VOL 10 OF 14_FACILITY K_DRAWINGS_CDC_JUL 2026.pdf
PDF 13 MB Posted
- Attached to
- Apache Alert Mission Complex
- Solicitation number
- W912ER26RA016
About this file
This file is Volume 10 of a 14-volume set of architectural and structural drawings for Facility K (Substation) of the Kuwait Apache Alert Mission Facilities project.
The drawings are prepared for the U.S. Army Corps of Engineers, Middle East District, under Solicitation No. and Contract No. W912ER26RA016, issued in July 2026, for the Kuwait Ministry of Defence and Kuwait Air Force at Ali Al Salem Air Base, Kuwait. The 374-square-meter substation facility is a single-story, Type IA construction with 2-4 hour fire resistance ratings, designed to house electrical infrastructure including high-tension and low-tension rooms, transformer room, generator set room, battery room, and fire protection room. The facility must comply with Kuwait Fire Forces requirements, International Building Code 2021, NFPA standards (including NFPA 72 for fire alarm systems), and Unified Facilities Criteria. The design incorporates reinforced concrete construction with special moment-resisting frames for seismic design category D, concrete slabs on grade, masonry walls, and includes fire alarm detection systems, portable fire extinguishers (two 25-kilogram wheeled ABC units), and emergency lighting. The structure accommodates diesel fuel storage with generator belly tanks ranging from 202 to 2,423 liters and additional storage tanks of 1,350 liters each, requiring compliance with flammable liquid storage licensing. Wind design is based on basic wind speed of 174 kilometers per hour with exposure category C. The drawing set includes foundation plans, framing plans, structural details for beams and columns, masonry details, mechanical and electrical plans, fire alarm system layouts, and life safety analysis documentation.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US Army Corps of Engineers ®
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
VOLUME - FACILITY
VOLUME OF 14
FACILITY A - ALERT SHELTER
FACILITY C - LOGISTICS READINESS CENTER
FACILITY D - MAINTENANCE SUPPLY WAREHOUSE
FACILITY F - GUARD HOUSE
FACILITY H - PILOT READINESS FACILITY
FACILITY J - POL SHED
FACILITY K - SUBSTATION
FACILITY M - STORAGE SHADE
FACILITY N - WASH RACK SUNSHADE
FACILITY O - FIRE WATER PUMP HOUSE
GENERAL NOTES AND SITE DESIGN
INDEX OF VOLUMES
VOLUME
NUMBER
VOLUME TITLE
FACILITY G1 - SUNSHADES - SINGLE
FACILITY E - ALERT MAGAZINE
FACILITY STD - STANDARD DETAILS14
MIDDLE EAST DISTRICT
X:\REVIT PROJECTS\KUWAIT\2023\KU-509974-2 - APACHE ALERT MISSION FACILITIES\K - SUBSTATION\KU-509974-2K-DM-G-SUBS_RVT25.rvt
7/14/2026 4:17:52 PM
/1
/2
:1 :5
P
M
ALI AL SALEM AB, KUWAIT
KMOD – KUWAIT AIR FORCE
W912ER26RA016
JULY 2026
KU-509974-2
KUWAIT APACHE ALERT FACILITES
GI001
F A
C
IL
IT
Y
C O
V E
R S
H E
E T
A L I A
L S
A L E
M A
B K
U W
A
IT
C O
'B A
N N
O N
C O
'B A
N N
O N
E S
T
IL
L M
A N
J U
L Y
W E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
D R
A C
K M
A L E
S
K U
-5 -2
K -G
I0
S U
B S
T A
T
IO
N
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
E
S
K
C D
C
K - SUBSTATION10
of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
X:\REVIT PROJECTS\KUWAIT\2023\KU-509974-2 - APACHE ALERT MISSION FACILITIES\K - SUBSTATION\KU-509974-2K-DM-G-SUBS_RVT25.rvt
7/14/2026 4:15:58 PM
/1
/2
:1 :5
P
M
GI011
IN
D
E X
O F
D R
A W
IN
G
S
A L I A
L S
A L E
M A
B K
U W
A
IT
C O
'B A
N N
O N
C O
'B A
N N
O N
E S
T
IL
L M
A N
J U
L Y
W E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
D R
A C
K M
A L E
S
K U
-5 -2
K -G
I0
S U
B S
T A
T
IO
N
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
E
S
K
C D
C
INDEX OF DRAWINGS
KU-509974-2 - FACILITY K - SUBSTATION
SHEET
ID
FILE NAME REV. NO.
AM/COP
NO.
SHEET TITLE
GENERAL
GI001 KU-509974-2K-GI001 FACILITY COVER SHEET
GI011 KU-509974-2K-GI011 INDEX OF DRAWINGS
GI041 KU-509974-2K-GI041 BUILDING CODE AND LIFE SAFETY ANALYSIS
GI101 KU-509974-2K-GI101 LIFE SAFETY PLAN - GROUND FLOOR - A1&A3
GI102 KU-509974-2K-GI102 LIFE SAFETY PLAN - GROUND FLOOR - A2
STRUCTURAL
S-001 KU-509974-S-001 GENERAL NOTES
SB101 KU-509974-SB101 FOUNDATION PLAN
SF101 KU-509974-SF101 FRAMING PLAN - GROUND FLOOR
SF102 KU-509974-SF102 FRAMING PLAN - ROOF
SF301 KU-509974-SF301 FLOOR FRAMING SECTIONS
SF501 KU-509974-SF501 STRUCTURAL DETAILS
SF502 KU-509974-SF502 STRUCTURAL DETAILS
SF503 KU-509974-SF503 SMF BEAMS DETAILS
SF504 KU-509974-SF504 SMF COLUMN DETAILS
SF505 KU-509974-SF505 GRAVITY BEAMS AND SLAB DETAILS
SF506 KU-509974-SF506 GRADE BEAMS DETAILS
SF507 KU-509974-SF507 MASONRY DETAILS
SF508 KU-509974-SF508 MESCELLANEOUS DETAILS
SF601 KU-509974-SF601 FRAMING SCHEDULES
ARCHITECTURAL
A-001 KU-509974-2K-A-001 GENERAL ARCHITECTURAL NOTES
AB101 KU-509974-2K-AB101
AIR BARRIER PLAN AND SECTION VIEWS - GROUND FLOOR -
A1 & A3
AB102 KU-509974-2K-AB102
AIR BARRIER PLAN AND SECTION VIEWS - GROUND FLOOR -
A2
AE101 KU-509974-2K-AE101 GROUND FLOOR PLAN - A1 & A3
AE102 KU-509974-2K-AE102 GROUND FLOOR PLAN - A2
AR101 KU-509974-2K-AR101 GROUND FLOOR REFLECTED CEILING PLAN - A1 & A3
AR102 KU-509974-2K-AR102 GROUND FLOOR REFLECTED CEILING PLAN - A2
AE111 KU-509974-2K-AE111 ROOF PLAN - A1 & A3
AE112 KU-509974-2K-AE112 ROOF PLAN - A2
AE201 KU-509974-2K-AE201 BUILDING ELEVATIONS - A1 & A3
AE202 KU-509974-2K-AE202 BUILDING ELEVATIONS - A2
AE301 KU-509974-2K-AE301 BUILDING SECTIONS - A1 & A3
AE302 KU-509974-2K-AE302 WALL SECTIONS
AE302 KU-509974-2K-AE302 BUILDING SECTIONS - A2
AE303 KU-509974-2K-AE303 WALL SECTIONS - A1, A2, A3
AE601 KU-509974-2K-AE601 DOOR SCHEDULE AND DETAILS - A1 & A3
AE602 KU-509974-2K-AE602 DOOR SCHEDULE AND DETAILS - A2
AE901 KU-509974-2K-AE901 PERSPECTIVE VIEW - A1 & A3
AE902 KU-509974-2K-AE902 PERSPECTIVE VIEW - A2
INTERIORS
IN101 KU-509974-2K-IN101 FINISHES & SIGNAGE PLAN - GROUND FLOOR - A1 & A3
IN102 KU-509974-2K-IN102 FINISHES & SIGNAGE PLAN - GROUND FLOOR - A2
INDEX OF DRAWINGS
KU-509974-2 - FACILITY K - SUBSTATION
SHEET
ID
FILE NAME REV. NO.
AM/COP
NO.
SHEET TITLE
FIRE PROTECTION
FA101 KU-509974-2K-FA101 FIRE ALARM SYSTEM PLAN - GROUND FLOOR - A1&A3
FA102 KU-509974-2K-FA102 FIRE ALARM SYSTEM PLAN - GROUND FLOOR - A2
FA501 KU-509974-2K-FA501
FIRE ALARM SYSTEM MOUNTING DETAILS - GROUND FLOOR -
OVERALL
FA502 KU-509974-2K-FA502
FIRE ALARM SYSTEM MOUNTING DETAILS - GROUND FLOOR -
OVERALL
FA601 KU-509974-2K-FA601 FIRE ALARM SCHEDULES AND DIAGRAMS
FA602 KU-509974-2K-FA602 FIRE ALARM SCHEDULES AND DIAGRAMS
MECHANICAL
MH101 KU-509974-2K-MH101 MECHANICAL PLAN - GROUND FLOOR - A1 & A3
MH102 KU-509974-2K-MH102 MECHANICAL PLAN - GROUND FLOOR- A2
MH111 KU-509974-2K-MH111 MECHANICAL PLAN - ROOF - A1 & A3
MH112 KU-509974-2K-MH112 MECHANICAL PLAN - ROOF- A2
MH601 KU-509974-2K-MH601 HVAC SCHEDULES - A1 & A3
MH602 KU-509974-2K-MH602 HVAC SCHEDULES- A2
MP101 KU-509974-2K-MP101 FUEL SYSTEM PLAN - GROUND FLOOR - A1 & A3
MP102 KU-509974-2K-MP102 FUEL SYSTEM PLAN - GROUND FLOOR- A2
MP501 KU-509974-2K-MP501 FUEL DETAILS
MP502 KU-509974-2K-MP502 FUEL SYSTEM SCHEMATIC - A1 & A3
MP503 KU-509974-2K-MP503 FUEL SYSTEM SCHEMATIC- A2
ELECTRICAL
EL101 KU-509974-2K-EL101 LIGHTING PLAN - GROUND FLOOR - SUBSTATION A1, A3
EL102 KU-509974-2K-EL102 LIGHTING PLAN - GROUND FLOOR - SUBSTATION A2
EL111 KU-509974-2K-EL111 LIGHTING PLAN - ROOF - SUBSTATION A1, A2, A3
EP101 KU-509974-2K-EP101 POWER PLAN - GROUND FLOOR - SUBSTATION A1, A3
EP102 KU-509974-2K-EP102 POWER PLAN - GROUND FLOOR - SUBSTATION A2
EP111 KU-509974-2K-EP111 POWER PLAN - ROOF - SUBSTATION A1, A2, A3
EP601 KU-509974-2K-EP601 ONE-LINE DIAGRAM - SUBSTATION A1
EP602 KU-509974-2K-EP602 ONE-LINE DIAGRAM - SUBSTATION A2
EP603 KU-509974-2K-EP603 ONE-LINE DIAGRAM - SUBSTATION A3
EG101 KU-509974-2K-EG101 GROUNDING PLAN - GROUND FLOOR - SUBSTATION A1, A3
EG102 KU-509974-2K-EG102 GROUNDING PLAN - GROUND FLOOR - SUBSTATION A2
EG111 KU-509974-2K-EG111
LIGHTNING PROTECTION PLAN - ROOF - SUBSTATION A1, A2,
A3
EG601 KU-509974-2K-EG601 GROUNDING RISER DIAGRAM - SUBSTATION A1, A3
EG602 KU-509974-2K-EG602 GROUNDING RISER DIAGRAM - SUBSTATION A2
2. BUILDING CODE REQUIREMENTS:
A. COMPLIANCE:
1) CONTRACTOR AWARDED THIS PROJECT IS REQUIRED TO COMPLY WITH KUWAIT REGULATIONS AND ALL OTHER APPLICABLE CODES, STANDARDS, AND
REQUIREMENTS.
