About this file

This document includes a finish schedule and related federal contract opportunity notice. The finish schedule provides specifications for interior finishes for 161 rooms in a DLA Aviation Operations Center, including flooring, wall, ceiling, and base materials and finishes. The related federal contract opportunity is a pre-solicitation notice for construction of the DLA Aviation Operations Center Phase II, a 281,075 square foot office building in Richmond, Virginia estimated between $25-100 million. The notice provides details on the project scope, evaluation criteria, anticipated award as a firm-fixed price contract, and the May 27, 2020 posting date for the full RFP on SAM.gov.

View the file

Other files

File Type Posted
W91236-20-R-2005 Amendment 4 DLA Ops Center.pdf PDF
DLA Ops Center CLIN Schedule Rev1.pdf PDF
Attachment 73_DLA_OPS_PH II_A-119 - FOURTH FLOOR PLAN - AREA A4.pdf PDF
Attachment 66 _DLA_OPS_PH II_A-106 - FIRST FLOOR PLAN - AREA A1.pdf PDF
Attachment85_DLA_OPS_PH II_A-421 - ENLARGED METROLOGY LAB AND MYLAR ROOM PLAN.pdf PDF
Attachment91_DLA_OPS_PH II_A-602 - DOOR SCHEDULE.pdf PDF
Attachment95_DLA_OPS_PH II_A-703 - FINISH SCHEDULE.pdf PDF
Attachment 74_DLA_OPS_PH II_A-120 - FOURTH FLOOR PLAN - AREA D4.pdf PDF
Attachment 122 Spec-Drawing List 07-08-20.xlsx XLSX spreadsheet
Attachment129_DLA_OPS_PH II_321216 SPECIFICATIONS VOL2-Asphalt.pdf PDF
Attachment116_DLA_OPS_PH II_S-603 - COLUMN SCHEDULE.pdf PDF
Attachment80_DLA_OPS_PH II_A-206 - ENLARGED ELEVATIONS.pdf PDF
Attachment 71_DLA_OPS_PH II_A-117 - THIRD FLOOR PLAN - AREA A3.pdf PDF
Attachment 69_DLA_OPS_PH II_A-114 - SECOND FLOOR PLAN - AREA D2.pdf PDF
Attachment 127_DLA_OPS_PH II_316329 SPECIFICATIONS VOL2-Page1.pdf PDF
Attachment105_DLA_OPS_PH II_S-118 - SECOND FLOOR FRAMING PLAN - AREA F.pdf PDF
Attachment 62_DLA OPS_PH II_V-101.pdf PDF
Attachment108_DLA_OPS_PH II_S-132 - STAIRWELL FRAMING PLANS - AREA D.pdf PDF
Attachment122_OpsCtrPhaseII_final_GeotechRpt_Sept2019.pdf PDF
Attachment 65_DLA_OPS_PH II_A-103 - OVERALL THIRD FLOOR PLAN.pdf PDF
