This is a solicitation for a construction contract to build a new Entry Control Facility complex at Project No. HAAW139030. The work includes constructing a gate house, guard booth, vehicle canopies, commercial vehicle inspection bay, pavements, fencing, gates, active denial barriers, site lighting, and drainage. The project magnitude is between $1 million to $5 million. This action is set aside for Service Disabled Veteran Owned Small Businesses. The NAICS code is 236220 and the size standard is $39.5 million in average annual revenue for the past three years. The pre-bid conference and site visit are encouraged. Bids must include all items or they will be rejected. The award will be made to the responsible bidder with the most advantageous price-related factors.

View the file

Other files for this federal contract opportunity

Show all 28

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HAAW 139030, Construct Entry Control Facility B-3 Submittal

PROJECT TABLE OF CONTENTS

DI VI SI ON 01 - GENERAL REQUI REMENTS

01 11 00 SUMMARY OF WORK

01 14 00 WORK RESTRICTIONS

01 20 00.00 20 PRICE AND PAYMENT PROCEDURES

01 30 00 ADMINISTRATIVE REQUIREMENTS

01 32 01.00 10 PROJECT SCHEDULE

01 33 00 SUBMITTAL PROCEDURES

01 35 26 GOVERNMENTAL SAFETY REQUIREMENTS

01 42 00 SOURCES FOR REFERENCE PUBLICATIONS

01 45 00.00 10 QUALITY CONTROL

01 45 35 SPECIAL INSPECTIONS

01 50 00 TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS

01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS

01 74 19 CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT

01 75 00.00 40 STARTING AND ADJUSTING

01 78 00 CLOSEOUT SUBMITTALS

01 78 23 OPERATION AND MAINTENANCE DATA

01 78 24.00 10 OPERATIONS AND MAINTENANCE FACILITY DATA REQUIREMENTS

01 91 00.15 TOTAL BUILDING COMMISSIONING

DI VI SI ON 02 - EXI STI NG CONDI TI ONS

02 41 00 DEMOLITION

DI VI SI ON 03 - CONCRETE

03 30 00 CAST-IN-PLACE CONCRETE

DI VI SI ON 05 - METALS

05 12 00 STRUCTURAL STEEL

05 30 00 STEEL DECKS

05 40 00 COLD-FORMED METAL FRAMING

05 50 13 MISCELLANEOUS METAL FABRICATIONS

DI VI SI ON 06 - WOOD, PLASTI CS, AND COMPOSI TES

06 10 00 ROUGH CARPENTRY

06 41 16.00 10 PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS

06 61 16 SOLID SURFACING FABRICATIONS

DI VI SI ON 07 - THERMAL AND MOI STURE PROTECTI ON

07 42 13 METAL WALL PANELS

07 54 19 POLYVINYL-CHLORIDE ROOFING

07 60 00 FLASHING AND SHEET METAL

07 84 00 FIRESTOPPING

07 92 00 JOINT SEALANTS

DI VI SI ON 08 - OPENI NGS

08 11 13 STEEL DOORS AND FRAMES

08 14 00 WOOD DOORS

08 34 01 FORCED ENTRY RESISTANT COMPONENTS

08 34 02 BULLET-RESISTANT COMPONENTS

08 34 63 DETENTION HOLLOW METAL FRAMES, DOORS, AND DOOR FRAMES

PROJECT TABLE OF CONTENTS Page 1

08 41 13 ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

08 44 00 CURTAIN WALL AND GLAZED ASSEMBLIES

08 56 53 BLAST RESISTANT TEMPERED GLASS WINDOWS

08 71 00 DOOR HARDWARE

08 81 00 GLAZING

DI VI SI ON 09 - FI NI SHES

09 06 00 SCHEDULES FOR FINISHES

09 22 00 SUPPORTS FOR PLASTER AND GYPSUM BOARD

09 29 00 GYPSUM BOARD

09 30 10 CERAMIC, QUARRY, AND GLASS TILING

09 51 00 ACOUSTICAL CEILINGS

09 65 00 RESILIENT FLOORING

09 67 23.13 STANDARD RESINOUS FLOORING

09 90 00 PAINTS AND COATINGS

DI VI SI ON 10 - SPECI ALTI ES

10 14 00.20 INTERIOR SIGNAGE

10 14 53 TRAFFIC SIGNAGE

10 28 13 TOILET ACCESSORIES

10 44 16 FIRE EXTINGUISHERS

DI VI SI ON 12 - FURNI SHI NGS

12 32 00 MANUFACTURED WOOD CASEWORK

12 36 00 COUNTERTOPS

12 93 00 SITE FURNISHINGS

DI VI SI ON 22 - PLUMBI NG

22 00 00 PLUMBING, GENERAL PURPOSE

DI VI SI ON 23 - HEATI NG, VENTI LATI NG, AND AI R CONDI TI ONI NG ( HVAC)

