Amendment 0004 - WVA B125 Reno - Plans.pdf
PDF 434 KB Posted
- Attached to
- WVA Renovate Building 125 Federal contract opportunity
- Solicitation number
- W912DS23B0008
About this file
This document package includes construction plans, load schedules, single line diagrams, and door schedules for the renovation of Building 125 at the West Virginia Army National Guard Mortar Facility. The renovation work includes repairs and replacements to exterior doors and frames, installation of high-speed fabric doors, electrical upgrades, and other modifications. The solicitation was issued by the Department of the Army Corps of Engineers Engineering District New York for solicitation number W912DS23B0008. Offerors should reference all provided documents for requirements and technical details related to the renovation scope of work.
View the file
Other files for this federal contract opportunity
Show all 24
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2"
SCHED.
SEE
2"
S E
E S
C H
E D
H.M.
FRAME
F1
D4 D1
SCHED.
SEE
S E
E S
C H
E D
D2
SCHED.
SEE
S E
E S
C H
E D
6"
6"
S E
E S
C H
E D
SEE SCHED.
HOOD W/COVER
D3
SCHED.
SEE
S E
E S
C H
E D
F R
O M
F F
M A
X
F R
O M
F F
M A
X
TYP
6"
1/4" SAFTY GLASS
2' - 0"
LOUVER
VISION PANEL PER
MANUF. STANDARD
1. HARDWARE FINISHES TO BE BRUSHED STAINLESS UNO.
2. COORDINATE DOOR HARDWARE WITH ELECTRICAL.
3. COORDINATE DOOR HARDWARE WITH THE COR SECURITY SYSTEM.
4. SEE SPECIFICATION SECTION 08 71 00 FOR DOOR HARDWARE SETS
5. HM DOORS AND HM FRAMES TO BE PAINTED TO MATCH EXISTING UNO.
6. STANDARD STOREFRONT DOOR HARDWARE WITH STOREFRONT SYSTEM.
7. PROVIDE DOOR SILENCERS FOR ALL DOORS.
8. PROVIDE DUST PROOF STRIKES FOR FLUSH BOLTS AND VERTICAL RODS.
9. MOTORIZED HI-SPEED FABRIC DOOR W/ MOTION SENSOR ON BOTH SIDES OF THE WALL TO OPEN
AUTOMATICALLY ON APPROACH. THE BOTTOM OF THE DOOR IS REQUIRED TO HAVE A SOFT-EDGE.
THESE SHOULD ALSO BE PROVIDED WITH A HOOD COVER, A VISION PANEL, BREAK-AWAY TABS, AND
MANUAL BACK-UP CHAIN
CLA = CLEAR ANODIZED
F = FIRE RATE TEMPERED GLASS
FAB = HIGH SPEED FABRIC DOOR
HM = HOLLOW METAL
INS = INSULATED GLASS
PF = PRE-FINISHED (BY MANUFACTURER)
PT = PAINT
ST = STAINED
STL = STEEL
W = WIRE GLASS
WD = WOOD
T = TEMPERED GLASS
W = WIRE CLASS
WD = WOOD
1/2"1/2"
BATT
INSULATION
LIGHT GAUGE
FRAMING
HEADER
5/8" GYPSUM BOARD
AS SCHEDULED SEE
PLAN FOR WALL TYPE
HM FRAME
/2
/2
5/8" GYPSUM BOARD
AS SCHEDULED SEE
PLAN FOR WALL TYPE
2"
3 5/8" METAL STUDS
HM FRAME
S E
E S
C H
E D
U L E
SEE PLAN FOR
WALL TYPE
G
A G
A L V
P
L A
T E
E A
C H
S
ID
E
W
IT
H
G
A S
T R
U C
T S
T U
D
T O
P A
N D
B O
T T
O M
RAPID ROLL INSTALL
PER MANUFACTURER
INSTRUCTIONS
16GA GALV.
BEND PLATE
SEE PLAN FOR WALL
TYPE
S E
E S
C H
E D
U L E
3 - 12GA STRUCT STUDS
WITH 12GA PLATE TO
BOTTOM OF ROOF DECK
RAPID ROLL DOOR &
TRACK INSTALL PER
MANUFACTURER
INSTRUCTIONS
16GA GALV.
BENT PLATE
HM FRAME
BEYOND
FINISH FLOOR
/4
DOOR AS SCHEDULED
DOOR
UNDERCUT
CF STUD WALL
BEYOND
SOFT-EDGE
WEATHERSEAL
CLOSURE
V .I .F
E Q
U A
L
V.I.F.
EQUAL
V.I.F.
EQUAL
V.I.F.
EQUAL
V.I.F.
