This pre-solicitation notice provides information about an upcoming Request for Proposal for construction services related to the DLA Aviation Operations Center, Phase II project at Defense Supply Center Richmond in Virginia. The U.S. Army Corps of Engineers-Norfolk District intends to issue an RFP to construct a 281,075 square foot, multi-story office building to accommodate 1,622 employees. The project requirements include open and individual administrative offices, support spaces, building systems, site improvements, and supporting facilities. The contract will utilize conventional design and construction methods and have a period of performance of 1020 calendar days. The solicitation will be issued on or about May 27, 2020 on beta.sam.gov as a full and open competition with award as a firm-fixed-price contract. The estimated value is between $25-100 million. Evaluation will consider past performance, project approach, small business participation, and price.
View the file
Other files
Show 40 more
Latest 50 of 77 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DLA OPS CENTER PHASE 2 W91236-17-D-002
DEFENSE SUPPLY CENTER RICHMOND (DSCR), RICHMOND, VA
SECTION 08 71 00
DOOR HARDWARE
02/16
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM E283 (2004; R 2012) Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen
BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)
ANSI/BHMA A156.1 (2016) Butts and Hinges
ANSI/BHMA A156.10 (2017) Power Operated Pedestrian Doors
ANSI/BHMA A156.13 (2017) Mortise Locks & Latches Series 1000
ANSI/BHMA A156.15 (2015) Release Devices Closer Holder, Electromagnetic and Electromechanical
ANSI/BHMA A156.16 (2018) Auxiliary Hardware
ANSI/BHMA A156.17 (2014) Self Closing Hinges & Pivots
ANSI/BHMA A156.18 (2016) Materials and Finishes
ANSI/BHMA A156.19 (2013) Power Assist & Low Energy Power Operated Doors
ANSI/BHMA A156.21 (2014) Thresholds
ANSI/BHMA A156.22 (2017) Door Gasketing and Edge Seal Systems
ANSI/BHMA A156.23 (2010) Electromagnetic Locks
ANSI/BHMA A156.26 (2012) Continuous Hinges
ANSI/BHMA A156.29 (2012) Exit Locks, Exit Alarms, Alarms for Exit Devices
ANSI/BHMA A156.3 (2014) Exit Devices
ANSI/BHMA A156.36 (2010) Auxiliary Locks
ANSI/BHMA A156.4 (2013) Door Controls - Closers
SECTION 08 71 00 Page 1
ANSI/BHMA A156.5 (2014) Cylinder and Input Devices for Locks
ANSI/BHMA A156.6 (2015) Architectural Door Trim
ANSI/BHMA A156.7 (2016) Template Hinge Dimensions
ANSI/BHMA A156.8 (2015) Door Controls - Overhead Stops and Holders
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 101 (2018; TIA 18-1; TIA 18-2; TIA 18-3) Life Safety Code
NFPA 252 (2017) Standard Methods of Fire Tests of Door Assemblies
NFPA 70 (2017; ERTA 1-2 2017; TIA 17-1; TIA 17-2;
TIA 17-3; TIA 17-4; TIA 17-5; TIA 17-6;
TIA 17-7; TIA 17-8; TIA 17-9; TIA 17-10;
TIA 17-11; TIA 17-12; TIA 17-13; TIA
17-14; TIA 17-15; TIA 17-16; TIA 17-17 )
National Electrical Code
NFPA 72 (2016; Errata 1 2018) National Fire Alarm and Signaling Code
NFPA 80 (2016; TIA 16-1) Standard for Fire Doors and Other Opening Protectives
STEEL DOOR INSTITUTE (SDI/DOOR)
SDI/DOOR A250.8 (2003; R2008) Recommended Specifications for Standard Steel Doors and Frames
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
UNDERWRITERS LABORATORIES (UL)
UL Bld Mat Dir (updated continuously online) Building Materials Directory
1.2 SUBMITTALS
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance with Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
SECTION 08 71 00 Page 2
Hardware Schedule;
Keying System;
SD-03 Product Data
Hardware Items;
SD-08 Manufacturer's Instructions
Installation
SD-10 Operation and Maintenance Data
Hardware Schedule Items, Data Package 1;
SD-11 Closeout Submittals
Key Bitting
1.3 SHOP DRAWINGS
Submit manufacturer's detail drawings indicating all hardware assembly components and interface with adjacent construction. Indicate power components and wiring coordination for electrified hardware. Base shop drawings on verified field measurements and include verification of existing conditions.
1.4 PRODUCT DATA
Indicate fire-ratings at applicable components. Provide documentation of ABA/ADA accessibility compliance of applicable components, as required by 36 CFR 1191 Appendix D - Technical.
1.5 HARDWARE SCHEDULE
Prepare and submit hardware schedule in the following form:
Hardware Item
Quantity Size Reference Publi-cation Type No.
Finish Mfr Name and Catalog No.
Key Control Symbols
UL
Mark (If fire-rated and listed)
BHMA
Finish Desig-nation
In addition, submit hardware schedule data package 1 in accordance with Section 01 78 23 OPERATION AND MAINTENANCE DATA.
1.6 KEY BITTING CHART REQUIREMENTS
1.6.1 Requirements
Submit key bitting charts to the Contracting Officer prior to completion of the work. Include:
a. Complete listing of all keys (e.g. AA1 and AA2).