23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC

23 07 00 THERMAL INSULATION FOR MECHANICAL SYSTEMS

23 09 13 INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

23 11 20 FACILITY GAS PIPING

23 23 00 REFRIGERANT PIPING

23 30 00 HVAC AIR DISTRIBUTION

23 80 20.00 10 GAS-FIRED HEATING EQUIPMENT

23 81 00 DECENTRALIZED UNITARY HVAC EQUIPMENT

23 82 01.00 10 WARM AIR HEATING SYSTEMS

DI VI SI ON 25 - I NTEGRATED AUTOMATI ON

25 05 11 CYBERSECURITY FOR FACILITY-RELATED CONTROL SYSTEMS

DI VI SI ON 26 - ELECTRI CAL

26 12 19.10 THREE-PHASE, LIQUID-FILLED PAD-MOUNTED TRANSFORMERS

26 20 00 INTERIOR DISTRIBUTION SYSTEM

26 33 53 STATIC UNINTERRUPTIBLE POWER SUPPLY (UPS)

26 51 00 INTERIOR LIGHTING

26 56 00 EXTERIOR LIGHTING

DI VI SI ON 27 - COMMUNI CATI ONS

PROJECT TABLE OF CONTENTS Page 2

27 10 00 BUILDING TELECOMMUNICATIONS CABLING SYSTEM

DI VI SI ON 28 - ELECTRONI C SAFETY AND SECURI TY

28 08 10 ELECTRONIC SECURITY SYSTEM ACCEPTANCE TESTING

28 10 05 ELECTRONIC SECURITY SYSTEMS (ESS)

DI VI SI ON 31 - EARTHWORK

31 00 00 EARTHWORK

DI VI SI ON 32 - EXTERI OR I MPROVEMENTS

32 05 33 LANDSCAPE ESTABLISHMENT

32 11 23 AGGREGATE BASE COURSES

32 12 13 BITUMINOUS TACK AND PRIME COATS

32 12 16.16 ROAD-MIX ASPHALT PAVING

32 16 19 CONCRETE CURBS, GUTTERS AND SIDEWALKS

32 17 23 PAVEMENT MARKINGS

32 31 13.53 HIGH-SECURITY FENCES (CHAIN LINK AND ORNAMENTAL) AND GATES

32 92 19 SEEDING

DI VI SI ON 33 - UTI LI TI ES

33 11 00 WATER UTILITY DISTRIBUTION PIPING

33 11 23 NATURAL GAS PIPING

33 30 00 SANITARY SEWERAGE

33 31 23.00 10 SANITARY SEWER FORCE MAIN PIPING

33 32 16 PACKAGED UTILITY WASTEWATER PUMPING STATIONS

33 40 00 STORM DRAINAGE UTILITIES

33 71 02 UNDERGROUND ELECTRICAL DISTRIBUTION

33 82 00 TELECOMMUNICATIONS OUTSIDE PLANT (OSP)

DI VI SI ON 34 - TRANSPORTATI ON

34 71 13.16 VEHICLE CRASH BARRIERS

34 71 13.19 CRASH RATED ACTIVE VEHICLE BARRIERS AND CONTROLS

-- End of Project Table of Contents --

PROJECT TABLE OF CONTENTS Page 3

THIS PAGE INTENTIONALLY LEFT BLANK

PROJECT TABLE OF CONTENTS Page 4

SECTION 08 71 00

DOOR HARDWARE

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM E283 (2019) Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen

ASTM F883 (2013) Padlocks

BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)

ANSI/BHMA A156.1 (2016) Butts and Hinges

ANSI/BHMA A156.2 (2017) Bored and Preassembled Locks and Latches

ANSI/BHMA A156.3 (2014) Exit Devices

ANSI/BHMA A156.4 (2013) Door Controls - Closers

ANSI/BHMA A156.5 (2014) Cylinder and Input Devices for Locks

ANSI/BHMA A156.6 (2015) Architectural Door Trim

ANSI/BHMA A156.7 (2016) Template Hinge Dimensions

ANSI/BHMA A156.8 (2015) Door Controls - Overhead Stops and Holders

ANSI/BHMA A156.10 (2017) Power Operated Pedestrian Doors

ANSI/BHMA A156.13 (2017) Mortise Locks & Latches Series 1000

ANSI/BHMA A156.14 (2013) Sliding and Folding Door Hardware

ANSI/BHMA A156.15 (2015) Release Devices Closer Holder, Electromagnetic and Electromechanical

ANSI/BHMA A156.16 (2018) Auxiliary Hardware

ANSI/BHMA A156.17 (2019) Self Closing Hinges & Pivots

ANSI/BHMA A156.18 (2016) Materials and Finishes

SECTION 08 71 00 Page 1

ANSI/BHMA A156.19 (2013) Power Assist & Low Energy Power Operated Doors

ANSI/BHMA A156.21 (2019) Thresholds

ANSI/BHMA A156.22 (2017) Door Gasketing and Edge Seal Systems

ANSI/BHMA A156.23 (2010) Electromagnetic Locks

ANSI/BHMA A156.24 (2012) Delayed Egress Locking Systems

ANSI/BHMA A156.25 (2013) Electrified Locking Devices

ANSI/BHMA A156.26 (2012) Continuous Hinges

ANSI/BHMA A156.27 (2011) Power and Manual Operated Revolving Pedestrian Doors

ANSI/BHMA A156.30 (2014) High Security Cylinders

ANSI/BHMA A156.31 (2013) Electric Strikes and Frame Mounted Actuators

ANSI/BHMA A156.36 (2010) Auxiliary Locks

NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)

NFPA 70 (2020; ERTA 20-1 2020; ERTA 20-2 2020; TIA

20-1; TIA 20-2; TIA 20-3; TIA 20-4)

