Exhibit_B_-_Assessment_Data_Envision_Field_Data_Sheets_Rev1.pdf

PDF 2 MB Posted

Attached to
Furnish & Install Equipment - Industrial HVAC Rehabilitation & Efficiency Program - Phase I
Solicitation number
25-027-ITB
Issued by
Kenton County, Kentucky

About this file

The document is a comprehensive set of detailed technical assessment data sheets for existing HVAC equipment at the Cincinnati/Northern Kentucky International Airport (CVG), prepared by MSD (Mechanical Systems Design). These field data sheets catalog the current boiler and cooling tower systems located in various mechanical rooms and roof areas across the airport's facilities, including Concourse B Basement, Main Terminal Basement, and Outside Ticketing areas. The data sheets provide exhaustive technical specifications for each piece of equipment, including model numbers, serial numbers, electrical characteristics, piping configurations, dimensions, and special installation notes.

The equipment inventory includes multiple Weil McLain boilers with varying serial numbers and configurations, primarily located in Boiler Rooms D112 and E102, and several cooling tower units (CT-CB-1 through CT-CB-8 on Concourse B Roof and CT-T3-1 through CT-T3-5 in the Outside Ticketing area). Each equipment profile documents critical technical details such as voltage/phase/hertz ratings, supply and return pipe sizes, insulation types, gas piping specifications, control valve types, and recommended maintenance actions. The comprehensive documentation suggests preparation for a systematic replacement and upgrade of the airport's HVAC infrastructure, aligning with the stated goal of the Industrial HVAC Rehabilitation & Efficiency Program - Phase I to replace main HVAC system components and improve overall system efficiency.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Concourse B Basement

Boiler Room D112

Weil Mclain - 2494

109259978

149" (L) x 60" (W) x 73" (H)

V/Ph/Hz: 460/3/60

See XOI for Panel Information

Size Supply 6"

Size Return 6"

Insulation 2" Fiber Glass

Header Size 8"

Size 3" Feed - 6" Header - 8" Main

Regulator P/N Armitrol 210e - 4 psi coming in

Size 22" inner, 24" Outer

Material Type Stainless

Routing Out Back of boiler- Tee to main

Pumps (2) Taco Base Mounted Shared- Replacement Recommended

Control Valves DDC Valves on HWS

Dampers/Act. On Flue of each boiler

Fans Exhaust for Boiler Room

Other

163" (L) x 70" (W)

48" Main

Exit Rear - Tee into main , main goes through floor to roof

HWS - Front, HWR- Back, Gas - Right Side

*As Builts Accurate

Double Door Exit - 71" x 83"

Make up Water - Into Supply Main

Newer Expansion Tanks - Reuse Recommended

10'x14' Removable Hatch in Chiller Room - Recommended Trans.

Combustion Aur for Boiler Room - 3'x21' Plenum *See Envision Photos/Videos for more information on pumps and accessories

Existing Boiler

Location/Room Number

Model Number

Serial Number

Dimensions

Electrical Data

Hydronic/Steam Piping

Natural Gas Piping

Venting

Remote Parts

Unit Pad or Steel Dimensions

General Info

Vent Orientation

Pipe Orientation

Special Notes

Weil Mclain - 2494

109259975

149" (L) x 60" (W) x 73" (H)

V/Ph/Hz: 460/3/60

See XOI for Panel Information

Size Supply 6"

Size Return 6"

Insulation 2" Fiber Glass

Header Size 8"

Size 3" Feed - 6" Header - 8" Main

Regulator P/N Armitrol 210e - 4 psi coming in

Size 22" inner, 24" Outer

Material Type Stainless

Routing Out Back of boiler- Tee to main

Pumps (2) Taco Base Mounted Shared- Replacement Recommended

Control Valves DDC Valves on HWS

Dampers/Act. On Flue of each boiler

Fans Exhaust for Boiler Room

Other

163" (L) x 70" (W)

48" Main

Exit Rear - Tee into main , main goes through floor to roof

HWS - Front, HWR- Back, Gas - Right Side

*As Builts Accurate

Double Door Exit - 71" x 83"

Make up Water - Into Supply Main

Newer Expansion Tanks - Reuse Recommended

10'x14' Removable Hatch in Chiller Room - Recommended Trans.

