P-601_REVISED.pdf

PDF 210 KB Posted

Attached to
B113 Solicitation Federal contract opportunity
Solicitation number
W50S98
Issued by
Department of the Army Tennessee Army National Guard

About this file

This document contains plumbing schedules and details for Repair Building 113 at the Tennessee Army National Guard McGhee Tyson Air Base in Alcoa, Tennessee. It specifies plumbing fixtures such as an emergency shower/eyewash, electric water cooler, floor drain, undercounter lavatory, washing machine outlet box, and floor-mount water closet. It also includes schedules for electric water heaters located in various buildings and for a breathing air compressor system in Building 134. Product manufacturers and models are identified for most fixtures. Installation details are provided for items such as the emergency shower/eyewash, pipe penetrations, and electric water heaters. Notes cover requirements for exposed piping, P-traps and supplies, insulation, and vent and drainage sizes. The related federal contract opportunity is solicitation number W50S98 for Building 113 repairs with an option to demolish Buildings 110 and 111, issued by the Department of the Army Tennessee Army National Guard.

View the file

Other files for this federal contract opportunity

Other files attached to B113 Solicitation, newest first.
File Type Posted
OF 1419 Abstract.pdf PDF
OF 1419 Abstract.pdf PDF
Sign in Sheet - 23 Aug 2022 10am.pdf PDF
B 113 As Built Drawings.pdf PDF
W50S98-22-B-000100002.pdf PDF
Demo 110_110 Drawings GC002 003 004 005.pdf PDF
BLDG 111 Asbestos Info.pdf PDF
05 40 00 Cold-formed Metal Framing 20220805.pdf PDF
Demo Drawings CS503-506.pdf PDF
REGISTER-upate 07292022.pdf PDF
1190113_TNANG_B113_ELEC-ADDENDUM 1-072622.pdf PDF
W50S98-22-B-000100001.pdf PDF
1190113_TNANG_B113_FIRE-ADDENDUM 1-072622.pdf PDF
28 31 76 - updated.pdf PDF
Pre-Bid Slides B113.pdf PDF
Pre-Bid Sign in Sheet B113.pdf PDF
MTANG Demo 110 and 111 drawings.pdf PDF
W50S98-22-B-0001 21 July 2022.pdf PDF
Repair Building 113 Spec. Volume 1.pdf PDF
Repair Building 113 Drawings.pdf PDF
Repair Building 113 Spec. Volume 2.pdf PDF
Show all 21

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LAVATORY

WATER HEATER

MOUNTED ON

WALL

BELOW LAVATORY

CW SUPPLY VALVE

CW

HW

FAUCET

NOTE: COORDINATE WITH ELECTRICAL

ON POWER CONNECTION.

NOTE:

PIPE PENETRATIONS

AT

FIRE RATED WALLS

SHALL BE A UL LISTED

ASSEMBLY

FINISHED WALL

SEALANT-JOINT 1/4"

WIDE MIN. BY 3/8"

DEEP.

METAL JACKET

SLEEVE

INTERIOR SIDE

ESCUTCHEON

PIPE WITHOUT

INSULATION

PIPE WITH

INSULATION

INSULATION

BACKUP MATERIAL

PIPE

ANSI COMPLIANT

IDENTIFICATION

SIGN

TEMPERED

WATER SUPPLY

INLET, 70 DEG F

DELUGE TYPE

EMERGENCY

SHOWER

PULL HANDLE

FOR SHOWER

PUSH PLATE

FOR EYE

WASH

SUPPORT BASE,

SECURE TO FLOOR

PER MANUFACTURER'S

REQUIREMENTS

FINISHED FLOOR

DRAIN TO

FLOOR

EMERGENCY EYE WASH

ALARM HORN

FLOW SWITCH

FINISHED WALLSTAY-OPEN VALVE

STAY-OPEN VALVE

STROBE LIGHT

NOTE:

1. EMERGENCY EYEWASH/SHOWERS SHALL CONNECT TO THE FIRE ALARM SYSTEM.

2. PROVIDE MOVABLE CURTAIN FOR PRIVACY.

DRAIN VALVE (TYP)

BALL VALVE (TYP)

