Medeia Megger Report 2023.pdf
PDF 111 KB Posted
- Solicitation number
- ADF&G FY27 RV Medeia Shipyard Services - Request for Information (RFI)
- Issued by
- Alaska
About this file
I appreciate your detailed instructions, but I'm unable to access or read the actual content of the file you've referenced. You've provided the file metadata (GovTribe ID and filename "Medeia Megger Report 2023.pdf"), but the actual document content was not included in your message for me to review and summarize.
To provide the comprehensive summary you've requested, please share the full text or content of the Medeia Megger Report 2023.pdf file, and I will immediately deliver a professional two-paragraph summary following your specified format and requirements.
View the file
Other files
Show all 49
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Transport Canada TP127E - 100kΩ to hull per TP127E 34.6 (b)
1.25 GΩ 1.36 GΩ
1.68 GΩ 1.71 GΩ
4.25 GΩ 4.55 GΩ
3.62 GΩ 3.82 GΩ
3.07 GΩ 3.68 GΩ
4.95 GΩ 46 kΩ
20 GΩ 12 GΩ 14 GΩ
26 GΩ 10.5 GΩ 12 GΩ
92.6 MΩ 4.2 GΩ 94.9 MΩ
6.3 GΩ 6.6 GΩ 6.1 GΩ
1.84 GΩ 2.24 GΩ
1.72 GΩ 1.83 GΩ
7.48 MΩ 7.51 MΩ
596 MΩ 658 MΩ
9 GΩ 11.5 GΩ
Comments
14 Hot H2O 2 15 Drill Press 16 Hot H2O 2
11 Spare
12 SBE
13 Work Bench Grinder
8 Top Air Compressor 9 Lower AC
10 Sewer Pump
4 Radio 5 Washing Machine
7 Bottom Air Compressor 6 Dryer
1 Void Room Lights 2 Auto Pilot 3 Radio
Description of test performed: 500V Megger Test Criteria:
Test Data Circuit #: Circuit Identification: Phase A or L1 Phase B or L2 Phase C
Location: Work Shop Voltage Rating: 120/208V 3ø
Calibration Cert #: 68346
Megger Test Certificate Panelboard Number or Name: Void Room
MARINE SERVICES DIVISION
Vessel: RV Medeia Client: Point Hope Maritime Work Item Number: 48640 Date: 2023-03-14 Test Technician: Matt Bolton Test Equipment: MIT430/2
All test equipment calibration certificates traceable to N.R.C. standards Megger Test Certificate
TSBC Licence #LEL0004514
2.75 GΩ 5.2 GΩ 3.61 GΩ
8.1 GΩ 9.7 GΩ 0.2 kΩ
7.8 GΩ 6.5 GΩ 1.3 GΩ
343 GΩ 16.5 GΩ 16.5 GΩ
3.1 GΩ 2.5 GΩ 4.4 GΩ
2.6 GΩ 1 GΩ 1.6 GΩ
6.6 GΩ 5.3 GΩ 10.5 GΩ
5.5 GΩ 3.8 GΩ 3.6 GΩ
1.25 GΩ 1.3 GΩ
7.4 kΩ 2.3 kΩ
630 MΩ 846 MΩ
1.02 GΩ 1.26 GΩ 1.25 GΩ
133 MΩ 120 MΩ
2.7 GΩ 3.5 GΩ 2.9 GΩ
1.03 GΩ 1.01 GΩ 2.48 GΩ
Vessel: RV Medeia Client: Point Hope Maritime Work Item Number: 48640
Panelboard Number or Name: P2
Date: 2023-03-14 Test Technician: Matt Bolton Test Equipment: MIT430/2 Calibration Cert #: 68346 MARINE SERVICES DIVISION
Megger Test Certificate
Test Data
Location: Engine Room Voltage Rating: 120/208V 3ø Description of test performed: 500V Megger
1 Main Deck Heat
Test Criteria:
Circuit #: Circuit Identification: Phase A or L1 Phase B or L2 Phase C
2 Freezer Hold Compressor 3 Port Blower 4 Engine Room Fan 5 Fish Hold Compressor 6 Fuel Pump 7 Fire Pump 8 Bilge Pump 9 Engine Room Battery Charger