2) ALL FIRE AND LIFE SAFETY DRAWING ARE CONCEPTUAL IN NATURE. CONTRACTOR DESIGN "SHOP" DRAWINGS MUST COMPLY WITH KUWAIT
REQUIREMENTS AND ALL OTHER APPLICABLE CODES, STANDARDS, AND REQUIREMENTS.
B. INTERNATIONAL CODE COUNCIL: "ICC"
1) IBC-2021 INTERNATIONAL BUILDING CODE. "IBC"
C. NATIONAL FIRE PROTECTION ASSOCIATION: "NFPA" AND/OR AS REFERENCED BY KFF.
1) NFPA 1-2024: FIRE CODE.
2) NFPA 4-2024: STANDARD FOR INTEGRATED FIRE PROTECTION AND LIFE SAFETY TESTING.
3) NFPA 10-2022: STANDARD FOR PORTABLE FIRE EXTINGUISHERS.
4) NFPA 70-2023: NATIONAL ELECTRICAL CODE.
5) NFPA 72-2022: FIRE ALARM AND SIGNALING CODE.
6) NFPA 80-2022: STANDARD FOR FIRE DOOR AND OTHER OPENING PROTECTIVES.
7) NFPA 105-2022: STANDARD FOR SMOKE DOOR ASSEMBLIES AND OTHER OPENING PROTECTIVES.
8) NFPA 170-2024: STANDARD FOR FIRE SAFETY AND EMERGENCY SYMBOLS.
9) NFPA 241-2022: STANDARD FOR SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS.
10) NFPA 2001-2022: STANDARD ON CLEAN AGENT FIRE EXTINGUISHING SYSTEMS.
D. STATE OF KUWAIT:
1) KFF KUWAIT FIRE FORCES "KFF" REQUIREMENTS FOR SAFETY AND FIRE PREVENTION.
2) KMOD KUWAIT MINISTRY OF DEFENCE.
3) MEP KUWAIT MILITARY ENGINEERING PROJECTS.
4) MPW KUWAIT MINISTRY OF PUBLIC WORKS.
5) MEW KUWAIT MINISTRY OF ELECTRICITY AND WATER.
E. UNIFIED FACILITIES CRITERIA: "UFC" AS APPLICABLE REFERENCE OR GUIDANCE:
"ALL UFC'S ARE FOR GUIDANCE AND WHEN LOCAL CODES DO NOT ADDRESS THE REQUIREMENT"
1) UFC 1-200-01-2022, CHANGE 3: (FEB24) DOD BUILDING CODE.
2) UFC 3-600-01-2016, CHANGE 6: (MAY21) FIRE PROTECTION ENGINEERING FOR FACILITIES.
F. UNIFIED FACILITIES GUIDE SPECIFICATIONS: “UFGS”: AS APPLICABLE REFERENCE OR GUIDANCE:
1) UFGS 01 33 00: SUBMITTAL PROCEDURES.
2) UFGS 10 44 16: FIRE EXTINGUISHERS.
3) UFGS 21 22 00.00 40: CLEAN AGENT FIRE EXTINGUISHING SYSTEMS
4) UFGS 28 31 70: INTERIOR FIRE ALARM SYSTEM, ADDRESSABLE.
G. UNITED STATES ARMY CORPS OF ENGINEERS: “USACE”
1) DIM-2022 DESIGN INSTRUCTIONS MANUAL: "USACE” MIDDLE EAST DISTRICT “MED”
2) EM ENGINEERING MANUAL “EM” 385-1-1:SAFETY AND HEALTH REQUIREMENTS:
H. DEFINITIONS:
1) THE DEFINITIONS CONTAINED IN THIS DOCUMENT SHALL APPLY TO THE TERMS USED IN THIS AND ALL REFERENCED DOCUMENTS. WHERE TERMS ARE NOT DEFINED IN THIS SECTION OR WITHIN ANOTHER SECTION/REFERENCE, THEY SHALL BE DEFINED USING THEIR ORDINARILY ACCEPTED MEANINGS WITHIN THE CONTEXT IN WHICH THEY ARE USED. MERRIAM-WEBSTER’S COLLEGIATE DICTIONARY, 11TH EDITION, IS AN EXAMPLE OF WHERE TO FIND THE ORDINARILY
ACCEPTED MEANING.
REFERENCES ARE NOT ALL INCLUSIVE.
OTHER RECOMMENDED STANDARDS SHALL BE USED WHERE REQUIRED TO SERVE AS CODES, STANDARDS, OR GUIDELINES FOR DESIGN, FABRICATION, AND
CONSTRUCTION WHEN NOT IN CONFLICT WITH THE ABOVE STANDARDS.
**BUILDING AND LIFE SAFETY CODE REQUIREMENTS MEETS OR EXCEEDS KFF REQUIREMENTS AND ARE PROVIDED WITHIN EACH SPECIFIC SECTION AS:
REQUIRED/ALLOWABLE AND PROVIDED/ACTUAL.
A. OCCUPANCY CLASSIFICATION:
1) KFF VOLUME 1, CHAPTER 4, TENTH: INDUSTRIAL: MEDIUM RISK
B. CONSTRUCTION TYPE:
1) KFF VOLUME 1, CHAPTER 5, TABLE NO. 5-1: TYPE: THE FIRST, FIRE RESISTANCE: 3-4 HOURS:
C. MIXED USE & OCCUPANCY: NOT APPLICABLE:
D. BUILDING HEIGHTS AND AREA
1) HEIGHT: IBC CHAP. 5, TABLES 504.3, 504.4 & 506.2:
HEIGHT IN METERS: (M) ALLOWABLE: 49 ACTUAL: 5.2
HEIGHT IN STORIES: ALLOWABLE: 11 ACTUAL: 1
2) AREA: IBC 2021, TABLE 506.2: SQUARE METER: (SM); UL=UNLIMITED ALLOWABLE: UL ACTUAL: 374
AREA FACTOR INCREASE FOR FRONTAGE DISTANCE: ALLOWABLE: YES ACTUAL: N/A
E. FIRE RESISTIVE REQUIREMENTS:
1) IBC-2021 SECTION 602, TABLES 601, 602, & 705.5: TYPE IA (FIRST TYPE) CONSTRUCTION: RATING IN HOURS:
PRIMARY STRUCTURAL FRAME: REQUIRED: 2 PROVIDED: 2
EXTERIOR BEARING WALLS: REQUIRED: 2 PROVIDED: 2
INTERIOR BEARING WALLS: REQUIRED: 2 PROVIDED: 2
EXTERIOR NONBEARING WALLS/PARTITIONS: KFF VOLUME 1, CHAPTER 5,TABLE NO. 5-2
INTERIOR NONBEARING WALLS/PARTITIONS: REQUIRED: 0 PROVIDED: 0
FLOOR CONSTRUCTION & SECONDARY STRUCTURAL MEMBERS: REQUIRED: 2 PROVIDED: 2
ROOF CONSTRUCTION & SECONDARY STRUCTURAL MEMBERS: REQUIRED: 1 PROVIDED: 1
2) KFF VOLUME 1, CHAPTER 5, SECOND, TABLE NO. 5-2: EXTERIOR BEARING AND NONBEARING EXTERIOR WALLS:
RISK DETERMINATION AND OCCUPANCY > 9 M: REQUIRED: >9 PROVIDED: >9
FIRE-RATING IN HOURS: REQUIRED: 0 PROVIDED: 0
3) KFF INTERIOR FIRE RESISTIVE REQUIREMENTS:
KFF VOLUME 1, CHAPTER 5, THIRD: (HOUR-HR) FIRE/SMOKE ZONES AND CLEAN AGENT SYSTEM SEPARATION: REQUIRED: 2 PROVIDED: N/A
4) HAZARDOUS MATERIALS STORAGE
I. KFF VOLUME 4: REMAIN BELOW MAXIMUM PERMISSIBLE CAPACITY REQUIRED: NO PROVIDED: NO II. KFF VOL 4, SECTION 1/2 LICENSE TO STORE FLAMMABLE LIQUIDS OVER 230 LITERS. REQUIRED: YES PROVIDED: NO
F. FIRE PROTECTION AND LIFE SAFETY SYSTEMS:
1) FIRE ALARM SYSTEM(S): "FIRE ALARM REPORTING WILL BE LOCAL ALARM ONLY PER KAF"
I. KFF VOLUME 6, CHAPTER 7: MANUAL AND AUTOMATIC FIRE WARNING SYSTEMS REQUIRED: YES PROVIDED: YES
2) FIRE SUPPRESSION SYSTEMS:
I. AUTOMATIC SPRINKLER SYSTEM: NO SPRINKLERS DUE TO ELECTRICAL HAZARDS:
KFF VOLUME 6, CHAPTER 7: REQUIRED: NO PROVIDED: NO
A. CLASSIFICATION OF OCCUPANCY:
1) KFF VOLUME 1, CHAPTER 4, TENTH: INDUSTRIAL: MEDIUM RISK
B. OCCUPANT LOAD: OCCUPANT LOAD FACTOR = PER PERSON (PP); ACTUAL NUMBER = PERSONS:
1) KFF VOLUME 1, CHAPTER 6, TABLE 6-2: INDUSTRIAL GROSS AREA (374 SM/10 PER PERSON (P/P): ALLOWABLE: 38 ACTUAL: 38
C. CAPACITY OF MEANS OF EGRESS: *KFF MINIMUM DOOR SIZE IS 850 MM:
1) KFF VOLUME 1, CHAPTER 6, SECOND, TABLE 6-1:
STAIRWAYS: OCCUPANT LOAD (OL) X 7.6 MM ALLOWABLE: N/A ACTUAL: N/A
OTHER: LEVEL COMPONENTS AND RAMPS: OL X 5.1 MM ALLOWABLE: 1500 ACTUAL: N/A
2) KFF VOLUME 1, CHAPTER 6, THIRTEENTH: NOT LESS THAN 1500 MM FOR MAIN CORRIDORS AND 1200 MM FOR SECONDARY CORRIDORS.