Attachment89_DLA_OPS_PH II_A-527 - MISCELLANEOUS DETAILS.pdf PDF
Attachment 58_DLA OPS_CU101-CU102.pdf PDF
Attachment102_DLA_OPS_PH II_S-104 - DRILLED PIER AND PIER CAP PLAN - AREA G.pdf PDF
Attachment124_DLA_OPS_PH II_087100 SPECIFICATIONS VOL1-Door Hardware.pdf PDF
Attachment109_DLA_OPS_PH II_S-133 - STAIRWELL AND ELEVATOR ROOF FRAMING PLANS - AREA D.pdf PDF
Attachment77_DLA_OPS_PH II_A-145 - PARTIAL LOW LEVEL ROOF PLAN.pdf PDF
Attachment82_DLA_OPS_PH II_A-208 - ENLARGED ELEVATIONS.pdf PDF
Final W91236-20-R-2005 Amendment 3 DLA Ops Center.pdf PDF
Attachment93_DLA_OPS_PH II_A-701 - FINISH SCHEDULE.pdf PDF
Attachment 59_DLA OPS_PH II_C-512.pdf PDF
Attachment90_DLA_OPS_PH II_A-601 - DOOR SCHEDULE.pdf PDF
Attachment117_DLA_OPS_PH II_S-604 - COLUMN SCHEDULE.pdf PDF
Attachment125_DLA_OPS_PH II_089100 SPECIFICATIONS VOL1-OMIT Metal Wall Louvers.pdf PDF
Attachment 61_DLA OPS_PH II_CS101.pdf PDF
Attachment81_DLA_OPS_PH II_A-207 - ENLARGED ELEVATIONS.pdf PDF
Attachment 68_DLA_OPS_PH II_A-113 - SECOND FLOOR PLAN - AREA A2.pdf PDF
Attachment 72_DLA_OPS_PH II_A-118 - THIRD FLOOR PLAN - AREA D3.pdf PDF
Attachment123_DLA_OPS_PH II_084400 SPECIFICATIONS VOL1-Para1.5.6.pdf PDF
Attachment75_DLA_OPS_PH II_A-121 - FIFTH FLOOR PLAN - AREA A5.pdf PDF
Attachment113_DLA_OPS_PH II_S-312 - FRAMING SECTIONS.pdf PDF
Attachment120_DLA_OPS_PH II_T-704 - VOICE AND DATA BACKBONE DIAGRAM.pdf PDF
Attachment115_DLA_OPS_PH II_S-503 - TYPICAL DETAILS.pdf PDF
Attachment107_DLA_OPS_PH II_S-131 - STAIRWELL FRAMING PLANS - AREA A AND AREA G.pdf PDF
Attachment92_DLA_OPS_PH II_A-603 - DOOR SCHEDULE AND DETAILS.pdf PDF
Attachment101_DLA_OPS_PH II_S-101 - DRILLED PIER AND PIER CAP PLAN - AREA A.pdf PDF
Attachment79_DLA_OPS_PH II_A-205 - ENLARGED ELEVATIONS.pdf PDF
Attachment128_DLA_OPS_PH II_316329 SPECIFICATIONS VOL2-Part 2.3.2.pdf PDF
Attachment104_DLA_OPS_PH II_S-115 - ROOF FRAMING PLAN - AREA C.pdf PDF
Attachment 64_DLA OPS_PH II_V-103.pdf PDF
Attachment112_DLA_OPS_PH II_S-304 - FOUNDATION SECTIONS.pdf PDF
Show 40 more

