Attachment_13_W911SA17R3000_Government_Responses_to_Questions.xlsx

XLSX spreadsheet 41 KB Posted

Attached to
Logistics Readiness Support Services for 63rd RSC in CA and NV
Solicitation number
W911SA-17-R-3000
Issued by

About this file

This document contains questions and answers related to a solicitation for logistics readiness support services for the 63rd Regional Support Command in California and Nevada. The solicitation seeks firm fixed-price proposals to provide maintenance and repair services at various equipment concentration sites and Army maintenance support activities. Services include equipment operation, maintenance management, transportation, and contractor management reporting. Proposals are due by January 30, 2018 and the period of performance is one base year with four option years. The Department of the Army Materiel Command Mission and Installation Contracting Command at Fort McCoy is the contracting agency. The incumbent contractor is not identified. Pricing must be included for all costs including equipment operation qualifications and employee attrition rates. One project manager is required overall rather than at each individual site.

Attachment 13 W911SA17R3000 Government Responses to Questions

View the file

Other files

File Type Posted
W911SA-17-R-3000_0010_Amendment_10.docx DOCX document
Attachment_7_Wage_Determinations_Full_length_20180117.docx DOCX document
W911SA-17-R-3000_0009_Amendment_9.docx DOCX document
Attachment_7_Wage_Determinations_Full_length_20180103.docx DOCX document
Attachment_16_W911SA17R3000_Government_Responses_to_Additional_Questions_updated_20171211.xlsx XLSX spreadsheet
W911SA-17-R-3000_0008_Conformed_Solicitation.docx DOCX document
W911SA-17-R-3000_0008_Amendment_8.docx DOCX document
Attachment_2_Price_Schedule_63d_RSC_Logistical_Support_CA_Region.xlsx XLSX spreadsheet
Attachment_16_W911SA17R3000_Government_Responses_to_Additional_Questions.xlsx XLSX spreadsheet
W911SA-17-R-3000_0007_Conformed_Copy_Solicitation.docx DOCX document
W911SA-17-R-3000_0007_Amendment_7.docx DOCX document
W911SA-17-R-3000_0006_Amendment_6.docx DOCX document
W911SA-17-R-3000_0006_Conformed_Solicitation.docx DOCX document
Attachment_12_Density_and_Workload_CA_Region_(002).pdf PDF
Attachment_7_Wage_Determinations_Full_length_20171204.docx DOCX document
Attachment_11_CA.pdf PDF
Attachment_12_Density_and_Workload_CA_Region.pdf PDF
Attachment_6_Mission-Essential-Contractor-Services-Jul-2017.docx DOCX document
Attachment_3_PRS_DOL_Maintenance_20170815.docx DOCX document
W911SA-17-R-3000-0005_Amendment_5.docx DOCX document
Attachment_4_Deliverables_CA_Region.docx DOCX document
Attachment_2_Price_Schedule_63d_RSC_Logistical_Support_CA_Region.xlsx XLSX spreadsheet
W911SA-17-R-3000-0005_Conformed_Copy_of_Solicitation.docx DOCX document
Attachment_9_Worksite_Locations_CA_Region.pdf PDF
Attachment_15_REVISED_Newest_Ft._Hunter_Liggett_CA_Signed_CBA_Final.pdf PDF
W911SA-17-R-3000-0004_Amendment_4.docx DOCX document
W911SA-17-R-3000-00003_Amendment_3.docx DOCX document
W911SA-17-R-3000-00002_Amendment_2.docx DOCX document
W911SA-17-R-3000-00001_Amendment_1.docx DOCX document
Attachment_3_PRS_DOL_Maintenance_20170815.docx DOCX document
Attachment_1_AT-OPSEC_63d_RSC_Logistical_Support_CA_Region.pdf PDF
Attachment_12_Density_and_Workload_CA_Region_Revised_20170621.pdf PDF
Attachment_8_Contracted_Employees_SHARP_Info_CA_Region.pdf PDF
Attachment_7_Wage_Determinations_Full_length_20170911.docx DOCX document
Attachment_9_Worksite_Locations_CA_Region_Revised_20170623.pdf PDF
Attachment_15_CBA_Fort_Hunter_Liggett_CA_Region.pdf PDF
Attachment_10_Equipment_California_Region.pdf PDF
Attachment_5_Past_performance_Attachment_Samples.docx DOCX document
Attachment_4_Deliverables_CA_Region.docx DOCX document
Attachment_2_Price_Schedule_63d_RSC_Logistical_Support_CA_Region.xlsx XLSX spreadsheet
W911SA-17-R-3000_SOLICITATION.docx DOCX document
Attachment_6_Mission-Essential-Contractor-Services-Jul-2017.docx DOCX document
Attachment_11_63rd_RSC_DOL_Equipment_Time_Standards_CA..pdf PDF
Attachment_14_CBA_Barstow_CA_Region.pdf PDF
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

