y
W E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
A F
R E
E M
A N K
U -5
-2
G -A
E
S U
N S
H A
D E
S
IN
G
L E
R O
W
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
IE
S
G1
C D
C
1 : 1001
SECTION 1
1 : 1002
SECTION 2
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
X:\REVIT PROJECTS\KUWAIT\2023\KU-509974-2 - APACHE ALERT MISSION FACILITIES\G1 - SUNSHADE - SINGLE ROW\KU-509974-2G1-DM-A-SUNS_RVT25.rvt
7/14/2026 7:56:36 AM
/1
/2
:5 :3
A
M
AE901
P E
R S
P E
C T
IV
E
V
IE
W S
A L I A
L S
A L E
M A
B K
U W
A
IT
D .G
U R
A K
D G
U R
A K
C .G
O R
D O
N
J U
L Y
W E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
A F
R E
E M
A N K
U -5
-2
G -A
E
S U
N S
H A
D E
S
IN
G
L E
R O
W
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
IE
S
G1
C D
C
NTS1
PERSPECTIVE 1
C C C C C
PPG1-1
654321
B
A
US Army Corps of Engineers®
SHEET ID
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
TE
D B
Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
TE
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
G
F
E
D
C
B
A
D
AT
E
File Path:
Plot Date:
M
AR
K D
ES
C
R
IP
TI
O
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
PL
O
T D
AT
E:
FI
LE
N
AM
E:
M
ID
D
LE
E
AS
T D
IS
TR
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
PR
IN
C E
FR
ED
ER
IC
K D
R
IV
E, W
IN
C
H
ES
TE
R
, V A
GENERAL SHEET NOTES
X:\REVIT PROJECTS\KUWAIT\2023\KU-509974-2 - APACHE ALERT MISSION FACILITIES\G1 - SUNSHADE - SINGLE ROW\KU-509974-2G1-DM-E-SUNS_RVT25.rvt
7/9/2026 11:24:13 AM
7/ 9/
1:
:1
AM
EL101
LI
G
H
TI
N G
P
LA
N
G R
O U
N D
F
LO
O R
AL
I A
L
SA
LE
M
A B, K U
W
AI
T N
. C O
R B
IN
N . C
O R
B
IN
N . H
A N
N A
JU
LY
W
2E R
R
A
KM
O
D
K U
W
AI
T
AI
R F
O R
C E
KU
-5
4-
A . F
R E
E M
A
N KU
-5
4-
2G 1-
EL
SU
N
SH
AD
E
- S
IN
G
LE
R
O W
KU
W
AI
T
AP
AC
H E
AL
ER
T
FA
C
IL
IT
ES
G1
C D
C
1 : 1001 LIGHTING PLAN - GROUND FLOOR
1.
2.
3.
FOR ELECTRICAL LEGEND, AND ABBREVIATION AND
EQUIPMENT MOUNTING HEIGHTS SEE SHEETS SE001 -
SE003 (STANDARD VOLUME).
FOR LIGHTING FIXTURE DETAILS AND SCHEDULE SEE
SE501 AND SE503 (STANDARD VOLUME) RESPECTIVELY.
LIGHT FIXTURES RATED FOR OUTDOOR USE AND OF THE
ENCLOSED GASKET TYPE. LIGHTS SHOULD BE
CONTROLLED FOR AUTOMATIC FULL ON VIA DUSK-DAWN
TIMER (SEE EP501 DETAIL 2).
WP WP WP WPWP W
P
STANCHION MOUNTED
POWER PANEL PPG1
(SEE EP501)
SURFACE MOUNTED
EXTERIOR
RECEPTACLE IN IP66
RATED ENCLOSURE.
