SQUARE
FEET
LINEAR
FEET
1 Sub-Basement Level - Room No.
SB-9 (Life Sciences Lab)
Miscellaneous science lab tables Black science lab counter tops 45 II
2 Sub-Basement Level - Room No.
SB-9F
Miscellaneous science lab tables Black science lab counter tops 95 II
Associated with Old Electrical Panel Black transite electrical panels 90 II
Associated with Old Electrical Panel Gray transite electrical panels 26 II
Throughout room Old braided wire insulation 260 l
4 Sub-Basement Level - Room No.
SB-6 (Mechanical Room)
Vertical line along wall near blue compressor
White/gray pipe insulation 25 l
Look newer; possibly transitePACM Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Non-friable Category I 11, 13, 9B
PACM
Friable
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
PACM
PACM
Non-friable Category I
11, 13, 9B
7PACM
Sub-Basement Level - Room No.
SB-8 (Mechanical Room)
Look newer; possibly transiteNon-friable Category I 11, 13, 9B
11, 13, 9B
PACM; pipe is inaccessible for sampling
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Friable 7, 89 Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Room leads to pipe tunnel; pipe insulation throughout non-suspect
PACM; live electric
PACM; live electric
HBH-26A
Non-friable Category I
NOTES/COMMENTS
ASBESTOS-CONTAINING MATERIALS SUMMARY
ASBESTOS
CONTENT (%)
QUANTITY
ABATEMENT METHOD USACE SETUP
DETAIL SHEETS
OSHA
CLASS
EPA NESHAP
DESIGNATIONMATERIAL DESCRIPTION/TYPEWORK
AREA # AREA NAME MATERIAL LOCATION
LINEAR
FEET
On floor in room 12"x12" white/beige vinyl floor tile and mastic 640 II
Storage closet White/gray pipe insulation 10 l
Basement Level - Shaft Off
Vestibule (outside B-27 office area)
Throughout shaft Pipe and pipe fitting insulation 130 l
Basement Level - Room No. B-21 (Photonics Office areas)
On floor throughout Possible vinyl floor tile and mastic 1,660 II
Basement Level - Room No. B-19 (Conference Room)
On floor throughout Possible vinyl floor tile and mastic 800 II
8 Basement Level - Room No. B-20 (Storage)
Above suspended ceiling Gray pipe and fitting insulation 110 l
9 Basement Level - Room No. B-17 (Nuclear Science lab)
Above suspended ceiling Gray pipe and fitting insulation 50 l
North/south corridor No. 3 (inside Photonics area)
Above suspended ceiling Gray pipe and fitting insulation 100 l
Pipe and pipe fitting insulation 5 l
At entrance Fire door insulation 21 II
Inside chemical exhaust hood Gray transite hood panels 50 II
Miscellaneous science lab tables Black science lab counter tops 60 II
Alongside table countertops Gray tabletop caulking 25 II
Basement Level - Room No. B- 16A1
Miscellaneous science lab tables Black science lab counter tops 120 II
Basement Level - Room No. B- 16A2
Miscellaneous science lab tables Black science lab counter tops 60 II
On floor in room 12"x12" White w/ gray streaks vinyl floor tile and mastic 340 II
Inside chemical exhaust hood Gray transite hood panels 94 II
Miscellaneous science lab tables Black science lab counter tops 54 II
On floor in room 12"x12" White w/ gray streaks vinyl floor tile and mastic 340 II
Behind chemical exhaust hood in back of class Gray pipe fitting insulation debris 1 l
Inside chemical exhaust hood Gray transite hood panels 94 II
Miscellaneous science lab tables Black science lab counter tops 220 II
Basement Level - Room No. B-13
(Transformer Room/Fire Alarm Control Room)
Inside electrical boxes and conduit throughout both rooms Old braided wire insulation 300 l
Pipe and pipe fitting insulation 80 l
Associated with exhaust fan No. 1 Gray vibration dampening cloth 20 l
Inside electrical boxes and conduit Old braided wire insulation 60 l
Lower level, on pipe leading to underneath hallway
White/gray pipe insulation 1 l
Basement Level - Open Pit Area (shaft off west corridor 1)
Throughout shaft White/gray duct insulation 2000 l
Basement Level - Room No. B-06 (Physics Storage)
South side of room White/gray duct insulation 600 l
Associated w/ fan unit Gray/brown vibration dampening cloth 24 l
Inside electrical conduit Old braided wire insulation 100 l
Piping throughout Layered paper pipe insulation 8 l
Piping throughout Gray pipe fitting insulation 7 l
Above suspended ceiling tile throughout room
White/gray pipe insulation 130 l
Above suspended ceiling tile throughout room
Gray pipe fitting insulation 40 l
Miscellaneous science lab tables Black science lab counter tops 410 II
Above suspended ceiling tile throughout room
White/gray pipe insulation 130 l
Above suspended ceiling tile throughout room
Gray pipe fitting insulation 20 l
20 Basement Level - Room No. B- 01B (Accelerator Physics Lab)
Over fiberglass duct insulation Gray spackle material over fiberglass duct insulation
140 l
21 Basement Level - Room No. B- 01C (Metal Shop)
Over fiberglass duct insulation Gray spackle material over fiberglass duct insulation
350 l
Basement Level - Room No. B- 02A (Elevator #1 Motor Room)
Basement Level - Room No. B-01 (Physics Lab)
Basement Level - Room No. B- 01A (Wood Shop)
Basement Level - Room No. B-03 (A/H #9)
Basement Level - Room No. B-27
(Office areas)
Basement Level - Room No. B-14 (Storage)
Basement Level - Room No. B- 16A (Chemistry Lab)
Basement Level - Room No. B- 16A3
Basement Level - Room No. B- 16A4
Basement Level - Room No. B-12 (Mechanical)
Basement Level - Room No. B- 08/10 (Mechanical Room)
BH-122A
(Chrysotile 16%)
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
PACM
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
HBH-20A
HBH-20A
Under canvas cover
Look newer; possibly slate
Friable
Friable 7, 89
Friable 7, 89
Under canvas cover Friable
Friable 7, 89
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Non-friable Category I 11, 13, 9B
Friable 7, 89
7, 89
Friable 7, 89
Friable
Friable 101
Friable 7
7, 89
7, 89
Friable 101
7, 89
Above 1'x1' white/gray hidden spline ceiling system
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Quantity is assumed; shaft is inaccessible
Duct appears to lead into adjacent Open Pit area
PACM; inaccessible for sampling
PACM; possibly live electric
Friable
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Above 1'x1' white/gray hidden spline ceiling system; on fiberglass pipe runs
BH-122A
(Chrysotile 16%)
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
PACM
PACM
BH-33A
(Chrysotile
33.3%)
HBH-32A
BH-32A
(Chrysotile 40%)
HBH-16A
HBH-26A
PACM
PACM; possibly live electric
PACM
PACM; possibly live electric
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Possibly more insulation in crawlspace under hallway
7, 89
Above 1'x1' white/gray hidden spline ceiling system; on fiberglass pipe runs
Above 1'x1' white/gray hidden spline ceiling system
PACM
HBH-10A
BH-26A
(Chrysotile
36.4%) Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Friable
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
PACM; inaccessible for sampling, lots of debris in room
NOTES/COMMENTS
ASBESTOS-CONTAINING MATERIALS SUMMARY
ASBESTOS
CONTENT (%)
QUANTITY
ABATEMENT METHOD USACE SETUP
DETAIL SHEETS
OSHA
CLASS
EPA NESHAP
DESIGNATIONMATERIAL DESCRIPTION/TYPEWORK
AREA # AREA NAME MATERIAL LOCATION
PACM; inaccessible for sampling, lots of debris in room
PACM
PACM
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
7, 89
Friable
Friable
BH-10A
(Chrysotile
57.1%)
BH-07A
(Chrysotile 20%)
HBH-06A
BH-07A
(Chrysotile 20%)
PACM
PACM
Underneath carpeting
HBH-16A
PACM PACM; No access underneath carpeting
PACM; No access underneath carpeting
Non-friable Category I 4, 61
7, 89
PACM
Non-friable Category I 4, 61
Friable 7, 89
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Friable
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
PACM
BH-06A
(Chrysotile 1.6%)
BH-16A
(Chrysotile
10%/Amosite 7%)
PACM
BH-05A
(Chrysotile 3.2%)
PACM
BH-07A
(Chrysotile 20%)
BH-40A
(Chrysotile 3.5%)
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
BH-17A
(Chrysotile
12.1%)
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Non-friable Category I
Non-friable Category I
Look newer; possibly transite
Look newer; possibly transite
Look newer; possibly transite
Non-friable Category I
11, 13, 9B
4, 61
Non-friable Category I
Non-friable Category I
Non-friable Category I
Non-friable Category I
Non-friable Category I
Non-friable Category I
Look newer; possibly transite11, 13, 9B
11, 13, 9B
Above suspended ceiling system7, 89
4, 61
11, 13, 9B
Above suspended ceiling
Above suspended ceiling throughout corridor
Non-friable Category I 11, 13, 9B
11, 13, 9B
11, 13, 9B Look newer; possibly transite
Friable
11, 13, 9B
11, 13, 9B
Non-friable Category I 11, 13, 9B
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
4, 61
Friable 7, 89
PACM
Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Non-friable Category I
HBH-17A Friable
7, 89
PACM
Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Non-friable Category I
Friable
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Friable
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Friable
PACM; No access underneath carpeting
7, 89 PACM; inaccessible for sampling
11, 13, 9B
PACM
Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Friable
LINEAR
FEET
22 1st Floor - Room No. 126 (Vestibule) Miscellaneous science lab table Black science lab counter top (1) 24 II
On floor in room 12"x12" Light blue vinyl floor tile and mastic 700 II
Miscellaneous science lab table Black science lab counter tops 150 II
On floor in room 12"x12" Light blue vinyl floor tile and mastic 490 II
Miscellaneous science lab table Black science lab counter tops 150 II
25 1st Floor - Room No. 122 Miscellaneous science lab table Black science lab counter tops 64 II
26 1st Floor - Room No. 121 Miscellaneous science lab table Black science lab counter tops 64 II
27 1st Floor - Room No. 119 On floor in room 12"x12" Light blue vinyl floor tile and mastic 580 II
28 Pipe shaft (off Room No. 119 closet) Inside access panel in closet Pipe insulation and fittings 270 l
On floor in room 12"x12" Light blue vinyl floor tile and mastic 650 II
Miscellaneous science lab tables Black science lab counter tops 220 II
30 1st Floor - Room No. 116 Miscellaneous science lab tables Black science lab counter tops 60 II
Miscellaneous science lab tables Black science lab counter tops 3360 II
North and south sides of room Transite chemical hood panels (4) 240 II
Miscellaneous science lab tables Black science lab counter tops 120 II
Entrance door Fire door insulation 28 II
1st Floor - Room No. 115A Entrance door Fire door insulation 28 II
32 1st Floor - Room No. 114 Miscellaneous science lab table Black science lab counter top 32 II
Miscellaneous science lab tables Black science lab counter tops 2876 II
South side of room Transite chemical hood panels (2) 120 II
On floor in room 9"x9" white w/ green streaks vinyl floor tile and mastic
620 II
Miscellaneous science lab tables Black science lab counter tops 36 II
On floor in room 9"x9" white w/ green streaks vinyl floor tile and mastic
620 II
Miscellaneous science lab tables Black science lab counter tops 36 II
36 1st Floor - Room No. 107 Miscellaneous science lab tables Black science lab counter tops 36 II
37 1st Floor - Room No. 105 On floor in room Vinyl floor tile and mastic 660 II
38 1st Floor - Room No. 104 Miscellaneous science lab tables Black science lab counter tops 36 II
On floor in room 9"x9" white w/ green streaks vinyl floor tile and mastic
520 II
Miscellaneous science lab tables Black science lab counter tops 150 II
40 1st Floor - Room No. 102 Miscellaneous science lab table Black science lab counter top 36 II
41 1st Floor - Room No. 101A Possible pipe insulation 30 l
1st Floor - Room No. 100A Above 1'x1' ceiling tile Possible pipe insulation above 1'x1' ceiling tile
45 l
Above and below 1'x1' ceiling tile Possible pipe insulation above 1'x1' ceiling tile
125 l
Miscellaneous science lab tables Black science lab counter tops 48 II