63rd RSC - CA Region

Q&A Template -- 63rd Regional Support Command (RSC) -- CALIFORNIA REGION (W911SA-17-R-3000)
Question #RFP ReferencePageQUESTIONGovernment Response
1PWS 1.6.8is it possible for us to have the necessary security arrangements in place prior to contract award, rather than at proposal submission?Please see the requirements in PWS 1.6.8. These will not be changed
2L&MIt is not clear if Resumes are required to be submitted for the Project Managers for all sites and other positions as identified in the Instructions. If this is the case that Resumes are require to be submitted then us along with a number of other SDVOSB are way behind the curve tracking down the number of highly qualified people that meet the very specific qualifications called out for in the solicitation and now have less than 30 days to do so.There will be one Project Manager for this soliciation. All sites will have a supervisor responsible for them. Subfactor 1(d) in Addendums to 52.212-1 and 52.212-2 were revised
3L.-1.1; L-3.2.1; L-3.2.3; L-3.2.10L-3.2.1 states that "Offerors shall submit the number of copies listed in paragraph L-3.2.3, for their proposal." L-3.2.3 states that "Each part of the proposal shall be separately bound." It futher states that "In addition to submitting hard copies of the proposals, digital copies shall be provided on CD-ROM disk (see paragraph L.3.2.10)." L.3.2.10 states that " Digital copies shall be provided on CD-ROM disk in Microsoft Word, Adobe PDF, and/or Excel."Is the Government requiring offerors to submit their proposals electronically through the AMRDEC Safe Access File Exchange or in hard copy or by both means?Only submit proposals electronically through AMR DEC Safe Access File Exchange. Revised L.3.2.3 to remove hard copy wording
4L-4.4How many past performance citations that are recent and relevant can be submitted? Since only up to 5 questionaires are allowed, we are assuming that only up to 5 past performance citations can be submitted in the specific relevant contract format (Attachment 5, Enclosure/Attachment 2). Is this correct??Yes, 5 can be submitted IAW L-4.4
5PWS 5.12 Maintenance MangementIs SAMS-E also used in addition to FLMS and GCSS-A?GCSS is the STAMIS system in use for maintenance operations. SAMS-E is no longer used by the Army.
6GeneralDo mechanics provide their own tool box, or will the Government provide them?Contractors will be responsible for providing tools kits that are equivalent to the Master Mechanic tool set. PWS 4.1 was updated.
7subfactor 1dWould the Government prefer to see resumes of potential candidates, or would the Government prefer descriptions of said individual candidates and their qualifications as they pertain to the requirements? If resumes are preferred, the 15 page limit would be insufficient. Can the page limit be increased?As stated in 1(d), "Offeror shall provide the following qualifications for any proposed Project Managers:" Resumes would be the prefered method. The page limit will not be increased.
81.8.5.1Does the requirement for a PM designated for each site apply to each site location designated in Attachment 9One Project Manager Required. PWS 1.8.5.1 has been updated. Reference 1(d) of the Addendum to 52.212-1 and 52.212-2.
9Attachment 9 and 12Attachment 9 has Port Hueneme listed as AMSA 13, but there is no data or listing for Port Hueneme in Attachment 12. Is there something missing?Attachments are correct. AMSA 13 is correctly listed on Attachment 9, and there is data for AMSA 13 on Attachment 12.
10Attachment 9 and 12In Attachment 9, Vallejo is listed as BMA 1, but in Attachment 12, it is labeled AMSA 13. Can this be corrected?The Vallejo Facility is AMSA 85, BMA 1. AMSA 13 is the Port Hueneme Location and the address will be updated in Attachment 12.
115.14.1There is a local SOP for Equipment Storage Branch of Equipment Concentration Sites mentioned in this paragraph. Can the Government provide a copy of this SOP?Changed PWS 5.14.1 to reflect each local SOP follows regulatory guidance, but changes with mission requirements and is specific to each location.
12Surge CLINS: These CLINs represent a 10% surge increase and the descriptions are the same. What is the Government referring to for the 10% increase? Can you clarify the intent of the CLINs since the pricing attachment does not provide instruction on how to complete?The surge CLINs each account for a 10% increase in total workload. The Price Schedule automatically calculates the pricing for these CLIN's by multiplying the workload CLIN by 10%. The 10% SURGE INCREASE CLINs are locked for editing on the bid schedule and are formula driven.

Example; if the MAX AMOUNT proposed on the SF 1449 for CLIN 0001, MAINTENANCE-ECS XYZ is $10,000.00 then CLIN 0002, ECS XYZ-10% SURGE INCREASE MAX AMOUNT would be $1,000.00. If CLIN 0003 also states ECS XYZ-10% SURGE INCREASE the MAX AMOUNT would also be $1,000.00 as it is 10% of the MAX AMOUNT proposed for CLIN 0001, MAINTENANCE-ECS XYZ.

The purpose of the 10% SURGE INCREASE CLINs is to allow the 63rd RSC DOL the ability to increase workload at different worksites based on possible future increases to their Mission.

As the type of possible increases to the 63rd RSC DOL's Mission at the different worksites is not known at this time the 10% SURGE INCREASE CLINs will be negotiated with the awardee based on the prices poposed on Attachment 2 Price Schedule 63d RSC Logistical Support XX Region but will not exceed the MAX AMOUNT price for the10% SURGE INCREASE CLIN.