Combustion Aur for Boiler Room - 3'x21' Plenum *See Envision Photos/Videos for more information on pumps and accessories

Unit Pad or Steel Dimensions

General Info

Vent Orientation

Pipe Orientation

Special Notes

Venting

Remote Parts

Serial Number

Dimensions

Electrical Data

Hydronic/Steam Piping

Natural Gas Piping

Existing Boiler

Location/Room Number

Model Number

Size Supply

Size Return

Insulation

Header Size

Special Notes

Install Notes

How to Set

How to Pipe

How to Duct

Potential Issues

Dimensions

Electrical Data

Hydronic/Steam Piping

General Info

Vent Orientation

Pipe Orientation

New Boiler

Weil Mclain - 2494

109259974

149" (L) x 60" (W) x 73" (H)

V/Ph/Hz: 460/3/60

See XOI for Panel Information

Size Supply 6"

Size Return 6"

Insulation 2" Fiber Glass

Header Size 8"

Size 3" Feed - 6" Header - 8" Main

Regulator P/N Armitrol 210e - 4 psi coming in

Size 22" inner, 24" Outer

Material Type Stainless

Routing Out Back of boiler- Tee to main

Pumps (2) Taco Base Mounted Shared- Replacement Recommended

Control Valves DDC Valves on HWS

Dampers/Act. On Flue of each boiler

Fans Exhaust for Boiler Room

Other

163" (L) x 70" (W)

48" Main

Exit Rear - Tee into main , main goes through floor to roof

HWS - Front, HWR- Back, Gas - Right Side

*As Builts Accurate

Double Door Exit - 71" x 83"

Make up Water - Into Supply Main

Newer Expansion Tanks - Reuse Recommended

10'x14' Removable Hatch in Chiller Room - Recommended Trans.

Combustion Aur for Boiler Room - 3'x21' Plenum *See Envision Photos/Videos for more information on pumps and accessories

Unit Pad or Steel Dimensions

General Info

Vent Orientation

Pipe Orientation

Special Notes

Venting

Remote Parts

Serial Number

Dimensions

Electrical Data

Hydronic/Steam Piping

Natural Gas Piping

Existing Boiler

Insulation

Header Size

Special Notes

Install Notes

How to Set

How to Pipe

How to Duct

Potential Issues

Dimensions

Electrical Data

Hydronic/Steam Piping

General Info

Vent Orientation

Pipe Orientation

New Boiler

Weil Mclain - 2494

109259977

149" (L) x 60" (W) x 73" (H)

V/Ph/Hz: 460/3/60

See XOI for Panel Information

Size Supply 6"

Size Return 6"

Insulation 2" Fiber Glass

Header Size 8"

Size 3" Feed - 6" Header - 8" Main

Regulator P/N Armitrol 210e - 4 psi coming in

Size 22" inner, 24" Outer

Material Type Stainless

Routing Out Back of boiler- Tee to main

Pumps (2) Taco Base Mounted Shared- Replacement Recommended

Control Valves DDC Valves on HWS

Dampers/Act. On Flue of each boiler

Fans Exhaust for Boiler Room

Other

163" (L) x 70" (W)

48" Main

Exit Rear - Tee into main , main goes through floor to roof

HWS - Front, HWR- Back, Gas - Right Side

*As Builts Accurate

Double Door Exit - 71" x 83"

Make up Water - Into Supply Main

Newer Expansion Tanks - Reuse Recommended

10'x14' Removable Hatch in Chiller Room - Recommended Trans.

