This is Addendum 03 to the drawings and specifications for the New Security Forces Building project for the North Carolina Air National Guard's 124th Fighter Wing located in Charlotte, North Carolina, issued July 30, 2026.

The addendum modifies the original contract documents through revisions to Drawing C101 Site Layout Plan. Specifically, the prefabricated carport has been removed from the site design, and coded note 6 regarding the tower has been updated. The revised Drawing C101 is attached as part of this addendum. The updated drawing shows the proposed 5,713 square foot building with finished floor elevation at 711.75 feet, site utilities including storm sewer infiltration trenches and a vegetated swale, and the self-supporting 60-foot tall radio tower with six antennas (two 700/800 MHz monopoles, three 136-174 MHz monopoles, and one 165-170 MHz monopole). The project design includes concrete and asphalt pavement, sidewalks, curbs and gutters, a prefabricated pedestrian bridge with exterior stairs, accessible parking spaces, and associated site infrastructure. No revisions to the project manual specifications were made in this addendum. Contractors are required to incorporate these drawing revisions into their proposals, and the addendum becomes part of the binding contract documents.

View the file

Other files

File Type Posted
Construct Security Forces Bldg Abstract.pdf PDF
Bid Opening Sign-in Sheet.pdf PDF
Solicitation Amendment W50S8726BA0020006 SF 30.pdf PDF
Solicitation Amendment W50S8726BA0020005 SF 30.pdf PDF
Attachment 14 - Questions and Answers - Final.pdf PDF
Solicitation Amendment W50S8726BA0020003 SF 30.pdf PDF
Attachment 14 - Questions and Answers - Final.pdf PDF
Solicitation Amendment W50S8726BA0020004 SF 30.pdf PDF
Attachment 13 - NC ANG SF_Addendum02_07-10-2026.pdf PDF
Attachment 12 - NC ANG SF_Addendum01_07-01-2026.pdf PDF
Solicitation Amendment W50S8726BA0020002 SF 30.pdf PDF
PreBidSlides_W50S87-26-B-A002 Construct SFS Building.pdf PDF
Site Visit Minutes FINAL (1).pdf PDF
Sign-in sheets.pdf PDF
Solicitation Amendment W50S8726BA0020001 SF 30.pdf PDF
Attachment 11 - Submittal Register.pdf PDF
Attachment 3 - FJRP229030 B-3 Rev Proj Spec Manual vol2.pdf PDF
Attachment 5 Visitor Request Worksheet.pdf PDF
Attachment 2 - FJRP229030 B-3 Rev Proj Spec Manual vol1.pdf PDF
Attachment 8 - Brand name justification-Interior and exterior finishes.pdf PDF
Attachment 10 - Wage Determination.pdf PDF
Attachment 4 - FJRP229030 B-3 Rev Drawings.pdf PDF
Attachment 6 - Limited Competition Justification Alerton -KO signed.pdf PDF
Attachment 9 -Limited Competition Justification Monaco - KO signed.pdf PDF
Solicitation - W50S8726BA002 Final 22 May 26.pdf PDF
Attachment 1 - FJRP229030 - SOW CNS SFS Admin.pdf PDF
Attachment 7 - Limited Competition Justification Door Hardware - KO signed.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

New Security Forces Building Addendum 03 Page 1 of 1

NC ANG Security Forces Building Charolotte, NC

July 30, 2026

Addendum 03

VIA ELECTRONIC TRANSMISSION

TO THE DRAWINGS AND SPECIFICATIONS FOR:

New Security Forces Building for

North Caroline Air Nation Guard 124th fighter wing

Charlotte, NC

This Addendum supplements and amends the original Plans and Specifications and shall be taken into account in preparing proposals and shall become a part of the contract documents.

1.0 PROJECT MANUAL REVISIONS

1. None

2.0 DRAWINGS REVISIONS

1. Drawing C101 Site Layout Plan

a. Removed prefabricated carport

b. Updated coded note 6 regarding the tower

Attachments

1. Drawing C101 Site Layout Plan

END OF ADDENDUM 03

VA

N

10.0'

10.0'

6.0' 13.6'

5.0'

10.0'

22.3'

9.0' 8.0'

8.0' 8.0'

PROPOSED BUILDING

5,713 SF

FFE.: 711.75

1.

