UD_2.4_PACKAGE_1_LSA_DRAWINGS_AM004_04_APR_18.pdf

PDF 98 KB Posted

Attached to
Construct Critical Infrastructure Federal contract opportunity
Solicitation number
W912ER-18-R-0004
Issued by
Department of the Army Materiel Command Contracting Command Detroit Arsenal

About this file

Drawings

View the file

Other files for this federal contract opportunity

Other files attached to Construct Critical Infrastructure, newest first.
File Type Posted
AM5_Specifications_6_Apr_18.pdf PDF
UD_2.4_PACKAGE_1_LSA_DRAWINGS2_AM005_06_APR_18.pdf PDF
UD_2.4_PACKAGE_1_LSA_DRAWINGS1_AM005_06_APR_18.pdf PDF
W912ER18R0004-0005.pdf PDF
AM4_Specifications_4_Apr_18.pdf PDF
W912ER18R0004-0004.pdf PDF
W912ER18R0004-0003.pdf PDF
AM3_Specifications_29_Mar_18.pdf PDF
AM2_UD_2.4_-_Pkg_1_LSA_-_Cost_Breakdown_3-26-18_-_NO_COST_-_.pdf PDF
AM2_Specifications_26_Mar_18.pdf PDF
AM2_UD_2.4_-_Pkg_1_LSA_Bid_Schedule_-_3-26-18__.pdf PDF
W912ER18R0004-0002.pdf PDF
UD_2.4_PACKAGE_1_LSA_DRAWINGS_AM002_26_MAR_18.pdf PDF
AM1_UD_2.4_-_Package_1_Pkg_1_LSA__Cost_Breakdown_3-13-18.pdf PDF
AM1_Specifications_13_Mar_18.pdf PDF
W912ER-18-R-0004-01_Conformed_Copy.pdf PDF
UD_2.4_PACKAGE_1_LSA_DRAWINGS_AM001_15_MAR_18.pdf PDF
W912ER-18-R-0004-01_Modificaion.pdf PDF
Volume_1_Attachment_A.pdf PDF
Volume_1_Attachment_B.pdf PDF
Volume_1_Attachment_D.xls XLS spreadsheet
Volume_1_of_3_Solicitation.pdf PDF
Volume_1_Attachment_C.pdf PDF
Volume_2_of_3_Specs_Div_01-12_8_Feb_18.pdf PDF
Volume_3_of_3_Specs_Div_13-44_5_Feb_18.pdf PDF
&_1575;&_1604;&_1602;&_1610;&_1575;&_1583;&_1607;_&_1575;&_1604;&_1593;&_1575;&_1605;&_1607;_&_1604;&_1604;&_1602;&_1608;&_1575;&_1578;_&_1575;&_1604;&_1605;&_1587;&_1604;&_1581;&_1607;_&_1575;&_1604;&_1575;&_1585;&_1583;&_1578;&_1610;&_1607;_(2)RJAF_Upda PDF
Copy_of_332_AEW_Vetting_Request_Worksheet_TEMPLATE.xlsx XLSX spreadsheet
Jordanian_Information_Form.pdf PDF
RJAF_DMS_Application_Blank.pdf PDF
U.S._Contractor_Request_Template.xlsx XLSX spreadsheet
Show all 30

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M

AR

K D

ES

C

R

IP

TI

O

N

PL

O

T D

AT

E:

FI

LE

N

AM

E:

X:\REVIT PROJECTS\JORDAN\2017\JR-463243 - MUWAFFAQ-SALTI AIR BASE (MSAB)\PACKAGE 1\JR-463243 - GENERAL PACKAGE 1\JR-463243 - GENERAL PACKAGE 1 AM#4.rvt

4/4/2018 7:33:30 AM

4/ 4/

:3

3:

AM

G-012

IN

D

EX

O

F D

R

AW

IN

G

S

JO

R

D

AN

G W

D

G W

D

SW

T

U D

.4

PA

C

KA

G E

P2 -4

D

AV

ID

S

. C

LA

R K

JR

-4

3- G

I0

G N

G

EN

ER

AL

M

ID

D

LE

E

AS

T D

IS

TR

IC

T

P.

