The document is a technical cut sheet for US draft fans produced by Jeremias GmbH, specifically designed for the Kenton County Airport Board's (KCAB) Industrial HVAC Rehabilitation & Efficiency Program - Phase I project. The cut sheet details specifications for T9F-100 US Draft Fans with a 36" ID, 38.5" OD DWGV duct, featuring an open termination with screen, guy wire attachment points, and an anchor plate support. The detailed technical drawing provides comprehensive dimensional information, including fan sizes, weights, and configuration specifics for a CVG (Cincinnati/Northern Kentucky International Airport) stack and fan installation.
The technical specifications include multiple fan models (ranging from 8" to 36") with corresponding weight, length, and performance data. The project is part of a broader HVAC system replacement initiative that will update cooling towers, boilers, chiller equipment, emergency generators, electrical gear, pumps, and piping across four passenger buildings. The proposal submission deadline is set for Thursday, May 22, 2025, at 2:00 pm, with the goal of improving the airport's HVAC system efficiency. The cut sheet provides critical technical details that potential vendors would use to understand the precise requirements for fan installation and compatibility with the existing infrastructure.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
5 6 71 2 3 4
A
B
C
D
E
F
A
B
C
D
E je re m ia s G m b
H
A ll ri g h ts r e se rv e d a ls o r e g a rd in g a n y d is p o sa l, e xp lo ita tio n e d iti n g d is tr ib u tio n a s w e ll a s in t h e e ve n t o f a p p lic a tio n s fo r in d u st ri a l p ro p e rt y ri g h ts
Job:
format drawn by scale sheetPH1 inch / lb revisions-no.
PH1
namedate
US
1/28/2025 jreynolds
Customer:
project:
checked by
LEDGER
SMA
24041
JI - CVG Stacks - Fans -
QR
scan for reference
21'- 3 8 "
(CONNECT TO
COMMON DUCT)
36" ID, 38.5" OD
DWGV DUCT
ANCHOR PLATE SUPPORT
GUY WIRE ATTACHMENT POINT
US DRAFT FANS
T9F-100
OPEN TERMINATION
WITH SCREEN
" 8 7'-10 3
4'-3 5 8 "
Ben Garner Length Measurement 2'-6 1/4"
Ben Garner Length Measurement 15'-8 1/2"
Ben Garner Length Measurement 3'-2 1/4"
Ben Garner Image
Ben Garner Rectangle
Ben Garner Image
Ben Garner Callout
WEIGHT UNK
Ben Garner Image
File details come from the government source that posted it. Updated .