UNION (TYP)

CHECK VALVE (TYP)

EWH

T&P RELIEF

VALVE

1-1/4"CW SUPPLY

1-1/4" TEMPERED WATER

CONNECTION DIRECTLY

TO EMERGENCY EYEWASH

AND SHOWER

EWH IN NEMA 4 EXPLOSION

PROOF CABINET

1. MOUNTING HEIGHT 24" AFF.

NOTES:

1 2 3 4 5

A

B

C

D

SHEET ID

P a rk w a y L a n e

S u it e

P e a c h tr e e C o rn e rs

G

A

P h o n e

-7

F a x

(6

-7

S

IZ

E

A N

S I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

D A

T E

D E

S C

R

IP

T

IO

N M

A R

K

/1

/2

:3

:5

B

IM

/1

T N

A N

G R e p a ir

B ld g

F u e l C e ll/

T

N A

N G

B v

M P

F P

.r v t

P-601

100% REVISED

P L U

M B

IN

G

S C

H E

D U

L E

S A

N D

S C

H E

D U

L E

S

R E

P A

IR

B

U

IL

D

IN

G

T

H T

E N

N E

S S

E E

A

IR

N A

T

IO

N A

L G

U A

R D

M c G

H E

E T

Y S

O N

A N

G B

A S

E A

L C

O A

T

E N

N E

S S

E E

T E

N N

E S

S E

E

A

IR

N A

T

IO

N A

L G

U A

R D

A L C

O A

T

E N

N E

S S

E E

J O

B N

O

J N

A

IZ

E R

J F

L Y

N N

J L E

D Y

A R

D

M

A R

C H

S O

L -X

X -X

-X X

X X

W L -1

-D

-0

X X

-X -X

X X

X G

K

E R

R

PLUMBING FIXTURE SCHEDULE

TAG FIXTURE TYPE

CW PIPE

SIZE

HW PIPE

SIZE

WASTE

PIPE SIZE

VENT PIPE

SIZE

FLOW

RESTRICTION

BASIS OF DESIGN

MANUFACTURER MODEL DESCRIPTION

ESEW EMERGENCY

SHOWER/FACEWASH

1-1/4" 1-1/4" -- -- 20 GPM GUARDIAN G1696 FREE-STANDING, STAINLESS STEEL HEAD, #G3800LF THERMOSTATIC

MIXING VALVE TO DELIVER 70°F TEPID WATER. PROVIDE #AP275-200

ELECTRIC FLASHING LIGHT, FIRE ALARM, AND LOCAL ALARM HORN.

EWC-1 ELECTRIC WATER COOLER 1/2" -- 2" 1-1/2" -- MATCH

EXISTING

MATCH

EXISTING

ADA, STAINLESS STEEL, SINGLE WALL-MOUNT WATER COOLER WITH

ENHANCED EZH2O BOTTLE FILLING STATION, ZURN #Z1225 SUPPORT.

FD-1 FLOOR DRAIN -- -- 3" 2" -- ZURN Z1400 CAST IRON FLOOR DRAIN WITH 8" CAST IRON GRATE, CAST IRON

SEDIMENT BUCKET, MEMBRANE CLAMP, AND TRAP PRIMER CONNECTION.

LV-1 UNDER-COUNTER MOUNT

LAVATORY

1/2" 1/2" 2" 1-1/2" 0.5 GPM MATCH

EXISTING

MATCH

EXISTING

PROVIDE WITH P-TRAP (KOHLER K-8998) AND DRAIN COVER. MOUNT TO

COUNTER AS SHOWN PER ARCHITECTURAL DRAWINGS. PROVIDE

HARDWIRED SENSOR FAUCET AND THERMOSTATIC MIXING VALVE.

WB-1 WASHING MACHINE

OUTLET BOX

1/2" 1/2" 2" 2" -- SIOUX CHIEF 696-2313MF FULLY RECESSED WASHING MACHINE SUPPLY BOX WITH COVER.

PROVIDE 1/4 TURN BALL VALVES AND WATER HAMMER ARRESTORS IN

BOX. PROVIDE A 2” TRAPPED STANDPIPE IN CONCEALED WALL SPACE.