EQUAL
NEW 2"X2" SQUARE OPENING
STEEL WIRE MESH IN 2”X2”
SQUARE STEEL FRAME
BOLTED INTO SURROUNDING
BRICK / CONCRETE W/3/8"X3"
ANCHOR BOLTS TOP &
BOTTOM, WHITE FINISH, TYP.
V .I .F
E Q
U A
L
V .I .F
E Q
U A
L
NEW TINTED SECURTIY FILM TO
BE APPLIED TO INSIDE FACE OF
ALL EXISTING STOREFRONT
PANES, TYP. SEE SPEC FOR
INSTALLATION TOLERANCES.
CONTRACTOR IS TO PREPARE
AND CLEAN THE WINDOW AS
NECESSARY AND NOTIFY
USACE OF ANY WINDOW
DISCREPANCIES PRIOR TO FILM
INSTALLATION. FILM
INSTALLATION IS TO PRODUCE
ZERO AIR BUBBLES OR GAPS.
F O
R R
O U
G H
P E
N
IN
G
S E
E W
A L L S
E C
T
IO
N
COL
EXISTING MASONARY
TO REMAIN
EXISTING STOREFRONT
SYSTEM TO REMAIN
NEW 2"X2" SQUARE OPENING STEEL WIRE
MESH IN 2”X2” SQUARE STEEL FRAME
BOLTED INTO SURROUNDING BRICK /
CONCRETE W/3/8"X3" ANCHOR BOLTS
TOP & BOTTOM, WHITE FINISH, TYP.
NEW TINTED SECURTIY FILM TO BE APPLIED TO INSIDE
FACE OF ALL EXISTING STOREFRONT PANES, TYP. SEE
SPEC FOR INSTALLATION TOLERANCES. CONTRACTOR IS
TO PREPARE AND CLEAN THE WINDOW AS NECESSARY
AND NOTIFY USACE OF ANY WINDOW DISCREPANCIES
PRIOR TO FILM INSTALLATION. FILM INSTALLATION IS TO
PRODUCE ZERO AIR BUBBLES OR GAPS.
2" MIN.2"
VIF
1"
ALIGN
V .I
.F
5'-6" @ EXISTING SINGLE DOOR, V.I.F.
+/- 9' - 9 1/2" ALIGN W/CL OF MULLIONS @ DOOR 001, V.I.F.
SLOPE 1/4" PER FOOT MIN.
EXISTING STOREFRONT
METAL CANOPY, SEE
STRUCT. DETAILS
METAL GUTTER
METAL FLASHING
W/SEALANT @ GLAZING
SHIM AS REQ'D
2' - 6" 2' - 6" 4" 1
M
IN
BOLLARD, BOTH SIDES - SEE CIVIL
2' - 0" 2' - 0"2' - 0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C
N
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
LEGAL ENTITY:
ARCADIS U.S., INC. 80-A602
D O
O R
S C
H E
D U
L E
U S
A C
E
W V
A M
O R
T A
R F
A C
IL
IT
Y
P H
A S
E
D e s ig n e r
A u th o r
C h e c k e r
Is s u e D a te
AMENDMENT 0004
DOOR SCHEDULE
DOOR NO.
DOOR
FIRE
RATING
FRAME
HARDWARE SECURITY COMMENTS:
SIZE
MATERIAL FINISH ELEVATION MATERIAL FINISH ELEVATION
DETAIL
WIDTH HEIGHT THICKNESS HEAD JAMB SILL
001 6' - 1 21/32" 7' - 0" ALUM/GLASS MATCH
EXIST
ALUM MATCH
EXIST
SET 4 EXIST CAC REPAIR AND/OR REPLACE EXTERIOR DOUBLE DOORS, FRAMES, & CENTER
MULLION TO MATCH EXISTING. PREP FOR NEW HARDWARE, ALIGN, & REINSTALL.
002 6' - 0" 7' - 0" ALUM/GLASS MATCH
EXIST
ALUM MATCH
EXIST
SET 4 EXIST CAC REPAIR AND/OR REPLACE EXTERIOR DOUBLE DOORS, FRAMES, & CENTER
MULLION TO MATCH EXISTING. PREP FOR NEW HARDWARE, ALIGN, & REINSTALL.