National Electrical Code

NFPA 72 (2019; TIA 19-1; ERTA 1 2019) National Fire Alarm and Signaling Code

NFPA 80 (2019) Standard for Fire Doors and Other Opening Protectives

NFPA 101 (2018; ERTA 18-1; ERTA 18-2; ERTA 18-3;

ERTA 18-4; TIA 18-1; TIA 18-2; TIA 18-3;

TIA 18-4) Life Safety Code

NFPA 252 (2017) Standard Methods of Fire Tests of Door Assemblies

STEEL DOOR INSTITUTE (SDI/DOOR)

SDI/DOOR A250.8 (2017) Specifications for Standard Steel Doors and Frames

U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)

36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines

SECTION 08 71 00 Page 2

UNDERWRITERS LABORATORIES (UL)

UL Bld Mat Dir (updated continuously online) Building Materials Directory

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Manufacturer's Detail Drawings ; G

Verification of Existing Conditions ; G

Hardware Schedule ; G

Keying System ; G

SD-03 Product Data

Hardware Items ; G

SD-08 Manufacturer's Instructions

Installation

SD-10 Operation and Maintenance Data

Hardware Schedule Items, Data Package 1; G

SD-11 Closeout Submittals

Key Bitting

1.3 SHOP DRAWINGS

Submit manufacturer's detail drawings indicating all hardware assembly components and interface with adjacent construction. Indicate power components and wiring coordination for electrified hardware. Base shop drawings on verified field measurements and include verification of existing conditions .

1.4 PRODUCT DATA

Indicate fire-ratings at applicable components. Provide documentation of ABA/ADA accessibility compliance of applicable components, as required by 36 CFR 1191 Appendix D - Technical.

1.5 HARDWARE SCHEDULE

Prepare and submit hardware schedule in the following form:

SECTION 08 71 00 Page 3

Hardware Item

Quantity Size Reference Publi-cation Type No.

Finish Mfr Name and Catalog No.

Key Control Symbols

UL

Mark (If fire-rated and listed)

BHMA

Finish Desig-nation

In addition, submit hardware schedule data package 1 in accordance with Section 01 78 23 OPERATION AND MAINTENANCE DATA.

1.6 KEY BITTING CHART REQUIREMENTS

1.6.1 Requirements

Submit key bitting charts to the Contracting Officer prior to completion of the work. Include:

a. Complete listing of all keys (e.g. AA1 and AA2).

b. Complete listing of all key cuts (AA1-123456, AA2-123458).

c. Tabulation showing which key fits which door.

d. Copy of floor plan showing doors and door numbers.

e. Listing of 20 percent more key cuts than are presently required in each master system.

1.7 QUALITY ASSURANCE

1.7.1 Hardware Manufacturers and Modifications

Provide, as far as feasible, locks, hinges, and closers of one lock, hinge, or closer manufacturer's make. Modify hardware as necessary to provide features indicated or specified.

1.7.2 Key Shop Drawings Coordination Meeting

Prior to the submission of the key shop drawing, the Contracting Officer, Contractor, Door Hardware Subcontractor, using Activity and Base Locksmith must meet to discuss and coordinate key requirements for the facility.

1.8 DELIVERY, STORAGE, AND HANDLING

Deliver hardware in original individual containers, complete with necessary appurtenances including fasteners and instructions. Mark each individual container with item number as shown on hardware schedule.

Deliver permanent keys to the Contracting Officer, either directly or by certified mail. Deliver construction master keys with the locks.

PART 2 PRODUCTS

2.1 TEMPLATE HARDWARE

Hardware applied to metal doors must be manufactured using a template.

Provide templates to door and frame manufacturers in accordance with

SECTION 08 71 00 Page 4

ANSI/BHMA A156.7 for template hinges. Coordinate hardware items to prevent interference with other hardware.

2.2 HARDWARE FOR FIRE DOORS AND EXIT DOORS

Provide all hardware necessary to meet the requirements of NFPA 72 for door alarms, NFPA 80 for fire doors, NFPA 101 for exit doors, NFPA 252 for fire tests of door assemblies, ABA/ADA accessibility requirements, and all other requirements indicated, even if such hardware is not specifically mentioned in paragraph HARDWARE SCHEDULE. Provide Underwriters Laboratories, Inc. labels for such hardware in accordance with UL Bld Mat Dir or equivalent labels in accordance with another testing laboratory approved in writing by the Contracting Officer.

2.3 HARDWARE ITEMS

Clearly and permanently mark with the manufacturer's name or trademark, hinges, pivots, locks, latches, exit devices, bolts and closers where the identifying mark is visible after the item is installed. For closers with covers, the name or trademark may be beneath the cover. Coordinate electrified door hardware components with corresponding components specified in Division 28 ELECTRONIC SECURITY SYSTEMS (ESS).

2.3.1 Hinges

Provide in accordance with ANSI/BHMA A156.1 . Provide hinges that are 4-1/2 by 4-1/2 inch unless otherwise indicated. Construct loose pin hinges for interior doors and reverse-bevel exterior doors so that pins are non-removable when door is closed. Other anti-friction bearing hinges may be provided in lieu of ball bearing hinges.

2.3.1.1 Protection Devices

Provide full height hand and finger protection device at the hinge-side area opening of doors and gates. Provide hinge-side protection devices on both sides of doors and gates, covering hinges and space between door and frame when doors are in the open position. The installed device must push hand and fingers out of the opening and away from a crushing hazard.

