719_BC -PH2-A-601.pdf
PDF 87 KB Posted
- Attached to
- Battalion Complex (Amendment 8)
- Solicitation number
- W9123620R0001
View the file
Other files
Show 40 more
Latest 50 of 136 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F G N OHDCBA R
AS
S
C H
ED
U
LE
D
AS SCHEDULED
AS SCHEDULED
AS
S
C H
ED
U
LE
D
AS
S
C H
ED
U
LE
D
AS SCHEDULED
AS
S
C H
ED
U
LE
D
AS SCHEDULED
AS
S
C H
ED
U
LE
D
AS SCHEDULED
AS
S
C H
ED
U
LE
D
AS SCHEDULEDAS SCHEDULED
AS
S
C H
ED
U
LE
D
AS
S
C H
ED
U
LE
D
AS SCHEDULED
AS
S
C H
ED
U
LE
D
AS SCHEDULED
26" 4" 6"
6"
6" 24" 6"
6"
2"
AS SCHEDULED
2"
2"
AS
S C
H
ED
U
LE
D
2 3
AS SCHEDULED
2" 2" AS SCHEDULED 2"
4"
AS
S C
H
ED
U
LE
D
AS
S
C H
ED
U
LE
D
2"
2" AS SCHEDULED 2"
AS
S
C H
ED
U
LE
D
4"
2" REMOVABLE
CENTER MULLION
2" REMOVABLE
CENTER MULLION
2"
AS
S C
H
ED
U
LE
D
2"
AS SCHEDULED
2"
2"
AS
S C
H
ED
U
LE
D 2"
AS
S
C H
ED
U
LE
D
SIDELIGHT
2"
AS SCHEDULED
2"
AS SCHEDULED
2"
5 6 7
AS SCHEDULED
AS
S
C H
ED
U
LE
D
5' - 3"
3"3"
GENERAL NOTES
1. SEE INTERIOR FINISH LEGEND AND EXTERIOR COLOR
LEGEND FOR PAINT FINISH INFORMATION.
2. OPENINGS THAT REQUIRES SPECIALTY DOOR AND
FRAMES SHALL BE PROVIDED AND INSTALLED AS
COMPLETE ASSEMBLIES, INCLUDING DOOR, FRAME, AND
HARDWARE, FROM A SINGLE MANUFACTURER. THIS
INCLUDES SOUND CONTROL, BLAST-RATED, RF-SHIELDED,
ARMS VAULT, AND FOODSERVICE LOCATIONS.
3. GLAZING, WHERE REQUIRED, SHALL BE FACTORY
INSTALLED. FIELD CUTTING IS NOT ALLOWED.
4. SEE SPECIFICATIONS FOR HARDWARE SCHEDULE.
5. SEE SPECIFICATIONS FOR LEVEL REQUIREMENTS AT
STEEL DOORS.
6. SEE SECURITY DRAWINGS FOR ADDITIONAL INFORMATION.
COMMENTS
1. INSULATED DOOR(S) AND FRAME(S).
2. THERMALLY BROKEN FRAME.
3. UNDERCUT DOORS 3/4".
4. ATFP BLAST OPENING.
5. RF-SHIELDED OPENING.
6. CLASS 5A VAULT DOOR ASSEMBLY.
7. CLASS 5A VAULT DOOR ASMBLY W/ STANDARD DAY GATE.
8. ELECTRONIC ACCESS CONTROL HARDWARE IN NIC AND
SHALL BE PROVIDED AND INSTALLED THROUGH A SEPERATE
CONTRACT. PREPARE DOOR AND FRAME AS REQUIRED FOR
FUTURE INSTALLATION OF INDICATED HARDWARE BY
OTHERS. DOOR HARDWARE SETS AFFECTED INCLUDE: 1.0,
2.0, 4.0, 7.0, 8.0, 9.0, 11.0, 12.0, 13.0, 14.0, 15.0, 16.0. rEFER TO
SPECIFICATIONS FOR MORE INFORMATION
9. EXIT ONLY DOOR.
10. ONE LEAF FIXED, ONE LEAF ACTIVE.
11. DOORS ON HOLD OPEN. COORDINATE WITH FIRE ALARM
DRAWINGS.
12. ADVANCED PERFORMANCE INSULATED OVERHEAD DOOR,
MIN. R-10, WITH ADDITIONAL PERIMETER SEALS TO REDUCE
AIR INFILTRATION TO LESS THAN 1.0 CFM/FT2.
13. FOOD SERVICE DOUBLE-SWINGING DOOR AND DOUBLE-
ACTING FRAME.
14. DOUBLE EGRESS FRAME.
15. GLAZING TO BE 1" INSULATED LAMINATED GLASS.
16. ALUMINUM SLIDING GLASS DOOR (HEAVY COMMERICAL
GRADE).
17. HEAVY DUTY SWING DOOR W/ AUTOMATIC OPERATOR.
18. NOT USED.
19. NOT USED.
20. GLAZING TO BE 5/8"
21. GLAZING TO BE 1/4" FIRE-RATED GLASS.
22. FRP/ ALUMINUM HYBRID DOOR.
23. BARN DOOR STYLE SLIDING DOOR AND FRAME
24. MANUAL PUSH UP OPERATION.
25. ELECTRIC OPERATION WITH CONTROL SWITCHES LOCATED
INSIDE BUILDING.
26. A MONUMENTAL, HIGH PERFORMANCE SLIDING DOOR FOR
LOW, MEDIUM OR HIGH RISE APPLICATIONS OFFERING
PERFORMANCE RATINGS TO HC-120. IT IS IMPACT AND
CYCLE TESTED FOR SMALL MISSILE APPLICATIONS TO MEET
THE DEMANDS OF COASTAL INSTALLATIONS. AVAILABLE IN
A VARIETY OF CONFIGURATIONS.
27. PAINT DOOR AND FRAME TO MATCH WALL.
28. BUILT TO ORDER METAL SLATTED ROLLING DOORS SECURE
OPENINGS ABOVE COUNTERS. CAN FULLY CLOSE TO THE
FLOOR.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
RS
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
D
AT
E
TI
M
E
ST
AM
P:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
PR
O
JE
C
T N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
PROPERTY OF UNITED STATES GOVERNMENT, FOR OFFICIAL USE ONLY (FOUO). COPYING, DISSEMINATION, AND DISTRIBUTION TO UNAUTHORIZED INDIVIDUALS PROHIBITED.
4/
/2
:0 9:
A
M
A-601
PHASE 2
D O
O R
S C
H
ED
U
LE
T
YP
ES
B
AT
TA
LI
O N
C O
M
PL
EX
N
O R
FO
LK
D
IS
TR
IC
T N
O R
FO
LK
, V A
E.
W hi te
B.
H ak ey
D . G eb le r
D . G eb le r
JA
N
U
AR
Y
R
TA
S U
BM
IT
TA
L
SCALE: 1/4" = 1'-0"
DOOR TYPES
SCALE: 1/4" = 1'-0"
FRAME TYPES 4' 8' 12'
SCALE: 1/4" = 1' - 0"
0'
DOOR SCHEDULE
DOOR
NO.
DOOR FRAME
STC
RATING
FIRE
RATING HW SET COMMENTS:
SIZE
MATERIAL FINISH TYPE
PAIR (PR)
SINGLE (S) LEVEL TYPE MATERIAL FINISH
DETAILS
WIDTH HEIGHT THICKNESS HEAD JAMB SILL
0001A 3' - 0" 7' - 0" 2 1/4" ALUM ANODIZE B S BLAST 2 HM ANODIZE - - 2.0 2, 4, 8, 15 0001B 3' - 0" 7' - 0" 2 1/4" ALUM ANODIZE B S BLAST 2 HM ANODIZE - - 3.0 2, 4, 9, 15
0002 3' - 0" 7' - 0" 1 3/4" HM PNT F PR 3 4 HM PNT - - 12.0 8, 10
0003 3' - 0" 7' - 0" 1 3/4" HM PNT F S 4 2 HM PNT - - 5.0 1, 8
0004 3' - 0" 7' - 0" 1 3/4" HM PNT F PR 4 4 HM PNT - - 5.0 1, 8
0006 8' - 0" 8' - 0" 1 1/2" STL SATIN OH S - - - - - - 72.0 12, 24
0007 3' - 0" 7' - 0" 1 3/4" HM PNT F S BLAST 2 HM PNT - - 7.0 1, 4, 8
0008 3' - 0" 7' - 0" 1 3/4" HM PNT F S 4 2 HM PNT - - 7.0 1, 8
0009 12' - 0" 12' - 0" 3/4" STL BAKED OH S - - - - - - 72.0 1, 25
0010 12' - 0" 12' - 0" 3/4" STL BAKED OH S - - - - - - 72.0 1, 25
0011 3' - 0" 7' - 0" 1 3/4" HM PNT F S BLAST 2 HM PNT - - 13.0 1
0012 8' - 0" 10' - 0" 1 1/2" SS SATIN OH S - - - - - - 72.0 12, 25
0013 3' - 0" 7' - 0" 1 3/4" HM PNT F S 4 2 HM PNT - - 8.0 1, 8
0014 3' - 0" 7' - 0" 1 3/4" HM PNT F S 4 2 HM PNT - - 8.0 1, 8
0017 3' - 0" 7' - 0" 1 3/4" HM PNT F S 4 2 HM PNT - 45 Minute 11.0 1, 8
0018 3' - 0" 7' - 0" 1 3/4" HM PNT F S BLAST 2 HM PNT - - 7.0 1, 4, 9
0019 3' - 0" 7' - 0" 1 3/4" HM PNT F S 4 6 STL PNT - - 14.0 1
0020 8' - 0" 8' - 0" 3/4" STL BAKED OH S - - - - - - 72.0 1, 24
0021 3' - 0" 7' - 0" 1 3/4" HM PNT F PR 4 4 HM PNT - - 6.0 1, 10
0022 3' - 0" 7' - 0" 1 3/4" HM PNT F PR 4 4 HM PNT - - 6.0 1, 10
0023 3' - 0" 7' - 0" 1 3/4" HM PNT F S 4 2 HM PNT - - 8.0 1, 8
0024 7' - 0" 7' - 0" 2 7/8" OTHER NONE A S BLAST - - PNT - - 4.0 26
0032 14' - 6 1/2" 5' - 7" 3/4" STL BAKED OH S - - - PNT - - - 28
1001 3' - 0" 7' - 0" GLAS CLEAR R PR - ISF2 ALUM ANODIZE - - 72.0 16
1002 3' - 0" 7' - 0" 1 3/4" HM PNT F PR 3 3 HM PNT 49 45 Minute 78.0 11, 14
1003A 3' - 0" 7' - 0" 1 3/4" HM PNT F S 3 1 HM PNT - - 31.0 8
1003B 3' - 0" 7' - 0" 1 3/4" HM PNT F S 3 1 HM PNT - - 32.0 9
1004 3' - 6" 7' - 0" 2 1/4" ALUM ANODIZE B S - 2 ALUM ANODIZE - - 18.0 2, 15
1005 3' - 0" 7' - 0" 2 1/4" ALUM ANODIZE B S - 2 ALUM ANODIZE - - 18.0 2, 15
1006 3' - 0" 7' - 0" 1 3/4" FRP FRP N PR - 4 FRP FRP - - 27.0 2, 15, 17
1008A 3' - 0" 7' - 0" 1 3/4" HM PNT F S 3 1 HM PNT - - 31.0 8
1008B 3' - 0" 7' - 0" 1 3/4" HM PNT F S 3 1 HM PNT - - 32.0 9
1010 3' - 0" 7' - 0" 1 3/4" HM PNT F PR 3 3 HM PNT - 45 Minute 30.0 11, 14 1100 3' - 6" 7' - 0" 1 3/4" HM PNT N S - 2 HM PNT - 45 Minute 48.0 8
1101 3' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 45 - 63.0 3
1102A 3' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 47 - 44.0 8
1102B 3' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 47 - 73.0
1104 3' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 47 - 40.0 8
1105 4' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 50 - 69.0
1106 4' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 50 - 69.0
1107 4' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 50 - 69.0
1108 4' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 50 - 69.0
1109 3' - 0" 7' - 0" 1 3/4" HM PNT F S 1 1 HM PNT - - 54.0 3
1110 2' - 6" 7' - 0" 1 3/4" HM PNT F S 1 1 HM PNT - - 53.0 3
1111 2' - 6" 7' - 0" 1 3/4" HM PNT F S 1 1 HM PNT - - 54.0 3
1112 3' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 47 - 40.0 8
1113 3' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 47 - 40.0 8
1114 4' - 0" 7' - 0" 1 3/4" HM PNT F S 4 1 HM PNT - - 26.0 1, 2, 8
1115 4' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 50 - 69.0
1116 4' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 50 - 69.0
1117 3' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 47 - 44.0 8
1118 3' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 47 - 60.0 8
1119 3' - 0" 7' - 0" 1 3/4" HM PNT F S 2 1 HM PNT 49 45 Minute 60.0 3