101 3' - 0" 7' - 0" 1 3/4" HM PT D3 HM PT F1 H1 J1 S1 SET 4
109A 6' - 0" 7' - 0" 1 3/4" HM PT D2 (PR) 60 MIN HM PT F1 H1 J1 S1 SET 2 CAC
109B 6' - 0" 7' - 0" 1 3/4" HM PT D2 (PR) 60 MIN HM PT F1 H1 J1 S1 SET 2 CAC
109C 6' - 0" 7' - 0" 1 3/4" HM PT D2 (PR) 60 MIN HM PT F1 H1 J1 S1 SET 2 CAC
112 3' - 0" 7' - 0" 1 3/4" HM PT D3 HM PT F1 H1 J1 S1 SET 1 CAC
143A 3' - 0" 7' - 0" 1 3/4" HM PT D1 HM PT F1 H1 J1 S1 SET 3 MECH KEY
143B 3' - 0" 7' - 0" 1 3/4" HM PT D1 HM PT F1 H1 J1 S1 SET 3 MECH KEY
143C 3' - 0" 7' - 0" 1 3/4" HM PT D1 HM PT F1 H1 J1 S1 SET 3 MECH KEY
144A 3' - 0" 7' - 0" 1 3/4" HM PT D1 HM PT F1 H1 J1 S1 SET 3 MECH KEY
144B 3' - 0" 7' - 0" 1 3/4" HM PT D1 HM PT F1 H1 J1 S1 SET 3 MECH KEY
144C 3' - 0" 7' - 0" 1 3/4" HM PT D1 HM PT F1 H1 J1 S1 SET 3 MECH KEY
191 6' - 0" 7' - 0" 1 3/4" HM PT D3 (PR) HM PT F1 H1 J1 S1 SET 2 CAC
197A 3' - 0" 7' - 0" 1 3/4" HM PT D2 HM PT F1 H1 J1 S1 SET 1 CAC
197B 14' - 0" 14' - 0" 1" FABRIC PF D4 STL PF N/A H2 J2 S2 PER MFR PADLOCK SEE DOOR SCHEDULE NOTE 9
EXIST 3' - 0" 7' - 0" 1 3/4" EXISTING TO REMAIN
SCALE: 1/4" = 1'-0"
DOOR AND FRAME ELEVATIONS
DOOR SCHEDULE NOTES
DOOR SCHEDULE ABBREVIATIONS
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
D E
S
IG
N
/2
/2
D E
S
IG
N
/0
/2
D E
S
IG
N
/0
/2
B
A C
K C
H E
C K
S E
T
/2
/2
A
M E
N D
M E
N T
/1
/2
A
M E
N D
M E
N T
/2
/2
SCALE: 1 1/2" = 1'-0"
HEAD DETAIL H1
SCALE: 1 1/2" = 1'-0"
JAMB DETAIL J1
SCALE: 1 1/2" = 1'-0"
HEAD DETAIL H2
SCALE: 1 1/2" = 1'-0"
JAMB DETAIL J2
SCALE: 1 1/2" = 1'-0"
SILL DETAIL S1
SCALE: 1 1/2" = 1'-0"
SILL DETAIL S2
SCALE: 1/4" = 1'-0"
1 TYP. WINDOW SECURITY FENCE
SCALE: 1 1/2" = 1'-0"80-A303
2 DETAIL @ WINDOW SILL (HEAD/JAMB SIM.)
0' 4' 8'2'
0' 1' 2'
SCALE: 1/2" = 1'-0"
10 BID OPTION CANOPY DETAILS
0' 2' 4'1'0' 4' 8'2'
400 AF
400 AT
CN1-3
CN1-3
E0002-11
SPACE SPACE
600 AF
600 AT
E0002-14
800 AF
800 AT
E0003-01
600 AF
600 AT
SPACE SPACE SPACE
S.E.S-1B1A
1600A MCB, 480Y/277V, 3PH, 4W, 22KAIC
400 AF
400 AT
CN1-2
CN1-2
COMMON
ELECTRICAL
ROOM
E0002-02
CH-1
CH-1 CHILLER
125 AF
125 AT
E0002-03
CH-2
CH-2 CHILLER
125 AF
125 AT
E0002-04
225 AF
225 AT
CN1-4
CN1-4
E0002-05
150 AF
150 AT
EHC-1
EHC-1
E0002-07
CN-1 (COMMON ELECT RM)
800A, 480Y/277V, 3PH, 4W, 22KAIC
S.E.S-1B1A-MTS
S.E.S-1B1A-MTS
E0002
FROM EXISTING
15KV FUSED
SWITCH
FROM EXISTING
15KV FUSED
SWITCH
225 AF
225 AT
225 AF
225 AT
400 AF
400 AT
450 AF
450 AT
VE1T-1
E0003-06
VN1-1 (ELECTRICAL ROOM)
800A, 480Y/277V, 3PH, 4W, 22KAIC
AHU-1
AHU-1
250 AF
250 AT
E0002-15
AHU-2
AHU-2
250 AF
250 AT
E0002-16
CN1-5 (AHU)
600A, 480Y/277V, 3PH, 4W
800 AF
800 AT
E0002-01
SPACE
100 AF
100 AT
EHC-2
EHC-2
E0002-08
225 AF
225 AT
CNT1-1
CNT1-1
E0002-09
CNT1-2
CNT1-2
E0002-12
CN2-2
CN2-2
E0002-13
CN1-4A
CN1-4A
E0002-06
CN2-1
CN2-1
E0002-10
E0003-08
VE2-1
VE2-1
E0003-07
VE2-2
VE2-2
E0003-09
NOTES:
1. SINGLE LINE DIAGRAM BASED FROM EXISTING FACILITY AS-BUILTS AND HAS NOT
BEEN FIELD VERIFIED. CONTRACTOR SHALL VERIFY EXISTING EQUIPMENT IN FIELD.
