719_BC_Sheet - I-007.pdf

PDF 70 KB Posted

Attached to
Battalion Complex (Amendment 8)
Solicitation number
W9123620R0001
Issued by

View the file

Other files

File Type Posted
W9123620R0001P0008 - Amendment 8.pdf PDF
18245_ - AREA T - POWER.pdf PDF
A.07.24 - W9123620R0001(Amendment 7).pdf PDF
W9123620R0001 Amendment 6.pdf PDF
719_BC-PH2_SF423.pdf PDF
719_BC-PH2_MP121.pdf PDF
719_BC -PH2-A-601.pdf PDF
719_BC-PH2_SF600(Amend5).pdf PDF
720_BC-PH3-S504.pdf PDF
719_BC-PH2_26 20 00.pdf PDF
719_BC-PH2_MP111.pdf PDF
719_BC_PH2_Sheet A-200.pdf PDF
719_BC_Sheet - I-003.pdf PDF
719_BC-PH2_SF505.pdf PDF
719_BC-PH2_MP122.pdf PDF
720_BC-PH3-CS103.pdf PDF
719_BC-PH2_MP116.pdf PDF
719_BC-PH2_SF422.pdf PDF
719_BC_Sheet - I-223.pdf PDF
05 12 00.pdf PDF
22 00 00.pdf PDF
720_BC-PH3-CU102.pdf PDF
719_BC_PH2_Sheet A-412.pdf PDF
720_BC-PH3-S215 (1).pdf PDF
719_BC_FFE_PH2_Amendment 5 sheets(Amend5).pdf PDF
719_BC-PH2_SF420.pdf PDF
719_BC-PH2 Sheet EP404.pdf PDF
26 51 00.pdf PDF
719_BC-PH2_SF425.pdf PDF
10 28 13.pdf PDF
23 65 00.pdf PDF
28 31 76.pdf PDF
719_BC_Sheet - I-008.pdf PDF
AMEND005-719_BC-PH2_FA001-FA126.pdf PDF
719_BC-PH2_03 30 00.00 10.pdf PDF
719_BC-PH2_10 21 13.pdf PDF
PH1 TWS TWR piping routing.pdf PDF
720_BC-PH3-SF600.pdf PDF
720_BC_PH3_EL119-EL123_EL502.pdf PDF
719_BC-PH2_FA001_FA111-FA114.pdf PDF
719_BC_Sheet - I-124.pdf PDF
719_BC -PH2-A- 603.pdf PDF
719_BC_PH2_Sheet A-411.pdf PDF
720_BC_PH3_FP001_FP140-FP143.pdf PDF
719_BC-PH2_SF421.pdf PDF
719_BC-PH2_SB106.pdf PDF
720_BC_PH3_A-605.pdf PDF
719_BC-PH2_MP113.pdf PDF
719_BC-PH2_11 46 01.06.pdf PDF
719_BC-PH2_S-001(Amend5).pdf PDF
Show 40 more

Latest 50 of 136 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FINISH SCHEDULE REMARKS

REFER TO SHEET I-002 AND I-003 FOR INTERIOR FINISH

LEGEND.

REFER TO SHEET I-211 THROUGH I-226 FOR WALL FINISHES

THAT INDICATES "VARIES".

REFER TO SHEET I-261 FOR INTERIOR FINISH WALL DETAILS

IN LOBBY, PAINT EXPOSED METAL DECK/CLG AND ALL DUCT

WORK, PIPING AND RELATED EQUIPMENT / CONNECTIONS

(PNT4). PAINT STRUCTURAL STEEL (PNT1). PAINT WALLS

CONTINUOUS TO CEILING (PNT3). REFER TO LOBBY

SECTIONS ON SHEET A-352-A-353 FOR MORE INFORMATION.

US Army Corps of Engineers ®

SHEET ID

US

A

RM

Y

CO

RP

S O

F

EN

G

IN

EE

RS

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

D

AT

E

TI

M

E

ST

AM

P:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

PR

O

JE

C

T N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

PROPERTY OF UNITED STATES GOVERNMENT, FOR OFFICIAL USE ONLY (FOUO). COPYING, DISSEMINATION, AND DISTRIBUTION TO UNAUTHORIZED INDIVIDUALS PROHIBITED.

4/

/2

2:

:1

PM

I-007

PHASE 2

IN

TE

R

IO

R F

IN

IS

H S

C H

ED

U

LE

B

AT

TA

LI

O N

C O

M

PL

EX

N

O R

FO

LK

D

IS

TR

IC

T N

O R

FO

LK

, V A

R . L

IN

D

Q U

IS

T

M . J

O H

N

SO

N

D . G

EB

LE

R

D . G

EB

LE

R

JA

N

U

AR

Y

R

TA

S U

BM

IT

TA

L

FINISH SCHEDULE

ROOM

NO ROOM NAME

WALL FINISH CHAIR RAIL FINISH WAINSCOT FINISH BASE FINISH FLOOR

FINISH

CEILING

REMARKSNORTH EAST SOUTH WEST NORTH EAST SOUTH WEST NORTH EAST SOUTH WEST NORTH EAST SOUTH WEST FINISH

2202 ELEC PNT3 PNT3 PNT3 PNT3 RB1 RB1 RB1 RB1 LVT2

2203 TR PNT3 PNT3 PNT3 PNT3 RB1 RB1 RB1 RB1 SDT1

2204 VESTIBULE PNT3 PNT3 PNT3 PNT3 WB1 WB1 WB1 WB1 CPT7 ACT1

2205 LARGE VTC

CONFERENCE

ROOM

PNT3 PNT3 VWC5 PNT3 WSCT1 WSCT1 - WSCT1 WB2 CPT7 ACT1/AC

T4

2205A UTILITY PNT3 PNT3 PNT3 PNT3 RB1 RB1 RB1 RB1 LVT2

2206 A/V ROOM PNT3 PNT3 PNT3 PNT3 RB1 RB1 RB1 RB1 CPT7 ACT1

2207 COFFEE PNT3 PNT3 PNT3 PNT3 WB1 WB1 WB1 WB1 LVT1 ACT1

2208 WAITING &

RECEPTION

VWC4 PNT3 PNT3 PNT3 WB1 WB1 WB1 WB1 CPT7 ACT1

2209 COFFEE PNT3 PNT3 PNT3 PNT3 WB1 WB1 WB1 WB1 LVT1 ACT1

2210 TOILET WP1 WP1 WP1 WP2 - - - - PRC1 GYP. 3

2211 CORRIDOR PNT3 PNT3 PNT3 PNT3 WB1 WB1 WB1 WB1 CPT7 ACT1

2212 OFFICE PNT4 PNT3 PNT3 PNT3 WB1 WB1 WB1 WB1 CPT7 ACT1

2213 OFFICE PNT4 PNT3 PNT3 PNT3 WB1 WB1 WB1 WB1 CPT7 ACT1

2214 OFFICE PNT3 PNT3 PNT4 PNT3 WB1 WB1 WB1 WB1 CPT7 ACT1

2215 CONF. PNT4 VWC5 PNT4 PNT4 WSCT1 - WSCT1 WSCT1 WB2 CPT7 ACT1

2216 WORKROOM PNT3 PNT3 PNT3 PNT3 WB1 WB1 WB1 WB1 CPT7 ACT1

2217 OFFICE PNT3 PNT3 PNT3 PNT4 WB1 WB1 WB1 WB1 CPT7 ACT1

2218 PREP ROOM PNT3 PNT3 PNT3 PNT5 RB1 RB1 RB1 RB1 CPT5 ACT1

2219 NOS DATA

CENTER

PNT3 PNT3 PNT3 PNT3 RB1 RB1 RB1 RB1 LVT2 ACT1

2220 NOS

WORKSHOP

PNT3 PNT3 PNT3 PNT5 RB1 RB1 RB1 RB1 LVT2 ACT1

2221 MECH PNT3 PNT3 PNT3 PNT3 RB1 RB1 RB1 RB1 LVT2

2222 TR PNT3 PNT3 PNT3 PNT3 RB1 RB1 RB1 RB1 SDT1

2223 ELEC PNT3 PNT3 PNT3 PNT3 RB1 RB1 RB1 RB1 LVT2

2225 OPS OPEN

OFFICE

PNT3 PNT5 PNT3 VARIES RB1 RB1 RB1 RB1 CP5 ACT1

2226 CONFERENCE

ROOM

PNT6 PNT4 PNT6 PNT6 WCR - WCR WCR RB1 RB1 RB1 RB1 CPT5 ACT1

2227 S & S OPEN

OFFICE

PNT3 PNT5 PNT3 PNT3 RB1 RB1 RB1 RB1 CPT5 ACT1

2301 MEN WP1 WP1 WP1 VARIES - - - - PRC1 GYP. 3

2302 WOMEN WP1 WP1 WP1 VARIES - - - - PRC1 GYP. 3

2303 JAN. PNT3 PNT3 PNT3 PNT3 RB1 RB1 RB1 RB1 LVT2

2304 TR PNT3 PNT3 PNT3 PNT3 RB1 RB1 RB1 RB1 SDT1

2305 ELEC PNT3 PNT3 PNT3 PNT3 RB1 RB1 RB1 RB1 LVT2

2306 CONFERENCE

ROOM

PNT4 PNT6 PNT6 PNT6 - WG1 WG1 WG1 RB1 RB1 RB1 RB1 CPT8

2307 STORAGE PNT3 PNT3 PNT3 PNT3 RB1 RB1 RB1 RB1 CTP5

2308 SECURITY OPEN

OFFICE

PNT3 PNT3 PNT3 PNT3 RB1 RB1 RB1 RB1 CPT5 ACT1

2309 OFFICE PNT3 PNT3 PNT6 PNT3 RB1 RB1 RB1 RB1 CPT5 ACT1

2310 OFFICE PNT6 PNT3 PNT3 PNT3 RB1 RB1 RB1 RB1 CPT5 ACT1

2311 OFFICE PNT6 PNT3 PNT3 PNT3 RB1 RB1 RB1 RB1 CPT5 ACT1

2313 CARDIO

MEZZANINE

PNT3 PNT5 PNT3 PNT3 RB1 RB1 RB1 RB1 RTF1

2314 YOGA ROOM PNT6 PNT6 PNT6 PNT6 RB1 RB1 RB1 RB1 LVT1 ACT1

2315 MECHANICAL

PLATFORM

PNT4 PNT4 PNT4 PNT4 RB1 RB1 RB1 RB1 SC

2326 MECH MEZZ PNT4 PNT4 PNT4 PNT4 RB1 RB1 RB1 RB1 SC

2327 MECH MEZZ SC

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AM

E N D

M

EN

T

-2 3-

2 0

Sheets
I-003 - INTERIOR FINISH LEGEND
I-007 - INTERIOR FINISH SCHEDULE
I-008 - INTERIOR FINISH SCHEDULE
I-113 - FIRST FLOOR PATTERN PLAN - AREA C
I-124 - SECOND FLOOR PATTERN PLAN - AREA D
I-223 - SECOND FLOOR WALL FINISH PLAN - AREA C

File details come from the government source that posted it. Updated .