10 Galley Stove 11 Racor Filter Pump 12 Fibreglass Box 13 Emergency Lights & Sump Pumps 14 110V Transformer 15 Fibreglass Box
Comments
All test equipment calibration certificates traceable to N.R.C. standards
1.02 GΩ 1.29 GΩ
7.1 MΩ 6.3 MΩ
1.85 GΩ 1.89 GΩ
5 GΩ 5 GΩ
7.9 GΩ 6.1 GΩ 4.7 GΩ
8.1 GΩ 3.5 GΩ 4.1 GΩ
3.89 GΩ 3.82 GΩ 3.85 GΩ
30 GΩ 35 GΩ 30 GΩ
4.2 GΩ 3.7 GΩ 4.1 GΩ
2.2 GΩ 1.56 GΩ
3.6 GΩ 3.8 GΩ
9 GΩ 6.4 GΩ
2.51 GΩ 2.75 GΩ
5.7 GΩ 6.8 GΩ
7.6 GΩ 7 GΩ
383 MΩ 407 MΩ
9.1 GΩ 8.8 GΩ
22 GΩ 29 GΩ
Vessel: RV Medeia Client: Point Hope Maritime Work Item Number: 48640
Panelboard Number or Name: P1
Date: 2023-03-14 Test Technician: Matt Bolton Test Equipment: MIT430/2 Calibration Cert #: 68346 MARINE SERVICES DIVISION
Megger Test Certificate
Test Data
Location: Engine Room Voltage Rating: 120/208V 3ø Description of test performed: 500V Megger
1 Port Engine Room Lights
Test Criteria:
Circuit #: Circuit Identification: Phase A or L1 Phase B or L2 Phase C
2 STBD Engine Room Lights 3 Fresh H2O Pump AFT
4 Fresh H2O Pump FWD 5 Steering Motor FWD 6 Steering Motor AFT 7 Wheelhouse Panel 8 Void Room Panel 9 Main Deck Panel
10 Steering Motor FWD 11 Racor Lights 12 Raw H2O Deck Pump 13 Head Pump 14 Freezer Hold Pump 15 Waste Oil Pump 16 Engine Room Heater STBD 17 Stack Lights 18 Engine Room Heater Port
Comments
All test equipment calibration certificates traceable to N.R.C. standards
1.51 GΩ 1.68 GΩ
2.9 GΩ 3.4 GΩ
3.4 GΩ 3.9 GΩ
3.45 GΩ 4.4 GΩ
806 MΩ 802 MΩ
3.53 GΩ 4.2 GΩ
1.7 GΩ 1.9 GΩ
0.14 MΩ 0.14 MΩ
93 MΩ 2.5 MΩ
3.1 GΩ 3 GΩ
2.5 GΩ 2.5 GΩ
360 MΩ 375 MΩ
3 GΩ 3.9 GΩ
3.7 GΩ 4.2 GΩ
2.5 GΩ 2.9 GΩ
0.14 MΩ 0.14 MΩ
101 MΩ 102 MΩ
891 MΩ 919 MΩ
1.69 GΩ 1.69 GΩ
Vessel: RV Medeia Client: Point Hope Maritime Work Item Number: 48640
Panelboard Number or Name: Galley
Date: 2023-03-14 Test Technician: Matt Bolton Test Equipment: MIT430/2 Calibration Cert #: 68346 MARINE SERVICES DIVISION
Megger Test Certificate
Test Data
Location: Main Deck Voltage Rating: 120/208V 3ø Description of test performed: 500V Megger
1 Port Head & Stairway
Test Criteria:
Circuit #: Circuit Identification: Phase A or L1 Phase B or L2 Phase C
2 STBD Head 3 Galley Center Receptacle 4 Galley Front Receptacle 5 Mess Hall Light Receptacle 6 Galley Rear Receptacle 7 TV/Coffee Receptacle 8 Fridge Freezer 9 Ice Maker & Trash Compactor
10 Galley Lights 11 Port Storage Room 12 STBD State Room & Pantry 13 Front Bunk Room Lamp 14 Constavolt 15 Front Bunk Room 16 Lower STBD Bunk Room 17 Lower Back Port Bunk Room & Hall 18 Bogen Amp & Door Alarm 19 Intercom
Comments
All test equipment calibration certificates traceable to N.R.C. standards
1.22 MΩ 8.2 GΩ
6.1 GΩ 2.1 MΩ
31.2 MΩ 7.9 GΩ
10 GΩ 408 MΩ
32 kΩ 1.02 GΩ
3.81 GΩ 3.75 GΩ
1.24 GΩ 1.2 GΩ
18 GΩ 18.5 GΩ
45 kΩ 45 kΩ
7.5 GΩ 14.5 GΩ
663 MΩ 620 MΩ
841 MΩ 897 MΩ
1 GΩ 1.9 GΩ
2.5 GΩ 2.9 GΩ
1.82 MΩ 1.82 MΩ
1.7 GΩ 1.8 GΩ
0.6 MΩ 0.6 MΩ
2.4 GΩ 2.5 GΩ
1.9 GΩ 2.3 GΩ
2.8 GΩ 3 GΩ
