Ultrasonic Thickness Measurements 2011.pdf
PDF 299 KB Posted
- Solicitation number
- ADF&G FY27 RV Medeia Shipyard Services - Request for Information (RFI)
- Issued by
- Alaska
About this file
This is a Thickness Measurement Report (TM-6) prepared by Elander Inspection Ltd., a nondestructive testing and marine inspection company based in Richmond, British Columbia, documenting ultrasonic thickness measurements conducted on the R.V. Medeia on March 17, 2011. The report (E11-018-004) provides comprehensive thickness measurements of miscellaneous structural members and various piping systems aboard the vessel, including suction and discharge manifolds, overboard penetrations, sewage piping, bilge pump piping, and fuel tank piping systems. The measurements were taken at multiple locations throughout the vessel including the engine room, void spaces, and fuel tank areas, with structured documentation of port and starboard locations where applicable. Original thicknesses are referenced against class minimum thickness requirements, with gauged readings compared to these standards to calculate diminution percentages indicating corrosion or wear.
The report presents detailed thickness data organized by structural location and pipe designation, with measurements provided in inches and diminution calculated as both absolute values and percentages of original thickness. Multiple pipe schedules are documented, including 4-inch Schedule 80 pipes, 4-inch Schedule 40 pipes, 2-inch Schedule 80 pipes, and 1.25-inch Schedule 80 pipes, with measurements taken at top, bottom, inboard, and outboard positions on horizontal pipes and at multiple circumferential locations on vessel components. The report includes a general note that all original thicknesses used are to be confirmed by original ship drawings and should not be used without first confirming actual thickness, and notes that diminution calculations were not possible for data lacking original thickness values. The comprehensive assessment identifies several areas of significant corrosion, with some measurements showing diminution percentages exceeding 50 percent in specific locations.
View the file
Other files
Show all 49
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
THICKNESS MEASUREMENT REPORT - TM-6
REPORT ON THICKNESS MEASUREMENT OF MISCELLANEOUS STRUCTURAL MEMBERS
Substantial corr
Ship's Name: Id.No: Legend: Below class min
Port Stbd
Inches Sch. Inches Inches Inches Inches Inches % Inches %
S1 Top Box 0.375 0.263 0.350 0.341 0.03 6.7% 0.03 9.1% GENERAL NOTE: ALL ORIGINAL
Aft Box 0.375 0.263 0.366 0.345 0.01 2.4% 0.03 8.0% THICKNESSES USED IN THIS
Btm Box 0.375 0.263 0.369 0.327 0.01 1.7% 0.05 12.8% REPORT ARE TO BE CONFIRMED
- - BY ORIGINAL SHIPS' DWGS
S2 Top Box 0.375 0.263 0.381 - 0.00 0.0%
Aft Box 0.375 0.263 0.333 - 0.04 11.2% DO NOT USE THE REFERENCED
Btm Box 0.375 0.263 0.359 - 0.02 4.3% THICKNESES WITHOUT FIRST
- - CONFIRMING THE ACUTAL
- - THICKNESS.
O1 Top Box 0.375 0.263 0.316 0.373 0.06 15.7% 0.00 0.5%
Aft Box 0.375 0.263 0.338 0.334 0.04 9.9% 0.04 10.9% DIMINUTION CALCULATIONS
Btm Box 0.375 0.263 0.342 0.341 0.03 8.8% 0.03 9.1% WAS NOT POSSIBLE FOR DATA
- - WITH NO ORIGINAL THICKNESS
O2 Top Box 0.375 0.263 0.383 - 0.00 0.0%
Aft Box 0.375 0.263 0.338 - 0.04 9.9%
Btm Box 0.375 0.263 0.345 - 0.03 8.0%
P1 0.000 0.250 - -
P2 0.000 0.242 - -
P3 0.000 0.278 - -
P4 0.000 0.238 - -
P5 0.000 0.128 - -
P6 0.000 0.248 -
P7 0.000 0.238 -
P8 0.000 0.245 -
Suction Manifold Pipe
Pipe - 1st from manifold
Pipe - 1st from manifold
Pipe - 1st from manifold
Pipe - 1st from manifold
Pipe - 1st from manifold
Pipe - 1st from manifold
Pipe - 1st from manifold
Pipe - 1st from manifold
Pipe - 1st from manifold
Discharge Manifold
Top Plate, Aft Plate
Btm Plate
Drawing/CommentsPort Starboard
Suction Manifold
Top Plate, Pipe Size Pipe Sch.
Location of Structure: Void/Engine Room/Fuel Tanks Frame No. n/a
Description Element /
Frame No.
Draw ref.