SECTION 08 71 00 Page 3
b. Complete listing of all key cuts (AA1-123456, AA2-123458).
c. Tabulation showing which key fits which door.
d. Copy of floor plan showing doors and door numbers.
e. Listing of 20 percent more key cuts than are presently required in each master system.
1.7 QUALITY ASSURANCE
1.7.1 Hardware Manufacturers and Modifications
Provide, as far as feasible, locks, hinges, pivots, and closers of one lock, hinge, pivot, or closer manufacturer's make. Modify hardware as necessary to provide features indicated or specified.
1.7.2 Key Shop Drawings Coordination Meeting
Prior to the submission of the key shop drawing, the Contracting Officer, Contractor, Door Hardware Subcontractor, using Activity and Base Locksmith must meet to discuss and coordinate key requirements for the facility.
1.8 DELIVERY, STORAGE, AND HANDLING
Deliver hardware in original individual containers, complete with necessary appurtenances including fasteners and instructions. Mark each individual container with item number as shown on hardware schedule.
Deliver permanent keys and removable cores to the Contracting Officer, either directly or by certified mail. Deliver construction master keys with the locks.
PART 2 PRODUCTS
2.1 TEMPLATE HARDWARE
Hardware applied to metal or to prefinished doors must be manufactured using a template. Provide templates to door and frame manufacturers in accordance with ANSI/BHMA A156.7 for template hinges. Coordinate hardware items to prevent interference with other hardware.
2.2 HARDWARE FOR FIRE DOORS AND EXIT DOORS
Provide all hardware necessary to meet the requirements of NFPA 72 for door alarms, NFPA 80 for fire doors, NFPA 101 for exit doors, NFPA 252 for fire tests of door assemblies, ABA/ADA accessibility requirements, and all other requirements indicated, even if such hardware is not specifically mentioned in paragraph HARDWARE SCHEDULE. Provide Underwriters Laboratories, Inc. labels for such hardware in accordance with UL Bld Mat Dir or equivalent labels in accordance with another testing laboratory approved in writing by the Contracting Officer.
2.3 HARDWARE ITEMS
Clearly and permanently mark with the manufacturer's name or trademark, hinges, pivots, locks, latches, exit devices, bolts and closers where the identifying mark is visible after the item is installed. For closers with covers, the name or trademark may be beneath the cover. Coordinate
SECTION 08 71 00 Page 4 electrified door hardware components with corresponding components specified in Division 28 ELECTRONIC SECURITY SYSTEMS (ESS).
2.3.1 Hinges
Provide in accordance with ANSI/BHMA A156.1 . Provide hinges that are 4-1/2 by 4-1/2 inch unless otherwise indicated. Construct loose pin hinges for interior doors and reverse-bevel exterior doors so that pins are non-removable when door is closed. Other anti-friction bearing hinges may be provided in lieu of ball bearing hinges.
2.3.2 Continuous Hinges
Where continuous hinges are required, provide in accordance with
ANSI/BHMA A156.26 .
2.3.3 Pivots
Provide in accordance with ANSI/BHMA A156.17 .
2.3.4 Spring Hinges
Provide in accordance with ANSI/BHMA A156.17 .
2.3.5 Locks and Latches
2.3.5.1 Mortise Locks and Latches
Provide in accordance with ANSI/BHMA A156.13 , Series 1000, Operational Grade 1, Security Grade 2. Provide mortise locks with escutcheons not less than 7 by 2-1/4 inch with a bushing at least 1/4 inch long. Cut escutcheons to fit cylinders and provide trim items with straight, beveled, or smoothly rounded sides, corners, and edges. Provide knobs and roses of mortise locks with screwless shanks and no exposed screws.
2.3.5.2 Auxiliary Locks
Provide in accordance with ANSI/BHMA A156.36 , Grade 1.
2.3.6 Exit Devices
Provide in accordance with ANSI/BHMA A156.3 , Grade 1. Provide adjustable strikes for rim type and vertical rod devices. Provide open back strikes for pairs of doors with mortise and vertical rod devices. Provide touch bars in lieu of conventional crossbars and arms.
2.3.7 Exit Locks With Alarm
Provide in accordance with ANSI/BHMA A156.3 and ANSI/BHMA A156.29 , Type E0431 (with full width horizontal actuating bar) for single doors; Type E0431 (with actuating bar) or E0471 (with actuating bar and top and bottom bolts, both leaves active) for pairs of doors, unless otherwise specified.
Provide terminals for connection to remote indicating panel. Provide door alarms integrated with the fire alarm system in accordance with
NFPA 72 .
2.3.8 Cylinders and Cores
Provide cylinders and cores for new locks, including locks provided under
SECTION 08 71 00 Page 5 other sections of this specification. Provide cylinders and cores with seven pin tumblers. Provide cylinders from the products of one manufacturer, and provide cores from the products of one manufacturer.
Rim cylinders, mortise cylinders, and knobs of bored locksets have interchangeable cores which are removable by special control keys. Stamp each interchangeable core with a key control symbol in a concealed place on the core.
2.3.9 Electrified Hardware
Comply with the requirements of NFPA 70 for wiring of electrified hardware.
