1190113_TNANG_B113_FIRE-ADDENDUM 1-072622.pdf

PDF 587 KB Posted

Attached to
B113 Solicitation Federal contract opportunity
Solicitation number
W50S98
Issued by
Department of the Army Tennessee Army National Guard

About this file

This document package includes construction drawings and specifications for fire alarm and mass notification system work at Building 113 of the Tennessee Army National Guard facility in Alcoa, Tennessee. The scope of work includes installing a new fire alarm control panel, initiating devices such as pull stations and detectors, notification appliances including strobes and speakers, and associated wiring. Design and installation shall comply with UFC criteria for fire protection, mass notification, and aircraft hangars. General notes provide requirements for pathway survivability, synchronization of notification appliances, voltage drop and battery calculations, as-built documentation, and coordination with the existing fire alarm system. The drawings show the locations of new and relocated devices and equipment. Related federal contract opportunity W50S98 solicits offers to perform the fire alarm and mass notification work described in the construction documents along with an option to demolish Buildings 110 and 111. The solicitation is issued by the Department of the Army Tennessee Army National Guard.

View the file

Other files for this federal contract opportunity

Other files attached to B113 Solicitation, newest first.
File Type Posted
OF 1419 Abstract.pdf PDF
OF 1419 Abstract.pdf PDF
Sign in Sheet - 23 Aug 2022 10am.pdf PDF
B 113 As Built Drawings.pdf PDF
Demo 110_110 Drawings GC002 003 004 005.pdf PDF
BLDG 111 Asbestos Info.pdf PDF
05 40 00 Cold-formed Metal Framing 20220805.pdf PDF
Demo Drawings CS503-506.pdf PDF
W50S98-22-B-000100002.pdf PDF
P-601_REVISED.pdf PDF
REGISTER-upate 07292022.pdf PDF
1190113_TNANG_B113_ELEC-ADDENDUM 1-072622.pdf PDF
W50S98-22-B-000100001.pdf PDF
28 31 76 - updated.pdf PDF
Pre-Bid Sign in Sheet B113.pdf PDF
Pre-Bid Slides B113.pdf PDF
MTANG Demo 110 and 111 drawings.pdf PDF
Repair Building 113 Spec. Volume 2.pdf PDF
W50S98-22-B-0001 21 July 2022.pdf PDF
Repair Building 113 Spec. Volume 1.pdf PDF
Repair Building 113 Drawings.pdf PDF
Show all 21

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DESIGN AND INSTALLATION SHALL BE IN ACCORDANCE WITH UFC 1-200-01, "GENERAL BUILDING REQUIREMENTS", NOVEMBER 2018 CHANGE 2; UFC 3-310-04, "DESIGN: SEISMIC DESIGN FOR BUILDINGS", JUNE 2016 CHANGE 1; UFC 3-600-01, "FIRE PROTECTION ENGINEERING FOR FACILITIES", MARCH 2018 CHANGE 2; UFC 4-010-01, "DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS", FEBRUARY 2012 CHANGE 1; UFC 4-021-01 "DESIGN AND O&M: MASS NOTIFICATION SYSTEMS", JANUARY 2010 CHANGE 1;

UFC 4-211-01, "AIRCRAFT MAINTENANCE HANGARS" FOR AIR FORCE HANGAR, NOVEMBER 2017 CHANGE 1; INTERNATIONAL BUILDING CODE (IBC) 2015 EDITION; NFPA 1, "FIRE CODE", 2018 EDITION; NFPA 70, "NATIONAL ELECTRICAL CODE", 2017 EDITION;

NFPA 72, "NATIONAL FIRE ALARM AND SIGNALING CODE", 2019 EDITION; NFPA 101, "LIFE SAFETY CODE" 2018 EDITION; NFPA 241, "SAFEGUARDING CONSTRUCTION, ALTERATION, AND DEMOLITION OPERATIONS" 2019 EDITION; NFPA 409, "STANDARD ON AIRCRAFT HANGARS", 2016 EDITION. DEPARTMENT OF THE AIR FORCE’S “SUNDOWN POLICY FOR FOAM FIRE SUPPRESSION SYSTEMS”, CHANGE 1, DATED 13 MAY 2022. UFC SHALL TAKE PRECEDENCE OVER NFPA REQUIREMENTS.

