0250047-PLM.pdf

PDF 90 KB Posted

Attached to
Fort Randall Major Unit Rehabilitation Project
Solicitation number
W9128F21R0005
Issued by

About this file

This solicitation is for the Fort Randall Major Unit Rehabilitation Project. The Government is seeking bids for rehabilitation of units at Fort Randall Dam to close on March 25, 2021. An updated site visit will be held on January 12-13, 2021 with COVID-19 restrictions limiting attendees to a single day and restricting total numbers if needed. Non-US citizens must be identified by December 17, 2020 for approval. The site visit will include a dewatered unit and open penstock for inspection as well as accessible generator components. Interested contractors must RSVP for the site visit with Robin Puskar by December 22, 2020. The solicitation is unrestricted and open to both large and small businesses.

View the file

Other files

File Type Posted
Am0006 W9128F21R0005.pdf PDF
Am0005 W9128F-21-R-0005.pdf PDF
9104134 StandoffInsulator.pdf PDF
Am0004 W9128F-21-R-0005.pdf PDF
9040123 Penstock 16 inch.JPG JPG image
9040124 Air Depression Diaphragm Valve 1.jpg JPG image
9045637 Drawings_Headcover Access Inquiry.pdf PDF
9040124 Air Depression Diaphragm Valve 2 .jpg JPG image
9040123 Penstock 12 inch valve.JPG JPG image
Am0003 W9128F21R0005 FR MUR.pdf PDF
20210223_093629.jpg JPG image
20210223_091749.jpg JPG image
coc lab_250047.pdf PDF
20210223_093204.jpg JPG image
20210223_092341.jpg JPG image
TMP_Existing Design_Component Overview.pdf PDF
Pages from Generator Test Report - Westinghouse.pdf PDF
TMP_Existing Design_Procedure.pdf PDF
TMP_Existing Design_Drawings.pdf PDF
Waterway Drawings.pdf PDF
Am0002 - W9128F21R0005.pdf PDF
195215A Pressure Tank.pdf PDF
195214A Pressure Tank.pdf PDF
18-C-5325_Stator Coil Windings.pdf PDF
AM0001_W9128F21R0005 - FR MUR.pdf PDF
Water Quality - Fort Randall.pdf PDF
12_13 Jan 21 Fort Randall Site Visit Presentation.pdf PDF
Site Visit Sign-In_13 Jan 21_FR Major Rehab.pdf PDF
Site Visit Sign-In_12 Jan 21_FR Major Rehab.pdf PDF
Part 1 of 2 Fort Randall MUR FINAL_ REFERENCE DRAWINGS 6-25-20.pdf PDF
Part 2 of 2 Fort Randall MUR FINAL_ REFERENCE DRAWINGS 6-25-20.pdf PDF
W9128F21R0005_Summary of Changes_Draft to Final Solicitation.pdf PDF
Fort Randall MUR FINAL_COLOR_ Contract Drawings Review 12-15-20 REDUCED.pdf PDF
Ft Randall Major Unit Rehab W9128F21R0005 Contract Specs .pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Asbestos Detected

Layer Name / Sample Description

Lab ID Sample Location

Bulk Asbestos Analysis by Polarized Light Microscopy

Non-Asbestos Constituents

Laboratory Report

0250047

NVLAP#101926-0

Client ID

Client:

Address: 909 E. 50TH STREET NORTH

SIOUX FALLS, SD 57104

GEOTEK ENGINEERING

Date Received: 02/26/2021

03/01/2021Date Analyzed:

Job# / P.O. #:

EMC LABS, INC.

Collected: 02/23/2021

EPA Method: Project Name: FT. RANDALL DAM

Submitted By: JERRY ZUTZAddress:

Collected By:

9830 S. 51st Street, Suite B109, Phoenix, AZ 85044 Phone: 800-362-3373 or 480-940-5294 - Fax: (480) 893-1726

03/02/2021Date Reported:

EPA 600/R-93/116

Asbestos Type

Fibrous Glass Cellulose Fiber

NoExciter, Red/ Black/Yellow None Detected0250047-001 UNIT 2 MAIN

EXCITER001

85% 10%

Carbonates Gypsum Binder/Filler

5%

Cellulose FiberNoExciter, Red/ Black/Yellow None Detected0250047-002 UNIT 2 PILOT

EXCITER002

85%

Carbonates

15%

Fibrous GlassNoExciter, Red/ Black/Yellow None Detected0250047-003 UNIT 9 MAIN

EXCTIER003

95%

Carbonates Quartz

5%

Cellulose FiberNoExciter, Red/ Black/Yellow None Detected0250047-004 UNIT 8 PILOT

EXCITER004

85%

Carbonates

15%

Analyst - Matt Kettler Signatory - Lab Director - Kurt Kettler

Distinctly stratified, easily separable layers of samples are analyzed as subsamples of the whole and are reported separately for each discernible layer. All analyses are derived from calibrated visual estimate and measured in area percent unless otherwise noted. The report applies to the standards or procedures identified and to the sample(s) tested. The test results are not necessarily indicated or representative of the qualities of the lot from which the sample was taken or of apparently identical or similar products, nor do they represent an ongoing quality assurance program unless so noted. These reports are for the exclusive use of the addressed client and that they will not be reproduced wholly or in part for advertising or other purposes over our signature or in connection with our name without special written permission. The report shall not be reproduced except in full, without written approval by our laboratory. The samples not destroyed in testing are retained a maximum of thirty days. The laboratory measurement of uncertainty for the test method is approximately less than 1 by area percent.

Accredited by the National Institute of Standards and Technology, Voluntary Laboratory Accreditation Program for selected test method for asbestos. The accreditation or any reports generated by this laboratory in no way constitutes or implies product certification, approval, or endorsement by the National Institute of Standards and Technology. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Polarized Light Microscopy may not be consistently reliable in detecting asbestos in floor coverings and similar non-friable organically bound materials.

File details come from the government source that posted it. Updated .