719_BC -PH2-A-601.pdf

PDF 87 KB Posted

Attached to
Battalion Complex (Amendment 8)
Solicitation number
W9123620R0001
Issued by

View the file

Other files

File Type Posted
W9123620R0001P0008 - Amendment 8.pdf PDF
18245_ - AREA T - POWER.pdf PDF
A.07.24 - W9123620R0001(Amendment 7).pdf PDF
W9123620R0001 Amendment 6.pdf PDF
719_BC-PH2_SF423.pdf PDF
719_BC-PH2_MP121.pdf PDF
719_BC-PH2_SF600(Amend5).pdf PDF
720_BC-PH3-S504.pdf PDF
719_BC-PH2_26 20 00.pdf PDF
719_BC-PH2_MP111.pdf PDF
719_BC_PH2_Sheet A-200.pdf PDF
719_BC_Sheet - I-003.pdf PDF
719_BC-PH2_SF505.pdf PDF
719_BC-PH2_MP122.pdf PDF
720_BC-PH3-CS103.pdf PDF
719_BC-PH2_MP116.pdf PDF
719_BC-PH2_SF422.pdf PDF
719_BC_Sheet - I-223.pdf PDF
05 12 00.pdf PDF
22 00 00.pdf PDF
720_BC-PH3-CU102.pdf PDF
719_BC_PH2_Sheet A-412.pdf PDF
720_BC-PH3-S215 (1).pdf PDF
719_BC_FFE_PH2_Amendment 5 sheets(Amend5).pdf PDF
719_BC-PH2_SF420.pdf PDF
719_BC-PH2 Sheet EP404.pdf PDF
26 51 00.pdf PDF
719_BC-PH2_SF425.pdf PDF
10 28 13.pdf PDF
23 65 00.pdf PDF
28 31 76.pdf PDF
719_BC_Sheet - I-008.pdf PDF
AMEND005-719_BC-PH2_FA001-FA126.pdf PDF
719_BC-PH2_03 30 00.00 10.pdf PDF
719_BC-PH2_10 21 13.pdf PDF
PH1 TWS TWR piping routing.pdf PDF
720_BC-PH3-SF600.pdf PDF
720_BC_PH3_EL119-EL123_EL502.pdf PDF
719_BC-PH2_FA001_FA111-FA114.pdf PDF
719_BC_Sheet - I-124.pdf PDF
719_BC -PH2-A- 603.pdf PDF
719_BC_PH2_Sheet A-411.pdf PDF
720_BC_PH3_FP001_FP140-FP143.pdf PDF
719_BC-PH2_SF421.pdf PDF
719_BC-PH2_SB106.pdf PDF
720_BC_PH3_A-605.pdf PDF
719_BC-PH2_MP113.pdf PDF
719_BC-PH2_11 46 01.06.pdf PDF
719_BC-PH2_S-001(Amend5).pdf PDF
719_BC-PH2_M-401.pdf PDF
Show 40 more

Latest 50 of 136 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F G N OHDCBA R

AS

S

C H

ED

U

LE

D

AS SCHEDULED

AS SCHEDULED

AS

S

C H

ED

U

LE

D

AS

S

C H

ED

U

LE

D

AS SCHEDULED

AS

S

C H

ED

U

LE

D

AS SCHEDULED

AS

S

C H

ED

U

LE

D

AS SCHEDULED

AS

S

C H

ED

U

LE

D

AS SCHEDULEDAS SCHEDULED

AS

S

C H

ED

U

LE

D

AS

S

C H

ED

U

LE

D

AS SCHEDULED

AS

S

C H

ED

U

LE

D

AS SCHEDULED

26" 4" 6"

6"

6" 24" 6"

6"

2"

AS SCHEDULED

2"

2"

AS

S C

H

ED

U

LE

D

2 3

AS SCHEDULED

2" 2" AS SCHEDULED 2"

4"

AS

S C

H

ED

U

LE

D

AS

S

C H

ED

U

LE

D

2"

2" AS SCHEDULED 2"

AS

S

C H

ED

U

LE

D

4"

2" REMOVABLE

CENTER MULLION

2" REMOVABLE

CENTER MULLION

2"

AS

S C

H

ED

U

LE

D

2"

AS SCHEDULED

2"

2"

AS

S C

H

ED

U

LE

D 2"

AS

S

C H

ED

U

LE

D

SIDELIGHT

2"

AS SCHEDULED

2"

AS SCHEDULED

2"

5 6 7

AS SCHEDULED

AS

S

C H

ED

U

LE

D

5' - 3"

3"3"

GENERAL NOTES

1. SEE INTERIOR FINISH LEGEND AND EXTERIOR COLOR

LEGEND FOR PAINT FINISH INFORMATION.

2. OPENINGS THAT REQUIRES SPECIALTY DOOR AND

FRAMES SHALL BE PROVIDED AND INSTALLED AS

COMPLETE ASSEMBLIES, INCLUDING DOOR, FRAME, AND

HARDWARE, FROM A SINGLE MANUFACTURER. THIS

INCLUDES SOUND CONTROL, BLAST-RATED, RF-SHIELDED,

ARMS VAULT, AND FOODSERVICE LOCATIONS.

3. GLAZING, WHERE REQUIRED, SHALL BE FACTORY

INSTALLED. FIELD CUTTING IS NOT ALLOWED.

4. SEE SPECIFICATIONS FOR HARDWARE SCHEDULE.

5. SEE SPECIFICATIONS FOR LEVEL REQUIREMENTS AT

STEEL DOORS.

6. SEE SECURITY DRAWINGS FOR ADDITIONAL INFORMATION.

COMMENTS

1. INSULATED DOOR(S) AND FRAME(S).

2. THERMALLY BROKEN FRAME.

3. UNDERCUT DOORS 3/4".

4. ATFP BLAST OPENING.

5. RF-SHIELDED OPENING.

6. CLASS 5A VAULT DOOR ASSEMBLY.

7. CLASS 5A VAULT DOOR ASMBLY W/ STANDARD DAY GATE.

8. ELECTRONIC ACCESS CONTROL HARDWARE IN NIC AND

SHALL BE PROVIDED AND INSTALLED THROUGH A SEPERATE

CONTRACT. PREPARE DOOR AND FRAME AS REQUIRED FOR

FUTURE INSTALLATION OF INDICATED HARDWARE BY

OTHERS. DOOR HARDWARE SETS AFFECTED INCLUDE: 1.0,

2.0, 4.0, 7.0, 8.0, 9.0, 11.0, 12.0, 13.0, 14.0, 15.0, 16.0. rEFER TO

SPECIFICATIONS FOR MORE INFORMATION

9. EXIT ONLY DOOR.

10. ONE LEAF FIXED, ONE LEAF ACTIVE.

11. DOORS ON HOLD OPEN. COORDINATE WITH FIRE ALARM

DRAWINGS.

12. ADVANCED PERFORMANCE INSULATED OVERHEAD DOOR,

MIN. R-10, WITH ADDITIONAL PERIMETER SEALS TO REDUCE

AIR INFILTRATION TO LESS THAN 1.0 CFM/FT2.

13. FOOD SERVICE DOUBLE-SWINGING DOOR AND DOUBLE-

ACTING FRAME.

14. DOUBLE EGRESS FRAME.

15. GLAZING TO BE 1" INSULATED LAMINATED GLASS.

16. ALUMINUM SLIDING GLASS DOOR (HEAVY COMMERICAL

GRADE).

17. HEAVY DUTY SWING DOOR W/ AUTOMATIC OPERATOR.

18. NOT USED.

19. NOT USED.

20. GLAZING TO BE 5/8"

21. GLAZING TO BE 1/4" FIRE-RATED GLASS.

22. FRP/ ALUMINUM HYBRID DOOR.

23. BARN DOOR STYLE SLIDING DOOR AND FRAME

24. MANUAL PUSH UP OPERATION.

25. ELECTRIC OPERATION WITH CONTROL SWITCHES LOCATED

INSIDE BUILDING.

26. A MONUMENTAL, HIGH PERFORMANCE SLIDING DOOR FOR

LOW, MEDIUM OR HIGH RISE APPLICATIONS OFFERING

PERFORMANCE RATINGS TO HC-120. IT IS IMPACT AND

CYCLE TESTED FOR SMALL MISSILE APPLICATIONS TO MEET

THE DEMANDS OF COASTAL INSTALLATIONS. AVAILABLE IN

A VARIETY OF CONFIGURATIONS.

27. PAINT DOOR AND FRAME TO MATCH WALL.

28. BUILT TO ORDER METAL SLATTED ROLLING DOORS SECURE

OPENINGS ABOVE COUNTERS. CAN FULLY CLOSE TO THE

FLOOR.

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

RS

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

D

AT

E

TI

M

E

ST

AM

P:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

PR

O

JE

C

T N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

PROPERTY OF UNITED STATES GOVERNMENT, FOR OFFICIAL USE ONLY (FOUO). COPYING, DISSEMINATION, AND DISTRIBUTION TO UNAUTHORIZED INDIVIDUALS PROHIBITED.

4/

/2

:0 9:

A

M

A-601

PHASE 2

D O

O R

S C

H

ED

U

LE

T

YP

ES

B

AT

TA

LI

O N

C O

M

PL

EX

N

O R

FO

LK

D

IS

TR

IC

T N

O R

FO

LK

, V A

E.

W hi te

B.

H ak ey

D . G eb le r

D . G eb le r

JA

N

U

AR

Y

R

TA

S U

BM

IT

TA

L

SCALE: 1/4" = 1'-0"

DOOR TYPES

SCALE: 1/4" = 1'-0"

FRAME TYPES 4' 8' 12'

SCALE: 1/4" = 1' - 0"

0'

DOOR SCHEDULE

DOOR

NO.

DOOR FRAME

STC

RATING

FIRE

RATING HW SET COMMENTS:

SIZE

MATERIAL FINISH TYPE

PAIR (PR)

SINGLE (S) LEVEL TYPE MATERIAL FINISH

DETAILS

WIDTH HEIGHT THICKNESS HEAD JAMB SILL

0001A 3' - 0" 7' - 0" 2 1/4" ALUM ANODIZE B S BLAST 2 HM ANODIZE - - 2.0 2, 4, 8, 15 0001B 3' - 0" 7' - 0" 2 1/4" ALUM ANODIZE B S BLAST 2 HM ANODIZE - - 3.0 2, 4, 9, 15

0002 3' - 0" 7' - 0" 1 3/4" HM PNT F PR 3 4 HM PNT - - 12.0 8, 10

0003 3' - 0" 7' - 0" 1 3/4" HM PNT F S 4 2 HM PNT - - 5.0 1, 8

0004 3' - 0" 7' - 0" 1 3/4" HM PNT F PR 4 4 HM PNT - - 5.0 1, 8

0006 8' - 0" 8' - 0" 1 1/2" STL SATIN OH S - - - - - - 72.0 12, 24

0007 3' - 0" 7' - 0" 1 3/4" HM PNT F S BLAST 2 HM PNT - - 7.0 1, 4, 8

0008 3' - 0" 7' - 0" 1 3/4" HM PNT F S 4 2 HM PNT - - 7.0 1, 8

0009 12' - 0" 12' - 0" 3/4" STL BAKED OH S - - - - - - 72.0 1, 25

0010 12' - 0" 12' - 0" 3/4" STL BAKED OH S - - - - - - 72.0 1, 25

0011 3' - 0" 7' - 0" 1 3/4" HM PNT F S BLAST 2 HM PNT - - 13.0 1

0012 8' - 0" 10' - 0" 1 1/2" SS SATIN OH S - - - - - - 72.0 12, 25

0013 3' - 0" 7' - 0" 1 3/4" HM PNT F S 4 2 HM PNT - - 8.0 1, 8

0014 3' - 0" 7' - 0" 1 3/4" HM PNT F S 4 2 HM PNT - - 8.0 1, 8

0017 3' - 0" 7' - 0" 1 3/4" HM PNT F S 4 2 HM PNT - 45 Minute 11.0 1, 8

0018 3' - 0" 7' - 0" 1 3/4" HM PNT F S BLAST 2 HM PNT - - 7.0 1, 4, 9

0019 3' - 0" 7' - 0" 1 3/4" HM PNT F S 4 6 STL PNT - - 14.0 1

0020 8' - 0" 8' - 0" 3/4" STL BAKED OH S - - - - - - 72.0 1, 24

0021 3' - 0" 7' - 0" 1 3/4" HM PNT F PR 4 4 HM PNT - - 6.0 1, 10

0022 3' - 0" 7' - 0" 1 3/4" HM PNT F PR 4 4 HM PNT - - 6.0 1, 10

0023 3' - 0" 7' - 0" 1 3/4" HM PNT F S 4 2 HM PNT - - 8.0 1, 8

0024 7' - 0" 7' - 0" 2 7/8" OTHER NONE A S BLAST - - PNT - - 4.0 26

0032 14' - 6 1/2" 5' - 7" 3/4" STL BAKED OH S - - - PNT - - - 28

1001 3' - 0" 7' - 0" GLAS CLEAR R PR - ISF2 ALUM ANODIZE - - 72.0 16

1002 3' - 0" 7' - 0" 1 3/4" HM PNT F PR 3 3 HM PNT 49 45 Minute 78.0 11, 14

1003A 3' - 0" 7' - 0" 1 3/4" HM PNT F S 3 1 HM PNT - - 31.0 8

1003B 3' - 0" 7' - 0" 1 3/4" HM PNT F S 3 1 HM PNT - - 32.0 9

1004 3' - 6" 7' - 0" 2 1/4" ALUM ANODIZE B S - 2 ALUM ANODIZE - - 18.0 2, 15

1005 3' - 0" 7' - 0" 2 1/4" ALUM ANODIZE B S - 2 ALUM ANODIZE - - 18.0 2, 15

1006 3' - 0" 7' - 0" 1 3/4" FRP FRP N PR - 4 FRP FRP - - 27.0 2, 15, 17

1008A 3' - 0" 7' - 0" 1 3/4" HM PNT F S 3 1 HM PNT - - 31.0 8

1008B 3' - 0" 7' - 0" 1 3/4" HM PNT F S 3 1 HM PNT - - 32.0 9

1010 3' - 0" 7' - 0" 1 3/4" HM PNT F PR 3 3 HM PNT - 45 Minute 30.0 11, 14 1100 3' - 6" 7' - 0" 1 3/4" HM PNT N S - 2 HM PNT - 45 Minute 48.0 8

1101 3' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 45 - 63.0 3

1102A 3' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 47 - 44.0 8

1102B 3' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 47 - 73.0

1104 3' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 47 - 40.0 8

1105 4' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 50 - 69.0

1106 4' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 50 - 69.0

1107 4' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 50 - 69.0

1108 4' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 50 - 69.0

1109 3' - 0" 7' - 0" 1 3/4" HM PNT F S 1 1 HM PNT - - 54.0 3

1110 2' - 6" 7' - 0" 1 3/4" HM PNT F S 1 1 HM PNT - - 53.0 3

1111 2' - 6" 7' - 0" 1 3/4" HM PNT F S 1 1 HM PNT - - 54.0 3

1112 3' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 47 - 40.0 8

1113 3' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 47 - 40.0 8

1114 4' - 0" 7' - 0" 1 3/4" HM PNT F S 4 1 HM PNT - - 26.0 1, 2, 8

1115 4' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 50 - 69.0

1116 4' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 50 - 69.0

1117 3' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 47 - 44.0 8

1118 3' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 47 - 60.0 8

1119 3' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 49 45 Minute 60.0 3

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AM

E N D

M

EN

T

-1 7-

2 0

AM

E N D

M

EN

T

-2 2-

2 0

File details come from the government source that posted it. Updated .