Above 1'x1' ceiling tile Possible pipe insulation above 1'x1' ceiling tile
45 l
Miscellaneous science lab tables Black science lab counter tops 48 II
Above 1'x1' ceiling tile Possible pipe insulation above 1'x1' ceiling tile
45 l
Miscellaneous science lab tables Black science lab counter tops 80 II
Above 1'x1' ceiling tile Possible pipe insulation above 1'x1' ceiling tile
45 l
Miscellaneous science lab tables Black science lab counter tops 80 II
1st Floor - Room No. 100G Associated with fan unit Gray vibration dampening cloth 20 l
1st Floor - Room No. 100E
1st Floor - Room No. 103
1st Floor - Room No. 100B
1st Floor - Room No. 100C
1st Floor - Room No. 100D
1st Floor - Room No. 115B
1st Floor - Room No. 111 (Chemistry Lab)
1st Floor - Room No. 110
1st Floor - Room No. 108
1st Floor - Room No. 125
1st Floor - Room No. 124
1st Floor - Room No. 118
1st Floor - Room No. 115 (Chemistry Lab)
7, 89
Non-friable Category I 11, 13, 9B
Non-friable Category I 11, 13, 9B
Friable 7, 89
Friable
7, 89
Friable 7, 89
Non-friable Category I 11, 13, 9B
Friable
7, 89
Friable 7, 89
Non-friable Category I 11, 13, 9B
Friable 7, 89
11, 13, 9B
Non-friable Category I 4, 61
Non-friable Category I 11, 13, 9B
Non-friable Category I 4, 61
Non-friable Category I 11, 13, 9B
Non-friable Category I 4, 61
Non-friable Category I 11, 13, 9B
11, 13, 9B
Non-friable Category I 11, 13, 9B
Non-friable Category I 11, 13, 9B
Non-friable Category I 4, 61
Non-friable Category I 11, 13, 9B
Non-friable Category I 4, 61
Friable 7, 89
Non-friable Category I 11, 13, 9B
Non-friable Category I 11, 13, 9B
Non-friable Category I 4, 61
Non-friable Category I 11, 13, 9B
Non-friable Category I 4, 61
Non-friable Category I 11, 13, 9B
Non-friable Category I 11, 13, 9B
PACM
PACM
HBH-106A
PACM
PACM
PACM
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Look newer; possibly transite
PACM Looks newer; possibly transite
Look newer; possibly transite
Underneath 12"x12" floor tile
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
PACM
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Looks newer; possibly transite
Underneath 12"x12" floor tile
11, 13, 9B
Non-friable Category I 11, 13, 9B
Non-friable Category I 11, 13, 9B
Non-friable Category I
Look newer; possibly transite
Look newer; possibly transite
Look newer; possibly transite
Look newer; possibly transite
Look newer; possibly transite
Look newer; possibly transite
Several vertical pipes in shaft;
appear to go height of building
PACM
PACM
PACM
HBH-105A
PACM
BH-105A
(Amosite 30.8%)
PACM
HBH-106A
PACM
HBH-106A
PACM
PACM
BH-91A
(Chrysotile
20%/Amosite 2%)
PACM
PACM
PACM
PACM
PACM
PACM
PACM
PACM
PACM
Looks newer; possibly transite
Looks newer; possibly transite
NOTES/COMMENTS
ASBESTOS-CONTAINING MATERIALS SUMMARY
ASBESTOS
CONTENT (%)
QUANTITY
ABATEMENT METHOD USACE SETUP
DETAIL SHEETS
OSHA
CLASS
EPA NESHAP
DESIGNATION
MATERIAL DESCRIPTION/TYPEWORK
AREA #
AREA NAME MATERIAL LOCATION
HBH-106A
PACM
Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Look newer; possibly transite
Looks newer; possibly transite
Non-friable Category I 11, 13, 9B
Non-friable Category I
Underneath 12"x12" floor tile
Looks newer; possibly transite
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Non-friable Category I 4, 61
Non-friable Category I 11, 13, 9B
Non-friable Category I
Look newer; possibly transite
Looks newer; possibly transite
PACM; No access above 1'x1' ceiling tile
PACM; No access above 1'x1' ceiling tile
Look newer; possibly transite
PACM; No access to room
PACM; No access above 1'x1' ceiling tile
PACM; No access above 1'x1' ceiling tile
Look newer; possibly slate
Look newer; possibly transite
PACM; No access above 1'x1' ceiling tile
Look newer; possibly transite
PACM
PACM
PACM
HBH-105A
HBH-105A
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
PACM
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Non-friable Category I 11, 13, 9B
Friable
PACM
Non-friable Category I 11,13, 9B
Non-friable Category I 11, 13, 9B
PACM
Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
PACM
Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
LINEAR
FEET
43 2nd Floor - Room No. 221 Miscellaneous science lab tables Black science lab counter tops (6) 220 II
44 2nd Floor - Room No. 220 Miscellaneous science lab tables Black science lab counter tops (7) 950 II
45 2nd Floor - Room No. 218 On floor in room 12"x12" Light blue vinyl floor tile and mastic 640 II
On floor in room Gray vinyl floor tile and mastic 840 II
Miscellaneous science lab tables Black science lab counter tops (6) 480 II
47 2nd Floor - Room No. 214 Miscellaneous science lab tables Black science lab counter tops (5) 164 II
48 2nd Floor - Room No. 213 Miscellaneous science lab table Black science lab counter top (1) 36 II
2nd Floor - Room No. 211 (Amphitheater)
On floor in room 9"x9" white vinyl floor tile and mastic 3600 II
2nd Floor - Mechanical Room (off Room No. 211)
On floor in room 12"x12" beige vinyl floor tile and mastic 260 II
2nd Floor - Storage Room (off Room No. 211)
On floor in room 12"x12" beige vinyl floor tile and mastic 260 II
50 2nd Floor - Room No. 210 On floor in room 9"x9" white w/ green streaks vinyl floor tile and mastic
660 II
51 2nd Floor - Room No. 209 On floor in room 9"x9" white w/ green streaks vinyl floor tile and mastic 600 II
52 2nd Floor - Room No. 208 Miscellaneous science lab tables Black science lab counter tops (5) 164 II
53 2nd Floor - Room No. 207 On floor in room 9"x9" white w/ green streaks vinyl floor tile and mastic
660 II
54 2nd Floor - Room No. 206 On floor in room 9"x9" white w/ green streaks vinyl floor tile and mastic 660 II
On floor in room Beige/white vinyl floor tile and mastic 480 II
Miscellaneous science lab table Black science lab counter top (1) 36 II
On floor in room 12"x12" Light blue vinyl floor tile and mastic 600 II
On floor in room Beige/white vinyl floor tile and mastic 600 II
