VOL 14 OF 14_FACILITY STD_DRAWINGS_CDC_JUL 2026.pdf
PDF 7 MB Posted
- Attached to
- Apache Alert Mission Complex
- Solicitation number
- W912ER26RA016
About this file
This file is a set of facility standard drawings for the Apache Alert Mission Complex project. The document represents Volume 14 of 14 in a comprehensive drawing package and contains CDC (Construction Documents) standard facility drawings dated July 2026. These drawings serve as the technical reference documentation for the design-bid-build construction contract supporting the U.S. Army Corps of Engineers' Apache Alert Mission Complex facility at Ali Al Salem Airbase in Kuwait for the Kuwait Air Force.
The standard drawings included in this volume establish the baseline architectural and engineering specifications, details, and requirements that contractors must follow during construction. As part of a multi-volume drawing set, these documents provide detailed guidance on facility construction standards, building systems, materials, and construction methodologies applicable to the project. Contractors responding to solicitation W912ER26RA016 must review and comply with all specifications outlined in these facility standard drawings as part of their firm fixed-price bid for the complete design-bid-build construction services.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US Army Corps of Engineers ®
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
VOLUME - FACILITY
VOLUME OF 14
FACILITY A - ALERT SHELTER
FACILITY C - LOGISTICS READINESS CENTER
FACILITY D - MAINTENANCE SUPPLY WAREHOUSE
FACILITY F - GUARD HOUSE
FACILITY H - PILOT READINESS FACILITY
FACILITY J - POL SHED
FACILITY K - SUBSTATION
FACILITY M - STORAGE SHADE
FACILITY N - WASH RACK SUNSHADE
FACILITY O - FIRE WATER PUMP HOUSE
GENERAL NOTES AND SITE DESIGN
INDEX OF VOLUMES
VOLUME
NUMBER
VOLUME TITLE
FACILITY G1 - SUNSHADES - SINGLE
FACILITY E - ALERT MAGAZINE
FACILITY STD - STANDARD DETAILS14
MIDDLE EAST DISTRICT
X:\REVIT PROJECTS\KUWAIT\2023\KU-509974-2 - APACHE ALERT MISSION FACILITIES\STD - STANDARD DETAILS\KU-509974-2STD-DM-G_RVT25.rvt
7/15/2026 3:28:09 PM
/1
/2
:2 :0
P
M
ALI AL SALEM AB, KUWAIT
KMOD – KUWAIT AIR FORCE
W912ER26RA016
JULY 2026
KU-509974-2
KUWAIT APACHE ALERT FACILITES
GI001
F A
C
IL
IT
Y
C O
V E
R S
H E
E T
A L I A
L S
A L E
M A
B K
U W
A
IT
C O
'B A
N N
O N
C O
'B A
N N
O N
E S
T
IL
L M
A N
J U
L Y
W E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
D R
A C
K M
A L E
S
K U
-5 -2
S T
D -G
I0
S T
A N
D A
R D
D E
T A
IL
S
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
E
S
STD
C D
C
STD - STANDARD DETAILS14
of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
File Path:
Plot Date:
M A
R K
D E
S C
R
IP
T
IO
N
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
X:\REVIT PROJECTS\KUWAIT\2023\KU-509974-2 - APACHE ALERT MISSION FACILITIES\STD - STANDARD DETAILS\KU-509974-2STD-DM-G_RVT25.rvt
7/15/2026 3:28:09 PM
/1
/2
:2 :0
P
M
GI011
IN
D
E X
O F
D R
A W
IN
G
S
A L I A
L S
A L E
M A
B K
U W
A
IT
C O
'B A
N N
O N
C O
'B A
N N
O N
E S
T
IL
L M
A N
J U
L Y
W E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
D R
A C
K M
A L E
S
K U
-5 -2
S T
D -G
I0
S T
A N
D A
R D
D E
T A
IL
S
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
E
S
STD
C D
C
INDEX OF DRAWINGS
KU-509974-2 - STANDARD DETAILS
SHEET
ID
FILE NAME REV. NO.
AM/COP
NO.
SHEET TITLE
GENERAL
GI001 KU-509974-2STD-GI001 FACILITY COVER SHEET
GI011 KU-509974-2STD-GI011 INDEX OF DRAWINGS
STRUCTURAL
SS001 KU-509974-2STD-SS001 GENERAL NOTES
SS002 KU-509974-2STD-SS002 GENERAL NOTES
SS003 KU-509974-2STD-SS003 GENERAL NOTES
SS004 KU-509974-2STD-SS004 STRUCTURAL ABBREVATIONS AND SYMBOLS
SS501 KU-509974-2STD-SS501 TYPICAL STRUCTURAL DETAILS - SHEET 1
SS502 KU-509974-2STD-SS502 TYPICAL STRUCTURAL DETAILS - SHEET 2
SS503 KU-509974-2STD-SS503 TYPICAL STRUCTURAL DETAILS - SHEET 3
SS504 KU-509974-2STD-SS504 TYPICAL STRUCTURAL DETAILS - SHEET 4
SS505 KU-509974-2STD-SS505 TYPICAL CMU WALL DETAILS - SHEET 1
SS506 KU-509974-2STD-SS506 TYPICAL CMU WALL DETAILS (ELEVATION) - SHEET 2
SS507 KU-509974-2STD-SS507 TYPICAL CMU WALL DETAILS - SHEET 3
SS508 KU-509974-2STD-SS508 CONCRETE FOUNDATION DETAILS
SS509 KU-509974-2STD-SS509 CONCRETE WALL AND ELEVATED SLAB DETAILS
SS510 KU-509974-2STD-SS510 MISCELLANEOUS CONCRETE DETAILS
SS511 KU-509974-2STD-SS511 MBS FOUNDATION DETAILS - SHEET 1
SS512 KU-509974-2STD-SS512 TYPICAL STRUCTURAL DETAILS (MISCELLANEOUS)
SS513 KU-509974-2STD-SS513 COLD-FORMED METAL FRAMING TYPICAL DETAILS
SS601 KU-509974-2STD-SS601 MATERIAL SCHEDULES
ARCHITECTURAL
SA001 KU-509974-2STD-SA001 GENERAL ARCHITECTURAL NOTES
SA501 KU-509974-2STD-SA501 INTERIOR WALL TYPES
SA502 KU-509974-2STD-SA502 WALL DETAILS
SA503 KU-509974-2STD-SA503 COLUMN DETAILS
SA504 KU-509974-2STD-SA504 INSULATED METAL PANEL DETAILS
SA505 KU-509974-2STD-SA505 FLOOR FINISHES AND DETAILS
SA506 KU-509974-2STD-SA506 MISC. EXTERIOR DETAILS
SA507 KU-509974-2STD-SA507 CEILING DETAILS
SA508 KU-509974-2STD-SA508 WINDOW AND DOOR TYPES
SA509 KU-509974-2STD-SA509 DOOR OPENING DETAILS
SA510 KU-509974-2STD-SA510 WINDOW DETAILS
SA511 KU-509974-2STD-SA511 TRANSLUCENT PANEL DETAILS
SA512 KU-509974-2STD-SA512 OVERHEAD DOOR DETAILS
SA513 KU-509974-2STD-SA513 PARAPET DETAILS
SA514 KU-509974-2STD-SA514 ROOF DETAILS
SA515 KU-509974-2STD-SA515 ROOF ACCESS LADDER DETAILS
SA516 KU-509974-2STD-SA516 ROOF SCREEN DETAILS
SA517 KU-509974-2STD-SA517 ROOF SCREEN DETAILS
SA518 KU-509974-2STD-SA518 STAIR DETAILS
SA519 KU-509974-2STD-SA519 STAIR DETAILS
SA520 KU-509974-2STD-SA520 FIXTURE HEIGHTS
SA521 KU-509974-2STD-SA521 SIGNAGE DETAILS
SA522 KU-509974-2STD-SA522 SIGNAGE DETAILS
SA523 KU-509974-2STD-SA523 FINISHES
SA524 KU-509974-2STD-SA524 HANGAR DOOR
SA525 KU-509974-2STD-SA525 CASEWORK DETAILS
INDEX OF DRAWINGS
KU-509974-2 - STANDARD DETAILS
SHEET
ID
FILE NAME REV. NO.
AM/COP
NO.
SHEET TITLE
FIRE PROTECTION
SF001 KU-509974-2STD-SF001
FIRE ALARM AND LIFE SAFETY STANDARD DETAILS AND
SYMBOLS
SF002 KU-509974-2STD-SF002 FIRE ALARM AND DETECTION SYSTEM - STANDARD DETAILS
SF003 KU-509974-2STD-SF003
FIRE SUPPRESSION AND EXTINGUISHING SYSTEMS
STANDARD DETAILS
SF501 KU-509974-2STD-SF501 FIRE ALARM GENERAL INSTALLATION DETAILS
SF502 KU-509974-2STD-SF502
FIRE PUMPS, WATER STORAGE, SUPPRESSION CONCEPT
PLAN
PLUMBING
SP001 KU-509974-2STD-SP001 GENERAL NOTES, ABBREVIATIONS AND SYMBOLS
SP500 KU-509974-2STD-SP500 PLUMBING DETAILS - SHEET 1
SP501 KU-509974-2STD-SP501 PLUMBING DETAILS - SHEET 2
SP502 KU-509974-2STD-SP502 PLUMBING DETAILS - SHEET 3
SP503 KU-509974-2STD-SP503 PLUMBING DETAILS - SHEET 4
MECHANICAL
SM001 KU-509974-2STD-SM001 GENERAL NOTES, ABBREVIATIONS AND SYMBOLS
SM002 KU-509974-2STD-SM002 SEQUENCE OF OPERATIONS
SM003 KU-509974-2STD-SM003 SEQUENCE OF OPERATIONS
SM004 KU-509974-2STD-SM004 SEQUENCE OF OPERATIONS
SM500 KU-509974-2STD-SM500 MECHANICAL DETAILS - SHEET 1
SM501 KU-509974-2STD-SM501 MECHANICAL DETAILS - SHEET 2
SM502 KU-509974-2STD-SM502 MECHANICAL DETAILS - SHEET 3
SM503 KU-509974-2STD-SM503 MECHANICAL DETAILS - SHEET 4
SM504 KU-509974-2STD-SM504 MECHANICAL DETAILS - SHEET 5
SM505 KU-509974-2STD-SM505 MECHANICAL DETAILS - SHEET 6
SM506 KU-509974-2STD-SM506 MECHANICAL DETAILS - SHEET 7
SM601 KU-509974-2STD-SM601 HVAC REGISTER SCHEDULES
ELECTRICAL
SE001 KU-509974-2STD-SE001 ELECTRICAL GENERAL & NOTES
SE002 KU-509974-2STD-SE002 ELECTRICAL GENERAL & NOTES
SE003 KU-509974-2STD-SE003 ELECTRICAL GENERAL & NOTES
SE501 KU-509974-2STD-SE501 LIGHTING DETAILS
SE502 KU-509974-2STD-SE502 LIGHTING DETAILS
SE503 KU-509974-2STD-SE503 LIGHTING DETAILS AND SCHEDULE
SE504 KU-509974-2STD-SE504 LIGHTING DETAILS OTHER
SE505 KU-509974-2STD-SE505 LIGHTING CONTROL WIRING SCHEMATICS
SE506 KU-509974-2STD-SE506 LIGHTING CONTROL WIRING SCHEMATICS
SE507 KU-509974-2STD-SE507 LIGHTING CONTROL NETWORK DIAGRAM
SE508 KU-509974-2STD-SE508 LIGHTING CONTROL NETWORK DIAGRAM
SE509 KU-509974-2STD-SE509 POWER DETAILS
SE510 KU-509974-2STD-SE510 POWER DETAILS
SE511 KU-509974-2STD-SE511 POWER DETAILS
SE512 KU-509974-2STD-SE512 POWER DETAILS
SE513 KU-509974-2STD-SE513 POWER DETAILS
SE514 KU-509974-2STD-SE514 LIGHTNING PROTECTION & GROUNDING DETAILS
SE515 KU-509974-2STD-SE515 LIGHTNING PROTECTION & GROUNDING DETAILS
SE516 KU-509974-2STD-SE516 LIGHTNING PROTECTION & GROUNDING DETAILS
SE517 KU-509974-2STD-SE517 LIGHTNING PROTECTION & GROUNDING DETAILS
SE518 KU-509974-2STD-SE518 LIGHTNING PROTECTION & GROUNDING DETAILS
INDEX OF DRAWINGS
KU-509974-2 - STANDARD DETAILS
SHEET
ID
FILE NAME REV. NO.