Vessel: RV Medeia Client: Point Hope Maritime Work Item Number: 48640
Panelboard Number or Name: Wheelhouse Panel
Date: 2023-03-14 Test Technician: Matt Bolton Test Equipment: MIT430/2 Calibration Cert #: 68346 MARINE SERVICES DIVISION
Megger Test Certificate
Test Data
Location: Wheelhouse Voltage Rating: 120/208V 3ø Description of test performed: 500V Megger
1 Port Spot
Test Criteria:
Circuit #: Circuit Identification: Phase A or L1 Phase B or L2 Phase C
2 STBD Spot 3 Upper Deck Lights 4 Lower Deck Lights 5 Navigation Panel 6 AFT Floods 7 Fathometer Loran 8 Window Defroster 9 Window Heater
10 Spare 11 Port Wheelhouse Receptacle 12 FWD & STBD O.L./Gen Alarm 13 Sonar CH12 14 Leniar 15 Wheelhouse Lights 16 Survey Room Lights 17 Survey Room Receptacle 18 Survey Room Receptacle 19 Survey Room Receptacle 20 Constavolt
Comments
All test equipment calibration certificates traceable to N.R.C. standards
5 GΩ 5.1 GΩ
6.1 GΩ 6.5 GΩ
4.2 GΩ 4.6 GΩ
38.9 MΩ 41.1 MΩ 42 MΩ
7.8 GΩ 7.7 GΩ 7.8 GΩ
8.1 GΩ 10 GΩ 13 GΩ
6.1 GΩ 7.8 GΩ 8.9 GΩ
17.5 GΩ 18.1 GΩ 19.3 GΩ
135 MΩ 135 MΩ 135 MΩ
5.6 GΩ 5.8 GΩ 6.1 GΩ
18.5 GΩ 19.1 GΩ 18.7 GΩ
21 GΩ 23 GΩ 24 GΩ
8.6 GΩ 9.3 GΩ 8.7 GΩ
4.9 GΩ 5.3 GΩ 5.7 GΩ
8.5 GΩ 8.9 GΩ 9.3 GΩ
9 GΩ 9.7 GΩ 10.5 GΩ
23 kΩ 32 kΩ 32 kΩ 23 kΩ
Vessel: RV Medeia Client: Point Hope Maritime Work Item Number: 48640
Panelboard Number or Name: Misc Loads
Date: 2023-03-14 Test Technician: Matt Bolton Test Equipment: MIT430/2 Calibration Cert #: 68346 MARINE SERVICES DIVISION
Megger Test Certificate
Test Data
Location: Engine Room and Void Room Voltage Rating: Assorted Description of test performed: 500V Megger
Hydraulic Pump
Test Criteria:
Circuit #: Circuit Identification: Phase A or L1 Phase B or L2 Phase C
AFT Salt Water Pump FWD Salt Water Pump
Port Engine Air Compressor Ships Bilge Pump
Engine Room Fan - Fast Engine Room Fan - Slow
Fuel Pump Keel Cooler Pump
Freezer Compressor Fire Pump
Sewage Pump Steering Pump 1 Steering Pump 1
Void Air Compressor - Upper Void Air Compressor - Lower
Center Bilge Pump STBD Center Bilge Pump Port
Sump Pumps STBD Sump Pumps Port
Comments
All test equipment calibration certificates traceable to N.R.C. standards
1.75 GΩ 1.81 GΩ 1.84 GΩ
2.32 MΩ 2.35 MΩ 2.33 MΩ
4.3 GΩ 4.4 GΩ 4.6 GΩ
6.9 GΩ 7.1 GΩ 7.4 GΩ
Vessel: RV Medeia Client: Point Hope Maritime Work Item Number: 48640
Panelboard Number or Name: Generators and Shore Power
Date: 2023-03-14 Test Technician: Matt Bolton Test Equipment: MIT430/2 Calibration Cert #: 68346 MARINE SERVICES DIVISION
Megger Test Certificate
Test Data
Location: Engine Room Voltage Rating: 120/208V 3ø Description of test performed: 500V Megger
1 Generator 1
Test Criteria:
Circuit #: Circuit Identification: Phase A or L1 Phase B or L2 Phase C
2 Generator 2
Shore Power Cable Shore Power Transformer
Comments
All test equipment calibration certificates traceable to N.R.C. standards