Plans - Amendment 3.pdf

PDF 8 MB Posted

Attached to
Construction of New Dormitory in Thule Air Base, Greenland
Solicitation number
W912DS-12-B-0002
Issued by

About this file

PLANS

View the file

Other files

File Type Posted
Amendment 0009.pdf PDF
Appendix L - DBA Waiver.pdf PDF
Plans - Amendment 8.pdf PDF
W912DS-12-B-0002 Amend 08.pdf PDF
Appendix J - Flight Schedule —
Appendix G - GeoTechnical Report - Amendment 7.pdf PDF
Price Schedule Addendum - Amendment 7.pdf PDF
Appendix K - Shipping Rates Gov Furnished Transport - Amendment 7.pdf PDF
W912DS-12-B-0002 Amend 07.pdf PDF
Appendix I - Governing Foundation Loads - Amendment 7.pdf PDF
Appendix H - NFS Material Borrow Site - Amendment 7.pdf PDF
WBS Thule Dormitory - Amendment 7.pdf PDF
W912DS-12-B-0002 Amend 06.pdf PDF
Plans - Amendment 5.pdf PDF
Reference to Question 4 - Amendment 5.pdf PDF
W912DS-12-B-0002 Amend 05.pdf PDF
Plans - Amendment 4.pdf PDF
W912DS-12-B-0002 Amend 04.pdf PDF
MTOC - Amendment 3.pdf PDF
11 13 13 - Amendment 3.pdf PDF
W912DS-12-B-0002 Amendment 0003.pdf PDF
Submittal Register - Amendment 3.pdf PDF
13 48 00.00 10 - Amendment 3.pdf PDF
Plans - Amendment 2.pdf PDF
Flight Schedule 01 Oct 11 - 30 Sep 12 - Amendment 2.pdf PDF
28 31 76 - Amendment 2.pdf PDF
2012 Shipping Schedule - Amendment 2.pdf PDF
DLA Fuel Pricing - Amendment 2.pdf PDF
21 13 13.00 10 - Amendment 2.pdf PDF
W912DS-12-B-0002 Amend 02.pdf PDF
W912DS-12-B-0002 Amend 01.pdf PDF
Package 3 - Thule Dorm CID - 100 .pdf PDF
Appendix A - Active Landfills.pdf PDF
Package 1 - Thule Dorm Plans - 100 .pdf PDF
Appendix E - CEV-15J Slug Mgmt Plan.pdf PDF
Package 2 - Thule Dorm Specification - 100 .pdf PDF
Appendix C - CEV-15C Spill Prevention-Response Plan.pdf PDF
Appendix F - Final Governing Standards for Environmental Protection for US Forces in Greenland.pdf PDF
Appendix B - CEV-15B HWM Plan.pdf PDF
Appendix D - CEV-15E Solid Waste Mgmt Plan.pdf PDF
W912DS-12-B-0002.pdf PDF
Show all 41

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Ja n

FIRST FLOOR

102100

SECOND FLOOR

105960

BOTTOM OF BLDG.

100844

THIRD FLOOR

109820

BOTTOM CHORD OF

TRUSS

113430

GRADE

99844

12345671011121314151617 89 8.1

A-201 A-202

A-101A A-202

FIRST FLOOR

102100

SECOND FLOOR

105960

BOTTOM OF BLDG.

100844

THIRD FLOOR

109820

BOTTOM CHORD OF

TRUSS

113430

GRADE

99844

1 2 3 4 5 6 7 10 11 12 13 14 15 16 178 9 A-101B A-203

1 A-101A A-203

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

D

AT

E:

SC

A L

E:

D R

A W

IN

G C

O D

E :

D

ES

IG

N

ED

BY

D R

A W N

BY

C H

E C

KE

D

BY

IS

S U

E D

AT

E:

D

AT

E:

EN

G

IN

EE

R

/A R

C H

IT

EC

T N

AM

E

PR

O

JE

C

T

EN

G

IN

EE

R

/A R

C H

IT

EC

T

U .S

.A R

M Y

EN

G

IN

EE

R D

IS

TR

IC

T

C O

R

PS

O F

EN

G

IN

EE

R S

N

EW

YO

R

K D

IS

TR

IC

T, N Y

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH: C:\Documents and Settings\E3ENDNMW\My Documents\ARCH_FY12_Thule_Dorm_V7_Central_File_Modular_E3ENDNMW.rvt

1/19/2012 6:03:54 PM

A-201

D es ig ne r Au th or

C h e ck er

FY

D

O R

M

IT

O R

Y, T

H U

LE

A

FB

, G

R

EE

N

LA

N D

EX

TE

R

IO

R

EL

EV

AT

IO

N

S

0 10,000MM 20,000MM

1 : 200A-201A-101A

NORTH1

1 : 200A-201A-101A

SOUTH2

3 3

3 3

3 3

33 3 3 3 3

3 3 3

33 3 3 3 3

AM

EN

D

M

EN

T

J

A N

Ja

SECOND FLOOR

105960

BOTTOM OF BLDG.

100844

THIRD FLOOR

109820

BOTTOM CHORD OF

TRUSS

113430

GRADE

99844

A-301

A-304

A-302

1011121314151617 89

TYP.

5.20

TYP.

7.02

TYP.

5.08

TYP.

7.11

TYP.

7.13

TYP.

8.01

132A

A

A

A

A

A

A

A

AA

AA

AA

A

A

A

A

A AA

A

AA

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

131A

TYP.

7.06

8.1

EH-2

EH-2

EH-2

EH-2

EH-2

EH-3

EH-3 EH-2

15.04

TYP.

15.01

FIRST FLOOR

102100

SECOND FLOOR

105960

BOTTOM OF BLDG.

100844

THIRD FLOOR

109820

BOTTOM CHORD OF

TRUSS

113430

GRADE

99844

A-303

1234567

TYP.

8.02

133A

AAAAAAA AAAAAA

A A

A A A A

A A A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

A

EH-2

EH-2

EH-2

EH-2

EH-2

EH-2

15.04

TYP.

15.01 KEYED NOTES:

79MM CORRUGATED METAL SHEATHING. GRAY AS PER COLOR SCHEDULE.

OPEN METAL GRATE WITH SERRATED SURFACE FOR THE EXTERIOR LANDINGS AND

STAIR TREADS.

GALVANIZED STEEL FENCE LOCATED AROUND THE PERIMETER OF THE BUILDING. THE

PANELS OF THE STEEL FENCE WILL BE ANCHORED TO THE PIERS AND THE UNDER SIDE

OF THE BUILDING. BOTTOM OF PANELS WILL FOLLOW GRADE.

900MM X 900MM, LOCKABLE STEEL GATE. THE GATE WILL HAVE THE SAME MATERIAL

CONSTRUCTION AS THE ADJACENT STEEL FENCE. THE FENCE WILL HAVE TWO SINGLE

ACTION HINGES THAT SWING OUT. (NOT YET SHOWN).

200MM METAL INSULATED WALL/SOFFIT PANEL WITH INTERLOCKING EDGES. PANEL

EDGE TO HAVE INDEXED SLOTS WITH CAST-IN ECCENTRIC LOCKS THAT FASTEN

ADJACENT PANELS. BLUE AS PER COLOR SCHEDULE.

PRE FORMED METAL TRIM. COLOR TO MATCH ADJACENT BLUE PANEL.

METAL FLASHING TO SERVE BOTH AS FASCIA AND SOFFIT.

8MM DECORATIVE CORRUGATED METAL PANELING. WEHITE AS PER COLOR SCHEDULE.

OPERABLE CASEMENT WINDOW WITH INSULATED GLAZING.

INSULATED METAL EXTERIOR DOOR.

DOCK BUMPER AT EACH CARGO DOOR.

ARCTIC DRYER AND RANGE EXHAUST VENTS.

ARCTIC AIR HANDLING UNIT EXHAUST HOOD. REF. DETAIL 3/A-515.

ARCTIC INTAKE HOOD. REF. DETAIL 2/A-515.

VENT THROUGH ROOF.

5.08

5.11

5.20

5.21

7.02

7.06

7.11

7.13

8.01

8.02

15.02

15.03

15.04

15.01

GENERAL ELEVATION NOTES:

1. REF. SHEET G-002 FOR SYMBOLS AND ABBREVIATIONS.

2. REF. SHEETS A-601 & A-602 FOR DOOR SCHEDULE, ELEVATIONS AND DETAILS.

3. REF. SHEET A-603 FOR WINDOW ELEVATION AND DETAILS.

11.13

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

D

AT

E:

SC

A L

E:

D R

A W

IN

G C

O D

E :

D

ES

IG

N

ED

BY

D R

A W N

BY

C H

E C

KE

D

BY

IS

S U

E D

AT

E:

D

AT

E:

EN

G

IN

EE

R

/A R

C H

IT

EC

T N

AM

E

PR

O

JE

C

T

EN

G

IN

EE

R

/A R

C H

IT

EC

T

U .S

.A R

M Y

EN

G

IN

EE

R D

IS

TR

IC

T

C O

R

PS

O F

EN

G

IN

EE

R S

N

EW

YO

R

K D

IS

TR

IC

T, N Y

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH: C:\Documents and Settings\E3ENDNMW\My Documents\ARCH_FY12_Thule_Dorm_V7_Central_File_Modular_E3ENDNMW.rvt

1/19/2012 6:03:58 PM

A-202

D es ig ne r Au th or

C h e ck er

FY

D

O R

M

IT

O R

Y, T

H U

LE

A

FB

, G

R

EE

N

LA

N D

EX

TE

R

IO

R

EL

EV

AT

IO

N

S

0 5,000MM 10,000MM

SCALE 1:100 (MILLIMETERS)

1 : 100A-202A-101A

NORTH PART A1

1 : 100A-202A-201

NORTH PART B2

M

AT

C H

LI

N

E

SE

E 2/

A-

M

AT

C H

LI

N

E

SE

E 1/

A-

AM

EN

D

M

EN

T

J

A N

Ja

SECOND FLOOR

105960

BOTTOM OF BLDG.

100844

THIRD FLOOR

109820

BOTTOM CHORD OF

TRUSS

113430

GRADE

99844

A-301

A-304

10 11 12 13 14 15 16 17

TYP.

5.20

TYP.

7.06

A A A A A A A A A A A A

AAAAAAAAAAAA

A A A A A A A A A A A A

TYP.

15.03

TYP.

15.01

TYP.

15.01

EH-3

EH-3

EH-3

EH-3

EH-3

EH-3

FIRST FLOOR

102100

SECOND FLOOR

105960

BOTTOM OF BLDG.

100844

THIRD FLOOR

109820

BOTTOM CHORD OF

TRUSS

113430

GRADE

99844

A-302

A-303

1 2 3 4 5 6 7 8 9

A A A A A A A A A A A A

AAAAAAAAAAAA

A A A A A A A A A A A A

TYP.

5.20

TYP.

7.02

TYP.

5.11

TYP.

7.06

TYP.

5.08

TYP.

7.11

TYP.

7.13

TYP.

8.01

TYP.

15.02

TYP.

15.03

TYP.

15.01

EH-2

EH-2EH-3 EH-3

EH-3 EH-2 EH-3 EH-2

EH-2

EH-2

EH-1

EH-1

EH-1

TYP.

15.04

EH-2

EH-2

EH-2

EH-3

EH-3

EH-3

A-515

TYP.

KEYED NOTES:

79MM CORRUGATED METAL SHEATHING. GRAY AS PER COLOR SCHEDULE.

OPEN METAL GRATE WITH SERRATED SURFACE FOR THE EXTERIOR LANDINGS AND

STAIR TREADS.

GALVANIZED STEEL FENCE LOCATED AROUND THE PERIMETER OF THE BUILDING. THE

PANELS OF THE STEEL FENCE WILL BE ANCHORED TO THE PIERS AND THE UNDER SIDE

OF THE BUILDING. BOTTOM OF PANELS WILL FOLLOW GRADE.

900MM X 900MM, LOCKABLE STEEL GATE. THE GATE WILL HAVE THE SAME MATERIAL

CONSTRUCTION AS THE ADJACENT STEEL FENCE. THE FENCE WILL HAVE TWO SINGLE

ACTION HINGES THAT SWING OUT. (NOT YET SHOWN).

200MM METAL INSULATED WALL/SOFFIT PANEL WITH INTERLOCKING EDGES. PANEL

EDGE TO HAVE INDEXED SLOTS WITH CAST-IN ECCENTRIC LOCKS THAT FASTEN

ADJACENT PANELS. BLUE AS PER COLOR SCHEDULE.