2.3.2 Continuous Hinges

Where continuous hinges are required, provide in accordance with

ANSI/BHMA A156.26 .

2.3.3 Pivots

Provide in accordance with ANSI/BHMA A156.17 .

2.3.4 Spring Hinges

Provide in accordance with ANSI/BHMA A156.17 .

2.3.5 Locks and Latches

a. At exterior locations provide locksets of full stainless steel type 302 or 304 construction including fronts, strike, escutcheons, knobs, bolts and all interior working parts. Marine Grade I, fully non-ferrous.

SECTION 08 71 00 Page 5

b. In non-air-conditioned interior environments or humid interior environments, provide interior locksets on the same Marine Grade I, fully non-ferrous as exterior locksets.

2.3.5.1 Mortise Locks and Latches

Provide in accordance with ANSI/BHMA A156.13 , Series 1000, Operational Grade 1, Security Grade 2. Provide factory installed lead lining in locks for lead shielded doors. Provide knobs and roses of mortise locks with screwless shanks and no exposed screws.

2.3.5.2 Bored Locks and Latches

Provide in accordance with ANSI/BHMA A156.2 , Series 4000, Grade 1.

Provide factory installed lead lining in locks for lead -shielded doors.

2.3.5.3 Residential Bored Locks and Latches

Provide in accordance with ANSI/BHMA A156.2 , Series 4000, Grade 2.

Install locks for exterior doors with threaded roses or concealed machine screws.

2.3.5.4 Hospital Latches

Push-pull latch set similar and equal to Glynn-Johnson HL6, 1/2 inch throw, 2-3/4 inch backset, to fit 161 cutout. Cover approximately 2-1/2 by 5-1/2 inch , handle approximately 1-1/2 by 4-1/2 inch , projection approximately 2-1/2 inch , covers and handles of stainless steel, BHMA 630 finish, engraved "PUSH" and "PULL" on handles, push handle pointing up, pull handle pointing down.

2.3.5.5 Auxiliary Locks

Provide in accordance with ANSI/BHMA A156.36 , Grade 1.

2.3.5.6 Combination Locks

Heavy-duty, mechanical combination lockset with five push buttons, standard sized knobs, 3/4 inch deadlocking latch, 2-3/4 inch backset.

Locks to operate by pressing two or more of the buttons in unison or individually in the proper sequence. Inside knob operates the latch.

Provide a keyed cylinder on the interior to permit setting the combination.

2.3.6 Exit Devices

Provide in accordance with ANSI/BHMA A156.3 , Grade 1. Provide adjustable strikes for rim type and vertical rod devices. Provide open back strikes for pairs of doors with mortise and vertical rod devices. Provide Provide escutcheons not less than 7 by 2-1/4 inch .

Use stainless steel or bronze base metal with plated finishes. Also include stainless steel fasteners and screws.

2.3.7 Cylinders and Cores

Provide cylinders and cores with seven pin tumblers. Provide cylinders from the products of one manufacturer, and provide cores from the products of one manufacturer. Rim cylinders, mortise cylinders, and knobs of bored locksets have interchangeable cores which are removable by special control

SECTION 08 71 00 Page 6 keys. Stamp each interchangeable core with a key control symbol in a concealed place on the core.

Provide cylinders for new locks, including locks provided under other sections of this specification. Provide fully compatible cylinders of Grade 1 products from products of one manufacturer with interchangeable cores that are removable by a special control key. Factory set the cores with seven pin tumblers using the A4 system and F keyway. Submit a core code sheet with the cores. Provide master keyed cores in one system for this project. Provide construction interchangeable cores.

2.3.7.1 High Security Cylinders

Provide in accordance with ANSI/BHMA A156.30 , security level A for all high security cylinder components.

2.3.8 Push Button Mechanisms

Provide in accordance with ANSI/BHMA A156.5 , Grade 1.

2.3.9 Electrified Hardware

Comply with the requirements of NFPA 70 for wiring of electrified hardware.

2.3.9.1 Electric Strikes and Frame Mounted Actuators

Provide in accordance with ANSI/BHMA A156.31 , Grade 1. Provide electric strikes and actuators as required to meet operational requirements.

Provide electric strikes that remain secure during power failure. Provide battery backup for continued operation during power failure. Provide strikes and actuators with a minimum opening force of 2300 pounds .

Provide facility interface devices that use direct current (dc) power to energize the solenoids. Provide electric strikes and actuators that incorporate end-of-line resistors to facilitate line supervision by the system. If not incorporated into the electric strike or local controller, provide metal oxide resistors (MOVs) to protect the controller from reverse current surges.

2.3.9.1.1 Solenoid

Provide actuating solenoid for strikes and actuators that are rated for continuous duty, cannot dissipate more than 12 Watts and must operate on 12 or 24 Volts dc. Inrush current cannot exceed 1 ampere and the holding current cannot be greater than 500 milliamperes. Actuating solenoid must move from fully secure to fully open positions in less than 500 milliseconds.

2.3.9.1.2 Signal Switches

Provide strikes and actuators with signal switches to indicate to the system when the bolt is not engaged or the strike mechanism is unlocked.

Signal switches must report a forced entry to the system.