2. REFER TO SHEET 160-E400 FOR CORRESPONDING CONDUIT TABLE FOR CONDUIT
TAGS SHOWN ON THIS SHEET.
3. THIS SINGLE LINE DIAGRAM IS SHOWN FOR REFERENCE ONLY. NO NEW WORK IS
BEING PROPOSED.
SPARE
SPARE SPARE SPARE
PROVIDE NEW CIRCUIT BREAKER MATCHING EXISTING CIRCUIT BREAKERS IN
EXISTING SPACE, TYPICAL FOR ALL BREAKERS TO BE INSTALLED IN SWITCHBOARD
S.E.S-1B1A.
KEY NOTES:
EXISTING CIRCUIT BREAKER TO REMAIN
800 AF
800 AT
SPARE
EXISTING 45KVA. 480V-208Y/120V TRANSFORMER FROM MEZZANINE CATWALK
EXISTING 120/208Y PANELBOARD FROM MAZZANING CATWALK
CN2-2
CN2-2
E0002-13
VNT1-1
P0002-1
VN2-1
VN2-1
VNT1-1
P0002
D
C
BBBBB A
A
B
C
D
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
LEGAL ENTITY:
ARCADIS U.S., INC.
A
D D
E E
N D
M
D E
S
IG
D E
S
D E
S
IG
N
D E
S
IG
N
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
/2
/2
/0
/2
/0
/2
/2
/2
/2
/2
ADDENDUM 4
160-E201
B
P R
O P
O S
E D
S
IN
G
L E
L
IN
E
W E
S T
E L E
C T
R
IC
A L R
O O
M
O
F
U S
A C
E
W V
A M
O R
T A
R F
A C
IL
IT
Y D e s ig n e r
A u th o r
C h e c k e r
Is s u e D a te
D E
S
IG
N /0
/2
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
LEGAL ENTITY:
D D
E E
N D
D E
S
D E
S
D E
S
IG
N
D E
S
IG
N
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
/1
/2
/0
/2
/0
/2
/2
/2
/2
/2
ADDENDUM 4
A
D D
E E
N D
/2
/2
160-E207
B
L O
A D
S C
H E
D U
L E
S
U S
A C
E
W V
A M
O R
T A
R F
A C
IL
IT
Y D e s ig n e r
A u th o r
C h e c k e r
Is s u e D a te
REMAINING SPACE-26%
REMAINING AMPACITY-42%
Notes:
Total Est. Demand: 307 A
Total Conn.: 307 A
Total Est. Demand: 255.33 kVA
Lighting 10 kVA 100.00% 10 kVA Total Conn. Load: 255.33 kVA
Spare 245.34 kVA 100.00% 245.34 kVA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 306 A 325 A 294 A
Total Load: 84.26 kVA 89.66 kVA 81.41 kVA
41 3.9 kVA 25 kVA 42
39 3.9 kVA 25 kVA 40
EF-2 20 A 3
3.9 kVA 25 kVA
3 70 A VNT1-1 (45KVA XFMR)
35 0 kVA 3.9 kVA 36
33 0 kVA 3.9 kVA 34
SPARE 30 A 3
0 kVA 3.9 kVA
3 20 A EF-4
29 MANUFACTURING AREA LIGHTING 20 A 1 1.43 kVA 0 kVA 30
27 MANUFACTURING AREA LIGHTING 20 A 1 4.28 kVA 0 kVA 28
25 MANUFACTURING AREA LIGHTING 20 A 1 4.28 kVA 0 kVA
3 30 A SPARE
23 0 kVA 0 kVA 1 60 A SPARE 24
21 0 kVA 10 kVA 22
SPARE 50 A 3
0 kVA 10 kVA 20
17 3.9 kVA 10 kVA
3 50 A FPVAV-151
15 3.9 kVA 5.4 kVA 1 20 A ELECTRICAL RM LIGHTS 16
EF-1 20 A 3
3.9 kVA 0 kVA 1 60 A SPARE 14
11 3.05 kVA 3.9 kVA 12
9 3.05 kVA 3.9 kVA 10
OVERHEAD DOOR 20 A 3
3.05 kVA 3.9 kVA
3 20 A EF-3
5 1.33 kVA 25 kVA 6
3 1.33 kVA 25 kVA 4
E-MON D-MON METERS 20 A 3
1.33 kVA 25 kVA
3 125 A CNT1-2 (75KVA XFMR)
CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT
Notes:
Enclosure: 1 MCB Rating: 400 A
Mounting: Surface Wires: 4 Mains Rating: 400 A
Supply From: S. E. S. 1B1A Phases: 3 Mains Type: Main Circuit Breaker
Location: ELEC. 149 Volts: 480/277 Wye A.I.C. Rating: 35k
Branch Panel: CN1-3
Notes:
Total Est. Demand: 2190 A
Total Conn.: 2190 A
Total Est. Demand: 1820.9 kVA
Total Conn. Load: 1820.9 kVA
PRODUCTION TOOL NAME 1820.9 kVA 100.00% 1820.9 kVA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Total Amps: 2190 A
Total Conn. Load: 1820.9 kVA
10 EXISTING PP-125-3-1 3 1200 A 1000 A 68.0 kVA 68.0 kVA 68.0 kVA
9 EXISTING PP-125-3-2 3 1200 A 1000 A 68.0 kVA 68.0 kVA 68.0 kVA
8 EXISTING PP-125-4-1 3 1200 A 1000 A 24.3 kVA 24.3 kVA 24.3 kVA
7 EXISTING PP-125-4-2 3 1200 A 1000 A 26.0 kVA 26.0 kVA 26.0 kVA
6 EXISTING PP-125-5-1 3 1200 A 1000 A 45.0 kVA 45.0 kVA 45.0 kVA
5 EXISTING PP-125-5-2 3 1200 A 1000 A 0.0 kVA 0.0 kVA 0.0 kVA
4 PP-125-2-1 3 1200 A 1000 A 96.0 kVA 96.0 kVA 96.0 kVA
3 PP-125-2-2 3 1200 A 1000 A 138.0 kVA 138.0 kVA 138.0 kVA
2 PP-125-1-1 3 1200 A 1000 A 83.3 kVA 83.3 kVA 83.3 kVA
1 PP-125-1-2 3 1200 A 1000 A 58.3 kVA 58.3 kVA 58.3 kVA
SECTION Circuit Description # of Poles Frame Size Trip Rating
A B C
Remarks
Enclosure: 1 MCB Rating: 5000 A
Mounting: Floor Wires: 4 Mains Rating: 5000 A
Supply From: Phases: 3 Mains Type:
Location: ELEC. 149 Volts: 480/277 Wye A.I.C. Rating:
Switchboard: 1B1A-SWGR-1-W
NOTES:
1. EXISTING PANEL CIRCUIT DESCRIPTIONS BASED ON FIELD PANEL
SCHEDULES WHICH DID NOT INCLUDE LOAD VALUES. LOAD
VALUES BASED ON 2008 AS-BUILTS. CONTRACTOR TO FIELD
VERIFY.
SOUTH-2 XFMR
REMAINING SPACE-57%
REMAINING AMPACITY-30%
Notes:
Total Est. Demand: 68 A
Total Conn.: 68 A
Total Est. Demand: 24.43 kVA
Total Conn. Load: 24.43 kVA
Spare 24.43 kVA 100.00% 24.43 kVA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 70 A 68 A 66 A
Total Load: 8.41 kVA 8.1 kVA 7.92 kVA
41 SPACE -- 1 -- -- 1 -- SPACE 42
39 LIGHTING & RECEPT. IDF1A,B,C 143A,B,C 20 A 1 0.27 kVA -- 1 -- SPACE 40
37 MOMS ROOM 133 & ENTRANCE RECEPT. 20 A 1 1.8 kVA -- 1 -- SPACE 38
35 SECURITY OFFICE RECEPT. 20 A 1 1.44 kVA 0 kVA 1 20 A SPARE 36
33 ADMIN 101 RECEPT. 20 A 1 1.8 kVA 0 kVA 1 20 A SPARE 34
31 LIGHTING RECEIVING 104 20 A 1 1.16 kVA 0 kVA 1 20 A SPARE 32
29 RECIEVING 104 RECEPT. 20 A 1 1.08 kVA 0 kVA 1 20 A SPARE 30
27 LIGHTING & RECEPT. IDF2A,B,C 144A,B,C 20 A 1 0.27 kVA 0 kVA 1 20 A SPARE 28
25 SPARE 20 A 1 0 kVA 0 kVA 1 20 A SPARE 26
23 SPARE 20 A 1 0 kVA 0 kVA 1 20 A SPARE 24
