THIS DOCUMENT IS APPROVED FOR PUBLIC RELEASE; DISTRIBUTION IS UNLIMITED.
DISTRIBUTION STATEMENT A
DIRECTED BY THE DESIGN ACTIVITY.
THIS DRAWING HAS BEEN GENERATED AND
IS MAINTAINED BY A CAD SYSTEM.CHANGES
SHALL ONLY BE INCORPORATED AS
30°
5 3
2.
48.00
84.00
2.50±.25
A
B
OVERLAP
2.
DETAIL A
DETAIL B
SCALE: 1/4
3.
TYPICAL WALL CONSTRUCTION
REVISIONS
ZONE LTR DESCRIPTION PROJ OFCR APVD DATE
- INITIAL RELEASE PER DR-S-017-11 K.H. E.A. 11-08-26
A REVISED PER DR-S-018-11 K.H. E.A. 11-09-01
B REVISED PER DR-S-019-11 K.H. E.A. 11-09-08
C 15-12-16
- 81337 NSN 8340-00-
985-7461 TENT PEG - 6
- 81337 5-10-2022-9 WING NUT - 5
- 81337 5-10-0208-1 GROUND ANCHOR BRACKET - 4
- 81337 5-10-2022-1 TOGGLE HANDLE, ASSEMBLY - 3
- 81337 5-10-2021-1 SUPPORT STRUT, WELDED ASSEMBLY,
MBPS - 2
- 81337 5-10-2023-1 BLAST PANEL - 1
QTY
REQD CAGE CODE
PART OR
IDENTIFICATION
NO.
NOMENCLATURE OR DESCRIPTION COMMENTS
SPECIFICATION
FIND
NO.
PARTS LIST
B
A
C
D
7 6 5
E
F
G
H
8 7 6 5
4 3 2 1
A
SH
T
D W
G N
O
C
D
4 3 2
E
F
G
H
APPROVAL DESIGN ACTIVITY
INTERPRET THIS DRAWING IN
ACCORDANCE WITH ASME Y14.100 APPLICATION
USED ON
UNLESS OTHERWISE SPECIFIED:
NEXT ASSY
DIMENSIONS ARE IN INCHES
TOLERANCES:
DRAWN BY
APPLICABLE SPEC
PROJ OFCR
APPROVED
CHECKED
DATE
SCALE: SHEET 1 OF 2UNIT WT.
KANSAS STREET, NATICK MA, 01760-5056
U.S. ARMY NATICK SOLDIER
RESEARCH, DEVELOPMENT & ENGINEERING CENTER
DRAWING NO.CAGE
81337
SIZE
E
NOTES:
-2 PLACE DIM
3 PLACE DIM
ANGLES 20.NOV.2015
5-10-2021
EXPEDITIONARY SHELTER
PROTECTION SYSTEM
(ESPS)
None
5-10-2020
10-
W. RICCI
DRAWING REPRESENTS A SINGLE MODULE.
PANEL UNITS SECURED TO GROUND WITH FN
6(TENT PEGS) THRU FN 4(GROUND ANCHOR
BRACKET) AND FN 2(SUPPORT STRUT).
PANEL UNITS ATTACHED TO EACH OTHER BY
PASSING COIL THREAD ROD THROUGH
CORRESPONDING HOLES AND TIGHTENING WING
NUT.
1.
2.
3.
THIS DOCUMENT IS APPROVED FOR PUBLIC RELEASE; DISTRIBUTION IS UNLIMITED.
DISTRIBUTION STATEMENT A
DIRECTED BY THE DESIGN ACTIVITY.
THIS DRAWING HAS BEEN GENERATED AND
IS MAINTAINED BY A CAD SYSTEM.CHANGES
SHALL ONLY BE INCORPORATED AS
A
B W
DETAIL A
SCALE: 1/1
OUTSIDE PANEL EDGE
SUPPORT STRUT
DETAIL B
SCALE: 1/2
C
SUPPORT STRUT W/TENT PEG ANCHOR BRACKET W/TENT PEG
LOWER CORNER SLOT UTILIZED FOR
ANCHOR BRACKET AND TENT PEG FOR
NORMAL SEQUENCE, ALL PANELS
LOWER RIGHT CORNER
SLOT NOT UTILIZED
FOR A NORMAL SEQUENCE
UNTIL END PANEL
C
C
DETAIL W
SCALE: 1/4
SECTION C-C
SCALE: 1/2
C
(OUTSIDE PANEL)
REVISIONS
ZONE LTR DESCRIPTION PROJ OFCR APVD DATE
- INITIAL RELEASE PER DR-S-017-11 K.H. E.A.
A REVISED FOR DR-S-019-11 K.H. E.A. 11-09-08
B 15-12-16
B
A
C
D
7 6 5
E
F
G
H
8 7 6 5
4 3 2 1
A
SH
T
D W
G N
O
C
D
4 3 2
E
F
G
H
SCALE: SHEET 2 OF 2UNIT WT.
DRAWING NO.CAGE
81337
SIZE
E
1/1
5-10-2020
5-10-2020
| 5-10-2020S1 |
| Drawing View1 |
| Drawing View2 |
| Detail View A (1 : 8) |
| Detail View B (1 : 4) |
| 5-10-2020S2 |
| Drawing View6 |
| Detail View A (1 : 1) |
| Detail View B (1 : 2) |
| Drawing View9 |
| Detail View W (1 : 4) |
| Section View C-C |