TMP_Existing Design_Procedure.pdf

PDF 72 KB Posted

Attached to
Fort Randall Major Unit Rehabilitation Project
Solicitation number
W9128F21R0005
Issued by

About this file

This document contains a federal contract solicitation and related technical file. The solicitation is for the Fort Randall Major Unit Rehabilitation Project to be awarded by the Department of the Army Corps of Engineers Engineering District Omaha. Interested parties must submit responses by March 25, 2021 at 2pm Central. The solicitation is unrestricted and open to both large and small businesses. A site visit will be held on either January 12 or 13, 2021 from 9am, with attendance limited due to COVID-19 restrictions. The technical file provides instructions for installing a cavitation scaffolding system on a hydroelectric unit, including safety procedures and equipment placement.

View the file

Other files

File Type Posted
Am0006 W9128F21R0005.pdf PDF
Am0005 W9128F-21-R-0005.pdf PDF
9104134 StandoffInsulator.pdf PDF
Am0004 W9128F-21-R-0005.pdf PDF
9040123 Penstock 16 inch.JPG JPG image
9040124 Air Depression Diaphragm Valve 1.jpg JPG image
9045637 Drawings_Headcover Access Inquiry.pdf PDF
9040124 Air Depression Diaphragm Valve 2 .jpg JPG image
9040123 Penstock 12 inch valve.JPG JPG image
Am0003 W9128F21R0005 FR MUR.pdf PDF
20210223_093629.jpg JPG image
20210223_091749.jpg JPG image
coc lab_250047.pdf PDF
0250047-PLM.pdf PDF
20210223_093204.jpg JPG image
20210223_092341.jpg JPG image
TMP_Existing Design_Component Overview.pdf PDF
Pages from Generator Test Report - Westinghouse.pdf PDF
TMP_Existing Design_Drawings.pdf PDF
Waterway Drawings.pdf PDF
Am0002 - W9128F21R0005.pdf PDF
195215A Pressure Tank.pdf PDF
195214A Pressure Tank.pdf PDF
18-C-5325_Stator Coil Windings.pdf PDF
AM0001_W9128F21R0005 - FR MUR.pdf PDF
Water Quality - Fort Randall.pdf PDF
12_13 Jan 21 Fort Randall Site Visit Presentation.pdf PDF
Site Visit Sign-In_13 Jan 21_FR Major Rehab.pdf PDF
Site Visit Sign-In_12 Jan 21_FR Major Rehab.pdf PDF
Part 1 of 2 Fort Randall MUR FINAL_ REFERENCE DRAWINGS 6-25-20.pdf PDF
Part 2 of 2 Fort Randall MUR FINAL_ REFERENCE DRAWINGS 6-25-20.pdf PDF
W9128F21R0005_Summary of Changes_Draft to Final Solicitation.pdf PDF
Fort Randall MUR FINAL_COLOR_ Contract Drawings Review 12-15-20 REDUCED.pdf PDF
Ft Randall Major Unit Rehab W9128F21R0005 Contract Specs .pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Cavitation scaffolding set up

1. Unwater and place Maintenance clearances on the unit.

2. Put brackets on the doors going into the draft tube door slots make sure you install bolts into door bolt holes.

3. Put I-beams through door openings onto brackets, then bolt them down. (You need a rope to pull items from one side to the other).

4. Install a sling on the stay vanes. (fall protection tie off point)

5. Put fall protection harness on to hook into the slings.

6. Put deckplate on top of beams and bolt down. (You will need a rope to pull decking across the I-beams.)

7. Install I-Beams in through the door opening for hand rails and bolt them down.

8. Start putting up scaffolding has numbers and paint on it for installation. Two people are needed in side on walk way and two people outside handing items in.

9. Start installing scaffolding on the upstream side, then work your way to the downstream side. I-beams and hooks need to be put up in the groove on the runner. Ensure chains are not twisted.

Install Decking at the same time you are putting the I-beams up make sure you install the bolts as you put it together.

10. Once you have all the scaffolding up you need to put in 4 wedges so the scaffolding doesn’t move.

11. Put in the steps that are going into the draft tube and to the scaffolding.

12. Put the Lights in now.

13. Move wicket gates to position so a person can get though.

14. Put the wicket gates on just about 35%

15. Put a sealer around the wicket gates and the runner opening.

16. Start putting in the welders, air hoses, cords

File details come from the government source that posted it. Updated .