USMA_SCICTR_PN59044-09_STRU_Part 2.pdf
PDF 46 MB Posted
- Attached to
- Multipurpose Academic Building Science Facility Phase 2, which is located at the USMA West Point NY
- Solicitation number
- W912DS-11-B-0005
About this file
90 Design - Structural Part 2
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CL
P
ABBREVIATIONS
HEATING/VENTILATING/AIR CONDITIONING
CANTILEVER(ED)CANT
FLOOR DRAIN(S)
FAR FACE
FOUNDATION(S)
FLEXIBLE
FULL LENGTH
FLANGE(S)
FACE TO FACE
CONTROL JOINTCJ
COLUMN
COMPRESSION
COMPRESSIBLE
CONCRETE MASONRY UNIT
CEILING
CPRS
COMP
COL
CMU
CLR
CLG
CLEAR
CAST IN PLACE
CEM CEMENT
CIP
FIN FINISH(ED)(ES)(ING)
FLR
FLG
FL
FLEX
FLOOR(S)
FDN, FDTN
FF
FD
F/F
LONG LEG VERTICAL
LOW POINT
LONGITUDINAL
LONG LEG HORIZONTAL
LIVE LOAD
LONG
LP
LOC
LLV
LLH
LL
LOCATION
POUND(S)
LEVEL(ING)
LONG, LENGTHLG
LEV
LB
DEAD LOAD
EACH END
ELEVATION(S)
ENCLOSE(S)(D)(URE)
ELEVATOR(S)
EMBEDDED, EMBEDMENT
EACH FACE
ELECTRIC(AL)
EXPANSION JOINT(S)
EACH SIDE
EACH WAY
EXPANSION
EXCAVATE(ION)
EXTERIOR
EQUIPMENT
DIMENSION(S)
EJ
BETWEEN
CENTER LINE
CENTER TO CENTER
CAISSON
BRACKET
BASEMENT
BENT
C/C
CAIS
BTWN
BSMT
BT
BRKT
C
BASEPLATE
BEARING
BRIDGING
BUILDING
BLOCKING
BRG
BRDG
BOT
B PL
BOTTOM
BLKG
BLK
BLDG
BLOCK
EXT
EXP
EXC
EW
ES
EQ
EQUIP
EQUAL(S)
ELEV
ENCL
EMBED
ELEC
EL
B
BITUMINOUS
BOTH FACES, BELOW FLOOR
BALANCE
BF
BITUM
B/, BOT
BAL
BOTTOM OF, BELOW
AVERAGE(S)
ASPHALT
ARCHITECT(URAL)
AVG
ARCH
ASPH
DWL DOWEL(S)
EA EACH
EF
EE
E EAST
DWG DRAWING(S)
DL
DN
DK
DIM
DOWN
DECK(S)
INCLUDE(ED)(ING)INCL
F
KIPS PER FOOTK/F
K
JST
JT
KIPS
JOINT
JOIST
L
K
INTERIOR(S)
INFORMATION
INSULATION
INFO
INT
INV
INSUL
INVERT
J
E
INSIDE DIAMETER
INSIDE FACEIF
IN
ID
INCH(ES)
HVAC
I
HORIZONTAL
HIGH POINT
HOLLOW CORE
HORIZ
HP
HK HOOK
HT
HC
HEIGHT
DIAPHRAGM
DIAGONAL
DIAMETER
DEPRESSION
DEGREE(S)
APPROXIMATE(LY)
ALTERNATE(S)(ING)
ALUMINUM
APPROX
ALT
AL, ALUM
ADDITIONAL
ADJACENT, ADJUST(ABLE)
ABOVE FINISHED GRADE
ABOVE FINISHED FLOOR
ANCHOR(S)
AGGREGATE
AFG
AGGR
ANCH
AFF
ADD'L
ADJ
DIAPH
DIAG
DIA, Ø
DET DETAIL(S)
DBL
DEPR
DEG, °
DOUBLE
ANCHOR BOLT(S)
ABV
AB
ABOVE
AT
AND
A
D
GR GRADE
H
GAGE, GAUGE
GENERAL CONTRACTOR
GALVANIZE(D)(S)GALV
GEN
GC
GENERAL
GA
G
WORKPOINT
WATERSTOP
DOUBLE EXTRA STRONG
WELDED WIRE FABRIC
WIND LOAD
UTILITY(IES)
VAPOR BARRIER
UNLESS NOTED OTHERWISE
POUNDS PER SQ FTPSF
POLYTETRAFLUOROETHYLENE
POUNDS PER SQ IN
PTFE
PT
PSI
POINT
XX
YD YARD
X EXTRA STRONG
PROPERTY
PREFABRICATED
PLUMBING
PERIMETER
PROFESSIONAL ENGINEER
PRECAST CONCRETE
PROP
PREFAB
PLMB
PLYW
PL,
PLYWOOD
PLATE
PERIM
PE
PCC
ON CENTER
OUTSTANDING LEG
OVERHEAD
OUTSIDE FACE
OUTSIDE DIAMETER
OUT TO OUT
OPNG OPENING
PAR PARALLEL
OZ
OPP
OSL
OUNCE
OPPOSITE
OH
OF
OC
OD
O/O
P
O
SPEC SPECIFICATION
SUSPENDED
SYMMETRICALSYM
SUP
SUSP
SUPPORT
STAINLESS STEEL
STIFFEN(ER)
STRUCTURE(AL)STRUCT
STIR
STL STEEL
STIRRUP
SST
STIFF
STD
STA
SQ
STANDARD
STATION
SQUARE
WWF
WS
WT WEIGHT
WPT
WL
WD WOOD
W/O W/
WITHOUT
WITH
SLAB
SPACE(S)(ING)
SLAB ON GRADE
SLEEVESLV
SOG
SPA
SHT
SL
SIM
SHEET
SIMILAR
SHALL CONFORM WITH
SEC
SECT
SECOND
SECTION
SCHED
SCW
SCHEDULE
VOL
VERT
VOLUME
VERTICAL
V
VB
VENT
UTIL
UNO
X
Y
W
V
U
TOP & BOTTOM
TEMPERATURE
TOP LAYER
TOLERANCE
MTL METAL
MINIMUM
NEAR FACE
NOT TO SCALE
NEAR SIDE
NOT APPLICABLE
MARK
MEZZANINE
MANUFACTURER
NTS
NOM
NS
NOMINAL
N/A
NF
(N)
#, NO.
NEW
NUMBER
MK
MO MASONRY OPENING
MISC
MIN
MEZZ
MFR
MISCELLANEOUS
N
MECHANICALMECH
MAX
MATL
MAXIMUM
MATERIAL
MAS MASONRY
M
RD ROOF DRAIN
RND
RM
ROUND
ROOM
S
RIGHT END
REFERENCE(D)(S)
REINFORCING
REVISE(D)(ION)
RECTANGULAR
REINF
REQ'D
REV
REQUIRED
REF
RECT
RE
TYP TYPICAL
TOT
TOL
TOTAL
TENSIONTEN
THK'N
TL
THK
THICKEN(ED)
THICK
TEMP
R, RAD
R RISER
RADIUS
QTY QUANTITY
Q
R
T & B T/
T
TOP OF
TREAD
T
LONG WAY TOPLWT
LWTB LONG WAY TOP AND BOTTOM
LWB LONG WAY BOTTOM
LW LONG WAY
, CL
CSK COUNTERSINK(SUNK)
CENTERCTR
CONCRETE
CONNECTION
CONSTRUCTION
CONTINUE(OUS)(ATION)
CONTRACTOR(S)
COORDINATE(S)
CONC
CONN
CONSTR
CONT
COORD
CONTR
FTG
FUT
FURN
FT
FOOTING(S)
FUTURE
FURNISH(ED)(ES)
FOOT, FEET
EOS EDGE OF SLAB
# POUND
LWGT LIGHTWEIGHT
DITTOdo
ISOLATION JOINTIJ
HD HEADED
VERIFY IN FIELDVIF
CAPACITYCAP
GB GRADE BEAM
L ANGLE
KIPS PER SQUARE FOOTKSF
KNOCKOUT PANELKOP
BEARING PLATE
BP, BRG PL
EXISTING(E), EXIST
HDR HEADER
N NORTH
DEEPDP
OPP HD OPPOSITE HAND
SJI STEEL JOIST INSTITUTE
BUILDING LINEB BLL
CENTER GRAVITY OF STEELCGS
SC SLIP CRITICAL
LSH LONG SIDE HORIZONTAL
COLD FORMED STEELCFS
EOD EDGE OF DECK
PERPENDICULARPERP
DEMOLISH(TION)DEMO
BASE PLATE, BEARING PLATE
LONGITUDINALLONGIT
FACTOR OF SAFETY
COUNTER CLOCKWISECCW
FOS
ENGINEER(S)(ING)
EACH WAY TOP
BOTTOM LAYERBL
BM BEAM
EWT
ENG
ABBREVIATION(S)
ARCHITECT/ENGINEER
ABBRV
A/E
POST-TENSIONP/T, PTEN
ON GAGE LINE
OVERALL
OGL
OA
SHORT WAY BOTTOMSWB
SW SHORT WAY, SWITCH
RMV REMOVE
REINFORCING BAR
REL RELOCATE
REBAR
EWB EACH WAY BOTTOM
EWTB EACH WAY TOP AND BOTTOM
SWT SHORT WAY TOP
SWTB SHORT WAY TOP AND BOTTOM
FR
FP
FRAME(D)(S)
FULL PENETRATION
BC BOTTOM CHORD
GRD GROUND
HDG HOT-DIPPED GALVANIZED
LT LEFT
CO CONTRACTING OFFICER
TOP CHORDTC
L
S2-1
A
S2-1
XX
XX
GRAPHIC SYMBOLS
EXISTING COLUMN LINE
NEW COLUMN LINE
SHEET WHERE DRAWN
SHEET WHERE DRAWN
DETAIL LETTER
SECTION NUMBER
REINFORCED CONCRETE SLAB ELEVATION TRANSITION
SYMBOL
DATUM
PLAN VIEW SECTION VIEW
NEW STEEL BEAM
NEW SLAB
NEW CONCRETE WALL
(E) 14x28
W16X26
EXIST CONCRETE
BEAM
753 EAST
EXISTING CONCRETE WALL
NEW RAMP OVER SLAB
(E) W21x57
EXIST STEEL BEAM
753 WEST & SOUTH
UNDERPINNING OF (E) FOUNDATIONS
SHEET
REFERENCE
NUMBER
SHEET OF
D
ES
IG
N
E D
B Y:
D W
N B
Y:
C
H K
BY
S U
BM
IT
TE
D
B Y:
D
AT
E:
S O
LI
C
IT
A
TI
O
N N
O
C O
N
TR
A C
T N
O
FI
LE
N A
M E:
P
LO
TT
E
D B
Y:
S
IZ
E:
P
LO
T D
A
TE
D
AT
E:
D
ES
C
R
IP
TI
O
N
M
AR
K:
A
PP
R
US ARMY CORPS
OF ENGINEERS
NEW YORK DISTRICT
1 2 3 4 5
D
C
B
A
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
N
EW
Y O
R K ht tp w w w
.n an
.u sa ce .a rm y.
m il ar ch ite ct s
- e ng in ee rs pl an ne rs
W
ES
T
N
AT
IO
N
W
ID
E
BL
VD
C O
LU
M
BU
S, O H
IO
4.
4.
fa x
4.
4.
ht tp w w w
.u rs co rp
.c om
SC
IE
N C
E C
EN
TE
R (F
Y1 1-
B
LD
G
U N
IT
ED
S
TA
TE
S
M
IL
IT
AR
Y
AC
AD
EM
Y W
ES
T
PO
IN
T, N
Y
A R
C H
D
PA
R
K
AV
EN
U
E
SO
U
TH
N
EW
Y O
R K, N Y
3-
2.
7.
fa x
2.
9.
w w w
.s tv in c.
co m
W
2D S
-1 0-
D -0
3/
/2
3:
:2
P
M
S-001
ST
R
U C
TU
R
AL
L
EG
EN
D S
AN
D
AB
BR
EV
IA
TI
O
N S
C
LH
JD
B
SH
A
P R
IL
SHEET
REFERENCE
NUMBER
SHEET OF
D
ES
IG
N
E D
B Y:
D W
N B
Y:
C
H K
BY
S U
BM
IT
TE
D
B Y:
D
AT
E:
S O
LI
C
IT
A
TI
O
N N
O
C O
N
TR
A C
T N
O
FI
LE
N A
M E:
P
LO
TT
E
D B
Y:
S
IZ
E:
P
LO
T D
A
TE
D
AT
E:
D
ES
C
R
IP
TI
O
N
M
AR
K:
A
PP
R
US ARMY CORPS
OF ENGINEERS
NEW YORK DISTRICT
1 2 3 4 5
D
C
B
A
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
N
EW
Y O
R K ht tp w w w
.n an
.u sa ce .a rm y.
m il ar ch ite ct s
- e ng in ee rs pl an ne rs
W
ES
T
N
AT
IO
N
W
ID
E
BL
VD
C O
LU
M
BU
S, O H
IO
4.
4.
fa x
4.