Miscellaneous science lab tables Black science lab counter tops (5) 132 II
On floor in room 9"x9" white w/ green streaks vinyl floor tile and mastic
560 II
Miscellaneous science lab table Black science lab counter top (1) 36 II
On floor in room 9"x9" beige vinyl floor tile and mastic 4,600 II
Restroom Pipe insulation and fittings 12 l
Hallway near kitchen (above ceiling) Pipe fitting insulation 1 l
2nd Floor - Room No. 217
2nd Floor - Room No. 202
4, 61
Friable 7, 89
Non-friable Category I 4, 61
Friable 7, 89
Non-friable Category I 11, 13, 9B
4, 61
Non-friable Category I 11, 13, 9B
11, 13, 9B
Non-friable Category I 11, 13, 9B
Non-friable Category I 4, 61
Non-friable Category I 4, 61
11, 13, 9B
2nd Floor - Room No. 203
2nd Floor - Room No. 205
11, 13, 9B
Non-friable Category I 4, 61
Non-friable Category I 4, 61
Non-friable Category I
4, 61
Bottom layer under gray and white linoleum
Look newer; possibly transite
Look newer; possibly transite
Floor tile is non-ACM
Look newer; possibly transite
Looks newer; possibly transite
Top layer above beige vinyl floor tile
Bottom layer underneath 12"x12" light blue vinyl tile
Look newer; possibly transite
Looks newer; possibly transite
Look newer; possibly transite
Look newer; possibly transite
PACM
NOTES/COMMENTS
PACM
Non-friable Category I 11, 13, 9B Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Non-friable Category I
ASBESTOS
CONTENT (%)
QUANTITY
ABATEMENT METHOD USACE SETUP
DETAIL SHEETS
OSHA
CLASS
EPA NESHAP
DESIGNATION
PACM
HBH-92A
H-BH-92A
MATERIAL DESCRIPTION/TYPEWORK
AREA #
AREA NAME MATERIAL LOCATION
ASBESTOS-CONTAINING MATERIALS SUMMARY
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
PACM
PACM
H-BH-106AM
BH-119A
(Chrysotile 3.8%)
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
H-BH-40A
PACM
BH-106A
(Chrysotile 1.9%)
H-BH-92A
H-BH-40A
H-BH-92A
PACM
H-BH-92A
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Non-friable Category I 4, 61
Non-friable Category I 4, 61
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Non-friable Category I
PACM
PACM
BH-107A
(Chrysotile 4.7%)
H-BH-92A
BH-109A
(Chrysotile 1.7%)
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
4, 61
Non-friable Category I 11, 13, 9B
Non-friable Category I 4, 61
Non-friable Category I 11, 13, 9B
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Non-friable Category I
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Non-friable Category I
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Non-friable Category I
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Bottom layer underneath 12"x12" light blue vinyl floor tile
Non-friable Category I Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Non-friable Category I 4, 61
Non-friable Category I
4, 61
Looks newer; possibly transite
Quantity is estimated. Underneath carpeting was inaccessible
2nd Floor - Room No. 200 Offices
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
PACM
PACM
PACM
LINEAR
FEET
59 3rd Floor - Room No. 327 Miscellaneous table Black science lab counter top (1) 40 II
Miscellaneous tables Black science lab counter tops (5) 220 II
Associated with chemical hood Lab hood transite panels 60 II
61 3rd Floor - Room No. 325 Miscellaneous table Black science lab counter top (1) 40 II
62 3rd Floor - Room No. 324 Miscellaneous table Black science lab counter top (1) 40 II
63 3rd Floor - Room No. 323 Miscellaneous table Black science lab counter top (1) 30 II
64 3rd Floor - Room No. 322 Miscellaneous table Black science lab counter top (1) 40 II
65 3rd Floor - Room No. 321 Miscellaneous table Black science lab counter top (1) 40 II
66 3rd Floor - Room No. 320 Miscellaneous table Black science lab counter top (1) 40 II
67 3rd Floor - Room No. 319 Miscellaneous table Black science lab counter top (1) 40 II
68 3rd Floor - Room No. 318 Miscellaneous table Black science lab counter top (1) 40 II
69 3rd Floor - Room No. 317 Miscellaneous table Black science lab counter top (1) 40 II
70 3rd Floor - Room No. 316 Miscellaneous table Black science lab counter top (1) 40 II
71 3rd Floor - Room No. 315 Miscellaneous tables Black science lab counter tops (5) 180 II
72 3rd Floor - Room No. 314 Miscellaneous tables Black science lab counter top (1) 40 II
On floor in room 12"x12" Light blue vinyl floor tile and mastic 640 II
Instructor's table Black science lab counter top (1) 40 II
74 3rd Floor - Room No. 309 Instructor's table Black science lab counter top (1) 40 II
On floor in room 9"x9" gray vinyl floor tile and mastic 760 II
Miscellaneous science lab tables Black science lab counter tops (5) 200 II
Miscellaneous science lab tables Black science lab counter tops (5) 200 II
On floor in room Possible vinyl floor tile 700 II
77 3rd Floor - Room No. 306 Instructor's table Black science lab counter top (1) 40 II
78 3rd Floor - Room No. 304 Instructor's table Black science lab counter top (1) 40 II
79 3rd Floor - Suite 300 (Offices A through I)
Throughout floor (under carpet) Possible vinyl floor tile under carpet 4,600 II
75 3rd Floor - Room No. 308
76 3rd Floor - Room No. 307
60 3rd Floor - Room No. 326
73 3rd Floor - Room No. 310
Non-friable Category I 11, 13, 9B
Non-friable Category I 11, 13, 9B
11, 13, 9B
11, 13, 9B
Non-friable Category I 4, 61
Non-friable Category I 11, 13, 9B
Non-friable Category I
Non-friable Category I
Non-friable Category I 11, 13, 9B
Non-friable Category I 4, 61
Non-friable Category I 11, 13, 9B
Non-friable Category I
11, 13, 9B
11, 13, 9B
Non-friable Category I 11, 13, 9B
Non-friable Category I 11, 13, 9B
11, 13, 9B
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
PACM
PACM
PACM
PACM
PACM
PACM
H-BH-106AM
Quantity is estimated. Underneath carpet was not accessed during survey.
Looks newer; possibly transite
Non-friable Category I 11, 13, 9B
Non-friable Category I 4, 61
Non-friable Category I 11, 13, 9B
PACM; Room was not accessed during survey.
Looks newer; possibly transite
PACM
PACM
Look newer; possibly transite
Look newer; possibly transite
Non-friable Category I 11, 13, 9B
Non-friable Category I 11, 13, 9B
PACM
PACM
PACM
PACM
PACM
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
PACM
NOTES/COMMENTS
ASBESTOS-CONTAINING MATERIALS SUMMARY
ASBESTOS
CONTENT (%)
QUANTITY
ABATEMENT METHOD USACE SETUP
DETAIL SHEETS
OSHA
CLASS
EPA NESHAP
DESIGNATION
MATERIAL DESCRIPTION/TYPEWORK
AREA #
AREA NAME MATERIAL LOCATION
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
PACM
Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
PACM
PACM
PACM
PACM
PACM
PACM Look newer; possibly transite
Look newer; possibly transite
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Non-friable Category I 11, 13, 9B
Non-friable Category I
Non-friable Category I
Look newer; possibly transite
Look newer; possibly transite
Look newer; possibly transite
Look newer; possibly transite
Look newer; possibly transite
Non-friable Category I 11, 13, 9B
Non-friable Category I 11, 13, 9B
Floor tile is non-ACM
Look newer; possibly transite
Look newer; possibly transite
Look newer; possibly transite
Look newer; possibly transite
Looks newer; possibly transite.
Closet was locked, no access
Look newer; possibly transite
PACM
PACM
PACM Non-friable Category I 11, 13, 9B
Non-friable Category I 11, 13, 9B
Non-friable Category I 4, 61
Look newer; possibly transite
Look newer; possibly slate
PACM; Room was not accessed during survey.
LINEAR
FEET
80 4th Floor - Room No. 427 Instructor's table and adjacent table
Black science lab counter tops (2) 18 II
Miscellaneous tables Black science lab counter tops (5) 120 II
Inside chemical exhaust hood Transite chemical hood panels 55 II
82 4th Floor - Room No. 425 Instructor's table and fume hood Black science lab counter tops (2) 24 II
83 4th Floor - Room No. 424 Instructor's table and fume hood Black science lab counter tops (2) 24 II
84 4th Floor - Room No. 423 Instructor's table and fume hood Black science lab counter tops (2) 24 II
85 4th Floor - Room No. 422 Instructor's table and fume hood Black science lab counter tops (2) 24 II
86 4th Floor - Room No. 421 Instructor's table Black science lab counter top (1) 21 II
87 4th Floor - Room No. 420 Instructor's table Black science lab counter top (1) 18 II
88 4th Floor - Room No. 419 Instructor's table Black science lab counter top (1) 18 II
89 4th Floor - Room No. 418 Instructor's table Black science lab counter top (1) 18 II
90 4th Floor - Room No. 416 Instructor's table Black science lab counter top (1) 18 II
91 4th Floor - Room No. 415 Miscellaneous tables Black science lab counter tops (5) 132 II
4th Floor - Room No. 412
(Kendrick Hall) On floor of room 9"x9" White w/ streaks vinyl floor tile and mastic
2,300 II
93 4th Floor - Room No. 412E Associated with AC-12 fan unit ductwork Vibration dampening cloth 32 l
94 4th Floor - Room No. 410 On floor in room 12"x12" Light blue vinyl floor tile and mastic 660 II
95 4th Floor - Room No. 408 On floor in room 12"x12" Light blue vinyl floor tile and mastic 460 II
96 4th Floor - Room No. 407 On floor in room 12"x12" Light blue vinyl floor tile and mastic 460 II
97 4th Floor - Room No. 405 On floor in room 12"x12" Light blue vinyl floor tile and mastic 640 II
98 4th Floor - North Office Areas (400A through 400J) Underneath carpeting throughout Possible vinyl floor tile under carpet 4,420 II
98A 4th Floor - Above plaster ceiling throughout the 4th floor Above plaster ceiling throughout the 4th floor Pipe and pipe fitting insulation 1,500 l
4th Floor - Room No. 426
PACM
PACM
PACM
PACM
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
H-BH-106AM
H-BH-106AM
H-BH-106AM
H-BH-106AM
PACM
Floor tile is non-ACM
Floor tile is non-ACM
PACM
Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
PACM
PACM
PACM
PACM
Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
PACM
Non-friable Category I 4, 61
Non-friable Category I
Non-friable Category I
11, 13, 9B
Non-friable Category I
Non-friable Category I
Floor tile is non-ACM
Look newer; possibly transitePACM
Look newer; possibly transite
11, 13, 9B
PACM
Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
PACM
Look newer; possibly transite
Look newer; possibly transite
Look newer; possibly transite
Look newer; possibly transite
Look newer; possibly transite
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
11, 13, 9B
Non-friable Category I
11, 13, 9B
Look newer; possibly transite
Non-friable Category I
Non-friable Category I
11, 13, 9B
11, 13, 9B
11, 13, 9B
Look newer; possibly transite
PACM based on previous sample results.
Quantity is estimated
Look newer; possibly transite
11, 13, 9B
4, 61
11, 13, 9B
MATERIAL DESCRIPTION/TYPEWORK
AREA # AREA NAME MATERIAL LOCATION NOTES/COMMENTS
ASBESTOS-CONTAINING MATERIALS SUMMARY
ASBESTOS
CONTENT (%)
QUANTITY
ABATEMENT METHOD USACE SETUP
DETAIL SHEETS
OSHA
CLASS
EPA NESHAP
DESIGNATION
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Floor tile is non-ACM4, 61Non-friable Category I
11, 13, 9B
Look newer; possibly transite
Look newer; possibly transite
4, 61
Non-friable Category I 4, 61
Non-friable Category I
Non-friable Category I
Non-friable Category I
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
PACM
PACM
PACM
Friable 7, 89
Non-friable Category I
Non-friable Category I
Non-friable Category I
11, 13, 9B
Non-friable Category I
Non-friable Category I
11, 13, 9B
11, 13, 9B
4, 61 Underneath carpet was not accessed during survey.
PACM
Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
Friable 7, 89
PACM; Contractor will need to demolish plaster ceiling in select multiple areas under piping as needed throughout floor to access the ACM pipe insulation for removal
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Non-friable Category I
LINEAR
FEET
99 5th Floor - Room No. 526 Instructor's table and fume hood Black science lab counter tops (2) 48 II
Above 1'x1' hidden spline ceiling tile/plaster ceiling and behind radiator walls Pipe and pipe fitting insulation 150 l
100 5th Floor - Elevator Motor Room Inside electrical panel Electrical backing boards 2 II
101 5th Floor - Pipe shaft adjacent to Elevator Motor Room
Behind wall in pipe shaft adjacent to motor room
Solid white/gray pipe insulation 15 per floor l
Quantity is assumed for each floor; shaft was not accessible on all floors. Contractor shall demolish existing plaster walls under tent containment to access pipe insulation for removal.
PACM
PACM
H-BH-91A
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
11,13,9B
OSHA
CLASS
EPA NESHAP
DESIGNATIONMATERIAL DESCRIPTION/TYPEWORK
AREA # AREA NAME MATERIAL LOCATION
Non-friable Category I
Friable
11,13,9B
7, 89
NOTES/COMMENTS
ASBESTOS-CONTAINING MATERIALS SUMMARY
ASBESTOS
CONTENT (%)
QUANTITY
ABATEMENT METHOD USACE SETUP
DETAIL SHEETS
Quantity is assumed above plaster ceiling and behind walls as this area was inaccessible;
contractor shall demolish plaster ceiling and wall at radiator unit under tent containment to access the pipe insulation for removal
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Friable 7, 89
Non-friable Category I Look newer; possibly transite
SQUARE
FEET
LINEAR
FEET
102 6th Floor Tower Stairwell Behind wall in pipe shaft adjacent to steam heating unit Solid white/gray pipe insulation 15 per floor l
Instructor's table and fume hood Black science lab counter tops (2) 48 II
Behind plaster radiator wall Pipe and pipe fitting insulation 20 l
On floor of closet in room 12"x12" gray/tan vinyl floor tile and mastic 20 II 4,61
MATERIAL LOCATION NOTES/COMMENTS
Non-friable Category I
7, 89 Assumed ACM piping exists behind wall on either side of radiator unit; contractor shall demolish as necessary to access for removal 103 6th Floor - Room No. 626
BH-63A
(Chrysotile 3%)
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard
Non-friable Category I
Friable
ASBESTOS-CONTAINING MATERIALS SUMMARY
ASBESTOS
CONTENT (%)
QUANTITY
ABATEMENT METHOD USACE SETUP
DETAIL SHEETS
OSHA
CLASS
EPA NESHAP
DESIGNATIONMATERIAL DESCRIPTION/TYPEWORK
AREA # AREA NAME
BH-73A
(Chrysotile
15%/Amosite 3%)
Contractor shall demolish plaster wall in this stairwell as necessary to gain access to pipe risers on each floor for removal.
PACM Look newer; possibly transite
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard 7, 89Friable
4,61,9B
LINEAR
FEET
On floor underneath carpeting throughout room
9"x9" Brown w/ streaks vinyl floor tile and mastic
4,000 II
Between interior and exterior perimeter block walls Black tar waterproofing material 1,800 II
4, 61
Non-friable Category I 4, 61
1st Floor - Moore Wing, Open Library, Room No. 128 HLib-04A
(5.1% chrysotile)
E01 (8/08)
Non-friable Category I
NOTES/COMMENTS
Localized removal as necessary on perimeter walls between interior and exterior block walls
Occupational, Safety and Health Administration's (OSHA) Asbestos
Construction Standard Occupational, Safety and Health
Administration's (OSHA) Asbestos Construction Standard
USACE SETUP
DETAIL SHEETS
OSHA
CLASS
EPA NESHAP
DESIGNATIONMATERIAL DESCRIPTION/TYPE
WORK
AREA # AREA NAME MATERIAL LOCATION
ASBESTOS-CONTAINING MATERIALS SUMMARY
ASBESTOS
CONTENT (%)
QUANTITY
ABATEMENT METHOD
DN
DN
DN
DN
UP
PLUMBING
B-S08
STEAM TUNNEL
ENTRY
B-S07
CLASSROOM
B-S03
OFFICE
B-S05
STOR
B-S04
MECHANICAL
B-S01
TOILET
B-S09
JAN
B-S10
ELEV #3
VESTIBULE
B-S02
CORRIDOR
B-SC1
CORRIDOR
B-SC2
WRITE UP
C-S02
FUTURE NMR
C-S03
DATA COMM
C-S05
CHEM
ENGINEERING
C-S01
CONTAINED
VENTILATED
BAY
C-S04
CORRIDOR
C-SC4 C
O
R R
ID
O
R
C -S
C
C O
R R
ID
O
R
C -S
C
PLUMBING
C-S06
AREA C
AREA D
AREA B
(SEE A-111B)
AREA E
A R
E A
C (S
E E
A -1
C
AREA E
AREA A
AREA B
(SEE A-111B)
AREA A
A R
E A
B (S
E E
A -1
B
A R
E A
E
A R
E A
B (S
E E
A -1
B
AREA B
(SEE A-111B)
AREA C
(SEE A-111C)
A R
E A
A
A R
E A
D
A R
E A
A
A R
E A
E
OVERALL FLOOR PLAN
GENERAL NOTES
1. LIFE SAFETY SHEETS G-101 THROUGH G-108 INDICATE CONTROL AREA LIMITS, EXIT
TRAVEL DISTANCES, FIRE EXTINGUISHER LOCATIONS, AND LOCATIONS & RATINGS OF
BUILDING WALLS.
2. ALL PENETRATIONS OF FIRE RATED ASSEMBLIES TO BE PROPERLY
PROTECTED/SEALED AS INDICATED ON DETAILS ON A-502 & A-503.
3. NOTE THAT ALL HVAC SHAFTS TO BE 2 HOUR FIRE-RATED WALL CONSTRUCTION WHEN
CONNECTING MORE THAN TWO FLOORS.
4. NOTE THAT ALL ELEVATED FLOOR SLABS TO BE 2 HOUR FIRE-RATED CONSTRUCTION
EXCEPT WHERE NOTED.
5. SEE 1/8" SCALE PLANS FOR CLARIFICATION OF COLUMN LINE LOCATIONS &
DESIGNATIONS WHERE MULTIPLE COLUMN LINES OVERLAP.
6. PHASING REFERENCES ON DWGS. PERTAIN TO THE CONSTRUCTION PHASING OF THE
PROJECT. NOTE: THIS PROJECT TO BE CONSTRUCTED IN PHASES TO MAINTAIN
EXISTING SCIENCE CENTER OPERATIONS. REFER TO PHASING DRAWINGS FOR EACH
MAJOR DISCIPLINE AS WELL AS RELATED PHASING INFORMATION INCLUDED IN THE
SPECIFICATIONS.
7. REFER TO SHEET G-014 FOR A LIST OF PROJECT OPTIONS INDICATING SPECIFIC ITEMS
TO BE INCLUDED WITH SUBMITTED BIDS THAT ARE IN ADDITION TO THE BASE BID
WORK.
8. AREA A, ALSO KNOWN AS BUILDING 753N, IS A PREVIOUS PHASE OF WORK IN PROJECT
USMA_SCICTR_PN55627.
A
B
D
C
E
SHEET
REFERENCE
NUMBER
SHEET OF
D E
S
IG
N E
D B
Y
D W
N B
Y
C H
K B
Y
S U
B M
IT
T
E D
B Y
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
F
IL
E N
A M
E
P L O
T T
E D
B Y
S
IZ
E
P
L O
T D
A T
E
D A
T E
D
E S
C R
IP
T
IO
N
M
A R
K
A P
P R
US ARMY CORPS
OF ENGINEERS
NEW YORK DISTRICT
1 2 3 4 5
D
C
B
A
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
N E
W Y
O R
K h tt p \w w w
.n a n .u s a c e .a rm y.
m il a rc h it e c ts e n g in e e rs p la n n e rs
W
E S
T N
A T
IO
N
W
ID
E B
L V
D
C O
L U
M B
U S
O
H
IO
.4
.4 f a x
.4
.0 h tt p /w w w
.u rs c o rp
.c o m
S C
IE
N
C E
C E
N T
E R
(F Y
-B
L D
G
U N
IT
E
D S
T A
T E
S M
IL
IT
A R
Y A
C A
D E
M Y
W E
S T
P O
IN
T
N
Y
A R
C H
D
P
A R
K A
V E
N U
E S
O U
T H
N E
W Y
O R
K
N Y
-1
.7
.4 f a x
.5
.5 w w w .s tv in c .c o m
W D
S -1
-D
-0
/4
/2
:1
:1
A
M
A-101
S U
B -B
A S
E M
E N
T F
L O
O R
O V
E R
A L
L P
L A
N
N K
P
P G
M D
L P
A
P R
IL
U S
M A
S
C
IC
T R
P
N A
-1 X
X X
0 8 16 324
SCALE: 1/16" = 1'-0"
SUB-BASEMENT FLOOR
OVERALL PLAN
PLAN
NORTH
DN
DN
UP
UP
DN
DN
UP
UP
UP
UP DN
DN
OVERALL FLOOR PLAN
GENERAL NOTES
1. LIFE SAFETY SHEETS G-101 THROUGH G-108 INDICATE CONTROL AREA LIMITS, EXIT
TRAVEL DISTANCES, FIRE EXTINGUISHER LOCATIONS, AND LOCATIONS & RATINGS OF
BUILDING WALLS.
2. ALL PENETRATIONS OF FIRE RATED ASSEMBLIES TO BE PROPERLY
PROTECTED/SEALED AS INDICATED ON DETAILS ON A-502 & A-503.
3. NOTE THAT ALL HVAC SHAFTS TO BE 2 HOUR FIRE-RATED WALL CONSTRUCTION WHEN
CONNECTING MORE THAN TWO FLOORS.
4. NOTE THAT ALL ELEVATED FLOOR SLABS TO BE 2 HOUR FIRE-RATED CONSTRUCTION
EXCEPT WHERE NOTED.
5. SEE 1/8" SCALE PLANS FOR CLARIFICATION OF COLUMN LINE LOCATIONS &
DESIGNATIONS WHERE MULTIPLE COLUMN LINES OVERLAP.
6. PHASING REFERENCES ON DWGS. PERTAIN TO THE CONSTRUCTION PHASING OF THE
PROJECT. NOTE: THIS PROJECT TO BE CONSTRUCTED IN PHASES TO MAINTAIN
EXISTING SCIENCE CENTER OPERATIONS. REFER TO PHASING DRAWINGS FOR EACH
MAJOR DISCIPLINE AS WELL AS RELATED PHASING INFORMATION INCLUDED IN THE
SPECIFICATIONS.
7. REFER TO SHEET G-014 FOR A LIST OF PROJECT OPTIONS INDICATING SPECIFIC ITEMS
TO BE INCLUDED WITH SUBMITTED BIDS THAT ARE IN ADDITION TO THE BASE BID
WORK.
8. AREA A, ALSO KNOWN AS BUILDING 753N, IS A PREVIOUS PHASE OF WORK IN PROJECT
USMA_SCICTR_PN55627.
S A
F E
T Y
S P
L Y
T E
C H
B -B
GAS HOLDING
B-B02
SUPPLY TECH
B-B03
JAN BREAK
B-B04
ELEC
B-B01
CLASSROOM
B-B06
JA
N
B -B
BLDG MAINT/
STOR
B-B09
CLASSROOM
B-B11
CLASSROOM
B-B10
CLASSROOM
B-B12
CLASSROOM
B-B13
CLASSROOM
B-B16
CLASSROOM
B-B17
WOMEN
SHOWER
B-B18
TOILET
B-B15
C O
R R
ID
O
R
B -B
C
C O
R R
ID
O
R B
-B C
CORRIDOR
B-BC5
CORRIDOR
B-BC6
CORRIDOR
B-BC7
CORRIDOR
B-BC8
V E S
T
IB
U L E
B -B
C
STORB-B14
ELEV #3
STAIR B2
B-BS2
CADET
PROJECT LAB
E-B01
LAB STOR
E-B02
CORRIDOR
E-BC4
CORRIDOR
E-BC2
CORRIDOR
E-BC1
LASER
RES/CHEM
E-B03
LASER
RESEARCH
E-B04
EXTERIOR
COURTYARD
E-B08
LASER EQUIP
STOR/REPAIR
E-B06
LASER
RESEARCH
E-B05
HIGH ENERGY
LASER
RESEARCH
E-B07
C O
R R
ID
O
R
E -B
C
MATL SCI
ACCEL LAB
D-B01
MACHINE SHOP
D-B02
WELDING RM
D-B05
ELECTRONICS
D-B06
WOOD SHOP
D-B03
ELEC
C-B04
JAN
C-B06
BLDG STOR
SPT
C-B05
MAIN ELEC
SERV
C-B10
PHYSICS
CLASSRM
C-B08
PHYSICS
WORKRM
C-B09
MEN
C-B07
CORRIDOR
C-BC1
RAD DETECT
LAB/CLSRM
C-B12
STORAGE
C-B11
SUB-CRIT NUC
FACIL
C-B15
RSO LAB
C-B16ANTE
C-B14
JAN
D-B08
NUCL ENGR
LAB
C-B17
CORRIDOR
D-BC2
STAIR D1
D-BS1
CORRIDOR