1.

55.20'

55.20'

RADIO

TOWER

BR

ID

G E

FO

O

TP

R

IN

T

STAIRS FOOTPRINT

COCO

18.0'

MH

CATV

71.2'

CLIENT

CONSULTANT

CONSULTANTS

REGISTRATION

ISSUE/REVISION

SHEET NUMBER

SHEET TITLE

PROJECT NUMBER

L as t P lo tt ed

F ile n a m e

Printed on ___% Post-Consumer Recycled Content Paper

A R

C H

E

0" x4

P ro je ct M a n a g e m e n t I ni tia ls

D es ig n e r:

C h e ck ed

A pp ro ve d

KEY PLAN

PROJECT

©2016 AECOM Corporation

/2

9/

:2

4:

P M c:

\u se rs

\c h ad .v a n so el e n

\o n e dr iv e a e co m \6

-s f n c a ng g e n er al \9 ca d

_g is

\9 ca d \c iv il\ c-sh e et s\ c1 s ite la yo ut p la n

.d w g

60637899

FJRP229030

G H

F M

C L

JR

O

AECOM

NEW SECURITY FORCES

BUILDING

NORTH CAROLINA AIR NATIONAL

GUARD-145TH AIRLIFT WING

145th AIRLIFT WING

4930 MINUTEMAN WAY

CHARLOTTE, NORTH CAROLINA 28208

-A R

C H

IT

E

C T

U R

E -A

-B

U

IL

D

IN

G S

E C

T

IO

N S

I/R DATE DESCRIPTION

277 W NATIONWIDE BLVD

COLUMBUS, OHIO 43215

614-464-4500

PAYNE BLVD

CHARLOTTE, NORTH CAROLINA 28208

http://www.aecom.com

B-3 SUBMITTAL - FINAL05/30/25

ADDENDUM 0107/01/262

SITE LAYOUT PLAN

C101

ASPHALT PAVEMENT

CONCRETE PAVEMENT

N

Know what's

R

PROPOSED SITE LEGEND

SITE LAYOUT NOTES

1. SEE ELECTRICAL PLANS FOR LOCATION AND DETAILS ON SITE LIGHTING & ELECTRICAL

FEATURES.

2. SEE ARCHITECTURAL PLANS FOR CONCRETE STOOP CONNECTION DETAILS.

3. SEE ARCHITECTURAL FOUNDATION PLAN FOR DETAILING OF BUILDING AND EXACT BUILDING

DIMENSIONS.

4. COORDINATE WITH IRRIGATION AND ELECTRICAL CONTRACTOR FOR SIZE AND PLACEMENT

OF ALL SLEEVES PRIOR TO PAVING, CONCRETE AND LANDSCAPE WORK.

5. CONCRETE GUTTER PAN SHALL TIP IN THE SAME DIRECTION AS THE ADJACENT PAVEMENT.

6. SMOOTH, GRADUAL FLOW LINE TRANSITIONS SHALL BE CONSTRUCTED BETWEEN

STANDARD GUTTER PAN AND INVERTED GUTTER PAN AND MAINTAIN DRAINAGE.

7. ALL DIMENSIONS SHOWN TO CONCRETE CURB & GUTTER ARE TO FRONT/FACE OF CURB

UNLESS NOTED OTHERWISE. BC = BACK OF CURB, FC = FACE OF CURB, EOP = EDGE OF

PAVEMENT

8. THE LAST THREE FEET OF ALL CURBS SHALL BE DUBBED DOWN UNLESS NOTED OTHERWISE.

9. ALL NCDOT REFERENCES ARE TO THE 2018 EDITION OF STANDARD SPECIFICATIONS FOR

ALL CURB/GUTTER, PAVEMENT, ETC. THE AUTHORITY HAVING JURISDICTION FOR ALL

CONSTRUCTION ON BASE IS THE CONTRACTING OFFICER OR CONTRACTING OFFICER'S

REPRESENTATIVE.