4.
ht tp w w w
.u rs co rp
.c om
SC
IE
N C
E C
EN
TE
R (F
Y1 1-
B
LD
G
U N
IT
ED
S
TA
TE
S
M
IL
IT
AR
Y
AC
AD
EM
Y W
ES
T
PO
IN
T, N
Y
A R
C H
D
PA
R
K
AV
EN
U
E
SO
U
TH
N
EW
Y O
R K, N Y
3-
2.
7.
fa x
2.
9.
w w w
.s tv in c.
co m
W
2D S
-1 0-
D -0
3/
/2
3:
:3
P
M
S-002
ST
R
U C
TU
R
AL
G
EN
ER
AL
N
O
TE
S
C
LH
B
JS
SH
A
P R
IL
SHEET
REFERENCE
NUMBER
SHEET OF
D
ES
IG
N
E D
B Y:
D W
N B
Y:
C
H K
BY
S U
BM
IT
TE
D
B Y:
D
AT
E:
S O
LI
C
IT
A
TI
O
N N
O
C O
N
TR
A C
T N
O
FI
LE
N A
M E:
P
LO
TT
E
D B
Y:
S
IZ
E:
P
LO
T D
A
TE
D
AT
E:
D
ES
C
R
IP
TI
O
N
M
AR
K:
A
PP
R
US ARMY CORPS
OF ENGINEERS
NEW YORK DISTRICT
1 2 3 4 5
D
C
B
A
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
N
EW
Y O
R K ht tp w w w
.n an
.u sa ce .a rm y.
m il ar ch ite ct s
- e ng in ee rs pl an ne rs
W
ES
T
N
AT
IO
N
W
ID
E
BL
VD
C O
LU
M
BU
S, O H
IO
4.
4.
fa x
4.
4.
ht tp w w w
.u rs co rp
.c om
SC
IE
N C
E C
EN
TE
R (F
Y1 1-
B
LD
G
U N
IT
ED
S
TA
TE
S
M
IL
IT
AR
Y
AC
AD
EM
Y W
ES
T
PO
IN
T, N
Y
A R
C H
D
PA
R
K
AV
EN
U
E
SO
U
TH
N
EW
Y O
R K, N Y
3-
2.
7.
fa x
2.
9.
w w w
.s tv in c.
co m
W
2D S
-1 0-
D -0
3/
/2
3:
:5
P
M
S-003
ST
R
U C
TU
R
AL
G
EN
ER
AL
N
O
TE
S
C
LH
JD
B
SH
A
P R
IL
T/SLAB
FLR SLAB NOT SHOWN
WWF 6x6-W2.9xW2.9
T/SLAB
TYPICAL ISOLATION PAD
TYPICAL HOUSEKEEPING PAD
COORD SIZE, QTY, & LOC OF EQUIP BOLTS IF REQ'D & PAD
W/EQUIP SUPPLIER'S CERT DWG SEE ARCH, MECH, ELEC &
PROCESS DWG FOR LOC OF EQUIP PADS
FOR EQUIP (COORD W/
PLAN DIMS AS REQUIRED
APPROVED FOR SHOP DWGS)
6"
#4 @ 8" EW @
MID-DEPTH
IJ W/BOND
BREAKER
6"
FOR EQUIP (COORD W/
PLAN DIMS AS REQUIRED
APPROVED FOR SHOP DWGS)
FOR EQUIP (COORD W/
PLAN DIMS AS REQUIRED
EQ SP
A
1. LOCATE ALL CONSTRUCTION JOINTS ON THE SHOP DRAWINGS
2. WATERSTOPS NOT REQ'D IN ABOVE GRADE WALLS.
2 LAYER OF REINFORCING
1 LAYER OF REINFORCING
SCW BAR CLR
TABLE #2
SCW BAR CLR
TABLE #2
CONT KEY W/WS
3 EQ SPA
CONT KEY W/WS
PROVIDE BONDING AGENT
TYP SIKA ARMATEC 110
OR EQ
TABLE #1
LAP SCREW
PROVIDE BONDING AGENT
TYP SIKA ARMATEC 110
OR EQ
TABLE #1
LAP SCREW
OF SLAB
1/2" COMPR FILLER x
WIDTH & DEPTH OF
SLAB TYP
MID-DEPTH
#4 @ 12" @
4' -0
M
IN
2'
- 0
" T
YP
OPNG
(1) #4 @ MID DEPTH
OF SLAB
MAS OR CONC WALL
BELOW
CORE 6"Ø HOLE EA
CORNER OF (N) OPNG
PRIOR TO SAWCUTTING
OPNG
CHIP OUT CORNERS AS
REQ'D TO SQ UP OPNG
(E) CONC FLR
(N) OPNG SEE ARCH
FOR SIZE & LOC
SAWCUT & REMOVE
(E) CONC
DO NOT OVERCUT
CORNERS (SAWCUT ONLY
TO CORED HOLES)
SC
W
B A
R
0"
2 LAYERS OF REINFORCING
CONSTR JT
DWL TO MATCH
SIZE & SPA OF
WALL HORIZ REINF
C
LR
T A
B
LE
TY
P
CORNER BARS TO
MATCH SIZE & SPA OF
WALL HORIZ REINF
PROVIDE ADD'L VERT
BAR @ CORNER
LA
P
ST
D
H K
LAP
TABLE #1 TYP
LAP SCW
1 LAYERS OF REINFORCING
CONSTR JT
CORNER BARS TO
MATCH SIZE & SPA OF
WALL HORIZ REINF
CTR REINF IN CTR
OF WALL UNO
DWL TO MATCH
SIZE & SPA OF
WALL HORIZ REINF
LAPST
D
H K
SEE D3/S-004 FOR SLAB DETAILS.
T/SLAB
SAWCUT SLAB EDGE. PLACE IJ
FILLER, FULL DEPTH OF NEW
SLAB. CAP W/JT FILLER.
NEW MUD-MAT OR
GRANULAR SUB-GRADE
MAINTAIN SOIL COMPACTION
WITHIN 2" OF SLAB CUT-
EDGE.
COORDINATE SLAB REMOVAL AREAS WITH BUILDING
DEMOLITION PLANS AND PLUMBING DEMOLITION AND
NEW PIPING INSTALLATIONPLANS.
FOR SLAB REPLACEMENT > 36" WIDTH,
PROVIDE #4 DOWELS AT 18" O.C., DRILL &
EPOXY DOWEL INTO EXISTING W/ 6" EMBED,
18" EXTENSION.
(N) VAPOR BARRIER,
SPLICE/SEAL TO EXISTING.
T
(2) #5x4'-0" @ EA
CORNER (1) EF
RND/SQ OPNG
HK BARS
INTERRUPTED
BY OPENING
1/2 # OF BARS (@ 3" OC)
INTERRUPTED BY OPNG
+ (2) #5 T & B TYP ON EF
OF OPNG
NOTE:
ALL HOLES & CUT OUTS IN THE FLOOR SLAB(S) & WALLS SHALL
BE EITHER FORMED OR PROVIDED W/PIPE SLEEVES BEFORE
POURING CONC. HOLES SHALL NOT BE DRILLED OR CUT
WITHOUT THE WRITTEN PERMISSION OF CONTRACTING OFFICER.
3" 3"
TA
B
LE
LA
P
SC
W
TY
P
2'
0" M
A X
U N
O
4" M
IN
T/SLAB
NOTE: T=SLAB THK
WWF
EXTEND CONC ENCASEMENT
ALONG EMBEDDED CONDUIT,
TO A MIN OF 2" BELOW AND
EA SIDE OF CONDUIT.
RECESSED FLOOR BOX, BY
ELECTRICAL. COORDINATE
FOR QUANTITY AND LOCATION.
MUD-MAT OR
GRANULAR
SUB-GRADE
VAPOR BARRIER
SEE C2/S-004 FOR
JOINT @ EXIST.
1/ 3T
1'-6" (MIN)4" MIN4" MIN
PL
AN
SE
E
1/
T 2"
M
IN
1/
T
1/10 T
1/8" SAWCUT AFTER ADJ SLAB
IS IN PLACE & FILL W/JT FILLER
NOTE: T=SLAB THK
WWF
DISCONTINUE 50%
OF REINF @ JT
KEYED JT @
CTR OF SLAB
3/4" MIN
BREAK BOND ON JT
FACE W/2 COATS OF
FORM RELEASE OIL
T/SLAB
VAPOR BARRIER
MUD-MAT OR
GRANULAR
SUB-GRADE
T
SUBGRADE
3.
1.
2.
NOTE:
T/SLAB
WWF OR REBAR
CONC SOG
VAPOR BARRIER
THICKENED SLAB AT
NON-LOAD BEARING
WALLS (IF SPECIFIED
ON PLAN)
SUBGRADE SHALL BE PREPARED PER THE GEOTECHNICAL REPORT PRIOR TO SLAB PLACEMENT.
SEE GEOTECHNICAL REPORT FOR ADDITIONAL SUBGRADE PREPARATION REQUIREMENTS.
SLAB SHALL BE PLACED A MINIMUM OF 90 DAYS PRIOR TO INSTALLATION OF FLOOR FINISHES.
MUD-MAT OR
GRANULAR
SUB-GRADE
3"
PL
AN
SE
E
1/ 4T 1/ 3T
DISCONTINUE 50% OF
REINF @ JT
1/8" SAWED JT FILL
W/JT FILLER
NOTE: T = SLAB THK
T/SLAB
WWF
VAPOR BARRIER MUD-MAT OR
GRANULAR
SUB-GRADE
T
8"
8"
3'-0" 2" CLR TYP
T
2" CLR TYP
TYPICAL DEPRESSION GREATER THAN 4"
TYPICAL DEPRESSION LESS THAN 4"
(2) #4 CONT
WWF
#3 BT BARS
@ 12" OC
WWF
#4 NOSING BAR
SEE ARCH FOR
DEPTH OF DEPR
WWF
1:2 SLOPE
MAX
#4 NOSING BAR
#4 @ 12" OC
MAX
T/SLAB
T/SLAB
T/SLAB
MIN
MIN
VAPOR BARRIER
VAPOR BARRIER
MUD-MAT OR
GRANULAR
SUB-GRADE
MUD-MAT OR
GRANULAR
SUB-GRADE
SE
E
A R
C H
T/SLAB
T
SHEET
REFERENCE
NUMBER
SHEET OF
D
ES
IG
N
E D
B Y:
D W
N B
Y:
C
H K
BY
S U
BM
IT
TE
D
B Y:
D
AT
E:
S O
LI
C
IT
A
TI
O
N N
O
C O
N
TR
A C
T N
O
FI
LE
N A
M E:
P
LO
TT
E
D B
Y:
S
IZ
E:
P
LO
T D
A
TE
D
AT
E:
D
ES
C
R
IP
TI
O
N
M
AR
K:
A
PP
R
US ARMY CORPS
OF ENGINEERS
NEW YORK DISTRICT
1 2 3 4 5
D
C
B
A
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
N
EW
Y O
R K ht tp w w w
.n an
.u sa ce .a rm y.
m il ar ch ite ct s
- e ng in ee rs pl an ne rs
W
ES
T
N
AT
IO
N
W
ID
E
BL
VD
C O
LU
M
BU
S, O H
IO
4.
4.
fa x
4.
4.
ht tp w w w
.u rs co rp
.c om
SC
IE
N C
E C
EN
TE
R (F
Y1 1-
B
LD
G
U N
IT
ED
S
TA
TE
S
M
IL
IT
AR
Y
AC
AD
EM
Y W
ES
T
PO
IN
T, N
Y
A R
C H
D
PA
R
K
AV
EN
U
E
SO
U
TH
N
EW
Y O
R K, N Y
3-
2.
7.
fa x
2.