Combustion Aur for Boiler Room - 3'x21' Plenum *See Envision Photos/Videos for more information on pumps and accessories

Unit Pad or Steel Dimensions

General Info

Vent Orientation

Pipe Orientation

Special Notes

Venting

Remote Parts

Serial Number

Dimensions

Electrical Data

Hydronic/Steam Piping

Natural Gas Piping

Existing Boiler

Insulation

Header Size

Special Notes

Install Notes

How to Set

How to Pipe

How to Duct

Potential Issues

Dimensions

Electrical Data

Hydronic/Steam Piping

General Info

Vent Orientation

Pipe Orientation

New Boiler

Weil Mclain - 2494

109259976

149" (L) x 60" (W) x 73" (H)

V/Ph/Hz: 460/3/60

See XOI for Panel Information

Size Supply 6"

Size Return 6"

Insulation 2" Fiber Glass

Header Size 8"

Size 3" Feed - 6" Header - 8" Main

Regulator P/N Armitrol 210e - 4 psi coming in

Size 22" inner, 24" Outer

Material Type Stainless

Routing Out Back of boiler- Tee to main

Pumps (2) Taco Base Mounted Shared- Replacement Recommended

Control Valves DDC Valves on HWS

Dampers/Act. On Flue of each boiler

Fans Exhaust for Boiler Room

Other

163" (L) x 70" (W)

48" Main

Exit Rear - Tee into main , main goes through floor to roof

HWS - Front, HWR- Back, Gas - Right Side

*As Builts Accurate

Double Door Exit - 71" x 83"

Make up Water - Into Supply Main

Newer Expansion Tanks - Reuse Recommended

10'x14' Removable Hatch in Chiller Room - Recommended Trans.

Combustion Aur for Boiler Room - 3'x21' Plenum *See Envision Photos/Videos for more information on pumps and accessories

Unit Pad or Steel Dimensions

General Info

Vent Orientation

Pipe Orientation

Special Notes

Venting

Remote Parts

Serial Number

Dimensions

Electrical Data

Hydronic/Steam Piping

Natural Gas Piping

Existing Boiler

Insulation

Header Size

Special Notes

Install Notes

How to Set

How to Pipe

How to Duct

Potential Issues

Dimensions

Electrical Data

Hydronic/Steam Piping

General Info

Vent Orientation

Pipe Orientation

New Boiler

Main Terminal Basement

Boiler Room E102

Tag: B-TD-1

M/N: Weil Mclain WCR4-G-30

109259980

124.5" (L) x 61" (W) x 73" (H)

V/Ph/Hz: 460/3/60

30 Amp Breaker

Size Supply 6"

Size Return 6"

Insulation 2" Fiber Glass

Header Size 8"

Size 2.5" to a 6" main

Regulator P/N Maxitrol RV11 - 4" LF 6" HF - Current Gas pressure feeding Mech Room: 4.5 psi

Size 22" Outer Wall, 20" Inner Wall

Material Type SS Inner/ Galvanized Outer

Routing Vertical up to tee, Venting Out Side Wall

Pumps (2) Taco Base Mounted Shared- Replacement Recommended

Control Valves 2 way valve on HWR DDC

Dampers/Act. Combustion Air on Wall/Vent in flue

Fans Space has exhaust

Concrete Pad: 132" (L) x 69" (W)

Tee-to-One as per as-built

*Follow current routing with new boiler

Supply in front, Return in Back

*Follow current routing with new boiler

Special Notes

Existing Boiler

Location/Room Number

Model Number

180 degree Operating Temperature HF 160 degree LF Combustion air through OA louver in wall Rigging through knockdown wall, remove partition

1" MOW

*As-Builts are accurate *See XOI Photos/Videos for more information on pumps and accessories

Venting

Remote Parts

Serial Number

Dimensions

Hydronic/Steam Piping

Natural Gas Piping

Electrical Data

Breaker Data

Unit Pad or Steel Dimensions

General Info

Vent Orientation

Tag: B-TD-2

M/N: Weil Mclain WCR4-G-30

109259979

124.5" (L) x 61" (W) x 73" (H)

V/Ph/Hz: 460/3/60

30 Amp Breaker

Size Supply 6"

Size Return 6"

Insulation 2" Fiber Glass

Header Size 8"

Size 2.5" to a 6" main

Regulator P/N Maxitrol RV11 - 4" LF 6" HF - Current Gas pressure feeding Mech Room: 4.5 psi

