A32_TechnicalExhibits-5.6.xlsx
XLSX spreadsheet 531 KB Posted
- Solicitation number
- W91249-19-R-0019
About this file
This document contains technical exhibits for the Fort Gillem Enclave Base Operations and Maintenance Support Services contract opportunity. It includes backflow device listings, communication manhole locations, emergency generator details, demand maintenance order reports, preventative maintenance look ahead reports, utility line demarcations, and electrical and natural gas distribution system inventories for Fort Gillem. The solicitation is identified as W91249-19-R-0019 and seeks base operations and support services for the Gillem Enclave. The contracting agency is the Department of the Army Materiel Command Mission and Installation Contracting Command at Fort Eustis. Products and services required include facilities maintenance, utilities operation and maintenance, custodial services, integrated solid waste management, integrated pest management, and other base support functions. The response date is not specified but the incumbent contractor is also not identified.
View the file
Other files
Show 40 more
Latest 50 of 98 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Backflow Inventory
| Attachment 5.6 02 Backflow Device Listing | |||||
| GILLEM ENCLAVE BACKFLOW LISTING | |||||
| Building | Building Name | Program | QUANTITY | SIZE | MANUFACTURER |
| 608 Ser Line | GANG READINESS CENTER | Containment | 1 | 3" | Watts RPZ |
| 608 Fire Line | GANG READINESS CENTER | Containment | 1 | 6" | Ames DCV |
| 700 Ser Line | USACIL Crime Lab Storage Facility | ||||
| 700 Ser Line | USACIL Crime Lab Storage Facility | Isolation | 1 | 3/4" | Watts RPZ |
| 701 Ser Line | VISTOR CONTROL CENTER | Containment | 1 | 1.5" | Wilin Zurn DCV |
| 702 Ser Line | ACCCESS CONTROL POINT | Containment | 1 | 1.5" | Wilkin Zurn RPZ |
| 714 Ser Line | GILLEM ENCLAVE HQS | Containment | 1 | 2" | Watts DCV |
| 718 Ser Line | 723RD AND 184TH EOD HQS | Containment | 1 | 2.5" | Watts DCV |
| 718 Make up | 723RD AND 184TH EOD HQS | Isolation | 1 | 1" | Watts RPZ |
| 720 | MEPS FACILITY | Isolation | 1 | 1" | Wilkins Zurn DCV |
| 760 | New Dial Control Center (DCO) | Containment | 1 | ||
| 838 | CID FRAUD TEAM | Containment | 1 | 1.5" | Wilkins Zurn RPZ |
| 839 Ser Line | USARC INTEL SUPPORT TRNG FAC | Containment | 1 | 2.5" | Watts DCV |
| 839 Makeup | USARC INTEL SUPPORT TRNG FAC | Isolation | 1 | 3/4" | Watts RPZ |
| 839 Makeup | USARC INTEL SUPPORT TRNG FAC | Isolation | 1 | 3/4" | Watts RPZ |
| 900 Ser Line | USARC ADMIN GEN PURPOSE | Containment | 1 of 2 | 4" | Watts RPZ |
| 900 Ser Line | USARC ADMIN GEN PURPOSE | Containment | 2 of 2 | 4" | Ames RPZ |
| 900 Fire Line | USARC ADMIN GEN PURPOSE | Containment | 1 | 4" | Ames DCV |
| 900 Makeup | USARC ADMIN GEN PURPOSE | Isolation | 1 | 3/4" | Watts RPZ |