2.3.9.1.3 Tamper Resistance

Provide strike guards that prevent tampering with the latch bolt of the locking hardware or the latch bolt keeper of the electric strike. Strike guards to bolt through the door using tamper resistant screws. Provide

SECTION 08 71 00 Page 7 strike guards made of 1/8 inch thick brass and that are 11-1/14 inch high by 1-5/8 inch wide , with a minimum 5/32 inch wide offset.

2.3.9.1.4 Coordination

Provide electric strikes and actuators of a size, weight and profile compatible with each specified door frame. Field verify installation clearances prior to procurement.

2.3.9.1.5 Mounting Method

Provide electric strikes and actuators suitable for use with single and double doors, with mortise or rim type hardware specified, and for right or left hand mounting as specified. In double door installations, locate the lock in the active leaf and monitor the fixed leaf.

2.3.9.2 Electrified Mortise Locks

Provide in accordance with ANSI/BHMA A156.25 , Grade 1. Provide electrified mortise locks that remain secure during power failure.

Provide facility interface devices that use dc power to energize solenoids. Provide solenoids, resisters, and signal switches in accordance with paragraph ELECTRIC STRIKES AND FRAME MOUNTED ACTUATORS.

2.3.9.2.1 Power Transfer Hinges

Provide power transfer hinges with each electrified lock that route power and monitoring signals from the lockset to the door frame. Coordinate power transfer hinges with door frames.

2.3.9.3 Card Readers and Keypad Access Control Hardware

Provide in accordance with ANSI/BHMA A156.5 and ANSI/BHMA A156.25 , Grade 1 components. Provide devices that are tamper alarmed, tamper and vandal resistant, solid state, and do not contain electronics which could compromise the access control subsystem should the subsystem be attacked.

Provide surface, semi-flush, pedestal, or weatherproof mountable devices as specified for each individual location. Provide swipe through type card readers capable of reading Smart Card type access control cards. Provide keypads that contain an integral 12-digit tactile keyboard with digits.

Provide keypads that are integrated into the card reader. Coordinate access control hardware with corresponding devices and systems specified in Division 28 ELECTRONIC SECURITY SYSTEMS (ESS).

2.3.9.4 Power Operated Pedestrian Door Hardware

Provide in accordance with ANSI/BHMA A156.10 , Grade 1.

2.3.9.5 Release Devices

In accordance with ANSI/BHMA A156.15 , Grade 1.

2.3.9.5.1 Closer Holders

Provide header mounted closer holder devices connected by separate releasing to fire detecting devices.

SECTION 08 71 00 Page 8

2.3.9.6 Power Assist and Low Energy Power Operated Doors

Provide in accordance with ANSI/BHMA A156.19 , Grade 1.

2.3.9.7 Electromagnetic Locks

Provide in accordance with ANSI/BHMA A156.23 , Grade 1. Provide electromagnetic locks that do not contain any moving parts and depend solely upon electromagnetism to secure a portal by generating at least 1200 pounds of holding force. The lock must interface with the local processors without external, internal or functional alteration of the local processor. The electromagnetic lock must incorporate an end of line resistor to facilitate line supervision by the system. Provide metal-oxide resistors (MOVs) to protect controllers from reverse current surges, if not incorporated into the electromagnetic lock or local controller.

2.3.9.7.1 Armature

Provide electromagnetic locks with internal circuitry to eliminate residual magnetism and inductive kickback. Provide atuating armature that operates on 12 or 24 Volts dc and cannot dissipate more than 12 Watts.

Holding current must be less than 500 milliamperes. Actuating armature must take less than 300 milliseconds to change the status of the lock from fully secure to fully open or fully open to fully secure.

2.3.9.7.2 Tamper Resistance

Provide lock mechanism encased in hardened guard barriers to deter forced entry.

2.3.9.7.3 Mounting Method

Provide electromagnetic lock suitable for use with single and double door with mortise or rim type hardware and compatible with right or left hand mounting.

2.3.9.8 Delayed Egress Locking System

Provide in accordance with ANSI/BHMA A156.24 , Grade 1.

2.3.9.9 Power and Manual Operated Revolving Pedestrian Doors

Provide in accordance with ANSI/BHMA A156.27 , Grade 1.

2.3.10 Keying System

Provide an extension of the existing keying system. Existing locks were manufactured by best and have interchangeable cores.

Provide cylinders of Grade 1 products from one manufacturer. Notify the Contracting Officer 90 days prior to the required delivery of the cylinders. Provide temporary cores and keys for the Contractor's use during construction, and for testing of locksets.

2.3.11 Lock Trim

Provide cast, forged, or heavy wrought construction and commercial plain design for lock trim.

SECTION 08 71 00 Page 9

2.3.11.1 Knobs and Roses

Provide in accordance with ANSI/BHMA A156.2 and ANSI/BHMA A156.13 for knobs, roses, and escutcheons. For unreinforced knobs, roses, and escutcheons, provide a 0.050 inch thickness. For reinforced knobs, roses, and escutcheons, provide an outer shell thickness of 0.035 inch and a combined total thickness of 0.070 inch , except at knob shanks. Provide knob shanks 0.060 inch thick.