13CO/COHow does the Government want Contractor Owned/Contractor Operated facility costs associated with ECS 171 input on the attached pricing schedule?New CLIN added.
14Pg 109-11, Sub-factor 1€, Attachment 12The solicitation says “Provide a detailed explanation of how the proposed number of employees per Job Classification at each Work Site will accomplish the work identified in the PWS based upon the estimated support needed specified in Attachment 12. If the proposed number of employees for a specific Job Classification at a Work Site is less than the estimated number of support hours required based on a 2080 hour work year, the offeror must identify how the remaining number of hours will be performed”. Attachment 12, however, uses an annual hours base of 1920. Are the correct annual hours for this solicitation 1920 or 2080? Our question is, does the Government plan to use 2080 hour work year for evaluation of this RFP, or will an adjustment be made considering that hour work year may / will vary for Exempt, SCA, and CBA employees?1920 will be the number of hours used for evaluation. Solictation will be revised to reflect 1920 throughout.
15GeneralHow many contracted workers are required to work at the CO/CO facility?Please see Attachment 12. 80%-90% of the contract workforce shown on attachment 12 for ECS-171 will be working at the CO/CO.
161.8.4.3The PWS states that Arms Rooms Operations are properly carried out at each ECS, but only ECS 170 and AMSA 85 have a Gunsmith II assigned. What is the role of the Gunsmith II at AMSA 85, and is it an error that ECS 171 does not have a Gunsmith II assigned?1.8.4.3 was changed to reflect Gunsmith qualifications rather than Arms Room Operations and is now 1.8.1.1. Attachment 12 was updated to reflect duties of Gunsmith.
17SupplementalThe solicitation states that contractor services may be required for up to 24 hours per day, 7 days per week (including holidays) during operational tempo. Can the Government provide historical data that includes overtime hours on Attachment 12 Density and Workload in order for Offerors to estimate their firm fixed price bids?This requirement was removed from the PWS and the supplemental information.
18SupplementalThe solicitation states that if the Contractor for his convenience desires to perform work during other than normal working hours, or if the Contractor is required to perform work at such times, they shall reimburse the Government for any additional expense occasioned by the Government. Will the Government modify this language to remove "or if the Contractor is required to perform work at such times" as Contractors should not be held liable for expenses incurred by the Government when the Government requires the Contractor to perform outside normal duty hours.Revised to remove "or if the contractor is required to perform work at such times."
19PWS 1.1The Description of Services/Introduction identifies services to be performed at locations identified in Attachment 10. Attachment 10 is the listing of Equipment. Can the Government clarify that this reference should be Attachment 9?PWS revised to read Attachment 9.
201.6.2The solicitation contains subparagraph 1.6.2.1 but there is no language in 1.6.2. Please clarify and advise if there is language missing from the solicitation.Paragraph 1.6.2 is titled Quality Assurance.
211.6.4.2The soliciation states that if there is a significant increase in workload, an option CLIN may be exercised by the Government. What does the Government consider a signficant increase and what measure will the Government utilize to make this determination?Future mission requirements could cause the government to exercise the 10% Surge CLINS.
221.6.4.3The solicitation states that due to OPTEMPO the Contractor shall be required to support extended hours and days of operation. The Contractor can expect an increase in workload throughout the option year periods. Where in the solicitation or attachments are these workload increases projected?The OPTEMPO increases are unknown. Any workload increases in the option years will be completed on the 10% Surge CLINS, as stated in PWS 1.6.4.2.
231.8.5.1
L-4.2The soliciation states that the Contractor shall designate one individual for each location, hereafter referred to as the PM, to serve as the central Contractor point of contact with the Government. Is it the intent of the Government that there be a Project Manager (PM) assigned at each location or can one PM be assigned responsibility over all locations? Subfactor 1(d) Key Personnel states Project Managers are required at each site for this requirement. Is the requirement to have a Project Manager at each site a valid requirement?One Project Manager Required. PWS 1.8.5.1 has been updated.
241.8.7.1The solicitation states the Contractor shall develop, implement, and maintain a site specific annual training plan. Will the Government accept a single annual training plan that addresses all sites applicable to the California Region?No, each facility should have a site specific training plan.
251.8.7.5The solicitation states that during the life of the contract, the Government may identify on-site or off-site training courses, such as New Equipment Training (NET) and the Contractor shall be responsible for any travel costs incurred by its employees to attend the course. Is the associated travel, in accorance with the JTR, a reimbursable expense under the Travel CLIN? If not, can the Government provide historical information on the required travel in order for Contractors to propose their firm fixed price bid?When the Government is requiring a training class and there's travel included, it should be invoiced in accordance to the Joint Travel Regulations to the travel CLIN. PWS 1.8.7.5 has been updated.
261.10.4The soliciation requires the Contractor to obtain any required permits to include CO/CO facilities. Can the Government provide details related to specific permits required at the CO/CO facility?No. Government does not have that data
274.5The soliciation states that the Contractor is responsible for all expendable and non-expendable items at CO/CO facility. Can the Government provide details related to specific items required at CO/CO facility?The CO/CO must be able to meet the PWS requirements of performing field level maintenance.
285.5.1The solicitation states that some maintenance at ECS 171 shall be performed at the Contractor Owned/Contractor Operated (CO/CO) facilities. Can the Government provide an estimate of the percentage of the work performed at the CO/CO facility?80%-90% of the contract workforce shown on attachment 12 for ECS-171 will be working at the CO/CO.
29L-4.2Subfactor 1(e) Management Plan reads "If the proposed number of employees for a specific Job Classification at a Work Site is less than the estimated number of support hours required based on a 2080 hour work year, the offeror must identify how the remaining number of hours will be performed. Can the Government confirm that this should read 1920 hours to agree with the basis of productive hours used in the Workload Density?1920 was used in the workload Density and L-4.2 has been updated to reflect 1920 hours.
30L4.4The solicitation states that offerors shall not go back any farther than 3 years for past performance. Would the government consider extending the recency from 3 years to 5 years in order to increase competition in the restricted SDVOSB pool?No, the past performance dates will remain.
31Attachment 9 & Attachment 12 Workload DensityAttachment 9 lists ten shops and locations. Attachment 12 only lists nine shops and locations. Attachment 12 does not have BMA 1 as per Attachment 9. The Workload Density does not include any data for AMSA85-BMA 1. Can the Government please provide the workload data for this location?BMA 1 is AMSA 85 BMA 1, all BMA workload is included in parent shop
32L-3.2.3The government indicates that "All text shall be single spaced and printed black on white paper." Subsequently, the government also indicates " Printing shall be easily readable". For ease of evaluation and readability, most contractors differentiate sections using non-black colored text for section/subsection headers. Please confirm that this is acceptable as long as body text is printed in black ink. Similarly, please confirm that graphics and tables can use color, as this often supports improved readability.Yes, this is acceptable.
33CLIN Structure Price ScheduleThe CLIN Structure in Attachment 2 contains 3 separate CLINS that contain different support locations. How should Contractors portray the cost for PMO proposed in support of this effort (i.e., split the effort proportionately between the CLINs or include them in the CLIN where the PMO employees are located)?CLIN added for Project Mananger
