Request for Proposal, Design Build Renovate Dormitory Building 97 Thule Air Base, Greenland 24 July 2014
SLIDING DOORS
Sliding Doors Europe Page 1 of 3 /THJ. D. 2014.06.10
Sliding Doors Europe
Large Scandinavian door manufacturer:
http://www.jeld-wen.dk/inspiration/indvendige-doere/artikler/skydedoere/ (On website Slide presentation pictures)
10 examples on sliding doors surfacelooks Danish “skydedør” http://www.jeld-wen.dk/produkter/indvendige-doere/doere/#/1/100/~/~/~/~/~/~ http://www.jeld-wen.dk/inspiration/indvendige-doere/artikler/skydedoere/
Sliding Doors Europe Page 2 of 3 /THJ. D. 2014.06.10
Wall-Build in kit.
Sliding door installation videos for standard European wall thikness of 96 mm and
122 mm http://www.jeld-wen.dk/gode-raad/monteringsvejledning/montagevideo-indbygget-skydedoere/
Sliding Doors Europe Page 3 of 3 /THJ. D. 2014.06.10
Hang on wall sliding doors (European interioer styles website) (where wall space available:
http://freshome.com/2011/06/03/ingenious-door-sliding-system-for-saving-valuable-space-in-your-home/
WINDOWS
TAB Standard window Page 1 of 3 /THJ. D. 2014.06.10
Thule Standard Window
Energy saving Windows - Size (wXh) 720mm x 1050mm - Turn/Kip style- HI, 3-layer
Termo energy glass, Color white Color Code RAL 9016, with easy “press valve” for fresh air.
Primo Type 311. Price class: USD 300 Websites: http://www.primo.dk/ http://www.primovinduer.dk/ Telephone: +45 70 11 12 33.
Top open position http://www.primo.dk/ http://www.primovinduer.dk/
TAB Standard window Page 2 of 3 /THJ. D. 2014.06.10
Same window side open position
TAB Standard window Page 3 of 3 /THJ. D. 2014.06.10
Window build in Air-vent (closed position)
Window build in Air-vent (haf open position)
TEMPORARY HEAT EXCHANGER CONTAINER
#97 Temporary Containerbased Heat Exchanger Page 1 of 4 /THJ. D. 2014.06.10
#97 Temporary Prefab heat exchanger Container
Generally, Thule is steadily is converting from steam to a more energy effective hot water production & distribution system, so this should be implemented for Building #97 as well.
Locally at facility #97 this is cheapest/best done by installing a temporary 20’ container based steam to hot water exchanger unit heat exchanger. Cheapest a standard available insulated container is used. (e.g. an earlier intended refrigerator container. Typically this would be cheaper than including on onsite building of the steam to hot water exchanger in the facility. In long term when hot water becomes available in the heat distribution it is relatively simple to bypass the container, use it elsewhere on base or ship it out of Thule Airbase
Example of container based exchanger unit. Note The out/return manifold shown here has 4 outlets.
#97 Temporary Containerbased Heat Exchanger Page 2 of 4 /THJ. D. 2014.06.10
Suitable location could be:
#97 Temporary Containerbased Heat Exchanger Page 3 of 4 /THJ. D. 2014.06.10
(Typically to double nominal heat exchange capacity is approximately. 30% price increase).So increasing capacity from 0,3MW (appr. to 0,6MW) and doubling outlets on manifold would enable USAF to use the same temporary container in its proposed position for the future programmed renovation of #99 (WWCX10-3007).
Site Plan with temporary container location and heat supply for facility #97 (Red solid) and potential future renovation #99 (Red Dashed).
#97 Temporary Containerbased Heat Exchanger Page 4 of 4 /THJ. D. 2014.06.10
Example of temporary containbaset Nominal capacity of 550 kW heat exchanger with redundant pump setup
LIGHT FIXTURES
Catalog #
Project
Comments
Prepared by
Type
Date
SPECIFICATION FEATURES
09/27/2012 7:55:00 PMConsult your representative for additional options and finishes.
Specifications and Dimensions subject to change without notice. ADE090286
DESCRIPTION
Corelite's latest addition to its line of shallow recessed fixtures, the Class R3, is the ultimate complement to the R1 and R2, offering the ideal combination of performance and aesthetics. The fully luminous housing of the R3 creates a high sense of style and superior brightness management, all while providing low watts per square foot to satisfy the most stringent energy requirements. To further realize the Class R series' design potential, the Class R3 is available with a complete palette of lamp options - including T8 and compact fluorescent - and maintains the series' dedication to shallow plenum applications with a minimal 3-3/4" deep housing.
A ... Construction Low profile housing constructed of die-formed 20 gauge cold rolled steel with integral 20 gauge gear tray.
B ... Reflectors Micro prismatic acrylic lens composed of frosted and clear blend.
C ... Shielding Extruded acrylic center optic with frosted acrylic side lenses. Perf pattern is silkscreened onto the surface of the inlay. Lens is secured to housing via injection molded inserts for easy lamp access.
D ... Electrical T8 fixtures use UL listed Class P, 265ma T8 instant start universal voltage electronic ballasts. Power factor of 95% with less than 10% THD. Fixtures and electrical components certified to UL and CUL standards.
E ... Finish Fixture housings are high reflectance white using electrostatically applied polyester powder coat paint.
Mounting Standard flange design works with most lay-in ceiling types. Integral pryout tabs secure luminaire to ceiling grid from above. Fixture offers tie-in locations for tie-wire on all corners, consult local code for appropriate tie-wire recommendations. Cannot mount more than four (4) fixtures continuously in one direction, or eight (8) fixtures total.
NOTE: Concealed Ceiling Class R may be installed into inaccessible ceilings (sheet rock, wood panel, etc.). This is achieved with the Metalux DFW series drywall frame-in kit, ordered separately from Metalux. Specify "CC" for the Corelite Ceiling Type.
