TE C 5-1-019 Fire Prot Systems H2O.xlsx
XLSX spreadsheet 25 KB Posted
- Attached to
- Sources Sought: Total Maintenance Contract (TMC) – Rheinland-Pfalz, Germany (409th CSB TCC)
- Solicitation number
- W564KV26RA000
About this file
This is a fire protection systems inventory spreadsheet documenting equipment installed across multiple facilities in the Rheinland-Pfalz region of Germany. The spreadsheet contains detailed records of approximately 120+ fire protection assets across various military installations including MIAD, Daenner, Helisat, KAD, Landstuhl, Kleber, Panzer, Pulaski, ROB, and Sembach facilities. The systems include deluge fire suppression systems with water supply, wet fire suppression systems, sprinkler control systems, sprinkler systems, underground storage water ponds, and gas extinguishing systems. Equipment manufacturers represented include Grinnell-Hoffman, Wormald-Kopper, Minimax, Millitzer, Hekatron, Viking, and Ansul, with most systems operating on wet water-based suppression technology. Inspection frequencies are designated as either quarterly (Q), annual (A), or semi-annual (SA), with visual and technical inspection requirements documented for each system.
This inventory file directly supports the Sources Sought pre-solicitation (W564KV26RA000) for a Total Maintenance Contract (TMC) in the Rheinland-Pfalz area. The 409th CSB TCC is conducting market research to identify contractors capable of performing comprehensive maintenance services on this existing fire protection infrastructure. The detailed equipment specifications, quantities, manufacturers, and inspection requirements documented in this spreadsheet provide essential baseline data for potential contractors to understand the scope and complexity of the maintenance requirement before the formal RFP is issued. Interested contractors must submit capability statements demonstrating relevant experience with similar total maintenance contracts, provide CAGE codes and UEI registration, and confirm active SAM.gov registration under NAICS code 561210.
View the file
Other files
Show 40 more
Latest 50 of 73 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Fire Protection System
| Description | Installation | Facility # | Manufacturer | Model | Quantity | # of Spinkler heads | Type of System (Dry/Wet) | Capacity (Water/Other) | Visual Inspection Frequency | Technical Inspection Frequency |
| DELUGE FIRE SUPR SYSTEM, H2O | MIAD | 1565 | GRINNEL-HOFFMAN | UV DET/MLTG | 1 | Wet | Q | |||
| DELUGE FIRE SUPR SYSTEM, H2O | MIAD | 1566 | GRINNEL-HOFFMAN | UV DET/MLTG | 1 | Wet | Q | |||
| DELUGE H20 SUPPLY SYSTEM | MIAD | 1549 | TPS | DELUGE | 1 | Wet | Q | |||
| DELUGE H20 SUPPLY SYSTEM | MIAD | 1567 | GRINNEL-HOFFMAN | HEAT DET/MLT | 1 | Wet | Q |
| FIRE SUPPRESSION SYSTEM, H2O | DAENNER | 3109 | A. MILLITZER | E. RELIABLE | 1 | Wet | A |
| FIRE SUPPRESSION SYSTEM, H2O | HELISAT | 3361 | GRINNELL | F200 | 1 | Wet | Q |
| FIRE SUPPRESSION SYSTEM, H2O | HELISAT | 3373 | TOTAL WALTHER | K-FACTOR 80 | 1 | Wet | A |
