Technical Exhibit 2h Gillem Enclave Energy Conservation Measures.pdf

PDF 80 KB Posted

Attached to
Fort Gillem Enclave Base Operations and Maintenance Support Services (BASOPS)
Solicitation number
W91249-19-R-0019
Issued by

About this file

This document outlines energy conservation measures to be implemented at Fort Gillem Enclave under a base operations and maintenance support services contract. Key measures include installing ceiling and floor insulation, pipe insulation, and high-efficiency motors. Lighting upgrades such as installing T8 fluorescent lamps and electronic ballasts, compact fluorescent bulbs, and LED exit signs are also specified. Other measures involve replacing water fixtures, installing motion sensors, caulks and weatherstripping, and optimizing HVAC controls. The related federal contract opportunity is for base operations and maintenance support services at Fort Gillem Enclave under solicitation number W91249-19-R-0019 issued by the Department of the Army Materiel Command Mission and Installation Contracting Command at Fort Eustis.

View the file

Other files

File Type Posted
Amendment W9124919R00190006.pdf PDF
A42_Sample Pricing Worksheet_FBR.xlsx XLSX spreadsheet
A1_Performance Work Statement_27Feb2020.docx DOCX document
Conformed Copy of Solicitation W9124919R0019.pdf PDF
Amendment W9124919R00190005.pdf PDF
Conformed Copy of Solicitation W9124919R0019.pdf PDF
Technical Attachment C Grounds Maintenance.docx DOCX document
TE 2H - Gillem Enclave Energy Conservation Measures.pdf PDF
TE 2C - Task Codes.pdf PDF
TE 2D - Gillem Enclave Training and Medical Testing.pdf PDF
A3_SCA WD 2015-4471_Rev14_23Dec19.docx DOCX document
TE 5 - Gillem Enclave GFV and GFE Listing.xlsx XLSX spreadsheet
A1_Performance Work Statement_17Feb2020.docx DOCX document
Amendment W9124919R00190004.pdf PDF
Technical Attachment B Solid Waste Management.docx DOCX document
TE 2G - Gillem Enclave Financial Mgmt A76 Roles and Courses.pdf PDF
TE 1A - Gillem Enclave Real Property inventory.pdf PDF
TE 7 - Gillem Enclave Events.xlsx XLSX spreadsheet
TE 1B - Gillem Enclave Area Map.pdf PDF
Technical Attachment I - FXD Maintenance Services.docx DOCX document
A5_Specific Relevant Contracts Sheet.docx DOCX document
TE 4 - Gillem Enclave Forms.xlsx XLSX spreadsheet
TE 2B - Estimated PWO Workload Data.pdf PDF
A4_Subcontractor Teaming Partner Consent Form.docx DOCX document
TE 6 - Gillem Enclave Grounds Map.xlsx XLSX spreadsheet
Technical Attachment F Facility Maintenance Horizontal.docx DOCX document
TE 2A - Estimated DMO Workload.pdf PDF
TE 2E - Gillem Enclave Service Order Tech A76 Roles and Courses.pdf PDF
TE 3 - Gillem Enclave Est Dump and Contain Sizes and Locations.xlsx XLSX spreadsheet
Technical Attachment D Pavement Clearance.docx DOCX document
Technical Attachment H Pest Management.docx DOCX document
TE 2F - Gillem Enclave Equipment Listing.xlsx XLSX spreadsheet
A43_Questions and Answers_21Feb2020.docx DOCX document
Technical Attachment E Facility Maintenance Vertical.docx DOCX document
Technical Attachment A Facility Maintenance Instruction.docx DOCX document
Amendment_W9124919R00190003.pdf PDF
Amendment_W9124919R00190002.pdf PDF
Amendment_W9124919R00190001.pdf PDF
A42_Sample Pricing Worksheet_FBR.xlsx XLSX spreadsheet
Technical Exhibit 2g Gillem Enclave Financial Mgmt A76 Roles and Courses.pdf PDF
Technical Exhibit 1B Gillem Enclave Area Map.pdf PDF
A18_Technical Exhibit Bldg00760.xlsx XLSX spreadsheet
Solicitation W91249-19-R-0019.pdf PDF
A41_TechnicalExhibits-3 Gov Furnished Veh.xlsx XLSX spreadsheet
A17_Technical Exhibit Bldg00720.xlsx XLSX spreadsheet
A23_Technical Exhibit Bldg00900.xlsx XLSX spreadsheet
Technical Exhibit 3 IMCOM Standards.pdf PDF
A36_Technical Exhibit Deliverables.docx DOCX document
A31_Technical Exhibit Bldg00938.xlsx XLSX spreadsheet
Technical Attachment E Facility Maintenance Vertical.docx DOCX document
Show 40 more

Latest 50 of 98 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GILLEM ENCLAVE -Energy Conservation Measures

FOUO‐Source Selection Sensitive – See FAR 2.101 and FAS 3.104

ENERGY CONSERVATION MEASURES

1. Energy Conservation Measures (ECMs). An energy conservation measure (ECM) is defined as a modification which has been determined to be likely to improve the efficiency of energy use and to reduce energy costs in an amount sufficient to enable payback within the useful life of the modification. The Department of Energy has established a comprehensive list of (ECMs) that should be carried out in Federal buildings. This list is provided in 10 CFR Part 450, Subpart D, 1 Jan 1993, Energy. The Contractor shall perform approved ECMs on a line item basis - indefinite quantity -with respect to the specifications that follow.

C.1.1 Ceiling Insulation. Ceiling insulation shall be that amount which is required to raise the total ceiling insulation to R-Value 30.

C.1.2 Floor Insulation. Floor insulation shall be that amount which is required to raise the total floor insulation to R-Value 19.

C.1.3 Pipe Insulation. Insulation thickness shall be determined from 1989 ASHRAE Fundamentals Handbook, Chapter 22, Table 11. Insulation shall be clean and dry when installed and kept dry during finish application. Materials shall be installed neatly with smooth and even surfaces. Jackets shall be drawn tightly and smoothly fastened down on longitudinal and end laps. No scrap pieces shall be used where a full-length section will fit. All surface finishes shall be extended to protect all surfaces, ends, and raw edges of insulation. Insulation shall continue through pipe hangars and pipe sleeves.

C.1.4 Small and Large Commercial Package Air Conditioning and Heating Equipment. Small and large commercial package air conditioning and heating equipment, packaged terminal air conditioners and heat pumps, warm-air furnaces, packaged boilers, storage water heaters, instantaneous water heaters, and unfired hot water storage tanks shall meet or exceed the 1 January 1994 standards specified in Public Law 102-486, Subtitle C, Section 122, 24 OCT 1992, Energy Policy Act of 1992.

C.1.5 High Efficiency Motors. High efficiency motors shall meet or exceed the energy conservation requirements of Public Law 102-486, Subtitle C, Section 122, 24 OCT 1992, Energy Policy Act of 1992. Motor controls shall increase efficiency of operation not less than five percentage points for two Hp motors or less and not less than three percentage points for

2.1 Hp - 15 Hp motors.

C.1.6 Residential Oil Burners. Residential burners for oil fired heating equipment shall be certified by the manufacturer to be capable of yielding an efficiency rating of 82 percent or higher in a new furnace as measured by a standard steady state efficiency test measuring CO3 and stack temperature.

C.1.7 Fluorescent Lighting. Standard fluorescent lighting shall be replaced with energy efficient T8 lamps, electronic ballasts, fixtures, and lenses. Total system efficacy shall exceed 90 lumens/watt. Fixture and troffer/lens shall be approved by the Government.

C.1.7.1 Electronic Ballasts. Electronic ballasts shall meet the following criteria: UL listed Class P, Sound Rated A, total harmonic distortion less than ten percent, flicker less than ten percent, designed to withstand line transients per IEEE 587 category A, and a three year warranty.

Approved manufacturers are: Advance Transformer Co. MagneTek Triad, ELBA, Electronic

USAG FORT GORDON – GILLEM ENCLAVE

FOUO‐Source Selection Sensitive – See FAR 2.101 and FAS 3.104

Ballast Technology, ETTA Industries Inc., Howard, Motorola Lighting Inc., OSRAM Corporation, Smallwood P C/Sci., Toshiba Electronics, and Valmont Electric. No substitutions shall be made without Government approval.

C.1.7.2 T8 Fluorescent Lamps. Fluorescent lamps must meet applicable sections of ANSI C82 and C78. In general, lamps shall be 265 mA T8 rapid start type as follows: two lamps shall be 17 Watt F17T8, three lamps shall be 25 Watt F25T8, four lamps shall be 32 Watt F32T8, two U-tubes shall be 31 Watt FB31T8. Approved manufacturers are: General Electric, Mitsubishi, OSRAM Corporation, Panasonic, Phillips, SLI and Sylvania. No substitutions shall be made without Government approval.

C.1.8 Compact Fluorescent Lighting. Compact fluorescent bulbs shall replace standard incandescent bulbs. The Color Rendering Index (CRI) shall be 82 or above. Approved manufacturers are: General Electric, Mitsubishi, OSRAM Corporation, Panasonic, Phillips, and Sylvania. No substitutions shall be made without Government approval.

C.1.9 Exit Signs. Light Emitting Diode (LED) exit signs shall replace incandescent and fluorescent exit lights. Rated bulb life shall exceed ten years. The sign shall use eight watts or less per face. Signs shall be UL listed under the 924 Standard and meet or exceed OSHA requirements, the NFPA Life Safety Code, and the National Electric Code. Signs must be approved by the Fire Prevention and Protection Division of the Directorate of Public Works.

C.1.10 Motion Sensors. Motion sensors shall be UL listed 67E4 for ultrasonic models and 27D9 for passive models. The sensors shall have a LED positive detection indicator. A recessed adjustment shall allow for relay setting from 30 seconds to 30 minutes. Each sensor shall have at least a three year warranty against defect. The Contractor shall use Mytech Corporation sensors or Government-approved equivalent.

C.1.11 Water Consuming End Equipment. Shower heads, faucets, water closets and urinals shall meet or exceed the water conservation standards of Public Law 102-486, Subtitle C, Section 123, 24 OCT 1992, Energy Policy Act of 1992. Equipment chosen to fulfill this requirement shall be approved by the Government.

C.1.12 Caulks, Sealants and Weather-stripping. Caulks, sealants and weather-stripping shall be applied to prevent the passage of heat, air and moisture. Materials shall be installed neatly with smooth and even surfaces.

C.1.13 HVAC Controls. HVAC controls shall be: (1) Automatic, turn down, time actuated thermostats; (2) Steam controls, valves, thermostats, timers, or external temperature sensors to limit space temperatures; (3) Economizer controls and systems to utilize outside air in lieu of conditioned air when outside temperature will assist; (4) Controls to reduce air distribution to meet demand; (5) Controls to reduce heating or air conditioning systems output to minimum levels during unoccupied periods; and/or (6) Automatic computer, microprocessor and logic controller associated with direct digital or pneumatic HVAC control.