O

. B O

X

W

IN

C

H

ES

TE

R

,V A

4-

JR-463243E - GUARD HOUSE

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

GENERAL

G-001 JR-463243E-G001IS COVER SHEET

STRUCTURAL

S-101 JR-463243E-S101PN FOUNDATION PLAN

S-102 JR-463243E-S102PN ROOF FRAMING PLAN

ARCHITECTURAL

A-101 JR-463243E-A101PN 2 AM#2 FLOOR, ROOF ,REFLECTED CEILING PLAN & LIFE

SAFTY ANALYSIS

A-201 JR-463243E-A201EL ELEVATIONS

A-301 JR-463243E-A301SE BUILDING & WALL SECTIONS & DOOR SCHEDULE

A-601 JR-463243E-A601SC DOORS AND WINDOW TYPES AND SCHEDULES

INTERIORS

I-101 JR-463243E-IF101PN FURNITURE PLAN & FINISH SCHEUDLE

MECHANICAL

M-101 JR-463243E-MH101PN HVAC FLOOR PLAN

ELECTRICAL

E-101 JR-463243E-EP101PN 1 AM#1 POWER, LIGHTING, GROUNDING AND LIGHTNING

PROTECTION PLANS

TELECOMMUNICATIONS

T-101 JR-463243E-T101PN TELECOM FLOOR & DETAILS PLAN

T-601 JR-463243E-T601DI TELECOM ONE-LINE DIAGRAM

INDEX OF DRAWINGS

JR-463243F - ITN

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

GENERAL

G-001 JR-463243F-G001IS COVER SHEET

STRUCTURAL

S-101 JR-463243F-S101PN FOUNDATION PLAN

S-102 JR-463243F-S102PN ROOF FRAMING PLAN

ARCHITECTURAL

A-001 JR-463243F-A001PN LIFE SAFTY ANALYSIS

A-101 JR-463243F-A101PN 2 AM#2 FLOOR PLAN, RCP & ROOF PLAN

A-201 JR-463243F-A201EL ELEVATIONS

A-301 JR-463243F-A301SE BUILDING & WALL SECTIONS

A-601 JR-463243F-A601SC 2 AM#2 DOORS TYPES AND SCHEDULE

INTERIORS

I-601 JR-463243F-IF601SC INTERIOR FINISH SCHEDULE

FIRE PROTECTION

F-001 JR-463243F-F001GN FIRE ALARM SYMBOLS, GENERAL NOTES, AND

DETAILS

F-002 JR-463243F-F002GN FIRE ALARM/MNS SEQUENCE OF OPERATIONS

F-101 JR-463243F-F101PN FIRE PROTECTION PLAN

F-501 JR-463243F-F601DT FIRE ALARM DETAILS

F-601 JR-463243F-F601DI FIRE ALARM/MNS-RISER DIAGRAM

MECHANICAL

M-101 JR-463243F-MH101PN HVAC FLOOR PLAN

M-301 JR-463243F-MH301SE HVAC SECTIONS

ELECTRICAL

E-101 JR-463243F-EP101PN 1 AM#1 POWER AND LIGHTING PLANS

E-102 JR-463243F-E102PN 1 AM#1 GROUNDING AND LIGHTNING PROTECTION PLANS

E-601 JR-463243F-E601SC 1 AM#1 ELECTRICAL PANEL SCHEDULES

TELECOMMUNICATIONS

T-101 JR-463243F-T101PN TELECOM FLOOR PLAN

T-102 JR-463243F-T102PN TELECOM CABLE LADDER PLAN

JR-463243G - PUMP HOUSE

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

GENERAL

G-001 JR-463243G-G001IS COVER SHEET

STRUCTURAL

S-101 JR-463243G-S101PN FOUNDATION PLAN

S-102 JR-463243G-S101PN ROOF FRAMING PLAN

ARCHITECTURAL

A-001 JR-463243G-A001PN LIFE SAFTY ANALYSIS

A-101 JR-463243G-A101PN 2 AM#2 FLOOR, ROOF, REFLECTED CEILING & LIFE SAFETY

PLANS

A-201 JR-463243G-A201EL ELEVATIONS

A-301 JR-463243G-A301SE BUILDING & WALL SECTIONS & DOOR SCHEDULE

A-401 JR-463243G-S101DT INTERIOR DETAILS

A-601 JR-463243G-A601SC DOORS AND WINDOW TYPES AND SCHEDULES

INTERIORS

I-601 JR-463243G-IF601SC INTERIOR FINISH SCHEDULE

FIRE PROTECTION

F-001 JR-463243G-F001GN FIRE ALARM SYMBOLS, GENERAL NOTES, AND