21 ENTRANCE, MOMS, & ADMIN ROOM LIGHTS 20 A 1 0.36 kVA 0 kVA 1 20 A SPARE 22
19 SECURITY OFFICE LIGHTS 20 A 1 0.05 kVA 0 kVA 1 20 A SPARE 20
17 COLUMN RECEPTACLES 20 A 1 1.8 kVA 0 kVA 1 20 A SPARE 18
15 COLUMN RECEPTACLES 20 A 1 1.8 kVA 0 kVA 1 20 A SPARE 16
13 COLUMN RECEPTACLES 20 A 1 1.8 kVA 0 kVA 1 20 A SPARE 14
11 COLUMN RECEPTACLES 20 A 1 1.8 kVA 0 kVA 1 20 A SPARE 12
9 COLUMN RECEPTACLES 20 A 1 1.8 kVA 0 kVA 1 20 A SPARE 10
7 COLUMN RECEPTACLES 20 A 1 1.8 kVA 0 kVA 1 20 A SPARE 8
5 COLUMN RECEPTACLES 20 A 1 1.8 kVA 0 kVA 1 20 A SPARE 6
3 COLUMN RECEPTACLES 20 A 1 1.8 kVA 0 kVA 1 20 A SPARE 4
1 COLUMN RECEPTACLES 20 A 1 1.8 kVA 0 kVA 1 20 A SPARE 2
CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT
Notes:
Enclosure: 1 MCB Rating: 225 A
Mounting: Surface Wires: 4 Mains Rating: 225 A
Supply From: Phases: 3 Mains Type: Main Circuit Breaker
Location: Volts: 120/208 Wye A.I.C. Rating: 10kA
Branch Panel: VN2-1
SOUTH-2 XFMR
100A
100A
MANUFACTURING SHOP AREA
CN1-3
4 kVA
2 kVA
1.9 kVA
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
LEGAL ENTITY:
D D
E E
N D
D E
S
D E
S
D E
S
IG
N
D E
S
IG
N
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
/2
/2
/0
/2
/0
/2
/2
/2
/2
/2
ADDENDUM 4
160-E400
B
C O
N D
U
IT
S C
H E
D U
L E
W
E S
T E
L E
C T
R
IC
A L R
O O
M A
N D
B U
S W
A Y
S
U S
A C
E
W V
A M
O R
T A
R F
A C
IL
IT
Y D e s ig n e r
A u th o r
C h e c k e r
Is s u e D a te
WEST ELEC ROOM 1 OF 2
CONDUIT
IDENTIFIER SOURCE DESTINATION
CONDUIT
SIZE
CONDUCTOR
DESCRIPTION
E0001 EXISTING
15KV FUSED
SWITCH
15KV LOAD
CURRENT
INTERRUPTER
SWITCH
EXISTING EXISTING
E0001 EXISTING
15KV FUSED
SWITCH
15KV LOAD
CURRENT
INTERRUPTER
SWITCH
EXISTING EXISTING
E0001-03 1B1A-SWGR-
1-W SEC-3
PP-125-3-1 EXISTING EXISTING
E0001-05 1B1A-SWGR-
1-W SEC-3
PP-125-3-2 EXISTING EXISTING
E0001-08 1B1A-SWGR-
1-W SEC-2-1
PP-125-4-1 EXISTING EXISTING
E0001-10 1B1A-SWGR-
1-W SEC-2
PP-125-4-2 EXISTING EXISTING
E0001-13 1B1A-SWGR-
1-W SEC-1
PP-125-5-1 EXISTING EXISTING
E0001-15 1B1A-SWGR-
1-W SEC-1
PP-125-5-2 EXISTING EXISTING
E0001-15 1B1A-SWGR-
1-W SEC-1
PP-125-5-2 EXISTING EXISTING
E0001-15 1B1A-SWGR-
1-W SEC-1
PP-125-5-2 EXISTING EXISTING
P0001 1B1A-SWGR-
1-W SEC-3
PP-125-1-1 (4) 3-1/2" C
OR TRAY
(4) 350 KCMIL - (1) 3/0
GND IN EACH CONDUIT
(4
CONDUCTORS/PHASE)
P0002 PP-125-1-1 BUSWAY BAY
1-EAST
BUSWAY BUSWAY
P0003 1B1A-SWGR-
1-W SEC-3
PP-125-1-2 (4) 3-1/2" C
OR TRAY
(4) 350 KCMIL - (1) 3/0
GND IN EACH CONDUIT
(4
CONDUCTORS/PHASE)
P0005 1B1A-SWGR-
1-W SEC-3
PP-125-2-1 (4) 3-1/2" C
OR TRAY