2.3.11.2 Lever Handles

Provide lever handles where indicated in the Hardware Schedule. Provide in accordance with ANSI/BHMA A156.3 for mortise locks of lever handles for exit devices. Provide lever handle locks with a breakaway feature (such as a weakened spindle or a shear key) to prevent irreparable damage to the lock when force in excess of that specified in ANSI/BHMA A156.13 is applied to the lever handle. Provide lever handles return to within 1/2 inch of the door face.

2.3.11.3 Texture

Provide knurled or abrasive coated knobs or lever handles for doors which are accessible to blind persons and which lead to dangerous areas.

2.3.12 Keys

Provide one file key, one duplicate key, and one working key for each key change and for each master keying system. Furnish one additional working key for each lock of each keyed-alike group. Provide 2 control keys for removable cores. Provide a quantity of key blanks equal to 20 percent of the total number of file keys. Stamp each key with appropriate key control symbol and "U.S. property - do not duplicate." Do not place room number on keys.

Provide seven change keys for each interchangeable core, provide two control keys, six maters keys, and six construction master keys. Provide a quantity of key blanks equal to 20 percent of the total number of change keys. Stamp each key with appropriate key control symbol and "U.S.

property - do not duplicate." Do not place room numbers on keys.

2.3.13 Door Bolts

Provide in accordance with ANSI/BHMA A156.16 . Provide dustproof strikes for bottom bolts, except at doors having metal thresholds. Provide automatic latching flush bolts in accordance with ANSI/BHMA A156.3 , Type 25.

2.3.14 Closers

Provide in accordance with ANSI/BHMA A156.4 , Series C02000, Grade 1, with PT 4C. Provide with brackets, arms, mounting devices, fasteners, full size covers, except at storefront mounting, and other features necessary for the particular application. Size closers in accordance with manufacturer's printed recommendations, or provide multi-size closers, Sizes 1 through 6, and list sizes in the Hardware Schedule. Provide manufacturer's 10 year warranty.

Use stainless steel inside bracketed or door mounted closers on exterior

SECTION 08 71 00 Page 10 doors. Non-ferrous closers, such as aluminum or cast bronze, are permissible where door utilization is minimal. On interior doors use closers of 302 or 304 stainless steel or non-ferrous materials. On surface-mounted closers use or apply rust inhibiting finish on all ferrous parts. Also apply this finish on concealed closers.

2.3.14.1 Identification Marking

Engrave each closer with manufacturer's name or trademark, date of manufacture, and manufacturer's size designation in locations that will be visible after installation.

2.3.15 Overhead Holders

Provide in accordance with ANSI/BHMA A156.8 .

2.3.16 Door Protection Plates

Provide in accordance with ANSI/BHMA A156.6 .

2.3.16.1 Sizes of Kick Plates

2 inch less than door width for single doors; 1 inch less than door width for pairs of doors. Provide 8 inch kick plates for flush doors. Provide a minimum 36 .

2.3.17 Door Stops and Silencers

Provide in accordance with ANSI/BHMA A156.16 . Silencers Type L03011.

Provide three silencers for each single door, two for each pair.

2.3.18 Padlocks

Provide in accordance with ASTM F883.

2.3.19 Thresholds

Provide in accordance with ANSI/BHMA A156.21 . Use J35100, with vinyl or silicone rubber insert in face of stop, for exterior doors opening out, unless specified otherwise.

2.3.20 Weatherstripping Gasketing

Provide in accordance with ANSI/BHMA A156.22 . Provide the type and function designation where specified in paragraph HARDWARE SCHEDULE.

Provide a set to include head and jamb seals, sweep strips,. Air leakage of weatherstripped doors not to exceed 0.5 cubic feet per minute of air per square foot of door area when tested in accordance with ASTM E283.

Provide weatherstripping with one of the following:

2.3.20.1 Extruded Aluminum Retainers

Extruded aluminum retainers not less than 0.050 inch wall thickness with vinyl, neoprene, silicone rubber, or polyurethane inserts. Provide clear (natural) anodized aluminum.

2.3.20.2 Interlocking Type

Zinc or bronze not less than 0.018 inch thick.

SECTION 08 71 00 Page 11

2.3.20.3 Spring Tension Type

Spring bronze or stainless steel not less than 0.008 inch thick.

2.3.21 Lightproofing Gasketing

Provide in accordance with ANSI/BHMA A156.22 . Provide adjustable doorstops at heads,jambs and automatic door bottoms in accordance with the hardware set, of extruded aluminum, clear (natural) anodized, surface applied, with vinyl fin seals between plunger and housing. Provide doorstops with solid neoprene tube, silicone rubber, or closed cell sponge gasket. Provide door bottoms with adjustable operating rod and silicone rubber or closed cell sponge neoprene gasket. Provide doorstops that are mitered at corners. Provide type and function designation where specified in paragraph HARDWARE SETS.

2.3.22 Rain Drips

Provide in accordance with ANSI/BHMA A156.22 . Provide extruded aluminum rain drips, not less than 0.08 inch thick, clear anodized finish. Provide the manufacturer's full range of color choices to the Contracting Officer for color selection. Set drips in sealant and fasten with stainless steel screws.

2.3.22.1 Door Rain Drips

Approximately 1-1/2 inch high by 5/8 inch projection. Align bottom with bottom edge of door.

2.3.22.2 Overhead Rain Drips

Approximately 1-1/2 inch high by 2-1/2 inch projection. Align bottom with door frame rabbet.

2.3.23 Auxiliary Hardware (Other than locks)

Provide in accordance with ANSI/BHMA A156.16 , Grade 1.