Specify the following part numbers separately, from Metalux:
For 2x2, order Metalux part #
DF-22W-U
CLASS R3
Rectangular Perf
Inlay
Round Perf Inlay
3T8
2'x2' Recessed
3-3/4" Depth
ORDERING INFORMATION
Sample Number: R3-WG-3T8-1C-UNV-22-T1
Wiring 1
B Battery Pack=
C Standard Circuit=
D Dimming / Step Dimming=
E Emergency=
T Nightlight=
Y Daylight=
Options 1
AR Air Return=
CP Chicago Plenum=
SD Step Dimming=
W6 6' Whip Flex=
W12 12' Whip Flex=
Ceiling Type
T1 1" Grid, Slot-Grid, 9/16" Tegular
T9 9/16" Grid=
CC Concealed Ceiling=
SU Surface Mount=
Voltage 1
120 120V=
277 277V=
347 347V=
UNV Universal (120V-277V)
Lamp Type
T8 T8 Normal Output=
Shielding
D Round Perf Inlay=
G Rectangular Perf Inlay=
Series
R3 Class R3=
Number of Circuits
1 1 Circuit=
2 2 Circuits=
Reflector
W White= Number of Lamps
3 3 Lamps=
Size
22 2' x 2'=
1 Not all options available. Please consult your Cooper Lighting Representative for availability.
Notes:
A EDCB
3 3/4" [95MM]
23 3/4" [603MM]
24" [610MM]
23 3/4" [603MM]
24 3/8" [619MM]
Alternate Dimensions - 2x2
T5
T5HO
CFL
T8
CORELITE
maryi Text Box
R3WD-3T8-1D-UNV-22-T1
maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Text Box Must confirm wall box dimmers being used to coordinate with ballast maryi Line maryi Line
Comments
Prepared by
Type
Date
SPECIFICATION FEATURES
09/27/2012 7:55:00 PMConsult your representative for additional options and finishes.
Specifications and Dimensions subject to change without notice. ADE090286
DESCRIPTION
Corelite's latest addition to its line of shallow recessed fixtures, the Class R3, is the ultimate complement to the R1 and R2, offering the ideal combination of performance and aesthetics. The fully luminous housing of the R3 creates a high sense of style and superior brightness management, all while providing low watts per square foot to satisfy the most stringent energy requirements. To further realize the Class R series' design potential, the Class R3 is available with a complete palette of lamp options - including T8 and compact fluorescent - and maintains the series' dedication to shallow plenum applications with a minimal 3-3/4" deep housing.
A ... Construction Low profile housing constructed of die-formed 20 gauge cold rolled steel with integral 20 gauge gear tray.
B ... Reflectors Micro prismatic acrylic lens composed of frosted and clear blend.
C ... Shielding Extruded acrylic center optic with frosted acrylic side lenses. Perf pattern is silkscreened onto the surface of the inlay. Lens is secured to housing via injection molded inserts for easy lamp access.
D ... Electrical T8 fixtures use UL listed Class P, 265ma T8 instant start universal voltage electronic ballasts. Power factor of 95% with less than 10% THD. Fixtures and electrical components certified to UL and CUL standards.
E ... Finish Fixture housings are high reflectance white using electrostatically applied polyester powder coat paint.
Mounting Standard flange design works with most lay-in ceiling types. Integral pryout tabs secure luminaire to ceiling grid from above. Fixture offers tie-in locations for tie-wire on all corners, consult local code for appropriate tie-wire recommendations. Cannot mount more than four (4) fixtures continuously in one direction, or eight (8) fixtures total.
NOTE: Concealed Ceiling Class R may be installed into inaccessible ceilings (sheet rock, wood panel, etc.). This is achieved with the Metalux DFW series drywall frame-in kit, ordered separately from Metalux. Specify "CC" for the Corelite Ceiling Type.
Specify the following part numbers separately, from Metalux:
For 2x2, order Metalux part #
DF-22W-U
CLASS R3
Rectangular Perf
Inlay
Round Perf Inlay
3T8
2'x2' Recessed
3-3/4" Depth
ORDERING INFORMATION
Sample Number: R3-WG-3T8-1C-UNV-22-T1
Wiring 1
B Battery Pack=
C Standard Circuit=
D Dimming / Step Dimming=
E Emergency=
T Nightlight=
Y Daylight=
Options 1
AR Air Return=
CP Chicago Plenum=
SD Step Dimming=
W6 6' Whip Flex=
W12 12' Whip Flex=
Ceiling Type
T1 1" Grid, Slot-Grid, 9/16" Tegular
T9 9/16" Grid=
CC Concealed Ceiling=
SU Surface Mount=
Voltage 1
120 120V=
277 277V=
347 347V=
UNV Universal (120V-277V)
Lamp Type
T8 T8 Normal Output=
Shielding
D Round Perf Inlay=
G Rectangular Perf Inlay=
Series
R3 Class R3=
Number of Circuits
1 1 Circuit=
2 2 Circuits=
Reflector
W White= Number of Lamps
3 3 Lamps=
Size
22 2' x 2'=
1 Not all options available. Please consult your Cooper Lighting Representative for availability.
Notes:
A EDCB
3 3/4" [95MM]
23 3/4" [603MM]
24" [610MM]
23 3/4" [603MM]
24 3/8" [619MM]
Alternate Dimensions - 2x2
T5
T5HO
CFL
T8
CORELITE
maryi Text Box
R3WD-3T8-1C-UNV-22-T1-PRS
maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Text Box PRS- Program Start maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Line maryi Line maryi Line maryi Line
Comments
Prepared by
Type
Date
SPECIFICATION FEATURES
09/27/2012 7:55:00 PMConsult your representative for additional options and finishes.
Specifications and Dimensions subject to change without notice. ADE090286
DESCRIPTION
Corelite's latest addition to its line of shallow recessed fixtures, the Class R3, is the ultimate complement to the R1 and R2, offering the ideal combination of performance and aesthetics. The fully luminous housing of the R3 creates a high sense of style and superior brightness management, all while providing low watts per square foot to satisfy the most stringent energy requirements. To further realize the Class R series' design potential, the Class R3 is available with a complete palette of lamp options - including T8 and compact fluorescent - and maintains the series' dedication to shallow plenum applications with a minimal 3-3/4" deep housing.
A ... Construction Low profile housing constructed of die-formed 20 gauge cold rolled steel with integral 20 gauge gear tray.
B ... Reflectors Micro prismatic acrylic lens composed of frosted and clear blend.
C ... Shielding Extruded acrylic center optic with frosted acrylic side lenses. Perf pattern is silkscreened onto the surface of the inlay. Lens is secured to housing via injection molded inserts for easy lamp access.
D ... Electrical T8 fixtures use UL listed Class P, 265ma T8 instant start universal voltage electronic ballasts. Power factor of 95% with less than 10% THD. Fixtures and electrical components certified to UL and CUL standards.
E ... Finish Fixture housings are high reflectance white using electrostatically applied polyester powder coat paint.
Mounting Standard flange design works with most lay-in ceiling types. Integral pryout tabs secure luminaire to ceiling grid from above. Fixture offers tie-in locations for tie-wire on all corners, consult local code for appropriate tie-wire recommendations. Cannot mount more than four (4) fixtures continuously in one direction, or eight (8) fixtures total.
