TS101 - TELECOMMUNICATIONS SITE PLAN.pdf

PDF 492 KB Posted

Attached to
Entry Control Facility Federal contract opportunity
Solicitation number
W50S8N21B0001
Issued by
Department of the Army National Guard

About this file

This solicitation is for a construction contract to build a new Entry Control Facility complex at Hancock Field Air National Guard Base in New York. The project scope includes constructing a gate house, guard booth, vehicle canopies, pavements, fencing, gates, site lighting, and drainage. An active denial barrier and demolition of the existing facility are also included. The contract is set aside for Service Disabled Veteran Owned Small Businesses with revenues under $39.5 million. The project magnitude is estimated between $1 million to $5 million. The pre-bid conference will be held on-site. Bids are due by the date specified in solicitation amendment 003 and must include pricing for all items to be considered. The Army National Guard is the issuing agency. Award will be made based on price to the responsible bidder offering the most advantage to the government.

View the file

Other files for this federal contract opportunity

Other files attached to Entry Control Facility, newest first.
File Type Posted
HAAW139030 Bid Abstract.pdf PDF
W50S8N21B00010003.pdf PDF
RFI Tracker-HAAW139030 ECP Facility 11-5.pdf PDF
ES101 - ELECTRICAL SITE PLAN - SOUTH.pdf PDF
32 16 19_Addendum003.pdf PDF
Tax Form NY ST120_1_fill_in.pdf PDF
T-111 - ELECTRONIC SECURITY SYSTEM PLAN.pdf PDF
T-502 - TELLECOMMUNICATIONS DETAILS.pdf PDF
34 71 13.19_Addendum003.pdf PDF
C-501_Addendum003.pdf PDF
CD102_Addendum003.pdf PDF
CU101_Addendum003.pdf PDF
E-612 - ELECTRICAL SCHEDULES.pdf PDF
W50S8N21B00010002.pdf PDF
W50S8N21B00010001.pdf PDF
32 12 16.16_Revised2021-10-21.pdf PDF
1200535 NYANG Syracuse ECF - REVISED CIVIL DWGS_2021-10-21.pdf PDF
1200535_NYANG_SYR_ADDENDUM 0001_v19.pdf PDF
Section 08 71 00 Spec Edits_ADDENDUM 0001.pdf PDF
RFI Tracker-HAAW139030 ECP Facility 10-26-2021.pdf PDF
Site Visit Sign In Sheet.pdf PDF
HAAW139030 Site Visit Slides.pptx PPTX presentation
1200535_NYANG_SYR Combined Drawings.pdf PDF
W50S8N21B0001 IFB Entry Control Facility.pdf PDF
SOW HAAW152023.docx DOCX document
B3 Specs Vol. 1.pdf PDF
B3 Specs Vol. 2.pdf PDF
1200535_NYANG_SYR Combined Drawings (2).pdf PDF
Show all 28

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EM

B-174

A R

V

15'+ AFG

15'+ AFG

15'+ AFG

15'+ AFG

15'+ AFG

15'+ AFG

15'+ AFG

15'+ AFG

UC

UC

UC

MH C-23

TSP

B-174

SCALE: 1" = T

R

U E

N

1 2 3 4 5

A

B

C

D

SHEET ID

P a rk w a y L a n e

S u it e

P e a c h tr e e C o rn e rs

G

A

P h o n e

-7

F a x

(6

-7

S

IZ

E

A N

S I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

PLAN

NORTH

0 50 10050

50'-0"

ORIGINAL SHEET SIZE: 22" X 34"

M A

/2

/2

:5

:5

A

M B

IM

/1

N

Y A

N G

S Y

R E n tr y C o n tr o l/ N

Y A

N G

S

Y R

M

E P

F

P v .r v t

TS101

B3 - 100% SUBMITTAL

T E

L E

C O

M M

U N

IC

A

T

IO

N S

S

IT

E P

L A

N

C O

N S

T R

U C

T E

N T

R Y

C O

N T

R O

L F

A C

IL

IT

Y T

H A

T T

A C

K W

IN

G

H A

N C

O C

K F

IE

L D

A N

G B

M A

T T

Y D

A L E

N

E W

Y O

R K

N E

W Y

O R

K

A

IR

N A

T

IO

N A

L G

U A

R D

H A

N C

O C

K F

IE

L D

A N

G B

N

E W

Y O

R K

J O

B N

O

D T

B

D T

B

T E

H

J

U L Y

W P

Q F

X X

-X -X

X X

SHEET NOTES:

1. REFER TO T-001 FOR TELECOMMUNICATIONS GENERAL

NOTES, ABBREVIATIONS & LEGEND.