2.3.24 Sliding and Folding Door Hardware

Provide in accordance with ANSI/BHMA A156.14 , Grade 1. Finishes to match other hardware specified herein.

2.3.25 Special Tools

Provide special tools, such as spanner and socket wrenches and dogging keys, as required to service and adjust hardware items.

2.4 FASTENERS

Provide fasteners of type, quality, size, and quantity appropriate to the specific application. Fastener finish to match hardware. Provide stainless steel or nonferrous metal fasteners in locations exposed to weather. Verify metals in contact with one another are compatible and will avoid galvanic corrosion when exposed to weather.

SECTION 08 71 00 Page 12

2.5 FINISHES

Provide in accordance with ANSI/BHMA A156.18 . Provide hardware in BHMA 630 finish (satin stainless steel), unless specified otherwise. Provide items not manufactured in stainless steel in BHMA 626 finish (satin chromium plated) over brass or bronze, except aluminum paint finish for surface door closers, and except BHMA 652 finish (satin chromium plated) for steel hinges.

PART 3 EXECUTION

3.1 INSTALLATION

Provide hardware in accordance with manufacturers' printed installation instructions. Fasten hardware to wood surfaces with full-threaded wood screws or sheet metal screws. Provide machine screws set in expansion shields for fastening hardware to solid concrete and masonry surfaces.

Provide toggle bolts where required for fastening to hollow core construction. Provide through bolts where necessary for satisfactory installation.

3.1.1 Weatherstripping Installation

Provide full contact, weathertight seals that allow operation of doors without binding the weatherstripping.

3.1.1.1 Stop Applied Weatherstripping

Fasten in place with color matched sheet metal screws not more than 9 inch on center after doors and frames have been finish painted.

3.1.1.2 Interlocking Type Weatherstripping

Provide interlocking, self adjusting type on heads and jambs and flexible hook type at sills. Nail weatherstripping to door 1 inch on center and to heads and jambs at 4 inch on center.

3.1.1.3 Spring Tension Type Weatherstripping

Provide spring tension type on heads and jambs. Provide bronze nails with bronze. Provide stainless steel nails with stainless steel. Space nails not more than 1-1/2 inch on center.

3.1.2 Lightproofing Installation

Provide as specified for stop applied weatherstripping.

3.1.3 Threshold Installation

Extend thresholds the full width of the opening and notch end for jamb stops. Set thresholds in a full bed of sealant and anchor to floor with cadmium-plated, countersunk, steel screws. For aluminum thresholds placed on top of concrete surfaces, coat the underside surfaces that are in contact with the concrete with fluid applied waterproofing as a separation measure prior to placement.

3.2 FIRE DOORS AND EXIT DOORS

Provide hardware in accordance with NFPA 72 for door alarms, NFPA 80 for

SECTION 08 71 00 Page 13 fire doors, NFPA 101 for exit doors, and NFPA 252 for fire tests of door assemblies.

3.3 HARDWARE LOCATIONS

Provide in accordance with SDI/DOOR A250.8 , unless indicated or specified otherwise.

a. Kick and Armor Plates: Push side of single-acting doors. Both sides of double-acting doors.

b. Mop Plates: Bottom flush with bottom of door.

3.4 FIELD QUALITY CONTROL

After installation, protect hardware from paint, stains, blemishes, and other damage until acceptance of work. Submit notice of testing 15 days before scheduled, so that testing can be witnessed by the Contracting Officer. Adjust hinges, locks, latches, bolts, holders, closers, and other items to operate properly. Demonstrate that permanent keys operate respective locks, and give keys to the Contracting Officer. Correct, repair, and finish, errors in cutting and fitting and damage to adjoining work.

3.5 HARDWARE SETS

SECTION 08 71 00 Page 14

Set: 1.0

Doors: 100A, 100B

1 Continuous Hinge (A31031G) CFM (height)SLF-HD1 PE

1 Exit Device (Type 1, 03) 16 72 8804 US32D SA

2 Interchangeable Core (E09241)

33600006N 26 MC

1 Door Pull (J402) BF158 US32D RO

1 Surface Closer

(C02021-PT4G)

CPS8501 M 689 NO

1 Sweep (R3D534) 345AV PE

Notes:

*Waiver may be required to comply with Buy American Act.

• Perimeter/meeting stile seals by frame/door supplier.

Cores to be best (or compatible)

Set: 2.0

Doors: 105

1 Continuous Hinge (A31031G) CFM (height) HD1 PE

1 Deadlock (E8281 / E8291)* MS1850S 628 AD

1 Interchangeable Core (E09241)

33600006N 26 MC

1 Surface Closer

(C02021-PT4G)

CPS8501 M 689 NO

1 Gasketing (R0Y264) 379CS PE

1 Rain Guard (R0Y976) 346C PE

2 Sweep (R3D534) 345AV PE

1 Door Pull (J402) BF158 US32D

SECTION 08 71 00 Page 15

Notes:

Door is for Bid Option 4

*Waiver may be required to comply with Buy American Act.

