W91328-19-R-0006-Amendment 0004_UTTR RTA_Package 2 Rail-MTF Submittal Register.xlsx
XLSX spreadsheet 126 KB Posted
- Attached to
- UTTR Missile Motor Receipt & Storage Facility
- Solicitation number
- W9123819R0006
About this file
This is a pre-solicitation notice for design-build construction services for missile motor receipt and storage facilities at the Utah Test and Training Range. The scope of work includes construction of eighteen earth-covered modular storage magazines, a 7,000 square foot motor transfer facility, approximately fifteen miles of railroad track, and supporting site work. The estimated cost range is $25-100 million. The period of performance for construction is 730 days. The solicitation is unrestricted and will be issued on or around September 23, 2019 via the FedBizOpps website. Questions should be directed to the identified contracting specialist by email. Interested parties must register in the System for Award Management and FedBizOpps to access solicitation documents on the latter platform.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
W91328-17-D-0027_UTTR RTA_Packa
| TITLE: | Rail & Motor Transfer Facility | SUBMITTAL REGISTER | ||||||||||||||||
| JOB NAME: | D5 Missile Motor Receipt/Storage Facilities, UTTR | |||||||||||||||||
| LOCATION: | Utah Test and Training Range | |||||||||||||||||
| CONTRACT NO: | W91238-17-D-0027 | |||||||||||||||||
| CONTRACTOR: | ||||||||||||||||||
| CONTRACTOR SCHEDULE DATES | CONTRACTOR ACTION | APPROVING AUTHORITY | ||||||||||||||||
| (a) | (b) | (c) | (d) | (e) | (f) | (g) | (h) | (i) | (j) | (k) | (l) | (m) | (n) | (o) | (p) | (q) | (r) |
| Line | Activity # | Transmittal # | Specification Section | SD # | Submittal Description | Item Submitted | Paragraph # | Classification: GOVT or A/E Reviewer | Submit | Approval Needed By | Material Needed By | Action Code | Date Of Action | Date FWD to APPR / Auth Date RCD From CONTR | Date FWD To Other Revwr | Date RCD From Other Reviewer | Action Code | Date Of Action | Mailed To CONTR/ Date RCD From APPR Authority | Remarks |
| 1 | 01 45 35 | 1 | Preconstruction Submittals | SIOR Letter of Acceptance | 3.1.1 | G | ||||||||||||||
| 2 | 01 45 35 | 1 | Preconstruction Submittals | Project Manual | 3.1.1 | G | ||||||||||||||
| 3 | 01 45 35 | 1 | Preconstruction Submittals | Project Manual | 3.1.1 | G | ||||||||||||||
| 4 | 01 45 35 | 1 | Preconstruction Submittals | Written Practices | 3.1.1 | |||||||||||||||
| 5 | 01 45 35 | 1 | Preconstruction Submittals | NDT Procedures and Equipment Calibration Records | 3.1.1 | |||||||||||||||
| 6 | 01 45 35 | 6 | Test Reports | Daily Reports | 3.1.1 | |||||||||||||||
| 7 | 01 45 35 | 6 | Test Reports | Daily Reports | 3.1.3 | |||||||||||||||
| 8 | 01 45 35 | 6 | Test Reports | Daily Reports | 3.1.3 | |||||||||||||||
| 9 | 01 45 35 | 6 | Test Reports | Biweekly Reports | 3.1.1 | |||||||||||||||
| 10 | 01 45 35 | 7 | Certificates | Fabrication Plant | 2.1 | |||||||||||||||
| 11 | 01 45 35 | 7 | Certificates | Certificate of Compliance | 2.1 | |||||||||||||||
| 12 | 01 45 35 | 7 | Certificates | Special Inspector of Record | 1.5.6 | G | ||||||||||||||
| 13 | 01 45 35 | 7 | Certificates | Special Inspector | 1.5 | G | ||||||||||||||
| 14 | 01 45 35 | 7 | Certificates | Qualification Records | 3.1.1 | |||||||||||||||
| 15 | 01 45 35 | 11 | Closeout Submittals | Interim Final Report | 3.1.1 | |||||||||||||||
| 16 | 01 45 35 | 11 | Closeout Submittals | Comprehensive Final Report | 3.1.1 | G | ||||||||||||||
| 17 | 01 45 35 | 11 | Closeout Submittals | Comprehensive Final Report | 3.1.3 | G | ||||||||||||||
| 18 | 01 91 00.15 | 1 | Preconstruction Submittals | Commissioning Firm | 1.7 | G DO | ||||||||||||||
| 19 | 01 91 00.15 | 1 | Preconstruction Submittals | Lead Commissioning Specialist | 1.7.1 | G DO | ||||||||||||||
| 20 | 01 91 00.15 | 1 | Preconstruction Submittals | Technical Commissioning Specialists | 1.7.2 | G DO | ||||||||||||||
| 21 | 01 91 00.15 | 1 | Preconstruction Submittals | Commissioning Firm's Contract | 1.7 | G DO | ||||||||||||||
| 22 | 01 91 00.15 | 6 | Test Reports | Interim Construction Phase Commissioning Plan | 3.1.2.1 | G DO | ||||||||||||||
| 23 | 01 91 00.15 | 6 | Test Reports | Final Construction Phase Commissioning Plan | 3.1.2.2 | G DO | ||||||||||||||
| 24 | 01 91 00.15 | 6 | Test Reports | Pre-Functional Checklists | 3.1.4.2 | G DO | ||||||||||||||
| 25 | 01 91 00.15 | 6 | Test Reports | Issues Log | 1.9 | |||||||||||||||
| 26 | 01 91 00.15 | 6 | Test Reports | Commissioning Report | 3.2 | G DO | ||||||||||||||
| 27 | 01 91 00.15 | 6 | Test Reports | Post-Construction Trend Log Report | 3.3.1 | G DO | ||||||||||||||
| 28 | 01 91 00.15 | 7 | Certificates | Certificate of Readiness | 1.1 | G DO | ||||||||||||||
| 29 | 01 91 00.15 | 10 | Operation and Maintenance Data | Training Plan | 3.1.5 | G RO | ||||||||||||||
| 30 | 01 91 00.15 | 10 | Operation and Maintenance Data | Training Attendance Rosters | 3.1.5 | G RO | ||||||||||||||
| 31 | 01 91 00.15 | 10 | Operation and Maintenance Data | Systems Manual/Computerized Maintenance Management System Manual | 3.1.6 | G DO | ||||||||||||||
| 32 | 01 91 00.15 | 10 | Operation and Maintenance Data | Maintenance and Service Life Plans | 3.1.7 | G DO | ||||||||||||||
| 33 | 01 91 00.15 | 11 | Closeout Submittals | Final Commissioning Report | 3.2 | S DO | ||||||||||||||
| 34 | 03 11 13 | 2 | Shop Drawings | Formwork | 2.2.1 | G | ||||||||||||||
| 35 | 03 11 13 | 2 | Shop Drawings | Formwork | 3.1.1 | G | ||||||||||||||
| 36 | 03 11 13 | 2 | Shop Drawings | Form Removal Schedule | 2.2.1 | G | ||||||||||||||
| 37 | 03 11 13 | 3 | Product Data | Form Materials | 2.2 | |||||||||||||||
| 38 | 03 11 13 | 4 | Samples | Sample Panels | 1.3 | G | ||||||||||||||
| 39 | 03 11 13 | 5 | Design Data | Calculations | 2.1 | |||||||||||||||
| 40 | 03 11 13 | 6 | Test Reports | Inspection | 3.2 | |||||||||||||||
| 41 | 03 15 00 | 2 | Shop Drawings | Waterstops | 2.3 | G | ||||||||||||||
| 42 | 03 15 00 | 3 | Product Data | Preformed Expansion Joint Filler | 2.1 | |||||||||||||||
| 43 | 03 15 00 | 3 | Product Data | Sealant | 2.2 | |||||||||||||||
| 44 | 03 15 00 | 3 | Product Data | Waterstops | 2.3 | |||||||||||||||
| 45 | 03 15 00 | 4 | Samples | Field-Molded Type | 2.2.1 | |||||||||||||||
| 46 | 03 15 00 | 4 | Samples | Waterstops | 2.3 | |||||||||||||||
| 47 | 03 15 00 | 4 | Samples | Spliced Segments of Waterstops | 2.3 | G | ||||||||||||||
| 48 | 03 15 00 | 7 | Certificates | Preformed Expansion Joint Filler | 2.1 | |||||||||||||||
| 49 | 03 15 00 | 7 | Certificates | Sealant | 2.2 | |||||||||||||||
| 50 | 03 15 00 | 7 | Certificates | Waterstops | 2.3 | |||||||||||||||
| 51 | 03 20 00 | 2 | Shop Drawings | Reinforcement | 3.1 | G | ||||||||||||||
| 52 | 03 20 00 | 3 | Product Data | Reinforcing Steel | 2.1 | G | ||||||||||||||
| 53 | 03 20 00 | 6 | Test Reports | Tests, Inspections, and Verifications | 2.5 | G | ||||||||||||||
| 54 | 03 20 00 | 7 | Certificates | Reinforcing Steel | 2.1 | |||||||||||||||
| 55 | 03 30 00 | 1 | Preconstruction Submittals | Quality Control Plan | 1.5.2 | G | ||||||||||||||
| 56 | 03 30 00 | 1 | Preconstruction Submittals | Laboratory Accreditation | 1.5.1 | |||||||||||||||
| 57 | 03 30 00 | 1 | Preconstruction Submittals | Sampling Plan | 3.9.5.6 | G | ||||||||||||||
| 58 | 03 30 00 | 3 | Product Data | Recycled Content Products | Part 2 | |||||||||||||||
| 59 | 03 30 00 | 3 | Product Data | Cementitious Materials | 2.2 | |||||||||||||||
| 60 | 03 30 00 | 3 | Product Data | Vapor Retarder | 2.11 | |||||||||||||||
| 61 | 03 30 00 | 3 | Product Data | Floor Finish | 2.1.5 | |||||||||||||||
| 62 | 03 30 00 | 3 | Product Data | Floor Hardener | 2.9 | |||||||||||||||
| 63 | 03 30 00 | 3 | Product Data | Chemical Admixtures | 2.4 | |||||||||||||||