PRE FORMED METAL TRIM. COLOR TO MATCH ADJACENT BLUE PANEL.

METAL FLASHING TO SERVE BOTH AS FASCIA AND SOFFIT.

8MM DECORATIVE CORRUGATED METAL PANELING. WEHITE AS PER COLOR SCHEDULE.

OPERABLE CASEMENT WINDOW WITH INSULATED GLAZING.

INSULATED METAL EXTERIOR DOOR.

DOCK BUMPER AT EACH CARGO DOOR.

ARCTIC DRYER AND RANGE EXHAUST VENTS.

ARCTIC AIR HANDLING UNIT EXHAUST HOOD. REF. DETAIL 3/A-515.

ARCTIC INTAKE HOOD. REF. DETAIL 2/A-515.

VENT THROUGH ROOF.

5.08

5.11

5.20

5.21

7.02

7.06

7.11

7.13

8.01

8.02

15.02

15.03

15.04

15.01

GENERAL ELEVATION NOTES:

1. REF. SHEET G-002 FOR SYMBOLS AND ABBREVIATIONS.

2. REF. SHEETS A-601 & A-602 FOR DOOR SCHEDULE, ELEVATIONS AND DETAILS.

3. REF. SHEET A-603 FOR WINDOW ELEVATION AND DETAILS.

11.13

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

D

AT

E:

SC

A L

E:

D R

A W

IN

G C

O D

E :

D

ES

IG

N

ED

BY

D R

A W N

BY

C H

E C

KE

D

BY

IS

S U

E D

AT

E:

D

AT

E:

EN

G

IN

EE

R

/A R

C H

IT

EC

T N

AM

E

PR

O

JE

C

T

EN

G

IN

EE

R

/A R

C H

IT

EC

T

U .S

.A R

M Y

EN

G

IN

EE

R D

IS

TR

IC

T

C O

R

PS

O F

EN

G

IN

EE

R S

N

EW

YO

R

K D

IS

TR

IC

T, N Y

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH: C:\Documents and Settings\E3ENDNMW\My Documents\ARCH_FY12_Thule_Dorm_V7_Central_File_Modular_E3ENDNMW.rvt

1/19/2012 6:04:03 PM

A-203

D es ig ne r Au th or

C h e ck er

FY

D

O R

M

IT

O R

Y, T

H U

LE

A

FB

, G

R

EE

N

LA

N D

EX

TE

R

IO

R

EL

EV

AT

IO

N

S

0 5,000MM 10,000MM

SCALE 1:100 (MILLIMETERS)

1 : 100A-203A-101A

SOUTH PART B2

1 : 100A-203A-101B

SOUTH PART A1

M

AT

C H

LI

N

E

SE

E 1/

A-

M

AT

C H

LI

N

E

SE

E 2/

A-

AM

EN

D

M

EN

T

J

A N

Ja

SECOND FLOOR

105960

BOTTOM OF BLDG.

100844

THIRD FLOOR

109820

BOTTOM CHORD OF

TRUSS

113430

GRADE

99844

A-304

F E D.1 D C.1 C B A.1 A

A-305

10035

TYP.

7.02

TYP.

5.08

TYP.

5.24

TYP.

5.20

A

A

A

B.1

15.04

TYP.

5.21

FIRST FLOOR

102100

SECOND FLOOR

105960

BOTTOM OF BLDG.

100844

THIRD FLOOR

109820

BOTTOM CHORD OF

TRUSS

113430

GRADE

99844

A-304

FED.1DC.1CBA.1A

A-305

TYP.

8.02

127A

TYP.

7.02

TYP.

5.20

TYP.

5.08

B.1

221A

323A

121A

TYP.

5.21

TYP.

11.13

KEYED NOTES:

79MM CORRUGATED METAL SHEATHING. GRAY AS PER COLOR SCHEDULE.

OPEN METAL GRATE WITH SERRATED SURFACE FOR THE EXTERIOR LANDINGS AND

STAIR TREADS.

GALVANIZED STEEL FENCE LOCATED AROUND THE PERIMETER OF THE BUILDING. THE

PANELS OF THE STEEL FENCE WILL BE ANCHORED TO THE PIERS AND THE UNDER SIDE

OF THE BUILDING. BOTTOM OF PANELS WILL FOLLOW GRADE.

900MM X 900MM, LOCKABLE STEEL GATE. THE GATE WILL HAVE THE SAME MATERIAL

CONSTRUCTION AS THE ADJACENT STEEL FENCE. THE FENCE WILL HAVE TWO SINGLE

ACTION HINGES THAT SWING OUT. (NOT YET SHOWN).

200MM METAL INSULATED WALL/SOFFIT PANEL WITH INTERLOCKING EDGES. PANEL

EDGE TO HAVE INDEXED SLOTS WITH CAST-IN ECCENTRIC LOCKS THAT FASTEN

ADJACENT PANELS. BLUE AS PER COLOR SCHEDULE.

PRE FORMED METAL TRIM. COLOR TO MATCH ADJACENT BLUE PANEL.

METAL FLASHING TO SERVE BOTH AS FASCIA AND SOFFIT.

8MM DECORATIVE CORRUGATED METAL PANELING. WEHITE AS PER COLOR SCHEDULE.

OPERABLE CASEMENT WINDOW WITH INSULATED GLAZING.

INSULATED METAL EXTERIOR DOOR.

DOCK BUMPER AT EACH CARGO DOOR.

ARCTIC DRYER AND RANGE EXHAUST VENTS.

ARCTIC AIR HANDLING UNIT EXHAUST HOOD. REF. DETAIL 3/A-515.

ARCTIC INTAKE HOOD. REF. DETAIL 2/A-515.

VENT THROUGH ROOF.

5.08

5.11

5.20

5.21

7.02

7.06

7.11

7.13

8.01

8.02

15.02

15.03

15.04

15.01

GENERAL ELEVATION NOTES:

1. REF. SHEET G-002 FOR SYMBOLS AND ABBREVIATIONS.

2. REF. SHEETS A-601 & A-602 FOR DOOR SCHEDULE, ELEVATIONS AND DETAILS.

3. REF. SHEET A-603 FOR WINDOW ELEVATION AND DETAILS.

11.13

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

D

AT

E:

SC

A L

E:

D R

A W

IN

G C

O D

E :

D

ES

IG

N

ED

BY

D R

A W N

BY

C H

E C

KE

D

BY

IS

S U

E D

AT

E:

D

AT

E:

EN

G

IN

EE

R

/A R

C H

IT

EC

T N

AM

E

PR

O

JE

C

T

EN

G

IN

EE

R

/A R

C H

IT

EC

T

U .S

.A R

M Y

EN

G

IN

EE

R D

IS

TR

IC

T

C O

R

PS

O F

EN

G

IN

EE

R S

N

EW

YO

R

K D

IS

TR

IC

T, N Y

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH: C:\Documents and Settings\E3ENDNMW\My Documents\ARCH_FY12_Thule_Dorm_V7_Central_File_Modular_E3ENDNMW.rvt

1/19/2012 6:04:11 PM

A-204

D es ig ne r Au th or

C h e ck er

FY

D

O R

M

IT

O R

Y, T

H U

LE

A

FB

, G

R

EE

N

LA

N D

EX

TE

R

IO

R

EL

EV

AT

IO

N

S

1 : 100A-204A-101B

EAST1

1 : 100A-204A-101A

WEST2

0 5,000MM 10,000MM

SCALE 1:100 (MILLIMETERS)

AM

EN

D

M

EN

T

J

A N

Ja

1. HOOD TO BE CONSTRUCTED OF 16 GA. SHT. MTL. W/ 30MM x 30MM L STIFFENERS.

2. ALL CONNECTIONS TO BE COATED W/ MASTIC IN FIELD.

3. HOOD TO BE ASSEMBLED W/ STANDARD SELF-TAPPING SCREWS.

4. BAFFLES INSIDE HOOD TO BE CONSTRUCTED OF 16 GA. SHT. MTL. W/ L STIFFENERS.

5. FRAME TO SUPPORT HOOD: HORIZ. 150MM X 150MM X 6MM, VERT. 150MM X 150MM X 6MM

6. HOOD SHALL BE PROPERLY FASTENED TO SUPPORT FRAME TO ACCOMMODATE ALL

AND ADEQUATE STRENGTH

7. HOOD SHALL BE PROPERLY FABRICATED WITH FRAME MEMBERS FOR PROPER

WIND AND GRAVITY LOADS.

GENERAL NOTES:

W/ MASTIC IN FIELD.

3. ALL CONNECTIONS TO BE COATED

STANDARD SELF-TAPPING SCREWS.

2. HOOD TO BE ASSEMBLED W/

75MM X 75MM X 12MM L STIFFENERS.

16 GA. SHT. MTL. W/

1. HOOD TO BE CONSTRUCTED OF

NOTES ON HOOD:

NOT TO SCALE

MOUNTING DETAIL DIAGRAM

SECTIONPLAN

EH-1

DETAIL.SEE.DET.

EXT.WALL, FOR MTD'G

TO BE MOUNTED ON

SCREEN

BIRD

OPNG.

DUCT

HORIZ. 75X75X6 L

WELDED TO

VERTICAL

FACE OF WALL PNL.

HOOD

HOOD

HORIZ-L

VERT-L

75X 75 X 6

HORIZ. L

R .O

30°

R.O.

150MM METAL FLOOR DECK. RE: STRUCTURAL.5.02

STEEL BEAM. RE: STRUCTURAL.5.06

STEEL CHANNEL. RE: STRUCTURAL.5.23

50MM RIGID MINERAL FIBER FLOOR INSULATION7.03

7.06 PRE FORMED METAL TRIM. COLOR TO MATCH ADJACENT PANEL.

SPRAY FOAM INSULATION7.07

7.12 FIRE STOPPING

FASTENED TO AND ALL EDGES TO HAVE CONTINUOUS BEAD OF SEALANT.

INSULATED PANELS AT ALL JOINTS AND BREAKS. FLASHING TO BE MECHANICALY

PANELS METAL FLASHING TO RUN CONTINUOUSLY ALONG THE INSIDE FACE OF METAL7.16

(1) LAYER OF 13MM GYPSUM BOARD INSTALLED PERPENDICULAR TO METAL DECK BELOW.9.03

5.05 STEEL COLUMN. RE: STRUCTURAL.

9.02 (1) 19MM GYPSUM BOARD OVER (2) LAYERS OF 13MM GYPSUM BOARD.

9.10 (2) LAYERS OF 13MM GYPSUM BOARD OVER 50MM 'Z' CHANNEL PLACED HORIZONTALLY

@ 400MM O.C. WITH 50MM BATT INSULATION OVER (1) LAYER OF 13MM GYPSUM BOARD

OVER 45MM HAT CHANNEL PLACED VERTICALLY @ 400MM O.C.

5.01 OPEN WEB JOIST. RE: STRUCTURAL

5.03 30MM METAL DECK INSTALLED PERPENDICULAR TO DECK BELOW.

REF. STRUCTURAL.

FLANGE (TYP.)

STEEL SUB-GIRT TO EXTEND BEYOND THE OUTSIDE FACE OF THE COLUMN5.04

7.02 200MM METAL INSULATED WALL/SOFFIT PANEL WITH INTERLOCKING EDGE. PANEL

EDGE TO HAVE INDEXED SLOTS WITH INTERNAL MECHANICAL CAMS THAT FASTEN

ADJACENT PANELS.

DETAIL KEY NOTES:

STEEL ANGLE. RE: STRUCTURAL5.09

7.15 3MM EPDM THERMAL BREAK. WHEN BETWEEN STRUCTURAL STEEL MEMBER AND WALL

PANEL EPDM THERMAL BREAK WILL HAVE EITHER AN APPLIED OR MANUFACTURED

ADHESIVE FACE ON THE STRUCTURAL STEEL SIDE OF THE MEMBRANE.

OF THE 100MM DIA. FIBERGLASS DUCT. POP RIVET MTL PLATE INTO METAL PANEL.