Cores to be best (or compatible)

Set: 3.0

Doors: 104

3 Continuous Hinge (A31031G) CFM (height) HD1 PE

1 Storeroom Lock (F07) 72 8204 LNL US26D SA

1 Interchangeable Core (E09241)

33600006N 26 MC

1 Surface Closer

(C02021-PT4G)

CPS8501 M 689 NO

1 Kick Plate (J102) K1050 10" CSK US32D RO

1 Threshold (J36100) 2009APK PE

1 Gasketing (R3E164) 303AS (HEAD/JAMBS) PE

1 Sweep (R3D534) 345AV PE

Notes:

*Waiver may be required to comply with Buy American Act.

Cores to be best (or compatible)

Set: 4.0

Doors: 103

3 Hinge (A8112) TA2714 x USA US26D MK

1 Privacy Lock (F22) V21 8265 LNL US26D SA

SECTION 08 71 00 Page 16

1 Surface Closer (C02011 / C02021)

R / PR8501 M 689 NO

1 Kick Plate (J102) K1050 10" CSK US32D RO

1 Mop Plate (J103) K1050 6" CSK US32D RO

1 Door Stop (L02251 / L02121)*

403/470 US26D RO

Notes:

*Waiver may be required to comply with Buy American Act.

Sound seals, door bottoms and thresholds by the door manufacturer to meet STC 45 requirement.

• Mop plate at inswinging doors only.

Cores to be best (or compatible)

-- End of Section --

SECTION 08 71 00 Page 17

THIS PAGE INTENTIONALLY LEFT BLANK

SECTION 08 71 00 Page 18

PROJECT TABLE OF CONTENTS
DIVISION 08 - OPENINGS
08 71 00 - DOOR HARDWARE
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 SHOP DRAWINGS
1.4 PRODUCT DATA
1.5 HARDWARE SCHEDULE
1.6 KEY BITTING CHART REQUIREMENTS
1.6.1 Requirements
1.7 QUALITY ASSURANCE
1.7.1 Hardware Manufacturers and Modifications
1.7.2 Key Shop Drawings Coordination Meeting

1.8 DELIVERY, STORAGE, AND HANDLING

PART 2 PRODUCTS
2.1 TEMPLATE HARDWARE
2.2 HARDWARE FOR FIRE DOORS AND EXIT DOORS
2.3 HARDWARE ITEMS
2.3.1 Hinges
2.3.1.1 Protection Devices
2.3.2 Continuous Hinges
2.3.3 Pivots
2.3.4 Spring Hinges
2.3.5 Locks and Latches
2.3.5.1 Mortise Locks and Latches
2.3.5.2 Bored Locks and Latches
2.3.5.3 Residential Bored Locks and Latches
2.3.5.4 Hospital Latches
2.3.5.5 Auxiliary Locks
2.3.5.6 Combination Locks
2.3.6 Exit Devices
2.3.7 Cylinders and Cores
2.3.7.1 High Security Cylinders
2.3.8 Push Button Mechanisms
2.3.9 Electrified Hardware
2.3.9.1 Electric Strikes and Frame Mounted Actuators
2.3.9.1.1 Solenoid
2.3.9.1.2 Signal Switches
2.3.9.1.3 Tamper Resistance
2.3.9.1.4 Coordination
2.3.9.1.5 Mounting Method
2.3.9.2 Electrified Mortise Locks
2.3.9.2.1 Power Transfer Hinges
2.3.9.3 Card Readers and Keypad Access Control Hardware
2.3.9.4 Power Operated Pedestrian Door Hardware
2.3.9.5 Release Devices
2.3.9.5.1 Closer Holders
2.3.9.6 Power Assist and Low Energy Power Operated Doors
2.3.9.7 Electromagnetic Locks
2.3.9.7.1 Armature
2.3.9.7.2 Tamper Resistance
2.3.9.7.3 Mounting Method
2.3.9.8 Delayed Egress Locking System
2.3.9.9 Power and Manual Operated Revolving Pedestrian Doors
2.3.10 Keying System
2.3.11 Lock Trim
2.3.11.1 Knobs and Roses
2.3.11.2 Lever Handles
2.3.11.3 Texture
2.3.12 Keys
2.3.13 Door Bolts
2.3.14 Closers
2.3.14.1 Identification Marking
2.3.15 Overhead Holders
2.3.16 Door Protection Plates
2.3.16.1 Sizes of Kick Plates
2.3.17 Door Stops and Silencers
2.3.18 Padlocks
2.3.19 Thresholds
2.3.20 Weatherstripping Gasketing
2.3.20.1 Extruded Aluminum Retainers
2.3.20.2 Interlocking Type
2.3.20.3 Spring Tension Type
2.3.21 Lightproofing Gasketing
2.3.22 Rain Drips
2.3.22.1 Door Rain Drips
2.3.22.2 Overhead Rain Drips
2.3.23 Auxiliary Hardware Other than locks
2.3.24 Sliding and Folding Door Hardware
2.3.25 Special Tools
2.4 FASTENERS
2.5 FINISHES
PART 3 EXECUTION
3.1 INSTALLATION
3.1.1 Weatherstripping Installation
3.1.1.1 Stop Applied Weatherstripping
3.1.1.2 Interlocking Type Weatherstripping
3.1.1.3 Spring Tension Type Weatherstripping
3.1.2 Lightproofing Installation
3.1.3 Threshold Installation
3.2 FIRE DOORS AND EXIT DOORS
3.3 HARDWARE LOCATIONS
3.4 FIELD QUALITY CONTROL
3.5 HARDWARE SETS