Size 22" Outer Wall, 20" Inner Wall

Material Type SS Inner/ Galvanized Outer

Routing Vertical up to tee, Venting Out Side Wall

Pumps (2) Taco Base Mounted Shared- Replacement Recommended

Control Valves 2 way valve on HWR DDC

Dampers/Act. Combustion Air on Wall/Vent in flue

Fans Space has exhaust

Concrete Pad: 132" (L) x 69" (W)

Tee-to-One as per as-built

*Follow current routing with new boiler

Supply in front, Return in Back

*Follow current routing with new boiler

Special Notes

Existing Boiler

Location/Room Number

Model Number

180 degree Operating Temperature HF 160 degree LF Combustion air through OA louver in wall Rigging through knockdown wall, remove partition

1" MOW

*As-Builts are accurate *See XOI Photos/Videos for more information on pumps and accessories

Venting

Remote Parts

Serial Number

Dimensions

Hydronic/Steam Piping

Natural Gas Piping

Electrical Data

Breaker Data

Unit Pad or Steel Dimensions

General Info

Tag: B-TD-3

M/N: Weil Mclain WCR4-G-30

109259981

124.5" (L) x 61" (W) x 73" (H)

V/Ph/Hz: 460/3/60

60 Amp Breaker

Size Supply 6"

Size Return 6"

Insulation 2" Fiber Glass

Header Size 8"

Size 2.5" to a 6" main

Regulator P/N Maxitrol RV11 - 4" LF 6" HF - Current Gas pressure feeding Mech Room: 4.5 psi

Size 22" Outer Wall, 20" Inner Wall

Material Type SS Inner/ Galvanized Outer

Routing Vertical up to tee, Venting Out Side Wall

Pumps (2) Taco Base Mounted Shared- Replacement Recommended

Control Valves 2 way valve on HWR DDC

Dampers/Act. Combustion Air on Wall/Vent in flue

Fans Space has exhaust

Concrete Pad: 132" (L) x 69" (W)

Tee-to-One as per as-built

*Follow current routing with new boiler

Supply in front, Return in Back

*Follow current routing with new boiler

Special Notes

Existing Boiler

Location/Room Number

Model Number

Boilers 1 and 2 have 30 AMP Breakers, Boiler B-TD-3 has an added air compressor and a 60 AMP Breaker 180 degree Operating Temperature HF - 160 degree LF Combustion air through OA louver in wall Rigging through knockdown wall, remove partition

1" MOW

*As-Builts are accurate See XOI Photos/Videos for more information on pumps and accessories

Venting

Remote Parts

Serial Number

Dimensions

Hydronic/Steam Piping

Natural Gas Piping

Electrical Data

Breaker Data

Unit Pad or Steel Dimensions

General Info

Concourse B Roof

Cooling Tower Yard

CT-CB-1

NC5033205

N/a

(2) Cooling Towers in Tadem: 271" (L) x 225" (W)

65" Cleareance between each set of towers

460/3/60

Size Supply/Return Foil Wrapped in Mech Room - 20" - 10" at the pump

Insulation Fiber w/Aluminum Jacket

Heat Trace No

Makeup Water Inside Chiller Plant with Pumps

Pumps See Envision

Control Valves Modulating DDC Valve on Main Supply

Dampers/Act.

Fans 1 Fan on top of each cell

Other

271" x 213" (for each pair)

See Below for Detailed Steel:

Fed from Below Tower (Leaving)

Supply From Top (Entering) Units sit outside on Roof

Cooling Towers are not labelled individually

Structural Steel Layout:

Existing Cooling Tower

Location/Room Number

Model Number

Serial Number

Dimensions

Hydronic/ Piping

Remote Parts

Electrical Data (V/Ph/Hz)

Special Notes

Unit Pad or Steel Dimensions

General Info Pipe Orientation

CT-CB-2

NC5033205

N/a

(2) Cooling Towers in Tadem: 271" (L) x 225" (W)

65" Cleareance between each set of towers

460/3/60

Size Supply/Return Foil Wrapped in Mech Room - 20" - 10" at the pump

Insulation Fiber w/Aluminum Jacket

Heat Trace No

Makeup Water Inside Chiller Plant with Pumps

Pumps See Envision

Control Valves Modulating DDC Valve on Main Supply

Dampers/Act.