FIRE ALARM FLOOR PLANS AND RISER DIAGRAM ARE DIAGRAMMATIC AND NOT INTENDED TO SHOW EACH AND EVERY COMPONENT, DEVICE, APPLIANCE, ETC. CONDUIT PATHWAYS AND INTERCONNECTIONS SHALL BE DETERMINED BY THE BUILDING FEATURES, NFPA 70, NFPA 72, SYSTEM MANUFACTURER REQUIREMENTS AND RECOMMENDATIONS.

CONTRACTOR SHALL VISIT JOB SITE PRIOR TO BID WITH THE PROJECT DOCUMENTS AND SPECIFICATIONS TO BECOME FAMILIAR WITH THE SITE AND SCOPE OF WORK. NOTIFY ENGINEER OF RECORD WITH ANY DISCREPANCIES OUTSIDE THIS DESIGN INTENT.

ANY CHANGE ORDER REQUEST AS A RESULT OF COORDINATION BETWEEN TRADES SHALL BE DENIED.

ADHERE TO AND OBTAIN ALL PERMITS, LICENSES, AND ALL LOCAL AND FEDERAL GOVERNMENT REQUIREMENTS.

DO NOT SCALE PLANS FOR THE PURPOSE OF ESTABLISHING DIMENSIONS. FIELD DIMENSION GOVERN.

FIRE STOP ALL PENETRATIONS OF SMOKE/FIRE PARTITIONS. FIRE STOPPING SHALL BE OF UL LISTED ASSEMBLY.

1.

2.

3.

4.

5.

6.

GENERAL NOTES

NEW ADDRESSABLE MANUAL PULL STATION,

MOUNT 42" - 48" AFF TO TOP OF HANDLE

EXISTING FIRE ALARM AND MASS

NOTIFICATION CONTROL PANEL TO REMAIN

NEW CONTROL MODULE

FMCP

F

CM

CONTRACTOR SHALL SUBMIT COMPLETE BATTERY CALCULATIONS, VOLTAGE DROP CALCULATIONS, MATERIAL DATA SHEETS, AND SHOP DRAWINGS TO OWNER'S TECHNICAL REPRESENTATIVE FOR REVIEW PRIOR TO COMMENCING ORDERING AND

INSTALLATION. FAILURE TO COMPLY IS AT THE RISK OF THE CONTRACTOR.

CONTRACTOR SHALL PROVIDE MINIMUM CIS SCORE OF 0.8 IN ALL AREAS IN ACCORDANCE WITH UFC 4-021-01. SEE

SPECIFICATION 28 31 76 FOR CIS SCORE EXCEPTIONS.

FIRE ALARM SIGNALS AND EMERGENCY COMMUNICATIONS SHALL TAKE PRECEDENCE OVER ALL OTHER SIGNALS, SUCH AS BUT

NOT LIMITED TO PUBLIC ADDRESS SYSTEMS.

ALL NOTIFICATION APPLIANCES CIRCUITS (NAC) SHALL PERFORM TO CLASS "B" AS DEFINED BY NFPA 72.

ALL SIGNALING LINE CIRCUITS (SLC) SHALL PERFORM TO CLASS "B" AS DEFINED BY NFPA 72.

ALL INDICATING DEVICE CIRCUITS SHALL PERFORM TO CLASS "B" AS DEFINED BY NFPA 72.

THE INSTALLATION OF WIRING BETWEEN THE FMCP AND RELAY MODULES OR APPLIANCES SHALL PERFORM TO CLASS "B" AS

DEFINED BY NFPA 72.

CONDUCTORS FOR THE FIRE ALARM SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 70. THE CONDUCTORS SHALL NOT BE INSTALLED WITH CONDUCTORS OF LIGHTING OR POWER SYSTEMS. THE SUM OF THE CROSS-AREA OF INDIVIDUAL CONDUCTORS SHALL NOT EXCEED 40% OF THE INTERIOR CROSS SECTION OF THE CONDUIT. NEW FIRE ALARM SYSTEM CONDUIT SHALL BE INSTALLED IN SEPARATE CONDUIT AND SHALL BE A MINIMUM 3/4" ELECTRICAL METALLIC TUBING.

WALL MOUNTED FIRE ALARM DEVICES IN UNFINISHED AREAS MAY BE SURFACED MOUNTED, THE CONDUIT MAY BE INSTALLED

EXPOSED ON WALLS AND ON CEILINGS.