| 900 Makeup | USARC ADMIN GEN PURPOSE | Isolation | 1 | 1" | Watts RPZ |
| 905 Ser Line | VEHICLE MAINT FACILITY | Containment | 1 | 2.5" | Watts DCV |
| 905 Fire Line | VEHICLE MAINT FACILITY | Containment | 1 | 6" | Ames DCV |
| 910 Ser Line | MEDICAL BATTALION LOGISTICS | Containment | 1 | 2" | Watts RPZ |
| 910 Makeup | MEDICAL BATTALION LOGISTICS | Containment | 1 | 3/4" | Watts RPZ |
| 910 Fire Line | MEDICAL BATTALION LOGISTICS | Containment | 1 | 4" | Ames DCV |
| 913 Ser Line | USARC MEDICAL WAREHOUSE | Containment | 1 | 2" | Watts RPZ |
| 913 Fire Line | USARC MEDICAL WAREHOUSE | Containment | 1 | 6" | Ames DCV |
| 913 Makeup | USARC MEDICAL WAREHOUSE | Isolation | 1 | 1" | Watts RPZ |
| 929 | ELEV FIRE PROTECTION WATER TANK | ||||
| 931 Ser line | DEFENSE FORENSIC SCIENCE CENTER | Containment | |||
| 931 Fire line | DEFENSE FORENSIC SCIENCE CENTER | Containment | 1 | 4" | Ames DDCV |
| 931 Makeup | DEFENSE FORENSIC SCIENCE CENTER | Isolation | 1 | 3/4" | Watts RPZ |
| T925 | DFSC LEASED TRAILER | ||||
| T926 | DFSC LEASED TRAILER | ||||
| T710 | DOUBLE WIDE TRAILER | ||||
| Distribution Sys | On Fire Line @ DFSC Mobil Lab Comp | Containment | 1 | 10" | Watts DDCV |
USAG FORT GORDON - GILLEM ENCLAVE
FOUO-Source Selection Sensitive - See FAR 2.101 and FAS 3.104
Comm Manholes
| Attachment 5-6 - 03 |
| COMMUNICATION MANHOLE LISTING |
MANHOLE NUMBER APPROXIMATE LOCATION
| MH 931 | Between and east of Bldgs 929/931 |
| MH 929 | N 31st St, near N "R" St. |
| MH 1 | N 31st St, between Bldgs 720 & 910 |
| MH 2 | N 31st St, between Bldgs 720 & 910 |
| MH 3 | N 31st St, in front of Bldg 925 |
| MH 4 | North of MH 3 |
| MH 5 | Northeast of MH 4 |
| MH 106-A | N 31st St, between Bldgs 720 & 910 |
| MH 925 | N 31st St, in front of Bldg 925 |
| MH 900 | West of Bldg 900, off Hood Ave |
| MH 902 | N 31st St & Hood Ave. |
| MH 107-A | N 31st St & Hood Ave. |
| MH 936 | East of N 37th St. |
| MH 941 | Northeast of MH 938 |
| MH 941-A | Northwest of MH 941 |
| MH 839 | East of Bldg 839 |
| MH 839-A | West of Bldg 839 |
| MH 720 | Northeast of Bldg 720 |
| MH 720-A | Behind of Bldg 720 |
| MH 814 | In front of Bldg 838 |
| MH 106-A | West of Bldg 714 |
| MH 736 | In front of Bldg 760 |
| MH 105 | East of Bldg 714 |
| MH 808 | Hood Ave, souheas of Bldg 714 |
| MH 104-A | Near main gate |
| MH 760 | Northeast of Bldg 760 on N 26th St. |
| MH 757 | N "K" Ave, near N 22nd St. |
| MH 610-C | N 20th St & N "K" Ave. |
| MH 610-B | Near Bldg 607-Pole Barn |
Generators
| Attachment 5.6 - 04 | |||
| GILLEM ENCLAVE EMERGENCY GENERATORS | |||
| Diesel | Nat Gas | ||
| Building Number | Description | ||
| 608 | 500kw Taylor Generator M/N TD500 | X | |
| 702 | 300 KW Cummings | X | |
| 760 | 180 KW MTU On Site Energy | X | |
| 839 | 750 KW Caterpillar | X | |
| 912 | Generac Power System 4656705 QT080466NSN NGAS 80 GENERAC 120/208 | X | |
| 931 | 500 KW Kohler | X |