AM/COP
NO.
SHEET TITLE
TELECOMMUNICATIONS
TN500 KU-509974-2STD-TN500 TELECOMMUNICATIONS LEGEND
TN501 KU-509974-2STD-TN501 TELECOMMUNICATIONS DETAILS
TN502 KU-509974-2STD-TN502 TELECOMMUNICATIONS DETAILS
TN503 KU-509974-2STD-TN503 TELECOMMUNICATIONS DETAILS
TN504 KU-509974-2STD-TN504 TELECOMMUNICATIONS DETALS
TN505 KU-509974-2STD-TN505 TELECOMMUNICATIONS DETAILS
TN506 KU-509974-2STD-TN506 TELECOMMUNICATIONS DETAILS
TN507 KU-509974-2STD-TN507 TELECOMMUNICATIONS DETAILS
TN508 KU-509974-2STD-TN508 TELECOMMUNICATIONS DETAILS
TN509 KU-509974-2STD-TN509 TELECOMMUNICATIONS DETAILS
TN510 KU-509974-2STD-TN510 TELECOMMUNICATIONS DETAILS
TN511 KU-509974-2STD-TN511 TELECOMMUNICATIONS DETAILS
TN512 KU-509974-2STD-TN512 TELECOMMUNICATIONS DETAILS
TN513 KU-509974-2STD-TN513 TELECOMMUNICATIONS DETAILS
TN514 KU-509974-2STD-TN514 TELECOMMUNICATIONS DETAILS
TN515 KU-509974-2STD-TN515 TELECOMMUNICATIONS DETAILS
TN516 KU-509974-2STD-TN516 TELECOMMUNICATIONS DETAILS
TN517 KU-509974-2STD-TN517 TELECOMMUNICATIONS DETAILS
TN518 KU-509974-2STD-TN518 TELECOMMUNICATIONS DETAILS
TS501 KU-509974-2STD-TS501 STANDARD TELECOM DETAILS
TS502 KU-509974-2STD-TS502 STANDARD TELECOM DETAILS
TS503 KU-509974-2STD-TS503 STANDARD TELECOM DETAILS
TS504 KU-509974-2STD-TS504 STANDARD TELECOM DETAILS
TS505 KU-509974-2STD-TS505 STANDARD TELECOM DETAILS
G-1 METHODS, PROCEDURES AND SEQUENCES OF CONSTRUCTION ARE THE
RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR IS
RESPONSIBLE FOR IDENTIFYING AND IMPLEMENTING THE NECESSARY
PRECAUTIONS TO MAINTAIN AND ENSURE THE INTEGRITY OF THE
STRUCTURE AT ALL STAGES OF CONSTRUCTION.
G-2 ALL DIMENSIONS ARE IN MILLIMETERS (mm) UNLESS NOTED OTHERWISE.
G-3 TEMPORARY BRACING, SHEETING, SHORING, ETC, REQUIRED TO ENSURE
THE STRUCTURAL INTEGRITY/STABILITY OF THE EXISTING BUILDINGS,
SIDEWALKS, UTILITIES, ETC, DURING CONSTRUCTION IS THE
RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE DESIGNED BY A
REGISTERED PROFESSIONAL ENGINEER EMPLOYED BY THE
CONTRACTOR.
G-4 IMPLEMENTATION OF JOB SITE SAFETY IS THE SOLE RESPONSIBILITY OF
THE CONTRACTOR.
G-5 WHEN NOT SPECIFICALLY INDICATED ON THE STRUCTURAL DRAWINGS,
THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING SLEEVE AND
BLOCK-OUT REQUIREMENTS FOR PENETRATIONS PRIOR TO FABRICATION
OR ERECTION OF THE STRUCTURE. PENETRATIONS OF STRUCTURAL
MEMBERS ARE SUBJECT TO APPROVAL BY THE CONTRACTING
OFFICER. THE CONTRACTOR IS ALSO RESPONSIBLE FOR DETERMINING
ANCHORAGE AND HANGER REQUIREMENTS REQUIRED FOR SUPPORTING
EQUIPMENT, FINISHES, UTILITIES ETCETERA NOT INDICATED ON THE
STRUCTURAL DRAWINGS.
G-6 THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING AND
COORDINATING DIMENSIONS AND INSTALLATION DETAILS OF
PURCHASED EQUIPMENT WITH THE SUPPORTING STRUCTURE. ANY
CONFLICTS BETWEEN THESE ITEMS AND THE BUILDING STRUCTURE ARE
TO BE BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER
FOR RESOLUTION.
G-7 THE STRUCTURAL DRAWINGS GOVERN THE WORK FOR STRUCTURAL
FEATURES, UNLESS OTHERWISE NOTED. DIMENSIONS SHOWN ON PLANS
AND DETAILS ARE TO GOVERN THE STRUCTURAL WORK. THE
CONTRACTOR IS TO REFER TO THE ARCHITECTURAL DRAWINGS FOR
DIMENSIONS AND DETAILS NOT PROVIDED. DIMENSIONAL CONFLICTS IN
THE DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE
CONTRACTING OFFICER.
G-8 FOR ADDITIONAL INFORMATION NOT COVERED IN THESE GENERAL
NOTES, REFER TO THE PROJECT SPECIFICATIONS. IN CASE OF CONFLICT
BETWEEN THE GENERAL NOTES, SPECIFICATIONS, AND DRAWINGS, THE
MOST STRINGENT REQUIREMENTS AS DETERMINED BY THE
CONTRACTING OFFICER WILL GOVERN.
G-9 WHERE CERTAIN FEATURES ARE NOT FULLY SHOWN OR DETAILED ON
THE CONTRACT DOCUMENTS, THEIR CONSTRUCTION MUST BE OF THE
SAME CHARACTER AS FOR SIMILAR CONDITIONS THAT ARE FULLY
SHOWN OR DETAILED.
G-10 DETAILS DESIGNATED AS “TYPICAL DETAILS,” APPLY GENERALLY TO THE
DRAWINGS IN AREAS WHERE CONDITIONS ARE SIMILAR TO THOSE
DESCRIBED IN THE DETAILS.
G-11 SHOP DRAWINGS:
A. SHOP DRAWINGS FOR ALL MATERIALS ARE TO BE SUBMITTED TO THE
CONTRACTING OFFICER FOR REVIEW PRIOR TO THE START OF
FABRICATION OR COMMENCEMENT OF WORK PER THE PROJECT
SPECIFICATIONS.
B. SHOP DRAWINGS MUST BE CHECKED AND STAMPED BY THE
CONTRACTOR PRIOR TO SUBMISSION. THE CONTRACTOR’S STAMP
OF APPROVAL WILL CONSTITUTE CERTIFICATION THAT HE HAS
VERIFIED ALL FIELD MEASUREMENTS, CONSTRUCTION CRITERIA,
MATERIALS AND SIMILAR DATA AND HAS CHECKED EACH DRAWING
FOR COMPLETENESS, COORDINATION, AND COMPLIANCE WITH THE
CONTRACT DOCUMENTS.
C. REPRODUCTION OF ANY PORTION OF THE STRUCTURAL CONTRACT
DRAWINGS FOR SUBMITTAL AS SHOP DRAWINGS IS PROHIBITED.
D. CHANGES TO SHOP DRAWINGS THAT ARE RE-SUBMITTED MUST BE
CLOUDED OR SOMEHOW INDICATE THAT A CHANGE HAS BEEN MADE
TO PREVIOUSLY ISSUED AND REVIEWED DRAWING.
E. THE CONTRACTOR IS TO PROVIDE THE CONTRACTING OFFICER WITH
WRITTEN NOTICE OF DEVIATIONS OF ANY TYPE FROM THE
REQUIREMENTS OF THE CONSTRUCTION DOCUMENTS. THE NOTICE
MUST BE RECEIVED PRIOR TO SHOP DRAWING SUBMITTAL. THE
CONTRACTOR REMAINS LIABLE FOR ANY DEVIATION UNLESS
REVIEWED BY THE CONTRACTING OFFICER AND ACKNOWLEDGED IN
WRITING, PRIOR TO THE RECEIPT OF THE SHOP DRAWINGS.