IN FINISHED AREAS, WALL MOUNTED DEVICES SHALL BE FLUSH MOUNTED. THE CONDUIT SHALL BE INSTALLED CONCEALED IN

THE WALLS AND CEILINGS UNLESS REFERENCED AS CEILING MOUNTED.

FIRE ALARM CONTRACTOR SHALL COORDINATE WITH FIRE ALARM VENDOR FOR SYSTEM OPERATING INSTRUCTIONS AND WIRING

DIAGRAMS.

FIRE ALARM MANUAL PULL STATIONS AT DOOR OPENINGS SHALL BE WITHIN 5' - 0" HORIZONTALLY OF THE DOOR OPENING.

PROVIDE SYNCHRONIZATION FOR ALL NEW VISIBLE (STROBE) NOTIFICATION APPLIANCES WHERE THERE ARE MORE THAN TWO DEVICES IN THE SAME ROOM OR IN AN ADJACENT SPACE WITHIN THE FIELD OF VIEW TO COMPLY WITH THE REQUIREMENTS OF NFPA 72 (EXCLUDES CLASS 1 DIVISION 2 APPLIANCES IN HANGAR BAY AREA IF TECHNICAL LIMITATIONS EXIST).

PROVIDE SYNCHRONIZATION FOR ALL NEW AUDIBLE (SPEAKER) NOTIFICATION APPLIANCES WITHIN A NOTIFICATION ZONE TO

COMPLY WITH THE REQUIREMENTS OF NFPA 72.

PROVIDE TRANSIENT VOLT SURGE SUPPRESSION DEVICE WHERE CIRCUITS PENETRATE THE BUILDING ENVELOPE AND, FIRE ALARM EQUIPMENT SUPPLIED FROM THE BUILDING ELECTRICAL SYSTEM, (I.E DOOR HOLDERS, NAC BOOSTER PANELS, ETC), IN

ACCORDANCE WITH NFPA 70 AND NFPA 72 REQUIREMENTS.

STROBE FOR VISUAL FIRE ALARM/MASS NOTIFICATION APPLIANCES SHALL HAVE WHITE/ CLEAR LENS AND BE LABELED "ALERT" (EXCLUDES CLASS 1 DIVISION 2 APPLIANCES IN HANGAR BAY AREA IF TECHNICAL LIMITATIONS EXIST).

ALL FIRE ALARM PANELS AND EQUIPMENT SHALL BE GROUNDED IN ACCORDANCE WITH NFPA 70 ARTICLE 250 AND 800 WITH A

MAXIMUM OF 25 OHMS RESISTANCE.

CONTRACTOR SHALL PROVIDE A DOCUMENTATION CABINET AT THE SYSTEM CONTROL UNIT IN THE BUILDING WITH ALL REQUIRED DOCUMENTATION AND SOFTWARE REQUIRED BY NFPA 72 SECTIONS 7.7.2 AND 23.2.2.

REFER TO FIRE ALARM SYSTEM SPECIFICATION 28 31 76 FOR ADDITIONAL REQUIREMENTS AND INFORMATION.

CONTRACTOR SHALL PROVIDE PATHWAY SURVIVABILITY OF LEVEL 1 IN ACCORDANCE WITH NFPA 72.

DEMOLISH FIRE ALARM/RELEASING SYSTEM AS NEEDED TO PROVIDE COMPLIANT FIRE ALARM PROTECTION IN AND AROUND NEW/RENOVATED AREAS. FIRE ALARM CONTRACTOR IS RESPONSIBLE TO REPAIR IN KIND ANY DAMAGES THE BUILDING

SUSTAINS DURING DEMOLITION OF THE FIRE ALARM/RELEASING SYSTEM.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

NEW FIRE ALARM/MASS NOTIFICATION

CLEAR VISUAL STROBE. WALL MOUNT AT

80" AFF TO BOTTOM OF LENS OR 6" BELOW

CEILING, WHICHEVER IS LOWER AND NOT

GREATER THAN 96".

NEW FIRE ALARM/MASS NOTIFICATION

CLEAR VISUAL STROBE AND SPEAKER.

WALL MOUNT AT 80" AFF TO BOTTOM OF

LENS OR 6" BELOW CEILING, WHICHEVER IS

LOWER AND NOT GREATER THAN 96".