34Attachment 6, para 2The PWS references do not align with the references for associated services within the solicitation; for example, PWS 5.15 is Contractor Management Reporting, not Heavy Equipment Mechanic Lead. Can the government please clarify that the services required are accurate and provide the appropriate PWS references?See revisions made to Attachment 6
35PWS Para 5.2.1, Phase-In Plan96The referenced paragraph states that "The contractor shall submit the Phase-In Plan, and identify associated costs, as part of their proposal." However, Section L states that no costs will be stated in the Technical Volume.Request the USG clarify its intent with respect to Phase-In costs within the Phase-In Plan?The phase-in costs shall be identified on the Attachment 2 price schedule, not within the phase-in submission.
36PWS Para 1.10.4 & 4.7, CO/CO Facility and RFP Section M2.2, Phase-In89 & 95The PWS does not indicate a timeline for the CO/CO facility to achieve full operational capability, that is, the COCO being fully equipped with the proper vehicle lifts, compressors, tools, safety equipment and being certified by OSHA and State of California environmental and safety laws. Request the USG confirm that the CO/CO supporting ECS 171 shall be fully operational, with all appropriate local, state and Federal regulating agency required permits in hand, not later than the conclusion of the Phase-In period.The CO/CO will be operational at conclusion of Phase-in Period, IAW PWS 4.7. Government does not verify permits, that is up to Contractor.
37PWS Para 1.10.4 & 4.7, CO/CO Facility and RFP Section M2.2, Phase-In89 & 95None of the current evaluation factors, to include Phase-In and Management Approach evaluations, address if or how the offerror is complaint with the CO/CO facility requirements. Request the USG include its evaluation factor(s) and methodology for determining the technical acceptability for a fully opertational CO/CO facility.The requirement is to be at full performance at the conclusion of phase-in.
3852.212-5 CONTRACT TERMS AND CONDITIONS REQUIRED TO IMPLEMENT STATUTES OR EXECUTIVE ORDERS--COMMERCIAL ITEMS (JAN 2015)149Since this is a Small Business Contract, and in order to reduce the impact of the cash flow requirements of this contract, will 2 week invoicing be authorized under FAR 52.216-7?No, FAR 52.216-7 is for other than commercial items. This requirement has been determined to be a commercial service.
39RFP, PWS, 1.8.2 & 1.8.3, Equipment Operation Qualifications page 8383The costs associated with all Drivers of heavy equipment in California obtaining and retaining the required State of California and DOT physical needs to be priced in the FFP CLINs. Request the USG provide a listing of the costs incurred by the incumbent contractor in a typical year or allow these costs to be billed under a cost reimburseable CLIN.No. Government does not have that data.
40RFP, PWS, 1.8.2 & 1.8.3, Equipment Operation Qualifications83The costs associated with all Drivers in California obtaining and retaining a CDL needs to be priced in the FFP CLINs.. Request the USG provide a listing of the costs incurred by the incumbent contractor in a typical year or allow these costs to be billed under a cost reimburseable CLIN.No. Government does not have that data.
41PWS 5.16, Travel100Due to Department of Labor and California State laws, the contractor may be required to compensate TDY employees' base hourly rate at the WD rate for the TDY location. Will USG allow for equitable adjustments to compensate contractor for different rates arising from different WD Schedules at TDY locations?If the Government directs TDY as stated in the question an Request for an Equitable Adjustment may be considered.
42Attachment 2, Pricing ScheduleN/AWe understand that the California sites experiences higher than normal turn-over of personnel. Request the USG provide the average employee attrition rates over the last 3 years so that all offerrors are bidding to the same requirement.No. The government does not have this information.
43Attachment 2, Pricing ScheduleN/ACalifornia is a FUTA Credit Reduction state that has experienced significant increases over the normal FUTA payment and has projected more increases for 2017 and possibly further in the future. Request the USG provide its methodology for recouping the successful contractor these yet to be determined increases that are driven by statutory requirements..This may be reviewed as an equitable adjustment
44SF 1449, block 81The USG responses to offeror questions will significantly impact offerors' ability to clearly define the pricing requirements on this FFP effort. Request USG to delay submission of proposals by 15 working days from the time they respond to all questions to allow for answers to questions to be assessed, coordinated with teamates and costed?The response date can be found on FBO.gov and the Soliciation document SF 1449.
45PWS 1.6.6, Type of Contract78The referenced section of the PWS indicates that this is an "...Indefinite Quantity Indefinite Delivery (IDIQ) ". Request the USG clarify how this IDIQ will be administered.This IDIQ would be adminstered using task orders issued for services as needed.
46PWS 1.6.6, Attachment 2, Price Schedule; and RFP Section BMultipleThe PWS defines this contract type as FFP, Section B indicates all CLINs are FFP while Attachment 2 contains Cost Reimbursable CLINs. Request the USG please clarify this apparent inconsistency.CLINs for travel and materials are a fixed, not to exceed number. REIMBURSABLE-CLINs ARE FIRM FIXED PRICE AT THE PLUG NUMBER STATED IN THE CLIN. THE TOTAL COST FOR REIMBURSABLE-CLINs MAY NOT EXCEED FIRM FIXED PRICE MAXIMUM VALUE OF THE CLIN. ONLY COSTS AUTHORIZED BY THE GOVERNMENT MAY BE INVOICED AGAINST THE CLINS. THE GOVERNMENT WILL NOT PAY FOR ITMES THAT HAVE NOT BEEN USED.
47PWS Para 1.8.4 & 1.8.5 and Sections L & M85 & 86Request the USG change its PWS requirement so that only the single contract-level PM be subject to the Key Personnel requirements of the referenced section and not the designated lead positions at each location.One Project Manager Required. PWS 1.8.5.1 has been updated.
48PWS 1.9.7 PPE & CBAs - FHL/Barstow88The referenced section of the PWS and the CBAs require contractor to provide PPE at no cost to the USG. As PPE is a requirement of the PWS, request the USG consider changing this requirement to allow contractors to bill PPE as a cost reimbursable ODC.Cost of PPE should be considered part of OH and will not be cost reimbursable. PWS was revised and the line was removed that states provide PPE "at no cost to the government".
49PWS 1.12 Post Award Conference/Periodic Progress Meetings90The referenced section of the PWS requires contractor to meet this requirement at no additional cost to the USG. As these meetings are a requirement of the PWS, request the USG consider changing this requirement to allow contractors to bill these expenses as a cost reimbursable ODC.No.
50PWS 5.2.1 Phase-In Plan96The referenced section of the PWS states that "... the contractor shall prepare to assume full responsibility for all areas outlined in the PWS two (2) days after award." while the Phase-In period is 30 days in duration. Request the USG please clarify the difference between these two milestones.The contractor shall be ready to start phase-in within 2 days of award. PWS 5.2.1 was updated.
51RFP Section B and Attachment 2, Price ScheduleCLINs X013 and X014 are listed as FFP in the RFP and Cost Reimbursable in the Attachment. Request the USG please clarify this apparent inconsistency.These CLINs have fixed, not to exceed amounts and all expenses submitted against these CLINs have to be approved by the COR prior to the purchase. REIMBURSABLE-CLINs ARE FIRM FIXED PRICE AT THE PLUG NUMBER STATED IN THE CLIN. THE TOTAL COST FOR REIMBURSABLE-CLINs MAY NOT EXCEED FIRM FIXED PRICE MAXIMUM VALUE OF THE CLIN. ONLY COSTS AUTHORIZED BY THE GOVERNMENT MAY BE INVOICED AGAINST THE CLINS. THE GOVERNMENT WILL NOT PAY FOR ITEMS THAT HAVE NOT BEEN USED.
52Attachment 2, Price ScheduleThe FICA threshold for 2017 is higher than that mandated by the formula in Column Q. The actual FICA limit is $127,200 per FTE. The current formula prevents offerors from consolidating FTE requirements by Labor Category. Request the USG please provide an updated Price Schedule inclusive of this change.You may change the Price Schedule as you need; however, any changes need to have a separate explanation for the change.
53Attachment 2, Price ScheduleThe formula in Column Q (FICA) does not accurately represent the FICA buildup when multiple FTEs in the same Job Classification are entered in a row resulting in a cummulative amount for all FTEs in that row that exceeds the FICA threshold. Recommend the USG consider the following change to the formula in Column Q of referenced file.