Orig thk.
Class min thk.
Gauged
R.v. Medeia N/A Report No: E11-018-004
Description: Various Piping Systems
Diminution
Top Plate, Aft Plate
Btm Plate
Aft Plate
Btm Plate
Top Plate, Aft Plate
Btm Plate
ELANDER INSPECTION LTD.
Suite 128 – 11800 River Road, Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca Web Page: Elanderinspection.ca Nondestructive Testing and Marine Inspection
R.V. Medeia - UTM Piping ELANDER INSPECTION LTD. March 17, 2011
Ship's Name: Id.No: Legend: Below class minR.v. Medeia N/A Report No: E11-018-004
Description: Various Piping Systems
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca Web Page: Elanderinspection.ca Nondestructive Testing and Marine Inspection
D1 0.000 0.240 - -
D2 0.000 0.246 - -
D3 0.000 0.241 - -
D4 0.000 0.255 - -
D5 0.000 0.178 - -
D6 0.000 0.242 - -
D7 0.000 0.258 - -
D8 0.000 0.234 - -
0.000
Top 1 0.000 0.177 - -
Btm 1 0.000 0.182 - -
Top 2 0.000 0.177 - -
Btm 2 0.000 0.182 - -
Top 3 0.000 0.179 - -
Btm 3 0.000 0.196 - -
Top 0.500 0.337 0.236 0.490 0.00 0.0% - Original thickness estimated
Top 0.500 0.337 0.236 0.496 0.00 0.0% - Original thickness estimated
Side 0.500 0.337 0.236 0.460 - 0.00 0.0% Original thickness estimated
Side 0.500 0.337 0.236 0.465 - 0.00 0.0% Original thickness estimated
Side 0.500 0.337 0.236 0.467 - 0.00 0.0% Original thickness estimated
Top 0.000 0.260 - -
Btm 0.000 0.265 - -
Pipe - 1st from manifold
Pipe - 1st from manifold
Pipe - 1st from manifold
Pipe - 1st from manifold
(Area tested from E/R Aft - 10' )
Fwd Nozzle
Sea Chest
Main Body and frm Fwd BHD + 10' Approx)
40' of Pipe from Manifold
Discharge Manifold Pipe
Pipe - 1st from manifold
Pipe - 1st from manifold
Pipe - 1st from manifold
Pipe - 1st from manifold
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca Web Page: Elanderinspection.ca Nondestructive Testing and Marine Inspection
Inbd B1 0.337 0.236 0.260 0.08 22.8%
Aft B1 0.337 0.236 0.272 0.07 19.3%
Top B2 0.337 0.236 0.286 0.05 15.1% -
Btm B2 0.337 0.236 0.262 0.08 22.3% -
Top B3 0.337 0.236 0.289 0.05 14.2% -
Top B3 0.337 0.236 0.268 0.07 20.5% -
Fwd B4 0.337 0.236 0.268 0.07 20.5% -
Side B4 0.337 0.236 0.258 0.08 23.4% -
0.000 0.199 - -
0.000 0.201 - -
0.000 0.184 - -
0.000 0.180 - -
0.000 0.167 - -
0.000 0.162 - -
Top 0.000 0.284 - -
Aft Side 0.000 0.277 - -
0.000 - -
OB-1 4 Sch. 80 0.337 0.236 0.279 - 0.06 17.2%
4 Sch. 80 0.337 0.236 0.244 - 0.09 27.6% ds - -
OB-2 4 Sch. 80 0.337 0.236 0.262 0.08 22.3%
4 Sch. 80 0.337 0.236 0.268 0.07 20.5%
4 Sch. 80 0.337 0.236 0.282 0.06 16.3%
OB-3 4 Sch. 80 0.337 0.236 0.175 - 0.16 48.1%
4 Sch. 80 0.337 0.236 0.179 - 0.16 46.9%
4 Sch. 80 0.337 0.236 0.148 - 0.19 56.1%
OB-4 4 Sch. 80 0.337 0.236 0.285 - 0.05 15.4%
4 Sch. 80 0.337 0.236 0.249 - 0.09 26.1%
Vertical Pipe below Elbow going to Tank
Horizontal pipe after Fwd BHD
Discharge Pipe
Hortizontal Pipe going fwd
Aft of Fwd BHD
90 degree Elbow aft of Valve
Pipe System in Area of Overboard
Void Space Overboard Penetrations
1st Fwd (Fwd BHD)
1st Fwd
2nd Fwd
2nd Fwd
3rd Fwd
3rd Fwd (Aft. BHD)
Sewage Pipe Through-hull
Fwd Nozzle
Bildge Pump and Piping
90 Degree Elbow
Vertical Pipe below Elbow
Vertical pipe above pump
Vertical pipe above pump
Fwd Nozzle
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca Web Page: Elanderinspection.ca Nondestructive Testing and Marine Inspection
1 Top 4 Sch. 80 0.337 0.236 0.174 0.16 48.4% -
Side 4 Sch. 80 0.337 0.236 0.212 0.13 37.1% -
Btm 4 Sch. 80 0.337 0.236 0.206 0.13 38.9% -
Outbd Radius - -
2 Top 4 Sch. 80 0.337 0.236 0.340 0.00 0.0% -
Btm 4 Sch. 80 0.337 0.236 0.349 0.00 0.0% -
3 Top 4 Sch. 80 0.337 0.236 0.297 0.04 11.9% -
Btm 4 Sch. 80 0.337 0.236 0.271 0.07 19.6% -
SD-1 Top 4 Sch. 80 0.337 0.236 0.258 - 0.08 23.4%
Inbd 4 Sch. 80 0.337 0.236 0.274 - 0.06 18.7%
Btm 4 Sch. 80 0.337 0.236 0.274 - 0.06 18.7%
Outbd 4 Sch. 80 0.337 0.236 0.265 - 0.07 21.4%
SD-2 Top 4 Sch. 80 0.337 0.236 0.212 - 0.13 37.1%
Inbd 4 Sch. 80 0.337 0.236 0.197 - 0.14 41.5%
Btm 4 Sch. 80 0.337 0.236 0.202 - 0.14 40.1%
Outbd 4 Sch. 80 0.337 0.236 0.202 - 0.14 40.1%
SD-3 Top 4 Sch. 80 0.337 0.236 0.265 - 0.07 21.4%
Inbd 4 Sch. 80 0.337 0.236 0.264 - 0.07 21.7%
Btm 4 Sch. 80 0.337 0.236 0.274 - 0.06 18.7%
Outbd 4 Sch. 80 0.337 0.236 0.264 - 0.07 21.7%
SD-4 Top 4 Sch. 80 0.337 0.236 0.285 - 0.05 15.4%
Inbd 4 Sch. 80 0.337 0.236 0.275 - 0.06 18.4%
Btm 4 Sch. 80 0.337 0.236 0.268 - 0.07 20.5%
Outbd 4 Sch. 80 0.337 0.236 - -
Horizontal Pipe going Aft
Horizontal pipe going Inbd.
Horizontal Pipe past Loc. 3
90 Degree Elbow
90 degree Elbow Fwd of reducer
Sewage discharge Pipe in Closet
Horizontall Pipe
Waste Water to Tank located in Fwd Berth Area (Port side)
Pipe aft of reducer
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca Web Page: Elanderinspection.ca Nondestructive Testing and Marine Inspection
SD-5 Top 4 Sch. 80 0.337 0.236 0.265 - 0.07 21.4%
Inbd 4 Sch. 80 0.337 0.236 0.240 - 0.10 28.8%
Btm Sch. 80 0.337 0.236 0.247 - 0.09 26.7%
Outbd Sch. 80 0.337 0.236 0.240 - 0.10 28.8%
SD-6 Fwd Sch. 80 0.337 0.236 0.275 - 0.06 18.4%
Aft Sch. 80 0.337 0.236 0.280 - 0.06 16.9%
Top 4" Sch 40 0.237 0.166 0.242 0.00 0.0% - Pipes identified Fwd to Aft
Btm 4" Sch 40 0.237 0.166 0.267 0.00 0.0% -
Top 4" Sch 40 0.237 0.166 0.210 0.03 11.4% -
Btm Sch 40 0.204 0.143 0.209 0.00 0.0% -
Top 1 1/4" Sch 80 0.190 0.133 0.197 0.00 0.0% -
Btm 1 1/4" Sch 80 0.190 0.133 0.172 0.02 9.5% -
Top 0.237 0.166 0.275 0.00 0.0% -
Btm 0.237 0.166 0.255 0.00 0.0% -
Top 0.187 0.131 0.172 0.171 0.02 8.0% 0.02 8.6%
Middle 0.187 0.131 0.177 0.191 0.01 5.3% 0.00 0.0%
Middle 0.187 0.131 0.181 0.180 0.01 3.2% 0.01 3.7%
Btm 0.187 0.131 0.180 0.169 0.01 3.7% 0.02 9.6%
Top 0.187 0.131 ds 0.214 - 0.00 0.0%
Aft Side 0.187 0.131 0.200 0.195 0.00 0.0% 0.00 0.0%
Btm 0.187 0.131 0.164 0.176 0.02 12.3% 0.01 5.9%
Top 0.187 0.131 0.190 0.00 0.0% -
Aft Side 0.187 0.131 0.172 0.02 8.0% -
Btm 0.187 0.131 0.168 0.02 10.2% -
Top 0.187 0.131 0.164 0.172 0.02 12.3% 0.02 8.0%
Middle 0.187 0.131 0.170 0.165 0.02 9.1% 0.02 11.8%
Middle 0.187 0.131 0.168 0.165 0.02 10.2% 0.02 11.8%
Btm 0.187 0.131 0.176 0.164 0.01 5.9% 0.02 12.3%
Outboard Head
Outboard Head
Shell Circ 1
Shell Circ 1
Shell Circ 1
Air Receivers
Shell Circ 2
Shell Circ 2
Shell Circ 2
Inboard Head
Inboard Head
Inboard Head
Inboard Head
Outboard Head
Outboard Head
2nd Fwd
3rd Fwd
3rd Fwd
4th Fwd
4th Fwd
Engine Room Overboad Discharge Pipe
1st Fwd
1st Fwd
2nd Fwd
Vertical Pipe below Elbow
Upper hoizontal Pipe
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca
Top 2" Sch. 80 0.218 0.153 0.196 0.02 10.1% -
Outbd 0.218 0.153 0.177 0.04 18.8% -
Btm 0.218 0.153 0.196 0.02 10.1% -
Inbod 0.218 0.153 0.195 0.02 10.6% -
Top 2" Sch. 80 0.218 0.153 0.209 0.01 4.1% -
Outbd 0.218 0.153 0.201 0.02 7.8% -
Btm 0.218 0.153 0.197 0.02 9.6% -
Inbod 0.218 0.153 0.213 0.01 2.3% -
Top 2" Sch. 80 0.218 0.153 0.190 0.03 12.8% -
Outbd 0.218 0.153 0.191 0.03 12.4% -
Btm 0.218 0.153 0.193 0.03 11.5% -
Inbod 0.218 0.153 0.198 0.02 9.2% -
Top 2" Sch. 80 0.218 0.153 0.223 0.00 0.0% -
Outbd 0.218 0.153 0.212 0.01 2.9% -
Btm 0.218 0.153 0.217 0.00 0.5% -
Inbod 0.218 0.153 0.216 0.00 0.9% -
Top 2" Sch. 80 0.218 0.153 0.201 0.02 7.8% -
Outbd 0.218 0.153 0.211 0.01 3.2% -
Btm 0.218 0.153 0.219 0.00 0.0% -
Inbod 0.218 0.153 0.218 0.00 0.0% -
Top 2" Sch. 80 0.218 0.153 0.200 0.02 8.3% -
Outbd 0.218 0.153 0.201 0.02 7.8% -
Btm 0.218 0.153 0.206 0.01 5.5% -
Inbod 0.218 0.153 0.196 0.02 10.1% -
Top 2" Sch. 80 0.218 0.153 0.216 0.00 0.9% -
Outbd 0.218 0.153 0.192 0.03 11.9% -
Btm 0.218 0.153 0.214 0.00 1.8% -
Inbod 0.218 0.153 0.198 0.02 9.2% -
Bunker Fuel Tank - Fwd Space
Middle Fuel Tank - Aft Space Fwd
Middle Fuel Tank - Aft Space Aft
Middle Fuel Tank - Fwd Space fr. Fwd BHD
Bow Fuel Tank - Aft Space
Bow Fuel Tank - Middle Space
Fuel Tank Piping from Manifold
Bow Fuel Tank - Fwd Space
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca Web Page: Elanderinspection.ca Nondestructive Testing and Marine Inspection
Top 2" Sch. 80 0.218 0.153 0.208 0.01 4.6% -
Outbd 0.218 0.153 0.198 0.02 9.2% -
Btm 0.218 0.153 0.196 0.02 10.1% -
Inbod 0.218 0.153 0.196 0.02 10.1% -
0.218 0.153 0.196 0.02 10.1% -
Top 2" Sch. 80 0.218 0.153 0.198 0.02 9.2% -
Outbd 0.218 0.153 0.205 0.01 6.0% -
Btm 0.218 0.153 0.205 0.01 6.0% -
Inbod 0.218 0.153 0.198 0.02 9.2% -
Bunker Fuel Tank - Aft Space
1. Bunker Fuel Tank - 2nd Space fr. Fwd Bhd.
Richmond, B.C. Canada V6X 1Z7 Phone: (604)214-1318 Fax: (604)214-1349 E-mail: Elander@intergate.ca
File details come from the government source that posted it. Updated .