720_BC_PH3_EP130_EP401-EP402_EP501.pdf

PDF 1 MB Posted

Attached to
Battalion Complex (Amendment 8)
Solicitation number
W9123620R0001
Issued by

View the file

Other files

File Type Posted
W9123620R0001P0008 - Amendment 8.pdf PDF
18245_ - AREA T - POWER.pdf PDF
A.07.24 - W9123620R0001(Amendment 7).pdf PDF
W9123620R0001 Amendment 6.pdf PDF
719_BC-PH2_SF423.pdf PDF
719_BC-PH2_MP121.pdf PDF
719_BC -PH2-A-601.pdf PDF
719_BC-PH2_SF600(Amend5).pdf PDF
720_BC-PH3-S504.pdf PDF
719_BC-PH2_26 20 00.pdf PDF
719_BC-PH2_MP111.pdf PDF
719_BC_PH2_Sheet A-200.pdf PDF
719_BC_Sheet - I-003.pdf PDF
719_BC-PH2_SF505.pdf PDF
719_BC-PH2_MP122.pdf PDF
720_BC-PH3-CS103.pdf PDF
719_BC-PH2_MP116.pdf PDF
719_BC-PH2_SF422.pdf PDF
719_BC_Sheet - I-223.pdf PDF
05 12 00.pdf PDF
22 00 00.pdf PDF
720_BC-PH3-CU102.pdf PDF
719_BC_PH2_Sheet A-412.pdf PDF
720_BC-PH3-S215 (1).pdf PDF
719_BC_FFE_PH2_Amendment 5 sheets(Amend5).pdf PDF
719_BC-PH2_SF420.pdf PDF
719_BC-PH2 Sheet EP404.pdf PDF
26 51 00.pdf PDF
719_BC-PH2_SF425.pdf PDF
10 28 13.pdf PDF
23 65 00.pdf PDF
28 31 76.pdf PDF
719_BC_Sheet - I-008.pdf PDF
AMEND005-719_BC-PH2_FA001-FA126.pdf PDF
719_BC-PH2_03 30 00.00 10.pdf PDF
719_BC-PH2_10 21 13.pdf PDF
PH1 TWS TWR piping routing.pdf PDF
720_BC-PH3-SF600.pdf PDF
720_BC_PH3_EL119-EL123_EL502.pdf PDF
719_BC-PH2_FA001_FA111-FA114.pdf PDF
719_BC_Sheet - I-124.pdf PDF
719_BC -PH2-A- 603.pdf PDF
719_BC_PH2_Sheet A-411.pdf PDF
720_BC_PH3_FP001_FP140-FP143.pdf PDF
719_BC-PH2_SF421.pdf PDF
719_BC-PH2_SB106.pdf PDF
720_BC_PH3_A-605.pdf PDF
719_BC-PH2_MP113.pdf PDF
719_BC-PH2_11 46 01.06.pdf PDF
719_BC-PH2_S-001(Amend5).pdf PDF
Show 40 more

Latest 50 of 136 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DN

TV

TV

TV

TV

TV

J

J

J

J

J

TV

J

TM

D

T

T

NO SCALE

NO SCALE

1. ROOM SIZE VARIES.

2. FOR EACH AREA OF 100 SQ FT, OR PART THERE OF, PROVIDE A MINIMUM OF ONE INTERIOR PEDESTAL BOND, CONNECT TO PERIMETER CONDUCTOR WITH #2 BARE CUPPER CONDUCTOR OR PROVIDE CONTINUOUS BARE

#1/0 CONDUCTOR ACROSS ROOM AT 10' ON CENTER AND BOND TO INTERIOR PEDESTALS AT 10' INTERVALS.

3. ALL COPPER TO COPPER CONNECTIONS SHALL BE BY EKOTHERMIC WEDO OR BY USE OF H-TAP

COMPRESSION CONDUCTOR INSTALLED BY USE OF HYDRAULIC COMPRESSION TOOL. MECHANICAL

CONNECTORS ROD NOT ACCEPTABLE.