| 64 | 03 30 00 | 4 | Samples | Surface Retarder | 2.4.4 | |||||||||||||||
| 65 | 03 30 00 | 5 | Design Data | Mixture Proportions | 2.1.1 | G | ||||||||||||||
| 66 | 03 30 00 | 6 | Test Reports | Mixture Proportions | 2.1.1 | G | ||||||||||||||
| 67 | 03 30 00 | 6 | Test Reports | Testing and Inspection for CQC | 3.9 | G | ||||||||||||||
| 68 | 03 30 00 | 6 | Test Reports | Fly Ash | 2.2.2 | |||||||||||||||
| 69 | 03 30 00 | 6 | Test Reports | Ground Granulated Blast-Furnace (GGBF) Slag | 2.2.5 | |||||||||||||||
| 70 | 03 30 00 | 6 | Test Reports | Aggregates | 2.3 | |||||||||||||||
| 71 | 03 30 00 | 6 | Test Reports | Air Content | 3.9.5.1 | |||||||||||||||
| 72 | 03 30 00 | 6 | Test Reports | Slump | 3.9.5.3 | |||||||||||||||
| 73 | 03 30 00 | 6 | Test Reports | Compressive Strength | 3.9.5.6 | |||||||||||||||
| 74 | 03 30 00 | 6 | Test Reports | Water | 2.5 | |||||||||||||||
| 75 | 03 30 00 | 7 | Certificates | Contractor Quality Control personnel | 1.5 | |||||||||||||||
| 76 | 03 30 00 | 7 | Certificates | Ready-Mix Plant | 3.2.1 | |||||||||||||||
| 77 | 03 35 00 | 3 | Product Data | Recycled Content Products | Part 2 | |||||||||||||||
| 78 | 03 35 00 | 4 | Samples | Field Test Panels | 1.3.1 | |||||||||||||||
| 79 | 03 35 00 | 4 | Samples | Sample Wall Panels | 1.3.1.1 | |||||||||||||||
| 80 | 03 35 00 | 4 | Samples | Slab Panels | 1.3.1.2 | |||||||||||||||
| 81 | 03 39 00 | 3 | Product Data | Curing Materials | 2.1 | |||||||||||||||
| 82 | 03 39 00 | 6 | Test Reports | Testing and Inspection for CQC | 3.2 | |||||||||||||||
| 83 | 03 39 00 | 8 | Manufacturer’s Instructions | Curing Compound | 2.1 | |||||||||||||||
| 84 | 05 05 23.13 | 1 | Preconstruction Submittals | Personnel Qualification | 1.4.1 | G | ||||||||||||||
| 85 | 05 05 23.13 | 1 | Preconstruction Submittals | Procedure Description | 2.1.1 | G | ||||||||||||||
| 86 | 05 05 23.13 | 3 | Product Data | Ultrasonic Inspection | 1.4.1 | |||||||||||||||
| 87 | 05 05 23.13 | 6 | Test Reports | Equipment Qualifications | 1.4.5 | |||||||||||||||
| 88 | 05 05 23.13 | 6 | Test Reports | Inspection Test Reports | 3.4.1 | |||||||||||||||
| 89 | 05 05 23.16 | 1 | Preconstruction Submittals | Welding Quality Assurance Plan | 3.2 | |||||||||||||||
| 90 | 05 05 23.16 | 3 | Product Data | Welding Procedure Qualifications | 1.3 | G | ||||||||||||||
| 91 | 05 05 23.16 | 3 | Product Data | Welder, Welding Operator, and Tacker Qualification | 1.3.5 | |||||||||||||||
| 92 | 05 05 23.16 | 3 | Product Data | Inspector Qualification | 1.3.6 | |||||||||||||||
| 93 | 05 05 23.16 | 3 | Product Data | Previous Qualifications | 1.3.2 | |||||||||||||||
| 94 | 05 05 23.16 | 3 | Product Data | Pre-Qualified Procedures | 1.3.3 | |||||||||||||||
| 95 | 05 05 23.16 | 3 | Product Data | Welding Electrodes and Rods | 2.2 | |||||||||||||||
| 96 | 05 05 23.16 | 6 | Test Reports | Nondestructive Testing | 3.3 | |||||||||||||||
| 97 | 05 05 23.16 | 7 | Certificates | Certified Welding Procedure Specifications (WPS) | 1.3.1 | |||||||||||||||
| 98 | 05 05 23.16 | 7 | Certificates | Certified Brazing Procedure Specifications (BPS) | 1.3.1 | |||||||||||||||
| 99 | 05 05 23.16 | 7 | Certificates | Certified Procedure Qualification Records (PQR) | 1.3.1 | |||||||||||||||
| 100 | 05 05 23.16 | 7 | Certificates | Certified Welder Performance Qualifications (WPQ) | 1.3.1 | |||||||||||||||
| 101 | 05 05 23.16 | 7 | Certificates | Certified Brazer Performance Qualifications (BPQ) | 1.3.1 | |||||||||||||||
| 102 | 05 12 00 | 1 | Preconstruction Submittals | Erection Drawings | 1.3.1.1 | G | ||||||||||||||
| 103 | 05 12 00 | 2 | Shop Drawings | Fabrication Drawings | 1.3.2 | G | ||||||||||||||
| 104 | 05 12 00 | 3 | Product Data | Shop Primer | 2.6.2 | |||||||||||||||
| 105 | 05 12 00 | 3 | Product Data | Welding Electrodes and Rods | 2.4.1 | |||||||||||||||
| 106 | 05 12 00 | 3 | Product Data | Direct Tension Indicator Washers | 2.3.2.3 | |||||||||||||||
| 107 | 05 12 00 | 3 | Product Data | Non-Shrink Grout | 2.4.2 | |||||||||||||||
| 108 | 05 12 00 | 6 | Test Reports | Class B Coating | 2.6.2 | |||||||||||||||
| 109 | 05 12 00 | 6 | Test Reports | Bolts, Nuts, and Washers | 2.3 | |||||||||||||||
| 110 | 05 12 00 | 6 | Test Reports | Weld Inspection Reports | 3.7.1.2 | |||||||||||||||
| 111 | 05 12 00 | 6 | Test Reports | Direct Tension Indicator Washer Inspection Reports | 3.7.2.1 | |||||||||||||||
| 112 | 05 12 00 | 6 | Test Reports | Bolt Testing Reports | 3.7.3.1 | |||||||||||||||
| 113 | 05 12 00 | 6 | Test Reports | Embrittlement Test Reports | 3.7.4 | |||||||||||||||
| 114 | 05 12 00 | 7 | Certificates | Steel | 2.2 | |||||||||||||||
| 115 | 05 12 00 | 7 | Certificates | Bolts, Nuts, and Washers | 2.3 | |||||||||||||||
| 116 | 05 12 00 | 7 | Certificates | Galvanizing | 2.5 | |||||||||||||||
| 117 | 05 12 00 | 7 | Certificates | Welding Procedures and Qualifications | 1.3.3.1 | |||||||||||||||
| 118 | 05 50 13 | 2 | Shop Drawings | Structural Steel Door Frames | 2.12 | G | ||||||||||||||
| 119 | 05 50 13 | 2 | Shop Drawings | Expansion Joint Covers | 2.6 | G | ||||||||||||||
| 120 | 05 50 13 | 2 | Shop Drawings | Bollards/Pipe Guards | 2.8 | G | ||||||||||||||
| 121 | 05 50 13 | 2 | Shop Drawings | Angles and Plates | 2.1 | G | ||||||||||||||
| 122 | 05 50 13 | 3 | Product Data | Corner Guards | 2.4 | |||||||||||||||
| 123 | 05 50 13 | 3 | Product Data | Cover Plates and Frames | 2.5 | G | ||||||||||||||
| 124 | 05 50 13 | 3 | Product Data | Expansion Joint Covers | 2.6 | G | ||||||||||||||
| 125 | 05 50 13 | 3 | Product Data | Floor Gratings | 2.7 | G | ||||||||||||||
| 126 | 05 50 13 | 3 | Product Data | Structural Steel Door Frames | 2.12 | G | ||||||||||||||
| 127 | 05 50 13 | 3 | Product Data | Downspout Terminations | 2.9 | G | ||||||||||||||
| 128 | 05 50 13 | 4 | Samples | Expansion Joint Covers | 2.6 | |||||||||||||||
| 129 | 05 50 13 | 4 | Samples | Control-Joint Covers | ||||||||||||||||
| 130 | 05 50 13 | 4 | Samples | Certificates of Compliance | 2.1 | G | ||||||||||||||
| 131 | 05 50 13 | 4 | Samples | Recycled Content | 2.1 | S | ||||||||||||||
| 132 | 05 52 00 | 2 | Shop Drawings | Fabrication Drawings | 1.2.1 | G | ||||||||||||||
| 133 | 05 52 00 | 2 | Shop Drawings | Iron and Steel Hardware | 3.2 | G | ||||||||||||||
| 134 | 05 52 00 | 2 | Shop Drawings | Steel Shapes, Plates, Bars and Strips | 3.2 | G | ||||||||||||||
| 135 | 05 52 00 | 3 | Product Data | Structural-Steel Plates, Shapes, and Bars | 2.2.1 | G | ||||||||||||||
| 136 | 05 52 00 | 3 | Product Data | Concrete Inserts | 2.2.3 | G | ||||||||||||||
| 137 | 05 52 00 | 3 | Product Data | Protective Coating | 2.1.2 | G | ||||||||||||||
| 138 | 05 52 00 | 3 | Product Data | Steel Railings and Handrails | 2.2.5 | G | ||||||||||||||
| 139 | 05 52 00 | 3 | Product Data | Anchorage and Fastening Systems | 1.2.1 | G | ||||||||||||||
| 140 | 05 52 00 | 7 | Certificates | Welding Procedures | 1.4.1 | G | ||||||||||||||
| 141 | 05 52 00 | 7 | Certificates | Welder Qualification | 1.4.2 | G | ||||||||||||||
| 142 | 05 52 00 | 8 | Manufacturer’s Instructions | Installation Instructions | 3.2 | |||||||||||||||
| 143 | 07 11 13 | 7 | Certificates | Materials | 1.3 | |||||||||||||||
| 144 | 07 19 00 | 3 | Product Data | Water Repellents | 2.2 | |||||||||||||||
| 145 | 07 19 00 | 6 | Test Reports | Water Absorption | 1.3.2 | |||||||||||||||
| 146 | 07 19 00 | 6 | Test Reports | Water Absorption | 2.3.1 | |||||||||||||||
| 147 | 07 19 00 | 6 | Test Reports | Accelerated Weathering | 2.3.1 | |||||||||||||||
| 148 | 07 19 00 | 6 | Test Reports | Resistance to Chloride Ion Penetration | 2.3.1 | |||||||||||||||
| 149 | 07 19 00 | 6 | Test Reports | Moisture Vapor Transmission | 1.3.2 | |||||||||||||||
| 150 | 07 19 00 | 6 | Test Reports | Moisture Vapor Transmission | 2.3.1 | |||||||||||||||