NOTE: Concealed Ceiling Class R may be installed into inaccessible ceilings (sheet rock, wood panel, etc.). This is achieved with the Metalux DFW series drywall frame-in kit, ordered separately from Metalux. Specify "CC" for the Corelite Ceiling Type.
Specify the following part numbers separately, from Metalux:
For 2x2, order Metalux part #
DF-22W-U
CLASS R3
Rectangular Perf
Inlay
Round Perf Inlay
3T8
2'x2' Recessed
3-3/4" Depth
ORDERING INFORMATION
Sample Number: R3-WG-3T8-1C-UNV-22-T1
Wiring 1
B Battery Pack=
C Standard Circuit=
D Dimming / Step Dimming=
E Emergency=
T Nightlight=
Y Daylight=
Options 1
AR Air Return=
CP Chicago Plenum=
SD Step Dimming=
W6 6' Whip Flex=
W12 12' Whip Flex=
Ceiling Type
T1 1" Grid, Slot-Grid, 9/16" Tegular
T9 9/16" Grid=
CC Concealed Ceiling=
SU Surface Mount=
Voltage 1
120 120V=
277 277V=
347 347V=
UNV Universal (120V-277V)
Lamp Type
T8 T8 Normal Output=
Shielding
D Round Perf Inlay=
G Rectangular Perf Inlay=
Series
R3 Class R3=
Number of Circuits
1 1 Circuit=
2 2 Circuits=
Reflector
W White= Number of Lamps
3 3 Lamps=
Size
22 2' x 2'=
1 Not all options available. Please consult your Cooper Lighting Representative for availability.
Notes:
A EDCB
3 3/4" [95MM]
23 3/4" [603MM]
24" [610MM]
23 3/4" [603MM]
24 3/8" [619MM]
Alternate Dimensions - 2x2
T5
T5HO
CFL
T8
CORELITE
maryi Text Box
R3WD-3T8-1C-UNV-22-T1-PRS-SD
maryi Text Box PRS - Program Start Ballast maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line
Comments
Prepared by
Type
Date
SPECIFICATION FEATURES
09/27/2012 7:55:00 PMConsult your representative for additional options and finishes.
Specifications and Dimensions subject to change without notice. ADE090286
DESCRIPTION
Corelite's latest addition to its line of shallow recessed fixtures, the Class R3, is the ultimate complement to the R1 and R2, offering the ideal combination of performance and aesthetics. The fully luminous housing of the R3 creates a high sense of style and superior brightness management, all while providing low watts per square foot to satisfy the most stringent energy requirements. To further realize the Class R series' design potential, the Class R3 is available with a complete palette of lamp options - including T8 and compact fluorescent - and maintains the series' dedication to shallow plenum applications with a minimal 3-3/4" deep housing.
A ... Construction Low profile housing constructed of die-formed 20 gauge cold rolled steel with integral 20 gauge gear tray.
B ... Reflectors Micro prismatic acrylic lens composed of frosted and clear blend.
C ... Shielding Extruded acrylic center optic with frosted acrylic side lenses. Perf pattern is silkscreened onto the surface of the inlay. Lens is secured to housing via injection molded inserts for easy lamp access.
D ... Electrical T8 fixtures use UL listed Class P, 265ma T8 instant start universal voltage electronic ballasts. Power factor of 95% with less than 10% THD. Fixtures and electrical components certified to UL and CUL standards.
E ... Finish Fixture housings are high reflectance white using electrostatically applied polyester powder coat paint.
Mounting Standard flange design works with most lay-in ceiling types. Integral pryout tabs secure luminaire to ceiling grid from above. Fixture offers tie-in locations for tie-wire on all corners, consult local code for appropriate tie-wire recommendations. Cannot mount more than four (4) fixtures continuously in one direction, or eight (8) fixtures total.
NOTE: Concealed Ceiling Class R may be installed into inaccessible ceilings (sheet rock, wood panel, etc.). This is achieved with the Metalux DFW series drywall frame-in kit, ordered separately from Metalux. Specify "CC" for the Corelite Ceiling Type.
Specify the following part numbers separately, from Metalux:
For 2x2, order Metalux part #
DF-22W-U
CLASS R3
Rectangular Perf
Inlay
Round Perf Inlay
3T8
2'x2' Recessed
3-3/4" Depth
ORDERING INFORMATION
Sample Number: R3-WG-3T8-1C-UNV-22-T1
Wiring 1
B Battery Pack=
C Standard Circuit=
D Dimming / Step Dimming=
E Emergency=
T Nightlight=
Y Daylight=
Options 1
AR Air Return=
CP Chicago Plenum=
SD Step Dimming=
W6 6' Whip Flex=
W12 12' Whip Flex=
Ceiling Type
T1 1" Grid, Slot-Grid, 9/16" Tegular
T9 9/16" Grid=
CC Concealed Ceiling=
SU Surface Mount=
Voltage 1
120 120V=
277 277V=
347 347V=
UNV Universal (120V-277V)
Lamp Type
T8 T8 Normal Output=
Shielding
D Round Perf Inlay=
G Rectangular Perf Inlay=
Series
R3 Class R3=
Number of Circuits
1 1 Circuit=
2 2 Circuits=
Reflector
W White= Number of Lamps
3 3 Lamps=
Size
22 2' x 2'=
1 Not all options available. Please consult your Cooper Lighting Representative for availability.
Notes:
A EDCB
3 3/4" [95MM]
23 3/4" [603MM]
24" [610MM]
23 3/4" [603MM]
24 3/8" [619MM]
Alternate Dimensions - 2x2
T5
T5HO
CFL
T8
CORELITE
maryi Text Box
R3WD-3T8-1B-IOTA-XXX-22-T1-PRS-SD
maryi Text Box XXX-Specify Operating Voltage for EM pack maryi Text Box PRS - Program Start Ballast maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Highlight
The I-320 from IOTA Engineering is a UL Listed fluorescent emergency ballast that allows the same fixture to be used for both normal and emergency operation. In the event of a power failure, the I-320 switches to the emergency mode and operates one of the existing lamps for 90 minutes. The unit contains a battery, charger, and inverter circuit in a single can, and can be mounted in the wireway or on top of the fixture.
The I-320 can be used with most 2′-4′ T8 lamps and 2′-4′ 14W to 54W T5 lamps, with an initial output of up to 1350 lumens for one lamp. The I-320 utilizes AC output to ensure compatibility with new lamp technologies, and features lamp selector leads for optimizing light output for the designated lamp type. The I-320 delivers high performance in a slim design, and is ideal for use in fixtures where ballast compartment space is limited. The I-320 is suitable for use in damp locations.