| FIRE SUPPRESSION SYSTEM, H2O | KAD | 2213 | WORMALD-KOPPER. | G 483-0087 | 1 | Wet | A |
| FIRE SUPPRESSION SYSTEM, H2O | KAD | 2219 | WORMALD-KOPPER. | F-300 | 1 | Wet | A |
| FIRE SUPPRESSION SYSTEM, H2O | KAD | 2238 | WORMALD | F-300 | 1 | Wet | A |
| FIRE SUPPRESSION SYSTEM, H2O | KAD | 2239 | WORMALD-KOPPER. | 462 A | 1 | Wet | A |
| FIRE SUPPRESSION SYSTEM, H2O | KAD | 2288 | A.MILLITZER | 4E38540B | 1 | Wet | A |
| FIRE SUPPRESSION SYSTEM, H2O | KAD | 2292 | MINIMAX | G4820052 | 1 | Wet | A |
| FIRE SUPPRESSION SYSTEM, H2O | KAD | 2371 | SFH BAD GOLDES. | 2104 | 1 | Wet | A |
| FIRE SUPPRESSION SYSTEM, H2O | KAD | 2372 | SFH BAD GOLDES. | 4981 | 3 | Wet | A |
| FIRE SUPPRESSION SYSTEM, H2O | KLEBER | 3272 | VAG JUO | 4E-131-14 | 1 | Wet | A |
| FIRE SUPPRESSION SYSTEM, H2O | MIAD | 1314 | GRINNEL-HOFFMAN | 1 | Wet | Q | |
| FIRE SUPPRESSION SYSTEM, H2O | PANZER | 3000 | HEKATRON | 61 138 | 1 | Wet | A |
| FIRE SUPPRESSION SYSTEM, H2O | PULASKI | 2953 | 1 | Wet | A | ||
| FIRE SUPPRESSION SYSTEM, H2O | ROB | 292 | KAH | 7078B | 1 | Wet | Q |
| FIRE SUPPRESSION SYSTEM, H2O | ROB | 216 | HEUMACH | 1 | Q | ||
| FIRE SUPPRESSION SYSTEM, H2O | ROB | 164 | WINTERPUMPEN GMBH | SPECK 66/250 | 1 | SA | |
| FIRE SUPPRESSION SYSTEM, H2O | LANDSTUHL | 3703 | MINIMAX | MX1230, GasType 3MNovec 1230 | 1 | A |
| FIRE SUPR SYSTEM, WATER, 1 HD | LANDSTUHL | 3740 | WORMALD KOPPER | 461 A | 1 | Wet | Q |
| FIRE SUPR SYSTEM, WATER, 1 HD | LANDSTUHL | 3810 | SCHUESSLER&SOHN | GE42386E | 1 | Wet | Q |
| FIRE SUPR SYSTEM, WATER, 2 HD | LANDSTUHL | 3768 | MILLITZER | 320117 | 1 | Wet | Q |
| FIRE SUPR SYSTEM, WATER, 2 HD | LANDSTUHL | 3772 | MILLITZER | 785 MZ | 1 | Wet | Q |
| PUMP, FIRE SUPRESSION SYS, H2O | MIAD | 1277 | SPECK PUMP | 80525 | 1 | Q |
| SPRINKLER CONTROL SYSTEM | HELISAT | 3361 | CALANBAU | SUWZ 3830 | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | DAENNER | 3102 | MINIMAX | DN 80 DIMX | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | DAENNER | 3103 | MINIMAX | NAVNMXIRK | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | HELISAT | 3374 | MINIMAX | TAV-VMX-DN80 | 2 | Wet | Q | |||||
| SPRINKLER SYSTEM | HELISAT | 3384 | MINIMAX | TAVVMX-DN100 | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | HELISAT | 3387 | MINIMAX | FMZ 4100 | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | KLAUTERN | 1036 | MINIMAX | NAV-NMX/RK | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | KLAUTERN | 1036 | 1 | Wet | Q | |||||||
| SPRINKLER SYSTEM | KLEBER | 3203 | MINIMAX | FMZ 4100 | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | KLEBER | 3205 | WALTER SCHMITT | 1 | Wet | Q | ||||||
| SPRINKLER SYSTEM | KLEBER | 3211 | MINIMAX | FMZ 4100 | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | KLEBER | 3222 | MILLITZER | 1 | Q | |||||||