| 151 | 07 19 00 | 6 | Test Reports | Scaling Resistance | 2.3.1 | |||||||||||||||
| 152 | 07 19 00 | 6 | Test Reports | Water Penetration and Leakage | 2.3.1 | |||||||||||||||
| 153 | 07 19 00 | 7 | Certificates | Manufacturer's Qualifications | 1.3.1 | |||||||||||||||
| 154 | 07 19 00 | 7 | Certificates | Applicator's Qualifications | 1.3.1 | |||||||||||||||
| 155 | 07 19 00 | 7 | Certificates | Evidence of Acceptable Variation | 1.3.3 | |||||||||||||||
| 156 | 07 19 00 | 7 | Certificates | Warranty | 1.12 | |||||||||||||||
| 157 | 07 19 00 | 8 | Manufacturer’s Instructions | Application | 3.4 | |||||||||||||||
| 158 | 07 19 00 | 8 | Manufacturer’s Instructions | Safety Data Sheets | 1.7.1 | |||||||||||||||
| 159 | 07 21 13 | 3 | Product Data | Manufacturer's Standard Details | 1.3 | G | ||||||||||||||
| 160 | 07 21 13 | 3 | Product Data | Block or Board Insulation | 2.1 | G | ||||||||||||||
| 161 | 07 21 13 | 3 | Product Data | Vapor Retarder | 2.2 | G | ||||||||||||||
| 162 | 07 21 13 | 3 | Product Data | Pressure Sensitive Tape | 2.3 | G | ||||||||||||||
| 163 | 07 21 13 | 3 | Product Data | Protection Board or Coatings | 1.4 | G | ||||||||||||||
| 164 | 07 21 13 | 3 | Product Data | Accessories | 2.5 | G | ||||||||||||||
| 165 | 07 21 13 | 7 | Certificates | Block or Board Insulation | 2.1 | G | ||||||||||||||
| 166 | 07 21 13 | 7 | Certificates | Vapor Retarder | 2.2 | G | ||||||||||||||
| 167 | 07 21 13 | 7 | Certificates | Protection Board or Coating | 2.4 | G | ||||||||||||||
| 168 | 07 21 13 | 7 | Certificates | Special Warranties | 1.7 | G | ||||||||||||||
| 169 | 07 21 13 | 7 | Certificates | Special Warranties | 1.7 | G | ||||||||||||||
| 170 | 07 21 13 | 8 | Manufacturer’s Instructions | Block or Board Insulation | 2.1 | |||||||||||||||
| 171 | 07 21 13 | 8 | Manufacturer’s Instructions | Adhesive | 2.5.1 | |||||||||||||||
| 172 | 07 27 10 | 4 | Samples | Mock-Up | 3.1.2 | G | ||||||||||||||
| 173 | 07 27 10 | 6 | Test Reports | Testing and Inspection | 3.1.3 | G RO | ||||||||||||||
| 174 | 07 27 36 | 1 | Preconstruction Submittals | Qualification of Manufacturer | 1.8.1 | G | ||||||||||||||
| 175 | 07 27 36 | 1 | Preconstruction Submittals | Qualification of Installer | 1.8.2 | G | ||||||||||||||
| 176 | 07 27 36 | 1 | Preconstruction Submittals | Quality Control Plan | 1.9 | G | ||||||||||||||
| 177 | 07 27 36 | 1 | Preconstruction Submittals | Safety Plan | 1.9 | G | ||||||||||||||
| 178 | 07 27 36 | 1 | Preconstruction Submittals | Fire Prevention Plan | 1.7.1 | G | ||||||||||||||
| 179 | 07 27 36 | 1 | Preconstruction Submittals | Respirator Plan | 1.7.2 | G | ||||||||||||||
| 180 | 07 27 36 | 2 | Shop Drawings | Spray Foam Air Barrier | 1.4 | S | ||||||||||||||
| 181 | 07 27 36 | 2 | Shop Drawings | Foam Air Barrier System | 1.9 | G | ||||||||||||||
| 182 | 07 27 36 | 3 | Product Data | Closed Cell | 2.2.2 | G S | ||||||||||||||
| 183 | 07 27 36 | 3 | Product Data | Transition Membrane | 2.3 | G S | ||||||||||||||
| 184 | 07 27 36 | 3 | Product Data | Primers, Adhesives, and Mastics | 2.4 | G S | ||||||||||||||
| 185 | 07 27 36 | 3 | Product Data | Sealants | 2.6 | G S | ||||||||||||||
| 186 | 07 27 36 | 3 | Product Data | Safety Data Sheets | 1.4.2 | G S | ||||||||||||||
| 187 | 07 27 36 | 3 | Product Data | Thermal Barrier Materials | 2.2.1 | G S | ||||||||||||||
| 188 | 07 27 36 | 3 | Product Data | Ignition Barrier Coatings | 2.2.1 | G | ||||||||||||||
| 189 | 07 27 36 | 4 | Samples | Spray Foam Air Barrier | 1.4 | G | ||||||||||||||
| 190 | 07 27 36 | 6 | Test Reports | Field Peel Adhesion Test | 1.4.4 | G | ||||||||||||||
| 191 | 07 27 36 | 6 | Test Reports | Thermographic Test | 3.4.5.1 | G | ||||||||||||||
| 192 | 07 27 36 | 6 | Test Reports | Primers | 1.4.3 | G | ||||||||||||||
| 193 | 07 27 36 | 6 | Test Reports | Flame Spread And Smoke Developed Index Ratings Of SPF Products | 1.4.4 | G | ||||||||||||||
| 194 | 07 27 36 | 6 | Test Reports | Flame Propagation Of Wall Assemblies | 1.4.4 | G | ||||||||||||||
| 195 | 07 27 36 | 6 | Test Reports | Site Inspections | 3.4.1 | G | ||||||||||||||
| 196 | 07 27 36 | 7 | Certificates | Closed cell | 2.2.2 | G | ||||||||||||||
| 197 | 07 27 36 | 7 | Certificates | Qualification of Manufacturer | 1.8.1 | G | ||||||||||||||
| 198 | 07 27 36 | 7 | Certificates | Qualification of Installer | 1.8.2 | G | ||||||||||||||
| 199 | 07 27 36 | 8 | Manufacturer’s Instructions | SPF Handling, Storage, and Spray Procedures | 1.5.1 | G S | ||||||||||||||
| 200 | 07 27 36 | 8 | Manufacturer’s Instructions | Substrate Preparation | 3.2.1 | G | ||||||||||||||
| 201 | 07 27 36 | 9 | Manufacturer’s Field Reports | Core Samples | 1.9 | |||||||||||||||
| 202 | 07 27 36 | 9 | Manufacturer’s Field Reports | Daily Work Record | 3.3.3 | |||||||||||||||
| 203 | 07 27 36 | 9 | Manufacturer’s Field Reports | Visual Inspection and Thermal Scanning | 3.4.5 | |||||||||||||||
| 204 | 07 27 36 | 11 | Closeout Submittals | Volatile Organic Compound (VOC) Content | 2.1.1 | |||||||||||||||
| 205 | 07 27 36 | 11 | Closeout Submittals | Recycled Content | 2.1.2 | |||||||||||||||
| 206 | 07 41 63 | 1 | Preconstruction Submittals | Qualification of Manufacturer | 1.4.1 | G | ||||||||||||||
| 207 | 07 41 63 | 1 | Preconstruction Submittals | Qualification of Installer | 1.4.1 | G | ||||||||||||||
| 208 | 07 41 63 | 1 | Preconstruction Submittals | Qualifications for Welding | 1.4.1 | G | ||||||||||||||
| 209 | 07 41 63 | 1 | Preconstruction Submittals | Work Plan | 1.4.1 | G | ||||||||||||||
| 210 | 07 41 63 | 1 | Preconstruction Submittals | On-Site Inspection and Acceptance Procedure | 1.4.1 | G | ||||||||||||||
| 211 | 07 41 63 | 2 | Shop Drawings | Roofing Panels | 1.4.1 | |||||||||||||||
| 212 | 07 41 63 | 2 | Shop Drawings | Flashing and Accessories | 1.4.1 | G | ||||||||||||||
| 213 | 07 41 63 | 3 | Product Data | Sustainable Acquisition | 1.4.1 | G | ||||||||||||||
| 214 | 07 41 63 | 3 | Product Data | Coil Stock | 1.4.1 | G | ||||||||||||||
| 215 | 07 41 63 | 3 | Product Data | Factory Color Finish | 1.4.1 | G | ||||||||||||||
| 216 | 07 41 63 | 3 | Product Data | Sub-girts and Formed Shapes | 1.4.1 | G | ||||||||||||||
| 217 | 07 41 63 | 3 | Product Data | Closure Materials | 1.4.1 | G | ||||||||||||||
| 218 | 07 41 63 | 3 | Product Data | Insulation | 1.4.1 | G | ||||||||||||||
| 219 | 07 41 63 | 3 | Product Data | Pressure-Sensitive Tape | 1.4.1 | G | ||||||||||||||
| 220 | 07 41 63 | 3 | Product Data | Sealants and Caulking | 1.4.1 | G | ||||||||||||||
| 221 | 07 41 63 | 3 | Product Data | Rated Wall Assembly | 1.4.1 | G | ||||||||||||||
| 222 | 07 41 63 | 3 | Product Data | Galvanizing Repair Paint | 1.4.1 | G | ||||||||||||||
| 223 | 07 41 63 | 3 | Product Data | Enamel Repair Paint | 1.4.1 | G | ||||||||||||||
| 224 | 07 41 63 | 3 | Product Data | Aluminized Steel Repair Paint | 1.4.1 | G | ||||||||||||||
| 225 | 07 41 63 | 3 | Product Data | Accessories | 1.4.1 | G | ||||||||||||||
| 226 | 07 41 63 | 4 | Samples | Coil Stock | 1.4.1 | |||||||||||||||
| 227 | 07 41 63 | 4 | Samples | Roofing Panels | 1.4.1 | |||||||||||||||
| 228 | 07 41 63 | 4 | Samples | Fasteners | 2.3.1.2 | |||||||||||||||
| 229 | 07 41 63 | 4 | Samples | Metal Closure Strips | 2.5.1 | |||||||||||||||
| 230 | 07 41 63 | 4 | Samples | Insulation | 1.4.1 | |||||||||||||||
| 231 | 07 41 63 | 4 | Samples | Manufacturer's Color Charts and Chips | 1.4.1 | |||||||||||||||
| 232 | 07 41 63 | 5 | Design Data | Wind Design Analysis | 1.4.1 | |||||||||||||||
| 233 | 07 41 63 | 5 | Design Data | Seismic Design Analysis | 1.4.1 | G | ||||||||||||||
| 234 | 07 41 63 | 6 | Test Reports | Leakage Tests | 3.4.1.2 | G | ||||||||||||||
| 235 | 07 41 63 | 6 | Test Reports | Fire Rating Test Report | 1.4.1 | G | ||||||||||||||
| 236 | 07 41 63 | 6 | Test Reports | Coatings and Base Metals of Metal Roofing | 3.1 | G | ||||||||||||||
