T-502 - TELLECOMMUNICATIONS DETAILS.pdf

PDF 295 KB Posted

Attached to
Entry Control Facility Federal contract opportunity
Solicitation number
W50S8N21B0001
Issued by
Department of the Army National Guard

About this file

This document package includes a solicitation for a construction contract and supporting technical drawings. The solicitation is for Project No. HAAW139030 to construct a new Entry Control Facility complex for the Department of the Army National Guard. The scope of work includes building a gate house, guard booth, vehicle canopies, pavements, fencing, gates, active denial barriers, site lighting, drainage, and demolition of the existing facility. The project magnitude is between $1 million and $5 million. The solicitation is set aside for Service Disabled Veteran Owned Small Businesses only. The NAICS code is 236220 with a $39.5 million average annual revenue size standard. The pre-bid conference and site visit are encouraged. Bids must conform to the invitation and be submitted by the response date specified. Award will be made based on price to the responsible bidder that is most advantageous to the government. The supporting technical drawings provide construction details for the telecommunications aspects of the project.

View the file

Other files for this federal contract opportunity

Other files attached to Entry Control Facility, newest first.
File Type Posted
HAAW139030 Bid Abstract.pdf PDF
W50S8N21B00010003.pdf PDF
RFI Tracker-HAAW139030 ECP Facility 11-5.pdf PDF
ES101 - ELECTRICAL SITE PLAN - SOUTH.pdf PDF
32 16 19_Addendum003.pdf PDF
C-501_Addendum003.pdf PDF
CD102_Addendum003.pdf PDF
Tax Form NY ST120_1_fill_in.pdf PDF
T-111 - ELECTRONIC SECURITY SYSTEM PLAN.pdf PDF
34 71 13.19_Addendum003.pdf PDF
CU101_Addendum003.pdf PDF
TS101 - TELECOMMUNICATIONS SITE PLAN.pdf PDF
E-612 - ELECTRICAL SCHEDULES.pdf PDF
W50S8N21B00010002.pdf PDF
W50S8N21B00010001.pdf PDF
32 12 16.16_Revised2021-10-21.pdf PDF
1200535 NYANG Syracuse ECF - REVISED CIVIL DWGS_2021-10-21.pdf PDF
1200535_NYANG_SYR_ADDENDUM 0001_v19.pdf PDF
Section 08 71 00 Spec Edits_ADDENDUM 0001.pdf PDF
RFI Tracker-HAAW139030 ECP Facility 10-26-2021.pdf PDF
Site Visit Sign In Sheet.pdf PDF
HAAW139030 Site Visit Slides.pptx PPTX presentation
1200535_NYANG_SYR Combined Drawings.pdf PDF
W50S8N21B0001 IFB Entry Control Facility.pdf PDF
SOW HAAW152023.docx DOCX document
B3 Specs Vol. 1.pdf PDF
B3 Specs Vol. 2.pdf PDF
1200535_NYANG_SYR Combined Drawings (2).pdf PDF
Show all 28

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TYPICAL TMGB DRILLED HOLE DIMENSIONS

COMPRESSION

CONNECTOR W/

VIEWING WINDOW

1 1/2" NOMINAL

INSULATOR

STAINLESS STEEL

STANDOFF BRACKET

ELECTRO-TIN PLATED

COPPER GROUND BAR

STAINLESS STEEL HARDWARE

TYPE

TMGB 20"

WIDTH

4"

THICKNESS

1/4" 24 3

MINIMUM

LENGTH

MINIMUM NUMBER OF

PAIRS OF 5/16"

DIAMETER HOLES

MINIMUM NUMBER OF

PAIRS OF 7/16"

DIAMETER HOLES

TELECOMMUNICATIONS MAIN GROUND BAR (TMGB)

SCHEDULE ANSI-J-STD-607-A

2"

1 1/8" TYP

5/16" DIAMETER HOLE PAIR (TYP)

7/16" DIAMETER HOLE PAIR (TYP)