9.
w w w
.s tv in c.
co m
W
2D S
-1 0-
D -0
3/
/2
3:
:0
P
M
S-004
TY
PI
C
AL
D
ET
AI
LS
C
LH
B
JS
SH
A
P R
IL
SCALE: N.T.S.A1 TYPICAL EQUIPMENT PAD DETAILS
SCALE: N.T.S.A2
TYPICAL CONCRETE WALL
CONSTRUCTION JOINT
SCALE: N.T.S.A3
TYP PLAN - REINF IN SOG AT WALL
OPENINIG
SCALE: N.T.S.A5
TYPICAL NEW OPENING IN EXISTING
CONCRETE FLOOR/WALL
SCALE: N.T.S.C1 TYPICAL CONCRETE WALL CORNER
SCALE: N.T.S.C2
TYPICAL SLAB ON GRADE
REPLACEMENT FOR DEMO + NEW
WORK
SCALE: N.T.S.D2
TYPICAL OPNG IN CONCRETE
SLAB/WALL
SCALE: N.T.S.C3 TYPICAL SOG ELECTRICAL BOX
SCALE: N.T.S.B3 TYPICAL SOG CONSTRUCTION JOINT
SCALE: N.T.S.D3 TYPICAL NEW SOG CONSTRUCTION
SCALE: N.T.S.B5 TYPICAL SOG CONTROL JOINT
SCALE: N.T.S.C5 TYPICAL SOG DEPRESSION DETAILS
SEE PLAN
STL COL SEE SCHED
3/8" STIFF ES OF
WEB @ BM FLANGES
3/8" CAP PL (MIN)
OR MATCHING BEAM
FLANGE THICKNESS
SHEAR CONN PER C1/S-005
TYP
TYP
1/4
TYP 3 SIDES
CL CL
CL
PL 3/4x12x1'-0"
(4) LONG-SLOTTED HOLES
PL 3/4x18x2'-2"
(8) LONG-SLOTTED HOLES
PL 3/4x12x1'-4"
(4) LONG-SLOTTED HOLES
BM WEB BM WEB BM WEB
ALL W8 S1
ALL W10
ALL W12
ALL W21
* NO. BOLTS
2 BOLTS
2 BOLTS
3 BOLTS
5 BOLTS
* = NUMBER OF 3/4"Ø BOLTS
S1 S2
S3
** = NUMBER OF 3/4"Ø ADHESIVE ANCHORS
ALL W18 4 BOLTS S38
*** = TYPICAL PLATE UNO ON PLAN PLATE S1 PLATE S2 PLATE S3
TABLE #7 : SURFACE MOUNTED PLATE
CONNECTION SCHEDULE
** NO. ADHESIVE
3/4"Ø ANCHORS
***PLATE
TYPE
BEAM
SIZE 3" 6" 3"
3" 6"
3"
3" 6" 3"
3"
3"
3" 1' - 0" 3"
4" 6"
6" 6"
4"
ALL W16 4 BOLTS S38
CL
PL 3/4x18x2'-6"
(12) LONG-SLOTTED HOLES
BM WEB
PLATE S4
3" 2' - 0" 3"
4" 6"
6" 4"
2L3x3x5/16 X1'-0"
LONG
1/4 0
TYP
3/16
3 SIDES, L3x3
TO BEAM WEB
(TYP)
EXTEND 12" OR HK
FOR EA ADDL #4
(1) #4 x2'-6" @
EA PL
SSL HOLES TO ACCOUNT
FOR TOLERANCE ONLY
ADD #4 BEHIND EA ROW
& COL OF HD STUDS
FACE OF CONC
SINGLE-PL SHEAR CONN
(3/8" PL, 7/8" Ø BOLTS -
SEE SCHEDULE FOR
NUMBER OF BOLTS)EMBEDDED PLATE
CAST INTO CONC
MEMBER
HD STUDS 3/4" Ø
(TYP). SEE PLATE
DETAIL FOR STUD
LENGTH
3 1/2" MAX ECCENTRICITY
5/16
6 5/8" MIN
DRILL & GROUT 3/4"Ø
THREADED ADHESIVE
ANCHS (SEE SCHEDULE
FOR NUMBER OF
ANCHORS)
FACE OF CONC
SINGLE-PL SHEAR CONN
(3/8" PL, 7/8"Ø BOLTS -
SEE SCHEDULE FOR
NUMBER OF BOLTS)
SSL HOLES TO ACCOUNT
FOR TOLERANCE ONLY
5/16
3 1/2" MAX ECCENTRICITY
EMBED
STANDARD SINGLE
PLATE
CONNECTION - (SP)
STANDARD DOUBLE
ANGLE
CONNECTION - (DA)
4"2 1/2"
SINGLE PL CONN
(3/8" PL THICKNESS)
7/8" Ø BOLTS MIN
STL BM
3" SPA TYP
DBL L4x3 1/2x5/16
(MIN ANGLE SIZE)
3/4"Ø MIN
3" SPA TYP
STL GIRDER (SIM
@ STL COL)
2" MIN
MIN
1. REFERENCE ALL STRUCTURAL DRAWINGS FOR ADDITIONAL REQUIREMENTS REGARDING CONNECTIONS.
2. REFERENCE GENERAL NOTES AND DRAWINGS FOR ADDITIONAL INFORMATION REGARDING CONNECTION
DESIGN LOADS. PROVIDE NUMBER OF BOLTS, PLATE AND ANGLE SIZE PER DETAILS AND TABLE.
3. ALL CONNECTIONS SHALL BE STANDARD DOUBLE ANGLE CONNECTIONS, UNLESS OTHERWISE NOTED.
USE OF SINGLE PLATE SHEAR CONNECTIONS MAY BE ALLOWED SUBJECT TO CONTRACTING OFFICER APPROVAL IN LOCATIONS WHERE DBL. ANGLE CONNECTIONS ARE NOT PRACTICAL. CONTRACTOR SHALL
SUBMIT LOCATIONS WHERE SINGLE SHEAR PLATE CONNECTIONS ARE DEEMED NECESSARY TO
CONTRACTING OFFICER FOR APPROVAL PRIOR TO SUBMITTING SHOP DRAWINGS. ALL GIRDERS AND BEAMS FRAMING INTO COLUMNS, PERIMETER MEMBERS AND BEAMS THAT FRAME INTO PERIMETER MEMBERS SHALL HAVE DOUBLE ANGLE CONNECTIONS INCLUDING MOMENT CONNECTION AND BRACING
DETAILS, NO EXCEPTIONS, UNO.
4. MINIMUM NUMBER OF BOLTS FOR STANDARD SINGLE PLATE OR DOUBLE ANGLE CONNECTION AS
FOLLOWS IN ADJACENT TABLE #5.
5. BOLTS IN MOMENT OR BRACING CONNECTIONS SHALL BE FULLY TENSIONED AND THE SURFACES
PREPARED AS "SLIP-CRITICAL".
NOTES:
ALL W8 2 BOLTS
2 BOLTS
3 BOLTS
3 BOLTS
4 BOLTS
2 BOLTS
2 BOLTS
3 BOLTS
3 BOLTS
3 BOLTS
4 BOLTS
6 BOLTS
7 BOLTS
5 BOLTS
ALL W10
ALL W12
ALL W14
ALL W16
ALL W24
ALL W27
ALL W18
ALL W21
4 BOLTS
6 BOLTS
7 BOLTS
5 BOLTS
TABLE #5 : STEEL SHEAR CONNECTIONS
NO BOLTS
(SP)- 7/8"Ø
NO BOLTS
(DA)- 3/4"Ø
BEAM
SIZE
>1 /2
D bm
D co nn
D bm
5/16
>1 /2
D bm
D co nn
D bm
1/4
CL
CL
CL CL
CL
CL
PL 3/4x20x2'-4"
(12) HD STUDS 3/4" Ø X 0'-8"
PL 3/4x12x1'-0"
(4) HD STUDS 3/4" Ø X 0'-8"
PL 3/4x12x1'-8"
(6) HD STUDS 3/4" Ø X 0'-8"
PL 3/4x12x2'-4"
(8) HD STUDS 3/4" Ø X 0'-8"
** H = MIN CONCRETE MEMBER THICKNESS
PL 3/4x12x1'-0"
(4) 3/4" Ø X 0'-6" HD STUDS
PL 3/4x12x1'-8"
(6) 3/4" Ø X 0'-6" HD STUDS
ALL W8
**H=14" **H=9"
P1
ALL W10
ALL W12
ALL W14
ALL W16
ALL W18
ALL W21
2 BOLTS
2 BOLTS
3 BOLTS
3 BOLTS
4 BOLTS
4 BOLTS
5 BOLTS
* = NUMBER OF 7/8" Ø BOLTS
P1 P2 P2 P3 P3 P4
P5 P5 P6 P6
NOT USED
NOT USED
P6
BM WEB
BM WEB
BM WEB BM WEB
BM WEB
*** = TYPICAL PLATE UNO ON PLAN
***PLATE TYPE
PLATE P1 PLATE P2 PLATE P3 PLATE P4
PLATE P5 PLATE P6
TABLE #6 : EMBEDDED PLATE
CONNECTION SCHEDULE
BEAM
SIZE
* NO. BOLTS
7/8"Ø
2" 8" 2"
2" 8"
2"
2" 8" 2"
2" 8"
8" 2"
2" 8" 2"
2" 8"
8" 8"
2"
2" 8" 8" 2"
2" 8"
8" 8"
2"
2" 8" 2"
2" 8"
2"
2" 8" 2"
2" 8"
8" 2"
2 1/2"
INT COL SHOWN EXT
COL SIM
L3x3x1/4 TYP FURN &
INSTALLED BY THE DK
SUPPLIER
#4 x4'-0" DIAG REINF @
EA CORNER OF COL
NOTE:
DECK SUPPLIER MAY SUBMIT ALTERNATE METHODS OF DECK
SUPPORT AT COLUMNS FOR APPROVAL. SUPPORT SHALL
BE CAPABLE OF SUPPORTING CONSTRUCTION LOADS.
EQ
EQ
5/16
TYP
TYP
TYP
SHEET
REFERENCE
NUMBER
SHEET OF
D
ES
IG
N
E D
B Y:
D W
N B
Y:
C
H K
BY
S U
BM
IT
TE
D
B Y:
D
AT
E:
S O
LI
C
IT
A
TI
O
N N
O
C O
N
TR
A C
T N
O
FI
LE
N A
M E:
P
LO
TT
E
D B
Y:
S
IZ
E:
P
LO
T D
A
TE
D
AT
E:
D
ES
C
R
IP
TI
O
N
M
AR
K:
A
PP
R
US ARMY CORPS
OF ENGINEERS
NEW YORK DISTRICT
1 2 3 4 5
D
C
B
A
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
N
EW
Y O
R K ht tp w w w
.n an
.u sa ce .a rm y.
m il ar ch ite ct s
- e ng in ee rs pl an ne rs
W
ES
T
N
AT
IO
N
W
ID
E
BL
VD
C O
LU
M
BU
S, O H
IO
4.
4.
fa x
4.
4.
ht tp w w w
.u rs co rp
.c om
SC
IE
N C
E C
EN
TE
R (F
Y1 1-
B
LD
G
U N
IT
ED
S
TA
TE
S
M
IL
IT
AR
Y
AC
AD
EM
Y W
ES
T
PO
IN
T, N
Y
A R
C H
D
PA
R
K
AV
EN
U
E
SO
U
TH
N
EW
Y O
R K, N Y
3-
2.
7.
fa x
2.
9.
w w w
.s tv in c.
co m
W
2D S
-1 0-
D -0
3/
/2
3:
:2
P
M
S-005
TY
PI
C
AL
D
ET
AI
LS
C
LH
JD
B
SH
A
P R
IL
SCALE: N.T.S.A1
TYPICAL MOMENT CONNECTION DETAIL
AT TOP OF COLUMN
SCALE: N.T.S.A4
TYPICAL SURFACE MOUNTED CONN
PLATE DETAILS AND SCHEDULE
SEE SECTION B3/S-005 FOR DETAILS
SCALE: N.T.S.B2
TYPICAL EMBEDED CONN PLATE
SECTION
SCALE: N.T.S.B3
TYPICAL SURFACE MOUNTED CONN
PLATE SECTION
SCALE: N.T.S.C1
TYPICAL STEEL-TO-STEEL SHEAR
CONNECTIONS
SCALE: N.T.S.C3
TYPICAL EMBEDDED CONN PLATE
DETAILS AND SCHEDULE
SCALE: N.T.S.C5
TYPICAL METAL FLOOR DECK SUPPORT
AT COLUMN
1/2" M
IN
(E) CONC SLAB
GRIND/SAW-CUT (E)
CONC 1/2" AS REQ'D
TO MAINTAIN MIN
THICKNESS OF 1/2"
PROVIDE NON-SHRINK
GROUT FOR SOLID DK BRG
TOOLED JT
RAMP
T/CONC
CEMENTITIOUS
UNDERLAYMENT
18 GA MIN LIGHT GA FRAMING
SUP DK @ 2'-0" OC MAX
LWGT CONC SLAB W/6x6-W1.4xW1.4 ON 0.6"x26 GA MTL FORM DK
SPA VERT STUDS
@ 2'-0" OC MAX
3"
SPA VERT STUDS
@ 2'-0" OC MAX
18 GA MIN LIGHT GA FRAMING
SUP DK @ 2'-0" OC MAX
LWGT CONC SLAB W/6x6-W1.4xW1.4 ON 0.6"x26 GA MTL FORM DK FIELD BEND
CONC CURB FULL PERIM
PROVIDE 3" MIN DK BRG
#3 CONT T & B
#3 DWL @ 24" OC
(E) CONC SLABROUGHEN SURFACE AND
APPLY BONDING AGENT
T/SLAB
PROVIDE 6" MIN CONC CURB FOR
SUPPORT OF EQUIPMENT AND AS
PERIMETER ENCLOSURE FOR FLOOR
PENETRATIONS, SUCH AS VERTICAL
PIPING, DUCTWORK OR CONDUITS
3"
8"
A R
CH
SE
E
SEE PLAN SEE PLAN
8" (MIN) 8" (MIN)
1/
2" C
LR
1/
2" C
LR
(E) CONC ROOF
OR PENTHOUSE
FLOOR SLAB
T/CONC
(E) CONC ROOF
OR PENTHOUSE
FLOOR SLAB
ROUGHEN SURFACE AND
APPLY BONDING AGENT
(2) #4 CONT TOP
T/CURB
SEE S-008 FOR MODIFICATIONS
TO INSTALL NEW FRAMING
ASSOCIATED WITH NEW
OPENINGS.