DETAILS

F-002 JR-463243G-F002GN FIRE ALARM/MNS SEQUENCE OF OPERATIONS

F-101 JR-463243G-F101PN FIRE PROTECTION PLAN

F-102 QA-463243G-F101PN FIRE PROTECTION SPRINKLER COVERAGE PLAN

F-501 JR-463243G-F501DT FIRE ALARM DETAILS

F-502 JR463243G-F502DT SPRINKLER RISER DETAIL

F-601 JR-463243G-F601DI FIRE ALARM/MNS-RISER DIAGRAM

PLUMBING

P-101 JR-463243G-P101PN PLUMBING PLAN

MECHANICAL

M-101 JR-463243G-MH101PN HVAC FLOOR PLAN

ELECTRICAL

E-101 JR-463243G-EP101PN POWER, LIGHTING, GROUNDING AND LIGHNTING

PROTECTION PLANS

E-102 JR-463243G-EP102PN LIGHTNING PROTECTION PLAN AND PANEL LP

TELECOMMUNICATIONS

T-101 JR-463243G-T101PN TELECOM FLOOR PLAN

T-601 JR-463243G-T-601DI TELECOM ONE-LINE DIAGRAM

JR-463243$ - STANDARDS

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

GENERAL

SG-001 JR-463243$-SG001GN COVER SHEET

STRUCTURAL

SS-001 JR-463243$-SS001GN GENERAL NOTES

SS-002 JR-463243$-SS002GN CONCRETE NOTES

SS-003 JR-463243$-SS003GN MASONRY NOTES

SS-301 JR-463243$-SS301SE FOUNDATION SECTIONS

SS-302 JR-463243$-SS302SE FRAMING SECTIONS

SS-501 JR-463243$-SS501DT TYPICAL DETAILS

SS-502 JR-463243$-SS502DT TYPICAL DETAILS

SS-503 JR-463243$-SS503DT TYPICAL DETAILS

SS-504 JR-463243$-SS504DT TYPICAL DETAILS

SS-505 JR-463243$-SS505DT TYPICAL DETAILS

ARCHITECTURE

SA-501 JR-463243$-SA502DT WALL DETAILS

SA-502 JR-463243$-SA506DT WINDOW & LOUVER DETAILS

SA-503 JR-463243$-SA507DT DOOR DETAILS

SA-504 JR-463243$-SA503DT MISCELLANEOUS DETAILS

PLUMBING

SP-001 JR-463243$-SP001GN GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS

SP-501 JR-463243$-SP501DT PLUMBING DETAILS

SP-502 JR-463243$-SP502DT PLUMBING DETAILS

MECHANICAL

SM-001 JR-463512A-M001GN GENERAL NOTES, ABBREVIATIONS AND SYMBOLS

SM-002 JR-463512A-M002GN SEQUENCE OF OPERATIONS - ITN

SM-501 JR-463512A-M501DT MECHANICAL DETAILS

SM-502 JR-463512A-M502DT MECHANICAL DETAILS

SM-503 JR-463512A-M503DT MECHANICAL DETAILS

SM-504 JR-463512A-M504DT MECHANICAL DETAILS

SM-601 JR-463512A-M602SC HVAC REGISTER SCHEDULES

ELECTRICAL

SE-001 JR-463243$-SE001GN 1 AM#1 GENERAL LEGEND AND ABBREVIATIONS

SE-501 JR-463243$-SE501DT 1 AM#1 TYPICAL LIGHTING DETAILS

SE-502 JR-463243$-SE502DT 1 AM#1 TYPICAL LIGHTING DETAILS

SE-503 JR-463243$-SE503DT 1 AM#1 TYPICAL LIGHTING DETAILS

SE-504 JR-463243$-SE504DT TYPICAL ELECTRICAL DETAILS

SE-505 JR-463243$-SE505DT 1 AM#1 ELECTRICAL SITE DETAILS

SE-506 JR-463243$-SE506DT 2 AM#2 ELECTRICAL SITE DETAILS

TELECOMMUNICATIONS

ST-001 JR-463243$-ST001DT TELECOM STANDARDS LEGEND

ST-501 JR-463243$-ST501DT TELECOM STANDARD DETAILS

ST-502 JR-463243$-ST502DT TELECOM STANDARD DETAILS

ST-503 JR-463243$-ST503DT TELECOM STANDARD DETAILS

ST-504 JR-463243$-ST504DT TELECOM STANDARD DETAILS

ST-505 JR-463243$-ST505DT TELECOM STANDARD DETAILS

FACILITIES JR-463243A THROUGH JR-463243D ARE NOT PART OF THIS CONTRACT SET.