(4) 350 KCMIL - (1) 3/0
GND IN EACH CONDUIT
(4
CONDUCTORS/PHASE)
P0007 1B1A-SWGR-
1-W SEC-3
PP-125-2-2 (4) 3-1/2" C
OR TRAY
(4) 350 KCMIL - (1) 3/0
GND IN EACH CONDUIT
(4
CONDUCTORS/PHASE)
WEST ELEC ROOM 2 OF 2
CONDUIT
IDENTIFIER SOURCE DESTINATION
CONDUIT
SIZE
CONDUCTOR
DESCRIPTION
E0002 EXISTING
15KV FUSED
SWITCH
S.E.S-1B1A-MT
S
EXISTING EXISTING
E0002-01 S.E.S-1B1A CN1-1 EXISTING EXISTING
E0002-01 S.E.S-1B1A CN1-1 EXISTING EXISTING
E0002-02 CN1-1 CN1-2 EXISTING EXISTING
E0002-03 CN1-1 CH-1 EXISTING EXISTING
E0002-04 CN1-1 CH-2 EXISTING EXISTING
E0002-05 CN1-1 CN1-4 EXISTING EXISTING
E0002-06 CN1-4 CN1-4A EXISTING EXISTING
E0002-07 CN1-1 EHC-1 EXISTING EXISTING
E0002-08 CN1-1 EHC-2 EXISTING EXISTING
E0002-09 CN1-1 CNT1-1 EXISTING EXISTING
E0002-10 CNT1-1 CN2-1 EXISTING EXISTING
E0002-11 S.E.S-1B1A CN1-3 EXISTING EXISTING
E0002-12 CN1-3 CNT1-2 EXISTING EXISTING
E0002-13 CNT1-2 CN2-2 EXISTING EXISTING
E0002-13 CNT1-2 CN2-2 EXISTING EXISTING
E0002-14 S.E.S-1B1A CN1-5 EXISTING EXISTING
E0002-15 CN1-5 AHU-1 EXISTING EXISTING
E0002-16 CN1-5 AHU-2 EXISTING EXISTING
E0003 EXISTING
15KV FUSED
SWITCH
S.E.S-1B1A EXISTING EXISTING
E0003-01 S.E.S-1B1A VN1-1 EXISTING EXISTING
E0003-02 VN1-1 VN1-2 EXISTING EXISTING
E0003-04 SPARE SPARE EXISTING EXISTING
E0003-05 VN1-1 VN1-4 EXISTING EXISTING
E0003-06 VN1-1 VE1T-1 EXISTING EXISTING
E0003-07 VE1T-1 VE2-1 EXISTING EXISTING
E0003-08 VE1T-1 UPS ECB EXISTING EXISTING
E0003-09 UPS ECB VE2-2 EXISTING EXISTING
E0003-11 S.E.S-1B1A VN1-1A EXISTING EXISTING
BW-B-1W & BW-B-1E
CONDUIT
IDENTIFIER SOURCE DESTINATION
CONDUIT
SIZE
CONDUCTOR
DESCRIPTION
P0001 1B1A-SWGR-
1-W SEC-3
PP-125-1-1 (4) 3-1/2" C
OR TRAY
(4) 350 KCMIL - (1) 3/0
GND IN EACH CONDUIT
(4
CONDUCTORS/PHASE)
P0002-01 BUSWAY BAY
1-EAST
WV12801 2" C (3) 2/0 - 1 # 6 GND
P0002-02 BUSWAY BAY
1-EAST
WV12915 1 1/2" C (3) # 1 - 1 # 6 GND
P0002-03 BUSWAY BAY
1-EAST
WV12849 1 1/2" C (3) # 1 - 1 # 6 GND
P0003 1B1A-SWGR-
1-W SEC-3
PP-125-1-2 (4) 3-1/2" C
OR TRAY
(4) 350 KCMIL - (1) 3/0
GND IN EACH CONDUIT
(4
CONDUCTORS/PHASE)
P0004-01 BUSWAY BAY
1-WEST
WV12572 2" C (3) 2/0 - 1 # 6 GND
P0004-02 BUSWAY BAY
1-WEST
WV12914 1 1/2" C (3) # 1 - 1 # 6 GND
P0004-03 BUSWAY BAY
1-WEST
WV12850 1 1/2" C (3) # 1 - 1 # 6 GND
BW-B-2W & BW-B-2E
CONDUIT
IDENTIFIER SOURCE DESTINATION
CONDUIT
SIZE
CONDUCTOR
DESCRIPTION
P0005 1B1A-SWGR-
1-W SEC-3
PP-125-2-1 (4) 3-1/2" C
OR TRAY
(4) 350 KCMIL - (1) 3/0
GND IN EACH CONDUIT
(4
CONDUCTORS/PHASE)
P0006-01 BUSWAY BAY
2-EAST
RAPID BORE 2 1/2" C (3) 350 KCMIL - 1 # 4