Fans 1 Fan on top of each cell

Other

271" x 213" (for each pair)

See Below for Detailed Steel:

Fed from Below Tower (Leaving)

Supply From Top (Entering) Units sit outside on Roof

Cooling Towers are not labelled individually

Structural Steel Layout:

Hydronic/ Piping

Remote Parts

Unit Pad or Steel Dimensions

General Info Pipe Orientation

Special Notes

Existing Cooling Tower

Location/Room Number

Model Number

Serial Number

Dimensions

Electrical Data (V/Ph/Hz)

CT-CB-3

NC5033205

N/a

(2) Cooling Towers in Tadem: 271" (L) x 225" (W)

65" Cleareance between each set of towers

460/3/60

Size Supply/Return Foil Wrapped in Mech Room - 20" - 10" at the pump

Insulation Fiber w/Aluminum Jacket

Heat Trace No

Makeup Water Inside Chiller Plant with Pumps

Pumps See Envision

Control Valves Modulating DDC Valve on Main Supply

Dampers/Act.

Fans 1 Fan on top of each cell

Other

271" x 213" (for each pair)

See Below for Detailed Steel:

Fed from Below Tower (Leaving)

Supply From Top (Entering) Units sit outside on Roof

Cooling Towers are not labelled individually

Structural Steel Layout:

Hydronic/ Piping

Remote Parts

Unit Pad or Steel Dimensions

General Info Pipe Orientation

Special Notes

Existing Cooling Tower

Location/Room Number

Model Number

Serial Number

CT-CB-4

NC5033205

N/a

(2) Cooling Towers in Tadem: 271" (L) x 225" (W)

65" Cleareance between each set of towers

460/3/60

Size Supply/Return Foil Wrapped in Mech Room - 20" - 10" at the pump

Insulation Fiber w/Aluminum Jacket

Heat Trace No

Makeup Water Inside Chiller Plant with Pumps

Pumps See Envision

Control Valves Modulating DDC Valve on Main Supply

Dampers/Act.

Fans 1 Fan on top of each cell

Other

271" x 213" (for each pair)

See Below for Detailed Steel:

Fed from Below Tower (Leaving)

Supply From Top (Entering) Units sit outside on Roof

Cooling Towers are not labelled individually

Structural Steel Layout:

Hydronic/ Piping

Remote Parts

Unit Pad or Steel Dimensions

General Info Pipe Orientation

Special Notes

Existing Cooling Tower

Location/Room Number

Model Number

Serial Number

CT-CB-5

NC5033205

N/a

(2) Cooling Towers in Tadem: 271" (L) x 225" (W)

65" Cleareance between each set of towers

460/3/60

Size Supply/Return Foil Wrapped in Mech Room - 20" - 10" at the pump

Insulation Fiber w/Aluminum Jacket

Heat Trace No

Makeup Water Inside Chiller Plant with Pumps

Pumps See Envision

Control Valves Modulating DDC Valve on Main Supply

Dampers/Act.

Fans 1 Fan on top of each cell

Other

271" x 213" (for each pair)

See Below for Detailed Steel:

Fed from Below Tower (Leaving)

Supply From Top (Entering) Units sit outside on Roof

Cooling Towers are not labelled individually

Structural Steel Layout:

Hydronic/ Piping

Remote Parts

Unit Pad or Steel Dimensions

General Info Pipe Orientation

Special Notes

Existing Cooling Tower

Location/Room Number

Model Number

Serial Number

CT-CB-6

NC5033205

N/a

(2) Cooling Towers in Tadem: 271" (L) x 225" (W)

65" Cleareance between each set of towers

460/3/60

Size Supply/Return Foil Wrapped in Mech Room - 20" - 10" at the pump

Insulation Fiber w/Aluminum Jacket

Heat Trace No

Makeup Water Inside Chiller Plant with Pumps

Pumps See Envision

Control Valves Modulating DDC Valve on Main Supply

Dampers/Act.

