TE C 5-1-022 Fire Dampers 2019-04-16 (2).xlsx
XLSX spreadsheet 21 KB Posted
- Attached to
- Sources Sought: Total Maintenance Contract (TMC) – Rheinland-Pfalz, Germany (409th CSB TCC)
- Solicitation number
- W564KV26RA000
About this file
This is a technical specification document listing fire damper equipment and inspection requirements across multiple facilities in support of a Total Maintenance Contract (TMC) for Rheinland-Pfalz, Germany. The spreadsheet identifies 11 fire damper installations located at various facilities (HELISAT, KLEBER, LRMC, MIAD, ROB, WSA, SEMBACH) with a total quantity of 209 units. The dampers are sourced from multiple manufacturers including Wildeboer (model FK-90), MINIMAX, and several unknown manufacturers, distributed across facilities numbered 3374, 3209, 3210, 3212, 93203, 1407, 201, 260, 611, 166, and 216. Each damper installation is assigned a "SA" (Semi-Annual) visual inspection frequency and technical inspection frequency designation, establishing the maintenance cadence required for this equipment.
The related Sources Sought announcement (Solicitation W564KV26RA000) issued by the Department of the Army Materiel Command's Army Contracting Command seeks qualified contractors to perform comprehensive total maintenance services for the Rheinland-Pfalz Area of Responsibility. This pre-solicitation RFI is market research only and does not constitute a binding commitment to award. Interested parties must submit capability statements demonstrating relevant experience in total maintenance contracting under NAICS code 561210, along with feedback on the draft Performance Work Statement and technical exhibits. Respondents must provide company details, CAGE and UEI codes, SAM.gov registration confirmation, and documented past performance on similar maintenance contracts including contract numbers and scope of work.
View the file
Other files
Show 40 more
Latest 50 of 73 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| Description | Installation | Facility # | Manufacturer | Model | Quantity | Visual Inspection Frequency | Technical Inspection Frequency | |
| FIRE DAMPER | HELISAT | 3374 | UNKNOWN | 1 | SA | |||
| FIRE DAMPER | KLEBER | 3209 | UNKNOWN | 24 | SA | |||
| FIRE DAMPER | KLEBER | 3210 | UNKNOWN | 12 | SA | |||
| FIRE DAMPER | KLEBER | 3212 | UNKNOWN | 24 | SA | |||
| FIRE DAMPER | KLEBER | 93203 | UNKNOWN | 12 | SA | |||
| FIRE DAMPER | LRMC | 93802 | UNKNOWN | 11 | SA | |||
| FIRE DAMPER | MIAD | 1407 | UNKNOWN | 3 | SA | |||
| FIRE DAMPER | ROB | 201 | UNKNOWN | 22 | SA | |||
| FIRE DAMPER | ROB | 260 | UNKNOWN | 25 | SA | ǀ | ||
| FIRE DAMPER | WSA | 611 | Wildeboer | FK-90 | 35 | SA | ||
| FIRE DAMPER | SEMBACH | 166 | MINIMAX | 15 | SA | |||
| FIRE DAMPER | ROB | 216 | UNKNOWN | 25 | SA |
&12TE-C-5.1-022
FIRE DAMPER