12. CONTRACTOR IS RESPONSIBLE TO COORDINATE ALL SITE UTILITY CONNECTIONS AND

INSPECTIONS WITH THE PROPER JURISDICTION AND PAY ALL ASSOCIATED FEES.

13. THE CONTRACTOR SHALL FIELD VERIFY LOCATION AND ELEVATION OF EXISTING WATER,

SANITARY SEWER, AND STORM SEWER CROSSINGS AND CONNECTION POINTS PRIOR TO

CONSTRUCTION. CONTACT ENGINEER WITH ANY DISCREPANCIES.

14. ALL PAVEMENT MARKINGS SHALL BE 4" WIDE. STANDARD PARKING SPACES SHALL BE

MARKED IN WHITE AND BARRIER FREE SPACES IN BLUE. EACH BARRIER FREE SPACE SHALL

BE PROVIDED WITH A PAINTED PAVEMENT SYMBOL, A PRECAST CONCRETE BUMPER BLOCK,

AND A SIGN PER THE MANUAL OF UNIFORM TRAFFIC CONTROLS.

CATCH BASIN

SANITARY MANHOLE

STORM MANHOLE

CODED NOTES

1. CONCRETE TURNED DOWN SIDEWALK DETAIL #1C / C-501

2. SIDEWALK FLUSH TURN DOWN EDGE DETAIL #2C / C-501

3. BUILDING MOUNTED ACCESSIBLE PARKING SIGN DETAIL #1A / C-502

4. NOT USED

5. PREFABRICATED PEDESTRIAN BRIDGE WITH EXTERIOR STAIRS, REFER TO STRUCTURAL PLANS

6. SELF-SUPPORTING TOWER, 60 FT TALL WITH 6 ANTENNAS

6.1. 2 EA - 700/800 MHZ MONOPOLE

6.2. 3 EA - 136-174 MHZ MONOPOLE

6.3. 1 EA - 165-170 MHZ MONOPOLE

6.4. TOWER TO HAVE A LADDER OR SIMILAR MEANS FOR CLIMBING TO SUPPORT MAINTENANCE ACTIVITIES

6.5. FOUNDATIONS TO BE DESIGNED BY THE MANUFACTURER AND COORDINATED WITH THE GEOTECHNICAL

AND STRUCTURAL ENGINEER.

7. CONCRETE PAVEMENT STANDARD DUTY DETAIL #1D / C-501

8. CONCRETE SIDEWALK DETAIL #1A / C-501

9. ASPHALT PAVEMENT STANDARD DUTY DETAIL #1B / C-501

10. CONCRETE CURB. DETAIL #3D / C-501

11. CONCRETE WINGWALL, CAST IN PLACE (REPLACE IN KIND)

12. SIDEWALK CURB RAMP DETAIL #848.05 / C-501

13. CONCRETE CURB AND GUTTER DETAIL #2A / C-501

14. CONCRETE SPILLWAY DETAIL #4C / C-501

15. SEGMENTAL BLOCK RETAINING WALL WITH HANDRAIL OR EQUAL DETAIL #4A / C-502

16. CONCRETE STAIRS WITH HANDRAILS DETAIL #3C / C-501

17. ASPHALT PAVEMENT HEAVY DUTY DETAIL #2B / C-501

SIDEWALK CURB RAMP

CURB & GUTTER

BUILDING MOUNTED ACCESSIBLE PARKING SIGN

UTILITY SYSTEM INLINE CLEANOUT

LIMITS OF DISTURBANCE

CO

CURB

36.5'

ST

O

R M

S

EW

ER

IN

FI

LT

R

AT

IO

N

T R

EN

C

H

LIMITS OF STORM SEWER INFILTRATION TRENCH

VEGETATED SWALE

LAYDOWN AREA

ADDENDUM 0307/30/262

VIA ELECTRONIC TRANSMISSION

File details come from the government source that posted it. Updated .