AM

EN

D

M

EN

T #1

-1

2- 1 8

AM

EN

D

M

EN

T #2

-2

2- 1 8

AM

EN

D

M

EN

T #4

-0

4- 1 8

JR-463243I - FIRE PUMP HOUSE

SHT. REF.

NO. FILE NO

REVISIONS

TITLEREV. NO. AM/COP NO.

GENERAL

G-001 JR-463243I-G001IS COVER SHEET

STRUCTURAL

S-101 JR-463243I-S101PN FOUNDATION PLAN

S-102 JR-463243I-S101PN ROOF FRAMING PLAN

ARCHITECTURAL

A-001 JR-463243F-A001PN LIFE SAFTY ANALYSIS

A-101 JR-463243I-A101PN 2 AM#2 FLOOR & ROOF PLANS

A-102 JR-463243I-A102PN REFLECTED CEILING PLAN

A-201 JR-463243I-A201EL ELEVATIONS

A-301 JR-463243I-A301SE BUILDING & WALL SECTIONS & DOOR SCHEDULE

A-401 JR-463243I-S101DT INTERIOR DETAILS

A-601 JR-463243I-A601SC DOORS AND WINDOW TYPES AND SCHEDULES

INTERIORS

I-601 JR-463243I-IF601SC4 4 AM#4 INTERIOR FINISH SCHEDULE

FIRE PROTECTION

F-001 JR-463243I-F001GN FIRE ALARM SYMBOLS, GENERAL NOTES, AND

DETAILS

F-002 JR-463243I-F002GN FIRE ALARM/MNS-SEQUENCE OF OPERATIONS

F-101 JR-463243I-F101PN FIRE PROTECTION PLAN

F-102 QA-463243I-F102PN FIRE PROTECTION SPRINKLER COVERAGE PLAN

F-501 JR-463243I-F501DT FIRE ALARM/MNS DETAILS

F-502 JR-463243I-F502DT SPRINKLER RISER DETAIL

F-601 JR-463243I-F601DI FIRE ALARM/MNS-RISER DAIGRGAM

PLUMBING

P-101 JR-463243I-P101PN PLUMBING PLAN

MECHANICAL

M-101 JR-463243I-MH101PN HVAC FLOOR PLAN

ELECTRICAL

E-101 JR-463243I-EP101PN 2 AM#2 POWER, LIGHTING, GROUNDING AND LIGHNTING

PROTECTION PLANS

E-102 JR-463243I-EP102PN 1 AM#1 LIGHTNING PROTECTION PLAN AND PANEL LP

TELECOMMUNICATIONS

T-101 JR-463243I-T101PN TELECOM FLOOR PLAN

T-601 JR-463243I-T-601DI TELECOM ONE-LINE DIAGRAM

FACILITY JR-463243H IS NOT PART OF THIS CONTRACT SET.

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E

File Path:

Plot Date:

M

AR

K D

ES

C

R

IP

TI

O

N

PL

O

T D

AT

E:

FI

LE

N

AM

E:

C:\Users\n0tamdlh\Documents\JR-463243I - FIRE PUMP HOUSE - PACKAGE 1 AM#4_n0tamdlh.rvt

4/3/2018 3:14:21 PM

4/ 3/

:1

4:

PM

I-601

IN

TE

R

IO

R F

IN

IS

H S

C H

ED

U

LE

JO

R

D

AN

D . H

AR

D

Y

D . H

AR

D

Y

M . C

AR

TE

R

Is su e D at e

U D

.4

PA

C

KA

G E

P2 -4

I

JE

FF

ER

Y

P.

R

AN

EY

JR

-4

3I

-IF

1S

C

FI

R

E

PU

M P

HO

U

SE

M

ID

D

LE

E

AS

T D

IS

TR

IC

T

P.

O

. B O

X

W

IN

C

H

ES

TE

R

,V A

4-

SCHEDULE - INTERIOR MATERIAL & COLOR BASIS OF DESIGN

FINISH DESCRIPTION MANUFACTURER STYLE COLOR COMMENTS ALTERNATE MANUFACTURERS

C1 CONCRETE FLOOR SEALER SHERWIN WILLIAMS H&C CONCRETE & DRIVEWAY PROTECTOR CLEAR 1 COAT STONE TECHNOLOGIES, V-SEAL

C2 FLOOR COATING - EPOXY TRAFFIC

COATING

SHERWIN WILLIAMS ARMORSEAL 1000HS WITH SHARKGRIP

NONSKID ADDITIVE

CLEAR SEVERE INDUSTRIAL EPOXY

URETHANE SYSTEM (3 COAT

SYSTEM WITH SHARKGRIP)