From: ROUND(IF(P15<118500,P15*0.062,118500*0.062),2)+(ROUND((P15*0.0145),2))

To: ROUND(IF((P15/N15)<127200,P15*0.062,127200*0.062),2)+(ROUND((P15*0.0145),2))

Request the USG please provide an updated Price Schedule inclusive of this change.You may change the Price Schedule as you need; however, any changes need to have a separate explanation for the change.
54Attachment 2, Price ScheduleUnder this FFP, the USG has mandated that offerors use a specific FICA threshold for the entire term of the contract. FICA thresholds have been steadily increasing over the last several years. Request the USG address how it will monitor and make adjustments for changes to this statutory requirement that may impact offerors pricing in the out-years.You may change the Price Schedule as you need; however, any changes need to have a separate explanation for the change.
55Attachment 2, Price ScheduleState Unemployment Insurance varies by State. The current structure and formulas do not account for this type of calculation. Request the USG allow offerors to modify the costs elements and formulas to conform to their respective accounting practices.You may change the Price Schedule as you need; however, any changes need to have a separate explanation for the change.
56Attachment 2, Price ScheduleWorker's Compensation Rates vary by job classification and location. The current structure and formulas do not account for this type of calculation. Request the USG allow offerors to modify the costs elements and formulas to conform to their respective accounting practices.You may change the Price Schedule as you need; however, any changes need to have a separate explanation for the change.
57Attachment 2, Price ScheduleIt is not apparent how Offerors will integrate subcontractor pricing without making changes to the formulas in the Price Schedule. Request the USG provide instructions to all Offerors on how to incorporate sub-contractor pricing into ATT 2. Recommend adding a column to track Subcontractor name and then only require # FTEs, salary, hours, Fully Burdened rate and Fully Burdened Costs for subcontractors.Subcontractor pricing should not be priced out separately.
58Attachment 2, Price ScheduleDoes the USG anticipate having sub-contractors submit sealed bids and if so, will the USG provide separate instructions for sub-contractor sealed bids submissions?No, subcontractors are not to submit their own pricing. That is to be accounted for by the Prime in their price schedule.
59Attachment 2, Price ScheduleAs our indirect rate buildup does not align with the USG's cost elements and formulas, trying to map/align our actual cost elements into the current Attachment 2 structure will misrepresent our costs. Request the USG allow offerors to modify the costs elements and formulas to conform to their respective accounting practices.You may change the Price Schedule as you need; however, any changes need to have a separate explanation for the change.
60Attachment 2, Price ScheduleDue to the fact there are multiple CBAs in effect under this contract, with varying Fringe and H&W requirements, the single column provided in ATT 2 for H&W (Column W) does not allow offerors to map/align/include all of their cost elements. Request the USG allow offerors to modify the costs elements and formulas to conform to their respective accounting practices.You may change the Price Schedule as you need; however, any changes need to have a separate explanation for the change.
61Attachment 2, Price ScheduleRequest clarification on the following conflicting instructions contained in cell A8 of referenced document:
-- "DO NOT change any of the formulas embedded within these spreadsheets. If formulas must be changed please provide a detailed explanation as to why the formula was changed." Will an offeror's proposal be compliant if the formulas are changed and an explanation is provided?You may change the Price Schedule as you need; however, any changes need to have a separate explanation for the change.
62Attachment 2, Price ScheduleFor the purposes of pricing this proposal, please provide the anticipated Notice to Proceed (NTP) date.PWS 5.2.1 states Contractor shall be ready to start phase in within 2 days of award.
63Attachment 2, Price Schedule and CBAsThe latest change to wages and fringe benefits in the referenced CBA is Oct 2017. Please confirm that all offerors are required to propose at or above these wage and fringe benefit levels for the entire period of performance.Newest CBA is posted with this amendment. Use current CBAs. Should they update during the contract an equitable adjustment can be requested.
64RFP, Wage Determinations & Attachment 7As this RFP is for the California Region and RFP W911SA-17-R-3001 is for the Texas Region, it is unclear why AMSA 14 (Fresno, CA), AMSA 19 (Riverside, CA), ECS 16 (Los Alamitos, CA) and the PBT Support (Mountain View, CA) are not included in this RFP. Request the USG please clarify this apparent inconsistency.Attachment 7 is correct. Some California locations fall under W911SA-17-R-3001 based on the 63rd DOL's orgainizational structure and mission.
65Attachment 11Please confirm that the time standard units of measure in Att_11 are minutes.Attachment 11 measurements are in hours.
66RFP Section B3 thru 68CLINS #0001 through 4016 do not have their applicable Periods of Performance referenced in their description. Recommend the Government include each CLIN's Period of Performance to enable Offerors to enter their costs correctly.The Period of Performance for each CLIN is listed in a section called Delivery Information, beginning on Page121.
67RFP Section L & M110 & 116Section L Subfactor 1e (last bullet) talks about the contractor requirement to provide a detailed explanation of how employees will accomplish their work "...based upon the the estimated support needed specified in Attachment 12." Section M Subfactor 1e (last bullet) talks about the contractor requirement to provide a detailed explanation of how employees will accomplish their work "...based upon the the estimated support needed specified in Attachment 5." The section M reference to Attachment 5 appears to be a typo. Request the Government ensure the Section L and M requirements are the same.Updated to Attachment 12 in both sections.
68PWS Para 4.195This PWS paragraph states that "The contractor shall provide all maintenance personnel individual took kits”. Does the contractor provided tools have to be General Mechanic Tool Kits for all mechanic positions?The contractor will provide a tool box equivalent to the government issued Mechanics Master Mechanic box for all Inspectors, work leaders, and mechanics. PWS updated.