GENERAL F-4 ALL FOOTINGS ARE TO BEAR A MINIMUM OF 1500mm BELOW
FINISHED GRADE, UNLESS NOTED OTHERWISE. ELEVATIONS SHOWN ON
THE DRAWINGS AT WHICH FOUNDATIONS BEAR ARE APPROXIMATE AND
MAY VARY TO SUIT SUBSURFACE SOIL CONDITIONS. ANY STEP-IN
FOOTING LOCATIONS SHOWN ON THE DRAWINGS ARE TO BE FIELD
VERIFIED AND ADJUSTED AS REQUIRED SO THAT FOUNDATIONS BEAR ON
MATERIAL OF AT LEAST THE CAPACITY NOTED AND ON SUITABLE IN-SITU
SOIL OR COMPACTED STRUCTURAL FILL PER THE GEOTECHNICAL
RECOMMENDATIONS AND SPECIFICATIONS. AT LOCATIONS WHERE
FOUNDATIONS WILL NOT BEAR DIRECTLY ON BEDROCK, A PLATE LOAD
TEST IS REQUIRED TO CONFIRM BEARING CAPACITY MEETS MINIMUM
BEARING CAPACITY PER THE GENERAL NOTES SPECIFIC TO EACH
BUILDING.PLATE LOAD TEST IS NOT REQUIRED WHERE THE DESIGN
CRITERIA FOR EACH BUILDING INDICATES THAT FOUNDATIONS WERE
DESIGNED TO BEAR ON ENGINEERED FILL.
F-5 PRIOR TO PLACING CONCRETE, ANY WATER PRESENT IS TO BE PUMPED
OUT FROM THE BOTTOM OF EXCAVATIONS.
F-6 CONCRETE SLABS-ON-GRADE HAVE BEEN DESIGNED TO BEAR ON
PROPERLY COMPACTED SUB-GRADE SOILS AS PER THE DESIGN
CRITERIA FOR EACH BUILDING. THE DRAINAGE BASE COURSE MATERIAL
BENEATH THE SLAB- ON-GRADE IS TO CONFORM TO ASTM D 1241, TYPE 1,
GRADATION B AND BE COMPACTED IN ACCORDANCE WITH 95%
STANDARD DENSITY PER ASTM D 698 (MAXIMUM FILL LIFT = 200mm).
F-7 NO BACKFILLING AGAINST WALLS IS TO BE DONE UNTIL THE SLABS AT
THE TOP AND BOTTOM HAVE BEEN PLACED OR ADEQUATE SHORING HAS
BEEN PROVIDED. WALLS AND GRADE BEAMS HAVING BACKFILL AGAINST
BOTH SIDES ARE TO HAVE BACKFILL PLACED ON BOTH SIDES UNIFORMLY
SO AS NOT TO EXCEED A 200mm DIFFERENTIAL.
F-8 EQUIPMENT AND/OR MATERIALS WITH WEIGHT GREATER THAN THE
DESIGN SURCHARGE MUST MAINTAIN A SAFE HORIZONTAL CLEAR
DISTANCE FROM BASEMENT AND RETAINING WALLS. A SAFE
HORIZONTAL CLEAR DISTANCE IS DEFINED AS THE DISTANCE FROM THE
BASE OF THE RETAINING WALL TO THE TOP OF FINISHED GRADE.
F-9 FOR METAL BUILDING SYSTEMS, THE FOUNDATION SYSTEM HAS BEEN
DESIGNED TO SUPPORT METAL BUILDING SYSTEMS BASED
UPON A DESIGN ANALYSIS PERFORMED BY THE STRUCTURAL ENGINEER.
THE FOLLOWING CONCRETE REQUIREMENTS FOR METAL BUILDING
SYSTEMS APPLY:
A. THE FOUNDATION MUST BE SQUARE AND LEVEL. OUT OF LEVEL
TOLERANCE FOR TOP OF CONCRETE PIERS AND WALLS IS ± 3mm IN 6000mm AND ± 6mm IN OVERALL LENGTH. TOLERANCE BETWEEN CENTERLINES OF COLUMN ANCHOR BOLT CLUSTERS IS ± 3mm IN 6000mm AND ± 6mm OVERALL.
B. ADJUST THE ELEVATION OF THE TOP OF PIERS IN ACCORDANCE WITH
BUILDING MANUFACTURER'S STANDARD. TROWEL FINISH TOP OF
CONCRETE AT COLUMN BASES.
C. ADJUST DIMENSIONS OF CONCRETE PIERS GIVEN TO PROVIDE A
MINIMUM 50mm BEYOND ALL SIDES OF COLUMN BASE PLATE. NOTE:
PIER SIZE GIVEN IS MINIMUM, ANY REVISIONS TO PIER SIZES SHOWN
ON THE DRAWINGS SHALL BE PROVIDED TO THE ENGINEER FOR
REVIEW.
D. ANCHOR RODS MUST BE SET BY MEANS OF A TEMPLATE. (DO NOT
HAND SET)
E. MISCELLANEOUS JAMB POSTS ARE TO BE ANCHORED TO
FOUNDATION BY MEANS OF POST-INSTALLED ANCHORS AS PER
BUILDING MANUFACTURER'S DRAWINGS.
C-11 REINFORCEMENT IS TO BE SECURELY HELD IN PLACE WHILE PLACING
CONCRETE. IF REQUIRED, ADDITIONAL BARS, STIRRUPS, OR CHAIRS
WILL BE PROVIDED BY THE CONTRACTOR TO FURNISH SUPPORT FOR
ALL BARS WHERE NECESSARY DURING CONSTRUCTION.
C-12 CONTINUOUS REINFORCING BARS TO BE TURNED AND LAPPED AT
CORNERS AND INTERSECTIONS OF WALLS AND FOOTINGS. HOOKED
BARS TO HAVE STANDARD ACI HOOKS AS NOTED ON SS601.
C-13 CONTINUOUS TOP BARS TO BE SPLICED AT MID-SPAN. CONTINUOUS
BOTTOM BARS TO BE SPLICED AT CENTERLINE OF SUPPORTS (OR AS
SHOWN ON DETAILS).
C-14 WELDED WIRE REINFORCEMENT IS TO BE SUPPLIED IN FLAT SHEETS
ONLY. LAP WELDED WIRE REINFORCEMENT TWO FULL MESH LENGTHS
AT SPLICES AND WIRE TOGETHER. PLACE WELDED WIRE
REINFORCEMENT WITHIN THE SLAB THICKNESS PER THE TYPICAL
DETAILS.
C-15 CONCRETE SLABS TO BE CURED BY METHOD COMPATIBLE WITH
SPECIFIED FLOOR FINISH. WHERE ACCEPTABLE USE A LIQUID
MEMBRANE-CURING COMPOUND AT THE MANUFACTURERS
RECOMMENDED COVERAGE.
C-16 SLOPE SLABS-ON-GRADE TO DRAIN AS REQUIRED. MAINTAIN MINIMUM
DESIGN THICKNESS INDICATED.
C-17 DIVIDE FLOOR SLABS-ON-GRADE INTO SEGMENTS BY MEANS OF
ISOLATION, CONTROL AND CONSTRUCTION JOINTS AS INDICATED ON THE
DRAWINGS. SAW JOINTS TO BE CUT AS SOON AS POSSIBLE WITHOUT
RAVELING THE SURFACE. POSITION OF CONSTRUCTION JOINTS OTHER
THAN THOSE SHOWN ON THE DRAWINGS ARE TO BE SUBMITTED TO THE
CONTRACTING OFFICER FOR APPROVAL.
C-18 SLAB-ON-GRADE CONTROL JOINTS TO BE PLACED AT COLUMNS
PER DETAIL 1/SS502 UNO. CONTROL JOINTS TO BE PLACED AT EQUAL
INTERVALS IN EACH DIRECTION AS INDICATED ON THE PLANS. ADAPT
CONTROL JOINT LOCATION AT ODD BAYS. CONSTRUCTION JOINTS TO BE
PLACED AT CONTROL JOINT LOCATIONS AT CONTRACTOR’S DISCRETION
UNO ON PLAN.
C-19 LEVELING GROUT TO BE NON-SHRINK, NON-METALLIC TYPE, FACTORY
PREMIXED GROUT IN ACCORDANCE WITH ASTM C 1107, HAVING A
MINIMUM COMPRESSIVE STRENGTH OF NOT LESS THAN 25 MPa, AT 24 HOURS, 40 MPa AT 7 DAY, AND 50 MPa, AT 28 DAYS.
C-20 PROVIDE FINISHED SLAB-ON-GRADE WITH SPECIFIED OVERALL VALUES
OF FLATNESS (Ff) AND LEVELNESS (FI) ALONG WITH MINUMUM LOCAL VALUES OF FLATNESS (Ff) AND LEVELNESS (FI), AS LISTED IN THE
SPECIFICATIONS.
C-21 SLEEVES, INSERTS, MECHANICAL OPENINGS, CONDUITS, PIPES,
RECESSES, DEPRESSIONS, CURBS AND OTHER EMBEDDED ITEMS TO BE
PROVIDED FOR AS SHOWN ON THE ARCHITECTURAL, MECHANICAL AND
ELECTRICAL DRAWINGS AND AS REQUIRED BY EQUIPMENT
MANUFACTURERS. INSTALLATION OF THESE ITEMS TO BE COORDINATED
AND PROVIDED FOR PRIOR TO PLACING CONCRETE.
C-22 ANCHOR RODS FOR METAL BUILDING SYSTEMS TO BE
ASTM F 1554 Fy=275 MPa MINIMUM, UNLESS NOTED OTHERWISE.
DIAMETER AND LOCATIONS SHALL BE AS INDICATED ON THE METAL
BUILDING SYSTEMS DRAWINGS (BY OTHERS).
C-23 PROVIDE 20MM X 20MM CHAMFER UNO TO ABOVE GRADE EXPOSED TO
VIEW JOINTS, EDGES, AND EXTERNAL CORNERS OF CONCRETE.
C-24 NO REINFORCING SPLICING ALLOWED WITHIN THE SHEAR WALL
BOUNDARY REGION.
C-25 ROUGHEN CONCRETE SURFACE TO 6MM AMPLITUDE AT ALL JOINTS.
F-1 FOUNDATIONS HAVE BEEN DESIGNED AND ARE TO BE CONSTRUCTED IN
ACCORDANCE WITH CRITERIA USED FOR DESIGN. THE CONTRACTOR
SHALL VERIFY THESE PRIOR TO CONSTRUCTION.
F-2 FOUNDATIONS ARE TO BE PLACED ON UNDISTURBED SOIL OR
COMPACTED FILL CONFORMING TO 95% STANDARD DENSITY PER
ASTM D 698 (MAXIMUM FILL LIFT = 200mm).
F-3 THE CONTRACTOR IS TO RETAIN THE SERVICES OF A PROFESSIONAL
GEOTECHNICAL ENGINEER, SUBJECT TO THE APPROVAL OF THE
CONTRACTING OFFICER, TO VERIFY THAT THE MATERIAL ON WHICH
FOUNDATIONS BEAR HAS AT LEAST THE CAPACITY AS NOTED IN THE
DESIGN CRITERIA FOR EACH BUILDING. THE GEOTECHNICAL ENGINEER
IS TO MAKE RECOMMENDATIONS FOR IMPROVING AREAS THAT DO NOT
MEET THE DESIGN CRITERIA.