ADHESIVE WATER STOP
ADHESIVE
WATER STOP
#3 DWL @ 24" OC, DRILL
& EPOXY GROUT INTO
(E) FLOOR SLAB. FOR
CURBS > 12" HEIGHT,
PROVIDE #4 DWLS @ 12"
OC, EF.
VA
R
IE
S
1/2" M
IN
(E) CONC SLAB
GRIND/SAW-CUT (E)
CONC 1/2" AS REQ'D
TO MAINTAIN MIN
THICKNESS OF 1/2"
TOOLED JT
T/CONC
CEMENTITIOUS
UNDERLAYMENT
3' - 4 1/4"
1/4"1 1/2"
BAR 3/8"x3/8"
L2 1/2x2 1/2x1/4
3/8" SST CHECKERED PL (REMOVABLE),
W/ HOLD-DOWN FASTERNERS SPACED
AT 12" O.C. MAX.
COORD W/ ARCH
FOR AREAS TO
MATCH FINISH
FLOOR.
1/4"
1/ 4"
BAND BAR TYP
4 SIDES
1 1/2" DEEP FRP
BAR GRATING
FRP L2 1/2x1 3/4"x1/4, LLH FOUR SIDES.
3/16x1x4 FRP
ANCH STRAPS @
1'-3" OC
D
1" M
IN
(E) CONC SLAB
SEE PLAN FOR EXTENT OF RAMP
SLOPE. REINFORCE NEW SLAB
W/6x6-W2.9xW2.9 WWF.
GRIND/SAW-CUT (E) CONC 1" AS REQ'D TO
MAINTAIN MIN THICKNESS. ROUGHEN SURFACE
TO BOND NEW CONCRETE TO SURFACE. FOR
AREAS > 6" THICKNESS, PLACE COMPACTED
GRANULAR BASE BETWEEN NEW AND EXISTING
SLAB TO MINIMIZE PLACEMENT THICKNESS.
T/CONC
RAMP
1/4"
L3x3x5/16 W/HORIZ
SLOTTED HOLES (13/16"
x2" FOR 3/4"Ø BOLT)
PROVIDE 3/4" Ø EXP
BOLTS @ 2'-0" O.C.
1-1/2" DEEP GALV STEEL GRATING
(REMOVABLE) W/ SERRATED SURFACE.
PROVIDE BOLTED REMOVABLE CLIPS
PER SPECS.
1/4"
1/ 4"
BAND BAR TYP
4 SIDES
1 1/2" GALV STL BAR GRATING,
W/ SERRATED SURFACE
L2 1/2x1 3/4"x1/4, LLH FOUR SIDES.
3/16x1x4 ANCH
TRAPS @ 1'-3"
OC
D
SHEET
REFERENCE
NUMBER
SHEET OF
D
ES
IG
N
E D
B Y:
D W
N B
Y:
C
H K
BY
S U
BM
IT
TE
D
B Y:
D
AT
E:
S O
LI
C
IT
A
TI
O
N N
O
C O
N
TR
A C
T N
O
FI
LE
N A
M E:
P
LO
TT
E
D B
Y:
S
IZ
E:
P
LO
T D
A
TE
D
AT
E:
D
ES
C
R
IP
TI
O
N
M
AR
K:
A
PP
R
US ARMY CORPS
OF ENGINEERS
NEW YORK DISTRICT
1 2 3 4 5
D
C
B
A
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
N
EW
Y O
R K ht tp w w w
.n an
.u sa ce .a rm y.
m il ar ch ite ct s
- e ng in ee rs pl an ne rs
W
ES
T
N
AT
IO
N
W
ID
E
BL
VD
C O
LU
M
BU
S, O H
IO
4.
4.
fa x
4.
4.
ht tp w w w
.u rs co rp
.c om
SC
IE
N C
E C
EN
TE
R (F
Y1 1-
B
LD
G
U N
IT
ED
S
TA
TE
S
M
IL
IT
AR
Y
AC
AD
EM
Y W
ES
T
PO
IN
T, N
Y
A R
C H
D
PA
R
K
AV
EN
U
E
SO
U
TH
N
EW
Y O
R K, N Y
3-
2.
7.
fa x
2.
9.
w w w
.s tv in c.
co m
W
2D S
-1 0-
D -0
3/
/2
3:
:3
P
M
S-006
TY
PI
C
AL
D
ET
AI
LS
C
LH
JD
B
SH
A
P R
IL
SCALE: N.T.S.D1 TYPICAL RAMP : HT > 6"
SCALE: N.T.S.D3
TYPICAL RAISED FLOOR AND RAMP
SLAB
SCALE: N.T.S.D5
TYPICAL NEW CONCRETE CURB AT
ROOF & PENTHOUSE OPENING
SCALE: N.T.S.B1 TYPICAL RAMP : HT< 6"
SCALE: N.T.S.B3
TYPICAL STAINLESS STEEL PLATE
SUPPORT
SCALE: N.T.S.B5 TYPICAL FRP GRATING SUPPORT
SCALE: N.T.S.A1 TYPICAL RAMP OVER SOG
SCALE: N.T.S.A3
TYPICAL GALVANIZED STEEL GRATING
SUPPORT
SCALE: N.T.S.A5
TYPICAL GALVANIZED STEEL GRATING
SUPPORT
PARALLEL TO BEAMS
PERPENDICULAR TO BEAMS
1" C
LR
1"
1"
1" C
LR
C
LR
C
LR
INFILL AS REQ'D
BY ARCH DWGS
8" CMU
L4x4x1/4 BTWN ADJ
BM @ 6'-0" MAX OC
L5x3x1/4x0'-8" LLV ES OF
WALL (TYP @ EA BM)
8" CMU
INFILL BTWN BMS AS
REQ'D PER ARCH DWGS
L5x3x1/4x0'-8" LLV ES OF
WALL (TYP @ EA BM)
STL BM OR (E)
ENCASEMENT
STL BM OR(E)
ENCASEMENT
(N) STL DECK OR (E)
CONC SLAB.
(N) STL DECK OR (E)
CONC SLAB.
#5 @ 48" OC VERT
GROUTED SOLID, UNO
#5 @ 48" OC VERT
GROUTED SOLID, UNO
WHERE ANGLE CONNECTS TO
(E) CONC BEAM ENCASEMENT,
BOLT ANGLE TO CONCRETE
USING (2) 3/8"Ø EXP ANCHORS,
2-1/2" EMBED.
SEE PLAN
3/16
TYP
3/16
TYP
IJ
SEE PLAN
FACE OF (E) CONC
SEE PLAN
FACE OF (E) CONC
L5x5x5/16 CONT DECK SUPPORT
5/8"Ø EXP BOLTS @ 2'-0" OC
(N) 5 1/4" LW CONC SLAB (3
1/4" LW CONC OVER 2" 20
GA COMPOSITE STEEL DECK) ADHESIVE WATERSTOP,
TYP (@ PENTHOUSE)
T/SLAB
(E) STL BM ENCASED IN CONC. SEE SEISMIC
DWGS FOR ZONES OF REMOVAL FOR WALL &
CHORD ELEMENTS.
SEE SEISMIC DWGS FOR (N) DWL REQMT'S @ (E) SLAB
REMOVAL. MAINTAIN (E) SLAB REINFORCING THROUGH
REMOVAL AREA. PROVIDE EPOXY ADHESIVE FOR (N)
SEISMIC DWLS, PER SEISMIC DETAILING.
SEE SEISMIC DETS FOR (E) WALL & CONC
ENCASEMENT REMOVAL @ (N) SEISMIC
WALL DRILL (E) STL MEMBERS FOR
INSTALLATION OF CONTINUOUS REINF IN
WALLS & CHORDS
(N) SEISMIC
WALL
3/ 4"
6", TYP UNO
C
LR
#4 @ 24" OC3'-0"
4"
SEE PLAN
1/4" BT PL
ON PLAN
#4 CONT
AROUND PERIM
OF OPNG
SEE PLAN FOR
BEAM SIZE.
3-12
3-123 16
3 16
TYP
CONNECTING MEMBERSUPPORTING MEMBERBEAM SPACING
1/ 4"
ROOF OPNG
BENT PL 8x3x1/4 LLV x 0'-8"
L5x3 1/2x5/16 LLV
WELD DK TO CHANNELS
& ANGLES
L5x3x1/4 LLV
C6 x 8.2GREATER THAN 6'-0"
CONN MEMBER
SUP MEMBER
4'-1" TO 6'-0"
SIZE & LOC
CONTR FOR
SEE MECH
STL BM OR JST
T/BM
L3x3x1/4 x 0'-4"L3x3x1/4LESS THAN 4'-1" x 0'-6"
1.
2.
DETAIL APPLIES TO TYPICAL ROOF OPENINGS GREATER THAN 12", INCLUDING ALL
ROOF DRAINS; INDICATES ROOF OPENING AS SHOWN ON PLAN.
COORDINATE LOCATION & SIZE OF OPENINGS WITH MECHANICAL CONTRACTOR.
SEE PLAN
3/16
TYP
3/16
TYP
3/16
TYP
FI
EL
D
PROVIDE #5 DWL @ 12" OC, CTR
WITHIN (E) WALL, EXTEND
ANCHORAGE LENGTH INTO (N)
ADHESIVE DWL EMBED INTO (E)
UNO, REINF W/#5 @ 12" OC,
EW, EF
ROUGHEN SURFACE & APPLY
BONDING COMPOUND ACROSS JT,
CHIP KEY 1 1/2"xT/4, UNO
BITUMEN WS, CTR WITHIN
WALL OR SLAB WHERE FINAL
CONSTR IS EXPOSED TO SOIL
SEE SEISMIC DETS FOR
ADD'L SURFACE PREP &
DWLS, WHERE REQ'D
(E) CONC WALL TO REMAIN.
MAINTAIN (E) REINF TO
LAP W/ NEW.
LAP
"T
VE
R
IF
Y
SAWCUT WALL OR SLAB,
FULL DEPTH
SEE SEISMIC DETS FOR
ADD'L SURFACE PREP &
DWLS, WHERE REQ'D
(E) CONC WALL TO REMAIN
CONC REMOVAL
"DRILL" EXPOSED REINF BARS TO
1" BELOW SAWCUT SURFACE.
APPLY CORROSION PROTECTION
TO EXPOSED SURFACES (SIKA
"ARMATEC 110, OR EQUAL).
4'-0"
A
ZYX
W
EXCAVATION
AND SHORING
COMPLETED
EXISTING
CONC. FTG.
UNDISTURBED
3RD SEGMENT
UNDERPINNING
DRY PACKED
EXISTING WALL
ELEVATION A-A
DURING STAGE
INDICATES ORDER OF UNDERPINNING. UNDERPIN BOTH
SECTION WHICH ARE IMMEDIATELY ADJACENT TO COLUMNS
PRIOR TO EXCAVATING THE SECTION BELOW COLUMN.
PLAN LAYOUT OF
UNDERPINNING
PITS
REMOVED PLANK
NEW PLANK
THESE PLANKS
REVOVED WHEN
ADJOINING PIT IS
DUG (SEE BELOW)
STEP FOUR
SECTION Z-Z
TRENCH JACK
SECTION X-X SECTION Y-YSECTION W-W
USE TRENCH JACKS WHERE
TEMPORARY ADDITIONAL
BRACING IS REQUIRED.
IN GENERAL, PLACE 2 SIDE
PLANKS AND WEDGE TWO
END PLANKS BETWEEN
THEM.
CONCRETE
CHUTE
STEP THREE
STEP ONE
STEP TWO
MAX.,TYP.
3 2 1 3 2 3 2 1 3 2
T/CONC Basement 146' - 1"
BASEMENT
146' - 5"
West Basement 146' - 5"
East Basement 146' - 5"
Basement Area B 145' - 6"
Basement 146' - 5"
8" CMU, GROUT SOLID.#4 @ 48" OC,
VERT.
24"x12" DP CONC WALL
FOOTING (CONT).
REINGF W/ (2) #5 CONT.
8"
SHEET
REFERENCE
NUMBER
SHEET OF
D
ES
IG
N
E D
B Y:
D W
N B
Y:
C
H K
BY
S U
BM
IT
TE
D
B Y:
D
AT
E:
S O
LI
C
IT
A
TI
O
N N
O
C O
N
TR
A C
T N
O
FI
LE
N A
M E:
P
LO
TT
E
D B
Y:
S
IZ
E:
P
LO
T D
A
TE
D
AT
E:
D
ES
C
R
IP
TI
O
N
M
AR
K:
A
PP
R
US ARMY CORPS
OF ENGINEERS
NEW YORK DISTRICT
1 2 3 4 5
D
C
B
A
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
N
EW
Y O
R K ht tp w w w
.n an
.u sa ce .a rm y.
m il ar ch ite ct s
- e ng in ee rs pl an ne rs
W
ES
T
N
AT
IO
N
W
ID
E
BL
VD
C O
LU
M
BU
S, O H
IO
4.
4.
fa x
4.