/8

/8

GFGI CCTV MONITOR IN

CONTROL ROOM 100

120VAC

GUARD BOOTH

EXTERIOR

WALL MOUNT C9

TO TMGB

#6G

EXTERIOR PTZ

POLE MOUNT C8

EXTERIOR PTZ

POLE MOUNT C7

EXTERIOR PTZ

POLE MOUNT C6

EXTERIOR PTZ

POLE MOUNT C5

EXTERIOR PTZ

POLE MOUNT C4

EXTERIOR PTZ

POLE MOUNT C3

EXTERIOR PTZ

POLE MOUNT C2

EXTERIOR PTZ

POLE MOUNT C1

CANOPY COLUMN

MOUNT C10

CANOPY COLUMN

MOUNT C11

CANOPY COLUMN

MOUNT C12

CANOPY COLUMN

MOUNT C13

GATE HOUSE

EXTERIOR

WALL MOUNT C14

CANOPY COLUMN

WALL MOUNT C15

1RU 24-CHANNEL NETWORK

VIDEO RECORDER/

POE SWITCH

UPS - 12

UPS - 2

UPS - 13

GATE HOUSE

EXTERIOR

WALL MOUNT C16

(TYP.)

(TYP.)

GATE HOUSE PTZ

WALL MOUNT C17

GATE HOUSE PTZ

WALL MOUNT C18

1RU MEDIA CONVERTER

CHASSIS

TO FIBER OPTIC PATCH

PANEL IN WORKSTATION 101

TELECOM CABINET

SHEET NOTES:

SCALE: N.T.S.A1

TMGB GROUND BAR DETAIL

1. REFER TO T-001 FOR TELECOMMUNICATIONS GENERAL

NOTES, ABBREVIATIONS & LEGEND.

1 2 3 4 5

A

B

C

D

SHEET ID

P a rk w a y L a n e

S u it e

P e a c h tr e e C o rn e rs

G

A

P h o n e

-7

F a x

(6

-7

S

IZ

E

A N

S I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

ORIGINAL SHEET SIZE: 22" X 34"

M A

/4

/2

:3 :1

A

M B

IM

/1

N

Y A

N G

S Y

R E n tr y C o n tr o l/ N

Y A

N G

S

Y R

M

E P

F

P v .r v t

T-502

B3 - 100% SUBMITTAL

T E

L E

C O

M M

U N

IC

A

T

IO

N S

D E

T A

IL

S

C O

N S

T R

U C

T E

N T

R Y

C O

N T

R O

L F

A C

IL

IT

Y T

H A

T T

A C

K W

IN

G

H A

N C

O C

K F

IE

L D

A N

G B

M A

T T

Y D

A L E

N

E W

Y O

R K

N E

W Y

O R

K

A

IR

N A

T

IO

N A

L G

U A

R D

H A

N C

O C

K F

IE

L D

A N

G B

N

E W

Y O

R K

J O

B N

O

D T

B

D T

B

T E

H

J

U L Y

W P

Q F

X X

-X -X

X X

SCALE: N.T.S.A2

CCTV RISER DIAGRAM

KEYNOTES:

1. OUTDOOR RATED, CMX, UV RESISTANT CAT 6 CABLE SHALL BE

ROUTED THROUGH THE 4" TELECOMMUNICATIONS CONDUIT TO

THE HANDHOLE AND THEN INDIVIDUALLY ROUTED IN 3/4" RIGID

STEEL CONDUIT.

2. TWO-STRAND SM DUPLEX LC IN 3/4" RIGID STEEL CONDUIT TO

LIGHT POLE.

3. MEDIA CONVERTOR.

4. CAT 6 CABLE.

5. OUTDOOR RATED, CMX, UV RESISTANT CAT 6 CABLE SHALL BE

ROUTED IN 3/4" RIGID STEEL CONDUIT.

M A

R K

D E

S C

R

IP

T I O

N D

A T

E

A

D D

E N

D U

M

R E

V

IS

E D

D R

A W

I N G

S /0

/2

Sheets
T-502 - TELECOMMUNICATIONS DETAILS

File details come from the government source that posted it. Updated .