This is a Technical Exhibit A (TE-A) Performance Requirements document for liquid waste pumping services at Fort Sill, detailing six key performance objectives and their associated standards. The requirements focus on three main service areas: grease interceptor pumping/cleaning, pit latrine servicing, and sand/oil/water interceptor maintenance. Each service area has two associated performance objectives - one for the cleaning/pumping operation and one for proper waste disposal.

The document specifies zero-deviation performance thresholds for all objectives, with oversight conducted through random COR sampling and customer feedback. Key requirements include removing 99% of oily sludge/grease from outside grease interceptors, complete removal of liquid/sediment from pit latrines, and removing 99% of grease/liquids/solids from sand/oil/water interceptors. All waste must be transported and disposed of at state-licensed facilities or designated locations in accordance with the PWS specifications. This TE-A is part of a broader solicitation (W9124L-25-B-0003) for Fort Sill Post Wide Pumping Services, which is structured as a small business set-aside with a base period starting April 1, 2025, plus four one-year options.

View the file

Other files

File Type Posted
Solicitation_W9124L25B0003_Pumping Services.pdf PDF
Attachment 7 Questions and Answers.pdf PDF
Solicitation_W9124L25B0003_Pumping Services.pdf PDF
Amendment 0005_W9124L25B0003_Pumping Services.pdf PDF
Solicitation_W9124L25B0003_Pumping Services.pdf PDF
0002) Amendment 0004_W9124L25B0003_Pumping Services.pdf PDF
Attachment 6 Questions and Answers.pdf PDF
Solicitation_W9124L25B0003_Pumping Services.pdf PDF
Amendment 0003_W9124L25B0003_Pumping Services.pdf PDF
Solicitation_W9124L25B0003_Pumping Services.pdf PDF
Amendment 0002_W9124L25B0003_Pumping Services.pdf PDF
Attachment 5 Questions and Answers.pdf PDF
Amendment 0001_W9124L25B0003_Pumping Services.pdf PDF
Solicitation_W9124L25B0003_Pumping Services.pdf PDF
Attachment 2 Wage Determination REV 25 12.23.2024.pdf PDF
Attachment 4 Questions and Answers.pdf PDF
TE-E Fort Sill -Cantonment Pumping Locations.pdf PDF
Solicitation_W9124L25B0003_Pumping Services.pdf PDF
TE-C Estimated Workload - Liquid Waste Pumping.xlsx XLSX spreadsheet
TE-B Liquid Waste Pumping Services Deliverables.xlsx XLSX spreadsheet
TE-G Hazardous Waste Management Plan.pdf PDF
TE-F Fort Sill Range-Pumping Locations 50k.pdf PDF
TE-D Liquid Waste Pumping Services Performance Task and Frequency.xlsx XLSX spreadsheet
Attachment 3 Contractor Visit Itinerary for Liquid Waste Pumping Contract.pdf PDF
Attachment 1_PWS.pdf PDF
Attachment 2 Wage Determination REV 24 07.22.2024.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Technical Exhibit A (FY25)
Performance Requirements
Liquid Waste Pumping Services
Item #Performance ObjectiveStandardPerformance ThresholdIncentive / Disincentive
1Pump/Clean outside grease interceptorsRemove/pump 99% of oily sludge, grease and lint after cleaning IAW PW paragraph 5.2.3.1Zero deviation from standardRandom sampling by the COR of scheduled sites for the reporting period and customer feedback.
2Properly dispose of waste from grease interceptorsTransport and dispose of all waste accumulated from Ft. Sill to a state licensed / permitted facility IAW PWS paragraph 5.2.3.1.2.Zero deviation from standardRandom sampling by the COR of scheduled sites for the reporting period and customer feedback.
3Pump/Clean Pit LatrinesRemove liquid, sediment and materials from the pit holding tank IAW PSW paragraph 5.2.3.2Zero deviation from standardRandom sampling by the COR of scheduled sites for the reporting period and customer feedback.
4Properly dispose of waste from Pit LatrinesTransport and dispose ofwasted to determined locations IAW PSW paragraph 5.2.3.2.2.Zero deviation from standardRandom sampling by the COR of scheduled sites for the reporting period and customer feedback.
5Pump/Clean Sand/Oil/Water InterceptorsRemove 99% of all grease, liquids, solids and sediment from interceptors IAW PWS paragraph 5.2.3.3.Zero deviation from standardRandom sampling by the COR of scheduled sites for the reporting period and customer feedback.
6Properly dispose of waste from Sand/oil/Water InterceptorsTransport and dispose of waste to determined location IAW 5.2.3.3.2.Zero deviation from standardRandom sampling by the COR of scheduled sites for the reporting period and customer feedback.

File details come from the government source that posted it. Updated .