4.
ht tp w w w
.u rs co rp
.c om
SC
IE
N C
E C
EN
TE
R (F
Y1 1-
B
LD
G
U N
IT
ED
S
TA
TE
S
M
IL
IT
AR
Y
AC
AD
EM
Y W
ES
T
PO
IN
T, N
Y
A R
C H
D
PA
R
K
AV
EN
U
E
SO
U
TH
N
EW
Y O
R K, N Y
3-
2.
7.
fa x
2.
9.
w w w
.s tv in c.
co m
W
2D S
-1 0-
D -0
3/
/2
3:
:4
P
M
S-007
TY
PI
C
AL
D
ET
AI
LS
C
LH
JD
B
SH
A
P R
IL
SCALE: N.T.S.C1
TYPICAL MASONRY WALL BRACING
DETAIL
SCALE: N.T.S.D3
TYPICAL SLAB EDGE SUPPORT AT
WALL
SCALE: N.T.S.C2
SLAB MODIFICATION FOR SEISMIC
CHORDS AND WALLS
SCALE: N.T.S.C3
TYPICAL SLAB EDGE &
FLOOR OPENING DETAIL
SCALE: N.T.S.C4 TYPICAL ROOF OPENING
SCALE: N.T.S.B1
TYPICAL CONCRETE WALL EXTENSION
OR OPENING INFILL
SCALE: N.T.S.A1
TYPICAL PARTIAL CONCRETE WALL
REMOVAL
SCALE: N.T.S.A3
TYPICAL WALL AND COLUMN
FOUNDATION UNDERPINNING
SCALE: N.T.S.A5 TYPICAL MASONRY WALL FOOTING
13. FORMWORK:
A. IF THROUGH THICKNESS FORM-TIES ARE USED SUCH FORM-TIES SHALL BE
CONSIDERED CONSTRUCTION AID AND ARE TO BE PROVIDED IN ADDITION
TO OTHER ITEMS SHOWN ON DRAWINGS SUCH AS THE TYPICAL MASONRY
ANCHORAGE.
B. WHERE THROUGH THICKNESS FORM -TIES ARE USED CONTRACTOR SHALL
VERIFY THAT APPLIED FORM PRESSURES ARE SUCH THAT FORMS AND EXISTING
MATERIALS ARE CAPABLE TO SPAN BETWEEN TIE LOCATIONS, SEE NOTE D, TYP.
C. WHERE FORM-TIES ARE NOT USE CONTRACTOR SHALL VERIFY THAT FORMWORK AND
EXISTING WALLS ARE CAPABLE OF SUSTAINING REQUIRED FORMWORK PRESSURES,
INCLUDING ACCOUNTING FOR ACTUAL CONCRETE PLACEMENT RATES, SEE NOTE D, TYP.
D. FOR PURPOSE OF CHECKING EXISTING WALLS FOR FORMWORK PRESSURES,
STRUCTURAL PROPERTIES FOR EXISTING MASONRY WALLS SHALL BE TAKEN PER
FEMA 356 AS FOLLOWS:
- COMPRESSION: 900 PSI
- SHEAR: 27 PSI
- TENSION: 20 PSI
14. SHORING:
A. WHEN ZONES OF EXISTING SLAB ARE REMOVED REGIONS TO REMAIN SHALL BE
SUPPORTED VERTICALLY BY SHORING AT A MAX SPACING OF 8 FT ON CENTERS. SUCH
SHORING SHALL ALSO BE USED TO SUPPORT THE FULL WET LOAD OF CONCRTE PLACED IN THESE
REGIONS.
B. SHORING SHALL BE MAINTAINED UNTIL CONCRETE REACHES FULL 28 DAYS STRENGTH.
C. CONTRACTOR SHALL VERIFY ADEQUATE VERTICAL EXTENTS TO PROVIDE SUPPORT FOR
ALL SHORING.
D. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LAYOUT, DESIGN, SEQUENCING AND
MAINTENANCE OF ALL SHORING AND BRACING DURING THE PROGRESS OF THE WORK. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF THE SHORING AND BRACING UPON
COMPLETION OF THE WORK.
15. CONSTRUCTION SEQUENCING.
A. CONSTRUCTION OF THE NEW REINFORCED CONCRETE WALLS SHALL BE FROM THE
FOUNDATION LEVEL TO THE TOP OF THE STRUCTURE.
B. WORK SHALL BE ACCOMPLISHED SUCH THAT, FROM FOUNDATION LEVEL UP TO THE SECOND FLOOR, SEISMIC WALLS AND COLLECTOR/CHORDS ARE COMPLETE ON A FLOOR BY FLOOR BASIS.
16. DRILLED DOWELS IN CONCRETE:
A. ALL REINFORCING DOWELS SHOWN ON DRAWINGS TO BE INSTALLED IN EXISTING CONCRETE
SHALL BE SET WITH HILTI RE 500-SD ADHESIVE ANCHOR SYSTEM OR EQUAL APPROVED BY THE
CONTACTING OFFICER.
B. HOLES SHALL BE INSTALLED AS RECOMMENDED BY THE MANUFACTURER, CARE SHALL BE
EXERCISED TO AVOID DAMAGING EXISTING REINFORCING OR EMBEDDED STEEL UNLESS OTHERWISE
AUTHORIZED BY THE CONTRACTING OFFICER OR SHOWN ON DRAWINGS. HOLES SHALL BE
CLEANED AS RECOMMENDED BY THE MANUFACTURER PRIOR TO SETTING.
C. UNLESS OTHERWISE SHOWN ON DRAWINGS DOWEL EMBEDMENT
AND PROOF LOAD SHALL BE AS FOLLOWS:
DOWEL SIZE DOWEL TENSION
EMBEDMENT PROOF LOAD
(IN) (LBS)
#4 8 6,000 #5 10 9,000 #6 12 13,000 #7 14 18,000 #8 16 24,000 #9 20 30,000 #10 24 38,000 #11 29 45,000
D. TEN PERCENT (10%) OR A MINIMUM OF 5 OF EACH DIAMETER DOWEL SHALL BE PROOF-TESTED BY AN INDEPENDENT TESTING LAB. A SUCCESSFUL TEST IS DEFINED AS DEVELOPMENT OF THE PROOF
LOAD DOWEL FAILS ALL DOWELS OF THE SAME SIZE AND INSTALLED ON THE SAME DATE
SHALL BE TESTED. THE TENSION TEST LOAD MAY BE APPLIED BY ANY MEANS THAT WILL TEST BOND
STRENGTH OF THE DOWEL WITHOUT DAMAGING THE SURFACE OF THE CONCRETE AND THAT WILL
EFFECTIVELY ALLOW MEASUREMENT OF THE TENSION IN THE DOWEL.
17. THE STRUCTURAL DRAWINGS SHOW ONLY THE BASIC STRUCTURE, REFER TO ARCHITECTURAL MECHANICAL, ELECTRICAL, PLUMBING AND OTHER DOCUMENTS FOR ITEMS WHICH REQUIRE COORDINATION DURING CONSTRUCTION. ALL PIPING, CONDUIT AND OTHER REQUIRED PENETRATIONS OF THE NEW SEISMIC WALLS AND/OR CHORDS AND COLLECTORS AS WELL AS SHALL BE DETERMINED AND VERIFIED BEFORE
COMMENCING FABRICATION AND/OR CONSTRUCTION.
ALL CONFLICTS AND AMBIGUITIES SHALL BE BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER AND SHALL BE RESOLVED AS DIRECTED BY THE CONTRACTING OFFICER BEFORE COMMENCING
FABRICATION AND/OR CONSTRUCTION.
18. ALL REQUIRED DETAILS AND/OR DIMENSIONS NOT SHOWN SPECIFICALLY ON DRAWINGS SHALL BE OF SIMILAR CHARACTER AS SHOWN ON DRAWINGS FOR SIMILAR CONDITIONS, AND SHALL BE REVIEWED AND APPROVED BY
THE CONTRACTING OFFICER PRIOR TO COMMENCING FABRICATION AND/OR CONSTRUCTION.
19. WHERE "HILTI RE 500 OR EQUAL" IS SHOWN ON DRAWINGS, PRODUCTS PER NOTE 2 ON S-030 SHALL BE USED.
20. WHERE "LENTON OR APPROVED EQUAL" IS SHOWN ON DRAWINGS, PRODUCTS PER NOTES 3 AND 4 ON S-030
SHALL BE USED.
SEISMIC GENERAL NOTES:
1. FOR GENERAL NOTES, ABBREVIATIONS AND LEGENDS SEE DWG S-001 THROUGH S-004.
2. ADHESIVE ANCHORAGE SYSTEM FOR DRILLED REINFORCING ANCHORS INSTALLED
INTO EXISTING CONCRETE AND/OR SOLID MASONRY WALLS SHALL BE ONE OF THE FOLLOWING
PRODUCTS: HILTI RE 500-SD, ADHESIVE TECHNOLOGY ULTRABOND A1 OR UNITEX PRO-POXY 400, INSTALLED PER MANUFACTURERS INSTRUCTIONS AND AS SHOWN ON DRAWINGS.
3. REINFORCING SHOWN FOR COLLECTORS OR CHORDS SHALL BE CONTINUOUS FOR
THE EXTENT SHOWN ON DRAWINGS, BARS SHALL BE SPLICED AS NECESSARY FOR
INSTALLATION WITH ONE OF THE FOLLOWING PRODUCTS: LENTON THREADED BAR COUPLERS BY
ERICO, INC., THREADED SPLICING SYSTEMS BY DAYTON SUPERIOR OR DYWIDAG THREADBAR
REINFORCING SYSTEM BY DYWIDAG, WHEN SELECTING BAR COUPLERS DIMENSIONS OF THE
COUPLERS SHALL BE CONSIDERED TO AVOID REBAR CONGESTION. BAR COUPLER LOCATION
SHALL BE STAGGERED SO THAT NO MORE THAN 50% OF BARS ARE SPLICED AT ONE LOCATION,
STAGGER SHALL BE 4'-0". ALL BARS SHALL PASS THROUGH EXISTING BEAMS, GIRDERS OR
COLUMNS AS SHOWN. DRILL HOLES IN EXISTING BEAMS, GIRDERS OR COLUMNS TO ALLOW
REINFORCING TO PASS THROUGH. DO NOT CUT OR DRILL THROUGH BEAM, GIRDER OR COLUMN
FLANGES UNLESS OTHERWISE SHOWN ON DRAWINGS, TYP.
4. BOUNDARY REINFORCING SHOWN FOR NEW CONCRETE WALLS SHALL BE CONTINUOUS,
BARS SHALL BE SPLICED AS NECESSARY FOR INSTALLATION ONE OF THE FOLLOWING
PRODUCTS: LENTON THREADED BAR COUPLERS BY ERICO, INC., THREADED SPLICING SYSTEMS
BY DAYTON SUPERIOR OR DYWIDAG THREADBAR REINFORCING SYSTEM BY DYWIDAG, WHEN
SELECTING BAR COUPLERS DIMENSIONS OF THE COUPLERS SHALL BE CONSIDERED TO AVOID
REBAR CONGESTION. BAR COUPLER LOCATION SHALL BE AT MID FLOOR HEIGHT OR MID
SPANDREL SPAN AND SHALL BE STAGGERED SO THAT NO MORE THAN 50% OF BARS ARE SPLICED
AT ONE LOCATION STAGGER SHALL BE 30 IN MIN. ALL BOUNDARY BARS SHALL PASS
THROUGH EXISTING BEAMS, GIRDERS OR COLUMNS AS SHOWN. DRILL HOLES IN EXISTING
BEAMS, GIRDERS OR COLUMNS TO ALLOW REINFORCING TO PASS THROUGH, ALL BOUNDARY
REINFORCING SHALL COMPLY WITH THE REQUIREMENTS OF ASTM A706, TYP.
5. DEMOLITION AS REQUIRED FOR PERFORMANCE OF WORK IS INCLUDED WITHIN THE SCOPE
OF WORK DEFINED BY THE CONTRACT DOCUMENTS. DEMOLITION DRAWINGS ARE PROVIDED
INDICATINGAREAS OF REQUIRED DEMOLITION AND, DUE TO THE COMPLEXITY OF THE PROJECT AND THE POTENTIAL FOR CONTRACTOR MEANS AND METHODS TO POTENTIALLY AFFECT THE SCOPE OF
REQUIRED DEMOLITION, AREAS BEYOND THOSE INDICATED ON THE DEMOLITION DRAWINGS
SHOULD BE EXPECTED TO OCCUR. SUCH AREAS ARE WITHIN THE SCOPE OF REQUIRED WORK
DEFINED BY THE CONTRACT DOCUMENTS AND SHALL BE PERFORMED INCLUDING COMPLIANCE
WITH ALL CONTRACT REQUIREMENTS FOR THE CONTRACTOR TO PROVIDE SHORING AND OR
BRACING FOR STABILIZATION OF STRUCTURE DURING CONSTRUCTION OPERATIONS.