SURGE SUPPRESSOR

FIRE ALARM & MASS NOTIFICATION NOTES

SS

NEW LOW TEMPERATURE SENSORLT

FIRE ALARM & MASS NOTIFICATION LEGEND

CO CARBON MONOXIDE DETECTOR

IR

NEW DET-TRONICS X3301 FLAME DETECTOR

EAGLE QUANTUM PREMIER RELEASING PANELFSCP

BATTERY CABINETBATT

1 2 3 4 5

A

B

C

D

SHEET ID

P a rk w a y L a n e

S u it e

P e a c h tr e e C o rn e rs

G

A

P h o n e

-7

F a x

(6

-7

S

IZ

E

A N

S I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

D A

T E

D E

S C

R

IP

T

IO

N M

A R

K

/2

/2

:3

:2

P

M B

IM

/1

T N

A N

G R e p a ir

B ld g

F u e l C e ll/

T

N A

N G

B v

M P

F P

.r v t

FA001

100% REVISED

F

IR

E A

L A

R M

M

A S

S N

O T

IF

IC

A T

IO

N

G E

N E

R A

L N

O T

E S

A N

D L

E G

E N

D

R E

P A

IR

B

U

IL

D

IN

G

T

H T

E N

N E

S S

E E

A

IR

N A

T

IO

N A

L G

U A

R D

M c G

H E

E T

Y S

O N

A N

G B

A S

E A

L C

O A

T

E N

N E

S S

E E

T E

N N

E S

S E

E

A

IR

N A

T

IO

N A

L G

U A

R D

A L C

O A

T

E N

N E

S S

E E

J O

B N

O

B T

H

D B

N D

S

M

A R

C H

S O

L -X

X -X

-X X

X X

W L -1

-D

-0

X X

-X -X

X X

X G

L K

/2

/2

A

D D

E N

D U

M

REF.REF.REF.REF.

CM

CM

CM

CM

F

F

F F

F

F

CO

CO

F M

C P

IR

IR IR

IR

IRIR

B A

T T

LTLT

LT

1 1

MECH.

102A

LAUNDRY

109A

HANGAR BAY

MECH.

FUEL CELL TANK

MAINTENANCE

UNISEX

MECH.

ACCESSORIES

SUPERVISOR

CORRIDOR

COMM.

MECH.

114A

FUEL CELL

SUPERVISOR

MECH.

MECH.

BREAK ROOM

WELDING SHOP

OFFICE

MACHINE SHOP

BREAK ROOM

UNISEX

CORRIDOR

SUPPLY

CSO OFFICE

COMM.

FUEL CELL

OFFICE

CORR.

CORRIDOR

MEN'S LOCKER

ROOM

JANITOR

MEN'S

RESTROOM

WOMEN'S

RESTROOM

WOMEN'S

LOCKER ROOM

TOOL CRIB

CLOSET

NOSE BAY

101A

LTLT

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

A

B

C

D

E

F

G

H

J

K

L

M

OPEN SHOP

133A

ELEC.

VEST.

MACHINE SHOP

UNISEX

FSCP

SEE SHEET FA001 FOR GENERAL NOTES AND LEGEND.

FIRE ALARM/MASS NOTIFICATION AND FLAME

DETECTOR SYSTEM SHALL BE DESIGNED IN

ACCORDANCE WITH UFC 3-600-01, UFC 4-211-01, UFC

4-021-01, AND NFPA 72. THE ORDER OF PREFERENCE

OF CODE SHALL BE:

A. UFC 3-600-01

B. UFC 4-021-01

C. UFC 4-211-01

D. NFPA 72

ALL FIRE ALARM/MASS NOTIFICATION STROBES ARE

15 CANDELA UNLESS OTHERWISE NOTED.

ALL IN SCOPE AREAS OF THE BUILDING MUST

ACHIEVE A CIS SCORE OF 0.8. BUILDING OCCUPANTS

MUST BE ABLE TO WALK NOT MORE THAN 33 FEET TO

FIND A LOCATION WITH A CIS SCORE OF 0.8. AREAS

WITH HARD WALL, FLOOR, AND CEILING SURFACES

ARE PERMITTED TO HAVE CIS SCORE LESS THAN 0.8.

