ES101 - ELECTRICAL SITE PLAN - SOUTH.pdf

PDF 555 KB Posted

Attached to
Entry Control Facility Federal contract opportunity
Solicitation number
W50S8N21B0001
Issued by
Department of the Army National Guard

About this file

This solicitation package includes plans and specifications for the construction of a new Entry Control Facility complex for the Department of the Army National Guard. The project scope encompasses constructing a gate house, guard booth, vehicle canopies, pavements, fencing, active denial barriers, site lighting, drainage, and demolition of the existing facility. The solicitation is set aside as a total Service Disabled Veteran Owned Small Business and has a project magnitude between $1-5 million. The pre-bid conference and site visit are highly encouraged. Bids are due by the date specified in Section 00100 and must include pricing for all items. Award will be made based on price to the responsible bidder whose conforming bid is most advantageous to the government.

View the file

Other files for this federal contract opportunity

Other files attached to Entry Control Facility, newest first.
File Type Posted
HAAW139030 Bid Abstract.pdf PDF
CU101_Addendum003.pdf PDF
TS101 - TELECOMMUNICATIONS SITE PLAN.pdf PDF
E-612 - ELECTRICAL SCHEDULES.pdf PDF
C-501_Addendum003.pdf PDF
CD102_Addendum003.pdf PDF
W50S8N21B00010003.pdf PDF
RFI Tracker-HAAW139030 ECP Facility 11-5.pdf PDF
32 16 19_Addendum003.pdf PDF
Tax Form NY ST120_1_fill_in.pdf PDF
T-111 - ELECTRONIC SECURITY SYSTEM PLAN.pdf PDF
T-502 - TELLECOMMUNICATIONS DETAILS.pdf PDF
34 71 13.19_Addendum003.pdf PDF
W50S8N21B00010002.pdf PDF
Section 08 71 00 Spec Edits_ADDENDUM 0001.pdf PDF
RFI Tracker-HAAW139030 ECP Facility 10-26-2021.pdf PDF
W50S8N21B00010001.pdf PDF
32 12 16.16_Revised2021-10-21.pdf PDF
1200535 NYANG Syracuse ECF - REVISED CIVIL DWGS_2021-10-21.pdf PDF
1200535_NYANG_SYR_ADDENDUM 0001_v19.pdf PDF
HAAW139030 Site Visit Slides.pptx PPTX presentation
Site Visit Sign In Sheet.pdf PDF
1200535_NYANG_SYR Combined Drawings.pdf PDF
B3 Specs Vol. 1.pdf PDF
B3 Specs Vol. 2.pdf PDF
1200535_NYANG_SYR Combined Drawings (2).pdf PDF
SOW HAAW152023.docx DOCX document
W50S8N21B0001 IFB Entry Control Facility.pdf PDF
Show all 28

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

J

J

J

PL1

PL1

PL3

PL3

PL3

PL2

PL2

PL2

PL1

PL2

PL2

PL4

PL4

PL4

UE

MATCH LINE

SEE A1/ES102

NP21A-35,37

NP21A-39,41

UP2A-11

UP2A-10

NP21A-16,18

TSP

NP21A-25,27,29

UE

UE

UE

WP

UE

7 (TYP.)

NP21B-10

NP21A-20

NP21A-22

T R

U E

N

1 2 3 4 5

A

B

C

D

SHEET ID

P a rk w a y L a n e

S u it e

P e a c h tr e e C o rn e rs

G

A

P h o n e

-7

F a x

(6

-7

S

IZ

E

A N

S I D

F

IL

E N

A M

E

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

IS

S

U E

D A

T E

S O

L

IC

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

PLAN

NORTH

ORIGINAL SHEET SIZE: 22" X 34"