FOUNDATIONS
C-1 REINFORCED CONCRETE WORK IS TO BE IN ACCORDANCE WITH THE ACI
BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI
318-19) AND THE “SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR
BUILDINGS- ACI 301”(LATEST EDITION).
C-2 MIXING, TRANSPORTATION, PLACING AND TESTING OF CONCRETE ARE TO
BE DONE IN ACCORDANCE WITH ACI 301M OR EQUIVALENT BRITISH
STANDARD.
C-3 PRIOR TO CONCRETE PLACEMENT, THE CONTRACTOR MUST SUBMIT
CONCRETE MIX DESIGNS FOR EACH TYPE OF CONCRETE TO BE USED,
PREPARED IN ACCORDANCE WITH THE SPECIFICATIONS TO THE
CONTRACTING OFFICER FOR REVIEW.
C-4 CAST-IN-PLACE CONCRETE SHALL HAVE A MINIMUM 28 DAY CYLINDER
COMPRESSIVE STRENGTH (f'c) AS INDICATED ON THE CONCRETE
MATERIALS SCHEDULE ON DRAWING SS601.
C-5 THE SLUMP AT POINT OF PLACEMENT IS NOT TO EXCEED 100mm ± 25mm
AND THE WATER/CEMENT RATIO IS NOT TO EXCEED VALUES AS NOTED
ON SS004. IF ADDITIONAL SLUMP (UP TO 200mm) IS DESIRED FOR
PUMPING, A SUPER-PLASTICIZER ADMIXTURE MAY BE ADDED.
C-6 AIR ENTRAINMENT ADMIXTURE SHALL CONFORM TO ASTM C260.
C-7 REINFORCEMENT:
A. DEFORMED BARS: ASTM A 615 OR EQUIVALENT
B. WELDED WIRE REINFORCEMENT: ASTM A 1064 OR EQUIVALENT
C-8 REINFORCEMENT IS TO BE DETAILED, FABRICATED, AND PLACED IN
ACCORDANCE WITH THE ACI "DETAILING MANUAL NO. SP-66” (LATEST
EDITION).
C-9 SPLICES (LAPS) OF REINFORCING BARS SHALL BE CLASS ‘B’ TENSION
LAPS PER ACI STANDARDS UNLESS NOTED OTHERWISE. REFER TO THE
MINIMUM LAP SPLICES OF REINFORCING BARS IN TENSION SCHEDULE ON
DRAWING SS601.
C-10 PROVIDE ADEQUATE CONCRETE COVER IN ACCORDANCE WITH THE
REQUIREMENTS AS SET FORTH BY ACI 318. REFER TO THE CONCRETE
COVER SCHEDULE ON DRAWING SS601.
REINFORCED CONCRETE
M-1 MASONRY WORK MUST BE IN CONFORMANCE WITH THE BUILDING CODE
REQUIREMENTS AND SPECIFICATION FOR MASONRY STRUCTURES (TMS
402/602).
M-2 ALL MORTAR TO CONFORM TO ASTM C 270, TYPE S OR BS EN 998 PART 2.
A. PORTLAND CEMENT: ASTM C 150, TYPE I.
B. LIME: ASTM C 207 OR BS EN 459 PART 1.
M-3 GROUT IS TO CONFORM TO ASTM C 476 OR BS EN 206 AND HAVE A
MINIMUM COMPRESSIVE STRENGTH OF 14 MPa A. SLUMP: 200mm TO 250mm.
B. MAXIMUM AGGREGATE SIZE: 9.5mm.
M-4 CONCRETE MASONRY TO HAVE A MINIMUM 28 DAY COMPRESSIVE
STRENGTH OF MASONRY (f'm) EQUAL TO 10.5MPa AND:
A. HOLLOW BLOCK: ASTM C 90 OR BS EN 7714, NORMAL WT.
B. SOLID BLOCKS: ASTM C 90 OR BS EN7714.
M-5 DEFORMED BAR REINFORCEMENT PER ASTM A 615/A 615M GRADE 420 OR
EQUIVALENT.
A. PROVIDE MINIMUM LAP SPLICES OF 48 BAR DIAMETERS.
B. PROVIDE BAR SPACERS AS REQUIRED TO PROPERLY LOCATE
REINFORCING WITHIN CMU CELLS.
MASONRY
M-6 HORIZONTAL JOINT REINFORCING TO BE SPACED AT 400 OC IN ALL WALLS
UNO AND SHALL BE GALVANIZED, STANDARD CLASS, LADDER TYPE,
CONFORMING TO ASTM A951. SIDE RODS TO BE 0.3mm MIN, WEIGHT = 0.87kg/m2 PROVIDE ONE-PIECE PREFABRICATED REINFORCING UNITS AT 200mm OC AT ALL WALL CORNERS AND INTERSECTIONS AND IN THE FIRST
TWO COURSES ABOVE AND BELOW MASONRY OPENINGS. PROVIDE LAP
AS RECOMMENDED BY THE MANUFACTURER WITH A MINIMUM OF 150mm
UNO. DISCONTINUE HORIZONTAL JOINT REINFORCING AT CONTROL
JOINTS.
M-7 ALL MASONRY TO BE CONSTRUCTED USING A RUNNING BOND PATTERN.
FULL BED AND HEAD JOINTS MUST BE USED.
M-8 GROUT CELLS OF CMU SOLID FOR ALL CMU LINTELS, BOND BEAMS, AND
CELLS WITH VERTICAL REINFORCEMENT.
M-9 CONTROL JOINT SPACING IN MASONRY WALLS SHALL BE PROVIDED
WHERE INDICATED ON THE ARCHITECTURAL DRAWINGS, OR A MAXIMUM
OF 7300mm ON CENTER.
M-10 ALL MASONRY WALLS TO BE TEMPORARILY BRACED UNTIL FLOOR OR
ROOF SYSTEM HAS BEEN INSTALLED AND HAS BECOME CAPABLE OF
STABILIZING THE WALLS.
M-11 DOWEL REINFORCED MASONRY WALLS TO FOUNDATION. SIZE DOWELS
TO MATCH WALL REINFORCEMENT. LOCATE DOWELS IN CELLS TO
CONTAIN WALL REINFORCEMENT. LAP DOWELS WITH WALL
REINFORCEMENT A MINIMUM OF 48 BAR DIAMETERS UNO.
M-12 DURING CONSTRUCTION, COVER AND PROTECT THE TOPS OF MASONRY
WALLS AT THE END OF EACH DAY.
M-13 UNLESS NOTED OTHERWISE, PLACE TYPICAL CMU REINFORCMENT IN
CENTER OF FULLY GROUTED CELLS AND SPACE AS FOLLOWS:
A. 150 CMU (INT, NON-BRG): (1) D12 VERTICAL AT 1200mm OC, UNO.
B. 200 CMU (INT, NON-BRG): (1) D12 VERTICAL AT 1200mm OC, UNO.
C. 200 CMU (EXT, NON-BRG): (1) D16 VERTICAL AT 400mm OC, UNO.
a. AT MBS EXTERIOR WALLS, MBS SUPPLIER TO PROVIDE
CONTINUOUS LATERAL BRACING AT TOP OF WALL AND AT
ELEVATIONS NOT MORE THAN 4m ABOVE FFE.
D. PROVIDE ADDITIONAL BARS AT CORNERS AND OPENINGS PER TYPICAL
DETAILS.
M-14 UNLESS NOTED OTHERWISE, BOND BEAMS SHALL HAVE A MAXIMUM
VERTICAL SPACING OF 1200mm.
M-15 ALL CORNERS AND INTERSECTIONS TO BE TIED BY MASONRY BOND.
M-16 PROVIDE VERTICAL VENEER CONTROL JOINTS AS INDICATED ON THE
ARCHITECTURAL DRAWINGS.
M-17 SPACE VENEER ANCHORS PER PROJECT SPECIFICATIONS. PROVIDE
ADDITIONAL ANCHORS AT 200mm OC AROUND OPENINGS.
S-1 STRUCTURAL STEEL WORK IS TO BE DETAILED AND CONSTRUCTED IN
ACCORDANCE WITH THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION
(AISC).
S-2 STRUCTURAL STEEL, UNLESS NOTED OTHERWISE, TO CONFORM TO THE
REQUIREMENTS OF ASTM STANDARDS AS INDICATED ON THE STEEL
MATERIAL SCHEDULE ON DRAWING SS601. STEEL SIZES SHALL BE
UNIVERSAL, UNO. CONTRACTOR’S OPTION TO PROVIDE STEEL
CONFORMING TO EQUIVALENT BRITISH STANDARDS, OR BETTER, IN LIEU
OF ASTM STANDARD, AS LISTED IN THE MATERIAL SCHEDULE ON
DRAWING SS601.
S-3 THE STRUCTURAL STEEL FABRICATOR, AND/OR GENERAL CONTRACTOR,
MUST VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS AT THE SITE.
ALL DISCREPANCIES FOUND ARE TO BE REPORTED TO THE
CONTRACTING OFFICER PRIOR TO PREPARATION OF SHOP DRAWINGS.
SHOP DRAWINGS ARE TO INCLUDE ALL FIELD MEASUREMENTS AND
CONDITIONS.
S-4 STRUCTURAL STEEL FABRICATOR IS TO PROVIDE FOR VERTICAL AND
HORIZONTAL FIELD ADJUSTMENT OF ALL SUPPORT ASSEMBLIES.
S-5 CUTS, HOLES, COPING, ETC REQUIRED FOR OTHER TRADES MUST BE
SHOWN ON THE SHOP DRAWINGS AND MADE IN THE SHOP. CUTS OR
BURNING OF HOLES IN THE FIELD WILL NOT BE PERMITTED.
S-6 STEEL BEAMS ARE TO BE EQUALLY SPACED IN BAYS UNLESS OTHERWISE
NOTED.
S-7 FABRICATE AND INSTALL BEAMS WITH NATURAL CAMBER UP UNLESS
CAMBER IS NOTED ON THE DRAWINGS.
S-8 ALL STRUCTURAL STEEL FRAMES ARE TO BE SECURELY BRACED UNTIL
ALL FLOOR SLABS, ROOF DECKS AND SHEAR WALLS HAVE BEEN
INSTALLED AND BECOME CAPABLE OF STABILIZING THE FRAMES.