BEYOND THE OPENING ON EACH SIDE. OPENING SHOULD ALLOW FOR PASSAGE

1.5MM THICK STEEL PLATE ON EACH SIDE OF INSULATED METAL PANEL EXTEND 200MM5.32

7.10 SEALANT

15.10 ROUND METAL DUCT.

FIBERGLASS DUCT23.00

FIBERGLASS T-PIPE W/ 100MM NOM. FITTING23.20

23.10 FIBERGLASS PIPE FLANGE FUSED TO FIBERGLASS PIPE.

7.12

5.09

5.06

7.02

7.06

7.07

7.15

7.16

5.01

9.10

5.04 7.15

9.02 7.03 9.03 5.03 5.02

7.02

OUTSIDE

INSIDE

5.05

A .F

.F

EXTINGUISHER

FIRE

115 50

7.12

9.10

23.00 7.02

23.10

7.077.07 7.107.10

5.32

23.20

5.05

E E

EXHAUST AIR STREAM

N O

M

CN

O

M

B

N O

M

A

EH-2

EH-3

A

300MM

100MM

B

300MM

100MM

C

300MM

100MM

D

300MM

150MM

E

500MM

350MM

NOM.

D

NOTES:

1. CONTRACTOR TO CONFIRM THAT A, B, AND C NOM.

DIAMETERS FIT WITHIN ONE ANOTHER.

2. TWO (2) OF THE FIBERGLASS TUBES FROM COMMON

LAUNDRY ON SECOND FLOOR SHALL HAVE 90 DEGREE

ELBOWS TO STAGGER THE AIR EXHAUST.

15.10

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

D

AT

E:

SC

A L

E:

D R

A W

IN

G C

O D

E :

D

ES

IG

N

ED

BY

D R

A W N

BY

C H

E C

KE

D

BY

IS

S U

E D

AT

E:

D

AT

E:

EN

G

IN

EE

R

/A R

C H

IT

EC

T N

AM

E

PR

O

JE

C

T

EN

G

IN

EE

R

/A R

C H

IT

EC

T

U .S

.A R

M Y

EN

G

IN

EE

R D

IS

TR

IC

T

C O

R

PS

O F

EN

G

IN

EE

R S

N

EW

YO

R

K D

IS

TR

IC

T, N Y

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH: C:\Documents and Settings\E3ENDNMW\My Documents\ARCH_FY12_Thule_Dorm_V7_Central_File_Modular_E3ENDNMW.rvt

1/19/2012 6:15:02 PM

A-515

D es ig ne r Au th or

C h e ck er

FY

D

O R

M

IT

O R

Y, T

H U

LE

A

FB

, G

R

EE

N

LA

N D

M

IS

C

EL

LA

N

EO

U

S D

ET

AI

LS

1 : 20A-515

AIR INTAKE HOOD DETAIL (PLAN)2

1 : 20A-515

AIR INTAKE HOOD DETAIL (SECTION)1

NTSA-515

AIR EXHAUST HOOD DETAIL3

NTSA-515

EXTERIOR WALL ISOMETRIC DETAIL4

0 500MM 1,000MM

SCALE 1:10 (MILLIMETERS)

0 1,000MM 2,000MM

SCALE 1:20 (MILLIMETERS)

1 : 10A-515I-404

FIRE EXTINGUISHER CAB. ELEV. & SECT.5

1 : 10A-515A-203

EXHAUST HOOD SECTION7

AM

EN

D

M

EN

T

J

A N

Ja

CL

LC

7.21

7.06

TYP.

7.10

7.02

7.16

TYP.

TYP.

7.07

7.10

TYP.

7.23

5.05

51550

TYP.

TY

P.

LC

LC

7.02

7.10

TYP.

7.06

7.21

TYP.

7.10

7.07

TYP.

TYP.

7.16

7.23

7.02

7.10

TYP.

7.06

7.21

5.05

50 315

BL

DG

AB

OV

E

TYP.

TY

P.

A-518 A-518

LC

T/PIER

7.02

7.07

7.06

7.21

3.01

7.10

TYP.

5.05

7.06

7.23

7.16

7.28

0 M

IN

0 M

IN

0 T

YP

A-518 A-518

T/PIER

CL

7.16

7.23

7.06

5.05

TYP.

7.10

3.01

7.21

7.06

7.07

7.02

7.16

7.10

7.07

7.06

7.21

7.02

7.28

0 T

YP

0 M

IN

0 M

IN

20050

SEE PLAN

3.01 PRECAST CONCRETE PIER. RE: TO STRUCTURAL

5.05 STEEL COLUMN. RE: STRUCTURAL.

7.06 PRE FORMED METAL TRIM. COLOR TO MATCH ADJACENT PANEL.

SPRAY FOAM INSULATION7.07

AND ALL EDGES TO HAVE CONTINUOUS BEAD OF SEALANT.

PANELS AT ALL JOINTS AND BREAKS. FLASHING TO BE MECHANICALY FASTENED TO PANELS

METAL FLASHING TO RUN CONTINUOUSLY ALONG THE INSIDE FACE OF METAL INSULATED7.16

SURFACES.

GRADE. RIGID INSULATION TO BE WRAPPED WITH PRE-FINISHED METAL TO MATCH ADJACENT

50MM RIGID INSULATION LOCATED AT CONC. PIERS TO EXTEND A MIN. OF 200MM BELOW7.21

7.10 SEALANT

THE FOUNDATION PIER AND BELOW THE INSULATED METAL PANELS.

COLUMN AND ADJACENT INSULATED METAL PANEL. INSULATION TO FILL ALL AIR SPACE ABOVE MINERAL FIBER INSULATION TO FILL FLANGE OF COLUMN AS WELL AS ANY GAPS BETWEEN THE7.23

15.06 RADIATOR SUPPLY AND RETURN CHASE. OCCURS AT FIRST FLOOR ONLY.

REFER TO MECHANICAL DRAWINGS.

WALL MOUNTED RADIATOR. REFER TO MECHANICAL DRAWINGS FOR SIZE.15.05

7.02 200MM METAL INSULATED WALL / SOFFIT PANEL WITH INTERLOCKING EDGE. PANEL EDGE TO

HAVE INDEXED SLOTS WITH CAST-IN ECCENTRIC LOCKS THAT FASTEN ADJECENT PANELS.

DETAIL KEY NOTES:

7.28 10MM NEOPRENE THERMAL BREAK. RE: STRUCTURAL

CHASE NOT

SHOWN FOR

CLARITY

ELEVATION

PLAN

15.0615.05

RETURN

SUPPLY

RE

TU

RN

SU

PP

LY

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

D

AT

E:

SC

A L

E:

D R

A W

IN

G C

O D

E :

D

ES

IG

N

ED

BY

D R

A W N

BY

C H

E C

KE

D

BY

IS

S U

E D

AT

E:

D

AT

E:

EN

G

IN

EE

R

/A R

C H

IT

EC

T N

AM

E

PR

O

JE

C

T

EN

G

IN

EE

R

/A R

C H

IT

EC

T

U .S

.A R

M Y

EN

G

IN

EE

R D

IS

TR

IC

T

C O

R

PS

O F

EN

G

IN

EE

R S

N

EW

YO

R

K D

IS

TR

IC

T, N Y

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH: C:\Documents and Settings\E3ENDNMW\My Documents\ARCH_FY12_Thule_Dorm_V7_Central_File_Modular_E3ENDNMW.rvt

1/19/2012 6:04:15 PM

A-518

D es ig ne r Au th or

C h e ck er

FY

D

O R

M

IT

O R

Y, T

H U

LE

A

FB

, G

R

EE

N

LA

N D

FO

U

N D

AT

IO

N

IN

SU

LA

TI

O

N D

ET

AI

LS

R

AD

IA

TO

R C

H

AS

E D

ET

AI

LS

1 : 10A-518

INTERIOR COL. FOUNDATION INSULATION (PLAN)1

1 : 10A-518

PERIMETER COL. FOUNDATION INSULATION (PLAN)2

1 : 10A-518

INTERIOR COL. FOUNDATION INSULATION (SECTION)4

1 : 10A-518

PERIMETER COL. FOUNDATION INSULATION (SECTION)5

1 : 5A-518

TYPICAL FIRST FLOOR RADIATOR CHASE DETAIL3

0 250MM 500MM

SCALE 1:5 (MILLIMETERS)

0 500MM 1,000MM

SCALE 1:10 (MILLIMETERS)

3 3

AM

EN

D

M

EN

T

J

A N

Ja

M

AT

C H

LI

N

E

SE

E I-4

-2

EQEQ

EQ EQ

EQEQ

EQ EQ9.19

16.04

10.15

M

AT

C H

LI

N

E

SE

E I-4

-1

EQEQ EQ EQ

EQEQ9.19

16.04

TYP.

I-404 A-515

M

AT

C H

LI

N

E

SE

E I-4

-4

EQ EQEQ EQ EQEQ

9.19

16.04

M

AT

C H

LI

N

E

SE

E I-4

-3

EQ EQ

EQ EQEQEQ

EQEQ

9.19

16.04

10.15

9.19

10.15

TYP.

I-404 A-515

9.19 10.15

9.19

10.15

9.19

10.15

INTERIOR GENERAL NOTES:

1. REFER TO ARCHITECTURAL DRAWINGS FOR ELEVATION

LOCATIONS

2. ALL DIMENSIONS ARE FROM FINISHED FLOOR (F.F.)

3. REFER TO CID PACKAGE UNDER SEPARATE COVER FOR

ADDITIONAL INFORMATION PERTAINING TO FIXTURES,

FINISHES, AND FURNISHINGS.

KEY NOTES:

RUBBER BASE. REF. CID PACKAGE UNDER

SEPARATE COVER.

CLEAR ACRYLIC CORNER GUARD. 1220MM FROM

TOP OF BASE. REF. CID PACKAGE UNDER

SEPARATE COVER.

WALL SCONCE. REF. CID PACKAGE UNDER

SEPARATE COVER.

PAPER TOWEL AND WASTE RECEPTACLE

9.19

10.15

16.04

21.12

21.12

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

D

AT

E:

SC

A L

E:

D R

A W

IN

G C

O D

E :

D

ES

IG

N

ED

BY

D R

A W N

BY

C H

E C

KE

D

BY

IS

S U

E D

AT

E:

D

AT

E:

EN

G

IN

EE

R

/A R

C H

IT

EC

T N

AM

E

PR

O

JE

C

T

EN

G

IN

EE

R

/A R

C H

IT

EC

T

U .S

.A R

M Y

EN

G

IN

EE

R D

IS

TR

IC

T

C O

R

PS

O F

EN

G

IN

EE

R S

N

EW

YO

R

K D

IS

TR

IC

T, N Y

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH: C:\Documents and Settings\E3ENDNMW\My Documents\ARCH_FY12_Thule_Dorm_V7_Central_File_Modular_E3ENDNMW.rvt

1/24/2012 12:09:09 PM

I-404

D es ig ne r Au th or

C h e ck er

FY

D

O R

M

IT

O R

Y, T

H U

LE

A

FB

, G

R

EE

N

LA

N D

IN

TE

R

IO

R

EL

EV

AT

IO

N

S

1 : 50I-404A-101A

FIRST AND SECOND FLOOR CORRIDOR ELEVATION1

1 : 50I-404A-101B

FIRST AND SECOND FLOOR CORRIDOR ELEVATION2

1 : 50I-404A-101B

FIRST AND SECOND FLOOR CORRIDOR ELEVATION3

1 : 50I-404A-101A

FIRST AND SECOND FLOOR CORRIDOR ELEVATION4

1 : 50I-404A-101B

FIRST FLOOR LOBBY ELEVATION5

1 : 50I-404A-403

FIRST FLOOR LOBBY ELEVATION6

1 : 50I-404A-101B

FIRST FLOOR LOBBY ELEVATION7

1 : 50I-404A-403

FIRST FLOOR LOBBY ELEVATION8

0 1,250MM 2,500MM

SCALE 1:50 (MILLIMETERS)

1 : 50I-404A-102A

COMMON BATH ELEVATION9

AM

EN

D

M

EN

T

J

A N

Ja

S

L

UC

FS

MU

HPS

HPC

GWS

GWR

TC

RM

RPM

SA

SP

SPECS

SQ

STRUC

SV

SAD

TEMP

THERM

T

TYP

UH

VD

VEL

VERT

VFD

VOL

W

W/

WB

WG

W/O

TC

ROOM

REVOLUTIONS PER MINUTE

RISE IN DUCTWORK

SUPPLY AIR

STATIC PRESSURE

SPECIFICATIONS

SQUARE

STRAINER WITH VALVED

AND CAPPED BLOW DOWN

STRUCTURAL

SOLENOID VALVE

SUPPLY AIR DIFFUSER

TEE UP (PIPE OR SINGLE

LINE ROUND DUCT)

TEE DOWN (PIPE OR

SINGLE LINE ROUND DUCT)

TEMPERATURE

PIPING SYSTEM

THERMOMETER

IN THERMOWELL

TEMPERATURE SENSOR

AND TRANSMITTOR

TURNING VANES

TYPICAL

UNIT HEATER

UNION

VOLUME DAMPER

VELOCITY

VERTICAL

VARIABLE FREQUENCY DRIVE

VOLUME

WIDE

WITH

WET BULB

WATER GAUGE

WITHOUT

TIME CLOCK

TEMPERATURE CONTROL

LWT

MAX

MECH

MER

MFGR, MFR

MIN

MISC

MD

MU

N.C.