MOUNTED +900mm
ABOVE GROUND (TYP)
SUNSHADE
ROUTE SURFACE MOUNTED IMC
RACEWAY ALONG STRUCTURAL
MEMBERS TO VERTICAL DROP
TO EACH RECEPTACLE (TYP)
PPG1-2
654321
B
A
PPG1
US Army Corps of Engineers®
SHEET ID
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
TE
D B
Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
TE
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
G
F
E
D
C
B
A
D
AT
E
File Path:
Plot Date:
M
AR
K D
ES
C
R
IP
TI
O
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
PL
O
T D
AT
E:
FI
LE
N
AM
E:
M
ID
D
LE
E
AS
T D
IS
TR
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
PR
IN
C E
FR
ED
ER
IC
K D
R
IV
E, W
IN
C
H
ES
TE
R
, V A
GENERAL SHEET NOTES
X:\REVIT PROJECTS\KUWAIT\2023\KU-509974-2 - APACHE ALERT MISSION FACILITIES\G1 - SUNSHADE - SINGLE ROW\KU-509974-2G1-DM-E-SUNS_RVT25.rvt
7/9/2026 11:24:13 AM
7/ 9/
1:
:1
AM
EP101
PO
W
ER
P
LA
N
G
R O
U N
D F
LO
O
R
AL
I A
L
SA
LE
M
A B, K U
W
AI
T N
. C O
R B
IN
N . C
O R
B
IN
N . H
A N
N A
JU
LY
W
2E R
R
A
KM
O
D
K U
W
AI
T
AI
R F
O R
C E
KU
-5
4-
A . F
R E
E M
A
N KU
-5
4-
2G 1-
EP
SU
N
SH
AD
E
- S
IN
G
LE
R
O W
KU
W
AI
T
AP
AC
H E
AL
ER
T
FA
C
IL
IT
ES
G1
C D
C
1 : 1001 POWER PLAN - GROUND FLOOR
1.
2.
3.
4.
FOR ELECTRICAL LEGEND, AND ABBREVIATION AND
EQUIPMENT MOUNTING HEIGHTS SEE SHEETS SE001 - SE003
(STANDARD VOLUME).
FOR ELECTRICAL ONE-LINE DIAGRAMS SEE SHEET EP-601.
COORDINATE ALL RECEPTACLES LOCATION AND HEIGHT
WITH CONTRACTING OFFICER BEFORE INSTALLATION.
CIRCUITS MUST TAKE THE MOST DIRECT PATH TO MINIMIZE
VOLTAGE DROP.
STRUT FOR MOUNTING
EQUIPMENT (TYP)
80mm RIGID GALVANIZED
STEEL PIPE CONCRETE
FILLED (TYP 2)
WP, RCD DUPLEX
RECEPTACLE
(IP66 ENCLOSURE)
LC-1
(IP66)
CONCRETE EQUIPMENT PAD
FINISHED GRADE
TO NEAREST
BUILDING PANEL
ON SITE - INSTALL
BASED ON ACTUAL
SITE CONDITIONS
TO SUNSHADE
LIGHTING
TYPICAL FOR
PPG1
(IP66)
MOUNT STANCHION FACING
GENERAL DIRECTION OF
THE UTILITY POINT OF
CONNECTION. EXACT
LOCATION MAY VARY.
FOR LIGHTING CONTACTOR
CONTROL DIAGRAM SEE
SE504 DETAIL 2, DUSK-
DAWN TIMER
MOUNT PANEL
+1200mm ABOVE
GROUND TO BOTTOM
US Army Corps of Engineers®
SHEET ID
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
TE
D B
Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
TE
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
G
F
E
D
C
B
A
D
AT
E
File Path:
Plot Date:
M
AR
K D
ES
C
R
IP
TI
O
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
PL
O
T D
AT
E:
FI
LE
N
AM
E:
M
ID
D
LE
E
AS
T D
IS
TR
IC
T
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
PR
IN
C E
FR
ED
ER
IC
K D
R
IV
E, W
IN
C
H
ES
TE
R
, V A
X:\REVIT PROJECTS\KUWAIT\2023\KU-509974-2 - APACHE ALERT MISSION FACILITIES\G1 - SUNSHADE - SINGLE ROW\KU-509974-2G1-DM-E-SUNS_RVT25.rvt
7/9/2026 11:24:13 AM
7/ 9/
1:
:1
AM
EP501
PO
W
ER
A
N D
L
IG
H
TI
N G
D
ET
AI
LS
AL
I A
L
SA
LE
M
A B, K U
W
AI
T N
. C O
R B
IN
N . C
O R
B
IN
N . H
A N
N A
JU
LY
W
2E R
R
A
KM
O
D
K U
W
AI
T
AI
R F
O R
C E
KU
-5
4-
A . F
R E
E M
A
N KU
-5
4-
2G 1-
EP
SU
N
SH
AD
E
- S
IN
G
LE
R
O W
KU
W
AI
T
AP
AC
H E
AL
ER
T
FA
C
IL
IT
ES
G1
C D
C
NTS1 STANCHION MOUNTED PANEL DETAIL
SUNSHADE
PPG1
TO FACILITY D, MSWA, LP2
SEE FACILITY D, EP602
1 SETS OF (2) 1/C-50mm2 CU/XLPE/PVC + 1-16mm2 G 53mm PVC
SCH 40 TRANSITION TO IMC/EMT ABOVE GROUND
1- 16mm2 CU/PVC GROUNDING ELECTRODE
CONDUCTOR IN YELLOW-GREEN SHEATH
US Army Corps of Engineers®
SHEET ID
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
TE
D B
Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
TE
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
G
F
E
D
C
B
A
D
AT
E
File Path:
Plot Date:
M
AR
K D
ES
C
R
IP
TI
O
N
PL
O
T D
AT
E:
FI
LE
N
AM
E:
M
ID
D
LE
E
AS
T D
IS
TR
IC
T
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
PR
IN
C E
FR
ED
ER
IC
K D
R
IV
E, W
IN
C
H
ES
TE
R
, V A
GENERAL SHEET NOTES
X:\REVIT PROJECTS\KUWAIT\2023\KU-509974-2 - APACHE ALERT MISSION FACILITIES\G1 - SUNSHADE - SINGLE ROW\KU-509974-2G1-DM-E-SUNS_RVT25.rvt
7/9/2026 11:24:13 AM
7/ 9/
1:
:1
AM
EP601
O N
E-
LI
N E
D
IA
G R
AM
AL
I A
L
SA
LE
M
A B, K U
W
AI
T N
. C O
R B
IN
N . C
O R
B
IN
N . H
A N
N A
JU
LY
W
2E R
R
A
KM
O
D
K U
W
AI
T
AI
R F
O R
C E
KU
-5
4-
A . F
R E
E M
A
N KU
-5
4-
2G 1-
EP
SU
N
SH
AD
E
- S
IN
G
LE
R
O W
KU
W
AI
T
AP
AC
H E
AL
ER
T
FA
C
IL
IT
ES
G1
C D
C
NTS1 ONE-LINE DIAGRAM
1.
2.
3.
FOR ELECTRICAL LEGEND, AND ABBREVIATION SEE SHEETS SE001 - SE003
(STANDARD VOLUME).
PROVIDE LOCKABLE BREAKER FOR ALL SPECIAL SYSTEMS EQUIPMENT
(IDS, ACS, CCTV AND FACP).
DEGREE OF PROTECTION AGAINST EARTH LEAKAGE THROUGHOUT THE
ELECTRICAL INSTALLATION SHALL BE OF THE FOLLOWING:
MAXIMUM 30mA TRIP RATING - FOR UNDER WATER LIGHTING
MAXIMUM 30mA TRIP RATING - ALL SOCKET OUTLETS AND
DOMESTIC APPARATUS
300mA TRIP RATING - LIGHTING CIRCUITS AND ALL OTHER
APPARATUS AND EQUIPMENT INCLUDING HVAC, MOTORS AND
PUMPS.
