719_BC-PH2_SF420.pdf

PDF 99 KB Posted

Attached to
Battalion Complex (Amendment 8)
Solicitation number
W9123620R0001
Issued by

View the file

Other files

File Type Posted
W9123620R0001P0008 - Amendment 8.pdf PDF
18245_ - AREA T - POWER.pdf PDF
A.07.24 - W9123620R0001(Amendment 7).pdf PDF
W9123620R0001 Amendment 6.pdf PDF
719_BC-PH2_SF423.pdf PDF
719_BC-PH2_MP121.pdf PDF
719_BC -PH2-A-601.pdf PDF
719_BC-PH2_SF600(Amend5).pdf PDF
720_BC-PH3-S504.pdf PDF
719_BC-PH2_26 20 00.pdf PDF
719_BC-PH2_MP111.pdf PDF
719_BC_PH2_Sheet A-200.pdf PDF
719_BC_Sheet - I-003.pdf PDF
719_BC-PH2_SF505.pdf PDF
719_BC-PH2_MP122.pdf PDF
720_BC-PH3-CS103.pdf PDF
719_BC-PH2_MP116.pdf PDF
719_BC-PH2_SF422.pdf PDF
719_BC_Sheet - I-223.pdf PDF
05 12 00.pdf PDF
22 00 00.pdf PDF
720_BC-PH3-CU102.pdf PDF
719_BC_PH2_Sheet A-412.pdf PDF
720_BC-PH3-S215 (1).pdf PDF
719_BC_FFE_PH2_Amendment 5 sheets(Amend5).pdf PDF
719_BC-PH2 Sheet EP404.pdf PDF
26 51 00.pdf PDF
719_BC-PH2_SF425.pdf PDF
10 28 13.pdf PDF
23 65 00.pdf PDF
28 31 76.pdf PDF
719_BC_Sheet - I-008.pdf PDF
AMEND005-719_BC-PH2_FA001-FA126.pdf PDF
719_BC-PH2_03 30 00.00 10.pdf PDF
719_BC-PH2_10 21 13.pdf PDF
PH1 TWS TWR piping routing.pdf PDF
720_BC-PH3-SF600.pdf PDF
720_BC_PH3_EL119-EL123_EL502.pdf PDF
719_BC-PH2_FA001_FA111-FA114.pdf PDF
719_BC_Sheet - I-124.pdf PDF
719_BC -PH2-A- 603.pdf PDF
719_BC_PH2_Sheet A-411.pdf PDF
720_BC_PH3_FP001_FP140-FP143.pdf PDF
719_BC-PH2_SF421.pdf PDF
719_BC-PH2_SB106.pdf PDF
720_BC_PH3_A-605.pdf PDF
719_BC-PH2_MP113.pdf PDF
719_BC-PH2_11 46 01.06.pdf PDF
719_BC-PH2_S-001(Amend5).pdf PDF
719_BC-PH2_M-401.pdf PDF
Show 40 more

Latest 50 of 136 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

0"

FIRST FLOOR

16' - 8"

SECOND FLOOR

1113141617 1215 12.814.314.916.3

C O

N

ST

J T

CONST JT

CONST JT

C O

N T

JT

C O

N T

JT

C O

N T

JT

C O

N T

JT

C O

N T

JT

C O

N T

JT

C O

N

ST

J T

C O

N

ST

J T

C O

N

ST

J T

C O

N

ST

J T

C O

N T

JT

C O

N T

JT

4'-0" DOWEL AT 1'-0" OC AT VERT CONST JT ONLY.

CAST END INTO ONE SIDE; GREASE AND SLEEVE OPPOSITE END

CONST JT CONST JTCONST JT

CONST JTCONST JT

CONST JT

ALTERNATE CONT REINF EVERY

OTHER ROW AT CONT JT ONLY

(2) #5 T&B OF OPNGS TYP (2)#5 JAMB BARS TYP

C O

N T

JT

8' - 7" 8' - 7" 8' - 2"

BASE BIDBID OPTION POOL

BASE BIDBID OPTION POOL

6'

0" 8'

0"

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

RS

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

D

AT

E

TI

M

E

ST

AM

P:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

PR

O

JE

C

T N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

PROPERTY OF UNITED STATES GOVERNMENT, FOR OFFICIAL USE ONLY (FOUO). COPYING, DISSEMINATION, AND DISTRIBUTION TO UNAUTHORIZED INDIVIDUALS PROHIBITED.

4/

/2

3:

:1

PM

SF420

PHASE 2

C O

N C

R

ET

E W

AL

L

EL

VA

TI

O

N S

G R

ID

C

B

AT

TA

LI

O N

C O

M

PL

EX

N

O R

FO

LK

D

IS

TR

IC

T N

O R

FO

LK

, V A

J.

J

O N

ES

C . S

AN

D

ER

S

C . S

AN

D

ER

S

W . M

IL

LE

R

JA

N

U

AR

Y

R

TA

S U

BM

IT

TA

L

3/16" = 1'-0"SF420

1 CONCRETE WALL ELEVATION C

0'

SCALE: 3/16" = 1' - 0"

4' 8' 12' 16'

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AM

E N D

M

EN

T

-0 4-

1 6

CONCRETE WALL ELEVATION NOTES

1. THE MINIMUM REINFORCEMENT IS INDICATED IN 1/SF505, AND IS NOT ALL SHOWN ON THESE

ELEVATIONS. WHERE REINFORCEMENT IS NOT OTHERWISE SHOWN ON THESE

ELEVATIONS, PROVIDE THE MINIMUM REINFORCEMENT FROM 1/SF505.

2. VERTICAL CONSTRUCTION JOINT AND CONTROL JOINT LOCATIONS ARE SHOWN

ON THE PLANS. FOR CONSTRUCTION AND CONTROL JOINT DETAILS, SEE SF505.

DO NOT SUBSTITUTE VERTICAL CONSTRUCTION JOINTS FOR CONTROL JOINTS OR

VISE VERSA WITHOUT APPROVAL OF THE ENGINEER OF RECORD FOR THE LOCATION

REQUESTED.

3. VERTICAL CONTROL JOINTS HAVE BEEN LAID OUT SUCH THAT IF THE WALL IS

POURED FULL HEIGHT IN ONE POUR (MULTIPLE LIFTS), VOLUMES OF POUR WILL

USUALLY FALL BETWEEN 30-40 CUBIC YARDS (CY). SOME POURS IF PERFORMED

FULL HEIGHT WILL APPROACH 50 CY. DO NOT PERFORM SINGLE POURS GREATER

THAN 50 CY WITHOUT APPROVAL OF THE ENGINEER OF RECORD AND THE

CONTRACT OFFICER.

4. ALL HORIZONTAL JOINTS SHOWN AS CONSTRUCTION JOINTS MAY BE CONSTRUCTED

AS CONTROL JOINTS, PROVIDED THE SINGLE POUR VOLUME LIMITS OF NOTE 3

AND THE INDIVIDUAL LIFT LIMITS OF ACI ARE OBSERVED. INTERCHANGEABILITY BETWEEN

HORIZONTAL CONTROL AND CONSTRUCTION JOINTS IS INTENDED TO ALLOW THE

CONTRACTOR FLEXIBILITY TO PLAN INDIVIDUAL POURS OF A SIZE THAT IS CONSITENT

WITH THEIR QUALITY CONTROL PLAN AND CREW ABILITY TO MAINTAIN QUALITY FOR

LARGER POURS.

5. VAULT WALLS HAVE A REINFORCING SIZE AND SPACING THAT DIFFERS FROM THE

DEFAULT REINFORING ON 1/SF505. FOR VAULT WALL LOCATIONS, SEE PLAN ON

SB106.

Sheets
SF420 - CONCRETE WALL ELVATIONS GRID C