Sheet 6.pdf

PDF 29 MB Posted

Attached to
Sewer Line Rehabilitation Homestead Run
Solicitation number
W911WN10B0008
Issued by

About this file

Contract Dwg

View the file

Other files

File Type Posted
W911WN10C0014 Mod P00001.pdf PDF
Bid results for 10B0008.doc DOC document
Amendment 0002 Summary of Changes.pdf PDF
33 01 99.pdf PDF
01 57 20.00 10.pdf PDF
Bidder Questions and Answers.doc DOC document
MSSMA Manhole Rehabilitation Schedule Am 2.pdf PDF
01 22 00.00 10.pdf PDF
PA Programmatic General Permit —
MSSMA Manhole Schedule.pdf PDF
W911WN10B0008 Amendment 0001.pdf PDF
01 10 00.pdf PDF
01 35 26.pdf PDF
01 50 10.pdf PDF
Pre Bid Attendance Register.pdf PDF
Sheet 8.pdf PDF
Schedule Sheet 1 .pdf PDF
Sheet 10.pdf PDF
Sheet 1.pdf PDF
Cover 1 .pdf PDF
Sheet 2.pdf PDF
Sheet 5.pdf PDF
Sheet 7.pdf PDF
Sheet 4.pdf PDF
Sheet 3.pdf PDF
Sheet 9.pdf PDF
Technical Specifications.pdf PDF
W911WN10B0008.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Chester Engineers Airside Business Park 260 Airside Dr. Moon Twp., PA 15108-2793

(412) 890-6600 FAX (412) 809-6611

www.chester-engineers.com

Drawing Sheet Rev

FILE:

PLOTTED: 08-6405-MC-A-05

PROJECT:

0 25 5012.5 Feet

I

G:\2009\Munhall\USACE\Mapbook\Mapbook_v6.mxd

Sewer locations are approximate.

Pipe widths are not drawn to scale.

Please field verify manhole locations.

6 of 101 inch = 50 feet

US ARMY CORPS OF ENGINEERS

PITTSBURGH DISTRICT

NON FEDERAL SPONSOR

MUNICIPALITY OF MUNHALL

ALLEGHENY COUNTY, PA

MSSMA HOMESTEAD RUN LINING PROJECT

Scheduled Repair Items !( Manhole, to be rehabilitated

$1 Tap Break-In, to be cut Full length lining

Lateral, to be reconnected

REHABILITATE

EXISTING MANHOLE 1025

INSTALL NEW WATERTIGHT FRAME AND COVER

SEAL EXTERIOR

DEPTH: 6.17 FT

REHABILITATE

EXISTING MANHOLE 1024

INSTALL LIFTMATE HINGE SYSTEM

SEAL EXTERIOR

DEPTH: 7.5 FT

REHABILITATE

EXISTING MANHOLE 207

INSTALL NEW WATERTIGHT FRAME AND COVER

SEAL INVERT

DEPTH: 7.5 FT

REHABILITATE

EXISTING MANHOLE 104

INSTALL NEW WATERTIGHT FRAME AND COVER

SEAL INVERT

DEPTH: 7.5 FT

REHABILITATE

EXISTING MANHOLE 103

INSTALL NEW WATERTIGHT FRAME AND COVER

SEAL EXTERIOR

DEPTH:8.06 FT

REHABILITATE

EXISTING MANHOLE 1026C

INSTALL NEW FRAME AND COVER

DEPTH: 4.11 FT

REHABILITATE

EXISTING MANHOLE 105

INSTALL NEW WATERTIGHT FRAME AND COVER

SEAL BRICK INTERIOR

SEAL EXTERIOR

DEPTH: 7.58 FT

REHABILITATE

EXISTING MANHOLE 106

INSTALL NEW WATERTIGHT FRAME AND COVER

SEAL BRICK INTERIOR

SEAL EXTERIOR

DEPTH: 6.13 FT

REHABILITATE

EXISTING MANHOLE 1085A

INSTALL NEW WATERTIGHT FRAME AND COVER

SEAL BRICK INTERIOR

SEAL EXTERIOR

DEPTH: 6.75 FT

REHABILITATE

EXISTING MANHOLE 1085

INSTALL NEW FRAME AND COVER

SEAL BRICK INTERIOR

DEPTH: 6.92 FT

1 SQ YD CONCRETE SIDEWALK RESTORATION

REHABILITATE

EXISTING MANHOLE 1086

INSTALL NEW WATERTIGHT FRAME AND COVER

SEAL INVERT

DEPTH: 12.44 FT

REHABILITATEEXISTING MANHOLE 96INSTALL NEW WATERTIGHT FRAME AND COVER

SEAL INVERTDEPTH: 9.49

REHABILITATE

EXISTING MANHOLE 97A

INSTALL NEW WATERTIGHT FRAME AND COVER

SEAL INVERT

DEPTH: 10FT

REHABILITATE

EXISTING MANHOLE 97

INSTALL NEW FRAME AND COVER

DEPTH:16.5 FT

1 SQ YD ASPHALT STREET RESTORATION

REHABILITATE

EXISTING MANHOLE 98

INSTALL NEW WATERTIGHT FRAME AND COVER

SEAL EXTERIOR

DEPTH: 8.83 FT

20' Construction Work Limit

Public RoW

Temporary Easement

0.027 Acres

20' Width

20' Construction Work Limit

1226 1224

1301 1275

1266 1262

1368 1362 1364 1358 1356 1354

1350 1346 1342 1338

1085A

1026C

SH

ER

MA

N

AV

E

POPPY WAYFREIDEL ST

W MARIGOLD ST

W LARKSPUR ST

RAVINE ST

COAL ST

SHERMAN AVE

180-J-108 180-J-114180-J-112

180-E-160

180-J-116

180-J-120

180-J-105180-J-102

180-J-103

180-N-19

180-J-121

180-J-100

180-J-123

180-J-126

180-J-104 180-J-106

179-N-25

180-J-134

180-J-122

180-J-118 180-J-110

180-J-101

180-J-132

180-J-129

180-E-158

180-J-136 180-E-162

24'' x 345'

18'' x 103'

24'' x 331'

24'' x 42'

Legend !( Manhole, no rehabilitation required

Sewer Line, no rehabilitation required Drainage Edge of Pavement Munhall Boundary

Erosion and Sediment Control Public RoW Work Limit Temporary Laydown Area Temporary Access Road Parcel Building Footprint

Flow DirectionClearing and Grubbing, as needed Construction Set

Base Bid Additive Item A Additive Item B

PROJECT EXTENT

12/15/09 FINAL

File details come from the government source that posted it. Updated .