NIC

NO.

N.O.

NTS

OA

OD

P

PC

PD

PH

PLBG

PRESS

RA

RAD

RAR

RLF

REQ'D

RH

RHCLEAVING WATER

TEMPERATURE

MAXIMUM

MECHANICAL

MECHANICAL EQUIPMENT

ROOM

MANUFACTURER

MINIMUM

MISCELLANEOUS

MOTORIZED SHUT-OFF DAMPER

MAKE-UP WATER

NORMALLY CLOSED

NOT IN CONTRACT

NUMBER

NORMALLY OPEN

NOT TO SCALE

OUTSIDE AIR

OUTSIDE DIAMETER

PUMP

PLUMBING CONTRACTOR

PRESSURE DROP

PHASE

PLUMBING

PLUG VALVE

PRESSURE

PRESSURE GAGE

W/PET COCK

HYDRONIC PIPING SYSTEM

RETURN AIR

RADIATOR

RETURN AIR REGISTER

RELIEF

REQUIRED

REDUCER

RELATIVE HUMIDITY

REHEAT COIL

FIN FLR

FT

FS

GA

GC

GWR

GWS

HPC

HPS

HTG

HTR

HVAC

HWP

HWR

HWS

ID

INSUL

ISP

KW

L

LAT

FINISHED FLOOR

FIN TUBE

FLANGED CONNECTION

FLEXIBLE PIPING

CONNECTION

FLOW SWITCH

GAUGE

GENERAL CONTRACTOR

GLOBE VALVE

GATE VALVE

GLYCOL WATER HEATING

RETURN

GLYCOL WATER HEATING

SUPPLY

HIGH PRESSURE

CONDENSATE

HIGH PRESSURE STEAM

HEATING

HEATER

HEATING VENTILATION/

AIR CONDITIONING

HOT WATER PUMP

HOT WATER RETURN

HOT WATER SUPPLY

INSIDE DIAMETER

INSULATE(D), INSULATION

INTERNAL STATIC PRESSURE

KILOWATT

LONG

LEAVING AIR TEMPERATURE

CW

DB

DDC

DDCP

DEG

DIA

DISC

DN

DSD

DWG

EA

EAT

EC

EF

ELEC

ESP

ET

EWT

EXH

EXIST

COLD WATER

DRY BULB

DIRECT DIGITAL

CONTROL

DIRECT DIGITAL

CONTROL PANEL

DEGREE(S)

DIAMETER

DIRECTION OF FLOW

DISCONNECT

DOOR LOUVER

DOOR UNDERCUT

DOWN

DUCT SMOKE DETECTOR

DRAWING

DROP IN DUCTWORK

DUCT DIMENSIONS -

SIDE SHOWN

X SIDE NOT SHOWN

DUCTWORK SUPPLY DOWN

DUCTWORK SUPPLY UP

DUCTWORK EXHAUST

OR RETURN DOWN

DUCTWORK EXHAUST

OR RETURN UP

EXHAUST AIR

ENTERING AIR TEMPERATURE

ELECTRICAL CONTRACTOR

EXHAUST FAN

EXPANDED ENTRY CONN. ON

TOP OF MAIN DUCT W/ELBOW

TO HORIZONTAL

ELBOW DOWN (SINGLE LINE

SQ. OR RECT. DUCT)

ELBOW DOWN (PIPE OR

SINGLE LINE ROUND DUCT)

ELBOW UP (PIPE OR

SINGLE LINE ROUND DUCT)

ELECTRIC(AL)

EXTERNAL STATIC PRESSURE

EXPANSION LOOP

EXPANSION TANK

ENTERING WATER

TEMPERATURE

EXHAUST

EXISTING

FLEXIBLE CONNECTION OR

FLEX CONN

AD

AFF

AFS

APD

APPROX

ARCH

ATC

AS

ASME

AV

MV

BFV

BLDG

BOT

CLG

CONC

CONN

CONT

CONTR

CORR

ACCESS DOOR

ABOVE FINISHED FLOOR

AIRFLOW STATION

AIR PRESSURE DROP

APPROXIMATE

ARCHITECT

AUTOMATIC TEMPERATURE

CONTROL

AIR SEPARATOR

AMERICAN SOCIETY OF

MECHANICAL ENGINEERS

AIR VENT (AUTOMATIC)

AIR VENT (MANUAL)

BALL VALVE

BUTTERFLY VALVE

BUILDING

BOTTOM

CONTROL VALVE, 3 WAY

CONTROL VALVE, 2 WAY

PIPE CAP, OR SINGLE LINE

DUCT CAP

CHECK VALVE (SWING GATE)

CEILING

CONCRETE

CONNECTION

CIRCUIT SETTER

BALANCE VALVE

CONTINUATION

CONTRACTOR

CORRIDOR

DESCRIPTION

T

ABBREVSYMBOL

UP

ABBREV

HWR

SYMBOL

HWS

DESCRIPTIONSYMBOL ABBREVABBREV DESCRIPTION

HVAC ABBREVIATIONS AND LEGEND

DESCRIPTIONDESCRIPTION

DN

SYMBOL

AV

ABBREV

DDCP

AxB

SYMBOL

m, M METERS mm MILLIMETERS

SF SUPPLY FAN

Pa PASCAL

R RADIUS

C CELSIUS

VU VENTILATION UNIT

K KELVIN

SHX STEAM-TO-WATER

HEAT EXCHANGER

LHE LIQUID-TO-LIQUID

HEAT EXCHANGER

W WATT

EXHAUST AIR DEVICE

KPa KILOPASCAL

KG, Kg KILOGRAM

L/S, l/S LITERS PER SECOND

Hz HERTZ

PRESSURE RELIEF VALVE

WS WATER SENSOR

HT HUMIDITY TRANSMITTERHT

FLEX FLEXIBLE

CD MOTORIZED CONTROL DAMPER

(KITCHEN HOOD)

MOTORIZED DAMPER

P PRESSURE SENSORP

FLEX DUCT FLEXIBLE DUCT

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

D

AT

E:

SC

A L

E:

D R

A W

IN

G C

O D

E :

D

ES

IG

N

ED

BY

D R

A W N

BY

C H

E C

KE

D

BY

IS

S U

E D

AT

E:

D

AT

E:

EN

G

IN

EE

R

/A R

C H

IT

EC

T N

AM

E

PR

O

JE

C

T

EN

G

IN

EE

R

/A R

C H

IT

EC

T

U .S

.A R

M Y

EN

G

IN

EE

R D

IS

TR

IC

T

C O

R

PS

O F

EN

G

IN

EE

R S

N

EW

YO

R

K D

IS

TR

IC

T, N Y

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH: C:\Documents and Settings\E3ENDJM3\My Documents\MECH_FY12_THULE_DORM_E3ENDJM3.rvt

1/18/2012 11:15:02 AM

M-001

JM

M

/C S

Au th or C h e ck er

FY

D

O R

M

IT

O R

Y, T

H U

LE

A

FB

, G

R

EE

N

LA

N D

M

EC

H

AN

IC

AL

LE

G

EN

D

R

EV

IS

ED

P

ER

A

M

EN

D M

EN

T

1/

/1

JM

M

Ja

GENERAL NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

ALL SUPPLY DUCTWORK AND ALL RETURN DUCTWORK SHALL BE CONSTRUCTED

FOR 1000 Pa (2" w.c.) PRESSURE CLASS. DUCTWORK SHALL BE SEALED IN

ACCORDANCE WITH REQUIREMENTS INDICATED IN SPECIFICATION SECTION 23 00 00.

ALL DUCTWORK AND HVAC EQUIPMENT SHALL BE INSULATED IN ACCORDANCE WITH

SPECIFICATION SECTION 23 07 00.

ALL DUCT ELBOWS, OFFSETS, ETC. SHALL BE MADE WITH RIGID SHEET METAL DUCT.

FLEXIBLE DUCT RUN OUTS TO AIR DISTRIBUTION DEVICES SHALL BE INSTALLED

ONLY IN VERTICAL POSITION AND SHALL NOT EXCEED 0.914m (3 FT.) IN LENGTH.

UNLESS OTHERWISE NOTED, CONTRACTOR SHALL PROVIDE AIR VOLUME BALANCING

DAMPERS ON ALL SUPPLY AND EXHAUST DUCT RUN OUT CONNECTIONS TO AIR

DISTRIBUTION DEVICES. DAMPERS SHALL BE INSTALLED NEAR BRANCH TAKE-OFF

LOCATIONS.

ALL FLOOR MOUNTED HVAC EQUIPMENT LOCATED IN THE MECHANICAL ROOM

SHALL BE INSTALLED ON AND ANCHORED TO EQUIPMENT BASE MOUNTING

FOOTING. FOOTING SHALL BE PRODUCED BY THE SAME MANUFACTURER AS THE

HVAC EQUIPMENT.

UNLESS OTHERWISE INDICATED, NON-ELECTRIC THERMOSTATIC VALVES WITH

INTEGRAL THERMOSTATIC SENSOR SHALL BE PROVIDED AS PART OF A PACKAGED

INTEGRATED RADIATOR. ALL OTHER ROOM THERMOSTATS NOT LOCATED ON

RADIATORS SHALL BE MOUNTED AT 1372 mm (4'-6") ABOVE THE FINISHED FLOOR.

ALL BASE MOUNTED PUMPS SHALL BE PROVIDED WITH VIBRATION ISOLATION AND

SHALL BE GROUTED IN PLACE ON TOP OF EQUIPMENT PADS.

DUCT AND FITTINGS SHALL BE PROVIDED AND INSTALLED IN ACCORDANCE WITH

SMACNA. HOWEVER, A MINIMUM OF 24 GAUGE SHEET METAL DUCT SHALL BE USED

FOR SUPPLY & RETURN DUCT FROM AHU-1, AHU-2, AND AHU-3 WHEN A THINNER

GAUGE IS SPECIFIED BY SMACNA.

UNLESS OTHERWISE INDICATED, PROVIDE OBD'S FOR AIR DISTRIBUTION DEVICES.

THE OBD'S SHALL BE LEFT IN THE FULL OPEN POSITION. AIR VOLUME BALANCING

DAMPERS SHALL ALSO BE PROVIDED AS INDICATED IN THESE NOTES AND AS

SHOWN ON THE PLANS.

ACCESS PANELS SHALL BE PROVIDE FOR ALL VALVES AND DAMPERS WHERE

ACCESS IS OTHERWISE NOT AVAILABLE.

10.

11.

12.

13.

14.

INSULATE ROOM CLOTHES DRYER AND ALL KITCHEN EXHAUST DUCTS A MINIMUM

DISTANCE OF 3.0m FROM THE PENETRATION OF THE EXERIOR WALL'S INNER SURFACE.

INSULATION TYPE SHALL BE PER UFGS 23 07 00, PARAGRAPH 2.4.1 WITH THICKNESS

PER TABLE 4.

FOR ALL CLOTHES DRYERS LOCATED IN LAUNDRY ROOMS, EXHAUST DUCT SHALL

BE INSULATED IN ANY SPACE OUTSIDE OF THE LAUNDRY ROOM. INSULATION TYPE

SHALL BE PER UFGS 23 07 00, PARAGRAPH 2.4.1 WITH THICKNESS PER TABLE 4.

ALL CLOTHES DRYER AND KITCHEN EXHAUST DUCT SHALL BE GALVANIZED METAL,

ROUND, HARD DUCT; FLEXIBLE AND VINYL DUCT SHALL NOT BE USED. COMPLY

WITH ALL MANUFACTURER'S INSTRUCTIONS. ENSURE ALL CONTECTIONS ARE POSITIVELY

SEALED TO PREVENT AIR LEAKAGE.

PROVIDE ACCESS FOR MAINTENANCE AND INSPECTION AT LOCATION BEFORE

PENETRATION THROUGH EXTERIOR WALL AND AT EVERY 4.5m INTERVALS AND

DUCT WORK SEAM CONNECTIONS. MINIMUM ACCESS DOOR SIZE SHALL BE NO LESS THAN

400mm X 400mm.

KEYED NOTES

1.

2.

3.

4.

5.

6.

7.

AIR HANDLING UNIT WITH GLYCOL WATER HEATING COIL. ROUTE SUPPLY DUCT

TO THE AIR DISTRIBUTION DEVICES AS SHOWN.

DRYER EXHAUST VENT. CONNECT VENT TO ARTIC EXHAUST HOOD. SEE DETAIL

ON SHEET A-515 FOR ACTUAL DIMENSIONS.

KITCHEN RANGE HOOD VENT. CONNECT TO ARTIC EXHAUST HOOD. SEE DETAIL

ON SHEET A-515 FOR ACTUAL DIMENSIONS.

250mm X 250mm RETURN AIR TRANSFER DUCT WITH ACCOUSTICAL LINING. SEE

DETAIL 3 ON SHEET M-503.

FROST PROOF ARCTIC EXHAUST HOOD. SEE DETAIL ON SHEET A-515 FOR ACTUAL

DIMENSIONS.

FROST PROOF ARCTIC INTAKE HOOD. SEE DETAIL ON SHEET A-515 FOR ACTUAL

DIMENSIONS.

SPACE PRESSURE SENSOR/TRANSMITTER. INSTALL WHERE SHOWN. SEE SHEET

M702 FOR ADDITIONAL REQUIREMENTS.

UP

DN

DN

UP

DN

T T

T

T T

P

PART A

UH-4

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

B 9.4 L/s B 9.4 L/s B 9.4 L/s B 9.4 L/s

A 9.4 L/s

A 9.4 L/s

A 9.4 L/s A 9.4 L/s A 9.4 L/s A 9.4 L/s A 9.4 L/s A 9.4 L/s A 24.0 L/s

A 24.0 L/s

A 24.0 L/s

B 80.0 L/s

B 9.4 L/s B 9.4 L/s

B 9.4 L/s

B 9.4 L/s A 9.4 L/s A 9.4 L/s

A 9.4 L/s

A 9.4 L/s A 9.4 L/s A 9.4 L/s

CUH-1

4 4

4 4

3 3

450x300

2 2

AHU-1

175ø

100ø

200ø

350x250

175ø

200ø 200ø

150x150

150x150

C 19.0 L/s

A 9.4 L/s

A 9.4 L/s

100ø

175ø

250ø

400x250 300x150

200ø

200ø

100ø

150x150

175ø175ø

100ø

200ø

150x150

175ø

150ø

150ø

150x150

175ø

150ø

150ø

400x250

150x150

175ø 150ø

150ø

175ø

150x150

150ø

150ø

450x300

150x150

350x200 300x200

150ø 175ø

150ø

150ø

150ø

175ø

150x150 150x150

150ø

150ø

175ø

250ø

250ø

250ø

200ø

200ø

M-101A

M-401

VDVDVD

VD VD

CD

CD

CD

B 59.0 L/s

VD

VD

VD

CD

CD

CD

VD

VD

VD

VD

VD

150x150

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD VD VD

VD

VD

VD

VD VD VD VD

CD

CD VD

CD CD

CD

CD

VD VD

150x150

150x150

VD

VD

MD

UH-4

M-102A

SF-1

450x300 D 59.0 L/s

VD

D 80.0 L/s

FIRST FLOOR

102100

FIRST FLOOR

102100

SECOND FLR

FRAMING

105670

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

D

AT

E:

SC

A L

E:

D R

A W

IN

G C

O D

E :

D

ES

IG

N

ED

BY

D R

A W N

BY

C H

E C

KE

D

BY

IS

S U

E D

AT

E:

D

AT

E:

EN

G

IN

EE

R

/A R

C H

IT

EC

T N

AM

E

PR

O

JE

C

T

EN

G

IN

EE

R

/A R

C H

IT

EC

T

U .S

.A R

M Y

EN

G

IN

EE

R D

IS

TR

IC

T

C O

R

PS

O F

EN

G

IN

EE

R S

N

EW

YO

R

K D

IS

TR

IC

T, N Y

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH: C:\Documents and Settings\E3ENDJM3\My Documents\MECH_FY12_THULE_DORM_E3ENDJM3.rvt

1/18/2012 11:15:10 AM

M-101A

JM

M

/C S

Au th or C h e ck er

FY

D O

R M

IT

O

R Y, TH

U

LE

AF

B, G

R

EE

N

LA

N D

M

EC

H

AN

IC

AL

H

VA

C

FI

R

ST

FL

O

O R

-P

AR

T

PL

AN

A

M

AT

C H

LI

N

E

SE

E

SH

EE

T M

-1

B

FO

R C

O N

TI

N

U

AT

IO

N

1 : 100

MECHANICAL HVAC FIRST FLOOR - PART PLAN A

N

TRUE NORTH

WIND

PLAN NORTH

0 5,000MM 10,000MM

SCALE 1:100 (MILLIMETERS)

1 : 50

First Floor Cooridor Transition

R

EV

IS

ED

PE

R

AM

EN

D

M

EN

T 1/

/1

JM

M

Ja

2.

3.

4.

5.

6.

7.

8.

9.

ALL SUPPLY DUCTWORK AND ALL RETURN DUCTWORK SHALL BE CONSTRUCTED

FOR 1000 Pa (2" w.c.) PRESSURE CLASS. DUCTWORK SHALL BE SEALED IN

ACCORDANCE WITH REQUIREMENTS INDICATED IN SPECIFICATION SECTION 23 00 00.

ALL DUCTWORK AND HVAC EQUIPMENT SHALL BE INSULATED IN ACCORDANCE WITH

SPECIFICATION SECTION 23 07 00.

ALL DUCT ELBOWS, OFFSETS, ETC. SHALL BE MADE WITH RIGID SHEET METAL DUCT.

FLEXIBLE DUCT RUN OUTS TO AIR DISTRIBUTION DEVICES SHALL BE INSTALLED

ONLY IN VERTICAL POSITION AND SHALL NOT EXCEED 0.914m (3 FT.) IN LENGTH.

UNLESS OTHERWISE NOTED, CONTRACTOR SHALL PROVIDE AIR VOLUME BALANCING

DAMPERS ON ALL SUPPLY AND EXHAUST DUCT RUN OUT CONNECTIONS TO AIR

DISTRIBUTION DEVICES. DAMPERS SHALL BE INSTALLED NEAR BRANCH TAKE-OFF

LOCATIONS.

ALL FLOOR MOUNTED HVAC EQUIPMENT LOCATED IN THE MECHANICAL ROOM

SHALL BE INSTALLED ON AND ANCHORED TO EQUIPMENT BASE MOUNTING

FOOTING. FOOTING SHALL BE PRODUCED BY THE SAME MANUFACTURER AS THE

HVAC EQUIPMENT.

UNLESS OTHERWISE INDICATED, NON-ELECTRIC THERMOSTATIC VALVES WITH

INTEGRAL THERMOSTATIC SENSOR SHALL BE PROVIDED AS PART OF A PACKAGED

INTEGRATED RADIATOR. ALL OTHER ROOM THERMOSTATS NOT LOCATED ON

RADIATORS SHALL BE MOUNTED AT 1372 mm (4'-6") ABOVE THE FINISHED FLOOR.

ALL BASE MOUNTED PUMPS SHALL BE PROVIDED WITH VIBRATION ISOLATION AND

SHALL BE GROUTED IN PLACE ON TOP OF EQUIPMENT PADS.

DUCT AND FITTINGS SHALL BE PROVIDED AND INSTALLED IN ACCORDANCE WITH

SMACNA. HOWEVER, A MINIMUM OF 24 GAUGE SHEET METAL DUCT SHALL BE USED

FOR SUPPLY & RETURN DUCT FROM AHU-1, AHU-2, AND AHU-3 WHEN A THINNER

GAUGE IS SPECIFIED BY SMACNA.

UNLESS OTHERWISE INDICATED, PROVIDE OBD'S FOR AIR DISTRIBUTION DEVICES.

THE OBD'S SHALL BE LEFT IN THE FULL OPEN POSITION. AIR VOLUME BALANCING

DAMPERS SHALL ALSO BE PROVIDED AS INDICATED IN THESE NOTES AND AS

SHOWN ON THE PLANS.

ACCESS PANELS SHALL BE PROVIDE FOR ALL VALVES AND DAMPERS WHERE

ACCESS IS OTHERWISE NOT AVAILABLE.

10.

11.

12.

13.

14.

INSULATE ROOM CLOTHES DRYER AND ALL KITCHEN EXHAUST DUCTS A MINIMUM

DISTANCE OF 3.0m FROM THE PENETRATION OF THE EXERIOR WALL'S INNER SURFACE.

INSULATION TYPE SHALL BE PER UFGS 23 07 00, PARAGRAPH 2.4.1 WITH THICKNESS

PER TABLE 4.

FOR ALL CLOTHES DRYERS LOCATED IN LAUNDRY ROOMS, EXHAUST DUCT SHALL

BE INSULATED IN ANY SPACE OUTSIDE OF THE LAUNDRY ROOM. INSULATION TYPE

SHALL BE PER UFGS 23 07 00, PARAGRAPH 2.4.1 WITH THICKNESS PER TABLE 4.

ALL CLOTHES DRYER AND KITCHEN EXHAUST DUCT SHALL BE GALVANIZED METAL,

ROUND, HARD DUCT; FLEXIBLE AND VINYL DUCT SHALL NOT BE USED. COMPLY

WITH ALL MANUFACTURER'S INSTRUCTIONS. ENSURE ALL CONTECTIONS ARE POSITIVELY

SEALED TO PREVENT AIR LEAKAGE.

PROVIDE ACCESS FOR MAINTENANCE AND INSPECTION AT LOCATION BEFORE

PENETRATION THROUGH EXTERIOR WALL AND AT EVERY 4.5m INTERVALS AND

DUCT WORK SEAM CONNECTIONS. MINIMUM ACCESS DOOR SIZE SHALL BE NO LESS THAN

400mm X 400mm.

KEYED NOTES

1.

2.

250mm X 250mm RETURN AIR TRANSFER DUCT WITH ACCOUSTICAL LINING. SEE DETAIL 3

ON SHEET M-503.

KITCHEN RANGE HOOD VENT. CONNECT VENT TO ARTIC EXHAUST HOOD. SEE DETAIL ON

SHEET A-515 FOR ACTUAL DIMENSIONS.

DN

UP

F

D W

F

D W

F

D W

F

D W

F

D W

F

D W

T

PART B

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s C 19.0 L/s

C 19.0 L/s C 19.0 L/s

C 19.0 L/s C 19.0 L/s

C 19.0 L/s C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

A 9.4 L/s A 9.4 L/s A 9.4 L/s

A 9.4 L/s A 9.4 L/s

A 9.4 L/s

A 9.4 L/sA 9.4 L/s

A 9.4 L/s A 9.4 L/s A 9.4 L/s A 9.4 L/s

A 9.4 L/s A 9.4 L/s

A 9.4 L/s

A 9.4 L/s A 9.4 L/s

A 9.4 L/s

A 9.4 L/s

A 9.4 L/s A 9.4 L/s

A 9.4 L/s

A 9.4 L/s

A 9.4 L/s A 9.4 L/s A 9.4 L/s A 9.4 L/s A 9.4 L/s A 9.4 L/s

A 9.4 L/s

CUH-1

1 1

1 1 1

1 1

A 59.0 L/s

150ø

150ø

150x150

400x250 350x250

150ø

150ø

150ø

150ø

150ø 150ø

175ø

150ø

150ø 150ø 150ø 150ø

150x150

175ø

150x150 150x150

150ø

175ø

150ø 150ø

150ø

250x150

150x150 150x150

200x200 300x200D 115.0 L/s

175ø

150ø

200ø

150ø 150ø

150ø 150ø

150ø

150ø

150ø 150ø

175ø

150ø

150ø

150ø

150x150

250x150 150x150

250x250 250x200 150x150

150x150

150ø

175ø

150ø

200ø

VD

VD

VD VD

VDVD

VD

VD

VD VD

VD VD

VDVD

VDVD

VD

VD

VD VD

VDVD

VD

VD

VD VD

VD

VD

VD

VD

VD

VD

VD

CD

CD

CD

CD

CD

CD

VD VD

VD VD

VDVD

150x150 150x150

UH-4

UH-3

RAD-1

M-101B

2 2

2 2

FIRST FLOOR

102100

SECOND FLR

FRAMING

105670

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

D

AT

E:

SC

A L

E:

D R

A W

IN

G C

O D

E :

D

ES

IG

N

ED

BY

D R

A W N

BY

C H

E C

KE

D

BY

IS

S U

E D

AT

E:

D

AT

E:

EN

G

IN

EE

R

/A R

C H

IT

EC

T N

AM

E

PR

O

JE

C

T

EN

G

IN

EE

R

/A R

C H

IT

EC

T

U .S

.A R

M Y

EN

G

IN

EE

R D

IS

TR

IC

T

C O

R

PS

O F

EN

G

IN

EE

R S

N

EW

YO

R

K D

IS

TR

IC

T, N Y

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH: C:\Documents and Settings\E3ENDJM3\My Documents\MECH_FY12_THULE_DORM_E3ENDJM3.rvt

1/18/2012 11:15:15 AM

M-101B

JM

M

/C S

Au th or C h e ck er

FY

D O

R M

IT

O

R Y, TH

U

LE

AF

B, G

R

EE

N

LA

N D

M

EC

H

AN

IC

AL

H

VA

C

FI

R

ST

FL

O

O R

-P

AR

T

PL

AN

B

M

AT

C H

LI

N

E

- S

EE

S

H

EE

T M

-1

A

FO

R C

O N

TI

N

U

AT

IO

N

1 : 100

MECHANICAL HVAC FIRST FLOOR - PART PLAN B

N

TRUE NORTH

WIND

PLAN NORTH

0 5,000MM 10,000MM

SCALE 1:100 (MILLIMETERS) 1 : 50

COORIDOR SECTION VIEW

R

EV

IS

ED

PE

R

AM

EN

D

M

EN

T 1/

/1

JM

M

Ja

2.