| SPRINKLER SYSTEM | KLEBER | 3232 | VIKING | MICROMATIC M | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | KLEBER | 3246 | MINIMAX | DN 80 DIMX | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | KLEBER | 93203 | GRINNEL-MINIMAX | F 200/K875 | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | LANDSTUL | 3780 | MINIMAX | NAV-NMX/RK | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | LANDSTUL | 93802 | MINIMAX | DN 80 DIMX | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | MIAD | 1210 | MINIMAX | FMZ 4100 | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | PANZER | 3004 | MINIMAX | FMZ 4100 | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | PANZER | 3029 | JAERSCH&WALTER | BMZ | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | PULASKI | 2950 | OPTIMUS | NAV DN150 | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | ROB | 163 | IBS | A567-01 | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | ROB | 164 | MINIMAX | FMZ 4100 | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | ROB | 200 | MINIMAX | ECON AQUA | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | ROB | 201 | IBS | 1 | Wet | Q | ||||||
| SPRINKLER SYSTEM | ROB | 231 | MINIMAX | NMX/RK DN100 | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | ROB | 235 | MINIMAX | NMX/RK DN100 | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | ROB | 240 | VIKING | J-2 | 1 | Wet | Q | |||||
| SPRINKLER SYSTEM | ROB | 375 | 3 | Wet | Q | |||||||
| SPRINKLER SYSTEM | SEMBACH | 88 | MINIMAX | 1 | Q | |||||||
| SPRINKLER SYSTEM | SEMBACH | 135 | 1 | Q | ||||||||
| SPRINKLER SYSTEM | SEMBACH | 141 | DORNHÖFER | Preussag Minimax | 1 | Q | ||||||
| UNDERGROUND STORAGE WATER PONDS | KAD | 2283 | 1 | A | ||||||||
| UNDERGROUND STORAGE WATER PONDS | KAD | 2311 | 1 | A | ||||||||
| UNDERGROUND STORAGE WATER PONDS | KAD | 2357 | 1 | A | ||||||||
| SPRINKLER SYSTEM | SEMBACH | 141 | HAARDT | WS 75 | 1 | Q | ||||||
| SPRINKLER SYSTEM | SEMBACH | 147 | SCHÜSSLER &SOHN | 1 | Q | |||||||
| SPRINKLER SYSTEM | SEMBACH | 172 | 1 | Q | ||||||||
| SPRINKLER SYSTEM | WSA | 611 | MINIMAX | 1 | Wet | Q | ||||||
| SPRINKLER SYSTEM | KAD | 2221 | MINIMAX | DPA FXV 150 125 | 1 | Wet | Q/SA | SUB | ǀ | |||
| UNDERGROUND STORAGE WATER PONDS | KAD | 2221 | SBB | 9.17 X12.07 m | 2 | TANKS | A | SUB | ǀ | |||
| FIRE SUPPRESSION SYSTEM, H2O | KAD | 2264 | MINIMAX | FMZ 5000 | 1 | HEADS MX3 SU k 80 | Wet | Q/SA | SUB | ǀ | ||
| FIRE SUPPRESSION SYSTEM, H2O | KAD | 2369 | MINIMAX | FMZ 5000 | 1 | HEADS MX3 SU k 80 | Wet | Q/SA | SUB | ǀ | ||
| FIRE SUPPRESSION SYSTEM, H2O | KAD | 2219 | MINIMAX | FMZ 5000 | 1 | HEADS MX3 SU k 80 | Wet | Q/SA | SUB | ǀ | ||
| FIRE SUPPRESSION SYSTEM, H2O | KAD | 2219 | MINIMAX | GAS EXTINGUISHING SYSTEM | 1 | 3 | GAS | Q/SA | SUB | ǀ | ||
| FIRE SUPPRESSION SYSTEM, H2O | LANDSTUHL | 3750 | unknown | 1 | Wet | Q | SUB | ǀ | ||||
| FIRE SUPPRESSION SYSTEM, H2O | ROB | 260 | unknown | 1 | Wet | Q | SUB | ǀ | ||||
| SPRINKLER SYSTEM | LANDSTUL | 3812 | 1 | Wet | Q | |||||||
| FIRE SUPPRESSION SYSTEM, H2O | MIAD | 1517 | 1 | Wet | Q | |||||||
| SPRINKLER SYSTEM | MIAD | 1553 | 1 | Wet | Q | |||||||
| SPRINKLER SYSTEM | MIAD | 1592 | 1 | Wet | Q | |||||||