C-BC2
STAIR C1
C-BS1
CORRIDOR
C-BC5
WOMEN
C-B18
PHYSICS
CLASSRM
C-B01
PHYSICS
WORKRM
D-B12
FXD
EXPERIMTL
PHYSICS
D-B09
GEN STOR
D-B07
MODERN
PHYSICS
WORKRM
D-B10
PREP/ STOR
D-B11
MODERN
PHYSICS
WORKRM
C-B02
COMM
C-B03
CLEAN RM/
PREP STOR
D-B04
WOMEN
SHOWER
ENTRY
C-B19
C O
R R
ID
O
R
C -B
C
VESTIBULE
C-B20
DUST
COLLECTOR
MER
D-B13
CORRIDOR
D-BC1
CORRIDOR
D-BC3
ELEV #4
BLDG STOR
C-B13
AREA C
AREA D
A R
E A
C
AREA E
(SEE A-112E)
AREA A
AREA B
AREA A
A R
E A
B
A R
E A
E
A R
E A
B
AREA E
AREA C
A R
E A
A
A R
E A
D (S
E E
A -1
D
A R
E A
A
A R
E A
E (S
E E
A -1
E
A
R E
A E
A R
E A
B
A
B
D
C
E
SHEET
REFERENCE
NUMBER
SHEET OF
D E
S
IG
N E
D B
Y
D W
N B
Y
C H
K B
Y
S U
B M
IT
T
E D
B Y
D A
T E
S O
L
IC
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
F
IL
E N
A M
E
P L O
T T
E D
B Y
S
IZ
E
P
L O
T D
A T
E
D A
T E
D
E S
C R
IP
T
IO
N
M
A R
K
A P
P R
US ARMY CORPS
OF ENGINEERS
NEW YORK DISTRICT
1 2 3 4 5
D
C
B
A
U .S
A
R M
Y E
N G
IN
E
E R
D
IS
T R
IC
T
N E
W Y
O R
K h tt p \w w w
.n a n .u s a c e .a rm y.
m il a rc h it e c ts e n g in e e rs p la n n e rs
W
E S
T N
A T
IO
N
W
ID
E B
L V
D
C O
L U
M B
U S
O
H
IO
.4
.4 f a x
.4
.0 h tt p /w w w
.u rs c o rp
.c o m
S C
IE
N
C E
C E
N T
E R
(F Y
-B
L D
G
U N
IT
E
D S
T A
T E
S M
IL
IT
A R
Y A
C A
D E
M Y
W E
S T
P O
IN
T
N
Y
A R
C H
D
P
A R
K A
V E
N U
E S
O U
T H
N E
W Y
O R
K
N Y
-1
.7
.4 f a x
.5
.5 w w w .s tv in c .c o m
W D
S -1
-D
-0
/4
/2
:4
:5
A
M
A-102
B A
S E
M E
N T
F L
O O
R O
V E
R A
L L P
L A
N
N K
P
P G
M D
L P
A
P R
IL
U S
M A
S
C
IC
T R
P
N A
-1 X
X X
0 8 16 324
SCALE: 1/16" = 1'-0"
BASEMENT FLOOR
OVERALL PLAN
DN
DN
DN
UP
UPDN
DN
DN
UP
UP
DN
DN
DN
UP
DN
DN
UP
UP
UP
OVERALL FLOOR PLAN
GENERAL NOTES
1. LIFE SAFETY SHEETS G-101 THROUGH G-108 INDICATE CONTROL AREA LIMITS, EXIT
TRAVEL DISTANCES, FIRE EXTINGUISHER LOCATIONS, AND LOCATIONS & RATINGS OF
BUILDING WALLS.
2. ALL PENETRATIONS OF FIRE RATED ASSEMBLIES TO BE PROPERLY
PROTECTED/SEALED AS INDICATED ON DETAILS ON A-502 & A-503.
3. NOTE THAT ALL HVAC SHAFTS TO BE 2 HOUR FIRE-RATED WALL CONSTRUCTION WHEN
CONNECTING MORE THAN TWO FLOORS.
4. NOTE THAT ALL ELEVATED FLOOR SLABS TO BE 2 HOUR FIRE-RATED CONSTRUCTION
EXCEPT WHERE NOTED.
5. SEE 1/8" SCALE PLANS FOR CLARIFICATION OF COLUMN LINE LOCATIONS &
DESIGNATIONS WHERE MULTIPLE COLUMN LINES OVERLAP.
6. PHASING REFERENCES ON DWGS. PERTAIN TO THE CONSTRUCTION PHASING OF THE
PROJECT. NOTE: THIS PROJECT TO BE CONSTRUCTED IN PHASES TO MAINTAIN
EXISTING SCIENCE CENTER OPERATIONS. REFER TO PHASING DRAWINGS FOR EACH
MAJOR DISCIPLINE AS WELL AS RELATED PHASING INFORMATION INCLUDED IN THE
SPECIFICATIONS.
7. REFER TO SHEET G-014 FOR A LIST OF PROJECT OPTIONS INDICATING SPECIFIC ITEMS
TO BE INCLUDED WITH SUBMITTED BIDS THAT ARE IN ADDITION TO THE BASE BID
WORK.
8. AREA A, ALSO KNOWN AS BUILDING 753N, IS A PREVIOUS PHASE OF WORK IN PROJECT
USMA_SCICTR_PN55627.
A
B
D
C
E
ELEC
B-101
PREP STOR
B-105
GEN & ADVNCD
CHEM
B-106
CLASSROOM
B-109
CADET READ
RM
B-102
COMM
B-114
MEN
B-112
CLASSROOM
B-111
STAIR B2
B-1S2
TOILET
B-110
S T
A
IR
B
B -1
S
PREP STOR
B-103
GEN & ADVNCD
CHEM
B-104
GEN & ADVNCD
CHEM
B-107
GEN & ADVNCD
CHEM
B-108
ELEV #3
C O
R R
ID
O
R
B -1
C
CORRIDOR
B-1C2
ROOF TOP
COURT
B-115
CORRIDOR
B-1C3
CORRIDOR
B-1C4
CONF RM/TECH
JOURN
E-119
SR FACULTY
E-110
FILES
E-102
CLOSET
E-120
FACULTY
E-101
ADMIN OFFICE
E-104
OFFICE
E-103
CORRIDOR
E-1C1
OFC/WRK/MAIL/RES
E-109
SUPP T
E-107
WOMEN
E-106
MEN
E-105
SR FACULTY
E-111
SR FACULTY
E-112
C…