M A

/2

/2

:2 :2

P

M B

IM

/1

N

Y A

N G

S Y

R E n tr y C o n tr o l/ N

Y A

N G

S

Y R

M

E P

F

P v .r v t

ES101

B3 - 100% SUBMITTAL

E L E

C T

R

IC

A L S

IT

E

P L A

N

S O

U T

H

C O

N S

T R

U C

T E

N T

R Y

C O

N T

R O

L F

A C

IL

IT

Y T

H A

T T

A C

K W

IN

G

H A

N C

O C

K F

IE

L D

A N

G B

M A

T T

Y D

A L E

N

E W

Y O

R K

N E

W Y

O R

K

A

IR

N A

T

IO

N A

L G

U A

R D

H A

N C

O C

K F

IE

L D

A N

G B

N

E W

Y O

R K

J O

B N

O

D T

B

D T

B

T E

H

J

U L Y

W P

Q F

X X

-X -X

X X

SHEET NOTES:

1. REFER TO E-001 & E-002 FOR ELECTRICAL GENERAL NOTES,

ABBREVIATIONS & LEGEND.

2. REFER TO E-611 FOR LUMINAIRE SCHEDULE.

3. REFER TO E-600 & E-601 FOR CONDUIT AND CONDUCTOR SIZES

NOT INDICATED ON THE PLAN.

4. PROVIDE GROUNDING FOR NEW FENCING. REFER TO A4/E-503

FOR FENCE GROUNDING DETAIL.

KEYNOTES:

1. TO NEW BUILDING 150kVA PAD MOUNT UTILITY TRANSFORMER.

REFER TO A1/E-503 FOR DETAIL.

2. GFGI PORTABLE GENERATOR LOCATION.

3. PROVIDE A FREE-STANDING NEMA 3R 4kVA LIGHTING INVERTER

WITH FLOOR MOUNTING BRACKETS. REFER TO DETAIL B2/E-505

FOR MORE INFORMATION.

4. UNDERGROUND ELECTRICAL DUCTBANK WITH (2) 4" DUCTBANK.

REFER TO DETAIL A1/E-502. COORDINATE WITH CIVIL SITE PLAN

TO AVOID CONFLICTS WITH SITE UTILITIES.

5. UNDERGROUND CONDUIT AND CONDUCTORS TO GUARD SHACK

PANEL 'NP1'. REFER TO E-601 FOR ADDITIONAL INFORMATION.

6. BID OPTION 2: PROVIDE 208V/1-PHASE POWER TO MOTORIZED

GATE OPERATOR. COORDINATE EXACT LOCATION WITH CIVIL

PLANS.

7. ANSI TIER 15 RATED ELECTRICAL HANDHOLE. REFER TO

A2/E-502 FOR HANDHOLE DETAIL. COORDINATE WITH CIVIL SITE

PLAN TO AVOID CONFLICTS WITH SITE UTILITIES.

8. MOUNT 120V GFCI WP DUPLEX RECEPTACLE 15'-0" ABOVE

FINISHED GRADE FOR CCTV CAMERA POWER.

9. PROVIDE 2" RIGID GALVANIZED STEEL CONDUIT FOR POWER

TO ACTIVE VEHICLE BARRIER.

10. PROVIDE 208V/3-PHASE POWER TO LIFT STATION.

11. REFER TO DETAIL A4/E-502 FOR FENCE GROUNDING

REQUIREMENTS.

12. PROVIDE 120V POWER TO EXISTING FLOOD LIGHTING FOR

BRICK SIGN. PROVIDE A STANDALONE PHOTOSENSOR JUST

NORTH OF THE SIGN FOR LIGHTING CONTROL OF

FLOODLIGHTS.

13. PROVIDE 120V/1-PHASE POWER TO WRONG WAY DETECTION

NODE BOX. COORDINATE LOCATION AND EXACT

REQUIREMENTS WITH DETECTION SENSOR VENDOR.

SCALE: 1" = 30'-0"A1

ELECTRICAL SITE PLAN - SOUTH

SCALE: 1" =

0 30 6030

30' - 0"

M A

R K

D E

S C

R

IP

T I O

N D

A T

E

A

D D

E N

D U

M

R E

V

IS

E D

D R

A W

I N G

S /2

/2

Sheets
ES101 - ELECTRICAL SITE PLAN - SOUTH

File details come from the government source that posted it. Updated .