69PWS 4.1PWS Part 4.1 states that the contractor shall provide all maintenance personnel individual tool kits. However, Attachment 10 - Equipment California Region shows maintenance tool kits at each site location.This is a list of all government owned equipment. The Contractor provides a tool box equivalent to the government issued Mechanics Master Mechanic box for all Inspectors, work leaders, and mechanics and any additional personnel performing maintenance. Special tools in tool room can be signed out and used for specific task.
70PWS Para 4.795This PWS paragraph states that "This PWS paragraph states that "The contractor shall provide Contractor Owned/Contractor Operated (CO/CO) facilities to support requirements at ECS 171.”. Does the contractor also have to provide General Mechanic Tool Kits for the mechanics at the COCO?Contractor provides all tools at CO/CO to include a tool box equivalent to the government issued Mechanics Master Mechanic box for all Inspectors, work leaders, and mechanics.
71PWS Para 4.795This PWS paragraph states that "This PWS paragraph states that "The contractor shall provide Contractor Owned/Contractor Operated (CO/CO) facilities to support requirements at ECS 171.””.Does the contractor also have to provide all of the shop equipment such as lifts, compressors, air pressure driven tools, and wash stations?Yes.
72Attachment 14 and 15N/AThe two CBAs provided only go out to September 30, 2018. What does the Government want offerors to use for escalation of these CBAs beyond 2018?Attachment 15: CBA Fort Hunter Liggett has been updated. The CBA's in Attachments 14 and 15 are the most current available.
73Attachment 2, Price ScheduleN/AThe Government provided format in Attachment 2 does not have a CLIN associated with the overall contract Project Manager (PM). Request the Government provide a separate CLIN for Project Management Office costsCLIN added for Project Management
74Attachment 2, Price ScheduleN/AClarification of Available and Productive Hours for the Base Period..Request the Government confirm that for pricing purposes, the Phase-In Period is the first 30 days of the Base period and the remainder of the Base Period is 11 months in duration?The Phase-In period is 90 days, with the remainder of the Base Period being 9 Months. You may change the Price Schedule as you need; however, any changes need to have a separate explanation for the change.
75Attachment 2, Price Schedule and RFP M-1.3113The detailed price buildup of offerors burdens (i.e., Columns P thru AB of Attachment 2) is not required for the USG to conduct a price reasonableness evaluation of these FFP proposals. Request the USG eliminate the requirement for the detailed price buildup in columns P thru AB of Attachment 2 and allow offerors to replace these columns with one column that contains their Fully Burdened Labor Rate (FBLR) to the USG. That FBLR times the proposed hours will provide the proposed price for each line item.No columns will be removed
76Attachment_9_Worksite_Locations_CA_Region_Revised_201706231AMSA-13 is located in Vallejo, CA, yet the "Attachment 9 Worksite Locations CA Region Revised 20170623" document lists it as Port Hueneme, CA. Can the Government please reissue the Attachment_9_Worksite_Locations_CA_Region_Revised_20170623 document to reflect AMSA-13 being located in Vallejo, CA?Attachment 9 is correct.
77Attachment_7_Wage Determinations_Full_Length_2017091113 of 73AMSA-13 is located in Vallejo, CA, (Solano County), yet Attachment 7 lists WD 2015-5625; REV 4 dtd 8/3/2017 (Ventura County) as the Wage determination that applies. Request the Government revise Attachment 7 to reflect the correct Wage Determination schedule for AMSA-13 (located in the city of Vallejo, CA and the county of Solano, CA).Attachment 7 is correct.
78Attachment_4_Deliverables _CA_Region2The HOT Training mission is not part of the CA (3000) solicitation, yet the Attachment_4_Deliverables_CA_Region document references a HOT Status Report. Recommend the Government reissue the Attachment_4_Deliverables_CA_Region document without the HOT Status Report requirement.Attachment 4 Deliverables revised to remove the HOT mission.
79RFP L-4.2, and L-4.2 Subfactor 1(e) last bullet109This bullet comment states "Identification of proposed subcontractors and a discussion of the communications and internal control procedures that will be employed in order to ensure timeliness and quality of all subcontracted effort and how this work will be coordinated." In L-4.2, the RFP states that "The Technical Part shall not contain the name of the company, subcontractors/team members or individual/persons names (Except for in subfactor 1d) and shall identify their firm by DUNS number one time only on the cover page." Request the Government clarify their instructions in the last bullet on p 109 for Subfactor 1e as to how they want Subcontractors identified in the Technical Volume.Remove the requiment for " "Identification of proposed subcontractors " from L &M in Subfactor 1(e )
80Attachment 3, (#7 & #8) PRS DOL Maintenance and PWS Part 7PRS p3; PWS p 102The final two (2) Performance Requirements Summaries (PRS) listed in the referenced attachment cite Technical Exhibit Listings Processes in PWS Part 7. PWS Part 7 has no Technical Exhibit Listings Processes.Request the USG clarify this apparent inconsistency.PRS has been updated from "Technical Exhibit" to "Attachments."
81Attachment 12 and PWSN/AAttachment 12 references a Labor Category called "Maintenance Program Coordinator" for all sites listed. The PWS has no references to this position. Request the Govt provide a job description and any required qualifications for the Maintenance Program Coordinator.The term is used on Attachment 12 as that's what the incumbent has. Each vendor may determine the best way to perform the work in PWS 5.13.2
82Attachment 14 and 15N/AThe two CBAs provided only go out to September 30, 2018. . Are there any other CBAs currently in place or scheduled to be in place at any of the locations covered under this solicitation during the period of this contract?Attachment 15: CBA Fort Hunter Liggett has been updated. The CBA's in Attachments 14 and 15 are the most current available.