S-9 BOLTED CONNECTIONS TO BE DESIGNED AND DETAILED ACCORDING TO
AISC TABLE 10-1 OR 10-2 – DOUBLE ANGLE CONNECTIONS. THE MINIMUM
DEPTH OF THE CONNECTION MUST BE MORE THAN 67% OF THE BEAM
DEPTH EXCEPT THAT BEAMS FRAMING TO COLUMNS TO HAVE FULL
DEPTH CONNECTIONS USING 9.5mm MINIMUM CONNECTION ANGLES OR
PLATES.
A. NON-COMPOSITE BEAM CONNECTIONS TO BE DESIGNED FOR ONE
HALF THE UNIFORM LOAD CAPACITY OF THE BEAM AS TABULATED BY
AISC UNLESS HIGHER LOADS ARE INDICATED ON THE DRAWINGS.
B. COMPOSITE BEAMS (SHEAR STUDS ON TOP FLANGE) REQUIRE
CONNECTION CAPACITIES TO BE INCREASED TO 75% LOAD CAPACITY
OF THE BEAM UNLESS HIGHER LOADS ARE INDICATED ON THE
DRAWINGS.
STRUCTURAL STEEL
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
/1
/2
:4 :2
A
M
SS001
G E
N E
R A
L N
O T
E S
A L I A
L S
A L E
M A
B K
U W
A
IT
D O
L A
O N
IP
E
K U
N
M A
L J U
B O
O R
I
K C
H A
N S
A W
A T
J U
L Y
W
E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
A F
R E
E M
A N K
U -5
-2
S T
D -S
S
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
IE
S
C D
C
S-10 UNLESS OTHERWISE NOTED, STRUCTURAL STEEL CONNECTIONS TO BE
SHOP WELDED AND FIELD BOLTED.
A. BOLTS: 19mm DIAMETER ASTM A 325M UNO WITH MATCHING
WASHERS AND HEAVY HEX NUTS.
B. ALL WELDS SHALL BE 8mm FILLET WELDS UNLESS NOTED
OTHERWISE.
S-11 PROVIDE ANCHOR (EXPANSION, SLEEVE, ADHESIVE, SCREEN TUBE, ETC.)
AND INSTALL PER MANUFACTURER’S
INSTRUCTIONS/RECOMMENDATIONS (SIZE, SPACING, EDGE DISTANCES,
SHEAR AND TENSION CAPACITIES).
ANCHORS ARE NOT TO BE INSTALLED UNTIL CONCRETE OR GROUT HAS
REACHED ITS DESIGN STRENGTH. IN NO CASE SHALL A POST-INSTALLED
ANCHOR BE INSTALLED IN CONCRETE HAVING AN AGE OF LESS THAN 21
DAYS AT TIME OF ANCHOR INSTALLATION.
LOCATE ALL REINFORCEMENT AND CONFIRM FINAL ANCHOR LOCATIONS
PRIOR TO DRILLING. IT IS UNACCEPTABLE TO CUT REBAR FOR POST
INSTALLED ANCHORS WITHOUT PRIOR APPROVAL FROM CONTRACTING
OFFICER. USE A ROTARY IMPACT HAMMER WITH CARBIDE BIT AND AN
AUTOMATIC SHUT-OFF DEVICE DESIGNED TO STOP DRILLING IF THE BIT
COMES INTO CONTACT WITH REINFORCING STEEL
S-12 SUBSTITUTION OF EXPANSION ANCHORS FOR EMBEDDED ANCHORS
SHOWN ON THE DRAWINGS WILL NOT BE PERMITTED.
S-13 WELDING TO BE IN ACCORDANCE WITH THE AMERICAN WELDING
SOCIETY (AWS) "STRUCTURAL WELDING CODE-ANSI/AWS D1.1/D1.1M"
(LATEST EDITION). USE E70XX ELECTRODES UNLESS OTHERWISE
INDICATED ON THE DRAWINGS.
S-14 MANUFACTURE STEEL GRATING IN ACCORDANCE WITH THE “METAL BAR
GRATING MANUAL” AS PUBLISHED BY THE NATIONAL ASSOCIATION OF
ARCHITECTURAL METAL MANUFACTURERS, LATEST EDITION.
A. STEEL FOR GRATING TO CONFORM TO ASTM A 1011/A 1011M.
GRATING TO BE TYPE METRIC OPTION WITH GALVANIZED FINISH.
B. ALUMINUM FOR GRATING TO CONFORM TO ASTM B 221. GRATING TO
BE TYPE AS NOTED WITH MILL FINISH, UNO.
S-15 PAINT AND PROTECTION:
A. STRUCTURAL STEEL, UNLESS INDICATED OTHERWISE, TO BE SHOP
CLEANED AND PAINTED ONE SHOP COAT OF FABRICATOR’S
STANDARD RUST INHIBITING PRIMER. TOUCH UP AFTER ERECTION.
B. DO NOT PAINT STEEL WHERE ENCASED WITH CONCRETE, OR AT
FIELD WELD AREAS.
C. DO NOT PAINT THE TOP FLANGE OF BEAMS TO RECEIVE COMPOSITE
SHEAR CONNECTORS.
D. DO NOT PAINT STRUCTURAL STEEL TO BE FIREPROOFED.
E. EXPOSED STRUCTURAL STEEL TO RECEIVE PAINTED FINISH TO BE
SHOP CLEANED AND PRIME PAINTED PER THE SPECIFICATIONS.
REFERENCE ARCHITECTURE FOR FINISH PAINT SYSTEMS.
F. EXPOSED STRUCTURAL STEEL FOR SCREEN WALLS, EQUIPMENT
PLATFORMS, LOOSE ANGLE LINTELS ETC, TO BE HOT DIPPED
GALVANIZED PER ASTM A-123.
G. GALVANIZED FASTENERS AND ACCESSORIES TO BE HOT DIPPED
GALVANIZED PER ASTM A153/A153M.
H. REPAIR DAMAGE TO GALVANIZED COATINGS USING ASTM A780 ZINC
RICH PAINT.
I. PROVIDE MINIMUM 75mm CONCRETE COVER FOR ALL STEEL BELOW
GRADE.
STRUCTURAL STEEL (CONT'D)
MB-1 DESIGN, FABRICATION AND ERECTION OF THE METAL BUILDING SYSTEMS
MUST BE SUFFICIENT TO WITHSTAND LOADS FROM WIND, SNOW,
GRAVITY, STRUCTURAL MOVEMENT AND SEISMIC ACTION WITHOUT
EXCEEDING ALLOWABLE STRESSES AND SHALL BE IN ACCORDANCE
WITH THE FOLLOWING CODES, THE EDITION OF WHICH ARE LISTED ON
THE DRAWINGS:
A. METAL BUILDING MANUFACTURERS ASSOCIATION (MBMA) “METAL
BUILDING SYSTEMS MANUAL”.
B. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
“SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS” AND STEEL
DESIGN GUIDE SERIES 3: “SERVICEABILITY DESIGN CONSIDERATIONS
FOR LOW-RISE BUILDINGS”.
C. IRON AND STEEL INSTITUTE (AISI) “NORTH AMERICAN SPECIFICATION
FOR THE DESIGN OF COLD FORMED STEEL STRUCTURAL MEMBERS”.
D. AMERICAN WELDING SOCIETY (AWS) “STRUCTURAL WELDING CODE
STEEL AWS D1.1/D1.1M”.
E. SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUIDLINGS "AISC
341-16"
F. AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE) "MINIMUM DESIGN
LOADS FOR BUILDINGS AND OTHER STRUCTURES ASCE 7"
MB-2 DEFORMATIONS OF THE METAL BUILDING SYSTEMS (INCLUDING BUT
NOT LIMITED TO LATERAL DRIFT, RACKING OF FRAMES, AND HORIZONTAL
AND OR VERTICAL DEFLECTION OF STRUCTURAL ELEMENTS, CLADDING
OR OTHER SUPPORTED ELEMENTS), IS TO BE LIMITED BY THE
RECOMMENDATIONS SET FORTH IN AISC’S STEEL DESIGN GUIDE SERIES
3: “SERVICEABILITY DESIGN CONSIDERATIONS FOR LOW-RISE
BUILDINGS,” AND AS FOLLOWS:
A. LATERAL SWAY OF MAIN FRAMES AT EAVE HEIGHT: H/480 (WIND) &
H/50 (SEISMIC)
B. LATERAL SWAY OF MAIN FRAMES AT TOP OF MASONRY WALL: H/240
C. HORIZ DEFLECTION OF GIRTS SUPPORTING MASONRY OR CONCRETE
WALLS: L/600
METAL BUILDING SYSTEMS
D. HORIZ DEFLECTION OF GIRTS SUPPORTING METAL SIDING: L/180
E. VERTICAL DEFLECTION OF MAIN FRAME: L/240 (LIVE) & L/180 (TOTAL)
MAX
F. VERTICAL DEFLECTION OF PURLINS: L/180 (TOTAL)
G. LATERAL MOVEMENT OF ELEMENTS SUPPORTING DRYWALL
PARTITIONS (H= PARTITION HT): H/500
MB-3 WIND FORCES USED FOR COMPUTATION OF MEMBER STRESSES
ARE BASED ON ASCE 7, AND SHALL BE BASED ON THE 50 YEAR DESIGN
WIND EVENT. COMPUTE DEFLECTIONS DUE TO WIND USING THE 10 YEAR
DESIGN WIND EVENT.
MB-4 DESIGN THE METAL BUILDING SYSTEMS TO PROVIDE LATERAL
SUPPORT FOR THE TOP OF ALL MASONRY WALLS AND AT 4m ON CENTER (MAX) FOR WALLS EXCEEDING 4m IN HEIGHT. LATERAL SUPPORT SHALL
BE IN THE FORM OF A GIRT, SPANDREL BEAM OR OTHER APPROVED
MEANS. THE TOP OF THE MASONRY WALLS SHALL BE BOLTED TO THE
LATERAL SUPPORT. THE LATERAL SUPPORT SHALL BE CLIPPED TO THE
MAIN-FRAME COLUMNS WITH VERTICALLY SLOTTED CONNECTIONS.
MB-5 PRIOR TO FABRICATION, CONTRACTOR IS TO SUBMIT THE FOLLOWING
ITEMS TO THE CONTRACTING OFFICER FOR REVIEW. SUBMITTED ITEMS
MUST BE PREPARED BY, OR UNDER THE SUPERVISION OF, A
PROFESSIONAL ENGINEER REGISTERED IN ANY U.S. STATE OR
TERRITORY OR THE KINGDOM OF KUWAIT AND BEAR THE SEAL OF THAT
PROFESSIONAL ENGINEER.