EXISTING FIRE ALARM AND OCCUPANT NOTIFICATION

SYSTEM IS TO REMAIN IN OPERATION AT ALL TIMES

TO THE FULLEST EXTENT POSSIBLE, UNTIL ALL

RELOCATED FIRE ALARM/MASS NOTIFICATION

APPLIANCES/DEVICES ARE RECONNECTED TO THE

FIRE ALARM/MASS NOTIFICATION SYSTEM AND NEW

SYSTEM IS OPERATIONAL AND ACCEPTANCE TESTING

IS COMPLETE.

FIRE ALARM/MASS NOTIFICATION DEVICES,

APPLIANCES, AND CONDUIT IN THE HANGAR BAY

SHALL BE LISTED FOR CLASS I DIVISION 2

HAZARDOUS AREAS UP TO 4'-0" ABOVE THE FINISHED

FLOOR.

GENERAL NOTES:

1.

2.

3.

4.

5.

6.

KEYNOTES:

EXISTING HIGH VOLUME LOW SPEED

DESTRATIFICATION FANS. CONTRACTOR SHALL

PROVIDE MEANS TO DE-ENERGIZE FANS UPON

ALARM ACTIVATION, IF NOT EXISTING.

INTERIOR WALLS ARE MODIFIED IN THIS AREA.

RECONFIGURE EXISTING FIRE ALARM

APPLIANCES/DEVICES TO PROVIDE CODE

COMPLIANT FIRE ALARM SIGNALING OR

NOTIFICATION. PROVIDE NEW

APPLIANCES/DEVICE IF NECESSARY.

PROVIDE NEW ADDRESSABLE FIRE ALARM PULL

STATION.

RELOCATE EXISTING KITCHEN RANGE HOOD

MONITORING DEVICES.

MOUNT FLAME DETECTORS AT THE LOCATIONS

SHOWN AT 10'+/-2' AFF USING Q9033 SWIVEL

MOUNT AND COLLAR ATTACHMENT. INSTALL 10'

FIELD OF VIEW LIMITERS ON ALL DETECTORS.

USE DET-TRONICS Q1201C LASER AIMER &

HOLDER FOR DETECTOR AIMING. VERIFY THE

LASER IS ZEROED WITH THE HOLDER ON THE

CENTRAL AXIS PRIOR TO AIMING.

FLAME DETECTORS ARE SET TO VERY HIGH

SENSITIVITY.

EAGLE QUANTUM PREMIER RELEASING PANEL TO

REPLACE EXISTING POTTER PFC-6075R

RELEASING PANEL.

NEW EAGLE QUANTUM PREMIER RELEASING

PANEL SECONDARY POWER BATTERY CABINET.

1.

2.

3.

4.

5.

6.

7.

8.

9.

EXISTING INITIATING DEVICES, NOTIFICATION

APPLIANCES, ASSOCIATED CIRCUITS AND

CONDUIT TO REMAIN.

LEGEND

SCALE: 3/32" = 1'-0"A1

FIRE ALARM & MASS NOTIFICATION PLAN

SCALE: = 1'-0"3/32"

