9104134 StandoffInsulator.pdf

PDF 351 KB Posted

Attached to
Fort Randall Major Unit Rehabilitation Project
Solicitation number
W9128F21R0005
Issued by

About this file

This document provides details for a federal contract solicitation for the Fort Randall Major Unit Rehabilitation Project. The solicitation closes on March 25, 2021 at 2pm Central time and is unrestricted and open to both large and small business participation. An updated site visit will be held on January 12-13, 2021 beginning at 9am, with potential bidders limited to a single day on site due to COVID-19 restrictions. Contractors must RSVP with preferred date and non-US citizen attendee information by specified deadlines. During the site visit, one unit will be available for turbine inspection with maintenance platform installed, and the generator housing will have components removed for inspection and measurements. Interested contractors must make reservations with and submit required information to the specified Army Corps of Engineers point of contact. The soliciting agency is the Department of the Army Corps of Engineers Omaha District.

View the file

Other files

File Type Posted
Am0006 W9128F21R0005.pdf PDF
Am0005 W9128F-21-R-0005.pdf PDF
Am0004 W9128F-21-R-0005.pdf PDF
9040123 Penstock 16 inch.JPG JPG image
9040124 Air Depression Diaphragm Valve 1.jpg JPG image
9045637 Drawings_Headcover Access Inquiry.pdf PDF
9040124 Air Depression Diaphragm Valve 2 .jpg JPG image
9040123 Penstock 12 inch valve.JPG JPG image
Am0003 W9128F21R0005 FR MUR.pdf PDF
20210223_093629.jpg JPG image
20210223_091749.jpg JPG image
coc lab_250047.pdf PDF
0250047-PLM.pdf PDF
20210223_093204.jpg JPG image
20210223_092341.jpg JPG image
TMP_Existing Design_Component Overview.pdf PDF
Pages from Generator Test Report - Westinghouse.pdf PDF
TMP_Existing Design_Procedure.pdf PDF
TMP_Existing Design_Drawings.pdf PDF
Waterway Drawings.pdf PDF
Am0002 - W9128F21R0005.pdf PDF
195215A Pressure Tank.pdf PDF
195214A Pressure Tank.pdf PDF
18-C-5325_Stator Coil Windings.pdf PDF
AM0001_W9128F21R0005 - FR MUR.pdf PDF
Water Quality - Fort Randall.pdf PDF
12_13 Jan 21 Fort Randall Site Visit Presentation.pdf PDF
Site Visit Sign-In_13 Jan 21_FR Major Rehab.pdf PDF
Site Visit Sign-In_12 Jan 21_FR Major Rehab.pdf PDF
Part 1 of 2 Fort Randall MUR FINAL_ REFERENCE DRAWINGS 6-25-20.pdf PDF
Part 2 of 2 Fort Randall MUR FINAL_ REFERENCE DRAWINGS 6-25-20.pdf PDF
W9128F21R0005_Summary of Changes_Draft to Final Solicitation.pdf PDF
Fort Randall MUR FINAL_COLOR_ Contract Drawings Review 12-15-20 REDUCED.pdf PDF
Ft Randall Major Unit Rehab W9128F21R0005 Contract Specs .pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ii ,1 ii

!I

I jl i� t

-,.-----,.----'\---t------t----r'--<( �

U') 0 N 0 <O 0 a:i ,.; II)

0 0 0

-�0

XIXXXXX·XX

CD

d:i z i=

UJ

Cl)

...... .t..:., ._._....._, __ ......., _____ �l C

M a, a, CD

&l

....I t "A"

7' DIA

[178rrirri DIA)

DESCRIPTION

HIGH-STRENGTH BUS INSULATOR

DIMENSIONS

HEIGHT 7.375' C187r,r,J

DIAMETER 7.00' [178MMJ

BOLT CIRCLE DIA. 3.00' [76MMJ

LEAKAGE DISTANCE 13.25' [337MMJ

MECHANICAL VALUES

TENSILE 7, 900LBS [35kNJ COMPRESSION 50,000LBS [222kNJ CANTILEVER 3,l00LBS Cl4kNJ TORSION 17,000LBS [76kNJ

ELECTRICAL VALUES

DRY w'ITHST AND <1 MIN) S0kV DRY FLASHOVER 50kV DE\./ \./ITHSTAND <10 SEC> 50kV DE\./ FLASHOVER S0kV IMPULSE \./ITHST AND + ll0kV IMPULSE w'ITHST AND - ll0kV

NOTES1

(4) 1/2-13 TH'D HOLES

x 11/16' GOOD THREAD

3' C76r,rriJ D.B.C.

3/4-10 BOH HOLE

x 11/16' GOOD THREAD

VIE\./ 'A-A'

<TYP. TOP & BOTTOM)

UNGLAZED FIRING SURFACE

D INSULATOR MATERIAL = \./ET PROCESS PORCELAIN

w'ITH ANSI #70 LIGHT GRAY GLAZE

2) INSERT MATERIAL = GALVANIZED STEEL

PART# MI-HSBll0

HIGH STRENGTH PORCELAIN BUS INSULATOR

15kV 110BIL