| SPRINKLER SYSTEM | SEMBACH | 410 | ? | 1 | Q | |||||||
| SPRINKLER SYSTEM | KLEBER | 3224 | unknown | unknown | 1 | unknown | unknown | unknown | unknown | Q | ||
| SPRINKLER SYSTEM | LANDSTUHL | 3812 | unknown | unknown | 1 | unknown | unknown | unknown | unknown | Q | ||
| SPRINKLER SYSTEM | LANDSTUHL | 3851 | unknown | unknown | 1 | unknown | unknown | unknown | unknown | Q | ||
| SPRINKLER SYSTEM | LANDSTUHL | 98312 | unknown | unknown | 1 | unknown | unknown | unknown | unknown | Q | ||
| SPRINKLER SYSTEM | LANDSTUHL | 3819 | unknown | unknown | 1 | unknown | unknown | unknown | unknown | Q | ||
| SPRINKLER SYSTEM | PULASKI | 2895 | unknown | unknown | 1 | unknown | unknown | unknown | unknown | Q | ||
| SPRINKLER SYSTEM | PULASKI | 2901 | unknown | unknown | 1 | unknown | unknown | unknown | unknown | Q | ||
| SPRINKLER SYSTEM | SEMBACH | 83 | unknown | unknown | 1 | unknown | unknown | unknown | unknown | Q | ||
| SPRINKLER SYSTEM | SEMBACH | 66 | unknown | unknown | 1 | unknown | unknown | unknown | unknown | Q | ||
| FIRE SUPPRESSION SYSTEM, H2O | ROB | 261 | unknown | 1 | Wet | Q | ||||||
| FIRE SUPPRESSION SYSTEM, H2O | ROB | 111 | ANSUL | 1 | Wet | Q | ||||||
| FIRE SUPPRESSION SYSTEM, H2O | KAD | 2385 | GUARDIAN | 1 | Wet | Q | ||||||
| FIRE SUPPRESSION SYSTEM, H2O | KAD | 2389 | GUARDIAN | 1 | Wet | Q | ||||||
| FIRE SUPPRESSION SYSTEM, H2O | ROB | 261 | unknown | 1 | Wet | Q | ||||||
| SPRINKLER SYSTEM | LANDSTUL | 3812 | 1 | Wet | Q | |||||||
| FIRE SUPPRESSION SYSTEM, H2O | MIAD | 1517 | 1 | Wet | Q | |||||||
| SPRINKLER SYSTEM | MIAD | 1553 | 1 | Wet | Q | |||||||
| SPRINKLER SYSTEM | MIAD | 1592 | 1 | Wet | Q | |||||||
| FIRE SUPPRESSION SYSTEM | KAD | 2292 | Kidde/ Gamma Electronik | 1 | SA | |||||||
| SPRINKLER SYSTEM | SEMBACH | 109 | MINIMAX ? | 1 | Q | |||||||
| SPRINKLER SYSTEM | KLEBER | 3213 | MINIMAX ? | 1 | Wet | Q | ||||||
| SPRINKLER SYSTEM | KLEBER | 3224 | unknown | unknown | 1 | unknown | unknown | unknown | unknown | unknown | ||
| SPRINKLER SYSTEM | LANDSTUL | 3820 | 1 | Wet | Q | |||||||
| SPRINKLER SYSTEM | LANDSTUL | 3840 | 1 | Wet | Q | |||||||
| SPRINKLER SYSTEM | LANDSTUL | 3843 | 1 | Wet | Q | |||||||
| SPRINKLER SYSTEM | LANDSTUL | 3844 | 1 | Wet | Q | |||||||
| SPRINKLER SYSTEM | LANDSTUL | 3752 | 1 | Wet | Q | |||||||
| SPRINKLER SYSTEM | LANDSTUL | 93802 | MINIMAX | DN 80 DIMX | 1 | Wet | Q | |||||
| FIRE SUPPRESSION SYSTEM, H2O | LANDSTUHL | 3750 | unknown | 1 | Wet | Q | ||||||
| Sprinkler System | KAD | 2292 | Minimax | 2 | Q | |||||||
| Sprinkler System | KLEBER | 3213 | Minimax | FMZ 5000 | 1 | Q | ||||||
| Sprinkler System | LANDSTUHL | 3812 | Minimax | FMZ 4100 | 2 | Q | ||||||
| Fire Suppression System | MIESAU | 1517 | Euroline | 1 | Q | |||||||
| Sprinkler System | MIESAU | 1553 | Euroline | 1 | Q | |||||||
| Sprinkler System | MIESAU | 1592 | 0 | Q | ||||||||
| Sprinkler System | SEMBACH | 109 | Minimax | FMZ 5000 | 1 | Q |
&14TE C 5.1-019
&12Fire Protection Systems
Page &P of &N Updated by Vectrus 2015-12-30