0 8 16 248

KEY

# KEYNOTE DESCRIPTION

1 2 3 4 5

A

B

C

D

SHEET ID

P a rk w a y L a n e

S u it e

P e a c h tr e e C o rn e rs

G

A

P h o n e

-7

F a x

(6

-7

S

IZ

E

A N

S I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

D A

T E

D E

S C

R

IP

T

IO

N M

A R

K

/2

/2

:3

:3

P

M B

IM

/1

T N

A N

G R e p a ir

B ld g

F u e l C e ll/

T

N A

N G

B v

M P

F P

.r v t

FA101

100% REVISED

F

IR

E A

L A

R M

M

A S

S N

O T

IF

IC

A T

IO

N

P L A

N

R E

P A

IR

B

U

IL

D

IN

G

T

H T

E N

N E

S S

E E

A

IR

N A

T

IO

N A

L G

U A

R D

M c G

H E

E T

Y S

O N

A N

G B

A S

E A

L C

O A

T

E N

N E

S S

E E

T E

N N

E S

S E

E

A

IR

N A

T

IO

N A

L G

U A

R D

A L C

O A

T

E N

N E

S S

E E

J O

B N

O

B T

H

D B

N D

S

M

A R

C H

S O

L -X

X -X

-X X

X X

W L -1

-D

-0

X X

-X -X

X X

X G

L K

D A

T E

D E

S C

R

IP

T

IO

N M

A R

K

/2

/2

A

D D

E N

D U

M

FMCP FIRE SAFETY

A C

T U

A T

E A

U D

IO

V

IS

U

L

S U

P E

R V

IS

O

R Y

I N

D

IC

A T

IO

N

D E

V

IC

E

A C

T U

A T

E A

U D

IO

V

IS

U

A L A

L A

R M

IN

D

IC

A T

O R

D E

V

IC

E S

S H

U T

D O

W N

E S

T R

A T

IF

IC

A T

IO

N

F A

N S

S H

U T

D O

W N

A L L H

V A

C U

N

IT

S

U N

L O

C K

E X

IT

S

A B C D E F G H I

F1 MANUAL PULL STATION

SPRINKLER CONTROL VALVE

FIRE ALARMS

SUPERVISORY SIGNALS

X

SYSTEM INPUTS

S1

F2

T R

A N

S M

IT

A

L A

R M

S

IG

N A

L T

O

M O

T E

S T

A T

IO

N

T R

A N

S M

IT

S

U P

E R

V

IS

O

Y

S

IG

N A

L T

O R

E M

O T

E S

T A

T

IO

N

A L E

R T

S T

R O

B E

T H

R O

U G

H O

U

H E

B U

IL

D

IN

G

C

L E

A R

F

IR

E A

L A

R M

E V

A C

U A

T

IO

N M

E S

S A

G

H R

O U

G H

O U

T B

U

IL

D

IN

G

REMOTE

STATION

EVAC

SIGNALS

SYSTEM OUTPUTS

SMOKE DETECTOR

WATER FLOW SWITCH

X

X

X

X

X

X

X

X

X

X X

S2

S3

LOW TEMPERATURE SENSOR

X

X X

X

TEMPERATURE RETURN TO NORMAL X X

F3 X X X X X

GENERAL TROUBLE CONDITION

TROUBLE SIGNALS

T1 X

T2 GENERAL TROUBLE CONDITION SIGNAL FROM FSCP X

F4 ALARM SIGNAL FROM FSCP X X

S4 SUPERVISORY SIGNAL FROM FSCP X X

A C

T U

A T

E A

U D

IO

V

IS

U

A L T

R O

U B

IC

A T

IO

N

D E

V

IC

E

X

X

T R

A N

S M

IT

T

R O

U B

L E

S

IG

N

O

R E

M O

T E

S T

A T

IO

N

J K

X X

EXISTING FIRE

ALARM/MASS

NOTIFICATION

CONTROL

PANEL (FMCP)

S

BATTERIES

SS

FATR

SIGNALING LINE CIRCUIT (SLC)

NOTIFICATION APPLIANCE

CIRCUIT (NAC)

SPEAKER CIRCUIT

120 VAC

F

SEE SHEET FA001 FOR GENERAL NOTES AND LEGEND.

CONTRACTOR SHALL VERIFY THAT THE EXISTING SIMPLEX 4100 ES FIRE ALARM CONTROL PANEL HAS THE

CAPACITY FOR THE NEW APPLIANCES AND DEVICES.

CONTRACTOR SHALL ENSURE THAT THE NEW FIRE ALARM/MASS NOTIFICATION APPLIANCES/DEVICES ARE

COMPATIBLE WITH THE EXISTING SIMPLEX 4100 ES CONTROL PANEL.

GENERAL NOTES

1.

2.

3.

BREAKER

POWER

PANEL

POWER

120 VAC SS

SS

BREAKER SERVING THE FMCP AND FSCP SHALL HAVE A RED MARKING PER NFPA 72 SECTION 10.6.2.3 AND

10.6.5.2.4 AND PROVIDED WITH A NON-SWEEP DEVICE (LOCK) PER NFPA 72; SECTION 10.6.5.4 IN ADDITION, MEET THE REQUIREMENTS OF NFPA 72; SECTION 10.6.5.2.2, 10.6.5.2.5, AND 10.6.5.3. PROVIDE IF NOT EXISTING.

FMCP AND FSCP SHALL INDICATE THE LOCATION AND IDENTIFICATION OF THE POWER PANEL WHERE THE

POWER BREAKER IS LOCATED PER NFPA 72 REQUIREMENTS. PROVIDE IF NOT EXISTING.

NOTE: DASHED LINE INDICATES EXISTING EQUIPMENT TO BE REMAIN

LT CM

DESTRATIFICATION

FANS

KEYNOTES:

1.

2.

TO FSCP

FSCP NOTIFICATION

A C

T U

A T

E A

U D

IO

V

IS

U

A L T

R O

U B

L E

I N

D

IC

A T

IO

N

D E

V

IC

E

A C

T U

A T

E A

U D

IO

V

IS

U

A L A

L A

R M

I N

D

IC

A T

O R

D E

V

IC

E S

A C

T U

A T

E A

U D

IO

V

IS

U

A L C

O M

M O

N S

U P

E R

V

IS

O

Y

IC

A

T O

R

G E

N E

R A

L A

L A

R M

S

IG

N A

L T

O E

X

IS

T

IN

G F

M C

P A

M

O T

E S

T A

T

IO

N

G E

N E

R A

L T

R O

U B

L E

S

IG

N A

L T

O E

X

IS

T

IN

G F

M C

P A

M

O T

E S

T A

T

IO

N

A B C D E F

F1

COMMON SUPERVISORY

ALARM CONDITIONS

SUPERVISORY CONDITIONS

TROUBLE CONDITIONS

COMMON TROUBLE

X

SYSTEM INPUTS

S1

T1

SYSTEM OUTPUTS

ONE OPTICAL FLAME DETECTOR

X

X X

X

G E

N E

R A

L S

U P

E R

V

IS

O R

Y S

IG

N

A L T

O F

M C

P A

M

O T

E S

T A

T

IO

N

X

FLAME

DETECTOR

SYSTEM

CONTROL

PANEL

SIGNALING LINE CIRCUIT (SLC)

IR

TO FMCP

MM MM

BATTERIES

IR

SS120 VAC

BREAKER

POWER

PANEL

POWER

1 2 3 4 5

A

B

C

D

SHEET ID

P a rk w a y L a n e

S u it e

P e a c h tr e e C o rn e rs

G

A

P h o n e

-7

F a x

(6

-7

S

IZ

E

A N

S I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

D A

T E

D E

S C

R

IP

T

IO

N M

A R

K

/2

/2

:3

:3

P

M B

IM

/1

T N

A N

G R e p a ir

B ld g

F u e l C e ll/

T

N A

N G

B v

M P

F P

.r v t

FA501

100% REVISED

F

IR

E A

L A

R M

M

A S

S N

O T

IF

IC

A T

IO

N

D E

T A

IL

S

R E

P A

IR

B

U

IL

D

IN

G

T

H T

E N

N E

S S

E E

A

IR

N A

T

IO

N A

L G

U A

R D

M c G

H E

E T

Y S

O N

A N

G B

A S

E A

L C

O A

T

E N

N E

S S

E E

T E

N N

E S

S E

E

A

IR

N A

T

IO

N A

L G

U A

R D

A L C

O A

T

E N

N E

S S

E E

J O

B N

O

B T

H

D B

N D

S

M

A R

C H

S O

L -X

X -X

-X X

X X

W L -1

-D

-0

X X

-X -X

X X

X G

L K

SCALE: N.T.S.A3

EXISTING FMCP FIRE ALARM/MASS NOT. OPERATIONAL MATRIX

NOTE 1: THIS MATRIX SHOWS THE MODIFICATIONS NEEDED FOR THE SYSTEM. IT DOES NOT SHOW CURRENT

OPERATIONS.

NOTE 2: IT IS THE FIRE ALARM CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXISTING SYSTEM'S SEQUENCE OF OPERATIONS FEATURES AND COMPLY WITH EXISTING FEATURES. AT MINIMUM, THE NEW APPLIANCES AND DEVICES

SHALL PERFORM AS INDICATED ABOVE.

SCALE: N.T.S.C1

FMCP RISER DIAGRAM

KEY

# KEYNOTE DESCRIPTION

SCALE: N.T.S.A1

FSCP OPERATIONAL MATRIX

SCALE: N.T.S.B1

FSCP RISER DIAGRAM

/2

/2

A

D D

E N

D U

M

Sheets
F-001 - FIRE PROTECTION GENERAL NOTES AND LEGEND
F-101 - FIRE PROTECTION PLAN
FA001 - FIRE ALARM & MASS NOTIFICATION GENERAL NOTES AND LEGEND
FA101 - FIRE ALARM & MASS NOTIFICATION PLAN
FA501 - FIRE ALARM & MASS NOTIFICATION DETAILS
FD101 - FIRE PROTECTION DEMOLITION PLAN

File details come from the government source that posted it. Updated .