2. REFER TO T-502 FOR CCTV RISER DIAGRAM.

3. PROVIDE SURGE PROTECTIONS DEVICES (SPD) FOR

COMMUNICATION EQUIPMENT AND SPECIALIZED ELECTRICAL

EQUIPMENT SUCH AS DETECTION SYSTEMS (ANTENNAS),

EXTERIOR SECURITY SYSTEMS (EXTERIOR CAMERAS) AND

MASS NOTIFICATIONS SYSTEMS (MNS). SPDS SHALL BE

UL1283 AND UL1449 RATED, AND USED WHERE APPLICABLE.

KEYNOTES:

1. APPROXIMATE LOCATION OF EXISTING

TELECOMMUNICATIONS MANHOLE.

2. PROVIDE (1) 4" RIGID STEEL CONDUIT FROM HANDHOLE TO

GUARD BOOTH FOR COMMUNICATIONS. ROUTE CAT6

CABLES IN (1) THREE CELL, 1" INCH FABRIC-MESH

INNERDUCT IN THE NEW 4" INCH CONDUIT.

3. BID OPTION 3: REPULL (1) 12 STRAND SM FIBER FROM

BUILDING B-627 IN 1-1/2" RIGID STEEL CONDUIT TO

RELOCATED BASE MARQUEE SIGN.

4. PROVIDE 1" RIGID STEEL CONDUIT FOR COMMUNICATION

CABLES ROUTED TO THE OVERWATCH POST GOOSENECK

FOR DURESS ALARM ENUNCIATOR AND EMERGENCY FAST

OPERATION CONTROLS.

5. UNDERGROUND COMMUNICATIONS DUCTBANK. REFER TO

DETAIL B1/T-501. COORDINATE WITH CIVIL SITE PLAN TO

AVOID CONFLICTS WITH SITE UTILITIES. PROVIDE (1) 24-

STRAND SM FIBER CABLE AND (2) THREE CELL, THREE

INCH FABRIC-MESH INNERDUCT IN ONE OF THE NEW FOUR

INCH DUCTS AND ROUTE TO THE GATE HOUSE THROUGH

THE INNERDUCT.

6. PROVIDE A FIBER TO ETHERNET MEDIA CONVERTER AT

EACH POLE MOUNTED CAMERA LOCATION. PROVIDE TWO-

STRAND SM FIBER LC TO EACH CAMERA LOCATION IN 3/4"

RIGID STEEL CONDUIT. CAMERAS AND ACCESSORIES

SHALL BE CAPABLE OF OPERATING IN A TEMPERATURE

RANGE OF -58° F TO 122° F. BASIS OF DESIGN: AXIS

COMMUNICATIONS. REFER TO A4/T-501 FOR CAMERA

MOUNTING DETAIL.

7. EXISTING TRAFFIC SIGN POLE AND CAMERAS ARE

EXISTING TO REMAIN. CONNECT EXISTING CAMERAS TO

THE NEW GATE HOUSE CCTV SWITCH.

8. PROVIDE (1) CONTRACTOR FURNISHED CONTRACTOR

INSTALLED 24 SM FIBER OPTIC CABLE IN THE EXISTING

COMMUNICATION CONDUIT FROM B-174 TO THE NEW GATE

HOUSE.

9. PROVIDE LC PATCH PANELS IN THE B-174 COMMUNICATION

CLOSET TO TERMINATE THE NEW 24 SM FIBER OPTIC

CABLE. ALL SPLICES AND TERMINATIONS SHALL BE MADE

USING FUSION SPLICING.

10. PROVIDE 3/4" RIGID STEEL CONDUIT FOR AVB LOW

VOLTAGE CONTROL WIRING.

11. EXISTING COMMUNICATION CONDUIT.

12. BID OPTION 2: PROVIDE 3/4" RIGID STEEL CONDUIT FOR

MOTORIZED GATE OPERATOR CONTROL WIRING.

COORDINATE THE CONTRACTOR PROVIDED CONTROL

WIRE REQUIREMENT WITH MANUFACTURER PRIOR TO

INSTALLATION.

13. PROVIDE (2) 4" RIGID STEEL CONDUITS FROM GATE HOUSE

TO HANDHOLE FOR COMMUNICATIONS. ROUTE CAT6

CABLES IN (4) THREE CELL, 1" INCH FABRIC-MESH

INNERDUCT IN ONE OF THE NEW 4" INCH CONDUITS. THE

OTHER 4" CONDUIT WILL BE SPARE.

14. PROVIDE 3/4" RIGID STEEL CONDUIT FOR AVB WRONG

WAY DETECTION CONTROL WIRING.

SCALE: 1" = 50'-0"A1

TELECOMMUNICATIONS SITE PLAN

BID OPTION 3: RELOCATED BASE

MARQUEE

C1

C2

C3

C4

C5

C6 C7

C8

NEW TELECOM HANDOLE

M A

R K

D E

S C

R

IP

T I O

N D

A T

E

A

D D

E N

D U

M

R E

V

IS

E D

D R

A W

I N G

S /2

/2

Sheets
TS101 - TELECOMMUNICATIONS SITE PLAN

File details come from the government source that posted it. Updated .