83Attachment 14 and Attachment 12The Density and Workload attachment shows an Electronics Maintenance Tech for the Barstow location. However, the Barstow CBA attachment does not list the position with a labor rate. Are we to use the WD for the Barstow location to price the Electroinics Maintenance Tech position? Or will the Government provide a labor rate for the Electronics Maintenance Tech on the CBA?
Use SCA
84PWS 5.5.2 Phase In FacilitiesThe contractor will be provided a maximum of two administrative office spaces during the phase-in period of the contract co-located with one of the Primary COR. Willl the Government provide the location of the Phase-In office space? Is this space only available during phase-in? What location will the Project Manager work from after completion of Phase-In?
PWS 5.2.2 has been revised.
85Attachment 2, Price SchedulePlease clarify if the Attachment 2 Price Schedule can be adapted to consider a bidder’s approved accounting practices. For instance, there does not appear to be a column to accommodate Holiday/Sick Vacation leave costs on the spreadsheet. Can a bidder add these columns to represent how costs are actually accumulated? If not, where should those costs be captured?You may change the Price Schedule as you need; however, any changes need to have a separate explanation for the change.
86Attachment 2, Price ScheduleWhat cost estimating assumptions should be made for CBAs that are planned to expire during the period of performance of the new contract? For instance, should all offeror’s propose the balance of the contract periods at the current CBA rates?Attachment 15: CBA Fort Hunter Liggett has been updated. The CBA's in Attachments 14 and 15 are the most current available.
87Attachment 2, Price ScheduleShould overtime be considered in development of the offeor's prcing? If so, at what percentage?No, overtime should not be factored into the price schedule. It is the contractor's responsibility to schedule work, based on workload in Attachment 12, to be completed using regular hours.
88Attachment 2, Price Schedule cell H14Would the Government define what Workload Indicator refers to?Refer to the Price Schedule. See the tab titled "New Directions" for an example.
89Attachment 2, Price Schedule, CBAsShould shift work be considered at ECS 170 and 171 in the development of the offer's pricing?That is at the vendors discretion.
90Attachment 2, Price ScheduleWhere would the offeror list costs for California GRT and other mandated taxes required specific to this effort?You may change the Price Schedule as you need; however, any changes need to have a separate explanation for the change.
91Attachment 2, Price ScheduleWould the Government consider removing Phase-In as part of the cost evaluation?No.
92Attachment 2, Price ScheduleWhere does the Government require us to price the ODC and PPE requirement?It should be included wherever it is appropriate based on accounting standards.
93COCO Maintenance FacilityThe RFP does not describe the size of the CO/CO maintenance facility required. How many maintenance bay doors does the Government require?The CO/CO needs to be able to accommodate the type of work required in the PWS and Attachment 11 and 12.
94COCO Maintenance FacilityIs the Government LIS system being used in the COCO Maintenance Facility? Or is the contractor being required to provide a COTS solution?GCSS Army will be used
95Attachment 12Workload data provided is for 2015-2016. Would the Government provide more current workload data, i.e., 2016-2017 to base our calculations on?Contractor will propose based upon the data provided. Any differences between current workload and the data provided should not be factored into proposals. Any increases in workload not reflected in Attachment 12 will be acquired using the 10% surge CLINs.
96Key Personnel RequirementHow many resumes are required to be submitted? Are resumes only required for Key Personnel?See the requirements in Addendums to 52.212-1 and 52.212-2.
97Attachment 11 - DOL Equipment Time StandardsWhat is the intent and purpose of Attachment 11 63RD RSC EQUIPMENT TIME STANDARDS?These are time standards our facilities use by equipment type by task
98Part 6.0 Applicable PublicationsPlease make available the referenced publications to preclude any unfair advantage to the incumbent who has ready excess to these publications.No, Local SOPs are working documents that changes daily, these documents will not be furnished but will not deviate from relevant regulations.
99Attachment 14 and Attachment 15The labor title Maintenance Program Coordinator and Electronics Maintenance Technician do not appear in either CBA. Are the two positions intentially omitted form the CBAs? Are the two positions subject to the DOL SCA? If so, do you intend to incorporate the applicable WD? If not, are the positions currently classified as Exempt?The Maintenance Program Coordinators and electronic maintenance technicians are not covered in the Collective Bargaining Agreement is covered by SCA.
100INSTRUCTIONS TO OFFERORS (L-3)Part I and Part III list the SF1449. Do offerers have to included the entire completed and signed Sf 1449 in both sections?See the requirements in Addendums to 52.212-1 and 52.212-2.
101Attachment 13The Attachment was not posted on FBO or incldued with the other attachments but is listed in Part 7 Attachment Listing.The Attachment is listed as Blank at time of initial posting. It is listed as a placeholder for the the Government Responses to Submitted Vendor Questions which is posted through Amendments.
102INSTRUCTIONS TO OFFERORS (L-1)Are subcontractors required to submit a Part III Factor 2: Price Attachment 12?Subcontractors are not required to submit anything directly to the government.
103INSTRUCTIONS TO OFFERORS (L.1.3)Please provide the sign in sheet and any presentations and information communicated during the site visits.There were no presentations given at the site visits. All questions from the site visits were to be submitted by email to the MICC Fort Mcoy Contracting Office to be answered in Attachemtn 13. The sign in sheets will not be released by the Government.
104Position Specific Qualifications (1.8.4)The section provides for qualifications for the Project Manager and Supervisors. Are these the designated key positions? If so, why are three (3) positions identifed in Subfactor 1(d): Key Personnel. Please clarify/correct.Project Manager and Supervisors are designated key positions.