3.

4.

5.

6.

7.

8.

9.

ALL SUPPLY DUCTWORK AND ALL RETURN DUCTWORK SHALL BE CONSTRUCTED

FOR 1000 Pa (2" w.c.) PRESSURE CLASS. DUCTWORK SHALL BE SEALED IN

ACCORDANCE WITH REQUIREMENTS INDICATED IN SPECIFICATION SECTION 23 00 00.

ALL DUCTWORK AND HVAC EQUIPMENT SHALL BE INSULATED IN ACCORDANCE WITH

SPECIFICATION SECTION 23 07 00.

ALL DUCT ELBOWS, OFFSETS, ETC. SHALL BE MADE WITH RIGID SHEET METAL DUCT.

FLEXIBLE DUCT RUN OUTS TO AIR DISTRIBUTION DEVICES SHALL BE INSTALLED

ONLY IN VERTICAL POSITION AND SHALL NOT EXCEED 0.914m (3 FT.) IN LENGTH.

UNLESS OTHERWISE NOTED, CONTRACTOR SHALL PROVIDE AIR VOLUME BALANCING

DAMPERS ON ALL SUPPLY AND EXHAUST DUCT RUN OUT CONNECTIONS TO AIR

DISTRIBUTION DEVICES. DAMPERS SHALL BE INSTALLED NEAR BRANCH TAKE-OFF

LOCATIONS.

ALL FLOOR MOUNTED HVAC EQUIPMENT LOCATED IN THE MECHANICAL ROOM

SHALL BE INSTALLED ON AND ANCHORED TO EQUIPMENT BASE MOUNTING

FOOTING. FOOTING SHALL BE PRODUCED BY THE SAME MANUFACTURER AS THE

HVAC EQUIPMENT.

UNLESS OTHERWISE INDICATED, NON-ELECTRIC THERMOSTATIC VALVES WITH

INTEGRAL THERMOSTATIC SENSOR SHALL BE PROVIDED AS PART OF A PACKAGED

INTEGRATED RADIATOR. ALL OTHER ROOM THERMOSTATS NOT LOCATED ON

RADIATORS SHALL BE MOUNTED AT 1372 mm (4'-6") ABOVE THE FINISHED FLOOR.

ALL BASE MOUNTED PUMPS SHALL BE PROVIDED WITH VIBRATION ISOLATION AND

SHALL BE GROUTED IN PLACE ON TOP OF EQUIPMENT PADS.

DUCT AND FITTINGS SHALL BE PROVIDED AND INSTALLED IN ACCORDANCE WITH

SMACNA. HOWEVER, A MINIMUM OF 24 GAUGE SHEET METAL DUCT SHALL BE USED

FOR SUPPLY & RETURN DUCT FROM AHU-1, AHU-2, AND AHU-3 WHEN A THINNER

GAUGE IS SPECIFIED BY SMACNA.

UNLESS OTHERWISE INDICATED, PROVIDE OBD'S FOR AIR DISTRIBUTION DEVICES.

THE OBD'S SHALL BE LEFT IN THE FULL OPEN POSITION. AIR VOLUME BALANCING

DAMPERS SHALL ALSO BE PROVIDED AS INDICATED IN THESE NOTES AND AS

SHOWN ON THE PLANS.

ACCESS PANELS SHALL BE PROVIDE FOR ALL VALVES AND DAMPERS WHERE

ACCESS IS OTHERWISE NOT AVAILABLE.

10.

11.

12.

13.

14.

INSULATE ROOM CLOTHES DRYER AND ALL KITCHEN EXHAUST DUCTS A MINIMUM

DISTANCE OF 3.0m FROM THE PENETRATION OF THE EXERIOR WALL'S INNER SURFACE.

INSULATION TYPE SHALL BE PER UFGS 23 07 00, PARAGRAPH 2.4.1 WITH THICKNESS

PER TABLE 4.

FOR ALL CLOTHES DRYERS LOCATED IN LAUNDRY ROOMS, EXHAUST DUCT SHALL

BE INSULATED IN ANY SPACE OUTSIDE OF THE LAUNDRY ROOM. INSULATION TYPE

SHALL BE PER UFGS 23 07 00, PARAGRAPH 2.4.1 WITH THICKNESS PER TABLE 4.

ALL CLOTHES DRYER AND KITCHEN EXHAUST DUCT SHALL BE GALVANIZED METAL,

ROUND, HARD DUCT; FLEXIBLE AND VINYL DUCT SHALL NOT BE USED. COMPLY

WITH ALL MANUFACTURER'S INSTRUCTIONS. ENSURE ALL CONTECTIONS ARE POSITIVELY

SEALED TO PREVENT AIR LEAKAGE.

PROVIDE ACCESS FOR MAINTENANCE AND INSPECTION AT LOCATION BEFORE

PENETRATION THROUGH EXTERIOR WALL AND AT EVERY 4.5m INTERVALS AND

DUCT WORK SEAM CONNECTIONS. MINIMUM ACCESS DOOR SIZE SHALL BE NO LESS THAN

400mm X 400mm.

KEYED NOTES

1.

2.

3.

4.

5.

6.

AIR HANDLING UNIT WITH GLYCOL WATER HEATING COIL. ROUTE SUPPLY DUCT

TO THE AIR DISTRIBUTION DEVICES AS SHOWN. SEE DETAIL 1 ON SHEET M-502.

DRYER EXHAUST VENT. CONNECT VENT TO ARTIC EXHAUST HOOD. SEE DETAIL ON

SHEET A-515 FOR ACTUAL DIMENSIONS.

250mm X 250mm RETURN AIR TRANSFER DUCT WITH ACCOUSTICAL LINING. SEE

DETAIL 3 ON SHEET M-503.

FROST PROOF ARCTIC EXHAUST HOOD. SEE DETAIL ON SHEET A-515 FOR ACTUAL

DIMENSIONS.

FROST PROOF ARCTIC INTAKE HOOD. SEE DETAIL ON SHEET A-515 FOR ACTUAL

DIMENSIONS.

KITCHEN RANGE HOOD VENT. CONNECT VENT TO ARCTIC EXHAUST HOOD. SEE DETAIL

ON SHEET A-515 FOR ACTUAL DIMENSIONS.

SPACE PRESSURE SENSOR/TRANSMITTER. INSTALL WHERE SHOWN. SEE SHEET M-702

FOR ADDITIONAL REQUIREMENTS.

7.

UP DN

F

D W

UP DN

F

DW

F

DW

F

DW

F

DW

F

D W

F

D W

F

D W

F

D W

F

D W

F

D W

F

D W

F

D W

T

T

T

T

P

PART A

UH-4

CUH-1

AHU-2

3 3

3 3

2 2

0x

0x

0x

450x300

C 19.0 L/s

B 9.4 L/s

B 9.4 L/s

B 9.4 L/s

B 9.4 L/s A 9.4 L/s A 9.4 L/s

A 9.4 L/s

A 9.4 L/s

A 9.4 L/s

A 9.4 L/s A 9.4 L/s A 9.4 L/s

A 9.4 L/s A 9.4 L/s

A 9.4 L/s A 9.4 L/s

A 9.4 L/s A 9.4 L/sB 9.4 L/s

B 9.4 L/s

B 9.4 L/s B 9.4 L/s

A 24.0 L/s

A 24.0 L/s

A 24.0 L/sC 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

B 59.0 L/s

A 9.4 L/s

A 9.4 L/s

175ø 175ø

175ø

250ø

200ø

200ø

175ø 300x250

200ø

200ø

150x150

200ø

350x250

175ø

150ø

150ø

150x125

175ø

100ø 100ø

100ø

100ø

175ø

250ø

200ø

200ø

150ø

150ø

150x125

175ø 150ø

150ø

150ø

150ø 175ø

150ø

150ø

150x125

150x125400x250 450x300

250x150 250x150 250x200

175ø 150ø

150x125

150x125

175ø 150ø

150ø

150ø

175ø

150ø

150ø

300x200

450x300

5ø

250ø

250ø

175ø

400x250

300x200

150ø

150ø

400x300

150ø

150x150

150x125

150x125

150x125

150x125

750x500

VD

VD

VD VD

VD

VD

VD

VD

VD VD

VD

VD

VD

VD

CD

CD

CD CD

CD

CD

CD CD

CD

CD

CD

VD

VD

CD

200ø

VD VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD VD

VD

VD

VD

VD

150x125

150x125

VD

150x125

150x150

VD

175øHX-1/2, P-1/2

M-402

M-102A

MD

SF-2

MD

MD

MD

250ø

475ø

350ø

D 59.0 L/s

VD

B 80.0 L/s

VD

E 75.0 L/s

D 40.0 L/s

SECOND FLOOR

105960

SECOND FLOOR

105950

THIRD FLR

FRAMING

109530

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

D

AT

E:

SC

A L

E:

D R

A W

IN

G C

O D

E :

D

ES

IG

N

ED

BY

D R

A W N

BY

C H

E C

KE

D

BY

IS

S U

E D

AT

E:

D

AT

E:

EN

G

IN

EE

R

/A R

C H

IT

EC

T N

AM

E

PR

O

JE

C

T

EN

G

IN

EE

R

/A R

C H

IT

EC

T

U .S

.A R

M Y

EN

G

IN

EE

R D

IS

TR

IC

T

C O

R

PS

O F

EN

G

IN

EE

R S

N

EW

YO

R

K D

IS

TR

IC

T, N Y

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH: C:\Documents and Settings\E3ENDJM3\My Documents\MECH_FY12_THULE_DORM_E3ENDJM3.rvt

1/18/2012 11:15:24 AM

M-102A

JM

M

/C S

Au th or C h e ck er

FY

D O

R M

IT

O

R Y, TH

U

LE

AF

B, G

R

EE

N

LA

N D

M

EC

H

AN

IC

AL

H

VA

C

SE

C O

N D

FL

O

O R

-P

AR

T

PL

AN

A

M

AT

C H

LI

N

E

- S

EE

S

H

EE

T M

-1

B

FO

R C

O N

TI

N

U

AT

IO

N

1 : 100

MECHANICAL HVAC SECOND FLOOR - PART PLAN A

N

TRUE NORTH

WIND

PLAN NORTH

0 5,000MM 10,000MM

SCALE 1:100 (MILLIMETERS)

1 : 50

MAIN DUCT TRANSITION FROM MECHANICAL ROOM

R

EV

IS

ED

AI

R

FL

O W

FR

O

M D

IF

FU

SE

R

S 1/

/1

JM

M

AD

D

IT

IO

N

AL

EX

H

AU

ST

AN

D

AI

R

TR

AN

SF

ER

D U

C T

PR

O

VI

D

ED

1/

/1

JM

M

Ja n

Ja

2.

3.

4.

5.

6.

7.

8.

9.

ALL SUPPLY DUCTWORK AND ALL RETURN DUCTWORK SHALL BE CONSTRUCTED

FOR 1000 Pa (2" w.c.) PRESSURE CLASS. DUCTWORK SHALL BE SEALED IN

ACCORDANCE WITH REQUIREMENTS INDICATED IN SPECIFICATION SECTION 23 00 00.

