Attachment_0077_-_Example_Data_for_Battery_Modeling.pdf
PDF 480 KB Posted
- Attached to
- Common Robotic System (Individual) CRS(I)
- Solicitation number
- W56HZV-16-R-CRSI
About this file
Draft Attachment 0077
View the file
Other files
Show 40 more
Latest 50 of 58 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UNCLASSIFIED
Attachment 0077
Example Data for Battery Modeling
(This cover sheet is unclassified.
DISTRIBUTION STATEMENT A. Distribution authorized for Public Release
Technical Specifications Part No. UBBL10-01 NSN Equivalent to 6140-01-490-4316 Voltage Range 30V Mode: 20.0 to 33.6V
15V Mode: 10.0 to 16.8V Average Voltage 30V Mode: 29.6V
15V Mode: 14.8V Capacity 30V Mode: 7.8Ah @ 0.5A @ 23°C
15V Mode: 15.6Ah @ 1.0A @ 23°C Max. Discharge 30V Mode: 10.0A continuous
15V Mode: 20.0A continuous Max. Pulse Discharge 30V Mode: 18.0A for 5 seconds
15V Mode: 36.0A for 5 seconds Energy 230Wh Energy Density 171Wh/kg, 256Wh/l Weight 1340g Cycle Life > 300 cycles @ C/5 to 80% of initial capacity @ 100% depth of discharge Memory No Memory Effect Operating Temperature -32°C to 60°C Storage Temperature -32°C to 60°C Self-Discharge < 5% per month Exterior/Housing Hard plastic, desert tan (Noryl N190X-701) Terminals/Connector Connector SC-C-179495 Communications SMBus v1.1 communication protocol
SBD v1.0 data set support State of Charge Indicator 5-segment LCD display Safety Material Safety Datasheet - MSDS041
Refer also to Safety Guide UBI-5112 Qualification Designed to meet U.S. Army MIL-PRF-32383/3 Transportation Class 9 International and within U.S. unless shipped by motorcar or rail within U.S. (see note) Harmonized Tariff Schedule 8507.60.0020 Protection Over Voltage Limit: 4.30V (per cell)
Under Voltage Limit: 2.40V (per cell) Over Current Protection: 23.0A Re-settable Fuse: Activates @ 70°±5°C
Re-sets @ 50°±5°C One-Time Thermal Fuse: Activates @ 93°±5°C
Charging Recommended charge rate is 3.0A to max voltage of 16.8V in a temperature range of 0°C to 45°C. Hold at 16.8V until current declines to 300mA. Max charge rate is 4.8A.
Note A complete description of transportation regulations, lithium weights and transportation classifications is available on the Ultralife website.
Features
• Designed to meet U.S. Army MIL-
PRF-32383/3
• Rugged, military tough case construction
• SmartCircuit Technology® - Implements
SMBus v1.1 smart battery technology
• Flexible output voltage
• State-of-Charge display
• High energy density
Applications
• Rugged, portable electronics
• Robotics / AUVs / UUVs
• Military communication devices
• AN/PRC-117G, AN/PRC-117F, AN/PRC-
119, AN/PSC-5D
Optional Accessories
• UCH0056: Smart Desktop Charger
• CH0002: COTS Desktop Charger
• CH0003 or MRC-86: 6-bay Charger
• CH0004 or MRC-85: 2-bay Charger
• MRC-88: 5-bay Charger
• MRC135A: Single Unit Solar Charger
• MRC-143A: 3-Unit Solar Charger
• UKT0011: Portable Battery System
• CA0003: 4 Conductor Cable
• CA0003: Vehicle Adapter
• CA0006: 24V, 2 Conductor Cable
• CA0007: 12V, 2 Conductor Cable
• CA0008: 12/24V, 4 Conductor Cable
• UCA0039: Shielded Smart Cable
BB-2590/U SMBus Technical Datasheet
BB-2590 SMBus Newark, New York | 315-332-7100 | Fax: 315-331-7800
©2015 Ultralife Corporation • www.ultralifecorp.com • All information is subject to change without notice.
The information contained herein is for reference only and does not constitute a warranty of performance. • 25 AUG 15 UBM-0084 Rev: C
Dimensions
BB-2590 SMBus Newark, New York | 315-332-7100 | Fax: 315-331-7800
©2015 Ultralife Corporation • www.ultralifecorp.com • All information is subject to change without notice.
The information contained herein is for reference only and does not constitute a warranty of performance. • 25 AUG 15 UBM-0084 Rev: C
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5
Ca pa ci ty
(A h)
Vo lta ge (V
C ur re nt (A
Time (Hours)
Single Side Charge @ 23°C 16.5V Constant Voltage with 3A Current Limit
Voltage
Current
Capacity
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 8.0
Vo lta ge (V
Capacity (Ah)
10A Constant Current Discharge Test Series Mode (33.2V) @ 23°C
Thermal protection actuates before voltage cutoff.
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0
Cu rr en t (
A)
Vo lta ge (V
Capacity (Ah)
Motor Inrush Test Series Mode (33.2V) @ 23°C
Voltage
Current
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Cu rr en t (
A)
Vo lta ge (V
Capacity (Ah)
36A Pulse Discharge Test (5s / 25s) Parallel Mode (16.5V) @ 23°C
Voltage
Current
0 1 2 3 4 5 6 7 8 9 10
Vo lta ge (V
Capacity (Ah)
Constant Current Discharges @ 23°C Individual Sections (Charged to 16.5V)
500 mA
1A
2 A
3 A
4 A
5 A
6 A
8 A
2A (Charged to 16.8V)
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Vo lta ge (V
Time (Hours)
500mA 2A 4A 8A 500mA 2A 4A 8A 500mA 2A 4A 8A
-20° C
23° C
60° C
Thermal protection actuates before voltage cutoff during 8A discharge at 60° C
Constant Current Discharges - Various Rates & Temperatures Individual Sections (16.5V)
Performance Graphs
BB-2590 SMBus Newark, New York | 315-332-7100 | Fax: 315-331-7800
©2015 Ultralife Corporation • www.ultralifecorp.com • All information is subject to change without notice.
The information contained herein is for reference only and does not constitute a warranty of performance. • 25 AUG 15 UBM-0084 Rev: C