Latest 50 of 77 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DAVID P. ISBELL A

I

N I

G

RI

V

FOHTLAE

W

N O

M M

O C

No.

ARCH TI ECT

US Army Corps of Engineers ®

SHEET OF

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

1909 CYPRESS AVENUE

VIRGINIA BEACH, VA

23451

(757) 417 - 0140

C O

N T

R A

C T

N O

W

-1

-D

-0

10 JANUARY 2020

737345

A-702

F

IN

IS

H

S C

H E

D U

L E

D E

F E

N S

E

S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D

D S

C R

R

IC

H

M O

N D

V

IR

G

IN

IA

N O

R F

O L K

D

IS

T R

IC

T

F

R O

N T

S T

N

O R

F O

L K

V

A

W A

L L E

R T

O D

D

S A

D L E

R

A W

O O

L P

E R

T C

O M

P A

N Y

C

Y P

R E

S S

A V

E N

U E

V

IR

G

IN

IA

B

E A

C H

V

A

D S

R

F A

H

D S

R

D P

I

J

A N

U A

R Y

D L A

O P

E R

A T

IO

N

S C

E N

T E

R

P H

-2

D E

F E

N S

E L

O G

IS

T

IC

S

A G

E N

C Y

A

V

IA

T

IO

N D

S C

R

DLA OPS FINISH SCHEDULE A-702

ROOM

NUMBER

ROOM NAME FLOOR FINISH BASE FINISH WALL MATERIAL WALL FINISH

CEILING

MATERIAL

CEILING FINISH NOTES

163A STORAGE CLOSET LCT1 RB2 GWB PNT1 EXP PNT2

163B STORAGE CLOSET LCT1 RB2 GWB PNT1 EXP PNT2

164 CONFERENCE ROOM CPT1 RB1 GWB PNT1 SAPC SAPC1

165 CONFERENCE ROOM CPT1 RB1 GWB PNT1 SAPC SAPC1

166 OFFICE CUBICLES CPT1 RB1 GWB PNT1 GWB/ SAPC PNT2, SAPC2, SAPC3

167 TEAMING ROOM CPT1 RB1 GWB PNT1 SAPC SAPC1

168 TEAMING ROOM CPT1 RB1 GWB PNT1 SAPC SAPC1

169 CONFERENCE ROOM CPT1 RB1 GWB PNT1 SAPC SAPC1

170 OFFICE CPT1 RB1 GWB PNT1 SAPC SAPC1

171 OFFICE CPT1 RB1 GWB PNT1 SAPC SAPC1

172 TRAINING ROOM LCT1 RB2 GWB PNT1 SAPC SAPC1

173 TRAINING ROOM LCT1 RB2 GWB PNT1 SAPC SAPC1

174 COPY ROOM LCT1 RB2 GWB PNT1 SAPC SAPC1

175 PANTRY LCT1 RB2 GWB PNT1 SAPC SAPC1

176 OFFICE CUBICLES CPT1 RB1 GWB PNT1 GWB/ SAPC PNT2, SAPC2, SAPC3

177 CORRIDOR SC1 RB2 GWB PNT1 GWB PNT2

178 RECEIVING SC1 RB2 GWB PNT1 GWB PNT2

179 ELECTRICAL ROOM SC1 RB2 GWB PNT1 GWB PNT2

180 MECHANICAL ROOM SC1 RB2 GWB PNT1 GWB PNT2

181 OFFICE SC1 RB2 GWB PNT1 PNT2

182 RECYCLE ROOM PC1 RB2 GWB PNT1 SAPC SAPC1

DLA OPS FINISH SCHEDULE A-702

ROOM

NUMBER

ROOM NAME FLOOR FINISH BASE FINISH WALL MATERIAL WALL FINISH

CEILING

MATERIAL

CEILING FINISH NOTES

1A STAIR 1A RT1/T-R1 RB2 CMU PNT1 EXP PNT9

1B STAIR RT1/T-R1 RB2 CMU PNT1 EXP PNT9

1C STAIR RT1/T-R1 RB2 CMU PNT1 EXP PNT9

2A STAIR RT1/T-R1 RB2 CMU PNT1 EXP PNT9

2B STAIR RT1/T-R1 RB2 CMU PNT1 EXP PNT9

2C STAIR RT1/T-R1 RB2 CMU PNT1 SAPC SAPC1

3A STAIR RT1/T-R1 RB2 CMU PNT1 EXP PNT9

3B STAIR RT1/T-R1 RB2 CMU PNT1 EXP PNT9

4A STAIR RT1/T-R1 RB2 CMU PNT1 EXP PNT9

4B STAIR RT1/T-R1 RB2 CMU PNT1 EXP PNT9

5A STAIR RT1/T-R1 RB2 CMU PNT1 EXP PNT9

5B STAIR RT1/T-R1 RB2 CMU PNT1 EXP PNT9

6A STAIR RT1/T-R1 RB2 CMU PNT1 SAPC SAPC1

101 VESTIBULE EM1 RB1 STR FR/ BR VEN/ GWB PNT1 GWB/ EXP PNT2

102 LOBBY LVT1 RB2 GWB PNT1, WWC1 EXP PNT8 9,16

103 STOR LCT1 RB2 GWB PNT1 GWB PNT2

104 OFFICE CUBICLES CPT1 RB1 GWB PNT1 GWB/ SAPC PNT2, SAPC2, SAPC3

105 CORRIDOR LVT1 RB2 GWB PNT4 GWB/ SAPC PNT2, SAPC2 10

106 ELEVATOR LOBBY LVT1 RB2 GWB PNT4 GWB/ MPC PNT2, SAPC2, MPC1 10

107 OFFICE CUBICLES CPT1 RB1 GWB PNT1 GWB/ SAPC PNT2, SAPC2, SAPC3

108 STORAGE CLOSET LCT1 RB2 GWB PNT1 GWB PNT2

109 STORAGE CLOSET LCT1 RB2 GWB PNT1 GWB PNT2

110 PANTRY LCT1 RB2 GWB PNT1 SAPC SAPC1 1

111 COPY ROOM LCT1 RB2 GWB PNT1 SAPC SAPC1 2

112 CORRIDOR CPT1 RB1 GWB PNT4 GWB/ SAPC PNT2, SAPC1 10

113 CONFERENCE ROOM CPT1 RB1 GWB PNT1 GWB/ SAPC PNT2, SAPC1

114 CONFERENCE ROOM CPT1 RB1 GWB PNT1 GWB/ SAPC PNT2, SAPC1

115 OFFICE CPT1 RB1 GWB PNT1 SAPC SAPC1

116 OFFICE CPT1 RB1 GWB PNT1 SAPC SAPC1

117 WOMENS PT2 PT1 GWB PT1, PNT1 GWB/ SAPC PNT2, SAPC1

118 MENS PT2 PT1 GWB PT1, PNT1 GWB/ SAPC PNT2, SAPC1

119 JANITORS CLOSET SC1 FRP1 GWB FRP1, PNT1 GWB PNT2

120 CORRIDOR CPT1 RB1 GWB PNT4 SAPC SAPC2 10

121 TELECOM SDT1 RB2 GWB PNT1 EXP PNT2

122 ELEC ROOM LCT1 RB2 GWB PNT1 EXP PNT2

123 SECURITY LCT1 RB2 GWB PNT1 SAPC SAPC1

124 TRAINING ROOM CPT1 RB1 GWB PNT1 SAPC SAPC1

125 TEAMING ROOM CPT1 RB1 GWB PNT1 SAPC SAPC1

126 FILE ROOM LCT1 RB2 GWB PNT1 SAPC SAPC1

127 OFFICE CPT1 RB1 GWB PNT1 SAPC SAPC1

128 OFFICE CPT1 RB1 GWB PNT1 SAPC SAPC1

129 RECEPTION CPT1 RB1 GWB PNT1 SAPC SAPC1

130 OFFICE CPT1 RB1 GWB PNT1 SAPC SAPC1

131 OFFICE CPT1 RB1 GWB PNT1 SAPC SAPC1

132 CORRIDOR CPT1 RB1 GWB PNT4 GWB/ SAPC PNT2, SAPC2 10

133 STORAGE LCT1 RB2 GWB PNT1 GWB PNT2

134 COFFEE KIOSK PT2 PT1, RB2 GWB PT1, PNT1 GWB/ SAPC PNT2, SAPC1 1,11

135 ELEC ROOM LCT1 RB2 GWB PNT1 EXP PNT2

136 TELECOM SDT1 RB2 GWB PNT1 GWB PNT2

137 CORRIDOR LVT1 RB2 GWB PNT4 GWB/SAPC PNT2, SAPC1 10

138 WOMENS PT2 PT1 GWB PT1, PNT1 GWB/ SAPC PNT2, SAPC1 3,4,5,6

139 MENS PT2 PT1 GWB PT1, PNT1 GWB/ SAPC PNT2, SAPC1 3,4,5,6

140 JANITORS CLOSET SC1 FRP1 GWB FRP1, PNT1 GWB PNT2 7

141 CORRIDOR LVT1 RB2 GWB PNT4 GWB/ SAPC PNT2, SAPC2 10

142 CORRIDOR LVT1 RB2 GWB PNT1 GWB/SAPC PNT2, SAPC2

143 SUNDRIES SHOP LCT1 RB2 GWB PNT1 SAPC SAPC1 12,13

144 SUNDRIES STORAGE LCT1 RB2 GWB PNT1 EXP PNT2

145 CONFERENCE ROOM CPT1 RB1 GWB PNT1 SAPC SAPC1

146 OFFICE CUBICLES CPT1 RB1 GWB PNT1 GWB/SAPC PNT2, SAPC2, SAPC3

147 OFFICE CUBICLES CPT1 RB1 GWB PNT1 GWB/ SAPC PNT2, SAPC2, SAPC3

148 LOBBY LVT1 RB2 CW/ GWB PNT1 GWB/ SAPC SAPC2, PNT2

149 VESTIBULE EM1 RB1 CW/ GWB PNT1 SAPC PNT2

150 METROLOGY LAB PC1 RB2 GWB PNT1 SAPC SAPC1 16

151 MYLAR ROOM PC1 RB2 GWB PNT1 SAPC SAPC1 16

152 OFFICE CUBICLES CPT1 RB1 GWB PNT1 GWB/ SAPC PNT2, SAPC2, SAPC3

153 OFFICE CPT1 RB1 GWB PNT1 SAPC SAPC1

154 OFFICE CPT1 RB1 GWB PNT1 SAPC SAPC1

155 SUPPLY ROOM LCT1 RB2 GWB PNT1 SAPC SAPC1 14

156 TELECOMM SDT1 RB2 GWB PNT1 SAPC SAPC1

157 CORRIDOR CPT1 RB1 GWB PNT4 SAPC SAPC2 10

158A STORAGE CLOSET LCT1 RB2 GWB PNT1 EXP PNT2

158B ELEC ROOM LCT1 RB2 GWB PNT1 EXP PNT2

159 COPY ROOM LCT1 RB2 GWB PNT1 SAPC SAPC1 2

160 PANTRY LCT1 RB2 GWB PNT1 SAPC SAPC1 1

161 TEAMING ROOM CPT1 RB1 GWB PNT1 SAPC SAPC1

162 OFFICE CUBICLES CPT1 RB1 GWB PNT1 GWB/ SAPC PNT2, SAPC2, SAPC3

FINISH SCHEDULE NOTES

1 PROVIDE COUNTER, SS2, WITH CABINETS, PLAM2, IN PANTRY ROOMS AND COFFEE

KIOSK.

2 PROVIDE COUNTER, PLAM1, WITH CABINETS, PLAM2 IN COPY ROOMS.

3 IN TOILET ROOMS, PROVIDE WALL TILE TO 7'-0" AFF. INSTALL THE 24" OF THE TILE ON

THE HORIZONTAL.

4 PROVIDE, TP1, FOR THE TOILET PARTITIONS IN THE TOILET ROOMS.

5 USE GROUT, G1, WITH THE FLOOR TILES AND GROUT, G2, WITH THE WALL TILES IN

TOILET ROOMS.

6 PROVIDE COUNTER, SS1, IN TOILET ROOMS.

7 PROVIDE, FRP1, ON THE WALLS ADJACENT TO THE FLOOR DRAIN IN THIS LOCATION.

8 PROVIDE , PLAM3, FOR THE INTERIOR WALLS IN THE ELEVATOR CAB.

9 PROVIDE, WWC1, ON EAST WALL IN THIS LOCATION.

10 PAINT ACCENT COLOR ON ALL WALLS IN THIS LOCATION.

11 PAINT UNDERSIDE OF COUNTER AT COFFEE KIOSK PT4.

12 PROVIDE, FRP1, IN THE BACK STORAGE AREA.

13 THE FURNITURE ITEMS IN THIS LOCATION ARE OFOI.

14 SHELVING: SEE TYPICAL DETAIL ON A-526.

15 SEE DETAIL A9 ON SHEET A-422 FOR CLOSET SHELF AND ROD DETAIL.

16 PROVIDE, WS2, IN THIS LOCATION.

GENERAL FINISH NOTES

A. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE

FIELD.

B. PROVIDE CORNER GUARDS, CG1, AT ALL EXPOSED CORNERS.

CORNER GUARDS SHALL BE FROM BEGIN FROM TOP OF THE

BASE AND END AT 6'-0" AFF.

C. PAINT ALL INTERIOR METAL DOOR FRAMES ,PNT3.

D. PROVIDE, WS1, AT ALL WINDOWS WITHIN CONFERENCE

ROOMS.

E. PROVIDE, WS2, WITHIN OFFICE AND OPEN OFFICES.

F. PROVIDE, SS3, AT WINDOW SILLS.

G. RUBBER FLOOR TRANSITIONS SHALL BE ROPPE 114 LUNAR

DUST.

H. METAL TRANSITIONS SHALL BE ANODIZED ALUMINUM.

I. PROVIDE, WS2, ON EXTERIOR WINDOWS.

A

M E

N D

M E

N T

N O

-2 -2

A

M E

N D

M E

N T

N O

-0 -2

File details come from the government source that posted it. Updated .