2.3.9.1 Power Operated Pedestrian Door Hardware
Provide in accordance with ANSI/BHMA A156.10 , Grade 1.
2.3.9.2 Release Devices
In accordance with ANSI/BHMA A156.15 , Grade 1.
2.3.9.3 Power Assist and Low Energy Power Operated Doors
Provide in accordance with ANSI/BHMA A156.19 , Grade 1.
2.3.9.4 Electromagnetic Locks
Provide in accordance with ANSI/BHMA A156.23 , Grade 1. Provide electromagnetic locks that do not contain any moving parts and depend solely upon electromagnetism to secure a portal by generating at least 1200 pounds of holding force. The lock must interface with the local processors without external, internal or functional alteration of the local processor. The electromagnetic lock must incorporate an end of line resistor to facilitate line supervision by the system. Provide metal-oxide resistors (MOVs) to protect controllers from reverse current surges, if not incorporated into the electromagnetic lock or local controller.
2.3.10 Keying System
Provide sub-master keying system for the building, and keyed to the existing Best removable-core master and grand master keying systems. Key equipment spaces and mechanical rooms separately from the building systems, and keyed alike to the existing Best master and grand master systems for these doors..
The Contractor will deliver to the Government the permanent cylinders with cores and keys for mortise locksets, auxiliary locks, and exit devices.
Furnish cylinders as manufactured by Best Lock Corp. Notify the Contracting officer 90 days prior to the required delivery of the cylinders. Provide temporary cores and keys for the Contractor's use during construction, and for testing the locksets
2.3.11 Lock Trim
Provide cast, forged, or heavy wrought construction and commercial plain design for lock trim.
SECTION 08 71 00 Page 6
2.3.11.1 Lever Handles
Provide lever handles in lieu of knobs where indicated in paragraph entitles "Hardware Schedule". Provide in accordance with ANSI/BHMA A156.3 for mortise locks of lever handles for exit devices. Provide lever handle locks with a breakaway feature (such as a weakened spindle or a shear key) to prevent irreparable damage to the lock when force in excess of that specified in ANSI/BHMA A156.13 is applied to the lever handle. Provide lever handles return to within 1/2 inch of the door face.
2.3.12 Keys
Furnish seven change keys for each interchangeable core, furnish two control keys, six maters keys, and six construction master keys. Furnish a minimum of four keys for each permanent core. Furnish a quantity of key blanks equal to 20 percent of the total number of change keys. Stamp each key with appropriate key control symbol and "U.S. property - do not duplicate." Do not place room numbers on keys.
2.3.13 Door Bolts
Provide in accordance with ANSI/BHMA A156.16 . Provide dustproof strikes for bottom bolts, except at doors having metal thresholds. Provide automatic latching flush bolts in accordance with ANSI/BHMA A156.3 , Type 25.
2.3.14 Closers
Provide in accordance with ANSI/BHMA A156.4 , Series C02000, Grade 1, with PT 4C. Provide with brackets, arms, mounting devices, fasteners, full size covers, except at storefront mounting, pivots, cement cases, and other features necessary for the particular application. Size closers in accordance with manufacturer's printed recommendations, or provide multi-size closers, Sizes 1 through 6, and list sizes in the Hardware Schedule. Provide manufacturer's 10 year warranty.
2.3.14.1 Identification Marking
Engrave each closer with manufacturer's name or trademark, date of manufacture, and manufacturer's size designation in locations that will be visible after installation.
2.3.15 Overhead Holders
Provide in accordance with ANSI/BHMA A156.8 .
2.3.16 Door Protection Plates
Provide in accordance with ANSI/BHMA A156.6 .
2.3.16.1 Sizes of Kick Plates
2 inch less than door width for single doors; 1 inch less than door width for pairs of doors. Provide 10 inch kick plates for flush doors. Provide a minimum 36 inch armor plates for flush doors , except 16 inch high armor plates on fire doors. Provide 6 inch mop plates.
SECTION 08 71 00 Page 7
2.3.16.2 Edge Guards
Stainless steel, of same height as armor plates. Apply to hinge stile .
2.3.17 Door Stops and Silencers
Provide in accordance with ANSI/BHMA A156.16 . Silencers Type L03011.
Provide three silencers for each single door, two for each pair.
2.3.18 Thresholds
Provide in accordance with ANSI/BHMA A156.21 . Use J35100, with vinyl or silicone rubber insert in face of stop, for exterior doors opening out, unless specified otherwise.
2.3.19 Weatherstripping Gasketing
Provide in accordance with ANSI/BHMA A156.22 . Provide the type and function designation where specified in paragraph HARDWARE SCHEDULE.
Provide a set to include head and jamb seals, sweep strips, and, for pairs of doors, astragals. Air leakage of weatherstripped doors not to exceed
1.25 cubic feet per minute of air per square foot of door area when tested in accordance with ASTM E283. Provide weatherstripping with one of the following:
2.3.19.1 Extruded Aluminum Retainers
Extruded aluminum retainers not less than 0.050 inch wall thickness with vinyl, neoprene, silicone rubber, or polyurethane inserts. Provide clear (natural) or bronze anodized aluminum.
2.3.19.2 Interlocking Type
Zinc or bronze not less than 0.018 inch thick.
2.3.19.3 Spring Tension Type
Spring bronze or stainless steel not less than 0.008 inch thick.
2.3.20 Rain Drips
Provide in accordance with ANSI/BHMA A156.22 . Provide extruded aluminum rain drips, not less than 0.08 inch thick, clear anodized finish.
2.3.21 Special Tools
Provide special tools, such as spanner and socket wrenches and dogging keys, as required to service and adjust hardware items.
2.4 FASTENERS
Provide fasteners of type, quality, size, and quantity appropriate to the specific application. Fastener finish to match hardware. Provide stainless steel or nonferrous metal fasteners in locations exposed to weather. Verify metals in contact with one another are compatible and will avoid galvanic corrosion when exposed to weather.
SECTION 08 71 00 Page 8
2.5 FINISHES
Provide in accordance with ANSI/BHMA A156.18 . Provide hardware in BHMA 630 finish (satin stainless steel), unless specified otherwise. Provide items not manufactured in stainless steel in BHMA 626 finish (satin chromium plated) over brass or bronze, except aluminum paint or prime coat finish for surface door closers, and except BHMA 652 finish (satin chromium plated) BHMA 600 finish (primed for painting) for steel hinges.
Provide hinges for exterior doors in stainless steel with BHMA 630 finish or chromium plated brass or bronze with BHMA 626 finish. Furnish exit devices in BHMA 626 finish in lieu of BHMA 630 finish except where BHMA 630 is specified under paragraph HARDWARE SETS. Match exposed parts of concealed closers to lock and door trim. Match hardware finish for aluminum doors to the doors.
2.6 KEY CABINET AND CONTROL SYSTEM
Provide in accordance with ANSI/BHMA A156.5 , Type required to yield a capacity (number of hooks) 50 percent greater than the number of key changes used for door locks.
PART 3 EXECUTION
3.1 INSTALLATION
Provide hardware in accordance with manufacturers' printed installation instructions. Fasten hardware to wood surfaces with full-threaded wood screws or sheet metal screws. Provide machine screws set in expansion shields for fastening hardware to solid concrete and masonry surfaces.
Provide toggle bolts where required for fastening to hollow core construction. Provide through bolts where necessary for satisfactory installation.
3.1.1 Weatherstripping Installation
Provide full contact, weathertight seals that allow operation of doors without binding the weatherstripping.
3.1.1.1 Stop Applied Weatherstripping
Fasten in place with color matched sheet metal screws not more than 9 inch on center after doors and frames have been finish painted.
3.1.1.2 Interlocking Type Weatherstripping
Provide interlocking, self adjusting type on heads and jambs and flexible hook type at sills. Nail weatherstripping to door 1 inch on center and to heads and jambs at 4 inch on center.
3.1.1.3 Spring Tension Type Weatherstripping
Provide spring tension type on heads and jambs. Provide bronze nails with bronze. Provide stainless steel nails with stainless steel. Space nails not more than 1-1/2 inch on center.
3.1.2 Soundproofing Installation
Provide as specified for stop applied weatherstripping.
SECTION 08 71 00 Page 9
3.1.3 Threshold Installation
Extend thresholds the full width of the opening and notch end for jamb stops. Set thresholds in a full bed of sealant and anchor to floor with cadmium-plated, countersunk, steel screws in expansion sleeves. For aluminum thresholds placed on top of concrete surfaces, coat the underside surfaces that are in contact with the concrete with fluid applied waterproofing as a separation measure prior to placement.
3.2 FIRE DOORS AND EXIT DOORS
Provide hardware in accordance with NFPA 72 for door alarms, NFPA 80 for fire doors, NFPA 101 for exit doors, and NFPA 252 for fire tests of door assemblies.
3.3 HARDWARE LOCATIONS
Provide in accordance with SDI/DOOR A250.8 , unless indicated or specified otherwise.
a. Kick and Armor Plates: Push side of single-acting doors. Both sides of double-acting doors.
b. Mop Plates: Bottom flush with bottom of door.
3.4 KEY CABINET AND CONTROL SYSTEM
Locate where directed by Contracting Officer. Tag one set of file keys and one set of duplicate keys. Place other keys in appropriately marked envelopes, or tag each key. Provide complete instructions for setup and use of key control system. On tags and envelopes, indicate door and room numbers or master or grand master key.
3.5 FIELD QUALITY CONTROL
After installation, protect hardware from paint, stains, blemishes, and other damage until acceptance of work. Submit notice of testing 15 days before scheduled, so that testing can be witnessed by the Contracting Officer. Adjust hinges, locks, latches, bolts, holders, closers, and other items to operate properly. Demonstrate that permanent keys operate respective locks, and give keys to the Contracting Officer. Correct, repair, and finish, errors in cutting and fitting and damage to adjoining work.
3.6 HARDWARE SETS
See next pages for 3.6 HARDWARE SETS.
-- End of Section --
SECTION 08 71 00 Page 10
Section 08 71 00 Page 1
3.6 HARDWARE SETS
Provide hardware for aluminum doors under this section. Deliver Hardware templates and hardware, except field applied hardware, to the aluminum door and frame manufacturer for use in fabricating doors and frames.
1. MK - McKinney
2. PE - Pemko
3. RO - Rockwood
4. YA - Yale
5. OT - OTHER
6. HS - HES
7. RF - Rixson
8. NO - Norton
9. SU - Securitron
Hardware Sets
Set: 1.0
Doors: 101B, 1100A.1, 1124A, 148
2 Continuous Hinge (A31031B) CFM (height)SLF-HD1 PT PE
1 Removable Mullion (Type 22) KRM200 - DOOR HEIGHT 600 YA
1 Exit Device (exit only) 7100 B P EO 630 YA
1 Exit Device (nightlatch) 7100 B P 121NL K645xCT7SL 630 YA
2 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
1 SFIC Cylinder Housing* Rim/ Mortise as Required 626 OT
2 Pull (J402) RM201 Mtg-Type 12XHD US32D RO
2 Overhead Stop (C01541) 6ADJ-X36 630 RF
2 Door Operator 6010 / 6020 (TO SUIT) 689 NO
1 Threshold (J36100) 2009APK PE
1 Rain Guard (R0Y976) 346C PE
2 Sweep (R3D534) 345AV PE
2 Electric Power Transfer* EL-CEPT SU
2 Frame Harness QC-C1500P MK
2 Door Harness QC-C___ MK
2 Position Switch (E08)* DPS-M-BK SU
1 Power Supply* BPS-24-_ SU
Notes:
*Waiver may be required to comply with Trade Agreement Act.
o Perimeter/meeting stile seals by frame/door supplier.
o Card reader by security integrator.
o Electronic Operation: Outside, Card reader signals power supply to retract exit device latch allowing entry by door pull or automatic operator by wall switch. Key override. Inside, Free egress at all times by exit device with request to exit in panic bar or automatic operator by wall switch with request to exit switch in operator switch. In case of power loss, door remains locked and latched.
Set: 2.0
Doors: 101A, 1100A.2, 1124B
Section 08 71 00 Page 2
2 Continuous Hinge (A51031B) CFM (height)SLF-HD1 PE
1 Exit Device (Type 1, 03) 7100 121NL K645xCT7SL 630 YA
1 Exit Device (Type 1, 02) 7100 EO 630 YA
2 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
1 SFIC Cylinder Housing* Rim/ Mortise as Required 626 OT
2 Pull (J402) RM201 Mtg-Type 12XHD US32D RO
2 Surface Closer (C02021-Spg Stop) UNI3501 689 YA
1 Threshold (J36100) 2009APK PE
2 Sweep (R3D534) 345AV PE o Perimeter/meeting stile seals by frame/door supplier.
Set: 3.0
Doors: 102A
2 Exit Device (Type 1, 02) 7100 EO 630 YA
1 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
1 SFIC Cylinder Housing* Rim/ Mortise as Required 626 OT
2 Surface Closer (C02021-Spg Stop) UNI3501 689 YA
1 Threshold (J36100) 2009APK PE
1 Rain Guard (R0Y976) 346C PE
2 Sweep (R3D534) 345AV PE
Set: 4.0
Doors: S1C.1
6 Hinge (A5111) T4A3386 x USA US32D MK
1 Removable Mullion (Type 22) KRM200F - DOOR HEIGHT 600 YA
1 Exit Device (exit only) 7100F B EO 630 YA
1 Exit Device (storeroom) 7100F B P AU627F K645xCT7SL 630 YA
2 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
1 SFIC Cylinder Housing* Rim/ Mortise as Required 626 OT
2 Surface Closer (C02021-Spg Stop) UNI3501 689 YA
2 Kick Plate (J102) K1050 10" CSK US32D RO
1 Gasketing (R3E164) 303AS (HEAD/JAMBS) PE
2 Sweep (R3D534) 345AV PE
2 Astragal (R3E734) 29310CS PE
2 Electric Power Transfer* EL-CEPT SU
2 Frame Harness QC-C1500P MK
2 Door Harness QC-C___ MK richter Line richter Text Box S1A richter Cloud richter Line richter Rectangle richter Line richter Line richter Cloud richter Text Box
NOT USED
Section 08 71 00 Page 3 o Card reader by security integrator.
o Electronic Operation: Valid card or key retracts latchbolt. Request to exit shows authorized egress. Free egress at all times. In case of power loss, door remains locked and latched.
Set: 5.0
Doors: 1A, S1A
1 Exit Device (Type 1, 03) 7100 121NL K645xCT7SL 630 YA
1 Exit Device (Type 1, 02) 7100 EO 630 YA
3 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
1 SFIC Cylinder Housing* Rim/ Mortise as Required 626 OT
2 Pull (J402) RM201 Mtg-Type 12XHD US32D RO
2 Surface Closer (C02021-Spg Stop) UNI3501 689 YA
2 Kick Plate (J102) K1050 10" CSK US32D RO
1 Threshold (J36100) 2009APK PE
1 Rain Guard (R0Y976) 346C PE
1 Gasketing (R3E164) 303AS (HEAD/JAMBS) PE
2 Sweep (R3D534) 345AV PE
2 Astragal (R3E734) 29310CS PE
Set: 6.0
Doors: 1B, SIB
1 Removable Mullion (Type 22) KRM200F - DOOR HEIGHT 600 YA
1 Exit Device (exit only) 7100F EO 630 YA
1 Exit Device (storeroom) 7100F AU627F K645xCT7SL 630 YA
2 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
1 SFIC Cylinder Housing* Rim/ Mortise as Required 626 OT
2 Surface Closer (C02021-Spg Stop) UNI3501 689 YA
2 Kick Plate (J102) K1050 10" CSK US32D RO
1 Threshold (J36100) 2009APK PE
1 Rain Guard (R0Y976) 346C PE
1 Gasketing (R3E164) 303AS (HEAD/JAMBS) PE
2 Sweep (R3D534) 345AV PE
Set: 7.0
Doors:
Not Used.
