About this file

W9128A-15-B-0001 AM-0006 Sheet A-416

View the file

Other files

File Type Posted
15b1-bid_abstract.pdf PDF
C2F-am8__27_10_00.pdf PDF
15b1_am8_10june15.pdf PDF
C2F_am7_S-123.pdf PDF
15b1_am7_9june15.pdf PDF
C2F_am7_IG202.pdf PDF
C2F-am7_01_45_00.pdf PDF
C2F-am7_09_69_13.pdf PDF
C2F_am7_A-433.pdf PDF
C2F_am7_A-431.pdf PDF
C2F_am7_IN601.pdf PDF
C2F_am7_IG601.pdf PDF
C2F_am7_EP_Plans.pdf PDF
C2F_am7_10_21_13.pdf PDF
C2F-am7__09_90_00.pdf PDF
C2F_am6_A-122.pdf PDF
C2F_am6_TS101.pdf PDF
C2F_am6_A-421.pdf PDF
C2F_am6_A-422.pdf PDF
15b1_am6_5june15.pdf PDF
C2F_am5_ES110.pdf PDF
C2F_am5_EP702.pdf PDF
C2F_am5__09_69_13.pdf PDF
C2F_am5_A-622.pdf PDF
C2F_am5_A-621.pdf PDF
15b1_am5_3june15.pdf PDF
C2F_am5_IN601.pdf PDF
C2F_am5_08_34_73.pdf PDF
C2F_am5_A-655.pdf PDF
15b1_am4_29may15.pdf PDF
15b1_am3_22may15.pdf PDF
15b1_am2_21may15.pdf PDF
Amend_2_-_PH2_-_Civil_Site_Sheets.pdf PDF
Amend_2_-_PH2_-_Electrical_Sheet.pdf PDF
Amend_2_-_01_90_00.pdf PDF
Amend_2_-_01_57_20.pdf PDF
15b1_am1_13may15.pdf PDF
Dwgs_V3_a2.pdf PDF
Dwgs_V2_a10.pdf PDF
Dwgs_V2_a11.pdf PDF
Dwgs_V2_a12.pdf PDF
Dwgs_V1_a13.pdf PDF
Dwgs_V2_a2.pdf PDF
Dwgs_V1_a4.pdf PDF
Dwgs_V4_a3.pdf PDF
Dwgs_V2_a3.pdf PDF
Dwgs_V2_a7.pdf PDF
Specs_V2.pdf PDF
Dwgs_V1_a3.pdf PDF
Dwgs_V3_a6.pdf PDF
Show 40 more

Latest 50 of 133 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C O

M M

O

N W

EALTH OF V

IR

G

IN

IA

A422

C2

A422

C2

REVEAL, TYP

173’-0"

5TH FIN. FL

156’-0"

4TH FIN. FL

139’-0"

3RD FIN. FL

122’-0"

2ND FIN. FL

188’-11"

6TH FIN. FL

XFXA XB XDXC XE

XFXA XB XDXC XE

STAIR

N2

HDR, TYP

WALL MTD

CONC BEAM, TYP

INFILL GDR ON

STAIR

N2

CONC BEAM, TYP

INFILL GDR UNDER

STAIR, TYP

GDR AT

LANDING, TYP

GDR AT INTMD

LIGHTING, TYP

HDR WITH LED

LIGHTING, TYP

HDR WITH LED

LANDING, TYP

GDR AT MAIN

E

Q L R

IS

E R

S E

Q L R

IS

E R

S E

Q L R

IS

E R

S E

Q L R

IS

E R

S E

Q L R

IS

E R

S E

Q L R

IS

E R

S E

Q L R

IS

E R

S E

Q L R

IS

E R

S

PNT

PLUMBING,

TYP, SEE

LEADER

DRAIN

HPT

188’-11"

6TH FIN. FL

173’-0"

5TH FIN. FL

156’-0"

4TH FIN. FL

139’-0"

3RD FIN. FL

122’-0"

2ND FIN. FL

E

Q L R

IS

E R

S E

Q L R

IS

E R

S E

Q L R

IS

E R

S E

Q L R

IS

E R

S E

Q L R

IS

E R

S E

Q L R

IS

E R

S E

Q L R

IS

E R

S E

Q L R

IS

E R

S

XF XE XD XC XB XA

XF XDXE XAXBXC

LANDING, TYP

GDR AT INTMD

LIGHTING, TYP

HDR WITH LED

CONC BEAM, TYP

INFILL GDR UNDER

CONC BEAM, TYP

INFILL GDR ON

LIGHTING, TYP

HDR WITH LED

LANDING, TYP

GDR AT MAIN

HDR, TYP

WALL MTD

STAIR, TYP

GDR AT

PNT

SEE PLUMBING,

LEADERS TYP,

DRAIN

HPT

1 2 4 5

A

B

C

D

US Army Corps of Engineers

Honolulu District

GRAPHIC SCALES

M a rk

D e s c ri p ti o n

D a te

C h k d

A p p r

M a rk

A p p r

C h k d

D a te

D e s c ri p ti o n

D e s ig n e d b y

D a te

R e v

S u b m it te d b y

F il e n a m e

C h ie f, D ra w in g c o d e

P lo t d a te lo t s c a le

Sheet number:

Location code:

Drawing no.

U .S

A R

M Y E

N G

IN

E E

R D

IV

IS

IO

N

A C

IF

IC

O

C E

N

H

N

O L

U L

U

H A

W

II

C

M M

A N

D A

N D C

O N

T R

O L F

A C

IL

IT

Y

C F

:1

141-82-004

-8

-0

F O

R T S

H A

F T

E R

O ’A

H U

H A

W A

II

C h e c k e d b y w w w .a e c o m .c o m

R O

A N

O K

E

V A H

O N

O L

U L

U

H I

A E

C O

M

PHASE 2

D ra w n b y

P H

A S

E M

A

IN

O

P E

R A

T

IO

N S

M R

B

/1

/2

ME OR UNDER MY SUPERVISION

THIS WORK WAS PREPARED BY

C O

M M

O

N W

EALTH OF V

IR

G

IN

IA

ARCHITECT

CORY LEE BONHAM

Lic. No. 014056

FOR OFFICIAL USE ONLY

FOR OFFICIAL USE ONLY

Sheet of260 3/16" = 1’-0"

A416

STAIR N2 - SECTIONA3

C M

G

C L

B

S T

A

IR

N

A416

R B

T

C F

M O

P -A -4

NOTES THIS SHEET

S E

C T

IO

N S

0 16’

SCALE: 3/16"=1’-0"

4’ 8’

A416

A1 3/16" = 1’-0"

STAIR N2 - SECTION

SECTIONS FOR CLARITY.

SQUARE MESH INFILL AT GUARDRAILS NOT SHOWN ON 8.

CLARITY.

CENTER HANDRAIL NOT SHOWN ON SECTIONS FOR 7.

OF IBC SECTION 721.

RATED CONSTRUCTION AS PER THE REQUIREMENTS

STAIR N2 ROOF CONSTRUCTION IS TO BE 1HR FIRE 6.

OF IBC SECTION 721.

RATED CONSTRUCTION AS PER THE REQUIREMENTS

STAIR N2 STRUCTURAL FRAME IS TO BE 2HR FIRE 5.

REFER TO SH A525 DET D3 FOR TYP STAIR N2 REVEAL.4.

CAST IN PLACE CONCRETE ROOF.

DETAILS AND DIMENSIONS FOR THE ARCHITECTURAL

REFER TO SHEETS S312 AND S402 FOR FURTHER 3.

FINISH.

AT STAIR N2. WALKING SURFACE TO HAVE A BROOM

PROVIDE CAST IN PLACE ARCHITECTURAL CONCRETE 2.

GUARDRAIL AND HANDRAIL DETAILS.

REFER TO SH A422 FOR STAIR N2 TYPICAL STAIR, 1.

A

M -0

-0

-1

C

L B

T C

L