18245_ - AREA T - POWER.pdf

PDF 222 KB Posted

Attached to
Battalion Complex (Amendment 8)
Solicitation number
W9123620R0001
Issued by

View the file

Other files

File Type Posted
W9123620R0001P0008 - Amendment 8.pdf PDF
A.07.24 - W9123620R0001(Amendment 7).pdf PDF
W9123620R0001 Amendment 6.pdf PDF
719_BC-PH2_SF423.pdf PDF
719_BC-PH2_MP121.pdf PDF
719_BC -PH2-A-601.pdf PDF
719_BC-PH2_SF600(Amend5).pdf PDF
720_BC-PH3-S504.pdf PDF
719_BC-PH2_26 20 00.pdf PDF
719_BC-PH2_MP111.pdf PDF
719_BC_PH2_Sheet A-200.pdf PDF
719_BC_Sheet - I-003.pdf PDF
719_BC-PH2_SF505.pdf PDF
719_BC-PH2_MP122.pdf PDF
720_BC-PH3-CS103.pdf PDF
719_BC-PH2_MP116.pdf PDF
719_BC-PH2_SF422.pdf PDF
719_BC_Sheet - I-223.pdf PDF
05 12 00.pdf PDF
22 00 00.pdf PDF
720_BC-PH3-CU102.pdf PDF
719_BC_PH2_Sheet A-412.pdf PDF
720_BC-PH3-S215 (1).pdf PDF
719_BC_FFE_PH2_Amendment 5 sheets(Amend5).pdf PDF
719_BC-PH2_SF420.pdf PDF
719_BC-PH2 Sheet EP404.pdf PDF
26 51 00.pdf PDF
719_BC-PH2_SF425.pdf PDF
10 28 13.pdf PDF
23 65 00.pdf PDF
28 31 76.pdf PDF
719_BC_Sheet - I-008.pdf PDF
AMEND005-719_BC-PH2_FA001-FA126.pdf PDF
719_BC-PH2_03 30 00.00 10.pdf PDF
719_BC-PH2_10 21 13.pdf PDF
PH1 TWS TWR piping routing.pdf PDF
720_BC-PH3-SF600.pdf PDF
720_BC_PH3_EL119-EL123_EL502.pdf PDF
719_BC-PH2_FA001_FA111-FA114.pdf PDF
719_BC_Sheet - I-124.pdf PDF
719_BC -PH2-A- 603.pdf PDF
719_BC_PH2_Sheet A-411.pdf PDF
720_BC_PH3_FP001_FP140-FP143.pdf PDF
719_BC-PH2_SF421.pdf PDF
719_BC-PH2_SB106.pdf PDF
720_BC_PH3_A-605.pdf PDF
719_BC-PH2_MP113.pdf PDF
719_BC-PH2_11 46 01.06.pdf PDF
719_BC-PH2_S-001(Amend5).pdf PDF
719_BC-PH2_M-401.pdf PDF
Show 40 more

Latest 50 of 136 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MECHANICAL EQUIPMENT CONNECTION SCHEDULE

TAG MCA LOAD MOCP VOLTS Ø CIRCUIT # CONNECTION CONDUIT AND WIRE NOTES

OAVAV-1501 120 1 SEE PLAN INTEGRAL SWITCH 2 #12, 1#12 GND - 1/2"C 1

OAVAV-1502 120 1 SEE PLAN INTEGRAL SWITCH 2 #12, 1#12 GND - 1/2"C 1

WAHP-1501 3.7 15 277 1 HM2-1444-22 MOTOR RATED SWITCH 2 #12, 1 #12 GND - 1/2"C 1

WAHP-1502 11.2 15 277 1 HM2-1444-24 MOTOR RATED SWITCH 2 #12, 1 #12 GND - 1/2"C 1

WAHP-1504 10.5 15 277 1 HM2-1444-26 MOTOR RATED SWITCH 2 #12, 1 #12 GND - 1/2"C 1

RP 1/6 HP 20 120 1 SEE PLAN MOTOR RATED SWITCH 2 #12, 1 #12 GND - 1/2"C 1

CP-10 75W 20 120 1 SEE PLAN MOTOR RATED SWITCH 2 #12, 1 #12 GND - 1/2"C 1

FCP-1 15 HP 480 3 SERVICE LATERAL CONTROL PANEL 3 #8, 1 #10 GND - 1/2"C 2

FCP-2 15 HP 480 3 SERVICE LATERAL CONTROL PANEL 3 #8, 1 #10 GND - 1/2"C 2

HD3 17.7 (3) 5HP 70 480 3 HG2-1454-37 60A-3P NFSS 3#4, 1#8GND - 1"C

TH1 57.0 38kW 60 480 3 HM1-1493-32 100A-3P NFSS 3 #2, 1 #4 GND - 1 1/2"C

NOTES:

1. COORDINATE ALL CONNECTIONS TO EQUIPMENT WITH MECHANICAL SUB-CONTRACTOR AND APPROVED SHOP DRAWINGS.

2. CONNECT TO AND EXTEND FIRE PUMP UNDERGROUND RACEWAY PROVIDED IN PHASE 1 OF PROJECT.

PHASE 1 RACEWAY IS IN PLACE FROM CEP EAST TO WITHIN 5' OF THE SOUTHWEST CORNER

OF THIS BUILDING'S LIMIT (+/- 300 FT). PROVIDE FEEDER CONDUCTORS FROM PUMP CONTROLLER

TO SWITCHBOARD IN CEP EAST.

E

D E F F.05 F.1 F.2 F.3

1.3

1.2

1.1

2.0

D.1

0.1

1.0

E

WAHP-1502

OAVAV-1502

WAHP-1501

G

G

G

G

G

G

EE

RP

CP-10

RP

FCP-2

FCP-1

SNOW MELTING

CONTROL PANEL

FOAM CONTROL PANEL

M A

T C

H

LI

N E

A

R E

A S

E E

S H

E E

T E

L1

M A

T C

H

LI

N E

A

R E

U

E

S H

E E

T E

L1

M A

T C

H

LI

N E

A

R E

E

S H

E E

T E

L1

LG2-1444-1

SERVICE RACK 'F.05'

A - HG1-1454-1

B - HG1-1454-7

C - HG1-1454-2

D - HG1-1454-8

E - LG1-1454-9

F - LG1-1454-11

G - LG1-1454-18

H - LG1-1454-20

J - LG1-1454-22

K - LG1-1454-24

LG2-1444-2

LM1-1461-7

BALANCE

TOOL ROOM

MECH/FIRE

LG2-1444-4

LG2-1444-6

OVERHEAD DOOR

480V, 3Ø

HM2-1444-1

30A-3P, NF

MATCHLINE - AREA K

SEE SHEET EP114

MATCHLINE - AREA L

SEE SHEET EP115 MATCHLINE - AREA M

SEE SHEET EP116

HD3

HANGAR DOOR

CONTROLLER

TH1

WAHP-1504

LG2-1444-3 1 AIRCRAFT SERVICE POINT RACK. SEE DETAILS ON SHEET EP501 FOR

MORE INFORMATION.

CONNECTION TO EMERGENCY SHOWER & EYE WASH STATION ALARM;

120V, 1Ø.

HANGAR AREA IS A CLASS 1 DIVISION 1

HAZARDOUS AREA FROM FLOOR TO

18" AFF

A I

N I

G

RI

VFOHTLAE

W

N O

M M

O C

P R

O F

ESS I ONAL ENG

I N

E E

R

N

8' 16' 24'

SCALE: 1/8" = 1' - 0"

0'

SCALE: NTS

KEY PLAN

Q R S TPHASE 2

G H J K L M N P

VU

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S D

R A

W N

B Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

D

A T

E

T

IM

E S

T A

M P

IS

S

U E

D A

T E

C O

N T

R A

C T

N

O

P R

O J E

C T

N O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

PROPERTY OF UNITED STATES GOVERNMENT, FOR OFFICIAL USE ONLY (FOUO). COPYING, DISSEMINATION, AND DISTRIBUTION TO UNAUTHORIZED INDIVIDUALS PROHIBITED.

JAMES E. BARKLEY, JR.

Lic. No. 043854

01/10/20

/6

/2

:4

:2

A M

EP122

PHASE 3

F

IR

S T

F L O

O R

P L A

N

A R

E A

T

P O

W E

R

B A

T T

A L

IO

N

C O

M P

L E

X N

O R

F O

L K

D

IS

T R

IC

T

N O

R F

O L

K

V A

M L

IN

D A

L E

A R

A M

O S

B W

O O

D

J B

A R

K L E

Y

J A

N U

A R

Y

R T

A S

U B

M

IT

T A

L

SCALE: 1/8" = 1'-0"

FIRST FLOOR PLAN - AREA T - POWER

NOTES THIS SHEET

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A m e n d m e n t

/2

/2

A m e n d m e n t

/2

/2

Sheets
EP122 - FIRST FLOOR PLAN - AREA T - POWER

File details come from the government source that posted it. Updated .