DEMOLISH (E) CONCRETE AS REQUIRED TO ALLOW INSTALLATION OF NEW CONCRETE
WALLS AND COLLECTORS/CHORDS, PRESERVE, DO NOT CUT, (E) CONCRETE SLAB
REINFORCING, CONTRACTOR TO SELECT DEMO MEANS AND METHODS SUCH AS TO MINIMIZE
DAMAGE TO (E) REINFORCING, TYPICAL AT ALL NEW WALLS AND COLLECTORS/CHORDS, SEE
NOTES FOR SHORING REQUIREMENTS.
6. PROVIDE SPECIAL INSPECTION PER SPECIFICATION SECTION 01 45 35 "SPECIAL
INSPECTION FOR SEISMIC -RESISTING SYSTEMS" FOR ALL NEW REINFORCED CONCRETE
SEISMIC WALLS, CHORDS/COLLECTORS INCLUDING PLACEMENT OF CONCRETE,
REINFORCING, WELDING OF DEFORMED BAR ANCHORS, WELDING OF HEADED STUDS,
DRILLING THROUGH EXISTING STEEL MEMBERS AND INSTALLATION OF DRILLED
ANCHORS INTO EXISTING MASONRY OR CONCRETE.
7. FOR ANCHORAGE OF EXISTING UNREINFORCED MASONRY WALLS WITH VOIDS TO NEW
REINFORCED CONCRETE SEISMIC WALLS SEE DETAIL X ON DRAWING S-XXX, UNLESS NOTED
OTHERWISE ON DRAWINGS, FOR BID PURPOSE ASSUME 15% OF (E) MASONRY WALL SURFACE TO
REQUIRE ANCHORAGE PER DETAIL X ON S-XXX, TYP.
8. COORDINATE TOP OF NEW WALLS, DIMENSIONS AND LOCATIONS OF OPENINGS IN THE NEW
REINFORCED CONCRETE SEISMIC WALLS WITH ARCHITECTURAL AND MECHANICAL DRAWINGS.
9. FOUNDATION CONDITIONS SHOWN ARE BASED ON INFORMATION AVAILABLE FROM EXISTING
BUILDINGS DESIGN DRAWINGS, ACTUAL CONDITIONS MAY VARY. CONTRACTOR SHALL FIELD
VERIFY EXISTING CONDITIONS AND DISCREPANCIES SHALL BE REPORTED TO THE CONTRACTING
OFFICER PRIOR TO START OF ANY CONSTRUCTION ACTIVITIES.
10. PROVIDE TEMPORARY SHORING, BRACING, SHEETING, UNDERPINNING AS AN INTEGRAL PART OF
THE INSTALLATION OF NEW FOUNDATIONS AND AS NECESSARY TO PROTECT EXISTING AND NEW
ADJACENT STRUCTURES, UTILITIES, GRADES, PAVEMENTS, SLABS AND OTHER FEATURES.
SUBMIT DRAWINGS AND CALCULATIONS, FOR REVIEW AND APPROVAL BY THE CONTRACTING
OFFICER, CERTIFIED BY A REGISTERED PROFESSIONAL ENGINEER, DESCRIBING THE METHODS
FOR SHORING, SHEETING, BRACING AND UNDERPINNING. SEE SPECIFICATIONS AND OTHER
NOTES ON DRAWINGS FOR ADDITIONAL REQUIREMENTS INCLUDING PRECONSTRUCTION
SURVEY AND MONITORING OF THE BUILDING DURING CONSTRUCTION.
11. UNDER ALL NEW FOUNDATIONS REMOVE ALL MATERIAL DISTURBED BY CONSTRUCTION
OPERATIONS AND BACKFILL WITH STRUCTURAL CONCRETE MATCHING PROPERTIES OF NEW
FOUNDATION CONCRETE, SEE GEOTECHNICAL REPORT AND SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
12. ANY OVEREXCAVATION SHALL BE RESTORED TO REQUIRED ELEVATION USING ENGINEERED
COMPACTED FILL OR CONCRETE BACKFILL AS DIRECTED BY THE CONTRACTING OFFICER.
A.B.
ADD.
ALT.
B.
BLK.
BM.
B.O.S.
BRG.
CJ
CL
CLR.
COL
CONT.
CONTR. JT.
CP
CP
DBL
DIA
DWG.
EA.
EF
EL, ELEV
ES
EXP. JT.
EXT.
FL
FS
FLR
GA
GR.
HDR.
HK.
HORIZ.
HSB
HSS
INFO
LLH
LLV
MAX.
M.B.
MIN.
MISC.
M.S.
NS
NIC
NTS
O.C.
OH
OWJ
P , PL
PSF
PVMT.
REINF.
S.A.D.
S.C.D.
S.M.D.
S.P.D.
SIM.
SL
SPL
STD
STL
STIFF
STR
SUPP.
SYM.
T.
T&B
THR'D
T.O.S.
TYP.
U.N.O.
VERT., V.
WWF
ABBREVIATIONS
ANCHOR BOLT
ADDITIONAL
ALTERNATE
BOTTOM
BLOCK
BEAM
BOTTOM OF STEEL
BEARING
CONSTRUCTION JOINT
CENTER LINE
CLEAR
COLUMN
CONTINUOUS
CONTROL JOINT
COMPLETE PENETRATION
COLLAPSE PREVENTION
DOUBLE
DIAMETER
DRAWING
EACH
EACH FACE
ELEVATION
EACH SIDE
EXPANSION JOINT
EXTERIOR
FLANGE
FAR SIDE
FLOOR
GAUGE
GRADE
HEADER
HOOK
HORIZONTAL
HIGH STRENGTH BOLT
HOLLOW STRUCTURAL SHAPE
INFORMATION
LONG LEG HORIZONTAL
LONG LEG VERTICAL
MAXIMUM
MACHINE BOLT
MINIMUM
MISCELLANEOUS
MILD STEEL
NEAR SIDE
NOT IN CONTRACT
NOT TO SCALE
ON CENTER
OPPOSITE HAND
OPEN WEB STEEL JOIST
PLATE
POUND PER SQUARE FOOT
PAVEMENT
REINFORCEMENT
SEE ARCHITECTURAL DRAWING
SEE CIVIL DRAWINGS
SEE MECHANICAL DRAWINGS
SEE PLUMBING DRAWINGS
SIMILAR
SLOPE
SPLICE
STANDARD
STEEL
STIFFENER
STRUCTURAL
SUPPORT
SYMMETRICAL
TOP
TOP AND BOTTOM
THREADED
TOP OF STEEL
TYPICAL
UNLESS NOTED OTHERWISE
VERTICAL
WELDED WIRE FABRIC
A
B
D
C
E
SHEET
REFERENCE
NUMBER
SHEET OF
D
ES
IG
N
E D
B Y:
D W
N B
Y:
C
H K
BY
S U
BM
IT
TE
D
B Y:
D
AT
E:
S O
LI
C
IT
A
TI
O
N N
O
C O
N
TR
A C
T N
O
FI
LE
N A
M E:
P
LO
TT
E
D B
Y:
S
IZ
E:
P
LO
T D
A
TE
D
AT
E:
D
ES
C
R
IP
TI
O
N
M
AR
K:
A
PP
R
US ARMY CORPS
OF ENGINEERS
NEW YORK DISTRICT
1 2 3 4 5
D
C
B
A
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
N
EW
Y O
R K ht tp w w w
.n an
.u sa ce .a rm y.
m il ar ch ite ct s
- e ng in ee rs pl an ne rs
W
ES
T
N
AT
IO
N
W
ID
E
BL
VD
C O
LU
M
BU
S, O H
IO
4.
4.
fa x
4.
4.
ht tp w w w
.u rs co rp
.c om
SC
IE
N C
E C
EN
TE
R (F
Y1 1-
B
LD
G
U N
IT
ED
S
TA
TE
S
M
IL
IT
AR
Y
AC
AD
EM
Y W
ES
T
PO
IN
T, N
Y
A R
C H
D
PA
R
K
AV
EN
U
E
SO
U
TH
N
EW
Y O
R K, N Y
3-
2.
7.
fa x
2.
9.
w w w
.s tv in c.
co m
W
2D S
-1 0-
D -0
A
P R
IL
3/
/2
3:
:5
P
M
S-030
SE
IS
M
IC
G
EN
ER
AL
N O
TE
S
D es ig ne r
A ut ho r
C he ck er
PLAN
NORTH
D
D/3
D/3
TYPICAL WALL OPENING TRIM
REINFORCING
SEE NOTES
TYP
ADD 2#5 TRIM BARS,
TYP UNO
TYPICAL WALL OPENING TRIM
REINFORCING
ADD 2#5 TRIM BARS,
TYP UNO
SEE NOTES
TYP
PROVIDE
STANDARD HOOK
WHERE EXTENSION
IS NOT POSSIBLE,
TYPSE
E
NO
TE
S
TY
P
3/4"CLR
1'-2"
3/4"CLR
1'-2"
FOR SPACING
SEE ELEVATIONS,
TYP
VERTICAL WALL SECTION
SEE ELEVATIONS
FOR REINFORCING,
TYP
HORIZONTAL WALL SECTION
TOP OF
WALL/SPANDRELS,
TYP
2"CLR AT TOP
OF WALL, TYP
3/4"CLR AT SPANDREL,
TYP
FOR SPACING
SEE ELEVATIONS,
TYP
#4 TIES, SEE
DETAILS FOR
NUMBER AND
SPACING, TYP
SEE ELEVATIONS
FOR REINFORCING,
TYP
(N) SEISMIC
WALL, TYP
(N) SEISMIC
WALL, TYP
3/4" CLR,
TYP
6" TYP
UNO.
#4 TIES , SPACING
TO MATCH VERTICAL
WALL REINFORCING,
TYP UNO. 2"
C
LR
3/4"CLR 3/4"CLR
10" 10"
FOR SPACING
SEE ELEVATIONS,
TYP
VERTICAL WALL SECTION
SEE ELEVATIONS
FOR REINFORCING,
TYP
HORIZONTAL WALL SECTION
#4 TIES, SEE
DETAILS FOR
NUMBER AND
SPACING, TYP
SEE ELEVATIONS
FOR REINFORCING,
TYP
FOR SPACING
SEE ELEVATIONS,
TYP
TOP OF
WALL
BOUNDARY ZONE,
SEE DETAILS FOR
INFO, TYP
(N)SEISMIC
WALL, TYP (N)SEISMIC
WALL, TYP
#4 TIES, SPACING
TO MATCH VERTICAL
WALL REINFORCING,
TYP UNO.
FIELD REBAR
#5@12 CC
EF, EW, TYP
FIELD
REBAR
#5@12 CC
EF, EW,TYP
TOP OF CONCRETE
FLOOR
TOP OF CONCRETE
FLOOR
TOP OF CONCRETE
FLOOR
BOUNDARY REINFORCING
SEE WALL ELEVATIONS, TYP
BOUNDARY
REINFORCING
SEE WALL
ELEVATIONS, TYP
FIELD REBAR
#5@12 CC
EF, EW, TYP
FIELD REBAR
#5@12 CC
EF, EW, TYP
FOR DEVELOPMENT
LENGTH SEE GENERAL
NOTES, OR USE LENTON
BAR TERMINATORS AS
REQUIRED, TYP
FIELD REBAR
#5@12 CC
EF, EW,
TYP
BOUNDARY REINFORCING SHOWN FOR NEW
CONCRETE WALLS SHALL BE CONTINUOUS,
BARS SHALL BE SPLICED AS NECESSARY FOR
INSTALLATION WITH LENTON THREADED BAR
COUPLERS. BAR COUPLER LOCATION SHALL BE AT
MID FLOOR HEIGHT OR MID SPANDREL SPAN AND
SHALL BE STAGGERED SO THAT NO MORE THAN 50%
OF BARS ARE SPLICED AT ONE LOCATION STAGGER
SHALL BE 30 IN MIN. ALL BOUNDARY BARS SHALL
PASS THROUGH EXISTING BEAMS, GIRDERS OR
COLUMNS AS SHOWN. DRILL HOLES IN EXISTING
BEAMS, GIRDERS OR COLUMNS TO ALLOW
REINFORCING TO PASS THROUGH, ALL BOUNDARY
REINFORCING SHALL COMPLY WITH THE
REQUIREMENTS OF ASTM A706, TYP.
AT OFFSET BOUNDARY BARS WHERE SPLICING
USING LENTON THREADED BAR COUPLERS IS NOT
POSSIBLE AND THERE IS INSUFFICIENT SPACE FOR
BAR DEVELOPMENT PER TABLE X ON S-XXX,
PROVIDE LENTON TERMINATORS OR APPROVED
EQUAL AT ALL BAR ENDS, TYP
SPLICE BOUNDARY
BARS WITH
LENTON THREADED
BAR COUPLERS
OR APPROVED
EQUAL, TYP
NEW FOUNDATION
SEE NOTE 16 ON
DWG S-030
TYPICAL SEISMIC
WALL
CORNER DETAIL
TYPICAL SEISMIC
WALL
INTERSECTION
FOR SPACING
SEE ELEVATIONS,
TYP
SEE ELEVATIONS
FOR REINFORCING,
TYP
3/4" CLR
TYP
FOR BOUNDARY
REINFORCING,
INCLUDING
ADDITIONAL TIES
REQUIRED, SEE
ELEVATIONS,
SECTIONS AND
DETAILS, TYP
90° STANDARD
HOOKS, TYP
3/4" CLR
TYP
FOR SPACING
SEE ELEVATIONS,
TYP
90° STANDARD
HOOKS, TYP
SEE ELEVATIONS
TYP
FOR REINFORCING,
FOR BOUNDARY
REINFORCING,
INCLUDING
ADDITIONAL TIES
REQUIRED, SEE
ELEVATIONS,
SECTIONS AND
DETAILS, TYP
2'-0"
TYP
2'-0"
TYP
1" T
YP
1" T
YP
SEE ELEVATIONS FOR
REINFORCING, TYP
ADD 2#5 AT
ARCHED WINDOWS,
TYP
ADD #4@12 TIES
AT ARCHED WINDOWS,
TYP
(N) SEISMIC
WALL
D/3 D/3 D/3
1/
2"
1'-0
U
NO
6"
FOR SPLICE
SEE GENERAL
NOTES, TYP
NOTE:
USE LENTON FORMSAVERS/
COUPLERS FOR SPLICING
WHERE REQUIRED.
