Sheet 1.pdf

PDF 29 MB Posted

Attached to
Sewer Line Rehabilitation Homestead Run
Solicitation number
W911WN10B0008
Issued by

About this file

contract drawing for 10B0008

View the file

Other files

File Type Posted
W911WN10C0014 Mod P00001.pdf PDF
Bid results for 10B0008.doc DOC document
Amendment 0002 Summary of Changes.pdf PDF
33 01 99.pdf PDF
01 57 20.00 10.pdf PDF
Bidder Questions and Answers.doc DOC document
MSSMA Manhole Rehabilitation Schedule Am 2.pdf PDF
01 22 00.00 10.pdf PDF
PA Programmatic General Permit —
MSSMA Manhole Schedule.pdf PDF
W911WN10B0008 Amendment 0001.pdf PDF
01 10 00.pdf PDF
01 35 26.pdf PDF
01 50 10.pdf PDF
Pre Bid Attendance Register.pdf PDF
Sheet 8.pdf PDF
Schedule Sheet 1 .pdf PDF
Sheet 10.pdf PDF
Cover 1 .pdf PDF
Sheet 6.pdf PDF
Sheet 2.pdf PDF
Sheet 5.pdf PDF
Sheet 7.pdf PDF
Sheet 4.pdf PDF
Sheet 3.pdf PDF
Sheet 9.pdf PDF
Technical Specifications.pdf PDF
W911WN10B0008.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Chester Engineers Airside Business Park 260 Airside Dr. Moon Twp., PA 15108-2793

(412) 890-6600 FAX (412) 809-6611

www.chester-engineers.com

Drawing Sheet Rev

FILE:

PLOTTED: 08-6405-MC-A-05

PROJECT:

0 25 5012.5 Feet

I

G:\2009\Munhall\USACE\Mapbook\Mapbook_v6.mxd

Sewer locations are approximate.

Pipe widths are not drawn to scale.

Please field verify manhole locations.

1 of 101 inch = 50 feet

US ARMY CORPS OF ENGINEERS

PITTSBURGH DISTRICT

NON FEDERAL SPONSOR

MUNICIPALITY OF MUNHALL

ALLEGHENY COUNTY, PA

MSSMA HOMESTEAD RUN LINING PROJECT

Scheduled Repair Items !( Manhole, to be rehabilitated

$1 Tap Break-In, to be cut Full length lining

Lateral, to be reconnected

REHABILITATE

EXISTING MANHOLE 391

INSTALL NEW WATERTIGHT FRAME AND COVER

SEAL BRICK INTERIOR

SEAL INVERT

DEPTH: 8.25 FT

REHABILITATE

EXISTING MANHOLE 383

INSTALL NEW WATERTIGHT FRAME AND COVER

SEAL BRICK INTERIOR

SEAL INVERT

DEPTH: 7.5 FT

REHABILITATE

EXISTING MANHOLE 374

INSTALL NEW WATERTIGHT FRAME AND COVER

SEAL BRICK INTERIOR

SEAL INVERT

DEPTH: 6.3 FT

REHABILITATE

EXISTING MANHOLE 373

INSTALL NEW WATERTIGHT FRAME AND COVER

SEAL INVERT

DEPTH: 10.23 FT

REHABILITATE

EXISTING MANHOLE 397

INSTALL NEW FRAME AND COVER

SEAL BRICK INTERIOR

DEPTH: 5.2 FT

1 SQ YD ASPHALT RESTORATION

REHABILITATE

EXISTING MANHOLE 396

INSTALL NEW FRAME AND COVER

SEAL BRICK INTERIOR

DEPTH: 6.06 FT

1 SQ YD ASPHALT RESTORATION

REHABILITATE

EXISTING MANHOLE 395

INSTALL NEW FRAME AND COVER

SEAL BRICK INTERIOR

DEPTH: 17 FT

1 SQ YD ASPHALT RESTORATION

Begin Additive Item B

Public RoW

50' Construction Work Limit

20' Construction Work Limit Do not exceed Public RoW

182-E-140

182-E-230

133-H-188

182-E-234

182-E-138

133-H-198

182-E-232

133-H-207

133-H-196

182-E-236

182-E-148

182-E-142

133-H-200 182-E-238

182-E-146

182-A-304

182-E-144

3617 4346

391397

18'' x 151' 18'' x 243'

18'' x 319'

18'' x 367'

18'' x 426'

SHADY AVE

RE

D

OA

K

LN

SU

PE

RI

OR

ST

SU

PE

RI

OR

ST

CHESTNUT LN

HARVEY ST

ACORN WAY

TIMBERWOOD DR

HARVEY

ST

VALEWOOD DR

WOODHAVEN DR

WOODHILL DR

Legend !( Manhole, no rehabilitation required

Sewer Line, no rehabilitation required Drainage Edge of Pavement Munhall Boundary

Erosion and Sediment Control Public RoW Work Limit Temporary Laydown Area Temporary Access Road Parcel Building Footprint

Flow DirectionClearing and Grubbing, as needed Construction Set

Base Bid Additive Item A Additive Item B

PROJECT EXTENT

12/15/09 FINAL

File details come from the government source that posted it. Updated .