DMO Perf Rep Template
| Attachment 5.6 - 05 | |||||||||||
| Open Demand Maintenance Orders | |||||||||||
| with Facility Category - as of 03 October 2012 | |||||||||||
| GFEBS# | FacNo | Pri | Status | Created | Shop | Task | Task Desc | Target Comp Date | SERVICE ORDER STATUS ON 10/04/12 | EDD VERIFIED BY SUPPLY ADMIN (10/04/12) | |
| 1 | 100001341179 | 29705 | 2 | WMATL | 9/24/2012 1:52:21 PM | MRS | 039A | E! 29705 rm 102 washer will not |
power on, sn HL20655317 1352 24 sep 12 kr
| 10/10/2012 1:52:21 PM | WMATL | 11/16/12 | ||||||
| 2 | 100001341180 | 29705 | 2 | WMATL | 9/24/2012 1:53:45 PM | MRS | 039A | E! 29705 rm 202 washer door |
will not stay closed, sn HL20546529 1354 24 sep 12 kr
| 10/10/2012 1:53:45 PM | WMATL | 11/16/12 | ||||||
| 3 | 100001351910 | 24412 | 2 | SHP | 9/24/2012 10:55:17 AM | MRS | 0003 | (R)24412 Rm 322 paint peeling |
on ceiling
| 10/10/2012 10:55:17 AM | SHP | |||||||
| 4 | 100001352165 | 00317 | 2 | SHP | 9/26/2012 7:33:12 AM | ECS | 036I | (R) 317/ Please refer to Akima |
per Micah: CCV valve stem is not connected to the CHW line on
AHU3; UMCS/79893
| 10/10/2012 7:33:12 AM | SHP | |||||||
| 5 | 100001351427 | 00317 | 2 | TSFM | 9/17/2012 2:54:18 PM | MRS | 0017 | (R)E! 317 attn David W D24 |
ceiling fan inop 1454 17 sep 12 kr
| 10/10/2012 7:54:28 AM | TSFM | |||||||
| 6 | 100001351434 | 00317 | 2 | TSFM | 9/17/2012 2:55:28 PM | MRS | 0017 | (R)E! 317 attn David W F21 |
ceiling fan inop 1454 17 sep 12 kr
| 10/10/2012 7:54:28 AM | TSFM | |||||||
| 7 | 100001351439 | 00317 | 2 | TSFM | 9/17/2012 2:56:01 PM | MRS | 0017 | (R)E! 317 attn David W D24 |
ceiling fan inop 1454 17 sep 12 kr
| 10/10/2012 7:54:28 AM | TSFM | |||||||
| 8 | 100001353295 | 00315 | 2 | SHP | 10/1/2012 10:35:00 AM | MRS | 003B | 315 B22 repair & paint walls |
1035 01 oct 12 kr
| 10/15/2012 10:35:00 AM | SHP | |||||||
| 9 | 100001353298 | 00315 | 2 | SHP | 10/1/2012 10:36:00 AM | MRS | 003B | 315 B23 repair & paint walls |
1036 01 oct 12 kr
| 10/15/2012 10:36:00 AM | SHP | |||||||
| 10 | 100001350171 | 25412 | 2 | SHP | 9/30/2012 10:33:00 AM | MRS | 003G | *ESO 25412 outside door inop, |
2nd flr --poc stated fire hazard 1033 30 sep 12 kr
| 10/15/2012 4:22:14 PM | SHP | |||||||
| 11 | 100001353250 | 24413 | 2 | SRESE | 10/2/2012 10:08:31 AM | MRS | 007C | 24413/Rm 125 tub leaking |
through wall into rm
| 10/16/2012 10:08:31 AM | WMATL | 10/5/12 | ||||||
| 12 | 100001353546 | 00315 | 2 | SHP | 10/2/2012 12:48:59 PM | MRS | 0003 | 315 attn Carl B13 cut & rpr duct |
work 1249 02 oct 12 kr
| 10/16/2012 12:48:59 PM | SHP | |||||||
| 13 | 100001353547 | 00315 | 2 | SHP | 10/2/2012 12:50:12 PM | MRS | 0003 | 315 attn Carl D23 cut & rpr duct |
work 1249 02 oct 12 kr
| 10/16/2012 12:50:12 PM | SHP | |||||||
| 14 | 100001353818 | 28433 | 2 | SHP | 10/2/2012 2:05:42 PM | ECS | 039Q | 28433 rm 301 refrig leaking |