4. ALL EQUIPMENT ON RAISED FLOOR SHALL BE BONDED TO FLOOR GROUNDING CONDUCTORS.

PERIMETER PEDESTAL BOND

TYPICAL RAISED FLOOR GROUNDING DETAIL

#4 BARE COPPER

GROUNDING CABLE

GROUNDING CLAMP

TYPICAL PERIMETER

PEDESTAL BOND. SEE DETAIL

THIS SHEET

#1/0 BARE COPPER

BONDED TO ALL

PERIMETER PEDESTALS

#1/0 BARE COPPER TO

BUILDING PERIMETER

COUNTERPOISE

CONDUCTOR. TYPICAL

FOR FOUR, LOCATED

EQUIDISTANT AROUND

PERIMETER

RAISED FLOOR SUPPORT

PEDESTAL, TYP.

TYPICAL INTERIOR LEG BOND.

SEE DETAIL THIS SHEET.

24" TYP.

24" TYP.

#4 BARE COPPER

GROUNDING CABLE

GROUNDING CLAMP

#1/0 COPPER CONDUCTOR BONDING

ALL EQUIPMENT OR RAISED FLOOR

TYPICAL

SERVER

COMMO OPEN OFFICE

COMMO FILES

OFFICE

OFFICE

FACILITIES OFFICE

TR

FACILITIES OPEN OFFICE

ELEC

MECH

CORRIDOR

EP402

EP402

O A

V A

V -2

WAHP-2428

WAHP-2427

WAHP-2432

WAHP-2434

C.3 C.4 C.5 D E

3.1

2.0

4.0

D.1

BFI BFI

BFI BFI

RP

RP

O A

V A

V -2

RPRP

O A

V A

V -2

EP130

LUP-2434-1

2 8

25 23

35 37 39 41

211 7

LG1-2434-7

LG1-2434-9

C R

A C

-3

W A

H P

-2

LUP-2434-3

LUP-2434-5

LUP-2434-7

R P

1 1

"HM1-2435"

C.5

"LG6-2434"

"LG5-2434"

"LG4-2434"

"LUP-2434"

ELEC

"LG1-2434" "LG2-2434" "LG3-2434"

"HG1-2434"

"TG1-2434"

"TG2-2434"

UNLESS OTHERWISE NOTED, ALL 120V

BRANCH CIRCUITS ON PLAN SHALL BE

SERVED FROM PANEL LG2-2434

1 NOT USED

2 BOND RAISED FLOORING SYSTEM.

SEE DETAILS THIS SHEET.

A I

N I

G

RI

VFOHTLAE

W

N O

M M

O C

P R

O F

ESS I ONAL ENG

I N

E E

R

N

4' 8' 12'

SCALE: 1/4" = 1' - 0"

0'8' 16' 24'

SCALE: 1/8" = 1' - 0"

0'

SCALE: NTS

KEY PLAN

Q R S TPHASE 2

G H J K L M N P

VU

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S D

R A

W N

B Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

D

A T

E

T

IM

E S

T A

M P

IS

S

U E

D A

T E

C O

N T

R A

C T

N

O

P R

O J E

C T

N O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

PROPERTY OF UNITED STATES GOVERNMENT, FOR OFFICIAL USE ONLY (FOUO). COPYING, DISSEMINATION, AND DISTRIBUTION TO UNAUTHORIZED INDIVIDUALS PROHIBITED.

JAMES E. BARKLEY, JR.