A
B
D
C
E
INTERMITTENT KEY,
FORM WITH 2x, 6" LONG
@12" CC, TYP
NOTE:
USE LENTON FORMSAVERS/
COUPLERS FOR SPLICING
WHERE REQUIRED.
SHEET
REFERENCE
NUMBER
SHEET OF
D
ES
IG
N
E D
B Y:
D W
N B
Y:
C
H K
BY
S U
BM
IT
TE
D
B Y:
D
AT
E:
S O
LI
C
IT
A
TI
O
N N
O
C O
N
TR
A C
T N
O
FI
LE
N A
M E:
P
LO
TT
E
D B
Y:
S
IZ
E:
P
LO
T D
A
TE
D
AT
E:
D
ES
C
R
IP
TI
O
N
M
AR
K:
A
PP
R
US ARMY CORPS
OF ENGINEERS
NEW YORK DISTRICT
1 2 3 4 5
D
C
B
A
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
N
EW
Y O
R K ht tp w w w
.n an
.u sa ce .a rm y.
m il ar ch ite ct s
- e ng in ee rs pl an ne rs
W
ES
T
N
AT
IO
N
W
ID
E
BL
VD
C O
LU
M
BU
S, O H
IO
4.
4.
fa x
4.
4.
ht tp w w w
.u rs co rp
.c om
SC
IE
N C
E C
EN
TE
R (F
Y1 1-
B
LD
G
U N
IT
ED
S
TA
TE
S
M
IL
IT
AR
Y
AC
AD
EM
Y W
ES
T
PO
IN
T, N
Y
A R
C H
D
PA
R
K
AV
EN
U
E
SO
U
TH
N
EW
Y O
R K, N Y
3-
2.
7.
fa x
2.
9.
w w w
.s tv in c.
co m
W
2D S
-1 0-
D -0
A
P R
IL
3/
/2
3:
:5
P
M
S-031
SE
IS
M
IC
T
YP
IC
AL
D
ET
AI
LS
S H
T
D es ig ne r
A ut ho r
C he ck er
0 1/2 1 2
SCALE: 1/2" = 1'-0"1 TYPICAL WALL REINF. ARRANGEMENT 1
0 1/2 1 2
SCALE: 1/2" = 1'-0"2 TYPICAL WALL REINF. ARRANGEMENT 2
0 1/2 1 2
SCALE: 1/4" = 1'-0"3 TYPICAL WALL REINFORCING
PLAN
NORTH
0 1/2 1 2
SCALE: 1/2" = 1'-0"4 TYPICAL WALL INTERSECTION
0 1/2 1 2
SCALE: 1/4" = 1'-0"5 DETAIL AT ARCHED WINDOWS/DOORS
0 1/2 1 2
SCALE: 1/8" = 1'-0"6
TYPICAL HORIZ WALL
CONSTR. JOINT
0 1/2 1 2
SCALE: 3/4" = 1'-0"7
TYPICAL VERT. WALL
CONSTR. JOINT
0 1/2 1 2
SCALE: 1/2" = 1'-0"8 TYP WALL OPENING TRIM REINFORCING
2" MAX
9" M
IN
EXISTING MASONRY
WALL, TYP
NEW REINFORCED
CONCRETE SEISMIC
WALL, TYP
FINISHED FLOOR
NEW REINFORCED
CONCRETE
CHORD/COLLECTOR,
TYP
CORE DRILL HOLES
IN (E)SLAB AS REQU'D
BY ADHESIVE ANCHOR.
SYSTEM MANUFACTURER,
TYP
#4@12"
INSTALL IN (E)WALL
PER GENERAL
NOTES, TYP
(E) SLAB REINF.
SEE GEN. NOTE 5, TYP
#4@12" CC
W/ 8" EMBED,
TYP.
NOTE:
FOR ADDITIONAL INFO NOT SHOWN
SEE OTHER DETAILS ON TYPICAL
DETAILS SHEETS, TYP
3" 3" 2"
DD
D
D
D
3" 3"
LENTON
COUPLERS,
TYP
KEY, FORM WITH 3x, TYP
2"MAX
.5
(E) MASONRY
WALL, TYP
SCREEN TUBE IN
1"DIA DRILLED HOLE,
TYP
MASONRY WALL WITH VOIDS ANCHORAGE NOTES:
(N) CONCRETE
SHEAR WALL, TYP
1. THREADED RODS SHALL COMPLY WITH THE
REQUIREMENTS OF ASTM A 307 PREBENT AT
ANGLE OF 22 1/2 DEGREES, SUPPLIED WITH
NUTS CONFORMING TO ASTM A 564.
2. ADHESIVE SHALL BE ONE OF THE FOLLOWING
HILTI-HY 20, SIMPSON SET OR IRW RAMSET EPCON
CERAMIC 6, INSTALLED IN WIRE MESH GALVANIZED
SCREEN TUBES.
3. CONTINUOUS SPECIAL INSPECTION MUST BE DONE
IN ACCORDANCE WITH SECTION 1704.5 OF THE IBC.
4. DIRECT-TENSION TESTS AND CALIBRATED TORQUE
WRENCH TESTS MUST BE DONE IN ACCORDANCE
WITH SECTION 107.4 OF THE IEBC.
5. FOR SPACING OF THE MASONRY ANCHORS SEE
PLANS, SECTIONS AND DETAILS.
3/4" DIAM
THREADED
ROD, TYP
9" MIN
SEE NOTE 5
ON S-030SEE NOTE 5
ON S-030
H H
(E) CONCRETE
FLOOR SLAB,
TYP
(E) REINFORCING,
SEE NOTE 5
ON S-030, TYP
(E) MASONRY
WALL, TYP
NEW CHORD/COLLECTOR
REINFORCING SEE
NOTE 3, ON S-030, TYP
H=1'-4" TYPICAL UNO.
NEW SEISMIC
WALL, TYP
#4@12", STIRRUPS,
TYP
3#8 TOP&BOTT.
CHORD/COLLECTOR
REINF., TYP UNO
3#8 TOP&BOTT.
CHORD/COLLECTOR
REINF., TYP UNO
W W
W=1'-6" TYPICAL UNO.
T
D 3D
WALL CL,
TYP
D MAX = T/3 OR 2"
WHICHEVER IS
SMALLER
D
(N) SEISMIC
CHORD, TYP
#4@12"
STIRRUPS,
TYP
STL PIPE SLEEVE
D=5"MAX OD
(N) SEISMIC
CHORD, TYPSTL PIPE
SLEEVE
D=5"MAX OD
6" MIN
ADD #4
STIRRUP,
TYP
(E) MASONRY
WALL, TYP
(N) CONCRETE
SHEAR WALL, TYP
A
B
D
C
E
2" MAX, TYPNEW REINFORCED
CONCRETE
SEISMIC WALL, TYP
(E) MASONRY WALL,
TYP
#4@4'-0" CC EW,
DRILL HOLES IN (E)
MASONRY WALL AND
INSTALL WITH HILTI
RE 500 AS RECOMMENDED
BY MANUFACTURER, TYP
UNO.
S3 S4
S S2 S1
DEFORMED BAR/ASTM A706 ANCHOR NOTES:
(E) STEEL
BEAM OR
COLUMN, TYP
1. ALL DEFORMED BAR ANCHORS SHALL BE 5/8" DIAMETER
(#5) UNO, AND IN ACCORDANCE WITH ASTM A-496 WITH
MIN TENSILE STRENGTH OF 80,000 PSI AND MIN YIELD
STRENGTH OF 70,000 PSI. ASTM A706 REINF. SHALL BE #5 UNO.
2. WELDING SHALL BE BY ELECTRIC ARC PROCESS AND BE
CAPABLE OF DEVELOPING FULL CAPACITY OF THE DEFORMED
BAR ANCHOR OR ASTM A706 REINFORCING..
3. PREPARE (E) STEEL PER DEFORMED BAR ANCHOR
MANUFACTURERS RECOMMENDATIONS BEFORE WELDING.
4. WELDING AND INSPECTION SHALL CONFORM TO AWS D.1.1
5. UNLESS OTHERWISE NOTED, DEFORMED BAR ANCHOR/ASTM A706
REINF. WELDING SHALL EXTEND FULL LENGTH BETWEEN BEAM/COLUMN
INTERSECTIONS AT SPACING (S, S1 THROUGH S4) AS INDICATED
ON DRAWINGS.
(N) DEFORMED BAR
ANCHOR OR ASTM
A706 REBAR, TYP
(N) DEFORMED BAR
ANCHOR OR ASTM
A706 REBAR, TYP
SHEET
REFERENCE
NUMBER
SHEET OF
D
ES
IG
N
E D
B Y:
D W
N B
Y:
C
H K
BY
S U
BM
IT
TE
D
B Y:
D
AT
E:
S O
LI
C
IT
A
TI
O
N N
O
C O
N
TR
A C
T N
O
FI
LE
N A
M E:
P
LO
TT
E
D B
Y:
S
IZ
E:
P
LO
T D
A
TE
D
AT
E:
D
ES
C
R
IP
TI
O
N
M
AR
K:
A
PP
R
US ARMY CORPS
OF ENGINEERS
NEW YORK DISTRICT
1 2 3 4 5
D
C
B
A
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
N
EW
Y O
R K ht tp w w w
.n an
.u sa ce .a rm y.
m il ar ch ite ct s
- e ng in ee rs pl an ne rs
W
ES
T
N
AT
IO
N
W
ID
E
BL
VD
C O
LU
M
BU
S, O H
IO
4.
4.
fa x
4.
4.
ht tp w w w
.u rs co rp
.c om
SC
IE
N C
E C
EN
TE
R (F
Y1 1-
B
LD
G
U N
IT
ED
S
TA
TE
S
M
IL
IT
AR
Y
AC
AD
EM
Y W
ES
T
PO
IN
T, N
Y
A R
C H
D
PA
R
K
AV
EN
U
E
SO
U
TH
N
EW
Y O
R K, N Y
3-
2.
7.
fa x
2.
9.
w w w
.s tv in c.
co m
W
2D S
-1 0-
D -0
A
P R
IL
3/
/2
3:
:0
P
M
S-032
SE
IS
M
IC
T
YP
IC
AL
D
ET
AI
LS
S H
T
D es ig ne r
A ut ho r
C he ck er
0 1/2 1 2
SCALE: 1/2" = 1'-0"1
TYPICAL MASONRY WALLS
ANCHORAGE DETAIL
PLAN
NORTH
0 1/2 1 2
SCALE: 1/2" = 1'-0"2 DETAIL 1 AT CHORD/COLLECTOR
0 1/2 1 2
SCALE: 1/2" = 1'-0"3 TYPICAL PIPE/CONDUIT IN WALL
0 1/2 1 2
SCALE: 1/2" = 1'-0"4
TYPICAL PIPING/CONDUIT THROUGH
CHORD
0 1/2 1 2
SCALE: 1" = 1'-0"5 EXIST SLAB CONNECTION
0 1/2 1 2
SCALE: 1/2" = 1'-0"6
TYPICAL SOLID MASONRY WALL
ANCHORAGE
0 1/2 1 2
SCALE: 1/2" = 1'-0"7 DEFORMED BAR ANCHOR WELDING
0 1/2 1 2
SCALE: 1 1/2" = 1'-0"8
TYPICAL CHORD/COLLECTOR CONSTR.
JOINT
1'-2"
1'-6"UNO
1' 4"
UN
O5"
1/
2"
B12.7 B8.2
NEW SEISMIC
WALL
NEW REINFORCED
CONCRETE CHORD/
COLLECTOR, TYP
28"x12" EXPANDED
POLYSTYRENE FOAM
BLOCKS, TYP
EXISTING
MASONRY
WALL
EXISTING STRUCTURAL
FLOOR SYSTEM, TYP
OPP HAND
DRILL AND GROUT NEW
#4 REINF. INTO (E)
FLOOR JOIST, DO NOT CUT
OR OTHERWISE DAMAGE (E)
REINFORCING, SEE NOTE 2
ON S-030, TYP
2#8 TOP &
BOTT,
TYP UNO
#4@12 CC
STIRRUPS, TYP
#5@12 CC,
TYP
SEE 6/S-033
FOR TYP DIAPH.