A. SUBMIT ERECTION DRAWINGS TO INCLUDE DETAILS SHOWING
ERECTION AND ASSEMBLY OF THE METAL BUILDING SYSTEM
INCLUDING SIDE WALL, END WALL, MEZZANINE FRAMING, ROOF
CANOPY AND ROOF FRAMING. INCLUDE BUILDING TRANSVERSE AND
CROSS SECTIONS WITH ALL WIND AND SEISMIC BRACING PROPOSED
FOR THE BUILDING SYSTEM.
B. SUBMIT ANCHOR ROD PLACEMENT DRAWING TO SHOW ALL ANCHOR
ROD LOCATIONS. INCLUDE CALCULATED FOUNDATION LOADS AT THE
BASE OF ALL COLUMNS.
C. SUBMIT PANEL LAYOUTS ON WALLS, ROOF CANOPIES AND ROOFS.
SUBMIT DETAILS OF SUPPORTS ANCHORAGES AND SPECIAL
CONDITIONS. INCLUDE DETAILS OF PANEL PROFILES.
MB-6 CONTRACTOR IS TO ENGAGE AN EXPERIENCED INSTALLER TO ERECT
THE METAL BUILDING SYSTEMS WHO IS EXPERIENCED IN THE
ERECTION OF METAL BUILDINGS SIMILAR TO THAT REQUIRED FOR THIS
PROJECT AND WHO IS CERTIFIED IN WRITING BY THE METAL BUILDING
SYSTEM MANUFACTURER AS QUALIFIED FOR ERECTION OF THE
MANUFACTURER’S PRODUCTS.
MB-7 FABRICATE FRAMING COMPONENTS IN THE SHOP TO THE GREATEST
EXTENT POSSIBLE. IN GENERAL, SHOP WELD AND FIELD BOLT
CONNECTIONS.
MB-8 EXERCISE CARE IN DELIVERING, UNLOADING, STORING AND ERECTING
BUILDING MEMBERS, WALL AND ROOF COVERING PANELS AND OTHER
BUILDING COMPONENTS TO PREVENT BENDING, WARPING, TWISTING
AND SURFACE DAMAGE.
MB-9 ERECT FRAMING TRUE TO LINE, LEVEL AND PLUMB. LEVEL BASE PLATES
TO A TRUE PLANE WITH FULL BEARING TO SUPPORTING STRUCTURE;
USE A NON-SHRINKING GROUT TO OBTAIN UNIFORM BEARING AND TO
MAINTAIN A LEVEL BASE LINE ELEVATION.
MB-10 PROVIDE LATERAL LOAD RESISTING SYSTEMS AS REQUIRED TO RESIST
THE INDICATED WIND AND SEISMIC LOADS IN ROOF AND SIDE WALLS.
WHERE OVERHEAD DOORS INTERFERE WITH DIAGONAL BRACING,
PROVIDE STRUCTURAL WIND FRAMES. PROVIDE SAG RODS AS
REQUIRED TO MAINTAIN VERTICAL ALIGNMENT OF WALL GIRTS.
REFERENCE THE PLAN DRAWINGS FOR PERIMETER BRACING AND FRAME
LOCATIONS.
MB-11 PROVIDE FRAMED DOOR AND WINDOW OPENINGS OF PROPER DESIGN
AND SIZE TO ACCOMMODATE FINISHED UNITS AND TO TRANSMIT ALL
LOADS TO THE BUILDING STRUCTURE.
MB-12 THE FOUNDATION DESIGN ON THESE CONTRACT DRAWINGS IS
PRELIMINARY AND BASED UPON ASSUMED COLUMN BASE REACTIONS
CALCULATED BY A STRUCTURAL ENGINEER. THESE REACTIONS ARE
INDICATED IN A TABLE ON INDIVIDUAL BUILDING DRAWINGS. UPON
FINAL BUILDING DESIGN, THE ACTUAL COLUMN BASE REACTIONS ARE TO
BE COMPARED TO THE PRELIMINARY FOUNDATION DESIGN LOADS BY
THE GENERAL CONTRACTOR. IF THE ACTUAL REACTIONS EXCEED THE
PRELIMINARY DESIGN LOADS, THE FOUNDATION DESIGN PROVIDED IS
VOID AND A REGISTERED PROFESSIONAL ENGINEER MUST BE EMPLOYED
BY THE GENERAL CONTRACTOR TO COMPLETE A FOUNDATION DESIGN
BASED UPON THE ACTUAL REACTIONS.
A. COLUMN BASES ARE TO BE PINNED UNLESS NOTED OTHERWISE.
FIXED BASES ARE GENERALLY NOT PERMITTED UNO.
B. ANCHOR ROD DIAMETERS, AND SPACINGS ARE TO BE PROVIDED BY
THE MBS SUPPLIER AND COMPLY WITH THE FOOTING AND DETAILS
REFERENCED.
MB-13 THE GENERAL CONTRACTOR IS TO COORDINATE WITH THE MBS
MANUFACTURER AND MECHANICAL SUBCONTRACTORS TO PROVIDE
SUPPORT FOR ALL SUSPENDED EQUIPMENT, PIPING, DUCTWORK AND
UTILITIES IDENTIFIED ON THESE STRUCTURAL DRAWINGS, MEP
DRAWINGS, FIRE PROTECTING DRAWINGS, ARCHITECTURAL DRAWINGS,
OR OTHERWISE NOTED OR REQUIRED.
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
/1
/2
:4 :2
A
M
SS002
G E
N E
R A
L N
O T
E S
A L I A
L S
A L E
M A
B K
U W
A
IT
D O
L A
O N
IP
E
K U
N
M A
L J U
B O
O R
I
K C
H A
N S
A W
A T
J U
L Y
W
E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
R T
H O
M A
S K U
-5 -2
S T
D -S
S
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
IE
S
C D
C
MD-1 DECK, ACCESSORIES, AND ATTACHMENTS SHALL CONFORM TO THE
CURRENT EDITION OF ''STEEL DECK INSTITUTE SPECIFICATIONS''.
MD-2 PROVIDE SUPPORT AT COLUMNS AS REQUIRED FOR DECK
SUPPORT. PROVIDE L50x50x5 MINIMUM.
MD-3 AT OPENINGS IN DECK LESS THAN 300MMx300MM, PROVIDE A 16
GAUGE COVER PLATE FASTENED TO DECK WITH #12 METAL
SCREWS.
MD-4 AT CHANGE IN DECK DIRECTION, PROVIDE A 20 GAUGE x 230MM
WIDE CONTINUOUS PLATE. PROVIDE SAME PLATE AT ALL RIDGES,
VALLEYS, AND HIPS BENT TO MATCH PROFILE OF ROOF.
MD-5 ATTACH METAL DECK TO ROOF STRUCTURE AS REQUIRED FOR
EACH FACILITY AND NOTED ON SPECIFICATIONS SECTION 05 30 00.
METAL DECK
AA-1 INSTALL ONLY WHERE SPECIFICALLY SHOWN IN THE PROJECT
DETAILS.
AA-2 ALL POST-INSTALLED ADHESIVE ANCHOR TYPES SHALL BE
APPROVED BY THE CONTRACTING OFFICER AND SHALL HAVE A
CURRENT ICC-ESR THAT PROVIDES RELEVANT DESIGN VALUES TO
VALIDATE THE AVAILABLE STRENGTH.
AA-3 USE COMPRESSED AIR TO THOROUGHLY CLEAN THE ANCHOR
HOLES AND INSTALL ALL ANCHORS IN STRICT ACCORDANCE TO
THE ICC-ESR AND MANUFACTURER'S INSTRUCTIONS.
AA-4 WHEN INSTALLING DRILLED-IN-ANCHORS, USE CARE AND CAUTION
TO AVOID CUTTING OR DAMAGING THE EXISTING REINFORCING
BARS.
AA-5 SPECIAL INSPECTIONS SHALL BE IN ACCORDANCE WITH THE
REQUIREMENTS INDICATED IN THE SCHEDULE OF SPECIAL
INSPECTIONS IN SPECIFICATION SECTION 01 45 35.
AA-6 PROVIDE EPOXY ADHESIVE TYPE ANCHORS AS SHOWN IN THE
DRAWINGS WITH THE FOLLOWING MINIMUM STRENGTH
CAPACITIES AND MINIMUM EMBEDMENTS
ADHESIVE ANCHORS
ANCHOR
DIA. (mm)
MIN. EMBED
DEPTH (mm)
TENSION STRENGTH
(kN)
10 86 5.87
13 115 7.92
16 145 10.19
19 172 12.72
22 200 15.48
25 229 19.57
32 286 30.25
NOTES:
THE STRENGTH CAPACITIES ARE BASED ON MINIMUM EDGE
DISTANCES FOR A SINGLE ANCHOR AND f'c = 28MPA.
MIN. EDGE
DISTANCE (mm)
SCREW ANCHORS
SA-1 SCREW ANCHORS SHALL HAVE A CURRENT EVALUATION REPORT
ISSUED BY AN APPROVED SOURCE IN ACCORDANCE WITH ACI 355.2
AND/OR ICC-ES AC193 FOR CRACKED AND UNCRACKED CONCRETE.
SA-2 ANCHORS SHALL BE ZINC PLATED UNLESS SPECIFICALLY NOTED AS
GALVANIZED OR STAINLESS STEEL ON THE PLAN DETAILS.
SA-3 WHEN DETAILS OF SECTIONS INDICATE EXPANSION ANCHORS BUT
NO SIZE, PROVIDE ANCHORS WITH 3/4" (20mm) DIAMETER.
SA-4 ALL POST-INSTALLED SCREW ANCHOR TYPES SHALL BE APPROVED
BY THE CONTRACTING OFFICER AND SHALL HAVE A CURRENT ICC-
ESR THAT PROVIDES RELEVANT DESIGN VALUES TO VALIDATE THE
AVAILABLE STRENGTH.
SA-5 INSTALL ANCHORS IN ACCORDANCE WITH THE EVALUATION REPORT
AND MANUFACTURER'S RECOMMENDATIONS. PROVIDE THE
MINIMUM EMBEDMENT DEPTHS, SPACING AND EDGE DISTANCE
INDICATED IN THE SCHEDULE BELOW UNLESS NOTED OTHERWISE.
SA-6 WHEN INSTALLING DRILLED-IN-ANCHORS, USE CARE AND CAUTION
TO AVOID CUTTING OR DAMAGING THE EXISTING REINFORCING
BARS.
SA-7 SPECIAL INSPECTIONS SHALL BE IN ACCORDANCE WITH THE
REQUIREMENTS INDICATED IN THE SCHEDULE OF SPECIAL
INSPECTIONS IN SPECIFICATION SECTION 01 45 35.