GND
P0006-02 BUSWAY BAY
2-EAST
HONE 1 1/2" C (3) # 3 - 1 # 8 GND
P0006-03 BUSWAY BAY
2-EAST
WV12373 1 1/2" C (3) # 3 - 1 # 8 GND
P0007 1B1A-SWGR-
1-W SEC-3
PP-125-2-2 (4) 3-1/2" C
OR TRAY
(4) 350 KCMIL - (1) 3/0
GND IN EACH CONDUIT
(4
CONDUCTORS/PHASE)
P0008-01 BUSWAY BAY
2-WEST
RAPID BORE 2 1/2" C (3) 350 KCMIL - 1 # 4
GND
P0008-02 BUSWAY BAY
2-WEST
WV12785 2 1/2" C (3) 350 KCMIL - 1 # 4
GND
P0008-03 BUSWAY BAY
2-WEST
WV12372 1 1/2" C (3) # 3 - 1 # 8 GND
BW-B-3W & BW-B-3E
CONDUIT
IDENTIFIER SOURCE DESTINATION
CONDUIT
SIZE
CONDUCTOR
DESCRIPTION
E0001-03 1B1A-SWGR-
1-W SEC-3
PP-125-3-1 EXISTING EXISTING
E0001-05 1B1A-SWGR-
1-W SEC-3
PP-125-3-2 EXISTING EXISTING
P0029-01 BUSWAY BAY
3-EAST
WV12826 2 1/2" C (3) 250 KCMIL - 1 # 4
GND
P0029-02 BUSWAY BAY
3-EAST
WV12819 1" C (3) # 12 - 1 # 12 GND
P0029-03 BUSWAY BAY
3-EAST
WV12769 1" C (3) # 4 - 1 # 8 GND
P0030-01 BUSWAY BAY
3-WEST
WV12825 2 1/2" C (3) 250 KCMIL - 1 # 4
GND
P0030-02 BUSWAY BAY
3-WEST
WV12818 1" C (3) # 12 - 1 # 12 GND
P0030-03 BUSWAY BAY
3-WEST
WV12770 1" C (3) # 4 - 1 # 8 GND
BW-B-4W & BW-B-4E
CONDUIT
IDENTIFIER SOURCE DESTINATION
CONDUIT
SIZE
CONDUCTOR
DESCRIPTION
E0001-10 1B1A-SWGR-
1-W SEC-2
PP-125-4-2 EXISTING EXISTING
E0001-10 1B1A-SWGR-
1-W SEC-2
PP-125-4-2 EXISTING EXISTING
P0027-01 BUSWAY BAY
4-EAST
WV06343 1" C (3) # 8 - 1 # 8 GND
P0027-02 BUSWAY BAY
4-EAST
WV11875 1" C (3) # 4 - 1 # 8 GND
P0028-01 BUSWAY BAY
4-WEST
WV10685 1" C (3) # 8 - 1 # 8 GND
P0028-02 BUSWAY BAY
4-WEST
WV08841 1" C (3) # 4 - 1 # 8 GND
BW-B-5W & BW-B-5E
CONDUIT
IDENTIFIER SOURCE DESTINATION
CONDUIT
SIZE
CONDUCTOR
DESCRIPTION
E0001-13 1B1A-SWGR-
1-W SEC-1
PP-125-5-1 EXISTING EXISTING
E0001-15 1B1A-SWGR-
1-W SEC-1
PP-125-5-2 EXISTING EXISTING
P0025-01 BUSWAY BAY
5-EAST
WV12746 1 1/2" C (3) # 1 - 1 # 6 GND
P0025-02 BUSWAY BAY
5-EAST
WV12761 1 1/2" C (3) # 3 - 1 # 8 GND
P0026-01 BUSWAY BAY
5-WEST
WV12766 1 1/2" C (3) # 1 - 1 # 6 GND
P0026-02 BUSWAY BAY
5-WEST
WV10841 1 1/2" C (3) # 1 - 1 # 6 GND
CN1-3 VNT1-1 1" C (3) #4-(1) #8 GND
4/0
P0002
VNT1-1 VNT2-1 1-1/2" C (3) 1/0-(1) #6 GND P0002-1 4
| AUS_ WVABLDG125 _R21_ELEC - Sheet - 160-E201 - B125 - PROPOSED - SINGLE LINE - WEST ELECTRICAL ROOM (2 OF 2) |
| AUS_ WVABLDG125 _R21_ELEC - Sheet - 160-E207 - B125 - LOAD SCHEDULES |
| AUS_ WVABLDG125 _R21_ELEC - Sheet - 160-E400 - B125 - CONDUIT SCHEDULE - WEST ELECTRICAL ROOM AND BUSWAYS |
| WVABLDG125_Amendment 0004_80-A602.pdf |
| Sheets |
| 80-A602 - DOOR SCHEDULE |
File details come from the government source that posted it. Updated .