MODEL NO:
TYPE:
PROJECT:
COMMENTS:
Will cold start and operate all specified lamps
Long life high temperature recyclable
Ni-Cad battery
Galvanized steel case
Includes test switch and charge indicator accessory kit
For use with switched or unswitched fixtures
5-Year Warranty. See Warranty Page for details.
Suitable for use in damp locations
Selectable lamp leads optimize light output for desired lamp type
Meets or exceeds all National Electrical Code and Life Safety Code Emergency Lighting
Requirements
International Voltage models available
IOTA REV 012014
DESCRIPTION:
FEATURES
IOTA ENGINEERING
Input Voltage ............................................................. (Dual) 120/277V, 60Hz
Input Wattage ................................................................................ 3.5 Watts
Lamps Operated ...................................................Most 2′-4′ single, bipin T8 HO or VHO fluorescent lamps and 2′-4′ 14W to 54W T5 lamps
Emergency Operation* .............................................................. 90 minutes
Initial Illumination ............................................. (1) lamp up to 1350 lumens
Operating Temp ...........................................................................0° to 50° C
Battery .............................................................................24 Hour Recharge 7-10 Year Life Expectancy
Weight .............................................................................................. 2.5 lbs.
Approval ..................................................................UL and CUL 924 Listed
TECHNICAL SPECIFICATIONS
CASE DIMENSIONS
Reduced Profile design is ideal for smaller ballast compartments
AC Output for compatibility with low mercury content amalgam lamps
Time Delay feature for compatibility with End-of-Lamp-Life circuitry
Open Circuit Isolation protects unit when load is absent
13.0″ x 2.2″ x 1.25″ (mounting center 12.6″)
PRODUCT ADVANTAGES
Most 2′-4′ single, bipin, T8 HO or VHO and 2′-4′ 14W to 54W T5 fluorescent lamps
LAMPS OPERATED*
LENGTH 13.0"
MOUNTING CENTER 12.6"
HEIGHT
1.25"
WIDTH 2.2"
I-320 PRODUCT SPECIFICATION SHEET
*Refer to Lumen Reference Chart for list of compatible lamps
P.O. BOX 11846 TUCSON, AZ 85734
(520) 294-3292 • FAX (520) 741-2837
www.iotaengineering.com http://www.iotaengineering.com maryi Highlight
OPTIONS
TBTS (STANDARD)
TWO-PIECE TEST SWITCH AND CHARGE INDICATOR
CONFIGURATION
120/277V 60HZ (STANDARD)
220V 50HZ
240V 60HZ
120V 50HZ
VOLTAGE RATINGS
When battery packs are remote mounted, consult Customer Service for the maximum allowable distance between the battery pack and lamp(s).
REMOTE MOUNTING
IOTA REV 012014
AVERAGE LUMEN RATINGS
Emergency lighting shall be provided by using a standard fluorescent fix-ture equipped with an IOTA I-320 fluorescent emergency battery pack. The
I-320 shall consist of a high temperature, maintenance-free nickel cad-mium battery, charger board and an electronic circuit enclosed in a 13.0″ x 2.2″ x 1.25″ vandal-resistant steel case for installation in the wireway or on top of the fixture. A combination one piece long-life LED charge indica-tor light and test switch shall be included. The fluorescent EM pack shall operate one 14w-54w T5 (2′-4′) or 17w-32w (2′-4′) T8 fluorescent lamp. The
I-320 shall provide reduced illumination for a minimum of 90 minutes in the emer-gency mode with a total initial output of 1350 lumens. The I-320 will operate the lamp with AC output and will feature selectable lamp leads for optimizing light output for the designated lamp type. The I-320 shall have 3.5 watts of input power and a battery capacity of 24 watt hours. The I-320 is UL Listed and meets or exceeds all NEC and Life Safety Code Emergency Lighting Requirements, and rated for use in damp locations. The I-320 is warranted for a full five (5) years from the date of purchase.
I-320 SAMPLE SPECIFICATION
Emergency lighting shall be provided by using a standard fluorescent fixture equipped with an integral fluorescent emergency battery pack. The EM pack shall consist of a high temperature, maintenance-free nickel cadmium battery, charger board and an electronic circuit enclosed in a steel case for installation either inside the wireway or on top of the fixture. A long-life LED charge indicator light and test switch shall be included. The fluorescent EM pack shall operate one 14w-54w T5 (2′-4′) or 17w-32w (2′-4′) T8 fluorescent lamp. The EM pack shall provide reduced illumination for a minimum of 90 minutes in the emergency mode with a total initial output of 1350 lumens. The I-320 will operate the lamp with AC output and will feature selectable lamp leads for optimizing light output for the designated lamp type. The unit shall have 3.5 watts of input power and a battery capacity of 24 watt hours. The EM pack must be UL Listed and meet or exceed all NEC and Life Safety Code Emergency Lighting Requirements, and rated for use in damp locations. All product shall be warranted for a full five (5) years from the date of purchase.
1200 LUMEN SAMPLE SPECIFICATION
I-320
REDUCED PROFILE FLUORESCENT EMERGENCY BALLAST
IOTA ENGINEERING PO BOX 11846 TUCSON, AZ 85734 TEL: 1-800-866-IOTA (4682) FAX: (520) 741-2837 WEB: www.iotaengineering.com
LAMP
F17 T8 F25 T8 F28 T8 F32 T8 14W T5 21W T5 24W T5 28W T5 39W T5 54W T5 13W PL CF 4-Pin 18W PL CF Quad 4-Pin 26W PL CF Quad 4-Pin 32W PL CF Quad 4-Pin 42W PL CF Quad 4-Pin
1 LAMP
maryi Text Box 120V Operating Voltage maryi Line
Comments
Prepared by
Type
Date
SPECIFICATION FEATURES
09/27/2012 7:55:00 PMConsult your representative for additional options and finishes.
Specifications and Dimensions subject to change without notice. ADE090286
DESCRIPTION
Corelite's latest addition to its line of shallow recessed fixtures, the Class R3, is the ultimate complement to the R1 and R2, offering the ideal combination of performance and aesthetics. The fully luminous housing of the R3 creates a high sense of style and superior brightness management, all while providing low watts per square foot to satisfy the most stringent energy requirements. To further realize the Class R series' design potential, the Class R3 is available with a complete palette of lamp options - including T8 and compact fluorescent - and maintains the series' dedication to shallow plenum applications with a minimal 3-3/4" deep housing.
A ... Construction Low profile housing constructed of die-formed 20 gauge cold rolled steel with integral 20 gauge gear tray.