Fans 1 Fan on top of each cell

Other

271" x 213" (for each pair)

See Below for Detailed Steel:

Fed from Below Tower (Leaving)

Supply From Top (Entering) Units sit outside on Roof

Cooling Towers are not labelled individually

Structural Steel Layout:

Hydronic/ Piping

Remote Parts

Unit Pad or Steel Dimensions

General Info Pipe Orientation

Special Notes

Existing Cooling Tower

Location/Room Number

Model Number

Serial Number

CT-CB-7

NC5033205

N/a

(2) Cooling Towers in Tadem: 271" (L) x 225" (W)

65" Cleareance between each set of towers

460/3/60

Size Supply/Return Foil Wrapped in Mech Room - 20" - 10" at the pump

Insulation Fiber w/Aluminum Jacket

Heat Trace No

Makeup Water Inside Chiller Plant with Pumps

Pumps See Envision

Control Valves Modulating DDC Valve on Main Supply

Dampers/Act.

Fans 1 Fan on top of each cell

Other

271" x 213" (for each pair)

See Below for Detailed Steel:

Fed from Below Tower (Leaving)

Supply From Top (Entering) Units sit outside on Roof

Cooling Towers are not labelled individually

Structural Steel Layout:

Hydronic/ Piping

Remote Parts

Unit Pad or Steel Dimensions

General Info Pipe Orientation

Special Notes

Existing Cooling Tower

Location/Room Number

Model Number

Serial Number

CT-CB-8

NC5033205

N/a

(2) Cooling Towers in Tadem: 271" (L) x 225" (W)

65" Cleareance between each set of towers

460/3/60

Size Supply/Return Foil Wrapped in Mech Room - 20" - 10" at the pump

Insulation Fiber w/Aluminum Jacket

Heat Trace No

Makeup Water Inside Chiller Plant with Pumps

Pumps See Envision

Control Valves Modulating DDC Valve on Main Supply

Dampers/Act.

Fans 1 Fan on top of each cell

Other

271" x 213" (for each pair)

See Below for Detailed Steel:

Fed from Below Tower (Leaving)

Supply From Top (Entering) Units sit outside on Roof

Cooling Towers are not labelled individually

Structural Steel Layout:

Hydronic/ Piping

Remote Parts

Unit Pad or Steel Dimensions

General Info Pipe Orientation

Special Notes

Existing Cooling Tower

Location/Room Number

Model Number

Serial Number

Outside Ticketing

CT-T3-1

NC7034GS

029478-003-93

(2) Cooling Towers in Tadem: 262" (L) x 183" (W)

262" x 183"

460/3/60

Size Supply/Return

Insulation Fiber w/Aluminum Jacket

Heat Trace Yes

Makeup Water Inside Chiller Plant with Pumps

Pumps See Envision for more

Control Valves DDC w/ manual bypass

Dampers/Act. No

Fans On Tower

Other

See Below:

Fed from Below Tower (Leaving)

Supply From Top (Entering)

Special Notes

Units sit outside on ground level Structural Steel Layout:

Unit Pad or Steel Dimensions

General Info

Pipe Orientation

Other

Serial Number

Dimensions

Electrical Data (V/Ph/Hz)

Hydronic/ Piping

Remote Parts

Existing Cooling Tower

CT-T3-2

NC7034GS

029478-003-93

(2) Cooling Towers in Tadem: 262" (L) x 183" (W)

262" x 183"

460/3/60

Size Supply/Return

Insulation Fiber w/Aluminum Jacket

Heat Trace Yes

Makeup Water Inside Chiller Plant with Pumps

Pumps See Envision for more

Control Valves DDC w/ manual bypass

Dampers/Act. No

Fans On Tower

Other

See Below:

Fed from Below Tower (Leaving)

Supply From Top (Entering)

Special Notes

Units sit outside on ground level Structural Steel Layout:

Hydronic/ Piping

Remote Parts

Unit Pad or Steel Dimensions

General Info

Pipe Orientation

Other

Existing Cooling Tower

Location/Room Number

Model Number

Serial Number

CT-T3-3

NC7034GS

029478-003-93

(2) Cooling Towers in Tadem: 262" (L) x 183" (W)

262" x 183"

460/3/60

Size Supply/Return

Insulation Fiber w/Aluminum Jacket

Heat Trace Yes

Makeup Water Inside Chiller Plant with Pumps

Pumps See Envision for more

Control Valves DDC w/ manual bypass

Dampers/Act. No

Fans On Tower

Other

See Below:

Fed from Below Tower (Leaving)

Supply From Top (Entering)

Special Notes

Units sit outside on ground level Structural Steel Layout:

Hydronic/ Piping

Remote Parts

Unit Pad or Steel Dimensions

General Info

Pipe Orientation

Other

Existing Cooling Tower

Location/Room Number

Model Number

Serial Number

CT-T3-4

NC7034GS

029478-003-93

(2) Cooling Towers in Tadem: 262" (L) x 183" (W)

262" x 183"

460/3/60

Size Supply/Return

Insulation Fiber w/Aluminum Jacket

Heat Trace Yes

Makeup Water Inside Chiller Plant with Pumps

Pumps See Envision for more

Control Valves DDC w/ manual bypass

Dampers/Act. No

Fans On Tower

Other

See Below:

Fed from Below Tower (Leaving)

Supply From Top (Entering)

Special Notes

Units sit outside on ground level Structural Steel Layout:

Hydronic/ Piping

Remote Parts

Unit Pad or Steel Dimensions

General Info

Pipe Orientation

Other

Existing Cooling Tower

Location/Room Number

Model Number

Serial Number

CT-T3-5

No Data Tag Visible

No Data Tag Visible

168" (L) x 269" (W)

460/3/60

Size Supply/Return

Insulation Fiber w/Aluminum Jacket

Heat Trace Yes

Makeup Water Inside Chiller Plant with Pumps

Pumps See Envision for more

Control Valves DDC w/ manual bypass

Dampers/Act. No

Fans On Tower

Other

See Below:

Fed from Below Tower (Leaving)

Supply From Top (Entering)

Special Notes

Units sit outside on ground level Structural Steel Layout:

Hydronic/ Piping

Remote Parts

Unit Pad or Steel Dimensions

General Info

Pipe Orientation

Other

Existing Cooling Tower

Location/Room Number

Model Number

Serial Number

Boiler B-CB-1 Form
Boiler B-CB-2 Form
Boiler B-CB-3 Form
Boiler B-CB-4 Form
Boiler B-CB-5 Form
Boiler B-TD-1 Form
Boiler B-TD-2 Form
Boiler B-TD-3 Form
Cooling Tower CT-CB-1
Cooling Tower CT-CB-2
Cooling Tower CT-CB-3
Cooling Tower CT-CB-4
Cooling Tower CT-CB-5
Cooling Tower CT-CB-6
Cooling Tower CT-CB-7
Cooling Tower CT-CB-8
Cooling Tower CT-T3-1
Cooling Tower CT-T3-2
Cooling Tower CT-T3-3
Cooling Tower CT-T3-4
Cooling Tower CT-T3-5
AHU-CA-01
AHU-CA-02
AHU-CA-03
AHU-CA-04
AHU-CA-05
AHU-CA-06
AHU-CA-08
AHU-CA-13
AHU-CA-14
AHU-CA-AG4
AHU-CB-04
AHU-CB-05
AHU-CB-06
AHU-CB-07
AHU-CB-08
AHU-CB-09
AHU-CB-10
AHU-CB-11
AHU-CB-12
AHU-CB-13
AHU-CB-14
AHU-CB-15
AHU-CB-16
AHU-CB-17
AHU-CB-18
AHU-CB-19
AHU-CB-21
AHU-CB-22
AHU-CB-26
AHU-CB-27
AHU-CB-38
AHU-CB-39
AHU-AG3
AHU-CB-AG5
AHU-T3-16
RTU-CA-1
RTU-CA-2

File details come from the government source that posted it. Updated .