REINFORCING,
TYP 2
1/ 2"
5"
4"TYP
1'-6"
1' 4"
B11.2 B11
WHERE SEISMIC CHORD/COLLECTOR IS RUNNING
PERPENDICULAR TO (E) JOISTS, SAW-CUT AND
DEMOLISH (E) 2" CONCRETE SLAB AND CLAY TILES
TO ALLOW INSTALLATION OF NEW SEISMIC
CHORD/COLLECTOR BETWEEN THE (E) JOISTS, DO
NOT DEMOLISH EXISTING JOIST, TYP
CHORD/COLLECTOR LONGITUDINAL
REINFORCING TO BE PLACED ABOVE
AND BELOW EXISTING JOISTS, PLACE
STIRRUPS BETWEEN JOISTS, TYP
EXIST STRUCTURAL
FLOOR SYSTEM,
TYP
NEW REINFORCED
CONCRETE FLOOR
DIAPHRAGM, TYP
28"x12" EXPANDED
POLYSTYRENE FOAM,
TYP
NEW REINFORCED
CONCRETE CHORD/
COLLECTOR, TYP
DRILL AND GROUT NEW
#4 REINF. INTO (E)
FLOOR JOIST, DO NOT CUT
OR OTHERWISE DAMAGE (E)
REINFORCING, SEE NOTE 2
ON S-030, TYP
2#8 TOP &
BOTT,
TYP UNO
#4@12 CC
STIRRUPS, TYP
SEE 6/S-033
FOR TYP DIAPH.
REINFORCING,
TYP
SPLICE LENGTH PER NOTES, TYP
1'-4"
1' 0"
3"
6"
6"
5"
1/
2"
1'-0"
1'-8"
2"
B11.2 B11
± 2'-4"
#5@12" CC ASTM A706
REINFORCING, WELD TO
EXISTING STEEL FRAMING,
TYP
NEW REINFORCED
CONCRETE CHORD/
COLLECTOR, TYP
DRILL AND GROUT NEW
#4 REINF. INTO (E)
FLOOR JOIST, DO NOT CUT
OR OTHERWISE DAMAGE (E)
REINFORCING, SEE NOTE 2
ON S-030, TYP
2#10 TOP &
BOTT,
TYP UNO
#4@12 CC
STIRRUPS, TYP
SEE 6/S-033
FOR TYP DIAPH.
REINFORCING,
TYP
#5 TOP REINFORCING BARS
SERVE AS COLLAPSE PREVENTION TIES
AND MUST BE CONTINUOUS, PROVIDE
LENTON COUPLERS OR APPROVED EQUAL
AS REQUIRED, TYP
LENTON
COUPLERS, TYP
#4@12 CC
STIRRUPS, TYP
2#8 TOP & BOTT,
TYP UNO
#5 TOP & BOTT,
TYP UNO
#5 TO MATCH TOP
SLAB REINF, TYP
#5 TO MATCH TOP
SLAB REINF, TYP
#5@12 CC
CONTINUOUS PROVIDE
LENTON COUPLERS AS
REQU'D, TYP
3"
1/
2"
1'-0"
3'-3"
4"
5" 1/
2"
6"
1'-8"
6"
B10 B9.8
28"x12" EXPANDED
POLYSTYRENE FOAM,
TYP
NEW REINFORCED
CONCRETE FLOOR
DIAPHRAGM, TYP
#4@12" CC ASTM A706
REINFORCING, WELD TO
EXISTING STEEL FRAMING,
TYP
#5 TOP REINFORCING BARS
SERVE AS COLLAPSE PREVENTION TIES
AND MUST BE CONTINUOUS, PROVIDE
LENTON COUPLERS OR APPROVED EQUAL
AS REQUIRED, TYP
#5 TO MATCH TOP
SLAB REINF, TYP
#4@12 CC
STIRRUPS, TYP
LENTON
COUPLERS, TYP
#5@12 CC
CONTINUOUS PROVIDE
LENTON COUPLERS AS
REQU'D, TYP
ADD #5@12 CC,
TYP
ADD #5@12 CC,
TYP
SEE 6/S-033 FOR TYP
DIAPH. REINFORCING, TYP
1/
2"
5"
4"
EXIST STRUCTURAL
FLOOR SYSTEM,
TYP
NEW REINFORCED
CONCRETE FLOOR
DIAPHRAGM, TYP
EXIST STEEL
BEAMS, TYP
5/8"∅x4" @ 16"CC
SHEAR STUDS, ATTACH
TO TOP FLANGE OF (E) BEAMS,
TYP
NEW REINFORCED CONCRETE
JOISTS, SPACING SHALL BE AS
SHOWN ON 6/S-033 AND AS
REQUIRED SUCH THAT AT (E)
STEEL BEAMS JOISTS ARE
INSTALLED CENTERED ON THE
(E) STEEL BEAMS, ADDITIONAL
JOISTS MAY BE REQUIRED, TYP
2' 4"
4"
EQ
UA
L
EQ
UA
L
EQ
UA
L
1'-0"(*)4"
2#
1#5
1#5
2#5
1#5
2#5
2#
2#
1#4 , TYP
TYP FLOOR DIAPHRAGM PLAN DETAIL
NEW REINFORCED
CONCRETE FLOOR
JOISTS, LOCATION
TO MATCH EXISTING,
TYP
(*)TO MATCH
EXIST. JOISTS, TYP
NEW REINFORCED
CONCRETE FLOOR
JOISTS, TYP
28"x12" EXPANDED
POLYSTYRENE FOAM,
TYP
NOTES:
1. PLAN DETAIL APPLIES TO AREAS BETWEEN COLUMN
LINES BA TO BR AT FIRST FLOOR.
2. PLAN DETAIL APPLIES TO AREAS BETWEEN COLUMN
LINES BA TO BR AND B8-B10 AND B11-B13 AT
FLOORS ABOVE FIRST FLOOR.
3. TOP REINFORCING IN BOTH DIRECTIONS SERVE AS
COLLAPSE PREVENTION TIES, PROVIDE LENTON
COUPLERS OR APPROVED EQUAL AS REQUIRED.
GENERAL NOTES:
1. FOR GENERAL NOTES ABBREVIATIONS
AND TYPICAL DETAILS SEE SHEETS
S-030 THROUGH S-040.
2. COORDINATE OPENING SIZES AND
LOCATIONS WITH ARCHITECTURAL
AND MECHANICAL DRAWINGS, TYP.
SHEET
REFERENCE
NUMBER
SHEET OF
D
ES
IG
N
E D
B Y:
D W
N B
Y:
C
H K
BY
S U
BM
IT
TE
D
B Y:
D
AT
E:
S O
LI
C
IT
A
TI
O
N N
O
C O
N
TR
A C
T N
O
FI
LE
N A
M E:
P
LO
TT
E
D B
Y:
S
IZ
E:
P
LO
T D
A
TE
D
AT
E:
D
ES
C
R
IP
TI
O
N
M
AR
K:
A
PP
R
US ARMY CORPS
OF ENGINEERS
NEW YORK DISTRICT
1 2 3 4 5
D
C
B
A
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
N
EW
Y O
R K ht tp w w w
.n an
.u sa ce .a rm y.
m il ar ch ite ct s
- e ng in ee rs pl an ne rs
W
ES
T
N
AT
IO
N
W
ID
E
BL
VD
C O
LU
M
BU
S, O H
IO
4.
4.
fa x
4.
4.
ht tp w w w
.u rs co rp
.c om
SC
IE
N C
E C
EN
TE
R (F
Y1 1-
B
LD
G
U N
IT
ED
S
TA
TE
S
M
IL
IT
AR
Y
AC
AD
EM
Y W
ES
T
PO
IN
T, N
Y
A R
C H
D
PA
R
K
AV
EN
U
E
SO
U
TH
N
EW
Y O
R K, N Y
3-
2.
7.
fa x
2.
9.
w w w
.s tv in c.
co m
W
2D S
-1 0-
D -0
A
P R
IL
3/
/2
3:
:2
P
M
S-033
SE
IS
M
IC
T
YP
IC
AL
D
ET
AI
LS
S H
T
D es ig ne r
A ut ho r
C he ck er
0 1/2 1 2
SCALE: 1" = 1'-0"1 NEW CHORD/DIAPH DETAIL 1
0 1/2 1 2
SCALE: 1" = 1'-0"2 NEW CHORD/DIAPH DETAIL 2
0 1/2 1 2
SCALE: 1" = 1'-0"3 NEW CHORD/DIAPH DETAIL 3
0 1/2 1 2
SCALE: 1" = 1'-0"4 NEW CHORD/DIAPH DETAIL 4
0 1/2 1 2
SCALE: 1" = 1'-0"5 NEW CHORD/DIAPH DETAIL 5
SCALE: 1" = 1'-0"6 NEW CHORD/DIAPH DETAIL 6
1'-0"
1' 0"
9"
FINISHED FLOOR
EXISTING REINFORCED
CONCRETE BEAM,TYP
EXISTING EXTERIOR
MASONRY WALL,
TYP
NEW REINFORCED
CONCRETE SEISMIC
WALL, TYP
NEW REINFORCED
CONCRETE
CORD/COLLECTOR,
TYP
EXISTING EXTERIOR
MASONRY WALL,
TYP
CORE DRILL HOLES
IN (E)BEAM AS REQU'D BY
ADHESIVE ANCHOR SYSTEM
MANUFACTURER, DO NOT CUT
OR DAMAGE (E)REINF., TYP
2#4@12"CC
INSTALL WITH
HILTI RE 500
ADHESIVE, TYP
UNO
DOWELS TO MATCH
(N) WALL REINFORCING,
TYP
NOTE:
FOR ADDITIONAL INFO
NOT SHOWN SEE OTHER
DETAILS ON TYPICAL
DETAILS SHEETS, TYP
FINISHED FLOOR
NEW REINFORCED
CONCRETE SEISMIC
WALL, TYP
EXISTING REINFORCED
CONCRETE BEAM,TYP
PARTIAL DEMOLITION
OF EXIST CONCRETE
TO ALLOW INSTALLATION
OF NEW WALL REINF.
DO NOT CUT/DAMAGE
EXIST REINF., TYP
EXIST. SLAB, TYP
SEE GENERAL
NOTES FOR
SPLICE LENGTH, TYP
CORE DRILL EXISTING BEAM
TO ALLOW INSTALLATION OF
NEW REINF. DO NOT
CUT/DAMAGE EXIST REINF.
GROUT SOLID AFTER REBAR
INSTALLATION,TYP
NOTE:
FOR ADDITIONAL INFO
NOT SHOWN SEE OTHER
DETAILS ON TYPICAL
DETAILS SHEETS, TYP
9" M
IN
1'-0"
FINISHED FLOOR
CORE DRILL EXISTING BEAM
TO ALLOW INSTALLATION OF
NEW REINF. DO NOT
CUT/DAMAGE EXIST REINF.
GROUT SOLID AFTER REBAR
INSTALLATION,TYP
EXIST. SLAB, TYP
NEW REINFORCED
CONCRETE SEISMIC
WALL, TYP 2#4@12" CC
INSTALL WITH
HILTI RE 500
ADHESIVE, TYP UNO
NEW CHORD/
COLLECTOR,
TYP
EXISTING REINFORCED
CONCRETE BEAM,TYP
NOTE:
FOR ADDITIONAL INFO
NOT SHOWN SEE OTHER
DETAILS ON TYPICAL
DETAILS SHEETS, TYP
3"MIN
9" M
IN
2"CLR
FINISHED FLOOR
EXISTING EXTERIOR
MASONRY WALL,
TYP
EXISTING REINFORCED
CONCRETE BEAM, TYP
NEW REINFORCED
CONCRETE SEISMIC
WALL, TYP
PARTIAL DEMOLITION
OF EXIST CONCRETE
TO ALLOW INSTALLATION
OF NEW WALL REINF.
DO NOT CUT/DAMAGE
EXIST REINF., TYP
CORE DRILL EXISTING BEAM
TO ALLOW INSTALLATION OF
NEW WALL VERTICAL REINF.
DO NOT CUT/DAMAGE EXIST
REINF. GROUT SOLID AFTER
REBAR INSTALLATION, TYP
NEW REINFORCED
CONCRETE
CHORD/COLLECTOR,
TYP
FOR SPLICE INFO
SEE GENERAL NOTES,
TYP
NOTE:
FOR ADDITIONAL INFO
NOT SHOWN SEE OTHER
DETAILS ON TYPICAL
DETAILS SHEETS, TYP
#4@12 W/
8" EMBED.
A2
SECOND FLOOR AREA B
175' - 0"
NEW REINFORCED
CONCRETE SEISMIC
WALL, TYP
EXISTING REINFORCED
CONCRETE BEAM,TYP
EXISTING EXTERIOR
MASONRY WALL,
TYP
CORE DRILL EXISTING BEAM
TO ALLOW INSTALLATION OF
NEW REINF. DO NOT
CUT/DAMAGE EXIST REINF.
GROUT SOLID AFTER REBAR
INSTALLATION, TYP
EXIST. SLAB, TYP
DEMOLISH EXIST…