D. NUMBER OF EXITS:
1) KFF VOLUME 1, CHAPTER 6, THIRD: NOT LESS THAN (2) SEPARATE EXITS: REQUIRED: 2+ PROVIDED: 9
E. ARRANGEMENT OF MEANS OF EGRESS:
1) KFF VOLUME 1, CHAPTER 6, FOURTH: THE REQUIRED EXITS SHALL BE LOCATED AT A DISTANCE FROM ONE ANOTHER NOT LESS THAN
ONE-THE LENGTH OF THE OVERALL DIAGONAL DIMENSION OF THE BUILDING (28.3 M).
REQUIRED: 15 PROVIDED: 18
F. TRAVEL DISTANCE TO EXIT:
1) KFF VOLUME 1, CHAPTER 17, SECOND:
COMMON PATH TRAVEL: (CPT) (ONE-WAY) ALLOWABLE: 23 ACTUAL: N/A
TRAVEL DISTANCE: (TD) (TWO-WAY) ALLOWABLE: 30 ACTUAL: 10.7
2) KFF VOLUME 1, CHAPTER 6, SECTION 17: DEAD END: (DE) (CLOSED END) ALLOWABLE: 7.5 ACTUAL: N/A
3) EMERGENCY AND EXIT LIGHTS: KFF VOLUME 6, CHAPTER 8 AND VOLUME 3, PART 2: REQUIRED: YES PROVIDED: YES
G. INTERIOR FINISH & ROOF CLASSIFICATION LIMITS: KFF DOES NOT ADDRESS:
1) IBC-2021 TABLE 803.13 INTERIOR WALL AND CEILING FINISH: STORAGE: (CLASS A, B OR C) - SPRINKLERED:
INTERIOR STAIRS, RAMPS, AND PASSAGES: ALLOWABLE: C ACTUAL: C
CORRIDORS ACCESS STAIR/RAMPS: ALLOWABLE: C ACTUAL: C
ROOMS AND ENCLOSED SPACES: ALLOWABLE: C ACTUAL: C
2) IBC-2021, SECTION 804.4.2 FLOOR FINISH CLASS I OR II: FLOOR FINISH: STORAGE: ALLOWABLE: II ACTUAL: II
3) IBC-2021: TABLE 1505.1, ROOF COVERING CLASS A, B OR C: ROOF COVERING CLASSIFICATION: ALLOWABLE: B ACTUAL: B
H. ACCESSIBILITY: KUWAIT UNIVERSAL DESIGN CODE:
**BUILDING CODES AND LIFE SAFETY CODE REQUIREMENTS MEETS OR EXCEEDS KFF REQUIREMENTS**
4. CODE COMPLIANCE SITE DESIGN:
THE KUWAIT MINISTRY OF DEFENSE (KMOD), KUWAIT AIR FORCE (KAF) APACHE ALERT MISSION COMPLEX CODE COMPLIANCE SITE PLAN IS PRESENTED IN THE SITE DESIGN DRAWING SHEETS UNDER GI101, GI117, GI122, GI126, GI127, GI128, GI131, GI132, GI133 AND GI134.
**BUILDING CODES AND LIFE SAFETY CODE REQUIREMENTS MEETS OR EXCEEDS KFF REQUIREMENTS**
2. BUILDING CODE REQUIREMENTS: (CONTINUED)
F. FIRE PROTECTION AND LIFE SAFETY SYSTEMS: (CONTINUED)
2) FIRE SUPPRESSION SYSTEMS: (CONTINUED)
II. SUPPLEMENTAL SUPPRESSION SYSTEM(S):
A) FOAM-WATER SYSTEMS:
KFF VOLUME 2, PART 4, CHAPTER 7: REQUIRED: NO PROVIDED: NO
B) INTERNAL FIRE HOSE NETWORK:
KFF VOLUME 6, CHAPTER 8, MODERATE/HIGH HAZARD: 25 MM RUBBER HOSE AND HOSE CABINET: REQUIRED: NO PROVIDED: NO
STANDPIPE SYSTEM WITH 38 MM HOSE STATIONS: REQUIRED: NO PROVIDED: NO
3) EXTINGUISHING SYSTEM(S):
I. PORTABLE AND TROLLEY FIRE EXTINGUISHERS: REQUIRED: YES PROVIDED: YES
KFF VOLUME 6, CHAPTER 7 AND VOLUME 2, PART THREE, CHAPTER 1:
TROLLEY FIRE EXTINGUISHERS: REQUIRED: YES PROVIDED: YES
KFF VOLUME 4, APPENDIX 6 (TANK CAPACITY 3001-10000 LITERS, ADJACENT FACILITY >15M)
II. CLEAN AGENT EXTINGUISHING SYSTEMS:
KFF VOLUME 2, CHAPTER 7, SECTION 3/8/4, 1/3/8/4: REQUIRED: NO PROVIDED: NO
4) SMOKE VENTILATION AND EXHAUST SYSTEM(S):
I. KFF VOLUME 6, CHAPTER 8 AND KFF VOLUME 5, CHAPTER 3, SMOKE VENTILATION AND EXHAUST SYSTEMS: REQUIRED: NO PROVIDED: NO
G. FIRE PROTECTION GENERAL NOTES AND DETAILS:
1) SEE STANDARD DRAWINGS SF001, SF002, SF501 AND OTHER FACILITY DRAWINGS:
**BUILDING CODES AND LIFE SAFETY CODE REQUIREMENTS MEETS OR EXCEEDS KFF REQUIREMENTS**
3. LIFE SAFETY REQUIREMENTS:
1. PROJECT'S APPLIED CODES AND STANDARDS:
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
X:\REVIT PROJECTS\KUWAIT\2023\KU-509974-2 - APACHE ALERT MISSION FACILITIES\K - SUBSTATION\KU-509974-2K-DM-FP-SUBS_RVT25 - A2.rvt
7/14/2026 8:40:29 AM
/1
/2
:4 :2
A
M
GI041
B U
IL
D
IN
G
C O
D E
A N
D L
IF
E
S A
F E
T Y
A N
A L Y
S
IS
A L I A
L S
A L E
M A
B K
U W
A
IT
D F
A B
E R
M M
O O
R E
R D
IP
E
R T
J U
L Y
W E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
A F
R E
E M
A N K
U -5
-2
K -G
I0
S U
B S
T A
T
IO
N
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
IE
S
K
C D
C
F E
C
F E
C
F E
C
FEC
F E
C
F E
C
FEC
FEC
F E
C
F E
C
COMPONENT:
DOOR (D)
STAIRWAY (S)
ACTUAL CLEAR WIDTH
ACTUAL EGRESS
EXIT TYPE:
INTERIOR (INT)
EXTERIOR (EXT)
REQUIRED CLEAR WIDTH
EGRESS CAPACITY
EGRESS CAPACITY TAG
D EXT
0 0
80 100
PORTABLE FIRE EXTINGUISHER IN A CABINET
IN FINISHED AREAS OR BRACKETS (BR)
APPROVED IN UNFINISHED AREAS:
MINIMUM 25 KG ABC TROLLEY FIRE
EXTINGUISHERS (2 - PROVIDED)
TRAVEL DISTANCE: (TD)
OVERALL DIAGONAL DISTANCE: (28.3 M)
ACTUAL OVERALL DIAGONAL DISTANCE TO
MEET ONE HALF REQUIREMENT:
REQUIRED: 15 M PROVIDED: 15.9
FOUR-HOUR RATED ASSEMBLY:
EXIT LIGHT
BR
H.T ROOM
89 m²
FIRE PROTECTION ROOM
9 m²
TRANSFORMER ROOM
79 m²
L.T ROOM
64 m²
GENERATOR SET ROOM
122 m²
BATTERY ROOM
11 m²
B R
TD-A
TD-D
TD-B
TD-C
101B
101C
103C
103E 104B
104A 105A
105B
D EXT
1700 850
5 165
D EXT
850 850
2 165
D EXT
850 850
3 165
D EXT
1700 850
5 165
D EXT
1700 850
3 165
D EXT
1700 850
4 165
D EXT
1700 850
4 165
D EXT
1700 850
3 165
D EXT
1700 850
3 165
D EXT
850 850
3 165
D EXT
850 850
4 165
101A 103A
103D102
BR
BR
B R
B R
B R
B R
B R
B R
D
C
B
A
1 2 3 4 7
A B C D
E
F
5 6
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
GENERAL NOTES
X:\REVIT PROJECTS\KUWAIT\2023\KU-509974-2 - APACHE ALERT MISSION FACILITIES\K - SUBSTATION\KU-509974-2K-DM-FP-SUBS_RVT25.rvt
7/14/2026 8:37:26 AM
/1
/2
:3 :2
A
M
GI101
L
IF
E S
A F
E T
Y P
L A
N
G R
O U
N D
F L O
O R
A
A
A L I A
L S
A L E
M A
B K
U W
A
IT
D F
A B
E R
M M
O O
R E
R D
IP
E
R T
J U
L Y
W E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
A F
R E
E M
A N K
U -5
-2
K -G
I1
S U
B S
T A
T
IO
N
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
IE
S
K
C D
C
0 52.50.5 1.0 1.5 2.0
1:50
LEGEND
1. CONTRACTOR AWARDED THIS PROJECT IS REQUIRED TO
COMPLY WITH KUWAIT REGULATIONS AND ALL OTHER
APPLICABLE CODES, STANDARDS, AND REQUIREMENTS.
2. ALL FIRE AND LIFE SAFETY DRAWING ARE CONCEPTUAL IN
NATURE. CONTRACTOR DESIGN "SHOP" DRAWINGS MUST
COMPLY WITH KUWAIT REQUIREMENTS AND ALL OTHER
APPLICABLE CODES, STANDARDS, AND REQUIREMENTS.
