PHASE 2 - MAIN OPERATIONS 60140804P2
C2F COMPLEX
2.1.6.2 Latch and Pull
Latch and pull shall be a combination rubber-faced door strike and keeper equipped with emergency access.
2.1.6.3 Coat Hooks
Coat hooks shall be combination units with hooks and rubber tipped pins.
2.2 PARTITION PANELS AND DOORS
Provide partition panels and doors not less than 1 inch thick with face sheets not less than 0.0396 inch thick.
2.2.1 Toilet Enclosures
Conform toilet enclosures to CID A-A-60003, Type I, Style A, floor supported. Furnish width, length, and height of toilet enclosures as shown. Provide a width of 1 inch. Finish surface of panels shall be stainless steel (5WL finish); water resistant; graffiti resistant;
non-absorbent. Enclosures shall contain a minimum of 50 percent recycled steel, with a minimum of 21 percent post-consumer recycled steel. See Section 01 33 29 LEED(tm) DOCUMENTATION for cumulative total recycled content requirements. This item may contain post-consumer or post-industrial recycled content. Reinforce panels indicated to receive toilet paper holders or grab bars for mounting of the items required.
Provide grab bars to withstand a bending stress, shear stress, shear force, and a tensile force induced by 250 lbf. Grab bars shall not rotate within their fittings.
2.2.3 Urinal Screens
Conform urinal screens to CID A-A-60003, Type III, Style A, wall hung.
Provide finish for surface of screens as stainless steel (Finish as indicated); water resistant; graffiti resistant; non-absorbent. Screens shall contain a minimum of 50 percent recycled steel, with a minimum of 21 percent post-consumer recycled steel. See Section 01 33 29 LEED(tm) DOCUMENTATION for cumulative total recycled content requirements. This item may contain post-consumer or post-industrial recycled content.
Furnish width and height of urinal screens as shown. Provide thickness of 1 inch. Secure wall hung urinal screens with a minimum of three wall stirrup brackets 42 inch long, continuous flanges. Fabricate screens from the same types of panels and pilasters as the toilet partitions. Use corrosion-resistant steel fittings and fasteners.
2.3 FLOOR-ANCHORED PARTITIONS
Pilasters shall be not less than 1-1/4 inch thick with face sheets not less than 0.0635 inch thick. Provide anchoring device at the bottom of the pilaster consisting of a steel bar not less than 1/2 by 7/8 inch welded to the reinforced face sheets and having not less than two 3/8 inch round anchorage devices for securing to the floor slab. Provide anchorage devices complete with threaded rods, expansion shields, lock washers, and leveling-adjustment nuts. Trim piece at the floor shall be 3 inch high and fabricated from not less than 0.030 inch thick corrosion-resistant steel.
2.4 PILASTER SHOES
Provide shoes at pilasters to conceal floor-mounted anchorage. Pilaster
SECTION 10 21 13 Page 5