105Attachment 2, Price ScheduleThe Price Schedule does not account for the inclusion of retirement costs required by the CBAs. Will the Government allow for the contractors to revise the model to include this cost or will the Government provide a revised model?You may change the Price Schedule as you need; however, any changes need to have a separate explanation for the change.
106Attachment 2, Price ScheduleThe Price Schedule does not account for the inclusion of vacation, holiday, or sick leave costs required by the WDs and CBAs. Will the Government allow for the contractors to revise the model to include this cost or will the Government provide a revised model?You may change the Price Schedule as you need; however, any changes need to have a separate explanation for the change.
107Attachment 2, Price ScheduleThe Price Schedule does provide for the inclusion of subcontractor(S) costs. Will the Government allow for the contractors to revise the model to include this cost or will the Government provide a revised model?Subcontractor cost shall not be broken out separately on the price schedule.
108Attachment 2, Price ScheduleThe Price Schedule assumes 1920 productive hours/FTE which does not account for Sick Leave required by all WDs and CBAs or alternate vacation/PTO. Will the Government allow for the contractors to revise the model to include this cost or will the Government provide a revised model?The Price Schedule reflects 2,080 hours in column "O" and does account for Sick Leave required by all WDs and CBAs or alternate vacation/PTO.
109Attachment 2, Price ScheduleWill the Government provide more detail on what PRS# refers to?PRS # refers to the number on Attachment 3 PRS.
110Attachment 2, Price ScheduleThe Price Schedule does not allow for pricing Gross Receipt Tax required by some state. Will the Government allow for the contractors to revise the model to include this cost or will the Government provide a revised model?You may change the Price Schedule as you need; however, any changes need to have a separate explanation for the change.
111Attachment 2, Price ScheduleWill the Government provide a CLIN for pricing ODCs or a Cost Reimbursable plug number?No.
112RFP, Factor 2: Price, Paragraph 3117The offeror's total price for the purpose of evaluation will include the phase-in, base period, 1st Option, 2nd Option, 3rd Option, 4th Option, Phase-out, six month extension, and CMRA. Will the Government consider removing Phase-in for the evaluation criteria to remove any incumbent advantage?No
113PWS 4.7
CO/CO FacilityStates that the contractor shall provide Contractor Owned/Contractor Operated facilities to support maintenance requirements at ECS 171. There does not appear to be a way to provide pricing for this facility in Attachment 0002. Will the Government clarify how offeror's are to provide pricing information for this facility in Attachment 0002?CLIN x017 has been added to Attachment 2.
114PWS 4.7
CO/CO FacilityWhere is the CO/CO located?Within 20 miles of ECS 171 as stated in PWS 4.7.
115PWS 4.7
CO/CO FacilityWhat is the number of bays in the current CO/CO and what is the building size?The government does not have this data
116PWS 4.7
CO/CO FacilityDoes the CO/CO building require lift capability?PWS 4.7 was updated to reflect the CO/CO must be able to meet the PWS requirements of performing field level maintenance.
117PWS 4.7
CO/CO FacilityIs the CO/CO facility using FLMS GCSS, or other STAMIS system, or is the contractor providing a COTS solution?GCSS will be used, maintenance request will be loaded from supported shop
118PWS 4.7
CO/CO FacilityWhat is the purpose of the CO/CO, i.e. overflow, used daily, full workload, or only as needed?Full workload
119PWS 4.7
CO/CO FacilityIs there workload density available for the CO/CO?Identified in the ECS-171 workload attachment 12.
120PWS 4.7
CO/CO FacilityHow many work orders do they process annually at the CO/CO?Identified in the ECS-171 workload attachment 12.
121PWS 4.7
CO/CO FacilityHow many FTE are required to support the work done at the CO/CO?Identified in the ECS-171 workload attachment 12.
122PWS 4.7
CO/CO FacilityAre vehicles transported between the COCO facility and the Government maintenance facilities?Yes
123PWS 4.7
CO/CO FacilityWho transports/drives the vehicles to and from the CO/CO?The Contractor.
124PWS 4.7
CO/CO FacilityWhat security do we need for the COCO facility - fence, gate, locks, guards, lighting?Addresssed in PWS 1.6.8.2
125PWS 4.7
CO/CO FacilityIs there a size requirement for the parking space adjacent with the CO/CO facility?Determined by contractor and how often equipment is moved from supported shop.
126PWS 4.7
CO/CO FacilityWill the Government provide the address of the incumbent CO/CO building?No
127PWS 4.7
CO/CO FacilityWill the government identify the positions and number of positions that are subject to 2nd shift premiums?This is determined by Contractor and workload of both first and second shifts.
128PWS 4.7
CO/CO FacilityCan an assessment of historical overtime hours be provided? In lieu of this information will overtime be considered within the surge CLINs?Any government required OT would be covered by an equitable adjustment.
129PWS section L-3.2.3 statesThis section states: “Printing shall be easily readable (12-pitch type or 10 point proportional spacing.)” As Microsoft Word does not contain a selectable setting for font ‘pitch’, should the instruction read “12-point font”? Are proportional spacing fonts considered by the Government to be monospaced fonts, such as Arial and Courier? Or, will the Government accept proposals that utilize 10-point “Justified” font spacing?
Vendor must submit using the requirements listed in the Addendum to 52.212-1 and 52.212-2
130L Section, Subfactor 1(d),108This requires a project Manager at each site. Does this mean that a project manager is required at the two ECS' and the 7 AMSAs?One Project Manager Required, see PWS 1.8.5.1.
131Attachment 12The two ECS' indicate a requirement for a site manager. Is this the same as the project manager specified in the RFP, L-Section, Subfactor 1(d), Page 108?One Project Manager Required, see PWS 1.8.5.1.
132RFP, Pages 4, 5 & 6Items 0002, 0003 & 0004 all appear to be the same and there recurrening instances of this in the remaining items. Can the Government please explain this requirement?Each are option CLINs that may be exercised if surge workload comes in.
133L-Section L-4106Can the Government verify this requirement as normally Teaming Agreements are propriatary information between the prime and subcontractor?Yes, this is a requirement.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .