Sheet 2.pdf
PDF 29 MB Posted
- Attached to
- Sewer Line Rehabilitation Homestead Run
- Solicitation number
- W911WN10B0008
About this file
Contract Drawing
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W911WN10C0014 Mod P00001.pdf | ||
| Bid results for 10B0008.doc | DOC document | |
| Amendment 0002 Summary of Changes.pdf | ||
| 33 01 99.pdf | ||
| 01 57 20.00 10.pdf | ||
| Bidder Questions and Answers.doc | DOC document | |
| MSSMA Manhole Rehabilitation Schedule Am 2.pdf | ||
| 01 22 00.00 10.pdf | ||
| PA Programmatic General Permit | — | |
| MSSMA Manhole Schedule.pdf | ||
| W911WN10B0008 Amendment 0001.pdf | ||
| 01 10 00.pdf | ||
| 01 35 26.pdf | ||
| 01 50 10.pdf | ||
| Pre Bid Attendance Register.pdf | ||
| Sheet 8.pdf | ||
| Schedule Sheet 1 .pdf | ||
| Sheet 10.pdf | ||
| Sheet 1.pdf | ||
| Cover 1 .pdf | ||
| Sheet 6.pdf | ||
| Sheet 5.pdf | ||
| Sheet 7.pdf | ||
| Sheet 4.pdf | ||
| Sheet 3.pdf | ||
| Sheet 9.pdf | ||
| Technical Specifications.pdf | ||
| W911WN10B0008.pdf |
Show all 28
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Chester Engineers Airside Business Park 260 Airside Dr. Moon Twp., PA 15108-2793
(412) 890-6600 FAX (412) 809-6611
www.chester-engineers.com
Drawing Sheet Rev
FILE:
PLOTTED: 08-6405-MC-A-05
PROJECT:
0 25 5012.5 Feet
I
G:\2009\Munhall\USACE\Mapbook\Mapbook_v6.mxd
Sewer locations are approximate.
Pipe widths are not drawn to scale.
Please field verify manhole locations.
2 of 101 inch = 50 feet
US ARMY CORPS OF ENGINEERS
PITTSBURGH DISTRICT
NON FEDERAL SPONSOR
MUNICIPALITY OF MUNHALL
ALLEGHENY COUNTY, PA
MSSMA HOMESTEAD RUN LINING PROJECT
Scheduled Repair Items !( Manhole, to be rehabilitated
$1 Tap Break-In, to be cut Full length lining
Lateral, to be reconnected
REHABILITATE
EXISTING MANHOLE 391
INSTALL NEW WATERTIGHT FRAME AND COVER
SEAL BRICK INTERIOR
SEAL INVERT
DEPTH: 8.25 FT
REHABILITATE
EXISTING MANHOLE 383
INSTALL NEW WATERTIGHT FRAME AND COVER
SEAL BRICK INTERIOR
SEAL INVERT
DEPTH: 7.5 FT
REHABILITATE
EXISTING MANHOLE 374
INSTALL NEW WATERTIGHT FRAME AND COVER
SEAL BRICK INTERIOR
SEAL INVERT
DEPTH: 6.3 FT
REHABILITATE
EXISTING MANHOLE 373
INSTALL NEW WATERTIGHT FRAME AND COVER
SEAL INVERT
DEPTH: 10.23 FT
REHABILITATE
EXISTING MANHOLE 363
INSTALL NEW WATERTIGHT FRAME AND COVER
SEAL INVERT
DEPTH: 10 FT
REHABILITATE
EXISTING MANHOLE 362
INSTALL NEW FRAME AND COVER
SEAL INVERT
DEPTH: 22 FT
REHABILITATE
EXISTING MANHOLE 361
INSTALL NEW WATERTIGHT FRAME AND COVER
SEAL BRICK INTERIOR
DEPTH: 8.6 FT
REHABILITATE
EXISTING MANHOLE 359A
INSTALL LIFTMATE HINGE SYSTEM
SEAL BRICK INTERIOR
SEAL EXTERIOR
DEPTH: 15.92 FT
50' Construction Work Limit
50' Construction Work Limit
Construction Work Limit Access Road
Public RoW
Laydown Area #2
Temporary Easement
Access Road #2
0.77 Acres
20' Width
End Additive Item B
Begin Additive Item A
24'' x 156' 24'' x 96'
24'' x 239'
18'' x 367'
24'' x 369'
24'' x 584'
181-P-40
181-K-30
181-P-45
182-A-304
TIMBERWOOD DR
VICTORIA
ST
E EUGENE AVE
HOMESTEAD DUQUESNE RD
VALEWOOD DR
SCHOOL ST
PA
TTO
N
AV
E
WOODHAVEN
DR
BE
LL
WO
OD
RD
WOODHILL DR
Legend !( Manhole, no rehabilitation required
Sewer Line, no rehabilitation required Drainage Edge of Pavement Munhall Boundary
Erosion and Sediment Control Public RoW Work Limit Temporary Laydown Area Temporary Access Road Parcel Building Footprint
Flow DirectionClearing and Grubbing, as needed Construction Set
Base Bid Additive Item A Additive Item B
PROJECT EXTENT
12/15/09 FINAL