SA-8 PROVIDE SCREW ANCHORS AS SHOWN IN THE DRAWINGS WITH THE
FOLLOWING MINIMUM STRENGTH CAPACITIES AND MINIMUM
EMBEDMENTS:
ANCHOR
DIA.
(mm [in])
NOMINAL
EMBED
DEPTH (mm)
MIN. SHEAR
STRENGTH
(kN)
6.35 [1/4] 50
9.52 [3/8] 75
12.70 [1/2] 90
15.87 [5/8] 100
19.05 [3/4] 130
NOTES:
THE STRENGTH CAPACITIES ARE BASED ON MINIMUM EDGE
DISTANCES FOR A SINGLE ANCHOR AND f'c = 28MPa.
MIN. EDGE
DISTANCE
(mm)
1.09
2.04
4.87
5.37
7.92
MIN.TENSION
STRENGTH
(kN)
2.33
3.56
7.07
7.12
10.2
SCREW ANCHORS (CONT'D)
AF-1 ALL POWDER ACTUATED FASTENERS SHALL BE APPROVED FOR TYPE,
APPLICATION AND INSTALLATION AND SHALL HAVE AN APPROVED ICC-
ES RESEARCH REPORT NUMBER.
AF-2 THE USE OF POWDER DRIVEN FASTENERS, IN TENSION, IS LIMITED TO
SUPPORT OF MINOR LOADS SUCH AS DRYWALL OR ACOUSTICAL
CEILINGS, DUCTWORK, CONDUIT, ETC. IN GENERAL, LOADS SHOULD BE
LIMITED TO LESS THAN 445N.
AF-3 FASTENERS SHALL NOT BE INSTALLED UNTIL THE CONCRETE HAS
REACHED ITS DESIGN STRENGTH.
AF-4 FASTENERS SHALL NOT BE INSTALLED IN CONCRETE WHERE THE
THICKNESS IS LESS THAN THREE TIMES THE PENETRATION REQUIRED.
AF-5 THE MINIMUM DISTANCE FROM THE EDGE OF CONCRETE TO CENTER
OF ANCHOR IS 90MM.
AF-6 FASTENERS IN THE UNDERSIDE OF CONCRETE ON METAL DECKING
SHALL BE PLACED IN THE HIGH FLUTE PORTION OF THE SLAB.
AF-7 WHEN INSTALLING POWDER DRIVEN PINS IN EXISTING NON-
PRESTRESSSED REINFORCED CONCRETE, USE CARE AND CAUTION TO
AVOID CUTTING OR DAMAGING THE EXISTING REINFORCING BARS.
POWDER ACTUATED FASTENERS
EXPANSION ANCHORS
EA-1 EXPANSION ANCHORS SHALL HAVE A CURRENT EVALUATION REPORT
ISSUED BY AN APPROVED SOURCE IN ACCORDANCE WITH ACI 355.2.
EA-2 ANCHORS SHALL BE ZINC PLATED UNLESS SPECIFICALLY NOTED AS
GALVANIZED OR STAINLESS STEEL ON THE PLAN DETAILS.
EA-3 WHEN DETAILS OF SECTIONS INDICATE EXPANSION ANCHORS BUT NO SIZE,
PROVIDE ANCHORS WITH 3/4" (20mm) DIAMETER.
EA-4 ALL POST-INSTALLED EXPANSION ANCHOR TYPES SHALL BE APPROVED BY
THE CONTRACTING OFFICER AND SHALL HAVE A CURRENT ICC-ESR THAT
PROVIDES RELEVANT DESIGN VALUES TO VALIDATE THE AVAILABLE
STRENGTH.
EA-5 INSTALL ANCHORS IN ACCORDANCE WITH THE EVALUATION REPORT AND
MANUFACTURER'S RECOMMENDATIONS. PROVIDE THE MINIMUM
EMBEDMENT DEPTHS, SPACING AND EDGE DISTANCE INDICATED IN THE
SCHEDULE BELOW UNLESS NOTED OTHERWISE.
EA-6 WHEN INSTALLING DRILLED-IN-ANCHORS, USE CARE AND CAUTION TO AVOID
CUTTING OR DAMAGING THE EXISTING REINFORCING BARS.
EA-7 SPECIAL INSPECTIONS SHALL BE IN ACCORDANCE WITH THE
REQUIREMENTS INDICATED IN THE SCHEDULE OF SPECIAL INSPECTIONS IN
SPECIFICATION SECTION 01 45 35.
EA-8 TEST INSTALLED ANCHORS IN ACCORDANCE WITH THE ANCHOR SCHEDULE
AND AS FOLLOWS:
a. EXPANSION ANCHORS SHALL BE TESTED WITH A CALIBRATED TORQUE
WRENCH. THE TORQUE LISTED BELOW SHALL BE OBTAINED WITHIN 1/2 TURN
OF THE NUT.
b. TESTING SHALL BE DONE IN THE PRESENCE OF SPECIAL INSPECTOR.
ANCHORS TESTED SHALL BE SELECTED AT RANDOM BY THE SPECIAL
INSPECTOR. THE TEST FREQUENCY SHALL BE AS FOLLOWS:
- 100% OF ALL ANCHORS USED FOR STRUCTURAL APPLICATIONS.
- 50% OF ANCHORS OR ALTERNATE BOLTS IN A GROUP USED FOR NON
STRUCTURAL APPLICATIONS SUCH AS EQUIPMENT ANCHORAGE. INCLUDE
AT LEAST ONE HALF THE ANCHORS IN EACH GROUP.
- 10% OF ANCHORS USED FOR SILL PLATE BOLTING.
- 10% OF ANCHORS WHERE THE FACTORED DESIGN TENSION LOAD IS LESS
THAN 445N AND IS CLEARLY IDENTIFIED ON THE PLANS OR DETAIL.
- IF ANY ANCHOR FAILS, ALL OF THE SAME TYPE SHALL BE TESTED, WHICH
ARE INSTALLED BY THE SAME TRADE, NOT PREVIOUSLY TESTED UNTIL
TWENTY CONSECUTIVE ANCHORS PASS, THEN RESUME THE INITIAL TESTING
FREQUENCY
of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
/1
/2
:4 :2
A
M
SS003
G E
N E
R A
L N
O T
E S
A L I A
L S
A L E
M A
B K
U W
A
IT
D O
L A
O N
IP
E
K U
N
M A
L J U
B O
O R
I
K C
H A
N S
A W
A T
J U
L Y
W
E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
R T
H O
M A
S K U
-5 -2
S T
D -S
S
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
IE
S
C D
C
EXPANSION ANCHORS (CONT'D)
ANCHOR DIA.
(mm)
MIN. EMBED
DEPTH (mm)
MIN. EDGE
DISTANCE (mm)
MIN. SPACING
(mm)
INSTALLATION
TORQUE (M-N)
EXPANSION ANCHOR SCHEDULE INSTALLED IN CONCRETE OR IN
TOP OF CONCRETE-FILLED STEEL DECK (f'c = 28MPa MIN.)
NOTES:
• DO NOT INSTALL 16mm DIA. EXPANSION ANCHORS IN UPPER FLUTE.
• LOWER FLUTE WIDTH MUST BE 105mm, MIN.
• CENTERLINE OF ANCHOR IS OFFSET FROM CENTERLINE OF FLUTE 25mm MAX.
NOTES:
• DO NOT INSTALL 16mm DIA. EXPANSION ANCHORS IN UPPER FLUTE.
c. TEST EQUIPMENT SHALL BE CALIBRATED BY AN APPROVED TESTING LABORATORY IN
ACCORDANCE STANDARD RECOGNIZED PROCEDURES.
SB-1 BRACING AND SUPPORT OF ALL DUCTS, PIPES, CONDUITS, FIRE SPRINKLER, AND OTHER
SYSTEMS SHALL MEET CURRENT CODE. THE DESIGN OF THE SUPPORT AND BRACING
SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR WITH THE CONTRACTOR USING
ANY PREAPPROVED SYSTEM.
SB-2 FIRE SPRINKLERS SHALL MEET THE CURRENT VERSION OF NFPA-13. BRACES SHALL BE
LOCATED WITHIN 150mm OF THE HANGER AND ROD STIFFENERS SHALL BE ADDED AT
BRACE LOCATIONS WHEN THE LENGTH OF THE ROD EXCEEDS 50 TIMES ITS DIAMETER.
SB-3 PRE-APPROVED SYSTEMS MAY BE USED SUBJECT TO APPROVAL OF THE CONTRACTING
OFFICER.
SB-4 THE CONTRACTOR IS REQUIRED TO PROVIDE SHOP DRAWINGS AND CALCULATIONS
SHOWING ALL BRACING AND SUPPORT LOCATIONS AND DETAILS OF CONNECTION FOR ALL
SYSTEMS INCLUDING SMACNA, FIRE SPRINKLERS AND OTHER PREAPPROVED SYSTEMS.
THE SPECIFIC DETAIL FOR EACH TYPE OF CONNECTION MUST BE REFERENCED ON THE
SHOP DRAWING PLANS. SUPPLYING A BOOK OF DETAILS WITHOUT REFERENCING THE
PROPER DETAIL TO A SPECIFIC LOCATION ON THE PLANS IS NOT ACCEPTABLE. THIS
SUBMITTAL SHALL BE REVIEWED BY THE CONTRACTING OFFICER.
SB-4 WHERE PRE-APPROVED SYSTEMS DO NOT ADDRESS THE GIVEN CONDITION, THE
CONTRACTOR IS RESPONSIBLE FOR AN INDEPENDENTLY ENGINEERED SYSTEM. THIS
SYSTEM SHALL BE DESIGNED BY A LICENSED STRUCTURAL ENGINEER REGISTERED IN THE
STATE OF CONSTRUCTION WITH CALCULATIONS AND DETAILS PROVIDED FOR REVIEW BY
THE CONTRACTING OFFICER.
SEISMIC BRACING OF ELECTRICAL AND MECHANICAL
SYSTEMS AND FIRE SPRINKLERS
ANCHOR DIA.
(mm)
MIN. EMBED
DEPTH (mm)
MIN. EDGE
DISTANCE (mm)
MIN. SPACING
(mm)
INSTALLATION
TORQUE (M-N)
EXPANSION ANCHOR SCHEDULE INSTALLED IN SOFFIT OF
CONCRETE (f'c = 28MPa MIN.) OVER PROFILE STEEL DECK
COLD-FORMED FRAMING
CF-1 CONTRACTOR SHALL ELECTRONICALLY SUBMIT COLD-FORMED SHOP DRAWINGS WITH
STRUCTURAL CALCULATIONS STAMPED BY A LICENSED PROFESSIONAL ENGINEER
REGISTERED IN IN ANY ONE OF THE 50 UNITED STATES OF AMERICA OR ITS TERRITORIES
OR CERTIFIED BY A SIMILAR RECOGNIZED PROFESSIONAL ORGANIZATION TO GOVERNMENT
FOR APPROVAL. CONTRACTOR SHALL REVIEW AND STAMP ALL SHOP DRAWINGS BEFORE
SUBMITTING TO THE ARCHITECT.