Notes:
Total Dem. Load with 15% Spare: 2608 VA
Total Conn. Load with 15% Spare: 2608 VA Total Est. Demand: 9 A
Total Conn.: 9 A Total Est. Demand: 2268 VA
Lighting 200 VA 100.00% 200 VA Total Conn. Load: 2268 VA Receptacle 2070 VA 100.00% 2070 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Total Amps: 9 A Total Load: 2268 VA
11 Space -- 1 -- -- 1 -- Space 12 9 Space -- 1 -- -- 1 -- Space 10 7 Spare 16 A 1 0 VA 0 VA 1 16 A Spare 8 5 Spare 16 A 1 0 VA 0 VA 1 16 A Spare 6 3 SPD 20 A 1 0 VA 0 VA 1 16 A Spare 4 1 SUNSHADE LIGHTING 4 4 21 16 A 1 200 VA 2070 VA 1 20 A 21 4 4 EXTERIOR RECEPTACLES 2
CKT Circuit Description Cond mm2 Gnd mm2 Conduit mm Trip Poles R R
Poles Trip Conduit mm Gnd mm2 Cond mm2 Circuit Description CKT
Enclosure: IP66 Frequency: 50 Hz MCB Rating: 60 A Mounting: Surface Wires: 2 Mains Rating: 60 A
Supply From: Phases: 1 Mains Type: MAIN CB Location: Volts: 240 A.I.C. Rating: 22kAIC
Branch Panel: PPG1
MSWA FACILITY D, PARKING LOT
FACILITY D, EMDPD
SUNSHADE
1 4
PPG1
3 5
654321
B
A
US Army Corps of Engineers®
SHEET ID
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
TE
D B
Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
TE
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
G
F
E
D
C
B
A
D
AT
E
File Path:
Plot Date:
M
AR
K D
ES
C
R
IP
TI
O
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
PL
O
T D
AT
E:
FI
LE
N
AM
E:
M
ID
D
LE
E
AS
T D
IS
TR
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
PR
IN
C E
FR
ED
ER
IC
K D
R
IV
E, W
IN
C
H
ES
TE
R
, V A
SHEET KEY NOTES
GENERAL SHEET NOTES
X:\REVIT PROJECTS\KUWAIT\2023\KU-509974-2 - APACHE ALERT MISSION FACILITIES\G1 - SUNSHADE - SINGLE ROW\KU-509974-2G1-DM-E-SUNS_RVT25.rvt
7/9/2026 11:24:12 AM
7/ 9/
1:
:1
AM
EG101
G R
O U
N D
IN
G
P
LA
N
G R
O U
N D
F
LO
O R
AL
I A
L
SA
LE
M
A B, K U
W
AI
T N
. C O
R B
IN
N . C
O R
B
IN
N . H
A N
N A
JU
LY
W
2E R
R
A
KM
O
D
K U
W
AI
T
AI
R F
O R
C E
KU
-5
4-
A . F
R E
E M
A
N KU
-5
4-
2G 1-
EG
SU
N
SH
AD
E
- S
IN
G
LE
R
O W
KU
W
AI
T
AP
AC
H E
AL
ER
T
FA
C
IL
IT
ES
G1
C D
C
1 : 1001 GROUNDING PLAN - GROUND FLOOR
1.
2.
3.
4.
5.
6.
7.
8.
FOR ELECTRICAL LEGEND, AND ABBREVIATION SEE SHEETS
SE001 - SE003 (STANDARD VOLUME).
PROVIDE LIGHTNING PROTECTION IN ACCORDANCE WITH
NFPA 780.
SEE SE500 SERIES DRAWINGS FOR GROUNDING AND
LIGHTNING PROTECTION DETAILS.
BOND ALL METALLIC PIPING, ETC. AT THE SERVICE.
GROUND RING SHALL BE LOCATED 1500 mm NOMINAL FROM
THE OUTSIDE EDGE OF THE BUILDING FOUNDATION, AT LEAST
BELOW THE DRIP LINE FOR THE FACILITY AND 762 mm BELOW
FINISHED GRADE UNLESS OTHERWISE NOTED.
THE RESISTANCE BETWEEN EARTH ELECTRODES AND THE
GENERAL MASS OF EARTH SHALL NOT EXCEED TEN (10) OHM.