water and starting to mildew pr poc 1406 02 oct 12 kr
| 10/16/2012 2:05:42 PM | SHP | |||||||
| 15 | 100001353989 | 25716 | 2 | SHP | 10/2/2012 3:56:40 PM | MRS | 002F | 25716 chk overhangs above |
windows on front side of bldg for cracks to be sure they are safe 1557 02 oct 12 kr
| 10/16/2012 3:56:40 PM | SHP | |||||||
| 16 | 100001353990 | 00315 | 2 | SHP | 10/2/2012 4:02:44 PM | ECS | 039Q | E! 315 E33 replace refrig pr |
aprvd memo from Pat Arthur 1603 02 oct 12 kr
| 10/16/2012 4:02:44 PM | SHP | |||||||
| 17 | 100001353991 | 00315 | 2 | SHP | 10/2/2012 4:09:08 PM | MRS | 001B | E! 315 F24 rpl core & issue 2 |
keys - aprvd by Pat Arthur 1609 02 oct 12 kr
| 10/16/2012 4:09:08 PM | SHP | |||||||
| 18 | 100001352114 | 25703 | 2 | SHP | 10/2/2012 9:35:54 AM | MRS | 006E | 25703 rm 129 exhaust fan inop |
| 10/16/2012 9:35:54 AM | SHP | |||||||
| 19 | 100001356077 | 25708 | 2 | SHP | 10/3/2012 10:06:51 AM | MRS | 007B | E! 25708, Rm# 241, Sink 5 & 6 |
is clogged, also sink 6 water is deactivated. 10/03/12 LM
| 10/17/2012 10:06:51 AM | SHP | |||||||
| 20 | 100001356434 | 25716 | 2 | SHP | 10/3/2012 12:54:46 PM | ECS | 036D | 25716/ Refer to Akima per Albert, |
AHU3E is leaking water into room.; UMCS WO 80084
| 10/17/2012 12:54:46 PM | SHP | |||||||
| 21 | 100001357586 | 25413 | 2 | SHP | 10/3/2012 2:10:42 PM | MRS | 0001 | 25413 attn 224 reset locks to |
default codes 1411 03 oct 12 kr
| 10/17/2012 2:10:42 PM | SHP | |||||||
| 22 | 100001357588 | 28410 | 2 | SHP | 10/3/2012 2:22:21 PM | MRS | 007G | 28410, Rm# 211, Per POC " |
toilet does not flush everything down, sometimes tissue comes back up. 10/03/12 LM
| 10/17/2012 2:22:21 PM | SHP | |||||||
| 23 | 100001357590 | 28425 | 2 | SHP | 10/3/2012 2:22:34 PM | ECS | 0036 | 28425, A/C unit leaking in |
Lounge Area on 1st deck (Floor) per poc. 10/03/12 LM
| 10/17/2012 2:22:34 PM | SHP | |||||||
| 24 | 100001354924 | 19735 | 2 | SHP | 10/3/2012 7:41:56 AM | ECS | 036D | 19735/ Refer to Akima per David |
P. - AHU1 VAV212 (Rm 3205) RHV not moving, good UMCS.;
UMCS WO 80058
| 10/17/2012 7:41:56 AM | SHP | |||||||
| 25 | 100001354922 | 24406 | 2 | SHP | 10/2/2012 1:37:33 PM | ECS | 0036 | E! 24406 Rm 234 No AC |
| 10/17/2012 7:55:21 AM | SHP | |||||||
| 26 | 100001354859 | 24407 | 2 | SHP | 10/2/2012 10:04:20 AM | ECS | 0036 | 24407 No AC rm 259 |
| 10/17/2012 7:55:58 AM | SHP | |||||||
| 27 | 100001355282 | 00315 | 2 | SHP | 10/3/2012 9:10:33 AM | MRS | 039Q | 315 C module dayrm fridge |
making noise per POC
| 10/17/2012 9:10:33 AM | SHP | |||||||
| 28 | 100001355285 | RBK09 | 2 | SHP | 10/3/2012 9:21:49 AM | ECS | 0036 | E! RBK09,Rm# 103,131, 132, |
146, 203, 209, 212, 239, 241 & 246, Air conditioner. 10/03/12 LM
| 10/17/2012 9:21:49 AM | SHP | |||||||
| 29 | 100001355289 | RBK09 | 2 | SRESE | 10/3/2012 9:44:15 AM | MRS | 007D | E! RBK09, Rm# 118 (Bathrm |
Toilet's), Two urinals inop.
10/03/12 LM
| 10/17/2012 9:44:15 AM | WMATL | 10/12/12 | ||||||
| 30 | 100001355290 | RBKS1 | 2 | SHP | 10/3/2012 9:48:29 AM | MRS | 022D | E! RBKS1, Ice machine inop. |
10/03/12 LM
| 10/17/2012 9:48:29 AM | SHP | |||||||
| 31 | 100001356073 | 25708 | 2 | SHP | 10/3/2012 9:55:52 AM | MRS | 007B | E! 25708, Rm# 244, Fifth sink is |
clogged. 10/03/12 LM
| 10/17/2012 9:55:52 AM | SHP | |||||||
| 32 | 100001356075 | 25708 | 2 | SHP | 10/3/2012 9:57:18 AM | MRS | 070A | E! 25708, Rm# 223, ( Main |
Hallway) Water fountain leaks and clogs. 10/03/12 LM
| 10/17/2012 9:57:18 AM | SHP | |||||||
| 33 | 100001359989 | 25430 | 2 | APPR | 10/4/2012 7:39:19 AM | ECS | 036D | 25430/ Refer to Akima per David |
P. - Belt not on AHU1E ERV wheel ; UMCS WO 80095
| 10/18/2012 7:39:19 AM | APPR | |||||||
| 34 | 100001360086 | 25715 | 2 | APPR | 10/4/2012 8:27:27 AM | MRS | 007B | 25715 Rm 122 female shower |
clogged
| 10/18/2012 8:27:27 AM | APPR | |||||||
| 35 | 100001359994 | 25715 | 2 | APPR | 10/4/2012 8:29:11 AM | MRS | 007D | 25715 Rm 207 Urinal overflows |
when flushed
| 10/18/2012 8:29:11 AM | APPR | |||||||
| 36 | 100001351483 | 00317 | 2 | TSFM | 9/17/2012 2:59:23 PM | MRS | 003B | (R) E! 317 attn David W D23 |
ceiling flaking above kitchen 1459 17 sep 12 kr
| 10/2/2012 11:05:29 AM | TSFM | |||||||
| 37 | 100001351099 | 00317 | 2 | TSFM | 9/17/2012 7:45:33 AM | ECS | 006E | (R)00317, Exhaust fan on roof |
not work need lift to reach exhaust fans. (PM WO#
174932). 9/17/12 LM
| 10/3/2012 12:55:51 PM | TSFM | |||||||
| 38 | 100001352440 | 28411 | 1 | SHP | 10/2/2012 11:33:47 AM | PMS | 021D | E! 28411 attn Oscar fire alarm |
showing trouble 1134 02 oct 12 kr
10/4/2012 11:33:47 AM SHP
Look Ahead Rep Template
| Attachment 5.6 - 6 |
| DPW- Public Works Look Ahead Report 09 Oct - 12 Oct, 2012 |
| PUBLIC WORKS |
| PREVENTATIVE MAINTENANCE DIVISION: |
| Fire Alarm/ Suppression Buildings: |
| List faclities/components to be accomplished |
| All fire alarm/suppression components |
| Equipment PM: |
| List faclities/components to be accomplished |
| HVAC Equipment (i.e., air handlers, pumps, exhaust fans, fire suppression if applicable) |
| List faclities/components to be accomplished |
| COMPONENT INSPECTORS: |
| The Component Inspectors will inspect mechanicalequipment, collect data and complete reports for buildings |
| List faclities/components to be accomplished |
| PROJECT DIVISION: |
| List projects in process and to be scheduled |
Electrical Lines Demarcation
Attachment 5.6 - 7
Gas Lines Demarcation
Attachment 5.6 - 8
Wastewater Lines Demarcation
Attachment 5.6 - 9
Water Lines Demarcation
Attachment 5.6 - 10
Electrical Distro Inventory
| Attachment 5.6 - 11 Electrical Distribution Inventory | ||||
| ELECTRICAL DISTRIBUTION SYSTEM | ||||
| COMPONENT | SIZE | QUANTITY | UNIT | APPROXIMATE YEAR OF CONSTRUCTION |
| Primary Overhead | ||||
| 3 Phase | Large | 3,777 | Linear Feet | 1980 |
| 3 Phase | Small | 9,325 | Linear Feet | 1980 |
| Primary Underground | ||||
| 3 Phase in Ductbank | Large | 1,062 | Linear Feet | 2004 |
| 3 Phase in Ductbank | Small | 5,341 | Linear Feet | 2003 |
| 3 Phase in Ductbank | Small | 1,729 | Linear Feet | 2002 |
Secondary Underground 7,829 Linear Feet 2002
| Switches | |||
| Pole mounted | 4 | Each | 2005 |
| Pad mounted Sectionalizing | 3 | Each | 2004 |
| Risers | 10 | Each | 2002 |
| Manholes | 11 | Each | 2002 |
| Handholes | 1 | Each | 2002 |
| Transformers | ||||
| Pole mounted 1 Phase | 15 kVA | 11 | Each | 1980 |
| 25 kVA | 35 | Each | 1980 | |
| 50 kVA | 13 | Each | 1980 | |
| 75 kVA | 3 | Each | 1980 | |
| 100 kVA | 6 | Each | 1980 | |
| Pole mounted 3 Phase | 30 kVA | 1 | Each | 2002 |
| 150 kVA | 1 | Each | 2002 | |
| 225 kVA | 1 | Each | 2002 | |
| 500 kVA | 3 | Each | 2002 | |
| 1500 kVA | 1 | Each | 2002 |
Nat Gas Distro Inventory
| Attachment 5.6 - 12 | ||||
| NATURAL GAS DISTRIBUTION SYSTEM | ||||
| COMPONENT | SIZE | QUANTITY | UNIT | APPROXIMATE YEAR OF CONSTRUCTION |
| Mains | ||||
| Polyehylene Pipe | 4" | 3,341 | Linear Feet | 1996 |
| 6" | 1,015 | Linear Feet | 1996 | |
| 8" | 8,790 | Linear Feet | 1996 | |
| 10" | 8,082 | Linear Feet | 1996 | |
| 12" | 5,354 | Linear Feet | 1996 | |
| Total Mains | 26,582 | Linear Feet |
| Service Laterals | ||||
| Polyehylene Pipe | <2" | 2,456 | Linear Feet | 1996 |
| 2" | 335 | Linear Feet | 1996 | |
| 2.5" | 1,875 | Linear Feet | 1996 | |
| 3" | 977 | Linear Feet | 1996 | |
| 4" | 89 | Linear Feet | 1996 | |
| 6" | 1,289 | Linear Feet | 1996 | |
| Total Service Laterals | 7,021 | Linear Feet |
| Building Shut-off Valves | 34 | Each | 1996 | |
| Regulators | 1.5" | 46 | Each | 1996 |
| Main Valves | ||||
| 1" | 4 | Each | 1996 | |
| 2" | 5 | Each | 1996 | |
| 3" | 3 | Each | 1996 | |
| 4" | 2 | Each | 1996 | |
| 6" | 2 | Each | 1996 | |
| 8" | 13 | Each | 1996 | |
| 10" | 8 | Each | 1996 | |
| 12" | 2 | Each | 1996 | |
| Total Main Valves | 39 | Each |
Water Inventory
| Attachment 5.6 - 13 | ||||
| POTABLE WATER SYSTEM | ||||
| COMPONENT | SIZE | QUANTITY | UNIT | APPROXIMATE YEAR OF CONSTRUCTION |
| MAIN LINES | ||||
| PVC - SCHEDULE 40 | 2" | 8,996 | Linear Feet | 1997 |
| 3" | 2,083 | Linear Feet | 1997 | |
| 4" | 1,144 | Linear Feet | 1997 | |
| 6" | 37,776 | Linear Feet | 1997 | |
| 8" | 7,211 | Linear Feet | 1997 | |
| 10" | 9,504 | Linear Feet | 1997 | |
| 14" | 127 | Linear Feet | 1997 | |
| TOTAL MAIN LINES | 66,841 | Linear Feet |
| SERVICE LINES | ||||
| PVC - SCHEDULE 40 | 2" | 6,843 | Linear Feet | 1997 |
| 3" | 89 | Linear Feet | 1997 | |
| 4" | 428 | Linear Feet | 1997 | |
| 6" | 495 | Linear Feet | 1997 | |
| TOTAL SERVICE LINES | 7,855 | Linear Feet |
| MAIN VALVES | ||||
| 2" | 31 | Each | 1997 | |
| 3" | 4 | Each | 1997 | |
| 4" | 3 | Each | 1997 | |
| 6" | 75 | Each | 1997 | |
| 8" | 14 | Each | 1997 | |
| 10" | 19 | Each | 1997 | |
| 14" | 1 | Each | 1997 | |
| Post Indicator Valves | 6" | 16 | Each | 1997 |
| Gate Valves | 6" | 6 | Each | 1997 |
| Valve Pits | 3 | Each | 1997 | |
| Meters | 4" | 20 | Each | 1997 |
| Water Storage Tank | Each | 1997 | ||
| No. 929 - Steel / Elevated | 250,000 gal | 1 | Each | 1942 |
| Fire Suppression System | ||||
| PVC - Schedule 80 | 2" | Linear Feet | 2009 | |
| 6" | 106 | Linear Feet | 2009 | |
| 8" | 1,051 | Linear Feet | 2009 | |
| 10" | 4,935 | Linear Feet | 2009 | |
| Total Mains | 3,477 | Linear Feet | ||
| 9,569 | ||||
| Fire Hydrants | 74 | Each | 2009 |
Wastewater Inventory
| Attachment 5.6 - 14 | ||||
| WASTEWATER COLLECTION SYSTEM | ||||
| COMPONENT | SIZE | QUANTITY | UNIT | APPROXIMATE YEAR OF CONSTRUCTION |
| Gravity Lines | ||||
| PVC | 4" | 601 | Linear Feer | 2000 |
| 6" | 2,473 | Linear Feer | 2006 | |
| 8" | 441 | Linear Feer | 2000 | |
| 8" | 17,693 | Linear Feer | 2006 | |
| 10" | 471 | Linear Feer | 2000 | |
| 10" | 7,048 | Linear Feer | 2006 | |
| 12" | 2,032 | Linear Feer | 2006 | |
| Cast Iron | 10" | 2,000 | Linear Feer | 1959 |
| Total Gravity Lines | 32,759 | Linear Feer |
| Service Laterals | ||||
| PVC | 4" | 108 | Linear Feer | 2006 |
| 6" | 17 | Linear Feer | 2000 | |
| 6" | 1,401 | Linear Feer | 2006 | |
| 8" | 106 | Linear Feer | 2000 | |
| 8" | 31 | Linear Feer | 2006 | |
| Total Service Laterals | 1,663 | Linear Feer |
| Manholes | 103 | Each | 2006 | |
| Cleanouts | 10 | Each | 2006 | |
| Flow Meter | 12" | 1 | Each | 2011 |