| 237 | 07 41 63 | 6 | Test Reports | Factory Finish and Color Performance Requirements | 1.4.1 | G | ||||||||||||||
| 238 | 07 41 63 | 6 | Test Reports | Wind Uplift Test Report | 1.4.1 | G | ||||||||||||||
| 239 | 07 41 63 | 6 | Test Reports | Seismic Test Report | 1.4.1 | G | ||||||||||||||
| 240 | 07 41 63 | 7 | Certificates | Coil Stock | 1.4.1 | |||||||||||||||
| 241 | 07 41 63 | 7 | Certificates | Fasteners | 2.3.1.2 | |||||||||||||||
| 242 | 07 41 63 | 7 | Certificates | Galvanizing Repair Paint | 1.4.1 | |||||||||||||||
| 243 | 07 41 63 | 7 | Certificates | Enamel Repair Paint | 1.4.1 | |||||||||||||||
| 244 | 07 41 63 | 7 | Certificates | Safety Data Sheets | 1.4.1 | |||||||||||||||
| 245 | 07 41 63 | 7 | Certificates | Coating Physical Properties: | 2.4.4 | |||||||||||||||
| 246 | 07 41 63 | 8 | Manufacturer’s Instructions | Installation of Roof Panel Assemblies | 1.4.1 | |||||||||||||||
| 247 | 07 41 63 | 11 | Closeout Submittals | Warranty | 1.7 | |||||||||||||||
| 248 | 07 41 63 | 11 | Closeout Submittals | Information Form and Placard | 3.3.5 | G | ||||||||||||||
| 249 | 07 41 63 | 11 | Closeout Submittals | Manufacturer's Field Inspection Reports | 3.4.2 | |||||||||||||||
| 250 | 07 41 63 | 11 | Closeout Submittals | Application Instructions | 1.4.1 | |||||||||||||||
| 251 | 07 41 63 | 11 | Closeout Submittals | 20-year 'No-Dollar-Limit' Warranty for Labor and Materials | 1.7.1 | G | ||||||||||||||
| 252 | 07 42 63 | 1 | Preconstruction Submittals | Qualification of Manufacturer | 1.5.3 | |||||||||||||||
| 253 | 07 42 63 | 1 | Preconstruction Submittals | Qualification of Installer | 1.5.4 | |||||||||||||||
| 254 | 07 42 63 | 1 | Preconstruction Submittals | Qualifications for Welding Work | 1.5.4.1 | |||||||||||||||
| 255 | 07 42 63 | 2 | Shop Drawings | Fabrication And Installation Drawings | 1.5.1 | G | ||||||||||||||
| 256 | 07 42 63 | 2 | Shop Drawings | Wall Panel Assemblies | 1.5.1 | G | ||||||||||||||
| 257 | 07 42 63 | 2 | Shop Drawings | Flashing And Accessories | 1.5.1 | G | ||||||||||||||
| 258 | 07 42 63 | 2 | Shop Drawings | Anchorage Systems | 1.5.1 | G | ||||||||||||||
| 259 | 07 42 63 | 3 | Product Data | Certification | G | |||||||||||||||
| 260 | 07 42 63 | 3 | Product Data | sustainable acquisition | 1.5.1 | |||||||||||||||
| 261 | 07 42 63 | 3 | Product Data | Manufacturer's catalog data | 1.5.1 | |||||||||||||||
| 262 | 07 42 63 | 3 | Product Data | Factory Color Finish | 1.5.1 | G | ||||||||||||||
| 263 | 07 42 63 | 3 | Product Data | Sub-Girts And Formed Shapes | 1.5.1 | G | ||||||||||||||
| 264 | 07 42 63 | 3 | Product Data | Closure Materials | 1.5.1 | G | ||||||||||||||
| 265 | 07 42 63 | 3 | Product Data | Insulation | 1.5.1 | G | ||||||||||||||
| 266 | 07 42 63 | 3 | Product Data | Pressure Sensitive Tape | 1.5.1 | G | ||||||||||||||
| 267 | 07 42 63 | 3 | Product Data | Sealants And Caulking | 2.4.4.1 | G | ||||||||||||||
| 268 | 07 42 63 | 3 | Product Data | Enamel Repair Paint | 1.5.1 | G | ||||||||||||||
| 269 | 07 42 63 | 3 | Product Data | Accessories | 1.5.1 | G | ||||||||||||||
| 270 | 07 42 63 | 4 | Samples | Wall Panel Assemblies | 1.5.1 | G | ||||||||||||||
| 271 | 07 42 63 | 4 | Samples | Fasteners | 1.5.1 | G | ||||||||||||||
| 272 | 07 42 63 | 4 | Samples | Metal Closure Strips | 1.5.1 | G | ||||||||||||||
| 273 | 07 42 63 | 4 | Samples | Manufacturer's Color Charts And Chips | 1.5.1 | G | ||||||||||||||
| 274 | 07 42 63 | 5 | Design Data | Wind Design Analysis | 1.5.1 | |||||||||||||||
| 275 | 07 42 63 | 6 | Test Reports | Leakage Tests | 3.7.2 | G | ||||||||||||||
| 276 | 07 42 63 | 6 | Test Reports | Wind Load Tests | 1.3.2 | G | ||||||||||||||
| 277 | 07 42 63 | 6 | Test Reports | Seismic Tests | 1.3.2 | G | ||||||||||||||
| 278 | 07 42 63 | 6 | Test Reports | Factory Color Finish | 1.5.1 | G | ||||||||||||||
| 279 | 07 42 63 | 7 | Certificates | Fasteners | 1.5.1 | |||||||||||||||
| 280 | 07 42 63 | 7 | Certificates | Enamel Repair Paint | 1.5.1 | |||||||||||||||
| 281 | 07 42 63 | 7 | Certificates | Qualification of Manufacturer | 1.5.3 | |||||||||||||||
| 282 | 07 42 63 | 7 | Certificates | Qualification of Installer | 1.5.4 | |||||||||||||||
| 283 | 07 42 63 | 7 | Certificates | wall system assembly wind load and fire rating classification listings | 1.5.1 | |||||||||||||||
| 284 | 07 42 63 | 8 | Manufacturer’s Instructions | Installation of Wall Panels | 1.5.1 | |||||||||||||||
| 285 | 07 42 63 | 11 | Closeout Submittals | Instructions | 1.5.1 | |||||||||||||||
| 286 | 07 42 63 | 11 | Closeout Submittals | Safety Data Sheets | 1.5.1 | |||||||||||||||
| 287 | 07 42 63 | 11 | Closeout Submittals | 20 year 'No-Dollar-Limit' Warranty | 1.5.1 | |||||||||||||||
| 288 | 07 60 00 | 2 | Shop Drawings | Exposed Sheet Metal | 2.1.1 | G | ||||||||||||||
| 289 | 07 60 00 | 2 | Shop Drawings | Expansion Joints | 3.1.20 | G | ||||||||||||||
| 290 | 07 60 00 | 2 | Shop Drawings | Fasciae | 2.1.1 | G | ||||||||||||||
| 291 | 07 60 00 | 2 | Shop Drawings | Splash Pans | 3.1.16 | G | ||||||||||||||
| 292 | 07 60 00 | 2 | Shop Drawings | Base Flashing | 3.1.9 | G | ||||||||||||||
| 293 | 07 60 00 | 2 | Shop Drawings | Counterflashing | 3.1.10 | G | ||||||||||||||
| 294 | 07 60 00 | 2 | Shop Drawings | Flashing at Roof Penetrations and Equipment Supports | 3.1.21 | G | ||||||||||||||
| 295 | 07 60 00 | 2 | Shop Drawings | Reglets | 2.1.9 | G | ||||||||||||||
| 296 | 07 60 00 | 2 | Shop Drawings | Drip Edges | 3.1.14 | G | ||||||||||||||
| 297 | 07 60 00 | 2 | Shop Drawings | Open Valley Flashing | 3.1.17 | G | ||||||||||||||
| 298 | 07 60 00 | 2 | Shop Drawings | Eave Flashing | 3.1.18 | G | ||||||||||||||
| 299 | 07 60 00 | 3 | Product Data | Roof | 2.1.7 | G | ||||||||||||||
| 300 | 07 60 00 | 4 | Samples | Finish Samples | 1.4.2 | G | ||||||||||||||
| 301 | 07 60 00 | 8 | Manufacturer’s Instructions | Instructions for Installation | 1.4.3 | G | ||||||||||||||
| 302 | 07 60 00 | 8 | Manufacturer’s Instructions | Quality Control Plan | 3.5 | G | ||||||||||||||
| 303 | 07 60 00 | 10 | Operation and Maintenance Data | Cleaning and Maintenance | 1.4.3 | G | ||||||||||||||
| 304 | 07 84 00 | 2 | Shop Drawings | Firestopping System | 2.1 | G | ||||||||||||||
| 305 | 07 84 00 | 3 | Product Data | Firestopping Materials | 2.2 | G | ||||||||||||||
| 306 | 07 84 00 | 6 | Test Reports | Inspection | 3.3 | G | ||||||||||||||
| 307 | 07 84 00 | 7 | Certificates | Inspector Qualifications | 1.5.2 | |||||||||||||||
| 308 | 07 84 00 | 7 | Certificates | Firestopping Materials | 2.2 | |||||||||||||||
| 309 | 07 84 00 | 7 | Certificates | Installer Qualifications | 1.5.1 | G | ||||||||||||||
| 310 | 07 92 00 | 3 | Product Data | Sealants | 2.2 | |||||||||||||||
| 311 | 07 92 00 | 3 | Product Data | Primers | 2.3 | |||||||||||||||
| 312 | 07 92 00 | 3 | Product Data | Bond Breakers | 2.4 | |||||||||||||||
| 313 | 07 92 00 | 3 | Product Data | Backstops | 2.5 | |||||||||||||||
| 314 | 07 92 00 | 7 | Certificates | Indoor Air Quality | 1.4.1 | G | ||||||||||||||
| 315 | 07 92 00 | 7 | Certificates | Sealants | 2.2 | |||||||||||||||
| 316 | 07 92 00 | 11 | Closeout Submittals | Indoor Air Quality For Interior Sealants | 2.2.1 | S | ||||||||||||||
| 317 | 07 92 00 | 11 | Closeout Submittals | Indoor Air Quality For Interior Floor Joint Sealants | 2.2.3 | S | ||||||||||||||
| 318 | 08 11 13 | 2 | Shop Drawings | Doors | 2.1 | G | ||||||||||||||
| 319 | 08 11 13 | 2 | Shop Drawings | Doors | 2.1 | G | ||||||||||||||
| 320 | 08 11 13 | 2 | Shop Drawings | Frames | 2.4 | G | ||||||||||||||
| 321 | 08 11 13 | 2 | Shop Drawings | Frames | 2.4 | G | ||||||||||||||
| 322 | 08 11 13 | 2 | Shop Drawings | Accessories | 2.2 | |||||||||||||||
| 323 | 08 11 13 | 2 | Shop Drawings | Weatherstripping | 2.5 | |||||||||||||||
| 324 | 08 11 13 | 3 | Product Data | Doors | 2.1 | G | ||||||||||||||
| 325 | 08 11 13 | 3 | Product Data | Frames | 2.4 | G | ||||||||||||||
| 326 | 08 11 13 | 3 | Product Data | Accessories | 2.2 | |||||||||||||||
| 327 | 08 11 13 | 3 | Product Data | Weatherstripping | 2.5 | |||||||||||||||
| 328 | 08 33 23 | 2 | Shop Drawings | Overhead Coiling Doors | 2.2.1 | G | ||||||||||||||
| 329 | 08 33 23 | 2 | Shop Drawings | Counterbalancing Mechanism | 2.2.3 | G | ||||||||||||||
| 330 | 08 33 23 | 2 | Shop Drawings | Manual Door Operators | 2.2.4 | G | ||||||||||||||
| 331 | 08 33 23 | 2 | Shop Drawings | Electric Door Operators | 2.2.5 | G | ||||||||||||||
| 332 | 08 33 23 | 2 | Shop Drawings | Bottom Bars | 2.2.1.3 | G | ||||||||||||||
| 333 | 08 33 23 | 2 | Shop Drawings | Guides | 2.1.1.1 | G | ||||||||||||||
| 334 | 08 33 23 | 2 | Shop Drawings | Mounting Brackets | 2.2.3.1 | G | ||||||||||||||
| 335 | 08 33 23 | 2 | Shop Drawings | Overhead Drum | 2.2.1.8 | G | ||||||||||||||
| 336 | 08 33 23 | 2 | Shop Drawings | Hood | 3.3.2 | G | ||||||||||||||
| 337 | 08 33 23 | 2 | Shop Drawings | Installation Drawings | 2.1.1.1 | G | ||||||||||||||
| 338 | 08 33 23 | 3 | Product Data | Overhead Coiling Doors | 2.2.1 | G | ||||||||||||||
| 339 | 08 33 23 | 3 | Product Data | Hardware | 2.2.2 | G | ||||||||||||||
| 340 | 08 33 23 | 3 | Product Data | Counterbalancing Mechanism | 2.2.3 | G | ||||||||||||||
| 341 | 08 33 23 | 3 | Product Data | Manual Door Operators | 2.2.4 | G | ||||||||||||||
| 342 | 08 33 23 | 3 | Product Data | Electric Door Operators | 2.2.5 | G | ||||||||||||||
| 343 | 08 33 23 | 10 | Operation and Maintenance Data | Operation and Maintenance Manuals | 3.3.2 | |||||||||||||||
| 344 | 08 33 23 | 10 | Operation and Maintenance Data | Materials | 3.3.2 | G | ||||||||||||||
| 345 | 08 33 23 | 10 | Operation and Maintenance Data | Devices | 3.3.2 | G | ||||||||||||||
| 346 | 08 33 23 | 10 | Operation and Maintenance Data | Procedures | 3.3.2 | G | ||||||||||||||
| 347 | 08 33 23 | 10 | Operation and Maintenance Data | Manufacture's Brochures | 3.3.2 | G | ||||||||||||||
| 348 | 08 33 23 | 10 | Operation and Maintenance Data | Parts Lists | 3.3.2 | G | ||||||||||||||
| 349 | 08 33 23 | 11 | Closeout Submittals | Warranty | 3.3.1 | G | ||||||||||||||
| 350 | 08 71 00 | 2 | Shop Drawings | Manufacturer's Detail Drawings | 1.3 | G | ||||||||||||||
| 351 | 08 71 00 | 2 | Shop Drawings | Verification of Existing Conditions | 1.3 | G | ||||||||||||||
| 352 | 08 71 00 | 2 | Shop Drawings | Hardware Schedule | 1.5 | G | ||||||||||||||
| 353 | 08 71 00 | 2 | Shop Drawings | Keying System | 2.3.6 | G | ||||||||||||||
| 354 | 08 71 00 | 3 | Product Data | Hardware Items | 2.3 | G | ||||||||||||||
| 355 | 08 71 00 | 8 | Manufacturer’s Instructions | Installation | 3.1 | |||||||||||||||
| 356 | 08 71 00 | 10 | Operation and Maintenance Data | Hardware Schedule | 1.5 | G | ||||||||||||||
| 357 | 08 71 00 | 11 | Closeout Submittals | Key Bitting | 1.6.1 | |||||||||||||||
| 358 | 08 91 00 | 2 | Shop Drawings | Wall louvers | 1.4 | |||||||||||||||
| 359 | 08 91 00 | 2 | Shop Drawings | Wall louvers | 1.5 | |||||||||||||||
| 360 | 08 91 00 | 3 | Product Data | Metal Wall Louvers | 2.2 | |||||||||||||||
| 361 | 08 91 00 | 4 | Samples | Wall louvers | 1.4 | G | ||||||||||||||
| 362 | 08 91 00 | 4 | Samples | Wall louvers | 1.5 | G | ||||||||||||||
| 363 | 08 91 00 | 4 | Samples | Door louvers | 1.5 | G | ||||||||||||||
| 364 | 09 22 00 | 2 | Shop Drawings | Metal support systems | 2.1 | G | ||||||||||||||
| 365 | 09 29 00 | 3 | Product Data | Accessories | 2.2.4 | |||||||||||||||
| 366 | 09 29 00 | 3 | Product Data | Certifications | 1.3 | G | ||||||||||||||
| 367 | 09 29 00 | 3 | Product Data | Local/Regional Materials | S | |||||||||||||||
| 368 | 09 29 00 | 3 | Product Data | Environmental Data | ||||||||||||||||
| 369 | 09 29 00 | 7 | Certificates | Asbestos Free Materials | 2.2 | G | ||||||||||||||
| 370 | 09 29 00 | 7 | Certificates | Sustainable Design | 1.3.1 | G | ||||||||||||||
| 371 | 09 29 00 | 8 | Manufacturer’s Instructions | Safety Data Sheets | 2.2 | |||||||||||||||
| 372 | 09 29 00 | 8 | Manufacturer’s Instructions | Manufacturer Maintenance Instructions | 2.2 | |||||||||||||||
| 373 | 09 29 00 | 11 | Closeout Submittals | Local/Regional Materials | S | |||||||||||||||
| 374 | 09 29 00 | 11 | Closeout Submittals | Gypsum Board | 2.2.1 | S | ||||||||||||||
| 375 | 09 29 00 | 11 | Closeout Submittals | Adhesives | S | |||||||||||||||
| 376 | 09 96 00 | 1 | Preconstruction Submittals | Equipment List | 1.3 | |||||||||||||||
| 377 | 09 96 00 | 3 | Product Data | Heat-Resistant Coatings | 2.1.1 | |||||||||||||||
| 378 | 09 96 00 | 3 | Product Data | Epoxy Coatings | 2.2.1 | |||||||||||||||
| 379 | 09 96 00 | 3 | Product Data | Polyurethane Coatings | 2.2.2 | |||||||||||||||
| 380 | 09 96 00 | 4 | Samples | Color Chips | 1.3 | |||||||||||||||
| 381 | 09 96 00 | 7 | Certificates | Heat-Resistant Coatings | 2.1.1 | |||||||||||||||
| 382 | 09 96 00 | 7 | Certificates | Epoxy Coatings | 2.2.1 | |||||||||||||||
| 383 | 09 96 00 | 7 | Certificates | Polyurethane Coatings | 2.2.2 | |||||||||||||||
| 384 | 09 96 00 | 7 | Certificates | Manufacturer's Printed Instructions | 3.1.4 | |||||||||||||||
| 385 | 10 14 00.10 | 2 | Shop Drawings | Approved Detail Drawings | 3.1 | G | ||||||||||||||
| 386 | 10 14 00.10 | 3 | Product Data | Modular Exterior Signage System | 2.1 | |||||||||||||||
| 387 | 10 14 00.10 | 3 | Product Data | Installation | 3.1 | |||||||||||||||
| 388 | 10 14 00.10 | 3 | Product Data | Exterior Signage | 1.2 | G | ||||||||||||||
| 389 | 10 14 00.10 | 3 | Product Data | Wind Load Requirements | 1.2.1 | |||||||||||||||
| 390 | 10 14 00.10 | 4 | Samples | Exterior Signage | 1.2 | G | ||||||||||||||
| 391 | 10 14 00.10 | 10 | Operation and Maintenance Data | Protection and Cleaning | 3.1.2 | G | ||||||||||||||
| 392 | 10 14 00.20 | 2 | Shop Drawings | Detail Drawings | 1.4.2 | G | ||||||||||||||
| 393 | 10 14 00.20 | 3 | Product Data | Installation | 3.1 | G | ||||||||||||||
| 394 | 10 14 00.20 | 3 | Product Data | Warranty | 1.6 | G | ||||||||||||||
| 395 | 10 14 00.20 | 4 | Samples | Interior Signage | 1.4.1 | G | ||||||||||||||
| 396 | 10 14 00.20 | 4 | Samples | Software | 1.3 | G | ||||||||||||||
| 397 | 10 14 00.20 | 10 | Operation and Maintenance Data | Approved Manufacturer's Instructions | 3.1 | G | ||||||||||||||
| 398 | 10 14 00.20 | 10 | Operation and Maintenance Data | Protection and Cleaning | 3.1.2 | G | ||||||||||||||
| 399 | 10 28 13 | 3 | Product Data | Finishes | 2.1.2 | G | ||||||||||||||
| 400 | 10 28 13 | 3 | Product Data | Accessory Items | 2.2 | G | ||||||||||||||
| 401 | 10 28 13 | 4 | Samples | Finishes | 2.1.2 | G | ||||||||||||||
| 402 | 10 28 13 | 7 | Certificates | Accessory Items | 2.2 | |||||||||||||||
| 403 | 10 28 13 | 10 | Operation and Maintenance Data | Electric Hand Dryer | 2.2.11 | G | ||||||||||||||
| 404 | 10 28 13 | 11 | Closeout Submittals | Recycled content for stainless steel toilet accessories | 2.1 | S | ||||||||||||||
| 405 | 13 34 19 | 1 | Preconstruction Submittals | Manufacturer's Qualifications | 1.6.3 | G | ||||||||||||||
| 406 | 13 34 19 | 2 | Shop Drawings | Detail Drawings | 1.2.1.7 | G | ||||||||||||||
| 407 | 13 34 19 | 2 | Shop Drawings | Detail Drawings | 1.6.1 | G | ||||||||||||||
| 408 | 13 34 19 | 2 | Shop Drawings | Erection Plan | 1.2.10 | G | ||||||||||||||
| 409 | 13 34 19 | 3 | Product Data | Manufacturer's Catalog Data | 1.6.1 | G | ||||||||||||||
| 410 | 13 34 19 | 4 | Samples | Roof Panels | 1.2.1.9 | G | ||||||||||||||
| 411 | 13 34 19 | 4 | Samples | Wall Panels | 1.2.1.9 | G | ||||||||||||||
| 412 | 13 34 19 | 4 | Samples | Fasteners | 2.5.2 | G | ||||||||||||||
| 413 | 13 34 19 | 4 | Samples | Metal Closure Strips | 2.8.1 | G | ||||||||||||||
| 414 | 13 34 19 | 4 | Samples | Insulation | 1.4.7 | G | ||||||||||||||
| 415 | 13 34 19 | 4 | Samples | Insulation | 2.4.3 | G | ||||||||||||||
| 416 | 13 34 19 | 4 | Samples | Vapor Barrier | 1.6.10 | G | ||||||||||||||
| 417 | 13 34 19 | 4 | Samples | Manufacturer's Color Charts and Chips | 2.4.4 | G | ||||||||||||||
| 418 | 13 34 19 | 5 | Design Data | Manufacturer's Descriptive and Technical Literature | 1.6.1 | G | ||||||||||||||
| 419 | 13 34 19 | 5 | Design Data | Manufacturer's Building Design Analysis | 1.6.1 | G | ||||||||||||||
| 420 | 13 34 19 | 6 | Test Reports | Test Reports | 1.6.1 | G | ||||||||||||||
| 421 | 13 34 19 | 6 | Test Reports | Coatings and Base Metals | 1.6.1 | G | ||||||||||||||
| 422 | 13 34 19 | 6 | Test Reports | Factory Color Finish Performance Requirements | 1.6.1 | G | ||||||||||||||
| 423 | 13 34 19 | 7 | Certificates | System Components | 1.6.1 | G | ||||||||||||||
| 424 | 13 34 19 | 7 | Certificates | Coil Stock | 1.6.1 | G | ||||||||||||||
| 425 | 13 34 19 | 7 | Certificates | Aluminized Steel Repair Paint | 1.6.1 | G | ||||||||||||||
| 426 | 13 34 19 | 7 | Certificates | Galvanizing Repair Paint | 1.6.1 | G | ||||||||||||||
| 427 | 13 34 19 | 7 | Certificates | Enamel Repair Paint | 1.6.1 | G | ||||||||||||||
| 428 | 13 34 19 | 7 | Certificates | Qualification of Manufacturer | 1.6.1 | G | ||||||||||||||
| 429 | 13 34 19 | 7 | Certificates | Qualification of Erector | 1.6.1 | G | ||||||||||||||
| 430 | 13 34 19 | 8 | Manufacturer’s Instructions | Installation of Roof and Wall panels | 1.6.2 | G | ||||||||||||||
| 431 | 13 34 19 | 8 | Manufacturer’s Instructions | Shipping, Handling, and Storage | 1.7 | G | ||||||||||||||
| 432 | 13 34 19 | 11 | Closeout Submittals | Manufacturer's Warranty | 3.14.1 | G | ||||||||||||||
| 433 | 13 34 19 | 11 | Closeout Submittals | Contractor's Warranty for Installation | 3.14.2 | G | ||||||||||||||
| 434 | 13 48 00 | 2 | Shop Drawings | Bracing | 3.1 | G | ||||||||||||||
| 435 | 13 48 00 | 2 | Shop Drawings | Resilient Vibration Isolation Devices | 3.4 | G | ||||||||||||||
| 436 | 13 48 00 | 2 | Shop Drawings | Equipment Requirements | 2.1 | G | ||||||||||||||
| 437 | 13 48 00 | 3 | Product Data | Bracing | 3.1 | G | ||||||||||||||
| 438 | 13 48 00 | 3 | Product Data | Equipment Requirements | 2.1 | G | ||||||||||||||
| 439 | 13 48 00 | 3 | Product Data | Anchor Bolts | 3.3 | G | ||||||||||||||
| 440 | 13 48 00 | 3 | Product Data | Vibration Isolators | 2.1.2 | G | ||||||||||||||
| 441 | 13 48 00 | 3 | Product Data | Snubbers | 3.4.2 | G | ||||||||||||||
| 442 | 13 48 00 | 5 | Design Data | Design Calculations | 1.2.3 | G | ||||||||||||||
| 443 | 13 48 00 | 6 | Test Reports | Anchor Bolts | 3.3 | G | ||||||||||||||
| 444 | 13 48 00 | 7 | Certificates | ICC ES AC156 Shake Table Test | 3.6 | G | ||||||||||||||
| 445 | 21 13 13 | 2 | Shop Drawings | Shop Drawings | 1.4.3 | G | ||||||||||||||
| 446 | 21 13 13 | 2 | Shop Drawings | As-Built Drawings | 3.9 | |||||||||||||||
| 447 | 21 13 13 | 3 | Product Data | Fire Protection Related Submittals | 1.4.1 | |||||||||||||||
| 448 | 21 13 13 | 3 | Product Data | Materials and Equipment | 2.3 | G | ||||||||||||||
| 449 | 21 13 13 | 3 | Product Data | Spare Parts | 1.6 | |||||||||||||||
| 450 | 21 13 13 | 3 | Product Data | Preliminary Tests | 3.8 | G | ||||||||||||||
| 451 | 21 13 13 | 3 | Product Data | Final Acceptance Test | 3.9 | G | ||||||||||||||
| 452 | 21 13 13 | 3 | Product Data | Onsite Training | 3.11 | G | ||||||||||||||
| 453 | 21 13 13 | 3 | Product Data | Fire Protection Specialist | 1.4.1 | G | ||||||||||||||
| 454 | 21 13 13 | 3 | Product Data | Sprinkler System Installer | 1.4.2 | G | ||||||||||||||
| 455 | 21 13 13 | 5 | Design Data | Sway Bracing | 1.4.3 | G | ||||||||||||||
| 456 | 21 13 13 | 5 | Design Data | Hydraulic Calculations | 1.2.1.3 | G | ||||||||||||||
| 457 | 21 13 13 | 6 | Test Reports | Preliminary Test Report | 3.8 | |||||||||||||||
| 458 | 21 13 13 | 6 | Test Reports | Final Acceptance Test Report | 3.9 | |||||||||||||||
| 459 | 21 13 13 | 7 | Certificates | Inspection by Fire Protection Specialist | 3.3 | |||||||||||||||
| 460 | 21 13 13 | 10 | Operation and Maintenance Data | Operating and Maintenance Manuals | 3.11 | G | ||||||||||||||
| 461 | 22 00 00 | 2 | Shop Drawings | Plumbing System | 3.8.1 | G | ||||||||||||||
| 462 | 22 00 00 | 3 | Product Data | Recycled Content for Cast Iron Pipe | 2.1 | S | ||||||||||||||
| 463 | 22 00 00 | 3 | Product Data | Fixtures | ||||||||||||||||
| 464 | 22 00 00 | 3 | Product Data | Water Heaters | 2.6 | G | ||||||||||||||
| 465 | 22 00 00 | 3 | Product Data | Backflow Prevention Assemblies | 3.8.1.1 | G | ||||||||||||||
| 466 | 22 00 00 | 3 | Product Data | Vibration-Absorbing Features | G | |||||||||||||||
| 467 | 22 00 00 | 3 | Product Data | Plumbing System | 3.8.1 | |||||||||||||||
| 468 | 22 00 00 | 6 | Test Reports | Tests, Flushing and Disinfection | 3.8 | |||||||||||||||
| 469 | 22 00 00 | 6 | Test Reports | Test of Backflow Prevention Assemblies | 3.8.1.1 | G | ||||||||||||||
| 470 | 22 00 00 | 7 | Certificates | Materials and Equipment | 1.3 | |||||||||||||||
| 471 | 22 00 00 | 7 | Certificates | Bolts | 2.1.1 | |||||||||||||||
| 472 | 22 00 00 | 10 | Operation and Maintenance Data | Plumbing System | 3.8.1 | G | ||||||||||||||
| 473 | 22 15 26 | 3 | Product Data | Air Compressor | 2.1 | G | ||||||||||||||
| 474 | 22 15 26 | 3 | Product Data | Air receivers | 2.2 | G | ||||||||||||||
| 475 | 22 15 26 | 3 | Product Data | Desiccant Air Dryers | 2.3 | G | ||||||||||||||
| 476 | 22 15 26 | 3 | Product Data | Oil/Water Separator | 2.11 | G | ||||||||||||||
| 477 | 22 15 26 | 3 | Product Data | Fittings | 2.4.2 | |||||||||||||||
| 478 | 22 15 26 | 3 | Product Data | Valves | 2.4.6 | |||||||||||||||
| 479 | 22 15 26 | 3 | Product Data | Electronic No Loss Drain | 2.4.10.1 | G | ||||||||||||||
| 480 | 22 15 26 | 3 | Product Data | Traps | 2.4.10 | |||||||||||||||
| 481 | 22 15 26 | 3 | Product Data | Flexible connections | 2.4.11 | |||||||||||||||
| 482 | 22 15 26 | 3 | Product Data | Identification labels for piping | 2.6 | |||||||||||||||
| 483 | 22 15 26 | 6 | Test Reports | Non-Destructive Examination (NDE) report for welding of piping | 3.1.2 | |||||||||||||||
| 484 | 22 15 26 | 6 | Test Reports | Leak tightness test | 3.2.2.2 | |||||||||||||||
| 485 | 22 15 26 | 7 | Certificates | Employer's record documents | 1.4.3 | |||||||||||||||
| 486 | 22 15 26 | 7 | Certificates | Welding procedures and qualifications | 1.4.4 | |||||||||||||||
| 487 | 22 15 26 | 8 | Manufacturer’s Instructions | Air receivers | 2.2 | |||||||||||||||
| 488 | 22 15 26 | 10 | Operation and Maintenance Data | Air compressor | 2.1 | |||||||||||||||
| 489 | 22 15 26 | 10 | Operation and Maintenance Data | Desiccant Air Dryers | 2.3 | |||||||||||||||
| 490 | 22 15 26 | 10 | Operation and Maintenance Data | Oil/Water Separator | 2.11 | G | ||||||||||||||
| 491 | 22 15 26 | 11 | Closeout Submittals | air compressor | 2.1 | |||||||||||||||
| 492 | 22 15 26 | 11 | Closeout Submittals | Desiccant air dryer | ||||||||||||||||
| 493 | 22 15 26 | 11 | Closeout Submittals | compressed air systems | 1.4 | |||||||||||||||
| 494 | 23 00 00 | 2 | Shop Drawings | Detail Drawings | 1.4.3 | G | ||||||||||||||
| 495 | 23 00 00 | 3 | Product Data | Diffusers | 2.8.3 | |||||||||||||||
| 496 | 23 00 00 | 3 | Product Data | Registers and Grilles | 2.8.3.1 | |||||||||||||||
| 497 | 23 00 00 | 3 | Product Data | Centrifugal Fans | 2.9.1.1 | |||||||||||||||
| 498 | 23 00 00 | 3 | Product Data | In-Line Centrifugal Fans | 2.9.1.2 | |||||||||||||||
| 499 | 23 00 00 | 3 | Product Data | Panel Type Power Wall Ventilators | 2.9.1.3 | |||||||||||||||
| 500 | 23 00 00 | 6 | Test Reports | Performance Tests | 3.9 | G | ||||||||||||||
| 501 | 23 00 00 | 7 | Certificates | Bolts | 1.4.1 | |||||||||||||||
| 502 | 23 00 00 | 8 | Manufacturer’s Instructions | Manufacturer's Installation Instructions | 3.2 | |||||||||||||||
| 503 | 23 00 00 | 8 | Manufacturer’s Instructions | Operation and Maintenance Training | 3.11.2 | |||||||||||||||
| 504 | 23 00 00 | 10 | Operation and Maintenance Data | Operation and Maintenance Manuals | 3.11.1 | G | ||||||||||||||
| 505 | 23 00 00 | 10 | Operation and Maintenance Data | In-Line Centrifugal Fans | 2.9.1.2 | G | ||||||||||||||
| 506 | 23 00 00 | 10 | Operation and Maintenance Data | Panel Type Power Wall Ventilators | 2.9.1.3 | G | ||||||||||||||
| 507 | 23 00 00 | 11 | Closeout Submittals | Indoor Air Quality During Construction | 3.1 | S | ||||||||||||||
| 508 | 23 05 15 | 3 | Product Data | Electrical Heat Tracing | 2.1 | G | ||||||||||||||
| 509 | 23 05 15 | 7 | Certificates | Record of Satisfactory Field Operation | 1.4.2 | |||||||||||||||
| 510 | 23 05 15 | 7 | Certificates | List of Qualified Permanent Service Organizations | 1.4.3 | |||||||||||||||
| 511 | 23 05 15 | 10 | Operation and Maintenance Data | Operation and Maintenance Manuals | 3.3 | G | ||||||||||||||
| 512 | 23 05 48 | 2 | Shop Drawings | Installation Drawings | 1.2 | G | ||||||||||||||
| 513 | 23 05 48 | 2 | Shop Drawings | Outline Drawings | 1.2 | G | ||||||||||||||
| 514 | 23 05 48 | 3 | Product Data | Equipment and Performance Data | 1.2 | G | ||||||||||||||
| 515 | 23 05 48 | 3 | Product Data | Isolators | 2.2.2 | G | ||||||||||||||
| 516 | 23 05 48 | 6 | Test Reports | Type of Isolator | 2.4 | G | ||||||||||||||
| 517 | 23 05 48 | 6 | Test Reports | Type of Base | 2.4 | G | ||||||||||||||
| 518 | 23 05 48 | 6 | Test Reports | Allowable Deflection | 2.4 | G | ||||||||||||||
| 519 | 23 05 48 | 6 | Test Reports | Measured Deflection | 2.4 | G | ||||||||||||||
| 520 | 23 05 48.19 | 2 | Shop Drawings | Coupling and Bracing | 3.1 | |||||||||||||||
| 521 | 23 05 48.19 | 2 | Shop Drawings | Flexible Couplings or Joints | 3.3 | |||||||||||||||
| 522 | 23 05 48.19 | 2 | Shop Drawings | Equipment Restraint | 2.2 | |||||||||||||||
| 523 | 23 05 48.19 | 2 | Shop Drawings | Contractor Designed Bracing | 1.2.4 | G | ||||||||||||||
| 524 | 23 05 48.19 | 3 | Product Data | Coupling and Bracing | 3.1 | G | ||||||||||||||
| 525 | 23 05 48.19 | 3 | Product Data | Flexible Couplings Or Joints | 3.3 | G | ||||||||||||||
| 526 | 23 05 48.19 | 3 | Product Data | Equipment Restraint | 2.2 | G | ||||||||||||||
| 527 | 23 05 48.19 | 3 | Product Data | Contractor Designed Bracing | 1.2.4 | G | ||||||||||||||
| 528 | 23 05 48.19 | 3 | Product Data | Anchor Bolts | 3.9 | |||||||||||||||
| 529 | 23 05 48.19 | 3 | Product Data | Vibration Isolators | 2.2.2 | |||||||||||||||
| 530 | 23 05 48.19 | 5 | Design Data | Design Calculations | 1.2.4 | |||||||||||||||
| 531 | 23 05 48.19 | 6 | Test Reports | Anchor Bolts | 3.9 | G | ||||||||||||||
| 532 | 23 05 93 | 1 | Preconstruction Submittals | Independent TAB Agency and Personnel Qualifications | 1.5.1 | G | ||||||||||||||
| 533 | 23 05 93 | 1 | Preconstruction Submittals | TAB Design Review Report | 1.6.1.1 | G | ||||||||||||||
| 534 | 23 05 93 | 1 | Preconstruction Submittals | TAB Firm | 1.5.7.1 | G | ||||||||||||||
| 535 | 23 05 93 | 1 | Preconstruction Submittals | TAB Team Assistants | 1.2 | G | ||||||||||||||
| 536 | 23 05 93 | 1 | Preconstruction Submittals | TAB Team Engineer | 1.2 | G | ||||||||||||||
| 537 | 23 05 93 | 1 | Preconstruction Submittals | TAB Specialist | 1.5.7.2 | G | ||||||||||||||
| 538 | 23 05 93 | 1 | Preconstruction Submittals | TAB Team Field Leader | 1.2 | G | ||||||||||||||
| 539 | 23 05 93 | 2 | Shop Drawings | TAB Schematic Drawings and Report Forms | 1.3.2 | G | ||||||||||||||
| 540 | 23 05 93 | 3 | Product Data | Equipment and Performance Data | 1.3 | G | ||||||||||||||
| 541 | 23 05 93 | 3 | Product Data | TAB Related HVAC Submittals | 1.5.1.3 | G | ||||||||||||||
| 542 | 23 05 93 | 3 | Product Data | TAB Related HVAC Submittals | 1.5.7.4 | G | ||||||||||||||
| 543 | 23 05 93 | 3 | Product Data | TAB Procedures | 1.5.5 | G | ||||||||||||||
| 544 | 23 05 93 | 3 | Product Data | Calibration | 1.5.5 | G | ||||||||||||||
| 545 | 23 05 93 | 3 | Product Data | Systems Readiness Check | 1.3.2 | G | ||||||||||||||
| 546 | 23 05 93 | 3 | Product Data | TAB Execution | 1.5.2 | G | ||||||||||||||
| 547 | 23 05 93 | 3 | Product Data | TAB Verification | 1.5.2.3 | G | ||||||||||||||
| 548 | 23 05 93 | 6 | Test Reports | Completed Pre-Final DALT Report | 3.3.5 | G | ||||||||||||||
| 549 | 23 05 93 | 6 | Test Reports | Certified Final DALT Report | 3.3.8 | G | ||||||||||||||
| 550 | 23 05 93 | 6 | Test Reports | Prerequisite HVAC Work Checkout List | 1.6.1.3 | G | ||||||||||||||
| 551 | 23 05 93 | 6 | Test Reports | Prerequisite HVAC Work Checkout List | 1.6.1.3 | G | ||||||||||||||
| 552 | 23 05 93 | 6 | Test Reports | Prerequisite HVAC Work Checkout List | 1.6.1.3 | G | ||||||||||||||
| 553 | 23 05 93 | 6 | Test Reports | Proportional Balancing | 3.4.4.1 | G | ||||||||||||||
| 554 | 23 05 93 | 6 | Test Reports | Proportional Balancing | 3.7 | G | ||||||||||||||
| 555 | 23 05 93 | 6 | Test Reports | Season 1 | 3.4.4.2 | G | ||||||||||||||
| 556 | 23 05 93 | 6 | Test Reports | Season 1 | 3.7 | G | ||||||||||||||
| 557 | 23 05 93 | 6 | Test Reports | Season 2 | 3.4.4.2 | G | ||||||||||||||
| 558 | 23 05 93 | 6 | Test Reports | Season 2 | 3.7 | G | ||||||||||||||
| 559 | 23 05 93 | 6 | Test Reports | TAB Design Review Report | 1.6.1.1 | G | ||||||||||||||
| 560 | 23 05 93 | 6 | Test Reports | TAB Report for Season 1 | 1.5.8.2 | G | ||||||||||||||
| 561 | 23 05 93 | 6 | Test Reports | TAB Report for Season 2 | 1.5.8.2 | G | ||||||||||||||
| 562 | 23 05 93 | 6 | Test Reports | FET System Performance Verification Report; | G | |||||||||||||||
| 563 | 23 05 93 | 7 | Certificates | Independent TAB Agency and Personnel Qualifications | 1.5.1 | G | ||||||||||||||
| 564 | 23 05 93 | 7 | Certificates | DALT and TAB Submittal and Work Schedule | 1.6.1 | G | ||||||||||||||
| 565 | 23 05 93 | 7 | Certificates | TAB Pre-Field Engineering Report | 1.6.1.3 | G | ||||||||||||||
| 566 | 23 05 93 | 7 | Certificates | Instrument Calibration Certificates | 1.5.4 | G | ||||||||||||||
| 567 | 23 05 93 | 7 | Certificates | DALT and TAB Procedures Summary | 3.7 | G | ||||||||||||||
| 568 | 23 05 93 | 7 | Certificates | Completed Pre-Final DALT Work Checklist | 3.7 | G | ||||||||||||||
| 569 | 23 05 93 | 7 | Certificates | Advance Notice of Pre-Final DALT Field Work | 3.3.2 | G | ||||||||||||||
| 570 | 23 05 93 | 7 | Certificates | Proportional Balancing | 3.4.4.1 | G | ||||||||||||||
| 571 | 23 05 93 | 7 | Certificates | Proportional Balancing | 3.7 | G | ||||||||||||||
| 572 | 23 05 93 | 7 | Certificates | Season 1 | 3.4.4.2 | G | ||||||||||||||
| 573 | 23 05 93 | 7 | Certificates | Season 1 | 3.7 | G | ||||||||||||||
| 574 | 23 05 93 | 7 | Certificates | Season 2 | 3.4.4.2 | G | ||||||||||||||
| 575 | 23 05 93 | 7 | Certificates | Season 2 | 3.7 | G | ||||||||||||||
| 576 | 23 05 93 | 7 | Certificates | TAB Firm | 1.5.7.1 | G | ||||||||||||||
| 577 | 23 05 93 | 7 | Certificates | Design Review Report | 1.3.2 | G | ||||||||||||||
| 578 | 23 05 93 | 7 | Certificates | Pre-field DALT Preliminary Notification | 1.6.1.2 | G | ||||||||||||||
| 579 | 23 05 93 | 7 | Certificates | Advanced Notice for Season 1 TAB Field Work | 1.6.1 | G | ||||||||||||||
| 580 | 23 05 93 | 7 | Certificates | Prerequisite HVAC Work Check Out List For Season 1 | 1.6.1 | G | ||||||||||||||
| 581 | 23 05 93 | 7 | Certificates | Advanced Notice for Season 2 TAB Field Work | 1.6.1 | G | ||||||||||||||
| 582 | 23 05 93 | 7 | Certificates | Prerequisite HVAC Work Check Out List For Season 2 | 1.6.1 | G | ||||||||||||||
| 583 | 23 07 00 | 2 | Shop Drawings | MICA Plates | 3.2.2.4 | G | ||||||||||||||
| 584 | 23 07 00 | 2 | Shop Drawings | Pipe Insulation Systems | 2.3 | |||||||||||||||
| 585 | 23 07 00 | 2 | Shop Drawings | Pipe Insulation Systems | 3.2 | |||||||||||||||
| 586 | 23 07 00 | 2 | Shop Drawings | Duct Insulation Systems | 3.3 | |||||||||||||||
| 587 | 23 07 00 | 2 | Shop Drawings | Recycled content for insulation materials | 2.3.1 | S | ||||||||||||||
| 588 | 23 07 00 | 3 | Product Data | Pipe Insulation Systems | 2.3 | G | ||||||||||||||
| 589 | 23 07 00 | 3 | Product Data | Pipe Insulation Systems | 3.2 | G | ||||||||||||||
| 590 | 23 07 00 | 3 | Product Data | Duct Insulation Systems | 3.3 | G | ||||||||||||||
| 591 | 23 07 00 | 3 | Product Data | Equipment Insulation Systems | 3.4 | G | ||||||||||||||
| 592 | 23 07 00 | 4 | Samples | Thermal Insulation | 2.2.1.2 | G | ||||||||||||||
| 593 | 23 07 00 | 4 | Samples | Display Samples | 3.1.1 | G | ||||||||||||||
| 594 | 23 07 00 | 7 | Certificates | Indoor air quality for adhesives | 2.2.1 | S | ||||||||||||||
| 595 | 23 07 00 | 8 | Manufacturer’s Instructions | Pipe Insulation Systems | 2.3 | G | ||||||||||||||
| 596 | 23 07 00 | 8 | Manufacturer’s Instructions | Pipe Insulation Systems | 3.2 | G | ||||||||||||||
| 597 | 23 07 00 | 8 | Manufacturer’s Instructions | Duct Insulation Systems | 3.3 | G | ||||||||||||||
| 598 | 23 07 00 | 8 | Manufacturer’s Instructions | Equipment Insulation Systems | 3.4 | G | ||||||||||||||
| 599 | 23 09 00 | 2 | Shop Drawings | DDC Contractor Design Drawings | 3.3 | G | ||||||||||||||
| 600 | 23 09 00 | 2 | Shop Drawings | Draft As-Built Drawings | 3.3 | G | ||||||||||||||
| 601 | 23 09 00 | 2 | Shop Drawings | Final As-Built Drawings | 3.3 | G | ||||||||||||||
| 602 | 23 09 00 | 3 | Product Data | Controller Application Programs | 1.8.4 | G | ||||||||||||||
| 603 | 23 09 00 | 3 | Product Data | Manufacturer's Product Data | 2.2 | G | ||||||||||||||
| 604 | 23 09 00 | 6 | Test Reports | Start-Up Testing Report | 3.5.2 | G | ||||||||||||||
| 605 | 23 09 00 | 6 | Test Reports | PVT Procedures | 3.6.1 | G | ||||||||||||||
| 606 | 23 09 00 | 6 | Test Reports | PVT Report | 3.6.3 | G | ||||||||||||||
| 607 | 23 09 00 | 6 | Test Reports | Pre-Construction Quality Control (QC) Checklist | 1.9.1 | G | ||||||||||||||
| 608 | 23 09 00 | 6 | Test Reports | Post-Construction Quality Control (QC) Checklist | 1.9.2 | G | ||||||||||||||
| 609 | 23 09 00 | 10 | Operation and Maintenance Data | Operation and Maintenance (O&M) Instructions | 3.7 | G | ||||||||||||||
| 610 | 23 09 00 | 10 | Operation and Maintenance Data | Training Documentation | 3.9.1 | G | ||||||||||||||
| 611 | 23 09 00 | 11 | Closeout Submittals | Closeout Quality Control (QC) Checklist | 1.9.3 | G | ||||||||||||||
| 612 | 23 11 25 | 2 | Shop Drawings | Gas Piping System | 1.5.3 | G | ||||||||||||||
| 613 | 23 11 25 | 2 | Shop Drawings | Gas Piping System | 2.2 | G | ||||||||||||||
| 614 | 23 11 25 | 2 | Shop Drawings | Gas Piping System | 3.3 | G | ||||||||||||||
| 615 | 23 11 25 | 3 | Product Data | Pipe and Fittings | 1.6.1 | G | ||||||||||||||
| 616 | 23 11 25 | 3 | Product Data | Gas Equipment Connectors | 1.5.3 | G | ||||||||||||||
| 617 | 23 11 25 | 3 | Product Data | Gas Piping System | 1.5.3 | G | ||||||||||||||
| 618 | 23 11 25 | 3 | Product Data | Gas Piping System | 2.2 | G | ||||||||||||||
| 619 | 23 11 25 | 3 | Product Data | Gas Piping System | 3.3 | G | ||||||||||||||
| 620 | 23 11 25 | 3 | Product Data | Pipe Coating Materials | 2.1 | G | ||||||||||||||
| 621 | 23 11 25 | 3 | Product Data | Pressure Regulators | 2.7.1 | G | ||||||||||||||
| 622 | 23 11 25 | 3 | Product Data | Risers | 2.4 | G | ||||||||||||||
| 623 | 23 11 25 | 3 | Product Data | Transition Fittings | 2.2.8 | G | ||||||||||||||
| 624 | 23 11 25 | 3 | Product Data | Valves | 2.3 | G | ||||||||||||||
| 625 | 23 11 25 | 3 | Product Data | Warning and Identification Tape | 2.2.5 | G | ||||||||||||||
| 626 | 23 11 25 | 3 | Product Data | Meters | 2.7.2 | G | ||||||||||||||
| 627 | 23 11 25 | 6 | Test Reports | Testing | 3.15 | G | ||||||||||||||
| 628 | 23 11 25 | 6 | Test Reports | Pressure Tests | 3.15.1 | G | ||||||||||||||
| 629 | 23 11 25 | 6 | Test Reports | Test with Gas | 3.15.2 | G | ||||||||||||||
| 630 | 23 11 25 | 7 | Certificates | Welders Procedures and Qualifications | 1.5.1 | G | ||||||||||||||
| 631 | 23 11 25 | 7 | Certificates | Assigned Number, Letter, or Symbol | 1.5.1 | G | ||||||||||||||
| 632 | 23 11 25 | 8 | Manufacturer’s Instructions | PE Pipe and Fittings | 1.5.2 | G | ||||||||||||||
| 633 | 23 11 25 | 8 | Manufacturer’s Instructions | Pipe Coating Materials | 2.1 | G | ||||||||||||||
| 634 | 23 11 25 | 10 | Operation and Maintenance Data | Gas Facility System and Equipment Operation | 1.3.1 | G | ||||||||||||||
| 635 | 23 11 25 | 10 | Operation and Maintenance Data | Gas Facility System Maintenance | 1.3.2 | G | ||||||||||||||
| 636 | 23 11 25 | 10 | Operation and Maintenance Data | Gas Facility Equipment Maintenance | 1.3.3 | G | ||||||||||||||
| 637 | 23 23 00 | 2 | Shop Drawings | Refrigerant Piping System | 2.2 | G | ||||||||||||||
| 638 | 23 23 00 | 3 | Product Data | Refrigerant Piping System | 2.2 | |||||||||||||||
| 639 | 23 23 00 | 3 | Product Data | Spare Parts | 1.5.2 | |||||||||||||||
| 640 | 23 23 00 | 3 | Product Data | Qualifications | 1.3.1 | |||||||||||||||
| 641 | 23 23 00 | 3 | Product Data | Refrigerant Piping Tests | 3.5 | |||||||||||||||
| 642 | 23 23 00 | 3 | Product Data | Verification of Dimensions | 3.1 | |||||||||||||||
| 643 | 23 23 00 | 6 | Test Reports | Refrigerant Piping Tests | 3.5 | |||||||||||||||
| 644 | 23 23 00 | 7 | Certificates | Service Organization | 2.1 | |||||||||||||||
| 645 | 23 23 00 | 10 | Operation and Maintenance Data | Maintenance | 1.5 | G | ||||||||||||||
| 646 | 23 23 00 | 10 | Operation and Maintenance Data | Operation and Maintenance Manuals | 3.4 | G | ||||||||||||||
| 647 | 23 23 00 | 10 | Operation and Maintenance Data | Demonstrations | 3.4 | G | ||||||||||||||
| 648 | 23 31 13 | 1 | Preconstruction Submittals | Material, Equipment, and Fixture Lists | Part 2 | G | ||||||||||||||
| 649 | 23 31 13 | 2 | Shop Drawings | Connection Diagrams | 2.1 | G | ||||||||||||||
| 650 | 23 31 13 | 2 | Shop Drawings | Offset Fitting Configurations | 2.2.1 | G | ||||||||||||||
| 651 | 23 31 13 | 3 | Product Data | Galvanized Steel Ductwork Materials | 2.3.1 | G | ||||||||||||||
| 652 | 23 31 13 | 3 | Product Data | Brazing Materials | 2.3.2 | |||||||||||||||
| 653 | 23 31 13 | 3 | Product Data | Mill-Rolled Reinforcing and Supporting Materials | 2.3.3 | |||||||||||||||
| 654 | 23 31 13 | 3 | Product Data | Round Sheet Metal Duct Fittings | 2.2.1 | G | ||||||||||||||
| 655 | 23 31 13 | 3 | Product Data | Round, High-Pressure, Double-Wall Sheet Metal Ducts | 2.2.2 | G | ||||||||||||||
| 656 | 23 31 13 | 3 | Product Data | Turning Vanes | 2.2.5 | G | ||||||||||||||
| 657 | 23 31 13 | 3 | Product Data | Flexible Connectors | 2.2.7 | G | ||||||||||||||
| 658 | 23 31 13 | 3 | Product Data | Motor Operated Dampers | 2.2.12 | G | ||||||||||||||
| 659 | 23 31 13 | 3 | Product Data | Gravity Backdraft and Relief Dampers | 2.2.11 | G | ||||||||||||||
| 660 | 23 31 13 | 3 | Product Data | Manual Volume Dampers | 2.2.10 | G | ||||||||||||||
| 661 | 23 31 13 | 6 | Test Reports | Ductwork Leakage Tests | 3.4.1 | G | ||||||||||||||
| 662 | 23 31 13 | 7 | Certificates | Listing of Product Installations | 1.3 | |||||||||||||||
| 663 | 23 31 13 | 7 | Certificates | Galvanized Steel Ductwork Materials | 2.3.1 | |||||||||||||||
| 664 | 23 31 13 | 7 | Certificates | Brazing Materials | 2.3.2 | |||||||||||||||
| 665 | 23 31 13 | 7 | Certificates | Mill-Rolled Reinforcing and Supporting Materials | 2.3.3 |
This is the start of the file's text. The full file is on GovTribe.