richter Text Box , 2229 richter Cloud
Section 08 71 00 Page 4
Set: 8.0
Doors: 101C, 102B, 1100A.4, 201A, 201B, 2201A, 2201B, 301A, 301B, 401A, 401B, 501A, 501B
2 Push Pull (J505) RM251 Mtg-Type 12XHD US32D RO
2 Surface Closer (C02021-Spg Stop) UNI3501 689 YA
Set: 9.0
Doors: 101D, 1100A.3, 1124C, 149
2 Push Pull (J505) RM251 Mtg-Type 12XHD US32D RO
2 Overhead Stop (C01541) 6ADJ-X36 630 RF
2 Door Operator 6010 / 6020 (TO SUIT) 689 NO
2 Wave To Open Switch* 700 NO o Perimeter/meeting stile seals by frame/door supplier.
o Electronic operation: Outside, automatic operator by wall switch. Inside, Free egress at all times by push bar or automatic operator by wall switch.
Set: 10.0
Doors:
Not Used.
Set: 11.0
Doors: 176, S1C.2, 150B, 180B, 180C
3 Hinge (A8111) T4A3786 x USA US26D MK
1 Exit Device (Type 1, 14) 7100F AU628F 630 YA
1 Surface Closer (C02011 / C02021) R/ PR3501 (TO SUIT) 689 YA
1 Kick Plate (J102) K1050 10" CSK US32D RO
1 Door Stop (L02251 / L02121) 403/470 (TO SUIT) US26D RO
1 Adhesive Gasketing (R0Y154) S88BL PE
Set: 12.0
Doors: 104, 107, 1102A, 1102B, 1156, 141, 2208A, 2208B, 180A
6 Hinge (A8111) T4A3786 x USA US26D MK
2 Exit Device (classroom) 7170 LBR AU626F K645xCT7SL 630 YA
2 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
2 Surface Closer (C02011 / C02021) R/ PR3501 (TO SUIT) 689 YA
2 Kick Plate (J102) K1050 10" CSK US32D RO
2 Door Stop (L02251 / L02121) 403/470 (TO SUIT) US26D RO
2 Silencer (L03011) 608 RO
, 176, 2211A richter Cloud richter Line richter Rectangle richter Line richter Line richter Cloud richter Text Box
NOT USED
richter Line
Cloud
Section 08 71 00 Page 5
Set: 13.0
Doors: 1148
1 Exit Device (classroom) 7100 AU626F K645xCT7SL 630 YA
1 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
1 Surface Closer (C02011 / C02021) R/ PR3501 (TO SUIT) 689 YA
1 Kick Plate (J102) K1050 10" CSK US32D RO
3 Silencer (L03011) 608 RO
Set: 14.0
Doors: 142, S2A, S2B, S2C, S3A, S3B, S4A, S4B, S5A, S5B
2 Exit Device (passage) 6170F LBR AU628F 630 YA
2 Surface Closer (C02011 / C02021) R/ PR3501 (TO SUIT) 689 YA
2 Kick Plate (J102) K1050 10" CSK US32D RO
2 Door Stop (L02251 / L02121) 403/470 (TO SUIT) US26D RO
Set: 15.0
Doors: 150A
1 Dust Proof Strike (L04021)* 570 US26D RO
1 Automatic Flush Bolt (Type 27) 2848 / 2948 (TO SUIT) US32D RO
1 Fail Secure Lock (E01, E06) AUR 8891FL K625xCT7SL REX 626 YA
1 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
1 Coordinator (Type 21A) 2600 Series (Brackets To Suit) Black RO
2 Surface Closer (C02011 / C02021) R/ PR3501 (TO SUIT) 689 YA
2 Kick Plate (J102) K1050 10" CSK US32D RO
2 Door Stop (L02251 / L02121) 403/470 (TO SUIT) US26D RO
1 Adhesive Gasketing (R0Y154) S88BL PE
1 Astragal (R0Y634) 357SP PE
1 Electric Power Transfer* EL-CEPT SU
1 Frame Harness QC-C1500P MK
1 Door Harness QC-C___ MK o Card reader by security integrator.
richter Text Box , 177, 178A, 203, S1C.2
Section 08 71 00 Page 6 o Electronic Operation: Valid card unlocks outside lever or key retracts latchbolt. Request to exit shows authorized egress. Free egress at all times.
In case of power loss, door remains locked and latched.
Set: 16.0
Doors: 108, 109, 1114, 1115, 1120, 206, 207, 2224, 2225, 2230, 248, 249, 306, 307, 342, 343, 406, 407, 442, 443, 506, 507, 543, 544
6 Hinge (A8112) TA2714 x USA US26D MK
2 Manual Flush Bolt (L04251 / L04261) 555/ 557 (TO SUIT) US26D RO
1 Storeroom Lock (F07) AUR 8805FL K625xCT7SL 626 YA
1 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
2 Surf Overhead Stop (CO2541) 9-X36 630 RF
Set: 17.0
Doors: 1125A, 1128A
1 Automatic Flush Bolt (Type 27) 2848 / 2948 (TO SUIT) US32D RO
1 Storeroom Lock (F07) AUR 8805FL K625xCT7SL 626 YA
1 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
1 Coordinator (Type 21A) 2600 Series (Brackets To Suit) Black RO
2 Surface Closer (C02011 / C02021) R/ PR3501 (TO SUIT) 689 YA
2 Kick Plate (J102) K1050 10" CSK US32D RO
2 Door Stop (L02251 / L02121) 403/470 (TO SUIT) US26D RO
2 Adhesive Gasketing (R0Y154) S88BL PE
1 Astragal (R0Y634) 357SP PE
Set: 18.0
Doors: 1104, 1106, 1111, 119, 133, 140, 144, 155, 158A, 158B, 163A, 163B, 217, 220, 2215, 2220, 227, 235, 240, 314, 317, 330, 335, 417, 420, 430, 434, 513, 517, 531, 536
3 Hinge (A8112) TA2714 x USA US26D MK
1 Storeroom Lock (F07) AUR 8805FL K625xCT7SL 626 YA
1 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
1 Surface Closer (C02011 / C02021) R/ PR3501 (TO SUIT) 689 YA
1 Kick Plate (J102) K1050 10" CSK US32D RO
Set: 19.0
Text Box , 182, 2228 richter Cloud richter Line richter Cloud richter Line richter Rectangle richter Line richter Line richter Cloud richter
NOT USED
Section 08 71 00 Page 7
Doors: 1135
1 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
1 Surface Closer (C02021-Spg Stop) UNI3501 689 YA
1 Kick Plate (J102) K1050 10" CSK US32D RO
Set: 20.0
Doors: 233, 327, 328, 427, 428, 528, 529
1 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
1 Surface Cam Closer (C02251) 2800ST 689 NO
Set: 21.0
Doors: 122, 135, 2213
1 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
1 Surface Closer (C02011 / C02021) R/ PR3501 (TO SUIT) 689 YA
1 Kick Plate (J102) K1050 10" CSK US32D RO
Set: 22.0
Doors: 1117, 1118, 1125, 1127, 1128, 1131, 1132, 1133, 1134, 1137, 1138, 1139, 1141, 1142, 1143, 1144, 1145, 1146, 1147, 115, 1151, 1152, 1153, 116, 127, 128, 130, 131, 153, 154, 170, 171, 214, 2227, 226, 228, 230, 231, 241, 242, 243, 244, 322, 323, 325, 326, 337, 411, 412, 413, 435, 436, 438, 521, 522, 523, 524, 526, 527
1 Entry/Office Lock (F04) AUR 8807FL K625xCT7SL 626 YA
1 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
richter Cloud richter
, 181, 402
Section 08 71 00 Page 8 o STC seals by door supplier.
Set: 23.0
Doors: 150
2 Manual Flush Bolt (L04251 / L04261) 555/ 557 (TO SUIT) US26D RO
1 Storeroom Lock (F07) AUR 8805FL K625xCT7SL 626 YA
1 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
1 Surface Closer (C02011 / C02021) R/ PR3501 (TO SUIT) 689 YA
2 Kick Plate (J102) K1050 10" CSK US32D RO
2 Door Stop (L02251 / L02121) 403/470 (TO SUIT) US26D RO
Set: 24.0
Doors: 1126, 150B, 151
1 Automatic Flush Bolt (Type 27) 2848 / 2948 (TO SUIT) US32D RO
1 Classroom Lock (F05) AUR 8808FL K625xCT7SL 626 YA
1 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
1 Coordinator (Type 21A) 2600 Series (Brackets To Suit) Black RO
2 Surface Closer (C02011 / C02021) R/ PR3501 (TO SUIT) 689 YA
2 Kick Plate (J102) K1050 10" CSK US32D RO
2 Door Stop (L02251 / L02121) 403/470 (TO SUIT) US26D RO
1 Astragal (R0Y634) 357SP PE
Set: 25.0
Doors: 1154, 156
1 Classroom Lock (F05) AUR 8808FL K625xCT7SL 626 YA
1 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
Set: 26.0
Doors: 1119, 1121, 1122, 1123, 113, 1130, 114, 1149A, 1149B, 125, 145, 161, 164, 165, 167, 168, 169, 172, 173, 211, 212, 213, 2202, 2203, 2204, 2205, 2206, 2211, 2212, 222, 2229, 223, 225, 232, 311A, 311B, 319, 320, 321, 336, 414, 422A, 422B, 423, 424, 425, 426, 437, 511A, 511B, 519, 520, 537, 538
, 1126, 2211B richter Line richter Cloud richter Line richter Cloud richter Line richter Text Box , 144 richter Text Box
NOT USED
richter Rectangle richter Line richter Line richter Line
Section 08 71 00 Page 9
1 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
Set: 27.0
Doors: 129, 134, 143, 229, 324, 525
1 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
1 Surface Closer (C02011 / C02021) R/ PR3501 (TO SUIT) 689 YA
1 Kick Plate (J102) K1050 10" CSK US32D RO
Set: 28.0
Doors: 124A, 124B
1 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
1 Surface Closer (C02011 / C02021) R/ PR3501 (TO SUIT) 689 YA
Set: 29.0
Doors: 1109, 1110, 117, 118, 138, 139, 215, 216, 2218, 2219, 238, 239, 312, 313, 333, 334, 415, 416, 432, 433, 512, 514, 534, 535
1 Push Plate (J301) 70C-RKW US32D RO
1 Door Pull (J401) RM3301-13 Mtg-Type 1 US32D RO
1 Door Operator 6010 / 6020 (TO SUIT) 689 NO
1 Kick Plate (J102) K1050 10" CSK US32D RO
1 Mop Plate (J103) K1050 6" CSK US32D RO
1 Door Stop (L02251 / L02121) 403/470 (TO SUIT) US26D RO
2 Wave To Open Switch* 700 NO
Section 08 71 00 Page 10 o Electronic operation: Outside, automatic operator by wall switch. Inside, Free egress at all times by push plate/ door pull or automatic operator by wall switch.
Set: 30.0
Doors: 1105, 1107, 121, 123, 126, 136, 219, 221, 2214, 2216, 2228, 224, 234, 316, 318, 329, 338, 419, 421, 429, 516, 518, 530, 539, 179A
1 Interchangeable Core (E09241)* Match/Expand Facility Existing 626
OT
1 Electric Strike (E09321)* 1600 630 HS
1 SMART Pac Bridge Rectifier* 2005M3 HS
1 Surface Closer (C02011 / C02021) R/ PR3501 (TO SUIT) 689 YA
1 Kick Plate (J102) K1050 10" CSK US32D RO
1 Door Stop (L02251 / L02121) 403/470 (TO SUIT) US26D RO
3 Silencer (L03011) 608 RO
1 Position Switch (E08)* DPS-M-BK SU
1 Motion Sensor* XMS SU o Card reader by security integrator.
o Electronic Operation: Valid card releases electric strike or key retracts latchbolt. Request to exit shows authorized egress. Free egress at all times.
In case of power loss, door remains locked and latched.
Set: 31.0
Doors: 179B
6 Hinge (A8111) T4A3786 US32D MK
1 Removable Mullion KRM200 x LAR
X Wire Disconnect 600 YA
1 Exit Device (Type 1 F01) 7100 EO 630 YA
1 Exit Device (Type 1 F03) 7100 AU627F K645xCT7SL 630 YA
2 SFIC Core 7-Pin (E09242) As Specified 626
1 SFIC Cylinder Housing (E09251/E09261) Rim/Mortise as Required 626 YA
1 Electric Strike (E09321) 9600-LBM x2004M 630 HS
1 SMART Pac Bridge Rectifier 2005M3 HS
2 Surface Closer w/Stop (C02021 PT 4G) UNI3501 689 YA
2 Kick Plate (J102) K1050 10" 4BE CSK US32D RO
1 Threshold (J36130) 2005AT MSES25SS PE
1 Drip Strip (R0Y536) 345 ANB PE
1 Gasketing (R3E165) 2891AS (head & jambs) PE
2 Door Bottom Seal (R0Y536) 345 ANB PE
1 Astragal Set (R0Y835) 297 AS PE
3 Card Reader By security supplier BLK HD
2 Position Switch DPS-M/W-GY (as required) SU
1 Power Supply BPS (size & type as required) SU
1 Wiring Diagram Complete with point to point drawing
Notes: Electronic opening to operate as follows: Outside. Card reader
(furnished by security) signals power supply to release fail secure electric strike at active door allowing entry by lever. Key override. Inside, Free egress at all times by exit device.
richter Rectangle richter Text Box richter Cloud richter Line richter Cloud richter Text Box , 150B, 180B, 180C
Section 08 71 00 Page 11
Set: 32.0
Doors: 178B
3 Hinge (A2111) T4A3386 US32D MK
1 Exit Device (Type 1, F01) 7100 EO 630 YA
1 Surface Closer w/Stop (C02021 PT 4G) UNI3501 689 YA
1 Kick Plate (J102) K1050 10” 4BE CSK US32D RO
1 Threshold (J36130) 2005AT MSES25SS PE
1 Drip Strip (R0Y976) 346 C PE
1 Gasketing (R3E165) 2891AS (head & jambs) PE
1 Door Bottom Seal (R0Y536) 345 ANB PE
1 Position Switch DPS-M/W-GY (as required) SU
Set: 33.0
Doors: 178C
1 SFIC Core 7-Pin (E09242) As Specified 626
1 SFIC Cylinder Housing (E09251/E09261) Rim/Mortise as Required 626 YA
Notes: Balance of hardware by door supplier.
-- End of Section --
Image richter Text Box Set: 35.0 Doors: 1100A.5, 1100A.6 richter Rectangle richter Text Box richter Rectangle richter Rectangle richter Rectangle richter Text Box richter Rectangle richter Text Box richter Text Box richter Text Box richter Text Box richter Rectangle richter Text Box richter Cloud richter Text Box , S1C.1