INSTALL ADDITIONAL EARTH ELECTRODES IN PARALLEL,
GROUND RODS OR PROVIDE A NON-CORROSIVE GROUND
ENHANCEMENT MATERIAL NOT DEPENDENT ON MOISTURE
(BENTONITE CLAY IS NOT ACCEPTABLE), IF THESE FIGURES
ARE NOT MET. CONTRACTOR SHALL PROVIDE TESTING TO
CONFIRM TEN (10) OHM OR LESS TO GROUND.
CONTRACTOR SHALL PROVIDE TESTING REPORT TO CONFIRM
TEN (10) OHM OR LESS TO GROUND.
SYSTEM GROUNDING SHALL FOLLOW BS7671, TN-S
GROUNDING METHOD.
1.
2.
3.
4.
5.
6.
120 mm² COPPER MAIN GROUND RING.
70 mm² BARE STRANDED CLASS 1 COPPER CONDUCTOR
CONCEAL CONDUCTORS IN PVC CONDUIT (TYP).
INSTALL GROUND TEST WELL (TYP 2). SEE GROUNDING
STANDARD DETAILS ON SHEET SE-521.
INSTALL 19mm X 3M COPPER-CLAD STEEL GROUND ROD
(TYP).
COPPER LIGHTNING PROTECTION DOWN CONDUCTOR
FROM ROOF TERMINAL (TYP 2). SEE EG102.
GROUNDING ELECTRODE CONDUCTOR, 10mm2 CU WITH
YELLOW GREEN SHEATH.
70mm 2 COPPER DOWN CONDUCTOR IN CONCEAL IN 53mm CONDUIT CONNECT DIRECT
BURIED CABLE TO GROUND GRID (TYP)
SEE EG101
AIR TERMINAL
10MM X 600MM SOLID
COPPER (TYP)
COPPER LIGHTNING PROTECTION
CONDUCTOR 70 mm2 CROSS
SECTIONAL AREA (TYP)
654321
B
A
US Army Corps of Engineers®
SHEET ID
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
TE
D B
Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
TE
C O
N
TR
A C
T N
O
S O
LI
C
IT
A
TI
O
N N
O
G
F
E
D
C
B
A
D
AT
E
File Path:
Plot Date:
M
AR
K D
ES
C
R
IP
TI
O
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
PL
O
T D
AT
E:
FI
LE
N
AM
E:
M
ID
D
LE
E
AS
T D
IS
TR
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
PR
IN
C E
FR
ED
ER
IC
K D
R
IV
E, W
IN
C
H
ES
TE
R
, V A
GENERAL SHEET NOTES
X:\REVIT PROJECTS\KUWAIT\2023\KU-509974-2 - APACHE ALERT MISSION FACILITIES\G1 - SUNSHADE - SINGLE ROW\KU-509974-2G1-DM-E-SUNS_RVT25.rvt
7/9/2026 11:24:13 AM
7/ 9/
1:
:1
AM
EG111
LI
G
H
TN
IN
G
P R
O
TE
C
TI
O N
P
LA
N
R O
O F
AL
I A
L
SA
LE
M
A B, K U
W
AI
T N
. C O
R B
IN
N . C
O R
B
IN
N . H
A N
N A
JU
LY
W
2E R
R
A
KM
O
D
K U
W
AI
T
AI
R F
O R
C E
KU
-5
4-
A . F
R E
E M
A
N KU
-5
4-
2G 1-
EG
SU
N
SH
AD
E
- S
IN
G
LE
R
O W
KU
W
AI
T
AP
AC
H E
AL
ER
T
FA
C
IL
IT
ES
G1
C D
C
1 : 1001 LIGHTNING PROTECTION PLAN - ROOF
0 1051 2 3 4
1:100
1.
2.
3.
4.
5.
6.
7.
8.
9.
FOR ELECTRICAL LEGEND, SYMBOLS AND ABBREVIATION
SEE SE001 - SE003 (STANDARD VOLUME).
FOR LIGHTNING PROTECTION AND GROUNDING DETAILS
SEE SE500 SERIES SHEETS (STANDARD VOLUME) .
THE CONTRACTOR SHALL FURNISH ALL LABOR,
MATERIALS, EQUIPMENT AND SERVICES TO PROVIDE A
COMPLETE LIGHTNING PROTECTION SYSTEM FOR THE
SUNSHADE. THIS SYSTEM WILL COMPLY WITH NFPA 780.
BARE COPPER LIGHTNING PROTECTION MATERIALS
SHALL NOT BE INSTALLED ON ALUMINUM ROOF OR SIDING
OR OTHER ALUMINUM SURFACES AND VICE VERSA,
ALUMINUM LIGHTNING PROTECTION MATERIALS SHALL
NOT BE INSTALLED ON COPPER ROOFING OR COPPER
SIDING OR OTHER COPPER SURFACES. INSULATE USING
BIMETALLIC CONNECTORS AND FITTINGS SHALL BE USED
FOR SPLICING OR BONDING DISSIMILAR METALS.
CONNECTION TO GROUND ROD OR GROUND LOOP
CONDUCTOR SHALL BE MADE IN GROUND ROD
INSPECTION PIT.
AIR TERMINALS SHALL BE PLACED AT ALL UNPROTECTED
OUTSIDE CORNERS AND LOCATED INTERMEDIATELY ON
7.6 METER MAXIMUM SPACING AROUND THE ROOF
PERIMETER OR RIDGE AND WITHIN 600 mm OF OUTSIDE
EDGE.
ALL AREAS WHICH HAVE NOT BEEN PROVIDED WITH
LIGHTNING PROTECTION COMPONENTS ARE PROTECTED
FROM HIGHER ROOFS OR PORTIONS OF STRUCTURES.
THESE AREAS FALL WITHIN A "ZONE-OF-PROTECTION" AS
ESTABLISHED BY THE CURRENT EDITION OF NFPA 780
FOR PROTECTION AGAINST LIGHTNING.
CONDUCTORS SHALL INTERCONNECT ALL AIR TERMINALS
AND SHALL FORM A TWO-WAY PATH FROM EACH AIR
TERMINAL HORIZONTALLY OR DOWNWARD TO
CONNECTIONS WITH GROUND TERMINALS, EXCEPT FOR
VERTICAL ROOF MEMBERS, UPPER ROOF TO LOWER
ROOF TRANSITIONS, OR LOWER ROOF "DEAD ENDS ”.
ALL ADHESIVE TYPE FITTINGS SHALL BE SET IN PLACE
WITH AN APPLICATION OF COMPATIBLE ADHESIVE
COMPOUND.
| KU-509974-2_APACHE ALERT FACILITIES_VOL 7 OF 14_FACILITY G1_DRAWINGS_CDC_JUL 2026 |
| GENERAL |
| GI001 - FACILITY COVER SHEET |
| GI011 - INDEX OF DRAWINGS |
| STRUCTURAL |
| S-001 - GENERAL STRUCTURAL NOTES |
| SB101 - FOUNDATION PLAN |
| SB601 - FOOTING SCHEDULES |
| SF101 - FRAMING PLAN - GROUND FLOOR |
| SF102 - FRAMING PLAN - ROOF |
| ARCHITECTURAL |
| A-001 - GENERAL ARCHITECTURAL NOTES |
| AE101 - FLOOR AND ROOF PLAN |
| AE102 - REFLECTED CEILING PLAN |
| AE201 - BUILDING ELEVATIONS |
| AE301 - BUILDING SECTION |
| AE901 - PERSPECTIVE VIEWS |
| ELECTRICAL |
| EL101 - LIGHTING PLAN - GROUND FLOOR |
| EP101 - POWER PLAN - GROUND FLOOR |
| EP501 - POWER AND LIGHTING DETAILS |
| EP601 - ONE-LINE DIAGRAM |
| EG101 - GROUNDING PLAN - GROUND FLOOR |
| EG111 - LIGHTNING PROTECTION PLAN - ROOF |
File details come from the government source that posted it. Updated .