ALL DUCTWORK AND HVAC EQUIPMENT SHALL BE INSULATED IN ACCORDANCE WITH

SPECIFICATION SECTION 23 07 00.

ALL DUCT ELBOWS, OFFSETS, ETC. SHALL BE MADE WITH RIGID SHEET METAL DUCT.

FLEXIBLE DUCT RUN OUTS TO AIR DISTRIBUTION DEVICES SHALL BE INSTALLED

ONLY IN VERTICAL POSITION AND SHALL NOT EXCEED 0.914m (3 FT.) IN LENGTH.

UNLESS OTHERWISE NOTED, CONTRACTOR SHALL PROVIDE AIR VOLUME BALANCING

DAMPERS ON ALL SUPPLY AND EXHAUST DUCT RUN OUT CONNECTIONS TO AIR

DISTRIBUTION DEVICES. DAMPERS SHALL BE INSTALLED NEAR BRANCH TAKE-OFF

LOCATIONS.

ALL FLOOR MOUNTED HVAC EQUIPMENT LOCATED IN THE MECHANICAL ROOM

SHALL BE INSTALLED ON AND ANCHORED TO EQUIPMENT BASE MOUNTING

FOOTING. FOOTING SHALL BE PRODUCED BY THE SAME MANUFACTURER AS THE

HVAC EQUIPMENT.

UNLESS OTHERWISE INDICATED, NON-ELECTRIC THERMOSTATIC VALVES WITH

INTEGRAL THERMOSTATIC SENSOR SHALL BE PROVIDED AS PART OF A PACKAGED

INTEGRATED RADIATOR. ALL OTHER ROOM THERMOSTATS NOT LOCATED ON

RADIATORS SHALL BE MOUNTED AT 1372 mm (4'-6") ABOVE THE FINISHED FLOOR.

ALL BASE MOUNTED PUMPS SHALL BE PROVIDED WITH VIBRATION ISOLATION AND

SHALL BE GROUTED IN PLACE ON TOP OF EQUIPMENT PADS.

DUCT AND FITTINGS SHALL BE PROVIDED AND INSTALLED IN ACCORDANCE WITH

SMACNA. HOWEVER, A MINIMUM OF 24 GAUGE SHEET METAL DUCT SHALL BE USED

FOR SUPPLY & RETURN DUCT FROM AHU-1, AHU-2, AND AHU-3 WHEN A THINNER

GAUGE IS SPECIFIED BY SMACNA.

UNLESS OTHERWISE INDICATED, PROVIDE OBD'S FOR AIR DISTRIBUTION DEVICES.

THE OBD'S SHALL BE LEFT IN THE FULL OPEN POSITION. AIR VOLUME BALANCING

DAMPERS SHALL ALSO BE PROVIDED AS INDICATED IN THESE NOTES AND AS

SHOWN ON THE PLANS.

ACCESS PANELS SHALL BE PROVIDE FOR ALL VALVES AND DAMPERS WHERE

ACCESS IS OTHERWISE NOT AVAILABLE.

10.

11.

12.

13.

14.

INSULATE ROOM CLOTHES DRYER AND ALL KITCHEN EXHAUST DUCTS A MINIMUM

DISTANCE OF 3.0m FROM THE PENETRATION OF THE EXERIOR WALL'S INNER SURFACE.

INSULATION TYPE SHALL BE PER UFGS 23 07 00, PARAGRAPH 2.4.1 WITH THICKNESS

PER TABLE 4.

FOR ALL CLOTHES DRYERS LOCATED IN LAUNDRY ROOMS, EXHAUST DUCT SHALL

BE INSULATED IN ANY SPACE OUTSIDE OF THE LAUNDRY ROOM. INSULATION TYPE

SHALL BE PER UFGS 23 07 00, PARAGRAPH 2.4.1 WITH THICKNESS PER TABLE 4.

ALL CLOTHES DRYER AND KITCHEN EXHAUST DUCT SHALL BE GALVANIZED METAL,

ROUND, HARD DUCT; FLEXIBLE AND VINYL DUCT SHALL NOT BE USED. COMPLY

WITH ALL MANUFACTURER'S INSTRUCTIONS. ENSURE ALL CONTECTIONS ARE POSITIVELY

SEALED TO PREVENT AIR LEAKAGE.

PROVIDE ACCESS FOR MAINTENANCE AND INSPECTION AT LOCATION BEFORE

PENETRATION THROUGH EXTERIOR WALL AND AT EVERY 4.5m INTERVALS AND

DUCT WORK SEAM CONNECTIONS. MINIMUM ACCESS DOOR SIZE SHALL BE NO LESS THAN

400mm X 400mm.

KEYED NOTES

1.

2.

250mm X 250mm RETURN AIR TRANSFER DUCT WITH ACCOUSTICAL LINING. SEE DETAIL 3

ON SHEET M-503.

KITCHEN RANGE HOOD VENT. CONNECT VENT TO ARTIC EXHAUST HOOD. SEE DETAIL ON

SHEET A-515 FOR ACTUAL DIMENSIONS.

UPDN

F

D W

F

D W

F

D W

F

D W

F

D W

F

D W

T

T

PART B

CUH-1

400x250

300x250 250x250

1 1 1 1

1 1 1 1

A 9.4 L/s A 9.4 L/s

A 9.4 L/s

A 9.4 L/s

A 9.4 L/sA 9.4 L/s A 9.4 L/s

A 9.4 L/s

A 9.4 L/s

A 9.4 L/s

A 9.4 L/s

A 9.4 L/s

A 9.4 L/s A 9.4 L/s A 9.4 L/s A 9.4 L/s

A 9.4 L/s

A 9.4 L/s A 9.4 L/s

A 9.4 L/sA 9.4 L/s

A 9.4 L/s

A 9.4 L/sA 9.4 L/sA 9.4 L/sA 9.4 L/s

A 9.4 L/s

A 9.4 L/s

A 9.4 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s C 19.0 L/s C 19.0 L/s C 19.0 L/s

C 19.0 L/s C 19.0 L/s C 19.0 L/s

C 19.0 L/s

C 19.0 L/s C 19.0 L/s

150x125

200x200

150ø

150ø

150ø

150ø150ø

150ø

400x250

250x200

150x125 150x125

150ø 150ø

150ø 150ø

150ø

175ø 175ø

250x150

150ø 150ø

150ø

150ø

150ø150ø

150ø 150ø

150x125

150x150

150ø

175ø

150ø

150ø

150ø 150ø

150x125

150x125

150ø150ø

175ø

200ø

200ø

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

CD

CD

CD

CD

CD

CD

VD

VD VD VD VD VD VD

VD

VD

VD

VDVD

VD

VD VD

VD VDVD VD VD VD

VD VD

VD VD

150x125

D 115.0 L/s 150x125

150x125

150x125150x125

0x

5 VD

2 2

2 2

B 59.0 L/s

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

D

AT

E:

SC

A L

E:

D R

A W

IN

G C

O D

E :

D

ES

IG

N

ED

BY

D R

A W N

BY

C H

E C

KE

D

BY

IS

S U

E D

AT

E:

D

AT

E:

EN

G

IN

EE

R

/A R

C H

IT

EC

T N

AM

E

PR

O

JE

C

T

EN

G

IN

EE

R

/A R

C H

IT

EC

T

U .S

.A R

M Y

EN

G

IN

EE

R D

IS

TR

IC

T

C O

R

PS

O F

EN

G

IN

EE

R S

N

EW

YO

R

K D

IS

TR

IC

T, N Y

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH: C:\Documents and Settings\E3ENDJM3\My Documents\MECH_FY12_THULE_DORM_E3ENDJM3.rvt

1/18/2012 11:15:31 AM

M-102B

JM

M

/C S

Au th or C h e ck er

FY

D O

R M

IT

O

R Y, TH

U

LE

AF

B, G

R

EE

N

LA

N D

M

EC

H

AN

IC

AL

H

VA

C

SE

C O

N D

FL

O

O R

-P

AR

T

PL

AN

B

M

AT

C H

LI

N

E

- S

EE

S

H

EE

T M

-1

A

FO

R C

O N

TI

N

U

AT

IO

N

1 : 100

MECHANICAL HVAC SECOND FLOOR - PART PLAN B

N

TRUE NORTH

WIND

PLAN NORTH

0 5,000MM 10,000MM

SCALE 1:100 (MILLIMETERS)

R

EV

IS

ED

PE

R

AM

EN

D

M

EN

T 1/

/1

JM

M

Ja

2.

3.

4.

5.

6.

7.

8.

9.

ALL SUPPLY DUCTWORK AND ALL RETURN DUCTWORK SHALL BE CONSTRUCTED

FOR 1000 Pa (2" w.c.) PRESSURE CLASS. DUCTWORK SHALL BE SEALED IN

ACCORDANCE WITH REQUIREMENTS INDICATED IN SPECIFICATION SECTION 23 00 00.

ALL DUCTWORK AND HVAC EQUIPMENT SHALL BE INSULATED IN ACCORDANCE WITH

SPECIFICATION SECTION 23 07 00.

ALL DUCT ELBOWS, OFFSETS, ETC. SHALL BE MADE WITH RIGID SHEET METAL DUCT.

FLEXIBLE DUCT RUN OUTS TO AIR DISTRIBUTION DEVICES SHALL BE INSTALLED

ONLY IN VERTICAL POSITION AND SHALL NOT EXCEED 0.914m (3 FT.) IN LENGTH.

UNLESS OTHERWISE NOTED, CONTRACTOR SHALL PROVIDE AIR VOLUME BALANCING

DAMPERS ON ALL SUPPLY AND EXHAUST DUCT RUN OUT CONNECTIONS TO AIR

DISTRIBUTION DEVICES. DAMPERS SHALL BE INSTALLED NEAR BRANCH TAKE-OFF

LOCATIONS.

ALL FLOOR MOUNTED HVAC EQUIPMENT LOCATED IN THE MECHANICAL ROOM

SHALL BE INSTALLED ON AND ANCHORED TO EQUIPMENT BASE MOUNTING

FOOTING. FOOTING SHALL BE PRODUCED BY THE SAME MANUFACTURER AS THE

HVAC EQUIPMENT.

UNLESS OTHERWISE INDICATED, NON-ELECTRIC THERMOSTATIC VALVES WITH

INTEGRAL THERMOSTATIC SENSOR SHALL BE PROVIDED AS PART OF A PACKAGED

INTEGRATED RADIATOR. ALL OTHER ROOM THERMOSTATS NOT LOCATED ON

RADIATORS SHALL BE MOUNTED AT 1372 mm (4'-6") ABOVE THE FINISHED FLOOR.

ALL BASE MOUNTED PUMPS SHALL BE PROVIDED WITH VIBRATION ISOLATION AND

SHALL BE GROUTED IN PLACE ON TOP OF EQUIPMENT PADS.

DUCT AND FITTINGS SHALL BE PROVIDED AND INSTALLED IN ACCORDANCE WITH

SMACNA. HOWEVER, A MINIMUM OF 24 GAUGE SHEET METAL DUCT SHALL BE USED

FOR SUPPLY & RETURN DUCT FROM AHU-1, AHU-2, AND AHU-3 WHEN A THINNER

GAUGE IS SPECIFIED BY SMACNA.

UNLESS OTHERWISE INDICATED, PROVIDE OBD'S FOR AIR DISTRIBUTION DEVICES.

THE OBD'S SHALL BE LEFT IN THE FULL OPEN POSITION. AIR VOLUME BALANCING

DAMPERS SHALL ALSO BE PROVIDED AS INDICATED IN THESE NOTES AND AS

SHOWN ON THE PLANS.

ACCESS PANELS SHALL BE PROVIDE FOR ALL VALVES AND DAMPERS WHERE

ACCESS IS OTHERWISE NOT AVAILABLE.

10.

11.

12.

13.

14.

INSULATE ROOM CLOTHES DRYER AND ALL KITCHEN EXHAUST DUCTS A MINIMUM

DISTANCE OF 3.0m FROM THE PENETRATION OF THE EXERIOR WALL'S INNER SURFACE.

INSULATION TYPE SHALL BE PER UFGS 23 07 00, PARAGRAPH 2.4.1 WITH THICKNESS

PER TABLE 4.

FOR ALL CLOTHES DRYERS LOCATED IN LAUNDRY ROOMS, EXHAUST DUCT SHALL

BE INSULATED IN ANY SPACE OUTSIDE OF THE LAUNDRY ROOM. INSULATION TYPE

SHALL BE PER UFGS 23 07 00, PARAGRAPH 2.4.1 WITH THICKNESS PER TABLE 4.