MAINTENANCE BAYS, STORAGE,

VEHICLE PARKING

STONE TECHNOLOGIES, V-SEAL

P2 CEILING PAINT JOTUN (TO MATCH SHERWIN WILLIAMS) FLAT FINISH JOTUN S 0500-N TO MATCH HIGH

REFLECTIVE WHITE 7757

SHERWIN WILLIAMS, BENJAMIN

MOORE

P3 WALL PAINT JOTUN (TO MATCH SHERWIN WILLIAMS) WASHABLE EGGSHELL FINISH JOTUN S 1002 - Y50R TO MATCH

EGRET WHITE 7570

SHERWIN WILLIAMS, BENJAMIN

MOORE

P6 HM DOOR/FRAME JOTUN (TO MATCH SHERWIN WILLIAMS) SEMI-GLOSS HIGH PERFORMANCE FINISH JOTUN S 0730 TO MATCH

CYBERSPACE SW7076

HOLLOW METAL DOORS &

FRAMES

SHERWIN WILLIAMS, BENJAMIN

MOORE

RB1 RUBBER BASE- QUARTER ROUND JOHNSONITE ITEM # QTR-32-A PEBBLE 32 12mm x 12mm, USED IN

CONJUNCTION WITH RESILIENT

FLOORING

ROPPE, FLEXCO

ROOM FINISH SCHEDULE

ROO

M NO ROOM NAME WALL FINISH BASE FINISH

FLOOR CEILING

NOTES & REMARKSFIN. FIN.

101 PUMP ROOM P3 N/A C1 EXP./P2

103 CHLR. STOR. P3 N/A C1 P2

104 VFD CTR RM P3 N/A C1 P2

ACT ACOUSTICAL CEILING TILE

C COATING

CT CERAMIC PORCELAIN TILE

EF ENTRANCE FLOORING

EXP EXPOSED

GRT GROUT

GYP GYPSUM BOARD

N/A NOT APPLICABLE

P PAINT

PT PORCELAIN TILE

PTB PORCELAIN TILE BASE

QT QUARRY TILE

QTB QUARRY TILE BASE

RB RUBBER BASE

SDT STATIC DISSIPATIVE TILE

TP TOILET PARTITION

FINISH NOTES:

FINISH LEGEND:

1. SEE TECHNICAL SPECIFICATIONS & INTERIOR FINISH

SCHEDULES FOR INTERIOR FINISH INFORMATION.

2. ALL METAL GRILLES, DIFFUSERS, PANEL BOXES,

REGISTERS, ETC. LOCATED WITHIN OCCUPIED AREAS ARE

TO BE PAINTED TO MATCH THE ADJACENT WALL FINISH AS

NOTED ON THE FINISH SCHEDULES.

3. SEE ARCHITECTURAL DETAIL DRAWINGS FOR INTERIOR

CASEWORK & ADDITIONAL FINISH CONSTRUCTION DETAILS.

4. ALL CONTROL JOINTS TO MATCH THE COLOR OF THE

FLOORING MATERIAL.

5. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS

FOR CEILING HEIGHTS.

6. ALL INTERIOR CONCRETE WALLS ARE FINISHED WITH A

SMOOTH PLASTER FINISH AND PAINTED AS SCHEDULED

7. REFER TO INTERIOR DETAILS FOR TYPICAL WALL

PATTERNS AND CORNER DETAILS.

8. INTERIOR MATERIAL AND COLOR SCHEDULE

ENCOMPASSES ALL MATERIALS USED IN ALL BUILDINGS

THROUGHOUT THE PROJECT. REFER TO ROOM FINISH

SCHEDULE FOR APPLICABLE MATERIALS PER BUILDING.

9. REFER TO COLOR AND MATERIAL SCHEDULE FOR

ACCEPTABLE ALTERNATE MANUFACTURERS. COLORS AND

PATTERNS MUST CLOSELY MATCH BASIS OF DESIGN AND BE

SUBMITTED FOR APPROVAL.

AM

EN

D

M

EN

T #2

-2

2- 1 8

AM

EN

D

M

EN

T #4

-0

4- 1 8

Sheets
G-012 - INDEX OF DRAWINGS
JR-463243I - FIRE PUMP HOUSE - PACKAGE 1 AM#4_n0tamdlh.pdf
Sheets
I-601 - INTERIOR FINISH SCHEDULE

File details come from the government source that posted it.