FIRE ALARM SYMBOLS
A AMPERE
ADA AMERICANS WITH DISABILITIES ACT
AFF ABOVE FINISHED FLOOR
C CONDUIT
CKT CIRCUIT
EF EXHAUST FAN
FACP FIRE ALARM CONTROL PANEL
HP HORSEPOWER
HZ HERTZ
IDS INTRUSION DETECTION SYSTEM
JB JUNCTION BOX
KWH KILOWATT HOUR
LED LIGHT EMITTING DIODE
MCB MOLDED CASE CIRCUIT BREAKER
UNO UNLESS NOTED OTHERWISE
V VOLT
W WATTS
WP WATERPROOF
ABBREVIATIONS
FIRE ALARM AND MASS NOTIFICATION CONTROL PANEL
FIRE ALARM CONTROL PANEL
FIRE PUMP CONTROLLER
JOCKEY PUMP CONTROLLER
MASS NOTIFICATION CONTROL PANEL
NOTIFICATION APPLIANCE CIRCUIT POWER EXTENDER PANEL
LOC OPERATING CONSOLE
FIRE ALARM REMOTE ANNUNCIATOR PANEL
FIRE ALARM TRANSCEIVER
MANUAL PULL STATION; MOUNT AT 3'-10 AFF UNO
SMOKE DETECTOR (PHOTOELECTRIC TYPE). "S" INDICATES SOUNDER BASE
DUCT MOUNTED SMOKE DETECTOR (PHOTOELECTRIC TYPE)
REMOTE TEST STATION
FIRE ALARM NOTIFICATION APPLIANCE (VISUAL ONLY); #=CANDELA OUTPUT,
NO # INDICATES 15 CANDELA.
FIRE ALARM AND MASS NOTIFICATION SYSTEM SIGNAL SPEAKERS AND MASS
NOTIFICATION STROBES; MOUNT 80" AFF TO BOTTOM, '#' INDICATES CANDELA
RATING, NO NUMBER INDICATES 15 CANDELA, 'WP' INDICATES WEATHERPROOF.
PROVIDE CLEAR LENS.
MASS NOTIFICATION APPLIANCE (AUDIO ONLY). 'WP', WHEN SHOWN, INDICATES
WEATHERPROOF
CONTROL MODULE
SPRINKLER SYSTEM FLOW ALARM SWITCH
MONITOR MODULE
POST INDICATOR VALVE
PRESSURE SWITCH
FAN SHUT DOWN RELAY
TAMPER SWITCH
VALVE SUPERVISORY DEVICE (TAMPER SWITCH)
AED CABINET AND DEVICE. DEVICE AND CABINET ARE GOVERNMENT PROVIDED
AND GOVERNMENT INSTALLED. SUPERVISORY CONNECTION REQUIRED BY
CONTRACTOR.
LED EMERGENCY MESSAGE DISPLAY SIGN, SEE DETAILS THIS SHEET
F
SD
DD
RTS
F
M
CM
FS
MM
PIV
PS
SR
VS
WP
S
LOC
TYP TYPICAL
AED AUTOMATED EXTERNAL DEFIBRILLATOR
WP
FAA
NAC
MNCP
FPCP
FACP
JPCP
TS
FTR FIRE ALARM TRANSCEIVER
FTR
FACP/MNCP
PIV POST INDICATOR VALVE
FM FLOW METER
AV ALTITUDE VALVE
JPCP JOCKEY PUMP CONTROL PANEL
FDC FIRE DEPARTMENT CONNECTION
FIRE PROTECTION SYMBOL LEGEND
- WET PIPE SYSTEM PIPING
- UPRIGHT SPRINKLER
- PENDENT SPRINKLER
- HORIZONTAL DRY SIDEWALL SPRINKLER
- PIPE RISE ABOVE
- DROP FROM BOTTOM OF PIPE
- PIPE TURNS DOWN
- PIPE CAP/PLUG
- OS&Y GATE VALVE WITH ELECTRONIC SUPERVISORY DEVICEVS
- WATER FLOW SWITCHFS
- FIRE DEPARTMENT CONNECTION
- ZONE CONTROL ASSEMBLYZC
- FIRE HYDRANT
DS
- HOSE STATION, MANUAL WET STANDPIPE
- WALL MOUNTED TEST HEADER
- FIRE PUMP WITH DRIVES
J - PRESSURE MAINTENANCE PUMPS
- FIRE PUMP CONTROLLERFPC
- HAZARD CATEGORY 1HC-1
- HAZARD CATEGORY 2HC-2
- HAZARD CATEGORY 3HC-3
- CHECK VALVE
1. PROVIDE DESIGN AND INSTALLATION OF FIRE PROTECTION SYSTEM IN
ACCORDANCE WITH UFC 3-600-01 (CHANGE 3, 01 MARCH 2013), APPLICABLE
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) CODE REQUIREMENTS
INCLUDING NFPA 13 (2013 EDITION).
2. PROVIDE HYDRAULICALLY DESIGNED AUTOMATIC FIRE SPRINKLER SYSTEMS
USING THE FOLLOWING DESIGN BASIS:
HC-2: INCLUDES ALL AREAS.
- DESIGN DENSITY: 0.20 GPM/SQ. FT. OVER MOST REMOTE 2500 SQ. FT.
- INCLUDE 250 GPM HOSE STREAM ALLOWANCE.
FIRE PROTECTION GENERAL NOTES
SW
IT
CH
4"
S
QU
AR
E
JB
FO
R
VO
IC
E
OU
TL
ET
46"
FINISHED FLOOR
4"
(TYP)
TYPICAL FIRE PROTECTION DEVICE MOUNTING HEIGHTS DETAIL
DIMENSIONS INDICATED ARE
MINIMUMS AND SHALL BE
FOLLOWED UNLESS NOTED
OTHERWISE ON THE PLANS.
SCALE: NTS
CENTER FIXTURES ABOVE DOOR
FRAME. COORDINATE WITH
ELECTRICAL BEFORE ROUGH-IN
EDGE OF DOOR FRAME
(OR DOOR SIDELIGHT
WHERE APPLICABLE)
FA
P
UL
L
ST
AT
IO
N
80"
SP
EA
KE
R/
ST
RO
BE
4"
(TYP)
LED EMERGENCY
MESSAGE DISPLAY SIGN,
SEE DETAIL THIS SHEET
CEILING
4" (TYP)
108"
DOORWAY
LED EMERGENCY MESSAGE DISPLAY SIGN
EVACUATE
ANNOUNCEMENT
14 1/2"
8"
2"
SCALE: NTS
NOTE:
1. DIMENSIONS ARE APPROXIMATE.
US Army Corps of Engineers ®
SHEET ID
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
D
AT
E
TI
M
E
ST
AM
P:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
PR
O
JE
C
T N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
PROPERTY OF UNITED STATES GOVERNMENT, FOR OFFICIAL USE ONLY (FOUO). COPYING, DISSEMINATION, AND DISTRIBUTION TO UNAUTHORIZED INDIVIDUALS PROHIBITED.
4/
/2
7:
:3
AM
F-002
PHASE 3
FI
R
E
PR
O
TE
C
TI
O N
F
IR
E
AL
AR
M L
EG
EN
D A
N D
AB
BR
EV
IA
TI
O
N S
B
AT
TA
LI
O N
C O
M
PL
EX
VO
LU
M
E
N O
R
FO
LK
D
IS
TR
IC
T
N O
R
FO
LK
, V
A
R . N
AG
EL
E.
M
O R
TO
N
R . N
AG
EL
M . M
AR
KL
EY
JA
N
U
AR
Y
R
TA
S U
BM
IT
TA
L
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AM
E N D
M
EN
T
AP
R
2 0
F
F
F
F
SD
PUMP ROOM
BA
D
C
FIRE PUMP CONTROLLER
PANEL #1
JOCKEY PUMP
CONTROL
PANEL(JPCP)
FTR
FACP/MNCP
FIRE PUMP CONTROLLER
PANEL #2
FIRE PUMP CONTROLLER
PANEL #3
FIRE PUMP #3
(FP-3)
FIRE PUMP #2
(FP-2)
FIRE PUMP #1
(FP-1)
TRENCH
(TYPICAL)
TRENCH
TRENCH
HP-4 PAD
MOUNT BOTTOM OF
FIXTURE 6'-6" AFF
MOUNT BOTTOM OF
FIXTURE 6'-6" AFF
PUMP ROOM
FIRE PUMP TEST
HEADERS (TYP)
12" LINE FROM
WATER DISTRIBUTION
SYSTEM
16" LINE TO HANGAR
BA
D
HC-2
C
FLEXIBLE JOINT, SEE DETAIL
ON SHEET F-521 (TYPICAL)
POST INDICATING VALVE (PIV),
SEE CIVIL FOR DETAIL
(TYPICAL)
6" FEED MAIN SERVING
SPRINKLER SYSTEM
TRENCH
(TYP)
TRENCH
TRENCH
ALTITUDE VALVE
FIRE PUMP #3
(FP-3)
FIRE PUMP #2
(FP-2)
FIRE PUMP #1
(FP-1)
WATER STORAGE
TANK (WT-2)
JOCKEY PUMP
ISOLATION VALVE
CHECK VALVE
RELIEF VALVE
ISOLATION
VALVE
WATER STORAGE
TANK (WT-1)
SURGE ARRESTOR, SEE
TYPICAL ISOMETRIC PUMP
DETAIL ON SHEET F-623
2 1/2" SIAMESE FIRE
DEPARTMENT CONNECTION
ALARM CHECK VALVE
WALL MOUNTED POST
INDICATING VALVE
FLOW
METER
HP-4 PAD
US Army Corps of Engineers ®
SHEET ID
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
D
AT
E
TI
M
E
ST
AM
P:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
PR
O
JE
C
T N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
PROPERTY OF UNITED STATES GOVERNMENT, FOR OFFICIAL USE ONLY (FOUO). COPYING, DISSEMINATION, AND DISTRIBUTION TO UNAUTHORIZED INDIVIDUALS PROHIBITED.
4/
/2
:4 4:
P
M
F-141
PHASE 3
FI
R
E
PU
M P
BL
D
G
SP
R
IN
KL
ER
F
IR
E
AL
AR
M
M
AS
S
N O
TI
FI
C
AT
IO
N
S
YS
TE
M
F
LO
O R
P
LA
N S
B
AT
TA
LI
O N
C O
M
PL
EX
VO
LU
M
E
N O
R
FO
LK
D
IS
TR
IC
T
N O
R
FO
LK
, V
A
R . N
AG
EL
E.
M
O R
TO
N
R . N
AG
EL
R . K
U
ST
O W
SK
I
JA
N
U
AR
Y
R
TA
S U
BM
IT
TA
L
SCALE: 1/8" = 1'-0"
FIRE PUMP BLDG. - FIRE ALARM / MASS
NOTIFICATION SYSTEM FLOOR PLAN
8' 16' 24'
SCALE: 1/8" = 1' - 0"
0'
NO SCALE
NORTH
KEY PLAN
FIRE PUMP BLDG.
SCALE: 1/8" = 1'-0"
FIRE PUMP BLDG. - SPRINKLER FLOOR PLAN
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AM
E N D
M
EN
T
AP
R
2 0
FIRE ALARM / MASS NOTIFICATION RISER DIAGRAM
GENERAL NOTES (THIS DRAWING ONLY)
FSVS
SCALE: NTS
BATTERY CHARGER
BATTERY
LA
LOCAL
ANNUNCIATOR
LOCAL CALL
STATION WITH
HANDSET
SIGNALING LINE CIRCUIT, CLASS A
PROVIDE #6 COPPER GROUND TO
GROUNDING ELECTRODE SYSTEM
REQUIRED AUDIO ACTIVATION
LINK FROM TRANSCEIVER
PROVIDE #6
COPPER GROUND
TO GROUNDING
ELECTRODE SYSTEM
PROVIDE #6 COPPER
GROUND TO GROUNDING
ELECTRODE SYSTEM
EXTERIOR ANTENNA. REFER TO
MONACO REQUIREMENTS
FOR INSTALLATION DETAILS
LIGHTNING ARRESTER
POWER SUPPLY CIRCUITS
POWER SUPPLY
CIRCUIT
NOTIFICATION APPLIANCE CIRCUIT
BATTERY
BATTERY CHARGER
BATTERYBATTERY
WP
ADDRESSABLE
FIRE ALARM / MNS
CONTROL PANEL
(FACP / FMCP)
LOCAL
ANNUNCIATOR
MONACO BTX-M
SERIES 16 ZONE
TRANSCEIVER WITH
AUDIO CARD
(FTR)
M
SD
F F
1. PROVIDE ALL NECESSARY ADDRESSABLE MONITOR AND CONTROL MODULES FOR
NON-ADDRESSABLE DEVICES THAT REQUIRE CONNECTION TO THE FACP.
2. ALL SPRINKLER SYSTEM WATERFLOW AND TAMPER SWITCHES SHALL BE FULLY
SUPERVISED BY THE FIRE ALARM CONTROL PANEL AND TESTED.
3. PROVIDE ALL ACCESSORY FUNCTIONS INCLUDING INTERCONNECTING RELAYS,
FAN SHUTDOWN CONNECTIONS AND TEST.
4. CONNECT MASS NOTIFICATION SYSTEM TO FA SYSTEM TO PROVIDE TEMPORARY
DEACTIVATION OF AUDIBLE AND VISUAL FIRE ALARM APPLIANCES FOR MASS
NOTIFICATION MESSAGES AND TO SUPERVISE MASS NOTIFICATION CONTROL
PANEL AND/OR REQUIRED POWER SUPPLIES.
5. PROVIDE MASS NOTIFICATION SYSTEM WITH THE ABILITY TO BE CONNECTED
TO A NETWORK TYPE CAMPUS-WIDE CONTROL SYSTEM IN THE FUTURE.
THE CONTROL PANEL SHALL BE CAPABLE OF RECEIVING BOTH VOICE AND DATA.
6. PROVIDE SURGE PROTECTORS, LIGHTNING ARRESTORS AND OTHER PROTECTIVE
DEVICES ON ALL CIRCUITS AND EQUIPMENT AS REQUIRED BY NFPA 72 AND BY
EQUIPMENT MANUFACTURER'S.
7. PROVIDE FIRE ALARM AND MASS NOTIFICATION AS ONE SYSTEM.
8. PROVIDE SEPARATION BETWEEN THE OUTGOING AND RETURN CABLES PER
NFPA 72, 23.4.2.2. PROVIDE 4 FEET BETWEEN OUTGOING AND RETURN WHERE
THE CABLE IS INSTALLED HORIZONTALLY AND 1 FOOT WHERE THE CABLE IS
INSTALLED VERTICALLY.
9. PROVIDE SMOKE DETECTOR AT LOCATION OF FIRE ALARM CONTROL PANELS.
10. PROVIDE PLENUM RATED CABLE.
11. DIAGRAM SHOWN IS SCHEMATIC IN NATURE ONLY. CONTRACTOR IS RESPONSIBLE
FOR DESIGNING SYSTEM PER PROJECT CRITERIA.
TS
US Army Corps of Engineers ®
SHEET ID
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
D
AT
E
TI
M
E
ST
AM
P:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
PR
O
JE
C
T N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
PROPERTY OF UNITED STATES GOVERNMENT, FOR OFFICIAL USE ONLY (FOUO). COPYING, DISSEMINATION, AND DISTRIBUTION TO UNAUTHORIZED INDIVIDUALS PROHIBITED.
4/
/2
7:
:3
AM
F-622
PHASE 3
FI
R
E
AL
AR
M
M
AS
S
N O
TI
FI
C
AT
IO
N
R
IS
ER
D
IA
G
R
AM
B
AT
TA
LI
O N
C O
M
PL
EX
VO
LU
M
E
N O
R
FO
LK
D
IS
TR
IC
T
N O
R
FO
LK
, V
A
R . N
AG
EL
E.
M
O R
TO
N
R . N
AG
EL
M . M
AR
KL
EY
JA
N
U
AR
Y
R
TA
S U
BM
IT
TA
L
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AM
E N D
M
EN
T
AP
R
2 0
| BC-PH3 VOL 3 FIRE PUMP BLDG - FP/FA AMENDMENT 005 |
| F-002 - FIRE PROTECTION & FIRE ALARM LEGEND AND ABBREVIATIONS |
| F-141 - FIRE PUMP BLDG. - SPRINKLER & FIRE ALARM / MASS NOTIFICATION SYSTEM FLOOR PLANS |
| F-622 - FIRE ALARM / MASS NOTIFICATION RISER DIAGRAM |
File details come from the government source that posted it. Updated .