ALL CLOTHES DRYER AND KITCHEN EXHAUST DUCT SHALL BE GALVANIZED METAL,

ROUND, HARD DUCT; FLEXIBLE AND VINYL DUCT SHALL NOT BE USED. COMPLY

WITH ALL MANUFACTURER'S INSTRUCTIONS. ENSURE ALL CONTECTIONS ARE POSITIVELY

SEALED TO PREVENT AIR LEAKAGE.

PROVIDE ACCESS FOR MAINTENANCE AND INSPECTION AT LOCATION BEFORE

PENETRATION THROUGH EXTERIOR WALL AND AT EVERY 4.5m INTERVALS AND

DUCT WORK SEAM CONNECTIONS. MINIMUM ACCESS DOOR SIZE SHALL BE NO LESS THAN

400mm X 400mm.

KEYED NOTES

1.

2.

3.

4.

5.

6.

AIR HANDLING UNIT WITH GLYCOL WATER HEATING COIL. ROUTE SUPPLY DUCT

TO THE AIR DISTRIBUTION DEVICES AS SHOWN. SEE DETAIL 1 ON SHEET M-502.

DRYER EXHAUST VENT. CONNECT VENT TO ARTIC EXHAUST HOOD. SEE DETAIL ON

SHEET A-515 FOR ACTUAL DIMENSIONS.

250mm X 250mm RETURN AIR TRANSFER DUCT WITH ACCOUSTICAL LINING. SEE

DETAIL 3 ON SHEET M-503.

FROST PROOF ARCTIC EXHAUST HOOD. SEE DETAIL ON SHEET A-515 FOR ACTUAL

DIMENSIONS.

FROST PROOF ARCTIC INTAKE HOOD. SEE DETAIL ON SHEET A-515 FOR ACTUAL

DIMENSIONS.

KITCHEN RANGE HOOD VENT. CONNECT VENT TO ARCTIC EXHAUST HOOD. SEE DETAIL

ON SHEET A-515 FOR ACTUAL DIMENSIONS.

SPACE PRESSURE SENSOR/TRANSMITTER. INSTALL WHERE SHOWN. SEE SHEET M-702

FOR ADDITIONAL REQUIREMENTS.

7.

DN

DN

T

T

T

T

P

PART A

CUH-1

M-403

AHU-3

150ø

250x200 300x250 300x250 350x250 350x250

150ø

150ø 150ø

150ø

150ø

150ø 150ø

150ø

150ø

150ø

150ø

150ø 150ø

150ø 150ø

150ø

150ø

150ø 150ø

150ø 150ø

150ø

0x

400x250

150ø

200ø

150ø

150x150

150x150

150x150

150x150

150x150

250x150

150x150

150x150

250x150

150x150

150x150

250x200

200x200 150x150

150x150

150x150

400x250

150x150

450x300

400x300300x200 350x200

0x

150x150

300x200

175ø

175ø 175ø

175ø 175ø 175ø

250ø

250ø

175ø

175ø 175ø

175ø175ø175ø

250ø

250ø

B 9.4 L/s B 9.4 L/s B 9.4 L/s B 9.4 L/s B 9.4 L/s B 9.4 L/s

B 9.4 L/s B 9.4 L/s B 9.4 L/s B 9.4 L/s

B 9.4 L/s B 9.4 L/s

B 9.4 L/s B 9.4 L/s

B 9.4 L/s B 9.4 L/s

B 9.4 L/s B 9.4 L/s

B 9.4 L/s B 9.4 L/sB 9.4 L/sB 9.4 L/s

B 9.4 L/s

B 9.4 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

C 19.0 L/s

A 30.0 L/s

C 19.0 L/s

B 80.0 L/s

A 30.0 L/s

A 30.0 L/s

A 19.0 L/s

VD VD

VD

VD

VD

VD

VD

VD

VD

VD

VD VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

VD

CD CD

CD

CD

CDCDCD CD

CD

CD

VD

VD

VD

VD

175ø

CD

HX-3/4,

P-3/4

UH-4

UH-4

MD

750x500

M-40333

3 3

CD CD

150ø

SF-3

MD

MD

MD

D 45.0 L/s

D 87.0 L/s

D 59.0 L/s

US Army Corps of Engineers New York District

SY

M

BO

L

R

EV

IS

IO

N D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

D

AT

E:

SC

A L

E:

D R

A W

IN

G C

O D

E :

D

ES

IG

N

ED

BY

D R

A W N

BY

C H

E C

KE

D

BY

IS

S U

E D

AT

E:

D

AT

E:

EN

G

IN

EE

R

/A R

C H

IT

EC

T N

AM

E

PR

O

JE

C

T

EN

G

IN

EE

R

/A R

C H

IT

EC

T

U .S

.A R

M Y

EN

G

IN

EE

R D

IS

TR

IC

T

C O

R

PS

O F

EN

G

IN

EE

R S

N

EW

YO

R

K D

IS

TR

IC

T, N Y

SHEET

REFERENCE

NUMBER:

DATE:

FILE PATH: C:\Documents and Settings\E3ENDJM3\My Documents\MECH_FY12_THULE_DORM_E3ENDJM3.rvt

1/18/2012 1:42:27 PM

M-103A

JM

M

/C S

Au th or C h e ck er

FY

D

O R

M

IT

O R

Y, T

H U

LE

A

FB

, G

R

EE

N

LA

N D

M

EC

H

AN

IC

AL

H

VA

C

TH

IR

D

FL

O

O R

-P

AR

T

PL

AN

A

M

AT

C H

LI

N

E

- S

EE

S

H

EE

T M

-1

B

FO

R C

O N

TI

N

U

AT

IO

N

1 : 100

ENLARGED THIRD FLOOR MECHANICAL ROOM PLAN

N

TRUE NORTH

WIND

PLAN NORTH

0 5,000MM 10,000MM

SCALE 1:100 (MILLIMETERS)

R

EV

IS

ED

A

IR

FL

O W

F R

O M

D

IF

FU

SE

R S

1/

/1

JM

M

AD

D

IT

IO

N

AL

E

XH

AU

ST

A

N D

A

IR

T R

AN

SF

ER

D

U C

T

PR

O

VI

D

ED

1/

/1

JM

M

Ja n

Ja

2.

3.

4.

5.

6.

7.

8.

9.

ALL SUPPLY DUCTWORK AND ALL RETURN DUCTWORK SHALL BE CONSTRUCTED

FOR 1000 Pa (2" w.c.) PRESSURE CLASS. DUCTWORK SHALL BE SEALED IN

ACCORDANCE WITH REQUIREMENTS INDICATED IN SPECIFICATION SECTION 23 00 00.

ALL DUCTWORK AND HVAC EQUIPMENT SHALL BE INSULATED IN ACCORDANCE WITH

SPECIFICATION SECTION 23 07 00.

ALL DUCT ELBOWS, OFFSETS, ETC. SHALL BE MADE WITH RIGID SHEET METAL DUCT.

FLEXIBLE DUCT RUN OUTS TO AIR DISTRIBUTION DEVICES SHALL BE INSTALLED

ONLY IN VERTICAL POSITION AND SHALL NOT EXCEED 0.914m (3 FT.) IN LENGTH.

UNLESS OTHERWISE NOTED, CONTRACTOR SHALL PROVIDE AIR VOLUME BALANCING

DAMPERS ON ALL SUPPLY AND EXHAUST DUCT RUN OUT CONNECTIONS TO AIR

DISTRIBUTION DEVICES. DAMPERS SHALL BE INSTALLED NEAR BRANCH TAKE-OFF

LOCATIONS.

ALL FLOOR MOUNTED HVAC EQUIPMENT LOCATED IN THE MECHANICAL ROOM

SHALL BE INSTALLED ON AND ANCHORED TO EQUIPMENT BASE MOUNTING

FOOTING. FOOTING SHALL BE PRODUCED BY THE SAME MANUFACTURER AS THE

HVAC EQUIPMENT.

UNLESS OTHERWISE INDICATED, NON-ELECTRIC THERMOSTATIC VALVES WITH

INTEGRAL THERMOSTATIC SENSOR SHALL BE PROVIDED AS PART OF A PACKAGED

INTEGRATED RADIATOR. ALL OTHER ROOM THERMOSTATS NOT LOCATED ON

RADIATORS SHALL BE MOUNTED AT 1372 mm (4'-6") ABOVE THE FINISHED FLOOR.

ALL BASE MOUNTED PUMPS SHALL BE PROVIDED WITH VIBRATION ISOLATION AND

SHALL BE GROUTED IN PLACE ON TOP OF EQUIPMENT PADS.

DUCT AND FITTINGS SHALL BE PROVIDED AND INSTALLED IN ACCORDANCE WITH

SMACNA. HOWEVER, A MINIMUM OF 24 GAUGE SHEET METAL DUCT SHALL BE USED

FOR SUPPLY & RETURN DUCT FROM AHU-1, AHU-2, AND AHU-3 WHEN A THINNER

GAUGE IS SPECIFIED BY SMACNA.

UNLESS OTHERWISE INDICATED, PROVIDE OBD'S FOR AIR DISTRIBUTION DEVICES.

THE OBD'S SHALL BE LEFT IN THE FULL OPEN POSITION. AIR VOLUME BALANCING

DAMPERS SHALL ALSO BE PROVIDED AS INDICATED IN THESE NOTES AND AS

SHOWN ON THE PLANS.

ACCESS PANELS SHALL BE PROVIDE FOR ALL VALVES AND DAMPERS WHERE

ACCESS IS OTHERWISE NOT AVAILABLE.

10.

11.

12.

13.

14.

INSULATE ROOM CLOTHES DRYER AND ALL KITCHEN EXHAUST DUCTS A MINIMUM

DISTANCE OF 3.0m FROM THE PENETRATION OF THE EXERIOR WALL'S INNER SURFACE.

INSULATION TYPE SHALL BE PER UFGS 23 07 00, PARAGRAPH 2.4.1 WITH THICKNESS

PER TABLE 4.

FOR ALL CLOTHES DRYERS LOCATED IN LAUNDRY ROOMS, EXHAUST DUCT SHALL

BE INSULATED IN ANY SPACE OUTSIDE OF THE LAUNDRY ROOM. INSULATION TYPE

SHALL BE PER UFGS 23 07 00, PARAGRAPH 2.4.1 WITH THICKNESS PER TABLE 4.

ALL CLOTHES DRYER AND KITCHEN EXHAUST DUCT SHALL BE GALVANIZED METAL,

ROUND, HARD DUCT; FLEXIBLE AND VINYL DUCT SHALL NOT BE USED. COMPLY

WITH ALL MANUFACTURER'S INSTRUCTIONS. ENSURE ALL CONTECTIONS ARE POSITIVELY

SEALED TO PREVENT AIR LEAKAGE.

PROVIDE ACCESS FOR MAINTENANCE AND INSPECTION AT LOCATION BEFORE

PENETRATION THROUGH EXTERIOR WALL AND AT EVERY 4.5m INTERVALS AND

DUCT WORK SEAM CONNECTIONS. MINIMUM ACCESS DOOR SIZE SHALL BE NO LESS THAN

400mm X 400mm.

KEYED NOTES

1.

2.

250mm X 250mm RETURN AIR TRANSFER DUCT WITH ACCOUSTICAL LINING. SEE DETAIL 3

ON SHEET M-503.

KITCHEN RANGE HOOD VENT. CONNECT VENT TO ARTIC EXHAUST HOOD. SEE DETAIL ON

SHEET A-515 FOR ACTUAL DIMENSIONS.

DN

F

D W

F

D W

F

D W

F

D W

F

D W

F

D W

F

D W

F

D W

T

T

PART B

CUH-1

1 1

1 1

400x250

150ø

150ø

150ø

150ø

150ø

150ø

150ø

150ø

150ø

150ø

150ø 150ø 150ø

150ø

150ø

150ø

400x250 400x250 300x250 250x250

150ø

150ø

250x200

200ø

150ø

150ø150ø

150ø

150ø 150ø

150x150

150x150

250x200

150x150

150x150 150x150

250x150 150x150 150x150

150x150 150x150

150x150 150x150

150x150

150x150

175ø

175ø 175ø

175ø

175ø

175ø

175ø

200ø

200ø200ø

200ø

175ø

B 9.4 L/s B 9.4 L/s

B 9.4 L/s B 9.4 L/s B 9.4 L/s B 9.4…