WC-1 FLOOR-MOUNT WATER

CLOSET

1" -- 4" 2" 1.28 GPF MATCH

EXISTING

MATCH

EXISTING

PROVIDE WITH ELONGATED OPEN END SEAT. PROVIDE WITH HARDWIRED

SENSOR FLUSH VALVE.

ELECTRIC WATER HEATER SCHEDULE

TAG

LOCATION BASIS OF DESIGN

TYPE

HEATING DATA

FLA MCA MOCP VOLTS PH REMARKSNAME NO. MANUFACTURER MODEL NO.

HEATING

CAPACITY (KW)

MAX TEMP RISE

(°F)

EWH-1 HANGAR BAY 101 EEMAX AP048480 EFD N4 INSTANT 48 16 58 72.5 175 480 3 1 - 3

EWH-2 HANGAR BAY 101 EEMAX AP048480 EFD N4 INSTANT 48 16 58 72.5 175 480 3 1 - 3

EWH-3 FUEL CELL TANK MAINTENANCE 126 EEMAX AP048480 EFD N4 INSTANT 48 16 58 72.5 175 480 3 1 - 3

NOTES:

1. PROVIDE WITH NON-FUSED DISCONNECT BY ELECTRICAL.

2. HEATER MUST COMPLY WITH ANSI Z358.1. PROVIDE WITH INTEGRAL RELIEF AND MIXING VALVE INSIDE EXPLOSION-PROOF NEMA 4 ENCLOSURE.

3. UNIT TO BE WALL-MOUNTED PER MANUFACTURER'S RECOMMENDATION.

NOTES:

1. AUTOMATIC DRIP DRAIN.

2. PROVIDE REFRIGERATED AIR DRYER. BASIS OF DESIGN: CHAMPION CRPC200

3. PROVIDE AIR FILTER. BASIS OF DESIGN: LT CAT RP200.

4. PROVIDE ASME RATED, SECTION VII, RECEIVER TANKS, STAINLESS STEEL TANK. BASIS OF DESIGN: QUINCY T400-200.

5. PROVIDE WITH MANUFACTURER STARTER.

6. DISCONNECT TO BE FURNISHED AND INSTALLED BY ELECTRICAL.

BREATHING AIR COMPRESSOR SCHEDULE

MARK LOCATION MODEL NO. TYPE

TOTAL AIR

(CFM)

PRESSURE

(PSIG)

RECIEVER

CAPACITY

(GAL)

ELECTRICAL DATA

WEIGHT

(LB) COMMENTS

MOTOR

(HP) VOLTAGE PHASE

BC-1 134 MECH CHAMPION L29 BREATHING AIR COMPRESSOR 173 125 400 40 480 3 1501 1, 4, 5, 6

BC-1b 134 MECH CHAMPION CRPC200 AIR DRYER 480 3 438 1, 2, 5, 6

BC-1c 134 MECH LT CAT RP200. AIR FILTER 115 1 125 1, 3

SCALE: N.T.S.C1

TANKLESS ELECTRIC WATER HEATER DETAIL

SCALE: N.T.S.A4

PIPE PENETRATION DETAIL

SCALE: N.T.S.A1

ESEW DETAIL

SCALE: N.T.S.A2

TANKLESS ELECTRIC WATER HEATER DETAIL

NOTES:

1. ALL EXPOSED PIPING AT PLUMBING FIXTURES SHALL BE CHROME PLATED WITH CHROME PLATED ESCUTCHEONS AT WALL PENETRATION.

2. PROVIDE CHROME PLATED BRASS P-TRAP AND SUPPLIES WITH STOP VALVES AT ALL SINKS, LAVATORIES AND DRINKING FOUNTAINS.

3. PROVIDE INSULATION FOR P-TRAP AND SUPPLIES AT ALL HANDICAPPED SINKS AND LAVATORIES.

4. CONNECTION SIZES SHOWN ARE MINIMUM SIZES.

5. SEE PLANS FOR COMMON VENT SIZES.

6. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.

Sheets
P-601 - PLUMBING SCHEDULES AND SCHEDULES

File details come from the government source that posted it. Updated .