B ... Reflectors Micro prismatic acrylic lens composed of frosted and clear blend.
C ... Shielding Extruded acrylic center optic with frosted acrylic side lenses. Perf pattern is silkscreened onto the surface of the inlay. Lens is secured to housing via injection molded inserts for easy lamp access.
D ... Electrical T8 fixtures use UL listed Class P, 265ma T8 instant start universal voltage electronic ballasts. Power factor of 95% with less than 10% THD. Fixtures and electrical components certified to UL and CUL standards.
E ... Finish Fixture housings are high reflectance white using electrostatically applied polyester powder coat paint.
Mounting Standard flange design works with most lay-in ceiling types. Integral pryout tabs secure luminaire to ceiling grid from above. Fixture offers tie-in locations for tie-wire on all corners, consult local code for appropriate tie-wire recommendations. Cannot mount more than four (4) fixtures continuously in one direction, or eight (8) fixtures total.
NOTE: Concealed Ceiling Class R may be installed into inaccessible ceilings (sheet rock, wood panel, etc.). This is achieved with the Metalux DFW series drywall frame-in kit, ordered separately from Metalux. Specify "CC" for the Corelite Ceiling Type.
Specify the following part numbers separately, from Metalux:
For 2x2, order Metalux part #
DF-22W-U
CLASS R3
Rectangular Perf
Inlay
Round Perf Inlay
3T8
2'x2' Recessed
3-3/4" Depth
ORDERING INFORMATION
Sample Number: R3-WG-3T8-1C-UNV-22-T1
Wiring 1
B Battery Pack=
C Standard Circuit=
D Dimming / Step Dimming=
E Emergency=
T Nightlight=
Y Daylight=
Options 1
AR Air Return=
CP Chicago Plenum=
SD Step Dimming=
W6 6' Whip Flex=
W12 12' Whip Flex=
Ceiling Type
T1 1" Grid, Slot-Grid, 9/16" Tegular
T9 9/16" Grid=
CC Concealed Ceiling=
SU Surface Mount=
Voltage 1
120 120V=
277 277V=
347 347V=
UNV Universal (120V-277V)
Lamp Type
T8 T8 Normal Output=
Shielding
D Round Perf Inlay=
G Rectangular Perf Inlay=
Series
R3 Class R3=
Number of Circuits
1 1 Circuit=
2 2 Circuits=
Reflector
W White= Number of Lamps
3 3 Lamps=
Size
22 2' x 2'=
1 Not all options available. Please consult your Cooper Lighting Representative for availability.
Notes:
A EDCB
3 3/4" [95MM]
23 3/4" [603MM]
24" [610MM]
23 3/4" [603MM]
24 3/8" [619MM]
Alternate Dimensions - 2x2
T5
T5HO
CFL
T8
CORELITE
maryi Text Box
R3WD-3T8-1B-IOTA-XXX-22-T1-PRS-SD
maryi Text Box 120V Operating Voltage for EM pack maryi Text Box PRS - Program Start Ballast maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Highlight
Comments
Prepared by
Type
Date
SPECIFICATION FEATURES
09/27/2012 7:55:00 PMConsult your representative for additional options and finishes.
Specifications and Dimensions subject to change without notice. ADE090286
DESCRIPTION
Corelite's latest addition to its line of shallow recessed fixtures, the Class R3, is the ultimate complement to the R1 and R2, offering the ideal combination of performance and aesthetics. The fully luminous housing of the R3 creates a high sense of style and superior brightness management, all while providing low watts per square foot to satisfy the most stringent energy requirements. To further realize the Class R series' design potential, the Class R3 is available with a complete palette of lamp options - including T8 and compact fluorescent - and maintains the series' dedication to shallow plenum applications with a minimal 3-3/4" deep housing.
A ... Construction Low profile housing constructed of die-formed 20 gauge cold rolled steel with integral 20 gauge gear tray.
B ... Reflectors Micro prismatic acrylic lens composed of frosted and clear blend.
C ... Shielding Extruded acrylic center optic with frosted acrylic side lenses. Perf pattern is silkscreened onto the surface of the inlay. Lens is secured to housing via injection molded inserts for easy lamp access.
D ... Electrical T8 fixtures use UL listed Class P, 265ma T8 instant start universal voltage electronic ballasts. Power factor of 95% with less than 10% THD. Fixtures and electrical components certified to UL and CUL standards.
E ... Finish Fixture housings are high reflectance white using electrostatically applied polyester powder coat paint.
Mounting Standard flange design works with most lay-in ceiling types. Integral pryout tabs secure luminaire to ceiling grid from above. Fixture offers tie-in locations for tie-wire on all corners, consult local code for appropriate tie-wire recommendations. Cannot mount more than four (4) fixtures continuously in one direction, or eight (8) fixtures total.
NOTE: Concealed Ceiling Class R may be installed into inaccessible ceilings (sheet rock, wood panel, etc.). This is achieved with the Metalux DFW series drywall frame-in kit, ordered separately from Metalux. Specify "CC" for the Corelite Ceiling Type.
Specify the following part numbers separately, from Metalux:
For 2x2, order Metalux part #
DF-22W-U
CLASS R3
Rectangular Perf
Inlay
Round Perf Inlay
3T8
2'x2' Recessed
3-3/4" Depth
ORDERING INFORMATION
Sample Number: R3-WG-3T8-1C-UNV-22-T1
Wiring 1
B Battery Pack=
C Standard Circuit=
D Dimming / Step Dimming=
E Emergency=
T Nightlight=
Y Daylight=
Options 1
AR Air Return=
CP Chicago Plenum=
SD Step Dimming=
W6 6' Whip Flex=
W12 12' Whip Flex=
Ceiling Type
T1 1" Grid, Slot-Grid, 9/16" Tegular
T9 9/16" Grid=
CC Concealed Ceiling=
SU Surface Mount=
Voltage 1
120 120V=
277 277V=
347 347V=
UNV Universal (120V-277V)
Lamp Type
T8 T8 Normal Output=
Shielding
D Round Perf Inlay=
G Rectangular Perf Inlay=
Series
R3 Class R3=
Number of Circuits
1 1 Circuit=
2 2 Circuits=
Reflector
W White= Number of Lamps
3 3 Lamps=
Size
22 2' x 2'=
1 Not all options available. Please consult your Cooper Lighting Representative for availability.
Notes:
A EDCB
3 3/4" [95MM]
23 3/4" [603MM]
24" [610MM]
23 3/4" [603MM]
24 3/8" [619MM]
Alternate Dimensions - 2x2
T5
T5HO
CFL
T8
CORELITE
maryi Text Box
R3WD-3T8-1B-IOTA320-XXX-22-T1-PRS
maryi Text Box XXX-Specify Operating Voltage for EM Pack maryi Text Box PRS- Program Start Ballast maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line
The I-320 from IOTA Engineering is a UL Listed fluorescent emergency ballast that allows the same fixture to be used for both normal and emergency operation. In the event of a power failure, the I-320 switches to the emergency mode and operates one of the existing lamps for 90 minutes. The unit contains a battery, charger, and inverter circuit in a single can, and can be mounted in the wireway or on top of the fixture.
The I-320 can be used with most 2′-4′ T8 lamps and 2′-4′ 14W to 54W T5 lamps, with an initial output of up to 1350 lumens for one lamp. The I-320 utilizes AC output to ensure compatibility with new lamp technologies, and features lamp selector leads for optimizing light output for the designated lamp type. The I-320 delivers high performance in a slim design, and is ideal for use in fixtures where ballast compartment space is limited. The I-320 is suitable for use in damp locations.
MODEL NO:
TYPE:
PROJECT:
COMMENTS:
Will cold start and operate all specified lamps
Long life high temperature recyclable
Ni-Cad battery
Galvanized steel case
Includes test switch and charge indicator accessory kit
For use with switched or unswitched fixtures
5-Year Warranty. See Warranty Page for details.
Suitable for use in damp locations
Selectable lamp leads optimize light output for desired lamp type
Meets or exceeds all National Electrical Code and Life Safety Code Emergency Lighting
Requirements
International Voltage models available
IOTA REV 012014
DESCRIPTION:
FEATURES
IOTA ENGINEERING
Input Voltage ............................................................. (Dual) 120/277V, 60Hz
Input Wattage ................................................................................ 3.5 Watts
Lamps Operated ...................................................Most 2′-4′ single, bipin T8 HO or VHO fluorescent lamps and 2′-4′ 14W to 54W T5 lamps
Emergency Operation* .............................................................. 90 minutes
Initial Illumination ............................................. (1) lamp up to 1350 lumens
Operating Temp ...........................................................................0° to 50° C
Battery .............................................................................24 Hour Recharge 7-10 Year Life Expectancy
Weight .............................................................................................. 2.5 lbs.
Approval ..................................................................UL and CUL 924 Listed
TECHNICAL SPECIFICATIONS
CASE DIMENSIONS
Reduced Profile design is ideal for smaller ballast compartments
AC Output for compatibility with low mercury content amalgam lamps
Time Delay feature for compatibility with End-of-Lamp-Life circuitry
Open Circuit Isolation protects unit when load is absent
13.0″ x 2.2″ x 1.25″ (mounting center 12.6″)
PRODUCT ADVANTAGES
Most 2′-4′ single, bipin, T8 HO or VHO and 2′-4′ 14W to 54W T5 fluorescent lamps
LAMPS OPERATED*
LENGTH 13.0"
MOUNTING CENTER 12.6"
HEIGHT
1.25"
WIDTH 2.2"
I-320 PRODUCT SPECIFICATION SHEET
*Refer to Lumen Reference Chart for list of compatible lamps
P.O. BOX 11846 TUCSON, AZ 85734
(520) 294-3292 • FAX (520) 741-2837
www.iotaengineering.com http://www.iotaengineering.com maryi Highlight
OPTIONS
TBTS (STANDARD)
TWO-PIECE TEST SWITCH AND CHARGE INDICATOR
CONFIGURATION
120/277V 60HZ (STANDARD)
220V 50HZ
240V 60HZ
120V 50HZ
VOLTAGE RATINGS
When battery packs are remote mounted, consult Customer Service for the maximum allowable distance between the battery pack and lamp(s).
REMOTE MOUNTING
IOTA REV 012014
AVERAGE LUMEN RATINGS
Emergency lighting shall be provided by using a standard fluorescent fix-ture equipped with an IOTA I-320 fluorescent emergency battery pack. The
I-320 shall consist of a high temperature, maintenance-free nickel cad-mium battery, charger board and an electronic circuit enclosed in a 13.0″ x 2.2″ x 1.25″ vandal-resistant steel case for installation in the wireway or on top of the fixture. A combination one piece long-life LED charge indica-tor light and test switch shall be included. The fluorescent EM pack shall operate one 14w-54w T5 (2′-4′) or 17w-32w (2′-4′) T8 fluorescent lamp. The
I-320 shall provide reduced illumination for a minimum of 90 minutes in the emer-gency mode with a total initial output of 1350 lumens. The I-320 will operate the lamp with AC output and will feature selectable lamp leads for optimizing light output for the designated lamp type. The I-320 shall have 3.5 watts of input power and a battery capacity of 24 watt hours. The I-320 is UL Listed and meets or exceeds all NEC and Life Safety Code Emergency Lighting Requirements, and rated for use in damp locations. The I-320 is warranted for a full five (5) years from the date of purchase.
I-320 SAMPLE SPECIFICATION
Emergency lighting shall be provided by using a standard fluorescent fixture equipped with an integral fluorescent emergency battery pack. The EM pack shall consist of a high temperature, maintenance-free nickel cadmium battery, charger board and an electronic circuit enclosed in a steel case for installation either inside the wireway or on top of the fixture. A long-life LED charge indicator light and test switch shall be included. The fluorescent EM pack shall operate one 14w-54w T5 (2′-4′) or 17w-32w (2′-4′) T8 fluorescent lamp. The EM pack shall provide reduced illumination for a minimum of 90 minutes in the emergency mode with a total initial output of 1350 lumens. The I-320 will operate the lamp with AC output and will feature selectable lamp leads for optimizing light output for the designated lamp type. The unit shall have 3.5 watts of input power and a battery capacity of 24 watt hours. The EM pack must be UL Listed and meet or exceed all NEC and Life Safety Code Emergency Lighting Requirements, and rated for use in damp locations. All product shall be warranted for a full five (5) years from the date of purchase.
1200 LUMEN SAMPLE SPECIFICATION
I-320
REDUCED PROFILE FLUORESCENT EMERGENCY BALLAST
IOTA ENGINEERING PO BOX 11846 TUCSON, AZ 85734 TEL: 1-800-866-IOTA (4682) FAX: (520) 741-2837 WEB: www.iotaengineering.com
LAMP
F17 T8 F25 T8 F28 T8 F32 T8 14W T5 21W T5 24W T5 28W T5 39W T5 54W T5 13W PL CF 4-Pin 18W PL CF Quad 4-Pin 26W PL CF Quad 4-Pin 32W PL CF Quad 4-Pin 42W PL CF Quad 4-Pin
1 LAMP
maryi Text Box 120V Operating Voltage
Comments
Prepared by
Type
Date
SPECIFICATION FEATURES
09/27/2012 7:55:00 PMConsult your representative for additional options and finishes.
Specifications and Dimensions subject to change without notice. ADE090286
DESCRIPTION
Corelite's latest addition to its line of shallow recessed fixtures, the Class R3, is the ultimate complement to the R1 and R2, offering the ideal combination of performance and aesthetics. The fully luminous housing of the R3 creates a high sense of style and superior brightness management, all while providing low watts per square foot to satisfy the most stringent energy requirements. To further realize the Class R series' design potential, the Class R3 is available with a complete palette of lamp options - including T8 and compact fluorescent - and maintains the series' dedication to shallow plenum applications with a minimal 3-3/4" deep housing.
A ... Construction Low profile housing constructed of die-formed 20 gauge cold rolled steel with integral 20 gauge gear tray.
B ... Reflectors Micro prismatic acrylic lens composed of frosted and clear blend.
C ... Shielding Extruded acrylic center optic with frosted acrylic side lenses. Perf pattern is silkscreened onto the surface of the inlay. Lens is secured to housing via injection molded inserts for easy lamp access.
D ... Electrical T8 fixtures use UL listed Class P, 265ma T8 instant start universal voltage electronic ballasts. Power factor of 95% with less than 10% THD. Fixtures and electrical components certified to UL and CUL standards.
E ... Finish Fixture housings are high reflectance white using electrostatically applied polyester powder coat paint.
Mounting Standard flange design works with most lay-in ceiling types. Integral pryout tabs secure luminaire to ceiling grid from above. Fixture offers tie-in locations for tie-wire on all corners, consult local code for appropriate tie-wire recommendations. Cannot mount more than four (4) fixtures continuously in one direction, or eight (8) fixtures total.
NOTE: Concealed Ceiling Class R may be installed into inaccessible ceilings (sheet rock, wood panel, etc.). This is achieved with the Metalux DFW series drywall frame-in kit, ordered separately from Metalux. Specify "CC" for the Corelite Ceiling Type.
Specify the following part numbers separately, from Metalux:
For 2x2, order Metalux part #
DF-22W-U
CLASS R3
Rectangular Perf
Inlay
Round Perf Inlay
3T8
2'x2' Recessed
3-3/4" Depth
ORDERING INFORMATION
Sample Number: R3-WG-3T8-1C-UNV-22-T1
Wiring 1
B Battery Pack=
C Standard Circuit=
D Dimming / Step Dimming=
E Emergency=
T Nightlight=
Y Daylight=
Options 1
AR Air Return=
CP Chicago Plenum=
SD Step Dimming=
W6 6' Whip Flex=
W12 12' Whip Flex=
Ceiling Type
T1 1" Grid, Slot-Grid, 9/16" Tegular
T9 9/16" Grid=
CC Concealed Ceiling=
SU Surface Mount=
Voltage 1
120 120V=
277 277V=
347 347V=
UNV Universal (120V-277V)
Lamp Type
T8 T8 Normal Output=
Shielding
D Round Perf Inlay=
G Rectangular Perf Inlay=
Series
R3 Class R3=
Number of Circuits
1 1 Circuit=
2 2 Circuits=
Reflector
W White= Number of Lamps
3 3 Lamps=
Size
22 2' x 2'=
1 Not all options available. Please consult your Cooper Lighting Representative for availability.
Notes:
A EDCB
3 3/4" [95MM]
23 3/4" [603MM]
24" [610MM]
23 3/4" [603MM]
24 3/8" [619MM]
Alternate Dimensions - 2x2
T5
T5HO
CFL
T8
CORELITE
maryi Text Box
R3WD-3T8-1B-IOTA320-XXX-22-T1-PRS
maryi Text Box 120 V Operating Voltage for EM Pack maryi Text Box PRS- Program Start Ballast maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Highlight maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line maryi Line
T (800) 236-6800 F (262) 504-5415US: www.cree.com/lighting T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada
CR22™ with Cree SmartCast™ Technology 2'x2' Architectural LED Troffer
24" (603mm)
24" (603mm)
Rev. Date 02/11/2014
4.7" (119mm)
CR22™Product Description The CR22™ Architectural LED troffer with Cree SmartCast™ Technology delivers exceptional lighting performance combined with simple lighting controls that are easy to use and install. Cree SmartCast™ Technology products incorporate integrated ambient and occupancy sensing and wireless communication to achieve energy savings and extended product life resulting in lower electricity bills, reduced maintenance, and an improved total cost of ownership over traditional lighting control systems.
Performance Summary
Utilizes Cree TrueWhite® Technology
Active Color Management
Room-Side Heat Sink
Assembled in the US
Efficacy: 100 LPW
Delivered Light Output: 3,200 lumens
Input Power: 32 watts
CRI: 90 CRI
CCT: 3000K, 3500K, 4000K, 5000K
Input Voltage: 120-277 VAC
Limited Warranty: 5 Years†
Lifetime: Designed to last 75,000 hours (Standard TW)
Controls: Integral ambient light and motion sensors
Mounting: Recessed
Ordering Information Example: CR22-32L-35K-CMA
CR22™
Product Lumen Output Color Temp Voltage Control
CR22 32L
32W 3,200 lumens – 100 LPW
30K 3000 Kelvin 35K 3500 Kelvin 40K 4000 Kelvin 50K 5000 Kelvin
Blank 120-277 Volt (Standard)
CMA
Controls ready with integral motion and ambient sensors.
Compatible with control modules listed below.
†See www.cree.com/lighting for warranty terms.
Control Modules
CM-CWC-1
Cree SmartCast™ Technology wireless control module (factory installed) www.cree.com/lighting
T (800) 236-6800 F (262) 504-5415US: www.cree.com/lighting T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada
Zonal Lumen Summary
Zone Lumens % Lamp Luminaire
0-30 923 N/A 28.1%
0-40 1527 N/A 46.5%
0-60 2704 N/A 82.5%
0-90 3280 N/A 100%
Average Luminance Table (cd/m2)
Horizontal Angle
V er ti ca l A ng le
0° 45° 90°
0° 3,864 3,864 3,864
45° 3,575 3,864 3,972
55° 3,164 3,656 3,758
65° 2,498 3,133 3,347
75° 1,620 2,348 2,051
85° 366 252 168 Reference www.cree.com/lighting for detailed photometric data.
Photometry
CR22™ BASED ON LTL REPORT TEST #: 24292
Coefficients Of Utilization
RCC %: 80
RW %: 70 50 30 10
RCR: 0 119 119 119 119
1 110 105 101 98
2 100 92 85 80
3 91 81 73 67
4 84 72 63 57
5 77 64 55 49
6 71 58 49 43
7 66 52 44 38
8 61 48 39 33
9 57 44 36 30
10 53 40 32 27
Effective Floor Cavity Reflectance: 20%
0 15 30
0° 90°
Open Space
Spacing Lumens Wattage LPW w/ft2 Average fc
8 x 8 2,000L 22W 90 0.35 28
3,200L 32W 100 0.55 44
8 x 10 2,000L 22W 90 0.28 23
3,200L 32W 100 0.44 37
10 x 10 2,000L 22W 90 0.22 20
3,200L 32W 100 0.35 31
10 x 12 2,000L 22W 90 0.19 16
3,200L 32W 100 0.29 25
9' ceiling: 80/50/20 reflectances; 2.5' workplane, open room LLF: 1.0 Initial.
Open Space: 50' x 40' x 10'
Application Reference
CR22™ with Cree SmartCast™ Technology
Product Specifications
CREE SMARTCAST™ TECHNOLOGY
Cree SmartCast™ Technology changes the paradigm of lighting control. With the press of a single button, Cree SmartCast™ Technology enabled luminaires and controls create their own secure network and auto-associate to form logical groups throughout every space. Integrated sensors and robust wireless communication included in every luminaire combined with revolutionary OneButton ™ Setup enables automated setup and configuration of luminaires and wall controls. With no extra wires or interfaces, Cree SmartCast™ Technology products reduce installation time and complexity.
CREE TRUEWHITE® TECHNOLOGY
A revolutionary way to generate high-quality white light, Cree TrueWhite® Technology is a patented approach that delivers an exclusive combination of 90+ CRI, beautiful light characteristics, and lifelong consistency, all while maintaining high luminous efficacy − a true no compromise solution.
ROOM-SIDE HEAT SINK
An innovative thermal management system designed to maximize cooling effectiveness by integrating a unique room-side heat sink into the diffusing lens. This breakthrough design creates a pleasing architectural aesthetic while conducting heat away from LEDs in a temperature-controlled environment.
This enables the LEDs to consistently run cooler, providing significant boosts to lifetime, efficacy, and color consistency.
LUMEN MAINTENANCE FACTORS
• Reference www.cree.com/lighting for detailed lumen maintenance factors.
CONSTRUCTION & MATERIALS
• Durable 20-gauge steel housing with standard troffer access plate for electrical installation.
• Field replaceable light engine integrates LEDs, driver, power supply, thermal management, and optical mixing components.
• One-piece lower reflector finished with a textured high reflectance white polyester powder coating creates a comfortable visual transition from the lens to the ceiling plane.
• Provided t-bar clips and holes for mounting support wires enable recessed or suspended installation.
NOTE: Reference www.cree.com/lighting for detailed instructions on field replacement of the light engine.
OPTICAL SYSTEM
• Unique combination of reflective and refractive optical components achieves a uniform, comfortable appearance while eliminating pixelation and color fringing.
• Components work together to optimize distribution, balancing the delivery of high illuminance levels on horizontal surfaces with an ideal amount of light on walls and vertical surfaces. This increases the perception of spaciousness.
• Diffusing lens integrated with upward-facing LED strip eliminates direct view of LEDs while lower reflector balances brightness of lens with the ceiling to create a low-glare high angle appearance.
ELECTRICAL SYSTEM
• Integral, high-efficiency driver and power supply.
• Power Factor = 0.9 nominal
• Input Voltage: 120-277V, 50/60Hz
• Temperature Rating: Designed to operate in temperatures 0-35 C and below room side and plenum side.
• Total Harmonic Distortion: < 20%
• Dimming: 5% - 100%
REGULATORY & VOLUNTARY QUALIFICATIONS
• cULus Listed.
• DLC qualified.
• Suitable for damp locations.
• Designed for Indoor use.
INTEGRAL MOTION SENSOR
• Passive infrared (PIR).
• Coverage area: 100 sq. ft. at 10 ft. mounting height.
• Not intended to be mounted higher than 12 ft.
INTEGRAL AMBIENT LIGHT SENSOR
• Sensor response matches response of human eye.
• Not intended to be mounted higher than 12 ft.
www.cree.com/lighting
T (800) 236-6800 F (262) 504-5415US: www.cree.com/lighting T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada
© 2014 Cree, Inc. and/or one of its subsidiaries. All rights reserved. For informational purposes only. See www.cree.com/patents for patents that cover these products. Cree®, the Cree logo, Cree TrueWhite®, TrueWhite® and the Cree TrueWhite Technology logo are registered trademarks and CR22TM, SmartCast™, the SmartCast logo, and OneButton™ are trademarks of Cree, Inc. The UL logo is a registered trademark of UL LLC.
Cree SmartCast™ Technology
INTEGRAL OCCUPANCY SENSOR
• Operation:
• Grouped with a wall control: Luminaire will operate in vacancy mode (manual-on/auto-off).
• Not grouped with a wall control: Luminare will operate in occupancy mode (auto-on/auto-off).
• Luminaires operate at full intensity until OneButton™ Setup is initiated by the Cree™ Configuration Tool.
INTEGRAL AMBIENT LIGHT SENSOR
• Luminaires operate at full intensity until OneButton™ Setup is initiated by the Cree Configuration Tool.
• Daylight harvesting calibration performed automatically during OneButton™ Setup.
INTEGRAL WIRELESS COMMUNICATION
• 2.4GHz wireless mesh technology with AES 128-bit encryption.
• Self assigns to quietest channel during OneButton™ Setup.
• Range:
• 30 ft. in typical commercial applications.
• 300 ft. open air without obstructions.
• Network: 250 devices max.
• Space: 100 devices max. per group.
• FCC certified.
• IC certified.
LUMINAIRE
• Luminaires operate at full intensity until OneButton™ Setup is initiated by the Cree Configuration Tool.
• 10 year power fail memory of settings.
CR22™ with Cree SmartCast™ Technology
Catalog # Type
Date
Project
Comments
Prepared by
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO
LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of disconnecting power.
COOPER LIGHTING - METALUX®
G R 8 F lat, White Steel ( White L atches)
11-3/4" [298mm]
3-3/4"
[95mm]
C E I L I N G C O M P A T I B I L I T Y
COOPER LIGHTING
DESCRIPT ION
The GR8 is a T8-dedicated lensed troffer designed to offer premium performance in a…