3. FOR GENERAL NOTES, LEGENDS, SYMBOLS, AND
ADDITIONAL OTHER DETAILS SEE STANDARD DRAWINGS
SF001, SF002, SF003, SF501, SF502, AND OTHER FACILITY
DRAWINGS.
4. FOR EXIT AND EMERGENCY LIGHTS DETAILS REFER THE
ELECTRICAL DRAWINGS.
5. PROVIDE FIRE ALARM AND DETECTION SYSTEM FOR THE
FACILITY.
6. PROVIDE PORTABLE FIRE EXTINGUISHERS INTERIOR
HAVING A MINIMUM RATING OF 10B:C. PROVIDE TWO (2)
MINIMUM SIZED 25 KG WHEELED ABC FIRE EXTINGUISHERS
BESIDE DOOR 103C AND DOOR 103E
7. KFF VOL 4, SECTION 1/2 REQUIRES A LICENSE TO STORE
FLAMMABLE LIQUIDS OVER 230 LITERS.
8. SUBSTATION (S/S) A1: DIESEL FUEL CAPACITY: GENERATOR
(GEN) BELLY TANK 1,621 LITERS, ADDITIONAL (ADD)
STORAGE TANK 1,350 LITERS.
9. 9) S/S A2: DIESEL FUEL CAPACITY: GEN #1 BELLY TANK 2,423
LITERS, ADD STORAGE TANK 1,350 LITERS.
GEN #2 BELLY TANK 1,619 LITERS, ADD STORAGE TANK
1,350 LITERS.
10. S/S A3: DIESEL FUEL CAPACITY: GEN #1 BELLY TANK 202
LITERS, ADD STORAGE TANK 1,350 LITERS.
GEN #2 BELLY TANK 2,423L, ADD STORAGE TANK 1,350
LITERS.
1 : 501
LIFE SAFETY PLAN - GROUND FLOOR - A1&A3
MEANS OF EGRESS
FROM ROOM
TRAVEL DISTANCE-TYPE
(CPT, TD, DE)
TRAVEL DISTANCE -
ROUTE (A, B, C, etc.)
ALLOWED MAX TD ACTUAL TRAVEL DISTANCE
H.T ROOM 101 TD A 30000 10427
TRANSFORMER ROOM 103 TD B 30000 7836
L.T ROOM 104 TD C 30000 7851
GENERATOR SET ROOM 105 TD D 30000 10909
OCCUPANT LOAD
ROOM
NUMBER ROOM NAME USE GROUP OLF [SM / PERSON]
OCCUPANT
LOAD
101 H.T. ROOM INDUSTRIAL 28 4
102 FIRE PROTECTION ROOM INDUSTRIAL 28 1
103 TRANSFORMER ROOM INDUSTRIAL 28 3
104 L.T. ROOM INDUSTRIAL 28 3
105 GENERATOR SET ROOM INDUSTRIAL 28 3
106 BATTERY ROOM INDUSTRIAL 28 1
TOTAL OCCUPANT LOAD 15
A B C D
FIRE ZONES
E F G
F E
C
F E
C
F E
C
FEC
F E
C
F E
C
FEC
FEC
F E
C
F E
C
COMPONENT:
DOOR (D)
STAIRWAY (S)
ACTUAL CLEAR WIDTH
ACTUAL EGRESS
EXIT TYPE:
INTERIOR (INT)
EXTERIOR (EXT)
REQUIRED CLEAR WIDTH
EGRESS CAPACITY
EGRESS CAPACITY TAG
D EXT
0 0
80 100
PORTABLE FIRE EXTINGUISHER IN A CABINET
IN FINISHED AREAS OR BRACKETS (BR)
APPROVED IN UNFINISHED AREAS:
MINIMUM 25 KG ABC TROLLEY FIRE
EXTINGUISHERS (2 - PROVIDED)
TRAVEL DISTANCE: (TD)
OVERALL DIAGONAL DISTANCE: (28.3 M)
ACTUAL OVERALL DIAGONAL DISTANCE TO
MEET ONE HALF REQUIREMENT:
REQUIRED: 15 M PROVIDED: 15.9
FOUR-HOUR RATED ASSEMBLY:
EXIT LIGHT
BR
H.T ROOM
89 m²
FIRE PROTECTION ROOM
9 m²
TRANSFORMER ROOM
79 m²
L.T ROOM
64 m²
GENERATOR SET ROOM
95 m²
BATTERYROOM
11 m²
B R
TD-A
TD-D
TD-B
TD-C
101B
101C
103C
103E 104B
104A 105A
D EXT
1700 850
5 165
D EXT
850 850
2 165
D EXT
850 850
3 165
D EXT
1700 850
5 165
D EXT
1700 850
3 165
D EXT
1700 850
4 165
D EXT
1700 850
4 165
D EXT
1700 850
3 165
D EXT
1700 850
3 165
D EXT
850 850
3 165
D EXT
850 850
4 165
101A 103A
103D102
BR
BR
B R
B R
B R
B R
B R
B R
D
C
B
A
1 2 3 4 7
A B C D
E
F
5 6
TANK ROOM
26 m²
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
GENERAL NOTES
X:\REVIT PROJECTS\KUWAIT\2023\KU-509974-2 - APACHE ALERT MISSION FACILITIES\K - SUBSTATION\KU-509974-2K-DM-FP-SUBS_RVT25 - A2.rvt
7/14/2026 8:40:30 AM
/1
/2
:4 :3
A
M
GI102
L
IF
E S
A F
E T
Y P
L A
N
G R
O U
N D
F L O
O R
A
A L I A
L S
A L E
M A
B K
U W
A
IT
D F
A B
E R
M M
O O
R E
R D
IP
E
R T
J U
L Y
W E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
A F
R E
E M
A N K
U -5
-2
K -G
I1
S U
B S
T A
T
IO
N
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
IE
S
K
C D
C
0 52.50.5 1.0 1.5 2.0
1:50
LEGEND
1. CONTRACTOR AWARDED THIS PROJECT IS REQUIRED TO
COMPLY WITH KUWAIT REGULATIONS AND ALL OTHER
APPLICABLE CODES, STANDARDS, AND REQUIREMENTS.
2. ALL FIRE AND LIFE SAFETY DRAWING ARE CONCEPTUAL IN
NATURE. CONTRACTOR DESIGN "SHOP" DRAWINGS MUST
COMPLY WITH KUWAIT REQUIREMENTS AND ALL OTHER
APPLICABLE CODES, STANDARDS, AND REQUIREMENTS.
3. FOR GENERAL NOTES, LEGENDS, SYMBOLS, AND
ADDITIONAL OTHER DETAILS SEE STANDARD DRAWINGS
SF001, SF002, SF003, SF501, SF502, AND OTHER FACILITY
DRAWINGS.
4. FOR EXIT AND EMERGENCY LIGHTS DETAILS REFER THE
ELECTRICAL DRAWINGS.
5. PROVIDE FIRE ALARM AND DETECTION SYSTEM FOR THE
FACILITY.
6. PROVIDE PORTABLE FIRE EXTINGUISHERS INTERIOR
HAVING A MINIMUM RATING OF 10B:C. PROVIDE TWO (2)
MINIMUM SIZED 25 KG WHEELED ABC FIRE EXTINGUISHERS
BESIDE DOOR 103C AND DOOR 103E
7. KFF VOL 4, SECTION 1/2 REQUIRES A LICENSE TO STORE
FLAMMABLE LIQUIDS OVER 230 LITERS.
8. SUBSTATION (S/S) A1: DIESEL FUEL CAPACITY: GENERATOR
(GEN) BELLY TANK 1,621 LITERS, ADDITIONAL (ADD)
STORAGE TANK 1,350 LITERS.
9. 9) S/S A2: DIESEL FUEL CAPACITY: GEN #1 BELLY TANK 2,423
LITERS, ADD STORAGE TANK 1,350 LITERS.
GEN #2 BELLY TANK 1,619 LITERS, ADD STORAGE TANK
1,350 LITERS.
10. S/S A3: DIESEL FUEL CAPACITY: GEN #1 BELLY TANK 202
LITERS, ADD STORAGE TANK 1,350 LITERS.
GEN #2 BELLY TANK 2,423L, ADD STORAGE TANK 1,350
LITERS.
1 : 501
LIFE SAFETY PLAN - GROUND FLOOR - A2
MEANS OF EGRESS
FROM ROOM
TRAVEL DISTANCE-TYPE
(CPT, TD, DE)
TRAVEL DISTANCE -
ROUTE (A, B, C, etc.)
ALLOWED MAX TD ACTUAL TRAVEL DISTANCE
H.T ROOM 101 TD A 30000 10427
TRANSFORMER ROOM 103 TD B 30000 7836
L.T ROOM 104 TD C 30000 7851
GENERATOR SET ROOM 105 TD D 30000 10889
OCCUPANT LOAD
ROOM
NUMBER ROOM NAME USE GROUP OLF [SM / PERSON]
OCCUPANT
LOAD
101 H.T. ROOM INDUSTRIAL 28 4
102 FIRE PROTECTION ROOM INDUSTRIAL 28 1
103 TRANSFORMER ROOM INDUSTRIAL 28 3
104 L.T. ROOM INDUSTRIAL 28 3
105 GENERATOR SET ROOM INDUSTRIAL 28 3
106 BATTERY ROOM INDUSTRIAL 28 1
107 TANK ROOM INDUSTRIAL 28 2
TOTAL OCCUPANT LOAD 17
A B C D
FIRE ZONES
E F
C&C WALL WIND PRESSURE (kPa)
ZONE EFFECTIVE
AREA, M²
POSITIVE
PRESSURE
NEGATIVE
PRESSURE
NOTES
4 1.19 -1.29
1.01 -1.11
0.89 -0.99
-1.58
-1.34
-1.23
1.07 -1.16
0.93
4.65
9.30
46.45
C&C ROOF WIND PRESSURE (kPa)
ZONE POSITIVE
PRESSURE
NEGATIVE
PRESSURE
NOTES
1 0.77 -2.07
0.77
0.77
0.77
-1.75
-1.61
-2.73
-2.32
-2.15
-1.74
-3.72
-2.90
-2.55
1'
1'
1'
1'
EFFECTIVE
AREA, M²
0.93
4.65
9.30
46.45
0.93
4.65
9.30
46.45
0.93
4.65
9.30
46.45
0.93
4.65
9.30
46.45
0.93
4.65
9.30
46.45
0.77
0.77
0.77
0.77
0.77
0.77
0.77
0.77
0.77
0.77
0.77
0.77
C&C PARAPET WIND PRESSURE (kPa)
ZONE EFFECTIVE
AREA, M²
PRESSURE NOTES
CASE A, ZONE2 3.71
2.91
2.35
4.76
3.75
3.34
2.35
3.14
0.93
4.65
9.30
46.45
0.93
4.65
9.30
46.45
CASE A, ZONE3
CASE B, CORNER ZONE
CASE B, INTERIOR ZONE
CASE A, ZONE2
CASE A, ZONE2
CASE A, ZONE2
-2.32
-2.01
-1.93
-1.66
0.93
4.65
9.30
46.45
-2.67
-2.20
-2.07
0.93
4.65
9.30
46.45
CASE A, ZONE3
CASE A, ZONE3
CASE A, ZONE3
CASE B, CORNER ZONE
CASE B, CORNER ZONE
CASE B, CORNER ZONE
CASE B, INTERIOR ZONE
CASE B, INTERIOR ZONE
CASE B, INTERIOR ZONE -1.66
-0.99
-1.30
-1.74
-1.35
-0.64
-0.64
-1.74
1.19
1.01
0.89
1.07
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
/8
/2
:3 :4
P
M
S-001
G E
N E
R A
L N
O T
E S
A L I A
L S
A L E
M A
B K
U W
A
IT
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P H
IL
A
D E
L P
H
IA
D
IS
T R
IC
T
A
R C
H S
T R
E E
T
P H
IL
A
D E
L P
H
IA
P
A
M A
L J U
B O
O R
I
M A
L J U
B O
O R
I
L R
Y A
N
J U
L Y
W
E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5
C C
H A
S T
E N K
U -5
-S
-0
S U
B S
T A
T
IO
N
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
E
S
K
C D
C
GENERAL NOTES
1. REFERENCE STANDARDS:
UFC 1-200-01 DOD BUILDING CODE WITH CHANGE 3, 26 FEBRUARY 2024
UFC 3-301-01 STRUCTURAL ENGINEERING, CHANGE 1, 2 OCTOBER 2023
UFC 3-320-06A CONCRETE FLOOR SLABS ON GRADE SUBJECTED TO HEAVY LOADS, 1 MARCH 2005
IBC 2021 INTERNATIONAL BUILDING CODE, 2018
ASCE 7-16 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
AISC-15TH AMERICAN INSTITUTE OF STEEL CONSTRUCTION - 15TH EDITION
AISC 341-16 SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS
ACI 318-19 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, 2014
TMS 402/602-16 BUILDING CODE REQUIREMENTS AND SPECIFICATION FOR MASONRY STRUCTURES
AWS D1.1 STRUCTURAL WELDING CODE - STEEL, 2015
AWS D1.8 STRUCTURAL WELDING CODE - SEISMIC SUPPLEMENT, 2016
2. DESIGN LOAD CRITERIA:
RISK CATEGORY : IV
ROOF DEAD LOAD: SELF WIEGHT + 3.0kPa ROOF LIVE LOAD: 1.0 kPa MINIMUM CORRIDOR LIVE LOAD - FIRST FLOOR: 4.8 kPa LATRINES: 3.6 kPa MECH/ELEC/COMM: 6.0 kPa STAIRS AND LANDINGS LIVE LOAD: 4.8 kPa SLAB ON GRADE (TYPICAL, UNO) : 4.8 kPa
SNOW LOAD: N/A
SEISMIC LOAD:
SITE CLASS: C
IMPORTANT FACTOR, Ie: 1.5
SPECTRAL RESPONSE ACCELERATIONS:
SHORT PERIOD, Ss: 0.410g ONE SECOND PERIOD, S1: 0.110g
DESIGN SPECTRAL RESPONSE ACCELERATIONS:
SHORT PERIOD, SDS: 0.355g ONE SECOND PERIOD, SD1: 0.110g
SEISMIC DESIGN CATEGORY: D
SEISMIC ANALYTICAL PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE
LATERAL FORCE RESISTING SYSTEM : SPECIAL REINFORCED MOMENT FRAME
RESPONSE MODIFICATION FACTOR, R: 8.0
SYSTEM OVERSTRENGTH FACTOR: 3.0
DEFLECTION AMPLIFICATION FACTOR, Cd: 5.5 SEISMIC RESPONSE COEFFICIENT, Cs: 0.067
DESIGN BASESHEAR, V: 0.067W (W = SEISMIC WEIGHT)
WIND LOAD:
BASIC WIND SPEED, V: 174 KPH
EXPOSURE CATEGORY: C
IMPORTANT FACTOR, Iw: 1.00 INTERNAL PRESSURE COEFFICIENT, GCpi: +/-0.18 TOPOGRAPHIC FACTOR, Kzt: 1.0 DIRECTIONALITY FACTOR, Kd: 0.85
FOUNDATION DESIGN CRITERIA:
SEE SS001 FOR ADDITIONAL INFORMATION.
A. FOUNDATION DESIGN IS BASED UPON THE FOLLOWING SOIL PARAMETERS:
1. NET ALLOWABLE SOIL BEARING PRESSURE
A. CONTINUOUS FOOTING 144 KPa B. ISOLATED FOOTING 168 KPa
B. LATERAL EARTH PRESSURE PARAMETERS:
1. SOIL DENSITY (MOIST) 19.6 kN/m3
2. COEFFICIENT OF ACTIVE PRESSURE (Ka) = 0.31
3. COEFFICIENT OF AT-REST PRESSURE (Ko) = 0.47
4. COEFFICIENT OF PASSIVE EARTH PRESSURE (Kp) = 3.25
5. ANGLE OF INTERNAL FRICTION (phi) = 32 DEGREES
6. COEFFICIENT OF FRICTION (µ) = 0.40
7. MODULUS OF SUB-GRADE REACTION (Ks) FOR SOG = 54 MN/m³
NOTES:
1. ALL EXTERIOR WALLS, WINDOWS, DOORS, MECH. LOUVERS, ROOFING COMPONENTS, AND ALL OTHER ASSEMBLIES OR OPENINGS WITHIN THE BUILDING
ENVELOPE SHALL BE DESIGNED FOR THE C&C DESIGN WIND PRESSURES AS SHOWN BY ZONE.
2. LOCATION OF ZONES IS PROVIDED PER ASCE7-16, FIG. 30.3-1 & 30.3-2
3. DISTANCE (a) = 1630mm, 0.2h = 1240mm, AND 0.6h = 3720mm
4. THE CONTRACTOR SHALL USE COMPONENT AND CLADDING WIND PRESSURE TO DESIGN ALL ELEMENTS ATTACHED TO THE BUILDING.
5. FOR C&C PARAPET WIND PRESSURES; LOAD CASE A AND B ARE WINDWARD AND LEEWARD PRESSURES, RESPECTIVELY.
1 2 3 4 6 7
C
B
A
CF3
CF3
CF1
CF1CF1
CF1
CC1 CC1
CC1
CC1
CC1
CC1
CC1CC1
GB3
G B
6400 5300 4300 2800 3375
24700
400 1690
1710 4245
SF501
TYP
SF501
TYP
SF501
TYP
SF501
TYP
SF301
SF301
SF301
SF301
CF2 CF2 CF2
CF3
CF2
CF2
CF2
CF2
CF2
CF2
CF2
CF2 CF3CF2
CC2 CC2 CC2
CC2
CC2
CC2
CC2
CC2
CC2
CC2
CC2CC2CC2
CC2
CC2
CC2
1 TYP
SF502
1. REFER TO GENERAL NOTES SHEET SS-001 AND SS-002
FOR ADDITIONAL STRUCTURAL NOTES AND FOUNDATION
REQUIREMENTS.
2. ELEVATION 0.00 EQUATES TO FINSHIED FLOOR
ELEVATION (FFE) ARCH. ALL ELEVATIONS ARE
REFERENCED FROM ELEVATION 0.00
3. BOTTOM OF FOOTING ELEVATION = -1500MM U.O.N, TYP.
SEE SF501 FOR SPECIFICS (TYP UNO).
4. ELEVATION OF BOTTOM OF TRENCH = -1105MM U.O.N,
TYP.
5. SEE SHEET SF601 FOR FOUNDATION, COLUMNS AND
GRADE BEAMS SCHEDULES.
ELETRICAL TRENCH, SEE ELEC AND ARCH DRAWINGS FOR
DETAILS.
1.
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
SHEET KEY NOTES
GENERAL NOTES
/8
/2
:3 :4
P
M
SB101
F O
U N
D A
T
IO
N P
L A
N
A L I A
L S
A L E
M A
B K
U W
A
IT
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P H
IL
A
D E
L P
H
IA
D
IS
T R
IC
T
A
R C
H S
T R
E E
T
P H
IL
A
D E
L P
H
IA
P
A
M A
L J U
B O
O R
I
M A
L J U
B O
O R
I
L R
Y A
N
J U
L Y
W
E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5
C C
H A
S T
E N K
U -5
-S
B
S U
B S
T A
T
IO
N
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
E
S
K
C D
C
0 7.54 5.521 3
1:75
1 : 751
FOUNDATION PLAN
25300
D
C
B
A
6400 5300 4300 2800 3375 2525
GB3GB4 GB2
GB1
GB3
GB4 GB3 GB2 GB1 GB3
G B
G
B
G B
G B
G
B
G B
SF501
TYP
G B
G B
G
B
G B
SF501
TYP
SF501
TYP
SF301
SF301
SF301
SF301
TYP
TYP
TYP
5 TYP
5 TYP
SF502
TYP
SF502
TYP
6 TYP
9 TYP
SF502
25700
8 77
10TYP 11
5300 4300
4750 5300 4375
SF508
TYP
1. REFER TO GENERAL NOTES SHEET SS-001 AND SS-002
FOR ADDITIONAL STRUCTURAL NOTES AND FOUNDATION
REQUIREMENTS.
2. ELEVATION 0.00 EQUATES TO FINSHIED FLOOR
ELEVATION (FFE) ARCH. ALL ELEVATIONS ARE
REFERENCED FROM ELEVATION 0.00
3. TOP OF SOG ELEVATION = 00.00MM U.O.N, TYP. SEE
SF501 FOR SPECIFICS (TYP UNO).
4. SEE SHEET SF601 FOR FOUNDATION, COLUMNS AND
GRADE BEAMS SCHEDULES.
5. SLAB-ON-GRADE JOINTS SPACING SHALL NOT EXCEED
4000MM O/C IN BOTH DIRECTIONS. REFER TO SF501,
SF502 FOR CONTROL JOINTS DETAILS AND 1/SS502 FOR
TYPICAL CONSTRUCTION JOINT . NOTE CONSTRUCTION
JOINTS SHALL BE PROVIDED IN BOTH DIRECTIONS.
6. COORDINATE WITH ARCHITECTURAL, MECHANICAL,
PLUMBING, FIRE PROTECTION, AND ELECTRICAL
DRAWINGS FOR LOCATIONS AND SIZES OF FLOOT
OPENINGS, FLOOR DRAIN, AND PENETRATION AND ALL
EQUIPMENT PROVIDED.
ELETRICAL TRENCH, SEE ELEC AND ARCH DRAWINGS FOR
DETAILS.
250MM CONCRETE SLAB ON GRADE W/ D16 AT 250MM O/C
EW PLACED AT TOP THIRD OF SLAB THICKNESS.
CMU WALL, SEE SF507 FOR SPECIFICS
STEEL GRATING TYPE W-15-4 (89X9.5)
SLAB-ON-GRADE JOINTS, TYP.
PROVIDE GB5 AT ALL LOCATIONS WHERE CMU WALL
BUILT OVER ELECTRICAL TRENCH.
200MM CONCRETE SLAB. SEE DETAILS 1B/SS501 FOR
SPECIFICS. SEE ARCH FOR DIMENSIONS AND SLOPE.
200MM CONCRETE SLAB. SEE DETAILS 1A/SS501 FOR
SPECIFICS. SEE ARCH FOR DIMENSIONS AND SLOPE.
CONCRETE COLUMN TYPE, CC1.
150MM X 900MM LG BOLLARD, SEE DETAIL 2/SS501.
MECHANICAL EQUIPMENT PAD W/ D16 AT 250 TOP AND
BOTTOM, SEE DETAIL 2/SS510. REFER TO MECH
DRAWINGS FOR EQUIPMENT SIZE.
EQUIPMENT PAD, SEE DETAIL 3/SF508. REFER TO
ELEC/ARCH FOR EQUIPMENT SIZE.
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
SHEET KEY NOTES
GENERAL NOTES
/8
/2
:3 :4
P
M
SF101
F R
A M
IN
G
P L
A N
G
R O
U N
D F
L O
O R
A L I A
L S
A L E
M A
B K
U W
A
IT
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P H
IL
A
D E
L P
H
IA
D
IS
T R
IC
T
A
R C
H S
T R
E E
T
P H
IL
A
D E
L P
H
IA
P
A
M A
L J U
B O
O R
I
M A
L J U
B O
O R
I
L R
Y A
N
J U
L Y
W
E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5
C C
H A
S T
E N K
U -5
-S
F
S U
B S
T A
T
IO
N
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
E
S
K
C D
C
1 : 751
FLOOR PLAN - GROUND FLOOR
0 7.54 5.521 3
1:75
D
C
B
A
5300 4300 2800 3375
C B
C
B
C B
C B
C B
C B
C B
C B
CB1
CB1
CB1
CB1
CB1
CB1
CB1 CB2
CB1CB1
CB1CB1
CB2
CB1CB1 CB2
CB1
CB1
CB1
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C B
C
B
C B
C B
C B
C B
C B
C B
C B
C B
C
B
C B
C
B
C B
C
B
C B
C
B
C B
C
B
24700
T Y
P T
Y P
T Y
P
SF501
TYP
SF502
TYP
SF301
SF301
SF301
SF301
SF502
TYP
TYP
TYP
1. REFER TO STRUCTURAL STANDARD DETAILS AND NOTES
ON SHEETS SS001 AND SS002 FOR ADDITIONAL
STRUCTURAL NOTES AND FOUNDATION REQUIREMENTS.
2. COORDINATE WITH ARCHITECTURAL, MECHANICAL,
PLUMBING, FIRE PROTECTION, AND ELECTRICAL
DRAWINGS FOR LOCATIONS AND SIZES OF OPENINGS,
FLOOR DRAIN, AND PENETRATION AND ALL EQUIPMENT
PROVIDED.
ONE-WAY CONCRETE SLAB CS1, SEE S-601 FOR
SPECIFICS.
150MM CONCRETE CURB. SEE SF501 FOR SPECIFICS. SEE
MECH AND ARCH FOR DETAILS.
200MM CONCRETE PARAPET. SEE SF502 FOR DETAILS
ROOF HATCH, SEE ARCH AND MECH FOR SIZE AND
SPECIFICS. REFER TO STANDARD DETAILS FOR
REINFORCEMENT AROUND HATCH OPENING.
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
SHEET KEY NOTES
GENERAL NOTES
/8
/2
:3 :4
P
M
SF102
F R
A M
IN
G
P L
A N
R
O O
F
A L I A
L S
A L E
M A
B K
U W
A
IT
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P H
IL
A
D E
L P
H
IA
D
IS
T R
IC
T
A
R C
H S
T R
E E
T
P H
IL
A
D E
L P
H
IA
P
A
M A
L J U
B O
O R
I
M A
L J U
B O
O R
I
L R
Y A
N
J U
L Y
W
E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5
C C
H A
S T
E N K
U -5
-S
F
S U
B S
T A
T
IO
N
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
E
S
K
C D
C
1 : 751
FRAMING PLAN - ROOF
0 7.54 5.521 3
1:75
01_LEVEL_FF
F2
TOP OF PARAPET
GROUND LEVEL
LEVEL_TOF
-1500
DCBA
CONCRETE SLAB, SEE PLANS
CONCRETE FRAMING,
SEE PLANS, TYP
CONCRETE SLAB ON
GRADE, SEE PLANS
CONCRETE FOUNDATION,
SEE PLANS
T.O. SLAB
SF502
TYP
CONCRETE GRADE
BEAM ABOVE TRENCH,
SEE DETAILS
AND
/2 SF502
/4 SF508
01_LEVEL_FF
123467
F2
TOP OF PARAPET
GROUND LEVEL
LEVEL_TOF
-1500
ROOF
CONCRETE SLAB, SEE PLANS
CONCRETE FRAMING,
SEE PLANS, TYP
CONCRETE SLAB ON
GRADE, SEE PLANS
CONCRETE FOUNDATION,
SEE PLANS
CONCRETE SLAB,
SEE PLANS
T.O. SLAB
SF502
TYP
CMU PARTITION
WALL,TYP
6000 6000
CONCRETE CURB,
SEE PLANS AND
MECH.
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
/8
/2
:3 :4
P
M
SF301
F L
O O
R F
R A
M
IN
G S
E C
T
IO
N S
A L I A
L S
A L E
M A
B K
U W
A
IT
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P H
IL
A
D E
L P
H
IA
D
IS
T R
IC
T
A
R C
H S
T R
E E
T
P H
IL
A
D E
L P
H
IA
P
A
M A
L J U
B O
O R
I
M A
L J U
B O
O R
I
L R
Y A
N
J U
L Y
W
E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5
C C
H A
S T
E N K
U -5
-S
F
S U
B S
T A
T
IO
N
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
E
S
K
C D
C
1 : 501
TRANSVERSE SECTION
1 : 502
LONGITUDINAL SECTION
0 52.50.5 1.0 1.5 2.0
1:50
GL
R E
F E
R T
O P
L A
N
REFER TO PLAN
CONCRETE COLUMN, (REFER TO PLAN
AND SCHEDULES FOR SPECIFICS)
12MM EXPANSION MATERIAL AT COULMN
CONCRETE SLAB ON GRADE, (REFER TO
PLAN FOR SPECIFICS)
CONCRETE FOOTING, (REFER
TO SCHEDULES FOR SIZE
AND REINFORCEMENT.)
T/SOG
REFER TO PLAN
GL
TOF
REFER TO PLAN
T/GRADE BEAM
REFER TO PLAN
CONCRETE GRADE BEAM,
(REFER TO SCHEDULES FOR
SIZE AND REINFORCEMENT)
A
A-A
VAPOR RETARDER ON 100MM
CAPILLARY WATER BARRIER
"T
"2 T
/3
GRADE BEAM REINFORCEMENT, TOP
AND BOTTOM, (REFER TO
SCHEDULES FOR SPECIFICS) SLAB ON GRADE REIFORCEMENT,
(REFER TO PLAN FOR SPECIFICS)
(3) - D13 REBARS
D13 REBARS AT 300" OC
A
VAPOR BARRIER ,
TYP
100MM CAPILLARY WATER
BARRIER OVER COMPACTED
SOIL, TYP
ROUGHEN SURFACE TO 6MM
AMPLITUDE
GRADE BEAM STIRRUPS AT GRADE
BEAM - COLUMN JOINT W/ STD 135°
BEND AT ENDS TO MATCH SPACING
OF GRADE BEAM STIRRUPS
SPACING.
50MM BLINDING CONCRETE, TYP
"SEE ARCH"
GL
R E
F E
R T
O P
L A
N
REFER TO PLAN
CONCRETE COLUMN, (REFER TO PLAN
AND SCHEDULES FOR SPECIFICS)
12MM EXPANSION
MATERIAL AT COULMN
CONCRETE SLAB ON GRADE, (REFER
TO PLAN FOR SPECIFICS)
T/SOG
REFER TO PLAN
TOF
REFER TO PLAN
VAPOR RETARDER
SLAB ON GRADE REIFORCEMENT,
(REFER TO PLAN FOR SPECIFICS)
150X150X50 SHEAR KEY INSTALLED
AT THE CENETER OF COLUMN
"S E
E P
L A
N S
"T
CONCRETE BLOCKOUT
100MM CAPILLARY WATER
BARRIER OVER COMPACTED
SOIL, TYP
50MM BLINDING CONCRETE, TYP
GL
12MM EXPANSION FELT BETWEEN
GRADE BEAM AND SLAB EDGE
CONCRETE SLAB ON GRADE,
(REFER TO PLAN FOR
SPECIFICS
CONCRETE GRADE BEAM ,
(REFER TO SCHEDULE FOR
SIZE AND REINFORCEMENT)
T/SOG
REFER TO PLAN
VAPOR RETARDER, TYP
S E
E P
L A
N S
"T
"2 T
/3
S P
L
IC
E
C L A
S S
B T
E N
S
IO
N
200MM CMU WALL , (REFER TO
SCHEDULE FOR SPECIFICS)
D16 DOWEL BARS AT 600MM
O/C
BOND BEAM, (REFER TO
SCHEDULES)
100MM CAPILLARY WATER
BARRIER OVER COMPACTED SOIL,
TYP
"SEE ARCH"
100MM VENEER WALL ,
(REFER TO ARCH)
13MM EXPANSION MATERIALS
AT COULMN, (TYP)
CONCRETE GRADE BEAM ,
(REFER TO SCHEUDLES
FOR SPECIFICS)
CONCRETE COLUMN PER
PLAN
CONTROL JOINT, (REFER TO
TYPICAL DETAILS FOR SPECIFICS)
CJ
CJ
CJ
CJ
(2) - D13X1500 PLACED AS
SHOWN AND LOCATED AT
SLAB MID-HEIGHT, TYP.