Lic. No. 043854

01/10/20

/2

/2

:4

:3

P

M

EP130

PHASE 3

S E

C O

N D

F L O

O R

P L A

N

A R

E A

K

P O

W E

R

B A

T T

A L

IO

N

C O

M P

L E

X N

O R

F O

L K

D

IS

T R

IC

T

N O

R F

O L

K

V A

M

L

IN

D A

L E

A

R A

M O

S

B

W O

O D

J B

A R

K L

E Y

J A

N U

A R

Y

R T

A S

U B

M

IT

T A

L

SCALE: 1/8" = 1'-0"

SECOND FLOOR PLAN - AREA K - POWER

SCALE: 1/4" = 1'-0" EP130

3 ENLARGED ELECTRIC ROOM 2434 PLAN

NOTES THIS SHEET

1. COORDINATE ALL CONNECTIONS TO EQUIPMENT WITH MECHANICAL SUB-CONTRACTOR AND APPROVED SHOP DRAWINGS.

NOTES:

CRAC-3 97.4 110 480 3 HG1-2434-31 200A-3P, FU@110 3 #2, 1 #6 GND - 1 1/4"C 1,2

RP 1/6 HP 20 120 1 SEE PLAN MOTOR RATED SWITCH 2 #12, 1 #12 GND - 1/2"C 1

WAHP-2434 10.5 15 277 1 HM1-2435-13 MOTOR RATED SWITCH 2 #12, 1 #12 GND - 1/2"C 1

WAHP-2432 11.2 15 277 1 HM1-2435-11 MOTOR RATED SWITCH 2 #12, 1 #12 GND - 1/2"C 1

WAHP-2431 10.5 15 277 1 HM1-2435-9 MOTOR RATED SWITCH 2 #12, 1 #12 GND - 1/2"C 1

WAHP-2428 3.7 15 277 1 HM1-2435-7 MOTOR RATED SWITCH 2 #12, 1 #12 GND - 1/2"C 1

WAHP-2427 6.2 15 480 3 HM1-2435-1 30A-3P, FU @ 15A 4 #12, 1#12 GND - 1/2"C 1

OAVAV-2432 120 1 SEE PLAN INTEGRAL SWITCH 2 #12, 1#12 GND - 1/2"C 1

OAVAV-2428 120 1 SEE PLAN INTEGRAL SWITCH 2 #12, 1#12 GND - 1/2"C 1

OAVAV-2427 120 1 SEE PLAN INTEGRAL SWITCH 2 #12, 1#12 GND - 1/2"C 1

TAG MCA LOAD MOCP VOLTS Ø CIRCUIT # CONNECTION CONDUIT AND WIRE NOTES

MECHANICAL EQUIPMENT CONNECTION SCHEDULE

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A m e n d m e n t

/2

/2

A m e n d m e n t

/2 /2

2. INCLUDED IN BID ITEM

MECHANICAL EQUIPMENT CONNECTION SCHEDULE

TAG MCA LOAD MOCP VOLTS Ø CIRCUIT # CONNECTION CONDUIT AND WIRE NOTES

P-3 50 HP 480 3 HG1-1136-7 100A-3P, NF SS 3 #2, 1#6 GND - 1-1/2"C 1

NOTES:

1. COORDINATE ALL CONNECTIONS TO EQUIPMENT WITH MECHANICAL SUB-CONTRACTOR AND APPROVED SHOP DRAWINGS.

P-3

3.1

1.3

2.0

V F

D

P-3

EXISTING 'HG1-1136'

EXISTING 'LG1-1136'

1 COORDINATE PUMP LOCATION WITH MECHANICAL CONTRACTOR PRIOR

TO ROUGH-IN.

PROVIDE 3P-125A BREAKER IN EXISTING SPACE INDICATED.2

A I

N I

G

RI

VFOHTLAE

W

N O

M M

O C

P R

O F

ESS I ONAL ENG

I N

E E

R

N

8' 16' 24'

SCALE: 1/8" = 1' - 0"

0'

SCALE: NTS

KEY PLAN

Q R S TPHASE 2

G H J K L M N P

PHASE 2 MECH ROOM

VU

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S D

R A

W N

B Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

D

A T

E

T

IM

E S

T A

M P

IS

S

U E

D A

T E

C O

N T

R A

P R

O J E

C T

N O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

PROPERTY OF UNITED STATES GOVERNMENT, FOR OFFICIAL USE ONLY (FOUO). COPYING, DISSEMINATION, AND DISTRIBUTION TO UNAUTHORIZED INDIVIDUALS PROHIBITED.

JAMES E. BARKLEY, JR.

Lic. No. 043854

01/10/20

/2

/2

:4

:3

P

M

EP401

PHASE 3

E N

L A

R G

E D

P L A

N S

B A

T T

A L

IO

N

C O

M P

L E

X N

O R

F O

L K

D

IS

T R

IC

T

N O

R F

O L

K

V A

M

L

IN

D A

L E

A

R A

M O

S

B

W O

O D

J B

A R

K L

E Y

J A

N U

A R

Y

R T

A S

U B

M

IT

T A

L

SCALE: 1/8" = 1'-0"

1 ENLARGED MECHANICAL ROOM (PHASE 2)

NOTES THIS SHEET

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A m e n d m e n t

/2 /2

NOTES THIS PLAN

J T

G2

MAXIMUM OF FOUR CAGES PER CIRCUIT.

T

C R

C

C

C

C R

C R

CR

S s

C

C R

C

TR

WAHP-1408

LUP-1408-12

LUP-1408-4

LUP-1408-8

LUP-1408-16

"LUP-1408"

LUP-1408-3

LUP-1408-1

LUP-1408-9

LUP-1408-11

LUP-1408-5

LUP-1408-7

NEMA L6-20,

78" AFF,

TYP U.O.N.

78" AFF

78" AFF

78" AFF

78" AFF

+60" AFFLUP-1408-13

W A

H P

-1

"LUP-1443"

TR

LUP-1443-4

LUP-1443-9LUP-1443-8

LUP-1443-16

LUP-1443-1

LUP-1443-3

LUP-1443-5

LUP-1443-7

LUP-1443-11 LUP-1443-12

78" AFF

78" AFF

78" AFF

78" AFF

TR

W A

H P

-1

"LUP-1469"

LUP-1469-1

LUP-1469-3

LUP-1469-4

LUP-1469-12

LUP-1469-8

LUP-1469-16

LUP-1469-7

LUP-1469-11

LUP-1469-5

LUP-1469-9

TR

W A

H P

-2

"LUP-2431"

LUP-2431-4

LUP-2431-12

LUP-2431-8

LUP-2431-16

LUP-2431-1

LUP-2431-3

LUP-2431-7

LUP-2431-11

LUP-2431-5

LUP-2431-9

78" AFF

78" AFF

SERVER

C R

A C

-1

120/208V, 30A, TYP.

"UPS2-2429""UPS1-2429"

"UPS1-2429"

UPS1-2429-48

UPS1-2429-44UPS1-2429-51UPS1-2429-47

UPS1-2429-43

UPS2-2429-42

UPS1-2429-2

UPS1-2429-21

UPS1-2429-17

UPS1-2429-13

UPS1-2429-9

UPS1-2429-5

UPS1-2429-1

UPS2-2429-1

UPS1-2429-14

UPS1-2429-10

UPS1-2429-6

UPS1-2429-42

"UPS2-2429"

NEMA L14-30, TYP.

3#10, 1#10GND-3/4", TYP.

UPS2-2429-14

UPS2-2429-10

UPS2-2429-6

UPS2-2429-2UPS2-2429-21

UPS2-2429-17

UPS2-2429-13

UPS2-2429-9

UPS2-2429-5

UPS2-2429-48

UPS2-2429-44UPS2-2429-51

UPS2-2429-47

UPS2-2429-43

LG1-2434-12 2

TR

W A

H P

-2

"LUP-2459"

LUP-2459-4

LUP-2459-12

LUP-2459-8

LUP-2459-16

LUP-2459-3

LUP-2459-1

LUP-2459-5

LUP-2459-7

LUP-2459-11

LUP-2459-9

78" AFF

78" AFF

NOTE:

FOR MECHANICAL EQUIPMENT

CIRCUITING SEE FLOOR PLANS.

WAHP-2406

"LUP-2406"

LUP-2406-16

LUP-2406-12

LUP-2406-8

LUP-2406-4

LUP-2406-1

LUP-2406-3

TR

LUP-2406-5

LUP-2406-7

LUP-2406-11

LUP-2406-9

78" AFF

78" AFF

1 INSTALL TWIST LOCK NEMA OUTLET ON BOTTOM OF CABLE TRAY ABOVE

RACK. PROVIDE MATCHING RECEPTACLE WITH 10'-0" OF 4-CORD, 10/CA 50

CABLE TO SUPPLY IN RACK PDU.

PROVIDE MUSHROOM HEAD EPO PUSHBUTTON. CONNECT TO MCB

SHUNTRIP IN PANELS UPS1-2429 AND UPS2-2429.

A I

N I

G

RI

VFOHTLAE

W

N O

M M

O C

P R

O F

ESS I ONAL ENG

I N

E E

R

4' 8' 12'

SCALE: 1/4" = 1' - 0"

0'

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S D

R A

W N

B Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

D

A T

E

T

IM

E S

T A

M P

IS

S

U E

D A

T E

C O

N T

R A

P R

O J E

C T

N O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

PROPERTY OF UNITED STATES GOVERNMENT, FOR OFFICIAL USE ONLY (FOUO). COPYING, DISSEMINATION, AND DISTRIBUTION TO UNAUTHORIZED INDIVIDUALS PROHIBITED.

JAMES E. BARKLEY, JR.

Lic. No. 043854

01/10/20

/2

/2

:4

:3

P

M

EP402

PHASE 3

E N

L A

R G

E D

P L A

N S

B A

T T

A L

IO

N

C O

M P

L E

X N

O R

F O

L K

D

IS

T R

IC

T

N O

R F

O L

K

V A

M L

IN

D A

L E

A R

A M

O S

B W

O O

D

J B

A R

K L E

Y

J A

N U

A R

Y

R T

A S

U B

M

IT

T A

L

SCALE: 1/4" = 1'-0" EP112

2 ENLARGED TR 1408 PLAN

SCALE: 1/4" = 1'-0" EP114

3 ENLARGED TR 1443 PLAN

SCALE: 1/4" = 1'-0" EP116

4 ENLARGED TR 1469 PLAN

SCALE: 1/4" = 1'-0" EP130

6 ENLARGED TR 2431 PLAN

SCALE: 1/4" = 1'-0" EP130

7 ENLARGED SERVER 2429 PLAN

SCALE: 1/4" = 1'-0" EP132

8 ENLARGED TR 2459 PLAN

SCALE: 1/4" = 1'-0" EP128

5 ENLARGED TR 2406 PLAN

NOTES THIS PLAN

78" AFF

78" AFF

NEMA L6-20,

78" AFF,

TYP U.O.N.

NEMA L6-20,

78" AFF,

TYP U.O.N.

NEMA L6-20,

78" AFF,

TYP U.O.N.

NEMA L6-20,

78" AFF,

TYP U.O.N.

NEMA L6-20,

78" AFF,

TYP U.O.N.

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A m e n d m e n t

/2 /2

FLEXIBLE CONNECTOR PROVIDED

BY THE CONTRACTOR

FLEXIBLE CONNECTOR FURNISHED WITH

FURNITURE PANEL

J

3'-6"

40.0

COMPRESSED AIR

QUICK CONNECT

OUTLET

1" COMPRESSED

AIR LINE

ROUTED FROM

TRENCH

1/2"BALL VALVE

DRAIN-NC

6'-0"

DUAL COMM.

OUTLET

(RJ45 CAT6)

DUPLEX GFI

RECEPTACLES

60A, 480V, 3ɸ

RECEPT.

SPARE 1" CONDUIT

STUB-UP 12" AFF &

PROVIDE

THREADED CAP

10"x10"x58" BASE

PLATE WITH 4-3/4"

DIA. ANCHOR

BOLTS

LEFT ELEVATION

3'-6"

COMPRESSED

AIR

QUICK CONNECT

OUTLET

1/2"BALL VALVE

DRAIN-NC

1" COMPRESSED

AIR LINE

ROUTED FROM

TRENCH

DUPLEX GFI

RECEPTACLES

DUAL COMM.

OUTLET

(RJ45 CAT6)

C4x7.2

10"x10"x5/8" BASE

PLATE WITH

4-3/4" DIA.

ANCHOR BOLTS

HSS 4x4x1/4"

FRONT ELEVATION

NOTES:

1. ALL RECEPTACLES ON ASPR'S SHALL

BE WEATHERPROOF.

2. 120V DUPLEX RECEPTACLES SHALL

HAVE GFI PROTECTION. DOWNSTREAM

DEVICES SHALL BE FED NON-GFI.

DUPLEX GFI

RECEPTACLES

C4x7.2

10"x10"x5/8" BASE

PLATE WITH

4-3/4" DIA.

ANCHOR BOLTS

RIGHT ELEVATION

TOP VIEW

APPLETON ACP1034

100A,3Ø, 4W RECEPTACLE

A B C D

J

NOTE:

LETTER AT HOMERUNS INDICATES CIRCUIT

DESIGNATION. SEE PLANS FOR EXACT CIRCUIT.

K

H F

E

G

MODULAR FURNITURE PANEL (PROVIDED

UNDER A SEPARATE CONTRACT)

4-11/16" X 2-1/2" DEEP SQ

OUTLET BOXES WITH

SINGLE GANG RISE COVER

PLATES & FINISHED DEVICE

PLATE

FINISHED

FLOOR

BASE INFEED MODULE FURNISHED WITH

FURNITURE PANEL.

COMMUNICATIONS SYSTEM OUTLET AND COVER

PLATE FURNISHED WITH FURNITURE PANEL.

SPACE GAP WHICH ALLOWS FLEXIBLE

CONNECTORS TO RUN BELOW PANEL.

DATA JACKS

VOICE JACK(S)

DUPLEX RECEPTACLE

BASE TRIM WITH UL APPROVED

ELECTRICAL SYSTEMS. RECEPTACLES AND

JACKS PROVIDED WITH MODULAR

FURNITURE. RECEPTACLES CIRCUITRY

PROVIDED WITH THE FURNITURE PANEL.

ELECTRICAL CIRCUITS HOMERUN.

EXPOSED CONDUITS

SUSPENDED CEILING

CONCEALED CONDUITS

1-1/4"C WITH CABLING

1/2"C

SEE THE POWER FLOOR PLANS

FOR CIRCUIT DESIGNATIONS,

GROUPING AND ARRANGEMENTS.

1.

NOTES :

BASE FEED INPUT (BFI)

A I

N I

G

RI

VFOHTLAE

W

N O

M M

O C

P R

O F

ESS I ONAL ENG

I N

E E

R

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S D

R A

W N

B Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

D

A T

E

T

IM

E S

T A

M P

IS

S

U E

D A

T E

C O

N T

R A

P R

O J E

C T

N O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

PROPERTY OF UNITED STATES GOVERNMENT, FOR OFFICIAL USE ONLY (FOUO). COPYING, DISSEMINATION, AND DISTRIBUTION TO UNAUTHORIZED INDIVIDUALS PROHIBITED.

JAMES E. BARKLEY, JR.

Lic. No. 043854

01/10/20

/2

/2

:4

:3

P

M

EP501

PHASE 3

A S

P R

D E

T A

IL

S

B A

T T

A L

IO

N

C O

M P

L E

X N

O R

F O

L K

D

IS

T R

IC

T

N O

R F

O L

K

V A

M L

IN

D A

L E

A R

A M

O S

B W

O O

D

J B

A R

K L E

Y

J A

N U

A R

Y

R T

A S

U B

M

IT

T A

L

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A m e n d m e n t

/2 /2

Sheets
EP130 - SECOND FLOOR PLAN - AREA K - POWER
EP401 - ENLARGED PLANS
EP402 - ENLARGED PLANS
EP501 - ASPR DETAILS

File details come from the government source that posted it. Updated .