CF-2 SHOP DRAWING SUBMISSIONS SHALL INCLUDE THE FOLLOWING INFORMATION:
THE NAME, ADDRESS, PHONE NUMBER, & FAX NUMBER OF THE SUPPLIER.
ALL DESIGN LOADS.
PLANS & ELEVATIONS KEYING IN ALL SECTIONS.
CONNECTION DETAILS SPECIFYING ALL FASTENER TYPES, QUANTITY, & LOCATIONS.
ALL REQUIRED BRIDGING, BRACING, & OTHER COLD-FORMED COMPONENTS.
CF-3 MINIMUM COLD-FORMED GAUGE SHALL NOT BE LESS THAN 18 GA. ALL MEMBERS SPECIFIED
ON THE CONSTRUCTION DOCUMENTS ARE MINIMUM SIZES.
CF-4 REFER TO SPECIFICATIONS FOR COLD-FORMED METAL FRAMING YIELD STRESS (Fy).
CF-5 ALL COLD-FORMED MEMBERS SHALL BE GALVANIZED.
CF-6 DESIGN, SUPPLY, AND INSTALL ANY HOT-ROLLED OR COLD-ROLLED SECTION NEEDED TO
PROVIDE A COMPLETE EXTERIOR CLADDING SYSTEM OR INTERIOR WALLS SYSTEM.
CF-7 REFER TO SPECIFICATIONS 05 40 00 FOR DEFLECTION LIMIT CRITERIA FOR ALL COLD-
FORMED FRAMING DEFLECTION.
CF-8 ALL WELDING SHALL BE AWS D1.3. WELDERS SHALL BE CERTIFIED FOR THE THICKNESS OF
MATERIAL BEING WELDED.
CF-9 SCREW PENETRATION THROUGH JOINED MATERIALS SHALL NOT BE LESS THAN THREE
EXPOSED SCREW THREADS. REFER TO INSTALLATION INSTRUCTIONS OF THE SCREW
MANUFACTURER AND/OR ASTM C-954 FOR MINIMUM SPACING AND EDGE DISTANCE AND
TORQUE REQUIREMENTS.
CF-10 INSTALL CONTINUOUS TRACKS SIZED TO MATCH STUDS. ALIGN TRACKS ACCURATELY TO
LAYOUT AT BASE AND TOPS OF STUDS. SECURE TRACKS AS RECOMMENDED BY STUD
MANUFACTURER FOR TYPE OF CONSTRUCTION INVOLVED, EXCEPT DO NOT EXCEED 24'' o/c SPACING FOR POWDER DRIVEN FASTENERS, OR 16'' o/c FOR OTHER TYPES OF
ATTACHMENT. PROVIDE FASTENERS AT CORNERS AND END OF TRACKS.
CF-11 WHERE SPLICING OF TRACK IS NECESSARY BETWEEN STUD SPACING, PROVIDE A PIECE OF
STUD PLACED BETWEEN ADJACENT TRACKS AND FASTENED BY WELD OR SCREW TO EACH
SIDE OF THE TRACK EACH END.
CF-12 AT NON-LOAD BEARING WALLS, PROVIDE A SLIP TRACK AT TOP OF WALL.
CF-13 FASTENING OF COMPONENTS SHALL BE WITH SELF-DRILLING SCREWS OR BY WELDING.
SCREWS AND WELDS SHALL BE SUFFICIENT SIZE TO ENSURE THE STRENGTH OF THE
CONNECTION.
CF-14 ALL WELDS SHALL BE TOUCHED UP WITH ZINC-RICH PAINT.
CF-15 INSTALL COLD-FORMED FRAMING MEMBERS IN ACCORDANCE WITH MANUFACTURER'S
PRINTED OR WRITTEN INSTRUCTIONS AND RECOMMENDATIONS UNLESS NOTED
OTHERWISE.
CF-16 FIELD CUTTING OF COLD-FORMED MEMBERS SHALL BE BY SAW OR SHEAR. TORCH CUTTING
IS NOT PERMITTED.
CF-17 TEMPORARY BRACING OF COLD-FORMED MEMBERS SHALL BE PROVIDED AND REMAIN IN
PLACE UNTIL WORK IS PERMANENTLY STABILIZED. ALL BRACING REQUIRED SHALL BE
DESIGNED AND SUPPLIED BY THE COLD-FORMED CONTRACTOR.
COLD-FORMED FRAMING (CONT'D)
NOTES AND DETAILS FROM SHEETS SS001 TO SS601 MUST APPLY TO ALL FACILITIES WHERE
APPLICABLE OR WHEN REFERENCED IN THE DRAWINGS FOR EACH FACILITY, EXCEPT FOR ALERT
MAGAZINE.
STANDARD DETAILS APPLICABILITY
- SPAN DIRECTION
- STEEL MOMENT CONNECTION
- STEP IN SLAB
- RECESS IN SLAB
- OPENING IN FLOOR/ROOF
- EARTH
- GRAVEL
- GROUT/SAND
- STEEL
- BEARING WALL
- CMU WALL
CMU
- VOID FORM
(FRONT VIEW)
OPEN
- DEPRESSION IN FOUNDATION WALL
- VOID FORM
(SECTION VIEW)
BRG WALL
NO HATCH
- ELEVATION SYMBOL
F
A
R
(N)
L-PS (E)
T
B O
T H
S
ID
E S
A R
R O
W S
ID
E
O P
P O
S
IT
E S
ID
E
FIELD WELD SYMBOL
(FLAG ALWAYS POINTS TOWARD REAR
OF WELD SYMBOL)
WELD ALL AROUND
SYMBOL
ARROW CONNECTING REFERENCE LINE TO
ARROW SIDE MEMBER
OF JOINT OR ARROW SIDE OF JOINT
REFERENCE
LINE
SPECIFIC PROCESS OR
OTHER REFERENCE
NUMBER OF SPOT OR
PROJECTION WELDS
PITCH (CENTER TO CENTER
SPACING) OF WELD
LENGTH OF WELD
GROOVE ANGLE, INCLUDED ANGLE OF
COUNTERSINK FOR PLUG WELDS
FINISH SYMBOL
EFFECTIVE THROAT
ROOT OPENING DEPTH
OF FILLING FOR PLUG
AND SPOT WELDS
CONTOUR SYMBOLS
DEPTH OF PREPARATION; SIZE OR
STRENGTH FOR CERTAIN WELDS
TAIL (TAIL IS
OMITTED WHEN
REFERENCE IS
NOT USED)
- CONCRETE
J SQUARE WELD BEVEL V FLARE-V FLARE BEVEL
ARROW SIDE
OPPOSITE SIDE
U
GROOVE WELDS
SEAM WELDFILLET WELD FLANGE CORNER
ARROW SIDE
OPPOSITE SIDE
PLUG WELD SURFACE WELD FLANGE END BACKINGSTUD WELD SPOT OR
PROJECTION WELD
BACK OR
BACKING WELD
SLOT WELD
BASIC WELD SYMBOL OR
DETAIL REFERENCE
WELD SYMBOLS SHALL BE CONTAINED WITHIN
THE LENGTH OF THE REFERENCE LINE.
ELEMENTS IN THIS AREA REMAIN AS SHOWN
WHEN THE TAIL AND ARROW ARE REVERSED
SYMBOLS AND ABBREVIATIONS
1 a
HATCH PATTERNS SYMBOLS
WELDING SYMBOL DIAGRAM
WELD SYMBOLS
VIEW IDENTIFICATION NUMBER
VIEW NAME
DIRECTION OF VIEW
SECTION IDENTIFICATION
NUMBER
CALLOUT AREA VIEW
X
RE: X-XXX RE: X-XXX
GRID LINE
VIEW NAME
X/X":1'-0"
X-101
DRAWING SHEET MATCHING
REFERENCE NUMBER
GRID IDENTIFICATION
(ALPHA OR NUMERIC)
DETAIL SHEET
REF NUMBER
CALLOUT VIEW
IDENTIFICATION
NUMBER
DETAIL SHEET
REF NUMBER
VIEW SCALE
X-101
REVISION CLOUD
REVISION & AMENDMENT
CLOUD AND SYMBOL
REVISION IDENTIFICATION
SYMBOL (NUMERIC)
AMENDMENT IDENTIFICATION
SYMBOL (ALPHA)
DRAWING SHEET SYMBOLS
VIEW TITLE SYMBOL SECTION CUT SYMBOL
CALLOUT SYMBOL
GRID SYMBOL
MATCHLINE SYMBOLGRAPHIC BAR SCALE SYMBOL
DIRECTION
OF MAGNETIC
NORTH
NORTH SYMBOLS
TYPICAL
NORTH
PLAN
NORTH
SCALE:
MATCHLINE MATCHLINE
# - PLAN KEYNOTES
- INDICATES DEPRESSED SLAB
#4 @ 8" (T)
- AREA REINF
PLAN NORTHPLAN NORTH
US Army Corps of Engineers®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
IS
O
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
UNLESS OTHERWISE NOTED, LINEAR
DIMENSIONS SHOWN ARE IN MILLIMETERS.
P L O
T D
A T
E
F
IL
E N
A M
E
M
ID
D L E
E A
S T
D
IS
T R
IC
T
G
H
I
J
K
L
M
N
O
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
P
R
IN
C E
F R
E D
E R
IC
K
D R
IV
E
W
IN
C H
E S
T E
R V
A
/1
/2
:4 :2
A
M
SS004
S T
R U
C T
U R
A L
A B
B R
E V
A T
IO
N
S A
N D
S Y
M B
O L
S
A L I A
L S
A L E
M A
B K
U W
A
IT
D O
L A
O N
IP
E
K U
N
M A
L J U
B O
O R
I
K C
H A
N S
A W
A T
J U
L Y
W
E
R R
A
K M
O D
K
U W
A
IT
A
IR
F O
R C
E
K U
-5 -2
R T
H O
M A
S K U
-5 -2
S T
D -S
S
K U
W A
IT
A
P A
C H
E A
L E
R T
F A
C
IL
IT
IE
S
C D
C
# NUMBER
& AND
= EQUAL, EQUALS
@ AT
A/C AIR CONDITIONING
AB ANCHOR BOLT
ACI AMERICAN CONCRETE INSTITUTE
ADDL ADDITIONAL
ADJ ADJACENT
AFF ABOVE…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .