Sheet 3.pdf

PDF 29 MB Posted

Attached to
Sewer Line Rehabilitation Homestead Run
Solicitation number
W911WN10B0008
Issued by

About this file

Contract Dwg

View the file

Other files

File Type Posted
W911WN10C0014 Mod P00001.pdf PDF
Bid results for 10B0008.doc DOC document
Amendment 0002 Summary of Changes.pdf PDF
33 01 99.pdf PDF
01 57 20.00 10.pdf PDF
Bidder Questions and Answers.doc DOC document
MSSMA Manhole Rehabilitation Schedule Am 2.pdf PDF
01 22 00.00 10.pdf PDF
PA Programmatic General Permit —
MSSMA Manhole Schedule.pdf PDF
W911WN10B0008 Amendment 0001.pdf PDF
01 10 00.pdf PDF
01 35 26.pdf PDF
01 50 10.pdf PDF
Pre Bid Attendance Register.pdf PDF
Sheet 8.pdf PDF
Schedule Sheet 1 .pdf PDF
Sheet 10.pdf PDF
Sheet 1.pdf PDF
Cover 1 .pdf PDF
Sheet 6.pdf PDF
Sheet 2.pdf PDF
Sheet 5.pdf PDF
Sheet 7.pdf PDF
Sheet 4.pdf PDF
Sheet 9.pdf PDF
Technical Specifications.pdf PDF
W911WN10B0008.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Chester Engineers Airside Business Park 260 Airside Dr. Moon Twp., PA 15108-2793

(412) 890-6600 FAX (412) 809-6611

www.chester-engineers.com

Drawing Sheet Rev

FILE:

PLOTTED: 08-6405-MC-A-05

PROJECT:

0 25 5012.5 Feet

I

G:\2009\Munhall\USACE\Mapbook\Mapbook_v6.mxd

Sewer locations are approximate.

Pipe widths are not drawn to scale.

Please field verify manhole locations.

3 of 101 inch = 50 feet

US ARMY CORPS OF ENGINEERS

PITTSBURGH DISTRICT

NON FEDERAL SPONSOR

MUNICIPALITY OF MUNHALL

ALLEGHENY COUNTY, PA

MSSMA HOMESTEAD RUN LINING PROJECT

Scheduled Repair Items !( Manhole, to be rehabilitated

$1 Tap Break-In, to be cut Full length lining

Lateral, to be reconnected

REHABILITATE

EXISTING MANHOLE 362

INSTALL NEW FRAME AND COVER

SEAL INVERT

DEPTH: 22 FT

REHABILITATE

EXISTING MANHOLE 361

INSTALL NEW WATERTIGHT FRAME AND COVER

SEAL BRICK INTERIOR

DEPTH: 8.6 FT

REHABILITATE

EXISTING MANHOLE 359A

INSTALL LIFTMATE HINGE SYSTEM

SEAL BRICK INTERIOR

SEAL EXTERIOR

DEPTH: 15.92 FT

REHABILITATE

EXISTING MANHOLE 951

INSTALL NEW WATERTIGHT FRAME AND COVER

SEAL INVERT

DEPTH: 6.3 FT

REHABILITATE

EXISTING MANHOLE 952

INSTALL NEW WATERTIGHT FRAME AND COVER

SEAL BRICK INTERIOR

SEAL INVERT

DEPTH: 7.92 FT

REHABILITATE

EXISTING MANHOLE 950

INSTALL NEW WATERTIGHT FRAME AND COVER

DEPTH: 16.26 FT

REHABILITATE

EXISTING MANHOLE 219

INSTALL NEW WATERTIGHT FRAME AND COVER

SEAL INVERT

DEPTH: 10 FT

REHABILITATE

EXISTING MANHOLE 953

INSTALL NEW WATERTIGHT FRAME AND COVER

SEAL INVERT

DEPTH: 11.4 FT

REHABILITATE

EXISTING MANHOLE 954

INSTALL NEW WATERTIGHT FRAME AND COVER

SEAL BRICK INTERIOR

DEPTH: 14.83 FT

REHABILITATE

EXISTING MANHOLE 954A

INSTALL NEW WATERTIGHT FRAME AND COVER

DEPTH: 14.08 FT

REHABILITATE

EXISTING MANHOLE 217

SEAL BRICK INTERIOR

DEPTH: 11.08 FT

REBALITATE

EXISTING MANHOLE 1005

INSTALL NEW WATERTIGHT FRAME AND COVER

SEAL INVERT

DEPTH: 30 FT

Construction Work Limit Access Road

Public RoW

Public RoW

20' Construction Work Limit

Temporary Easement Access Road #2

0.77 Acres

20' Width

End Additive Item B Begin Additive Item A

20' Construction Work Limit

Do not reopen Laterals on segment 217-216

359A

954A 362 219

953951

3301 3231

3313 3309

181-P-40

181-K-30

181-P-45

182-A-304

181-K-57 181-K-55

181-K-60

181-K-70

181-K-40

181-F-100

181-F-150

COAL

RD

HOMESTEAD DUQUESNE RD

E JAMES ST

PATTON AVE

BELLW

OOD RD

VALEWOOD DR

24'' x 40'

24'' x 47'

24'' x237'

24'' x 96'

24'' x 584'

24'' x 156'

24'' x 171'

24'' x 179'

24'' x 231'

24'' x 242'

24'' x 93'

24'' x 250'

Legend !( Manhole, no rehabilitation required

Sewer Line, no rehabilitation required Drainage Edge of Pavement Munhall Boundary

Erosion and Sediment Control Public RoW Work Limit Temporary Laydown Area Temporary Access Road Parcel Building Footprint

Flow DirectionClearing and Grubbing, as needed Construction Set

Base Bid Additive Item A Additive Item B

PROJECT EXTENT

12/15/09 FINAL

File details come from the government source that posted it. Updated .