"TYP"
VAPOR RETARDER
100MM APILLARY WATER BARRIER
OVER COMPACTED SOIL, TYP
CONCRETE SLAB ON GRADE,
SEE PLANS, TYP
150MM CONCRETE WALL W/ D13 AT
150MM O/C., TYP
200MM CONCRETE SLAB W/ D13 AT
150MM O/C., TYP
50MM CONCRETE BLINDING,
TYP
150MM (MIN) WATER STOP, TYP
D10 DOWELS TO MATCH
VERTICAL REINFORCEMENT
D13 AT 500 O/C, TYP
"M
IN
L102X76X6.4XCONT. W/ -
20ØX150MM HWS AT 400MM
O/C, TYP
STEEL GRATING TYPE W-15-4
(89X9.5)
"TYP"
ROUGHEN SURFACE TO
6MM AMPLITUDE, TYP
TRENCH BASE REINFORCEMENT
SEE , PROVIDE FULL
DEVELOPMENT LENGTH OR 90° STD
HOOK INTO COLUMN FOOTING, TYP
/2 SF501
TRENCH BASE REINFORCEMENT SEE
, PROVIDE FULL
DEVELOPMENT LENGTH OR 90° STD
HOOK INTO COLUMN FOOTING, TYP
/2 SF501
CONCRETE COLUMN, REINFORCEMENT
NOT SHOWN FOR CLARITY. REFER TO
SCHEDULES FOR SPECIFICS, TYP
CONCRETE FOUNDATION, REFER TO
SCHEDULES FOR SPECIFICS, TYP
VAPOR RETARDER ON 100MM
CAPILLARY WATER BARRIER OVER
COMPACTED SOIL, TYP
"MIN"
150MM (MIN) WATERSTOP, TYP
ROOFING MATERIALS, SEE
ARCH, TYP
CONCRETE SLAB, SEE PLANS
AND SCHEDULES, TYP
"TYP"
"M A
X
(1) - D10XCONT. TOP AND
BOTTOM OF CURB, PROVIDE
90° STD HOOK AT ENDS, TYP
D10 AT 150MM O/C, PROVIDE
180° STD HOOK AT TOP OF
CURB AND 90° STD HOOK
INTO SLAB, TYP
"S E
E A
R C
H
NOTE:
CONNECTION OF MECH EQUIPMENT TO CONCRETE
CURB SHALL BE DESIGNED BY SUPPLIER
ROUGHEN SURFACE TO
6MM AMPLITUDE
0 0.2 10.4 0.6 0.8 2
1:20 0 2.51.00.5 1.5
1:25
1 : 207
TYPICAL EXTERIOR COLUMN DETAIL
1 : 203
TYPICAL INTERIOR COLUMN DETAIL
NTS6
SECTION AT GRADE BEAM
1 : 254
PLAN VIEW AT BUILDING COLUMN
1 : 202
TYPICAL ELECTRICAL TRENCH DETAIL
1 : 205
BASE OF TRENCH TO FOUNDATION DETAIL
1 : 101
MECH CURB DETAIL
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
/8
/2
:3 :4
P
M
SF501
S T
R U
C T
U R
A L
D E
T A
IL
S
A L I A
L S
A L E
M A
B K
U W
A
IT
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P H
IL
A
D E
L P
H
IA
D
IS
T R
IC
T
A
R C
H S
T R
E E
T
P H
IL
A
D E
L P
H
IA
P
A
M A
L J U
B O
O R
I
M A
L J U
B O
O R
I
L R
Y A
N
J U
L Y
W
E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5
C C
H A
S T
E N K
U -5
-S
F
S U
B S
T A
T
IO
N
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
E
S
K
C D
C
0 10.50.1 0.2 0.3 0.4
1:10
"TYP"
"CLR"
"T Y
P
"C L R
SLAB REINFORCEMENT, SEE
PLAN AND SCHEDULES, TYP
BEAM REINFORCEMENT, SEE
PLAN AND SCHEDULES, TYP
D13 AT 250 O/C, EF, TYP
20MM CHAMFER, TYP
T/ PARAPET
T/ SLAB
SEE PLAN
ROUGHENED SURFACE TO FULL
AMPLITUDE OF 6MM (MIN), TYP
(3) - D13xCONT.
BOND BEAM, REFER TO SCHEDULES
FOR SPECIFICS, (TYP)
CONCRETE SOG, (REFER TO
PLAN FOR SPECIFICS)
200MM CMU WALL, REFER TO
SCHEDULES FOR SPECIFICS
T/SOG
(REFER TO PLAN)
DOWELS W/ 90° TO MATCH
VERTICAL REINFORCEMENT
(TYP)
STD LAP
D13 AT 250 OC
M A
S O
N R
Y N
O T
E S
L A
P S
P L
IC
E
P E
R
BOND BEAM, REFER TO SCHEDULES
FOR SPECIFICS, (TYP)
200MM CMU WALL, REFER TO
SCHEDULES FOR SPECIFICS
T/SOG
(REFER TO PLAN)
DOWELS W/ 90° TO MATCH
VERTICAL REINFORCEMENT
CONCRETE GRADE BEAM,
SEE SCHEDULES AND 1/SF301
"M
IN
D O
W E
L E
M B
E D
R E
F E
R T
O P
L A
N
"T
T Y
P
T /3
SLAB REINFORCEMENT,
(REFER TO PLAN)
BACKER ROD OR
SEALANT AS REQUIRED,
(REFER TO ARCH)
"T Y
P
"T Y
P
G
A P
NOTE:
SLAB, BEAMS, AND WALL
REINFORCEMENT NOT SHOWN FOR
CLARITY
CONCRETE SLAB, REFER
TO PLAN FOR SPECIFICS
CONCRETE BEAM, REFER
TO SCHEDULES
CONCRETE PARAPET, REFER
TO PLAN FOR SPECIFCS.
L203X203X12.7XCONT. ANGLE W/
13MMØX75MM EXPANSION ANCHOR AT
600MM O/C (MAX) INTO CONCRETE BEAM
AND 16MMØX100 EXPANSION ANCHOR AT
600MM INTO CMU WALL AND VERTICAL
LONG-SLOTTED HOLE. INSTALL ANCHOR
AT BOTTOM OF LONG-SLOTTED HOLE. CMU WALL, TYP.
25MM COMPRESSIBLE JOINT
MATERIALS, TYP
L203X152X12.7XCONT.
BRICK RELIEF ANGLE W/
13MMØ EXPANSION
ANCHOR AT 400MM O/C
(MAX) INTO CONCRETE
BEAM.
"T Y
P
G
A P
NOTE:
SLAB, BEAMS, AND WALL
REINFORCEMENT NOT SHOWN FOR
CLARITY
CONCRETE SLAB, REFER
TO PLAN FOR SPECIFICS
CONCRETE BEAM, REFER
TO SCHEDULES
L203X203X12.7XCONT. ANGLE W/ 13MMØX75MM
EXPANSION ANCHOR AT 600MM O/C (MAX) INTO
CONCRETE BEAM AND 16MMØ AT 600MM
THRUBOLT INTO CMU WALL AND VERTICAL
LONG-SLOTTED HOLE. INSTALL ANCHOR AT
BOTTOM OF LONG-SLOTTED HOLE.
CMU WALL, TYP.
25MM COMPRESSIBLE JOINT
MATERIALS, TYP
NOTE:
SLAB AND WALL REINFORCEMENT
NOT SHOWN FOR CLARITY
CONCRETE SLAB, REFER TO PLAN
FOR SPECIFICS
L203X203X12.7XCONT. ANGLE W/
13MMØX75MM EXPANSION ANCHOR AT
600MM O/C (MAX) INTO CONCRETE BEAM
AND 16MMØ AT 600MM THRUBOLT INTO
CMU WALL AND VERTICAL LONG-
SLOTTED HOLE. INSTALL ANCHOR AT
BOTTOM OF LONG-SLOTTED HOLE. CMU WALL, TYP.
25MM COMPRESSIBLE JOINT
MATERIALS, TYP
"TYP"
25(4) - D13 HANGER
REINFORCEMENT, TYP
NOTE:
OTHER GIRDER TRANSVERSE
REINFORCEMENT NOT SHOWN FOR
CLARITY.
CONCRETE
GIRDER, SEE
PLANS AND
SCHEDULES, TYP
CONCRETE BEAM, SEE
PLANS AND SCHEDULES, TYP
EXTERIOR VENEER, SEE ARCH
200MM CMU WALL , (REFER TO
SCHEDULE FOR SPECIFICS)
BOND BEAM, (REFER TO
SCHEDULES)
CONCRETE GRADE BEAM,
(REFER TO SCHEDULES)
TRENCH WALL, SEE
/2 SF501
D13 AT 400 O/C, TYP. 400
GL
"SEE ARCH"
(1) - D16 TOP AND
BOTTOM
1 : 208
TYPICAL PARAPET DETAIL
0 0.2 10.4 0.6 0.8 2
1:20
1 : 105
INTERIOR CMU WALL BEARING ON SOG
1 : 102
INTERIOR CMU WALL BEARING ON BEAM
1 : 106
TYPICAL SOG CONTROL JOINT
1 : 2038
EXTERIOR CMU WALL BRACING
1 : 201
INTERIOR CMU WALL BRACING TO
CONCRETE BEAM
1 : 207
INTERIOR CMU WALL BRACING TO
CONCRETE SLAB
1 : 204
BEAM-GIRDER DETAIL
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
/8
/2
:3 :4
P
M
SF502
S T
R U
C T
U R
A L
D E
T A
IL
S
A L I A
L S
A L E
M A
B K
U W
A
IT
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P H
IL
A
D E
L P
H
IA
D
IS
T R
IC
T
A
R C
H S
T R
E E
T
P H
IL
A
D E
L P
H
IA
P
A
M A
L J U
B O
O R
I
M A
L J U
B O
O R
I
L R
Y A
N
J U
L Y
W
E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5
C C
H A
S T
E N K
U -5
-S
F
S U
B S
T A
T
IO
N
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
E
S
K
C D
C
0 10.50.1 0.2 0.3 0.4
1:10
1 : 203
GRADE BEAM TO SOG DETAIL
AT 2H
"A"
AT 2H
"A"
LAP SPLICE CLASS B
"SP""R1" "R1" "B"
AT 2H
"C" "R2"
AT 2H
"C"
LAP SPLICE CLASS B
AT 2H
"D"
AT 2H
"D""SP""R3" "R3"
AT 2H
"E" "R4"
AT 2H
"E"
"TYP"
"SS"
BEAM DETAIL NOTES:
1. THIS DETAIL IS APPLICABLE CONCRETE BEAMS CB1 - CB4.
2. ALL DIMENSIONS ARE IN MM, UNO.
3. ALL STIRRUPS START 50MM FROM FACE OF SUPPORTS (SS = 50MM), UNO.
4. ALL SPLICES SHALL BE CLASS B SPLICE. SHOWN SPLICE LOCATIONS ARE OPTIONAL. NO SPLICE PERMITTED AT JOINTS.
CONTRACTOR CAN SUGGEST DIFFERENT SPLICE LOCATIONS. NO SPLICE PERMITTED WITHIN 2H FROM FACE OF SUPPORT.
5. PROVIDE 90° STD HOOK AT BEAM ENDS, TYP.
6. COLUMN REIFORCEMENT NOT SHOWN FOR CLARITY.
7. CHAMFERS ARE 20MM (MIN), TYP.
B
B
A
A
H
7 5 4 3 2 1
DESIGNATION SIZE NO. OF LEGS SPACING
A D13 2 110
B D13 4 110
C D13 2 110
D D13 2 110
E D13 2 110
R1 D13 2 185
R2 D13 2 145
R3 D13 2 175
R4 D13 2 160
INTERIOR BEAM STIRRUPS DISTRIBUTION - LONG.
SP D13 2 110
DESIGNATION SIZE NO. OF LEGS SPACING
A D13 2 110
B D13 4 110
C D13 2 110
D D13 2 110
E D13 2 110
R1 D13 2 250
R2 D13 2 185
R3 D13 2 225
R4 D13 2 245
PERIMETER BEAM STIRRUPS DISTRIBUTION - LONG.
SP D13 2 110
A-A B-B
TOP & BOTTOM
REINFORCEMENT, SEE
SCHEDULES
TOP & BOTTOM
REINFORCEMENT, SEE
SCHEDULES
STIRRUPS
REINFORCEMENT
T Y
P "C
L R
TYP
"CLR"
AT 2H
"F"
AT 2H
"F"
AT 2H
"J"
AT 2H
"J"
"TYP"
"SS"
BEAM DETAIL NOTES:
1. THIS DETAIL IS APPLICABLE CONCRETE BEAMS CB1 - CB4.
2. ALL DIMENSIONS ARE IN MM, UNO.
3. ALL STIRRUPS START 50MM FROM FACE OF SUPPORTS (SS = 50MM), UNO.
4. ALL SPLICES SHALL BE CLASS B SPLICE. SHOWN SPLICE LOCATIONS ARE OPTIONAL. NO SPLICE PERMITTED AT JOINTS. CONTRACTOR CAN
SUGGEST DIFFERENT SPLICE LOCATIONS. NO SPLICE PERMITTED WITHIN 2H FROM FACE OF SUPPORT.
5. PROVIDE 90° STD HOOK AT BEAM ENDS, TYP.
6. COLUMN REIFORCEMENT NOT SHOWN FOR CLARITY.
7. CHAMFERS ARE 20MM (MIN), TYP.
A
A
H
"G" "R6" "SP" "R6" "G" "R7""R5"
A B C D
A-A
TOP & BOTTOM
REINFORCEMENT, SEE
SCHEDULES
STIRRUPS
REINFORCEMENT
TYP
"CLR"
DESIGNATION SIZE NO. OF LEGS SPACING
F D13 2 110
G D13 2 110
J D13 2 110
R5 D13 2 200
R6 D13 2 230
R7 D13 2 230
INTERIOR BEAM STIRRUPS DISTRIBUTION - TRANSV.
SP D13 2 110
DESIGNATION SIZE NO. OF LEGS SPACING
F D13 2 110
G D13 2 110
J D13 2 110
R5 D13 2 210
R6 D13 2 250
R7 D13 2 250
PERIMETER BEAM STIRRUPS DISTRIBUTION - TRANSV.
SP D13 2 110
NTS2
LONGITUDINAL SMF BEAM DETAILS
NTS1
TRANSVERSE SMF BEAM DETAILS
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
/8
/2
:3 :4
P
M
SF503
S M
F B
E A
M S
D E
T A
IL
S
A L I A
L S
A L E
M A
B K
U W
A
IT
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P H
IL
A
D E
L P
H
IA
D
IS
T R
IC
T
A
R C
H S
T R
E E
T
P H
IL
A
D E
L P
H
IA
P
A
M A
L J U
B O
O R
I
M A
L J U
B O
O R
I
L R
Y A
N
J U
L Y
W
E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5
C C
H A
S T
E N K
U -5
-S
F
S U
B S
T A
T
IO
N
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
E
S
K
C
COLUMN DETAIL NOTES:
1. THIS DETAIL IS APPLICABLE ALL CONCRETE
COLUMNS.
2. ALL DIMENSIONS ARE IN MM, UNO.
3. ALL SPLICES SHALL BE CLASS B TENSION SPLICE.
NO SPLICE PERMITTED AT JOINTS. SPLICE SHALL
BE PROVIDED AT CENTER HALF OF COLUMNS.
4. PROVIDE 90° STD HOOK AT COLUMN ENDS, TYP.
5. BEAMS AND SLAB REINFORCEMENT NOT SHOWN
FOR CLARITY.
6. CHAMFERS ARE 20MM (MIN), TYP.
A A
GL
D A
T
O
/C D
A
T
O
/C
D A
T
O
/C
A T
C L A
S S
B T
E N
S
IO
N S
P L
IC
E D
A
T
O
/C
D A
T
O
/C
S E
E S
C H
E D
U L E
S B
E A
M H
E
IG
H T
S E
E S
C H
E D
U L E
S B
E A
M H
E
IG
H T
A A
GL
D A
T
O
/C D
A
T
O
/C
S E
E S
C H
E D
U L E
S B
E A
M H
E
IG
H T
EXTERIOR COLUMN INTERIOR COLUMN
D A
T
O
/C
A T
C L A
S S
B T
E N
S
IO
N S
P L
IC
E
D A
T
O
/C D
A
T
O
/C
T/ SLAB
SEE PLAN
T/ SLAB
SEE PLAN
T/ SLAB
SEE PLAN
T/ FND
SEE PLAN
T/ FND
SEE PLAN
6 (MIN)
A-A
COLUMN
RIENFORCEMENT,
SEE SCHEDULES
COLUMN TIES, SEE
SCHEDULE
T Y
P "C
L R
TYP
"CLR"
1 : 201
TYPICAL CONCRETE SMF COLUMN
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
/8
/2
:3 :4
P
M
SF504
S M
F C
O L
U M
N D
E T
A
IL
S
A L I A
L S
A L E
M A
B K
U W
A
IT
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P H
IL
A
D E
L P
H
IA
D
IS
T R
IC
T
A
R C
H S
T R
E E
T
P H
IL
A
D E
L P
H
IA
P
A
M A
L J U
B O
O R
I
M A
L J U
B O
O R
I
L R
Y A
N
J U
L Y
W
E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5
C C
H A
S T
E N K
U -5
-S
F
S U
B S
T A
T
IO
N
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
E
S
K
C D
C
0 0.2 10.4 0.6 0.8 2
1:20
"TYP"
BEAM DETAIL NOTES:
1. THIS DETAIL IS APPLICABLE CONCRETE BEAMS CB5 - CBX.
2. ALL DIMENSIONS ARE IN MM, UNO.
3. ALL STIRRUPS START 50MM FROM FACE OF SUPPORTS, UNO.
4. ALL SPLICES SHALL BE CLASS B SPLICE. SHOWN SPLICE LOCATIONS ARE OPTIONAL. NO SPLICE PERMITTED AT JOINTS. CONTRACTOR CAN
SUGGEST DIFFERENT SPLICE LOCATIONS.
5. PROVIDE 90° STD HOOK AT BEAM ENDS, TYP.
6. CHAMFERS ARE 20MM (MIN), TYP.
A
A H
"STIRRUPS PER CONCRETE BEAM SCHEDULE ON SF601"
A B C D
"STIRRUPS PER CONCRETE BEAM SCHEDULE ON SF601" "STIRRUPS PER CONCRETE BEAM SCHEDULE ON SF601"
"TYP"
"CLASS B SPLICE"
"TYP"
"CLASS B SPLICE"
A-A
TOP & BOTTOM
REINFORCEMENT, SEE
SCHEDULES
STIRRUPS
REINFORCEMENT
TYP
"CLR"
SLAB DETAIL NOTES:
1. THIS DETAIL IS APPLICABLE ALL CONCRETE SLABS, UNO.
2. ALL DIMENSIONS ARE IN MM, UNO.
3. ALL SPLICES SHALL BE CLASS B TENSION SPLICE. PROVIDE TOP REINFORCEMENT SPLICES AT MID SPAN. PROVIDE BOTTOM REINFORCEMENT
SPLICES AT SUPPORTS.
4. PROVIDE 90° STD HOOK AT SLAB ENDS, TYP.
5. CHAMFERS ARE 20MM (MIN), TYP.
"S E
E P
L A
N
"S L A
B T
H
IC
K N
E S
S
GL
TYP
"CLR"
T Y
P "C
L R
"TYP"
CLASS B TENSION SPLICE
GL
D13 AT 250 O/C BEAM REINFORCEMENT, SEE
PLANS AND SCHEDULES, TYP.
TYP
"CLASS B TENSION SPLICE"
1 : 252
TYPICAL GRAVITY CONCRETE BEAM DETAILS
1 : 201
TYPICAL CONCRETE SLAB DETAILS
0 0.2 10.4 0.6 0.8 2
1:20
0 2.51.00.5 1.5
1:25
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
GRAPHIC SCALE
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
/8
/2
:3 :4
P
M
SF505
G R
A V
IT
Y
B E
A M
S A
N D
S L
A B
D E
T A
IL
S
A L I A
L S
A L E
M A
B K
U W
A
IT
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
P H
IL
A
D E
L P
H
IA
D
IS
T R
IC
T
A
R C
H S
T R
E E
T
P H
IL
A
D E
L P
H
IA
P
A
M A
L J U
B O
O R
I
M A
L J U
B O
O R
I
L R
Y A
N
J U
L Y
W
E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5
C C
H A
S T
E N K
U -5
-S
F
S U
B S
T A
T
IO
N
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
E
S
K
C
AT 2H
"K"
AT 2H
"K"
TYP
"SS"
BEAM DETAIL NOTES:
1. THIS DETAIL IS APPLICABLE CONCRETE GRADE BEAMS.
2. ALL DIMENSIONS ARE IN MM, UNO.
3. ALL STIRRUPS START 50MM FROM FACE OF SUPPORTS (SS = 50MM), UNO.
4. ALL SPLICES SHALL BE CLASS B…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .